/""\\1 Midwest Laboratory Reviewed and Approved MONTHLY PROGRESS REPORT RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM DAVIS-BESSE NUCLEAR POWER STATION OAK HARBOR, OHIO Reporting Period: January-December, 2013 Prepared and Submitted by ENVIRONMENTAL, INC.,
MIDWEST LABORATORY Project Number: 8003 Date _0,;:,.,2_-_I_;_Cf_-..;;..20--=-( lf.~.,__
Distribution: A Percival, Davis-Besse (2 copies and Original Raw Data)
TABLE OF CONTENTS Section Page List of Tables............................................................................................................... iii
1.0 INTRODUCTION
......................................................................................................... vi 2.0 LISTING OF MISSED SAMPLES................................................................................ vii 3.0 DATA TABULATIONS................................................................................................ viii Appendices A
Interlaboratory Comparison Program Results........................................................... A-1 B
Data Reporting Conventions..................................................................................... B-1 C
Supplemental Analyses............................................................................................ C-1 ii
LIST OF TABLES Airborne particulates and iodine collected at Location T-1, analyses for gross beta and iodine-131............................................................................................................. 1-1 2
Airborne particulates and iodine collected at Location T-2, analyses for gross beta and iodine-131............................................................................................................. 2-1 3
Airborne particulates and iodine collected at Location T-3, analyses for gross beta and iodine-131............................................................................................................. 3-1 4
Airborne particulates and iodine collected at Location T-4, analyses for gross beta and iodine-131............................................................................................................. 4-1 5
Airborne particulates and iodine collected at Location T-7, analyses for gross beta and iodine-131............................................................................................................. 6-1 6
Airborne particulates and iodine collected at Location T-8, analyses for gross beta and iodine-131............................................................................................................. 6-1 7
Airborne particulates and iodine collected at Location T-9, analyses for gross beta and iodine-131............................................................................................................. 7-1 8
Airborne particulates and iodine collected at Location T-11, analyses for gross beta and iodine-131............................................................................................................. 8-1 9
Airborne particulates and iodine collected at Location T-12, analyses for gross beta and iodine-131............................................................................................................. 9-1 10 Airborne particulates and iodine collected at Location T-27, analyses for gross beta and iodine-131........................................................................................................... 10-1 11 Airborne particulate data, gross beta analysis, monthly averages, minima and maxima...................................................................................................................... 11-1 12 Airborne particulate samples, quarterly composites by location, analyses for strontium-89, strontium-90 and gamma-emitting isotopes......................................... 12-1 13 Area monitors (TLD), quarterly................................................................................................. 13-1 14 Area monitors (TLD), annua1.................................................................................................... 14-1 15 Milk, analyses for strontium-89, strontium-90, iodine-131, gamma-emitting isotopes, calcium, stable potassium, and ratios of strontium-90 (pCi) per gram of calcium and cesium-137 (pCi) per gram of potassium................................................................................. 15-1 16 Ground water, analyses for gross beta, tritium, strontium-89 and strontium-90 and gamma-emitting isotopes, quarterly collections,...................................................................... 16-1 17 Domestic meat, analysis for gamma-emitting isotopes............................................................ 17-1 18 Wild meat, analysis for gamma-emitting isotopes.................................................................... 18-1 iii
LIST OF TABLES (continued) 19 Green leafy vegetable, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes......................................................................................................... 19-1 20 Fruit, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes.................................................................................................................................... 20-1 21 Animal-wildlife feed, analysis for gamma-emitting isotopes..................................................... 21-1 22 Soil, analysis for gamma-emitting isotopes.............................................................................. 22-1 23 Treated surface water, monthly composites of weekly grab samples, analysis for gross beta................................................................................................................................ 23-1 24 Treated surface water, quarterly composites of weekly grab samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes........................................... 24-1 25 Untreated surface water, monthly composites of weekly grab samples, analyses for gross beta, tritium and gamma-emitting isotopes.................................................................... 25-1 26 Untreated surface water, quarterly composites of weekly grab samples, analyses for strontium-89 and strontium-90................................................................................................. 26-1 27 Fish, analyses for gross beta and gamma-emitting isotopes................................................... 28-1 28 Shoreline sediment, analysis for gamma-emitting isotopes..................................................... 29-1 iv
LIST OF TABLES (continued}
The following tables are in the Appendices:
Appendix A Attachment A: Acceptance criteria for spiked samples.............................................................. A-2 A-1 Interlaboratory Comparison Program Results.......................................................................... A1-1 A-2 Interlaboratory Comparison Program Results, thermoluminescent dosimeters (TLDs)..................................................................................................... A2-1 A-3 Results of the analyses on in-house spiked samples.............................................................. A3-1 A-4 Results of the analyses on in-house "blank" samples.............................................................. A4-1 A-5 Results of the analyses on in-house "duplicate" samples........................................................ AS-1 A-6 Mixed Analyte Performance Evaluation Program (MAPEP)..................................................... A6-1 A-7 Environmental Resources Associates, Crosscheck Program Results (EML study replacement).............................................................................................................. A 7-1 Appendix B B-1 Data Reporting Conventions...................................................................................................... B-2 v
1.0 INTRODUCTION
The following constitutes the current 2013 Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Davis-Besse Nuclear Power Station in Oak Harbor, Ohio. Results of completed analyses are presented in the attached tables. Missing entries indicate analyses that are not yet completed.
