ML14175B102

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 790925-28
ML14175B102
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 10/18/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML14175B099 List:
References
50-261-79-22, NUDOCS 7912030079
Download: ML14175B102 (1)


Text

OCT 9 1979 APPENDIX A NOTICE OF VIOLATION Carolina Power and Light Company License No. DPR-23 H. B. Robinson Based on the NRC inspection September 25-28,

1979, certain of your activities were apparently not conducted in full compliance with NRC requirements as indi cated below. These items have been categorized as described in correspondence to you dated December 31, 1974.

As required by Technical Specification 6.8.1, written procedures shall be established, implemented and maintained that meet or exceed the requirements and recommendations of Section 5.1 and 5.3 of ANSI N18.7-1972 and Appendix A of USNRC Regulatory Guide 1.33 dated November 3, 1972.

ANSI N18.7-1972, Section 5.3.7, states in part that procedures shall be provided for the control, treatment, and management of radioactive wastes.

R.G. 1.33 (1972),

Appendix A, Section G, includes spent resin and filter sludge handling, baling machine operation, and drum handling and storage as typical safety related activities which should be covered by written procedures.

Contrary to the above, there were no licensee-approved written procedures for the methods and techniques routinely used to transfer and dewater spent resin or to solidfy evaporator bottoms.

This is an infraction.

7 9 1 2 0 30 7