Text
0G
UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION II
101 MARIETTA ST., N.W., SUITE 3100
ATLANTA, GEORGIA 30303
In Reply Refer To:
FEB 0 51997
RII:PJK
50-324/80-40, 50-325/80-43
-~5 261 7-TP
50-400/80-24,
50-401/80-22, 50-402/80-22,
50-403/80-22
Carolina Power and Light Company
ATTN:
J. A. Jones
Senior Executive Vice President and
Chief Operating Officer
411 Fayetteville Street
Raleigh, NC
27602
Gentlemen:
This refers to the meeting held at your corporate offices in Raleigh, North Carolina
on October 17,
1980,
at our request.
This meeting was related to activities autho
rized by NRC License Nos.
CPPR-158,
CPPR-159,
CPPR-160
and CPPR-161 for the Brunswick, Robinson and Harris facilities.
Our evaluation as developed from the Systematic Assessment of Licensee Performance
.
(SALP) was presented and discussed. The results of this evaluation are included
in the enclosed inspection report.
It is our opinion that this meeting was particularly beneficial in that we were
able to present our evaluation of your activities, and in turn, you were able to
respond directly to these evaluations.
Your positive response to the presentation is
appreciated and should enhance
communications with us in areas pertinent to safe reactor operations.
In
accordance with Section 2.790 of the NRC's "Rules of Practice," Part 2,
Title 10,
Code of Federal Regulation's,
a copy of this letter and the enclosed
inspection report will be placed in the NRC's Public Document Room.
No reply to this letter is
required; however,
should you have any questions
concerning these matters, we will be glad to discuss them with you.
Sincerely,
ames P. O'Reilly
rector
Enclosure:
(See Page 2)
810217805
FEB 05 1981
Carolina Power and Light Company
-2
Enclosure:
RII Report Nos. 50-324/80-40,
50-325/80-43, 50-261/80-31,
50-400/80-24, 50-401/80-22,
50-402/80-22, 50-403/80-22
cc w/encl:
A. C. Tollison, Jr., Plant Manager
R. B. Starkey, Jr., Plant Manager
R. M. Parsons, Site Manager