All activities, except gross alpha and gross beta, are decay corrected to the time of collection.
All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.
vi
Sample Type Location 2.0 LISTING OF MISSED SAMPLES Expected Collection Date vii Reason
3.0 DATA TABULATIONS viii
Table 1. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.
Location: T-1 Units:
Collection: Continuous. weekly exchange.
Date Volume Date Volume Collected (m")
Gross Beta Collected (mo)
Gross Beta Required LLD 0.010 0.010 01-08-13 258 0.062 +/- 0.005 07-09-13 291 0.018 +/- 0.003 01-15-13 286 0.039 +/- 0.004 07-16-13 281 0.020 +/- 0.004 01-22-13 288 0.021 +/- 0.004 07-23-13 280 0.020 +/- 0.004 01-29-13 278 0.032 +/- 0.004 07-30-13 267 0.010 +/- 0.004 02-05-13 292 0.043 +/- 0.004 08-06-13 267 0.024 +/- 0.004 02-12-13 286 0.026 +/- 0.004 08-13-13 268 0.028 +/- 0.004 02-19-13 287 0.025 +/- 0.004 08-20-13 268 0.029 +/- 0.004 02-26-13 289 0.016 +/- 0.003 08-27-13 271 0.047 +/- 0.005 09-03-13 300 0.031 +/- 0.004 03-05-13 287 0.016 +/- 0.003 03-12-13 286 0.019 +/- 0.003 09-10-13 311 0.035 +/- 0.004 03-19-13 287 0.028 +/- 0.004 09-17-13 312 0.024 +/- 0.004 03-26-13 287 0.014 +/- 0.003 09-24-13 288 0.028 +/- 0.004 04-02-13 287 O.Q18 +/- 0.003 10-01-13 289 0.022 +/- 0.004 1st Quarter Mean +/- s.d.
0.028 +/- 0.014 3rd Quarter Mean +/- s.d.
0.026 +/- 0.009 04-09-13 280 0.024 +/- 0.004 10-08-13 289 0.023 +/- 0.004 04-16-13 274 0.011 +/- 0.003 10-15-13 290 0.024 +/- 0.004 04-23-13 300 0.019 +/- 0.003 10-22-13 289 0.026 +/- 0.004 04-30-13 310 0.026 +/- 0.004 10-29-13 290 O.Q15 +/- 0.003 05-07-13 282 0.016 +/- 0.004 11-05-13 289 0.039 +/- 0.004 05-14-13 279 0.016 +/- 0.003 11-12-13 294 0.030 +/- 0.004 05-21-13 282 0.024 +/- 0.004 11-19-13 288 0.022 +/- 0.003 05-28-13 278 0.020 +/- 0.004 11-26-13 290 0.024 +/- 0.003 12-03-13 280 0.039 +/- 0.004 06-04-13 281 0.018 +/- 0.004 06-11-13 280 0.020 +/- 0.004 12-10-13 288 0.043 +/- 0.004 06-18-13 280 0.025 +/- 0.004 12-17-13 290 0.049 +/- 0.005 06-25-13 280 0.029 +/- 0.004 12-23-13 248 0.030 +/- 0.004 07-02-13 281 0.019 +/- 0.004 12-30-13 288 0.041 +/- 0.004 2nd Quarter Mean+/- s.d.
0.021 +/- 0.005 4th Quarter Mean +/- s.d.
0.031 +/- 0.010 Cumulative Average 0.026 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.
