ML14176A679
| ML14176A679 | |
| Person / Time | |
|---|---|
| Site: | Robinson |
| Issue date: | 08/26/1981 |
| From: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | |
| Shared Package | |
| ML14176A676 | List: |
| References | |
| 50-261-81-22, NUDOCS 8110160409 | |
| Download: ML14176A679 (1) | |
Text
APPENDIX A NOTICE OF VIOLATION Carolina Power & Light Company Docket No. 50-261 H. B. Robinson 2 License No. DPR-23 As a result of the inspection conducted on July 11, 1981 through August 10, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980), the following violation was identified.
Technical Specification 6.8.1 requires that procedures be implemented that meet or exceed the requirements of Section 5.3 of ANSI 18.7-1972. The requirements of Section 5.3.9 of ANSI 18.7-1972 with regard to control of storage and preservation of materials and equipment to prevent damage or deterioration is implemented by Volume 21, Storeroom Procedure-3 of the Plant Operating Manual. This procedure requires that safety-related motors be stored in a heated, well-ventilated building to prevent condensation and corrosion and that the temperature be maintained between 400 and 1400F.
This procedure additionally requires that hazardous chemicals, paints, solvents and like materials be stored in well-ventilated areas not in close proximity to quality assurance review items.
Contrary to the above, as of July 16, 1981, the storage procedures had not been implemented in that the following were stored improperly:
(1) A spare safety-related service water pump motor-was stored in an area having no temperature control or monitoring systems and with the ventilation fan secured.
(2) Hazardous chemicals and flammable solvents were stored in an unventi lated building and in proximity to quality controlled hydrogen pero xide.
This is a Severity Level VI Violation (Supplement I.F.).
Pursuant to the provisions of 10 CFR 2.201, you are hereby required to submit to this office within thirty days of the date of this Notice, a written statement or explanation in reply, including: (1) admission or denial of the alleged viola tion; (2) the reasons for the violations if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved. Consideration may be given to extending your response time for good cause shown.
Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation.
The responses directed by this Notice are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.
.AUG 2 6 1981 Date: