ML14183A696
| ML14183A696 | |
| Person / Time | |
|---|---|
| Site: | Robinson |
| Issue date: | 09/29/1995 |
| From: | Mozafari B NRC (Affiliation Not Assigned) |
| To: | Hinnant C CAROLINA POWER & LIGHT CO. |
| References | |
| TAC-M69478, NUDOCS 9510040256 | |
| Download: ML14183A696 (4) | |
Text
1 UNITED STATES 0
NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 29, 1995 Mr. C. S. Hinnant, Vice President Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, South Carolina 29550
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION ON SEISMIC QUALIFICATION OF MECHANICAL AND ELECTRICAL EQUIPMENT AT THE H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 (TAC NO. M69478)
Dear Mr. Hinnant:
By letter dated June 30, 1995, Carolina Power & Light Company submitted a summary report for the H. B. Robinson Steam Electric Plant, Unit No. 2, related to Generic Letter (GL) 87-02, "Verification of Seismic Adequacy of Mechanical and Electrical Equipment in Operating Reactors, USI A-46."
During our review, we identified the need for additional information as indicated below:
- 1. You have indicated your intent to use the volume control tank, condensate storage tank, and the refueling water storage tank as cooling sources.
Indicate whether these are the only sources (seismic or non seismic).
List the volumes of these tanks, the expected cooling duration, and whether they are seismically qualified.
- 2. Provide a listing of established and tested procedures for all of the methods and paths for cooling stated in the submittal.
- 3. Indicate whether all the equipment listed in the safe-shutdown equipment list (SSEL) is seismically qualified. If not, identify specifically the portions of the indicated cooling sources that are seismically qualified.
This request for information was discussed with your staff during a brief teleconference on September 26, 1995.
Thus, we anticipate your response can be provided within 30 days.
9510040256 950929 0 F FL d
PDR ADOCK 05000261 P
2 -
September 29, 1995 This request affects nine or fewer respondents and, therefore, is not subject to the Office of Management and Budget review under P.L.96-511.
Sincerely, (Original Signed By)
Brenda Mozafari, Project Manager Project Directorate II-1 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation Docket No. 50-261 cc:
See next page Distribution Docket File PUBLIC PDII-1 RF S. Varga J. Zwolinski OGC R. Jones S. Brewer ACRS (4)
D. Verrelli, RH FILENAME -
G:\\ROBINSON\\ROB69478.RAI OFFICE LA:PDII-P
)
-P DI11,- 1._1 NAME EDunning on ozafari a
h is DATE 09,21/95 O
95 09[
95 COPY es No Yes No Yes_
OFFICIAL RECORD COPY
-2 This request affects nine or fewer respondents and, therefore, is not subject to the Office of Management and Budget review under P.L.96-511.
Sincerely, Brenda Mozafari, Project Manager Project Directorate II-1 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation Docket No. 50-261 cc:
See next page
Mr. C. S. Hinnant H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:
Mr. R. E. Jones Mr. Dayne H. Brown, Director General Counsel - Legal Department Department of Environmental, Carolina Power & Light Company Health and Natural Resources Post Office Box 1551 Division of Radiation Protection Raleigh, North Carolina 27602 Post Office Box 27687 Raleigh, North Carolina 27611-7687 Karen E. Long Assistant Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director Post Office Box 629 Public Staff - NCUC Raleigh, North Carolina 27602 Post Office Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Resident Inspector's Office Mr. Max Batavia, Chief H. B. Robinson Steam Electric Plant South Carolina Department of Health 2112 Old Camden Road Bureau of Radiological Health Hartsville, South Carolina 29550 and Environmental Control 2600 Bull Street Regional Administrator, Region II Columbia, South Carolina 29201 U.S. Nuclear Regulatory Commission 101 Marietta St., N.W., Ste. 2900 Mr. J. Cowan Atlanta, Georgia 30323 Manager Nuclear Services and Environmental Mr. Dale E. Young Support Department Plant General Manager Carolina Power & Light Company Carolina Power & Light Company Post Office Box 1551 - Mail 0HS7 H. B. Robinson Steam Electric Plant Raleigh, North Carolina 27602 3581 West Entrance Road Hartsville, South Carolina 29550 Public Service Commission State of South Carolina Post Office Drawer 11649 Columbia, South Carolina 29211 Mr. R. M. Krich Manager -
Regulatory Affairs Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 3581 West Entrance Road Hartsville, South Carolina 29550