1-1
Table 2. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a Location: T-2 Units:
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m5)
Gross Beta Collected (me)
Gross Beta Required LLD 0.010 0.010 01-08-13 237 0.063 +/- 0.006 07-09-13 286 0.020 +/- 0.004 01-15-13 283 0.038 +/- 0.004 07-16-13 290 0.020 +/- 0.003 01-22-13 285 0.032 +/- 0.004 07-23-13 286 0.025 +/- 0.004 01-29-13 280 0.032 +/- 0.004 07-30-13 285 0.010 +/- 0.003 02-05-13 289 0.044 +/- 0.004 08-06-13 286 0.020 +/- 0.004 02-12-13 283 0.030 +/- 0.004 08-13-13 287 0.024 +/- 0.004 02-19-13 284 0.019 +/-0.003 08-20-13 284 0.026 +/- 0.004 02-26-13 284 0.017 +/-0.003 08-27-13 285 0.043 +/- 0.005 09-03-13 286 0.032 +/- 0.004 03-05-13 284 0.018 +/- 0.003 03-12-13 283 0.017 +/- 0.003 09-10-13 286 0.036 +/- 0.004 03-19-13 284 0.025 +/- 0.004 09-17-13 301 0.027 +/- 0.004 03-26-13 284 0.015 +/- 0.003 09-24-13 277 0.029 +/- 0.004 04-02-13 284 0.017 +/- 0.003 10-01-13 285 0.023 +/- 0.004 1st Quarter Mean +/- s.d.
0.028 +/- 0.014 3rd Quarter Mean +/- s.d.
0.026 +/- 0.008 04-09-13 284 0.030 +/- 0.004 10-08-13 286 0.026 +/- 0.004 04-16-13 285 0.012 +/-0.003 10-15-13 294 0.022 +/- 0.004 04-23-13 284 0.019 +/- 0.003 10-22-13 286 0.031 +/- 0.004 04-30-13 284 0.027 +/- 0.004 10-29-13 287 0.016 +/- 0.003 05-07-13 336 0.023 +/- 0.003 11-05-13 285 0.035 +/- 0.004 05-14-13 286 0.016 +/- 0.003 11-12-13 301 0.027 +/- 0.004 05-21-13 357 0.025 +/- 0.003 11-19-13 291 0.023 +/- 0.004 05-28-13 283 0.020 +/- 0.004 11-26-13 284 0.023 +/- 0.003 12-03-13 284 0.037 +/- 0.004 06-04-13 300 0.019 +/- 0.003 06-11-13 285 0.018 +/- 0.004 12-10-13 283 0.042 +/- 0.004 06-18-13 286 0.026 +/- 0.004 12-17-13 284 0.046 +/- 0.005 06-25-13 286 0.030 +/- 0.004 12-23-13 242 0.024 +/- 0.004 07-02-13 291 0.016 +/- 0.004 12-30-13 282 0.040 +/- 0.004 2nd Quarter Mean +/- s.d.
0.022 +/- 0.006 4th Quarter Mean +/- s.d.
0.030 +/- 0.009 Cumulative Average 0.026 a lodine-131 concentrations are< 0.07 pCilm3 unless noted otherwise.
2-1
Table 3. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 Location: T-3 Units:
Collection: Continuous.
exchange.
Date Volume Date Volume Collected (m.J)
Gross Beta Collected (m.J)
Gross Beta Required LLD 0.010 01-08-13 244 0.071 +/- 0.006 07-09-13 361 0.022 +/- 0.003 01-15-13 284 0.039 +/- 0.004 07-16-13 257 0.021 +/- 0.004 01-22-13 287 0.031 +/- 0.004 07-23-13 286 0.022 +/- 0.004 01-29-13 284 0.032 +/- 0.004 07-30-13 285 0.016 +/- 0.004 02-05-13 292 0.040 +/- 0.004 08-06-13 286 0.022 +/- 0.004 02-12-13 285 0.029 +/- 0.004 08-13-13 287 0.025 +/- 0.004 02-19-13 293 0.024 +/- 0.003 08-20-13 284 0.026 +/- 0.004 02-26-13 285 0.015 +/- 0.003 08-27-13 285 0.033 +/- 0.004 09-03-13 286 0.031 +/- 0.004 03-05-13 284 0.016 +/- 0.003 03-12-13 285 0.020 +/- 0.003 09-10-13 286 0.030 +/- 0.004 03-19-13 286 0.030 +/- 0.004 09-i?-13 294 0.023 +/- 0.004 03-26-13 290 0.017 +/- 0.003 09-24-13 278 0.024 +/- 0.004 04-02-13 286 0.018 +/- 0.003 i0-01-13 285 0.025 +/- 0.004 1st Quarter Mean +/- s.d.
0.029 +/- 0.015 3rd Quarter Mean +/- s.d.
