1 NRR-PMDAPEm Resource From:

Sreenivas, V Sent:

Friday, May 30, 2014 12:23 PM To:

'david.heacock@dom.com' Cc:

'david.sommers@dom.com'; Pascarelli, Robert; 'Gary D Miller'; Hoffman, Keith; Tom Shaub

Subject:

ACCEPTANCE REVIEW - Surry Unit 2 - Request for Alternative S2-I5-SPT-01 and Request to Use 2007E/2008A Section XI for Category B-L-1 Items (MF4129)

By letter dated May 7, 2014, Virginia Electric and Power Company submitted a relief requesting relief for alternative S2-I5-SPT-01 proposes an alternative to the Category B-P requirements for a VT-2 examination of the bottom of the Reactor Pressure Vessel during the system leakage test. This alternative is requested in accordance with 10 CFR 50.55a(a)(3)(ii). The request for a subsequent edition/addenda of Section XI seeks approval to utilize the 2007 Edition through the 2008 Addenda of ASME Section XI for Examination Category B-L-1. Pursuant to 10 CFR 50.55a(g)(4)(iv) and in accordance with the guidance of RIS 2004-12 the use of a subsequent ASME Code Edition and Addenda is being requested. The code of record for Surry Power Station Unit 2 fifth 10-year Inservice Inspection (ISI)

Interval is the ASME Section XI, 2004 Edition. The purpose of this email is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staffs acceptance review of this relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed exemption request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.

If you have any questions, please contact me at 301-415-2597.

V. Sreenivas, PH.D., C.P.M.,

North Anna and Surry Power Stations Project Manager, LPL2-1, Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

Hearing Identifier:

NRR_PMDA Email Number:

1320 Mail Envelope Properties (V.Sreenivas@nrc.gov20140530122200)

Subject:

ACCEPTANCE REVIEW - Surry Unit 2 - Request for Alternative S2-I5-SPT-01 and Request to Use 2007E/2008A Section XI for Category B-L-1 Items (MF4129)

Sent Date:

5/30/2014 12:22:51 PM Received Date:

5/30/2014 12:22:00 PM From:

Sreenivas, V Created By:

V.Sreenivas@nrc.gov Recipients:

"'david.sommers@dom.com'" <david.sommers@dom.com>

Tracking Status: None "Pascarelli, Robert" <Robert.Pascarelli@nrc.gov>

Tracking Status: None

"'Gary D Miller'" <gary.d.miller@dom.com>

Tracking Status: None "Hoffman, Keith" <Keith.Hoffman@nrc.gov>

Tracking Status: None "Tom Shaub" <tom.shaub@dom.com>

Tracking Status: None

"'david.heacock@dom.com'" <david.heacock@dom.com>

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 2427 5/30/2014 12:22:00 PM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: