ENCLOSURE 1 NOTICE OF VIOLATION Carolina Power and Light Company Docket No. 50-261 Robinson 2 License No. DPR-23 The following violation was identified during an inspection conducted on June 24 - 28, 1985. The Severity Level was assigned in accordance with the NRC Enforcement Policy (Title 10, Code of Federal Regulations Part 2, Appendix C).

Title 10 Code of Federal Regulations, Part 50.55a(g) requires that inservice testing, to verify operational readiness of pumps and valves whose function is required for safety, be accomplished in accordance with Section XI of the ASME Boiler and Pressure Vessel (B and PV)

Code.

ASME B and PV Code,Section XI, 1977 edition through Summer 1978 addenda, has been identified as the applicable code for inservice testing.

For a pump with a vibration amplitude of.86 mils, Table IWP-3100-2 of ASME B and PV Code,Section XI, specifies the following allowable ranges of test quantities:

Acceptable Range - zero to two mils, Alert Range - two to three mils, and Required Action Range - greater than three mils. Paragraph IWP-4120 of the ASME B and PV Code,Section XI, states that "the full-scale range of each instru ment shall be three times the reference value or less".

Contrary to the above, inservice testing of pumps and valves was not accomplished in accordance with the ASME B and PV Code,Section XI, in that the following was noted:

The allowable ranges of Test Quantities for the service water pump with a vibration amplitude of 0.86 mils, as specified in Carolina Power and Light Procedure OST-302, Revision 8, were:

Acceptable Range -

less than or equal to five mils, Alert Range - greater than five mils, but less than six mils, and Required Action Range - equal to or greater than six mils.

Seven gauges used in CP&L Procedure Nos. OST-251, OST-403 and OST 908 had range to pressure ratios of 3.85 to 8.85.

This is a Severity Level IV violation (Supplement I).

Pursuant to Title 10 Code of Federal Regulations Part 2.201, you are required to submit to this office within 30 days of the date of this Notice, a written statement or explanation in reply, including:

(1) admission or denial of the alleged violation; (2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the results achieved; (4) the corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.

8508080381 850717 PDR ADOCK 05000261 G

PDR

Carolina Power and Light Company 2

Docket No. 50-261 obinson 2 License No. DPR-23 Security or safeguards information should be submitted as an enclosure to facilitate withholding it from public disclosure as required by Title 10 Code of Federal Regulations Part 2.790(d) or Title 10 Code of Federal Regulations Part 73.21.

JUL 17 1985 Date: