ML14176A767
| ML14176A767 | |
| Person / Time | |
|---|---|
| Site: | Robinson |
| Issue date: | 09/15/1989 |
| From: | Ebneter S NRC/IE, NRC/RGN-II |
| To: | Eury L Carolina Power & Light Co |
| Shared Package | |
| ML14176A768 | List: |
| References | |
| NUDOCS 8909270148 | |
| Download: ML14176A767 (4) | |
See also: IR 05000261/1989020
Text
ACCELERATED
DISTRIBUTION
DEMONSTRATION
SYS-TEM
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
WESSION NBR:8909270148
DOC.DATE: 89/09/15
NOTARIZED: NO
DOCKET #
FACIL:50-261 H.B. Robinson Plant, Unit 2, Carolina Power & Light C 05000261
AUTH.NAME
AUTHOR AFFILIATION
EBNETER,S.D.
Region 2, Ofc of the Director
RECIP.NAME
RECIPIENT AFFILIATION
EURY,L.W.
Carolina Power & Light Co.
SUBJECT: Forwards Insp Rept 50-261/89-20 on 890828-0901.No violations
noted.
DISTRIBUTION CODE: IE01D COPIES RECEIVED:LTR o
ENCL
SIZE: +
TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response
NOTES:
RECIPIENT
COPIES
RECIPIENT
COPIES
ID CODE/NAME
LTTR ENCL
ID CODE/NAME
LTTR ENCL
PD2-1 PD
1
1
LO,R
1
1
INTERNAL: AEOD
I
1
AEOD/DEIIB
1
1
AEOD/TPAD
1
1
DEDRO
1
1
NRR SHANKMAN,S
1
1
NRR/DEST DIR
1
1
NRR/DLPQ/PEB
1
1
NRR/DOEA DIR 11
1
1
NRR/DREP/EPB 10
1
1
NRR/DREP/RPB 10
2
2
NRR/PMAS/ILRB12
1
NUDOCS-ABSTRACT
1
1
OE LEBERM-AN,J
1
1
OGC/HDS1
1
1
RE
L
02
1
1
RES MORISSEAU,D
1
1
- -RGN2-FILE
01
1
1
RNAL: LPDR
1
1
NRC PDR
1
1
1
1
I
D
S
A
D
D
NorE TO ALL "RIDS" RECIPIENTS:
S
PLEASE
ELP US TO EUE JAST!
CNCT THE DOCUMENT CONTRL DESK,
ROCM P1-37 (EXT. 20079) TO ELIMIA
10tR NAM FcM DISTRIBUIC
W
TAL NUMBER b
W
p
U RWIT NE
ENCL
23
September 15, 1989
Docket No. 50-261
License No. DPR-23
Carolina Power and Light Company
ATTN:
Mr. Lynn W.. Eury
Executive Vice President
Power Supply
P. 0. Box 1551
Raleigh, NC 27602
Gentlemen:
,
SUBJECT: AUGMENTED INSPECTION TEAM REPORT REPORT NO. 50-261/89-20
This refers to the special, onsite inspection conducted by the NRC Augmented
Inspection Team (AIT) during the period August 28 - September 1, 1989.
The
inspection included a review of the events related to the identification of
inadequate net positive suction head for the Auxiliary Feedwater (AFW)
Pumps
at your H. B. Robinson facility.
At the conclusion of the inspection, the
findings were discussed with those members of your staff identified in the
enclosed inspection report.
The AIT concluded that- your lack of management attention to technical issues
and the resolution of those issues led to the late identification of this AFW
operability problem. This lack of management overview was compounded by the
following:
a lack of design basis information concerning the simultaneous
operation of three pumps;
the feeling that the
pumps were operable as
demonstrated by passing their surveillance tests; the non-prioritization of
your internal inspection findings; and the treating of the information as it
was developed at too low a level in your organization without management
involvement. Additionally, we are concerned with the apparent inability of
your implementing programs to promptly identify and elevate these types of
items to appropriate levels of management.
The enclosed copy of the AIT report identifies the areas examined during this
review. Within these areas, the inspection consisted of selective examinations
of procedures
and representative records,
interviews with personnel,
and
observation of activities in progress.
In accordance with Section 2.790 of the NRC's "Rules of Practice," Part 2,
Title 10, Code o.f Federal Regulations, a copy of this letter and its enclosure
will be placed in the NRC Public Document Room.
We appreciate your cooperation during our team inspection and subsequent
evaluation of this event.
Your
open discussion of your findings and
evaluations was very beneficial.
PDR ADOCK 05000261
Carolina Power and Light Company
2
September 15, 1989
Should you have any questions concerning this letter, please contact us.
Sincerely,
(ORIGINAL SIGNED BY S. D. EBNETER)
Stewart D. Ebneter
Regional Administrator
Enclosure:
AIT Inspection Report
cc w/encl:
C. R. Dietz, Manager
Robinson Nuclear Project Department
H. B. Robinson Steam Electric Plant
P. 0. Box 790
Hartsville, SC 29550
R. E. Morgan, Plant General Manager
H. B. Robinson Steam Electric Plant
P. 0. Box 790
Hartsville, SC 29550
Dayne H. Brown, Chief
Radiation Protection Branch
Division of Facility Services
N. C. Department of Human Resources
701 Barbour Drive
Raleigh, NC
27603-2008
McCuen Morrell, Chairman
Darlington County Board of Supervisors
County Courthouse
Darlington, SC 29535
D. E. Hollar
Associate General Counsel
Carolina Power and Light Company
P. 0. Box 1551
Raleigh, NC 27602
Richard E. Jones, General Counsel
Carolina Power and Light Company
P. 0. Box 1551
Raleigh, NC 27602
cc w/encl: (See page 3)
Carolina Power and Light Company
3
September 15, 1989
cc w/encl:
cont'd
H. A. Cole
Special Deputy Attorney General
State of North Carolina
P. 0. Box 629
Raleigh, NC 27602
Avery Upchurch, Chairman
Triangle J Council of Governments
100 Park Drive
P. 0. Box 12276
Research Triangle Park, NC 27709
Robert Gruber
Executive Director
Public Staff -
NCUC
P. 0. Box 29520
Raleigh, NC 27626-0520
State of South Carolina
bcc w/encl:
Document Control Desk
NRC Resident Inspector
U.S. Nuclear Regulatory Commission
Route 5, Box 413
Hartsville, SC
29550
RH
RI
S
RII:DRP
RII:DRP
PKe
ogg
TPeebles
WLevis
BBonser
09/JP/89
09/ 1/89
09/'-/
89
09/ /89
RIV
RII:D S
RII:DR9
RLo
WLafave
ershoff
DVer
11i
09/
/89
09/
/89
09///89
09/" 89