ML14183A435

From kanterella
Jump to navigation Jump to search
Ack Response to NRC Re ECCS Evaluation Models Dealing W/Fuel Cladding Swelling & Incidence of Rupture. Response Acceptable & No Further Action Necessary
ML14183A435
Person / Time
Site: Robinson 
Issue date: 09/12/1980
From: Varga S
Office of Nuclear Reactor Regulation
To: Jackie Jones
Carolina Power & Light Co
References
NUDOCS 8010010164
Download: ML14183A435 (3)


Text

Docket No. 50-261 Mr.*J. A. Jones Senior Executive Vice President Carolina Power and Light Company 336 Fayetteville Street Raleigh, North Carolina 27602

Dear Mr. Jones:

We have reviewed your response to our November 9, 1979 letter concerning those portions of your ECCS evaluation models, dealing with fuel cladding swelling and incidence of rupture.

We find that you have adequately confirmed the representations made in your behalf by your fuel supplier. We, therefore, conclude that your response is acceptable and that no further action is necessary at this time.

Sincerely, Q1riginal signed b' S. A Varga Steven A. Varga, Chief Operating Reactors Branch 01 Division of Licensing cc:

See next page D0D.

O FFICEN SURNAME JDNe..

h gry b

.W g DATE

...9/

Q /8 8 - -

NRC FORM 318 (9 76) NRCM 0240

  • U.S.

GOVERNMENT PRINTING OFFICE: 1.979-289-369

0kp~

REG&

5 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 SEPTDGER 1 ' 1980 Docket No. 50-261 Mr. J. A. Jones Senior Executive Vice President Carolina Power and Light Company 336 Fayetteville Street Raleigh, North Carolina 27602

Dear Mr. Jones:

We have reviewed your response to our November 9, 1979 letter concerning those portions of your ECCS evaluation models, dealing with fuel cladding swelling and incidence of rupture.

We find that you have adequately confirmed the representations made in your behalf by your fuel supplier.

We, therefore, conclude that your response is acceptable and that no further action is necessary at this t i me.

Sincerely,

/ Levern A. ar

, Ch ef Operating Reactors ranch #1 Division of Licensi' cc:

See next page

Mr. J. A. Jones Carolina Power and Light Company cc: G. F. Trowbridge, Esouire Shaw, Pittman, Potts and Trowbridge 1800 M Street, N.W.

Washington, D. C. 20036 Hartsville Memorial Library Home and Fifth Avenues Hartsville, South Carolina 29550 Michael C. Farrar, Chairman Atomic Safety and Licensing Appeal Board Panel U. S. Nuclear Regulatory Comission Washington, D. C. 20555 Richard S. Salzman Atomic Safety and Licensing Appeal Board Panel U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Dr. W. Reed Johnson Atomic Safety and Licensing Appeal Board Panel U. S. Nuclear Regulatory Commission Washington, D. C. 20555