Responds to 790427 & 0521 Ltrs Reporting Results of Seismic Reanalysis of Reactor Coolant Piping,Using Updated Version of Westdyn Code Which Uses Absolute Sum Technique.Issue Successfully Resolved.Forwards Safety Evaluation
ML14184A079
Person / Time
Site: Robinson 
Issue date: 05/22/1979
From: Schwencer A
Office of Nuclear Reactor Regulation
To: Jackie Jones
CAROLINA POWER & LIGHT CO.
Shared Package
ML14184A080 List:
References
NUDOCS 7907130167
Download: ML14184A079 (4)


Text

Docket No 12 2 979 Mr. J. A., Jones Senior Vice President Carol ina Power and Light Company 336 Fayetteville Street Raleigh, North Carolina 27602

Dear Mr. Jones:

This is in response to your letters of April 27 and May 21, 1979, wherein you reported the results of a recent seismic reanalysis of the reactor coolant piping at H. B. Robinson Unit No. 2 using an updated version of the WESTDYN code which uses an absolute sum technique.

On the basis that the reanalysis was conducted with both an approved method and acceptable results, we consider this matter resolved, and are closing out this action item.

A copy of our safety evaluation addressing this' matter is enclosed.

Sincerely, Original Signed By A. Schwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors Distribution

Enclosure:

Docket File 50-261 J. Buchanah Safety Evaluation NRC PDR I&E (3)

Local PDR R. Bosnak cc:

w/enclosure ORB#l Reading V. Noonan'i See next page NRR Reading V."Stello D. Eisenhut R. Vollmer B. Grimes W. Russell T. Carter A. Schwencer C. Trammell DSS D. Neighbors 7907 130 /

RBosnak*

P. Kre ze

  • SEE PREVIOUS YELLOW FOR CONCURRENCE 05/04/79 T

o5c D..........

DOR: R1.......... DDR.:EB DOR DOR:.S&P.)

. DQR..

URN elb JDN hoV..oonan Ac neer*

WTRuss 11*

LD DAT7 9

105/05/79 05

{79 05/07/79 5/09/79 05 7

D A

.6) 7 Rent wmuW 31 (o-76) amRu 02d0 U.8. OevaRN UNua PRNTINmG owrecI:

1970 -6 7ss

-174

Docket No. 50-261 Mr. J. A. Jones Senior V'ce President Carolina Pwer and Light Company 336 Fayettevi11e Street Raleigh,.North Carolina. 27602

Dear Mr. Jones:

This is in response to your letter of April 27, 1979, wherein you reported the results of a recent seismic reanalysis of the reactor coolant piping at H. B.\\Robinson Unt No. 2 using an updated version of the WESTDYN code-which\\uses an absolute sum technique.

On the basis that the reanaiwy-,is was-conducted with both an approved method and acceptable results<\\we consider this matter resolved, and are closing out this action/ite Sincerely, A. Sch encer, Chief Operating Reactors Branch No., 1 Division of Operating Reactors cc:

IE Region II DISTRIBUT/ION Docket 50-261 ORB #1 r/f NRC PDR' Local D RVo mer VNoenan ASchwencer.

DNeighbors CTRammell, CSParish JRBuchanan

-ri!.0RB... DOR0

.1....... DOR.:EB...

0R:QR 1.

SURNAMIO QMaR.

.1:4k$Q fbo VNoonan ASchwehceyu

'E(Eisenhut I....

Q......

DATh 5//9

/9

  • /

79 5/-5(.....

/ 7.

/9 O

N R

N.8

.n NIRE IlfRM A1R 19O761 ILRCM 020t

s. GOVERNaMENT PmeRNTIN oPIS:

1o780 20s - 769

REG&4 UNITED STATES 0

NUCLEAR REGULATORY COMMISSIONI WASHINGTON,0. C.2 0555 MAY 22 1979 Docket No, 50-261 Mr. J. A. Jones Senior Vice President Carolina Power and Light Company 336 Fayetteville Street Raleigh, North Carolina 27602

Dear Mr. Jones:

This is in response to your letters of April 27 and May 21, 1979, wherein you reported the results of a recent seismic reanalysis of the reactor coolant piping at H. B. Robinson Unit No. 2 using an updated version of the WESTDYN code which uses an absolute sum technique.

On the basis that the reanalysis was conducted with both an approved method and acceptable results, we consider this matter resolved, and are closing out this action item.

A copy of our safety evaluation addressing this matter is enclosed.

Sincerely, chwencer, Chief Operating Reactors Branch #1 Division of Operating Reactors

Enclosure:

Safety Evaluation cc: w/enclosure See next page

Mr. J. A. Jones Carolina Power and Light Company cc:

G.' F. Trowbridge, Esquire Shaw, Pittman, Potts and Trowbridge 1800 M Street, N.W.

Washington, D. C. 20036 Hartsville Memorial Library Home and Fifth Avenues Hartsville, South Carolina 29550 John F. Wolf, Esquire, Chairman 3409 Shepherd Street Chevy Chase, Maryland 20015 Dr. A. Dixon Callihan Union Carbide Corporation P. 0. Box Y Oak Ridge, Tennessee 37830 Dr. Richard F. Cole Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C. 20555 United States Nuclear Regulatory Commission Office of Inspection and Enforcement Region II 101 Marietta Street Suite 3100 Atlanta, Georgia 30303