ML14175B039

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 790226-0302
ML14175B039
Person / Time
Site: Robinson 
Issue date: 03/23/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML14175B036 List:
References
50-261-79-05, 50-261-79-5, NUDOCS 7905230614
Download: ML14175B039 (1)


Text

MAR 2 3 1979 APPENDIX A NOTICE OF VIOLATION Carolina Power and Light Company License No. DPR-23 H. B. Robinson 2 Based on the NRC inspection February 26 - March 2, 1979, certain of your activities were apparently not conducted in full compliance with NRC require ments as indicated below. These items have been categorized as described in correspondence to you dated December 31, 1974.

As required by Technical Specification 6.3.1, each member of the facility staff shall meet the minimum qualifications of ANSI N18.1-1971. Section 4.5.2 of ANSI N18.1 states, in part, that technicians in responsible positions shall have a minimum of two years of working experience in their specialty.

Contrary to the above, RC&T technicians who do not have a minimum of two years working experience in the health physics specialty have routinely been assigned as the only health physics representative on shift. The RC&T technicians on shift were in a responsible position in that they evaluated radiological hazards, specified protective controls, and approved radiation work permits.

This is an infraction.

7905 23061q