6.13 HIGH RADOON AREA 6.13.1 In lieu of the "control device" or "alarm signal" required by paragraph 20.1601(a) of 10 CFR 20. each High Radiation Area in which the intensity of radiation is 1000 mRem/hr or less shall be barricaded and conspicuously posted as a High Radiation Area and
-entrance thereto shall be controlled by requiring issuance of a Radiation Work Permit (RWP).* Any individual or group of individuals permitted to enter such areas shall be provided with or accompanied by one or more of the following:
- a. A radiation monitoring device which continuously indicates the radiation dose rate in the area.
- b. A radiation monitoring device provided for each individual which continuously integrates the radiation dose rate in the area and alarms when a preset integrated dose is received.
Entry into such areas with this monitoring device may be made after the dose rate levels in the area have been established and personnel have been made knowledgeable of them.
- c.
An individual qualified in radiation protection procedures who is equipped with a radiation dose rate monitoring device. This individual shall be responsible for providing positive control over the activities within the area and shall perform periodic radiation surveillance at the frequency specified by the Radiation Control Supervisor in the Radiation Work Permit.
6.13.2 The requirements of 6.13.1 above shall also apply to each high radiation area in which the intensity of radiation is greater than 1000 mRem/hr at 30 centimeters (12 inches) from the radiation source or from any surface penetrated by the radiation. but less than 500 rads/hour at 1 meter from the radiation source or from any surface penetrated by the radiation. In addition. locked doors shall be provided to prevent unauthorized entry into such areas and the keys shall be maintained under the administrative control of the Operations Shift Supervisor on duty and/or the Radiation Control Supervisor. Entrance there to shall also be controlled by requiring issuance of a Radiation Work Permit. The footnote for Section 6.13.1 is not applicable to each high radiation area in which the intensity of radiation is greater than 1000 mRem/hr.
Health Physics personnel or personnel escorted by Health Physics personnel shall be exempt from the RWP issuance requirement during the performance of their assigned duties within the RCA. provided they comply with approved radiation protection procedures for entry into high radiation areas.
9501030182 941222 6.13-1 Amendment No.
PDR ADoCK 05000216 18,1,152 P
November 21, 1994 0
Mr. C. S. Hinnant, Vice President Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 Post Office Box 790 Hartsville, South Carolina 29551-0790
Dear Mr. Hinnant:
SUBJECT:
ISSUANCE OF AMENDMENT NO. 153 TO FACILITY OPERATING LICENSE NO.
DPR-23 REGARDING OPPOSITE TRAIN SURVEILLANCE TESTING REQUIREMENTS H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 (TAC NO. M89842)
The Nuclear Regulatory Commission has issued the enclosed Amendment No.153 to Facility Operating License No. DPR-23 for the H. B. Robinson Steam Electric Plant, Unit No. 2.
This amendment changes the Technical Specifications in response to your request dated June 29, 1994.
The amendment deletes the requirement to perform alternate train testing to demonstrate that other, similar, safety-related components are operable when components are found, or made, inoperable in the safety injection, residual heat removal, and containment spray systems.
The surveillance requirements, which the licensee refers to as accelerated testing requirements, affect the safety injection (SI) pumps, residual heat removal (RHR) pumps, containment spray (CS),
A copy of the related Safety Evaluation is enclosed.
Notice of Issuance will be included in the Commission's bi-weekly Federal Register notice.
Sincerely, Original signed by:
Brenda L. Mozafari, Project Manager Project Directorate II-1 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation Docket No. 50-261
Enclosures:
- 1. Amendment No. 153 to DPR-23
- 2. Safety Evaluation cc w/enclosures:
See next page DOCUMENT NAME:
G:\\ROBINSON\\ROB89842.AMD To receive a copy of this document, Indcate In the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE LA:PD21:DRPE E
PM:PD21:DRPE NRR:DOPS C D:PD21:DRPE OGC NAME PDAnderson I B~ozafari/rst 1 j CGrimes MBoyle:Acting I
DATE 10/,: /94 10/D0 /94 1 /2./94 1/
?,/94 1
94 OFFICIAL RECORD COPY
Mr. C. S. Hinnant H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:
Mr. R. E. Jones Mr. Dayne H. Brown, Director General Counsel - Legal Department Department of Environmental, Carolina Power & Light Company Health and Natural Resources Post Office Box 1551 Division of Radiation Protection Raleigh, North Carolina 27602 Post Office Box 27687 Raleigh, North Carolina 27611-7687 Karen E. Long Assistant Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director Post Office Box 629 Public Staff -
NCUC Raleigh, North Carolina 27602 Post Office Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Resident Inspector's Office Mr. Max Batavia, Chief H. B. Robinson Steam Electric Plant South Carolina Department of Health 2112 Old Camden Road Bureau of Radiological Health Hartsville, South Carolina 29550 and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Mr. H. W. Habermeyer, Jr.
101 Marietta St., N.W., Ste. 2900 Vice President Atlanta, Georgia 30323 Nuclear Services Department Carolina Power & Light Company Mr. Dale E. Young Post Office Box 1551 Plant General Manager Raleigh, North Carolina 27602 Carolina Power & Light Company H. B. Robinson Steam Electric Plant Hartsville Memorial Library 3581 West Entrance Road 147 West College Avenue Hartsville, South Carolina 29550 Hartsville, South Carolina 29550 Public Service Commission State of South Carolina Post Office Drawer 11649 Columbia, South Carolina 29211 Mr. R. M. Krich Manager - Regulatory Affairs Carolina Power & Light Company H. B. Robinson Steam Electric Plant, Unit No. 2 Post Office Box 790 Hartsville, South Carolina 29551-0790