0.025 +/- 0.005 04-09-13 285 0.027 +/- 0.004 10-08-13 285 0.023 +/- 0.004 04-16-13 271 0.013 +/- 0.003 10-15-13 285 0.020 +/- 0.004 04-23-13 283 0.020 +/- 0.004 10-22-13 283 0.030 +/- 0.004 04-30-13 283 0.029 +/- 0.004 10-29-13 284 O.Qi 3 +/- 0.003 05-07-13 277 0.016 +/- 0.004 1 1-05-13 284 0.033 +/- 0.004 05-14-13 280 0.016 +/- 0.003 11-12-13 287 0.030 +/- 0.004 05-21-13 282 0.024 +/- 0.004 11-19-13 282 0.024 +/- 0.004 05-28-13 277 0.006 +/- 0.003 1 1-26-13 286 0.027 +/- 0.004 12-03-13 283 0.047 +/- 0.005 06-04-13 282 0.018 +/- 0.004 06-11-13 284 0.018 +/- 0.004 12-10-13 283 0.046 +/- 0.004 06-18-13 286 0.024 +/- 0.004 12-17-13 284 0.049 +/- 0.005 06-25-13 286 0.026 +/- 0.004 12-23-13 242 0.027 +/- 0.004 07-02-13 295 0.015 +/- 0.003 12-30-13 282 0.038 +/- 0.004 2nd Quarter Mean +/- s.d.
0.019 +/- 0.006 4th Quarter Mean+/- s.d.
0.031 +/- 0.011 Cumulative Average 0.026 a lodine-131 concentrations are< 0.07 pCi!m3 unless noted otherwise.
3-1
Table 4. Airborne particulates and charcoal canisters. analyses for gross beta and iodine-131 8
Location: T-4 Units:
Collection: Continuous. weekly exchange.
Date Volume Date Volume Collected (mo)
Gross Beta Collected (mj)
Gross Beta Reguired LLD 0.010 0.010 01-08-13 245 0.069 +/- 0.006 07-09-13 285 0.022 +/- 0.004 01-15-13 282 0.040 +/- 0.004 07-16-13 287 0.018 +/- 0.003 01-22-13 280 0.030 +/- 0.004 07-23-13 287 0.026 +/- 0.004 01-29-13 274 0.036 +/- 0.004 07-30-13 284 0.008 +/- 0.003 02-05-13 289 0.037 +/- 0.004 08-06-13 285 0.022 +/- 0.004 02-12-13 285 0.033 +/- 0.004 08-13-13 285 0.019 +/- 0.004 02-19-13 286 0.025 +/- 0.004 08-20-13 283 0.025 +/- 0.004 02-26-13 285 0.015 +/- 0.003 08-27-13 284 0.040 +/- 0.005 09-03-13 285 0.032 +/- 0.004 03-05-13 285 0.016 +/- 0.003 03-12-13 285 0.018 +/- 0.003 09-10-13 285 0.032 +/- 0.004 03-19-13 286 0.027 +/- 0.004 09-17-13 292 0.025 +/- 0.004 03-26-13 286 0.016 +/- 0.003 09-24-13 277 0.029 +/- 0.004 04-02-13 286 0.018 +/- 0.003 10-01-13 284 0.025 +/- 0.004 1st Quarter Mean+/- s.d.
0.029 +/- 0.015 3rd Quarter Mean+/- s.d.
0.025 +/- 0.008 04-09-13 285 0.028 +/- 0.004 10-08-13 284 0.026 +/- 0.004 04-16-13 287 0.012 +/- 0.003 10-15-13 285 0.022 +/- 0.004 04-23-13 285 0.024 +/- 0.004 10-22-13 284 0.028 +/- 0.004 04-30-13 285 0.029 +/- 0.004 10-29-13 285 0.015 +/- 0.003 05-07-13 287 0.017 +/-0.004 11-05-13 285 0.041 +/- 0.004 05-14-13 285 0.016 +/- 0.003 11-12-13 288 0.032 +/- 0.004 05-21-13 288 0.023 +/- 0.004 11-19-13 283 0.024 +/- 0.004 05-28-13 283 0.012 +/- 0.003 11-26-13 287 0.025 +/- 0.004 12-03-13 282 0.043 +/- 0.004 06-04-13 288 0.020 +/- 0.004 06-11-13 284 0.018 +/- 0.004 12-10-13 284 0.042 +/- 0.004 06-18-13 286 0.024 +/- 0.004 12-17-13 289 0.042 +/- 0.004 06-25-13 286 0.027 +/- 0.004 12-23-13 243 0.029 +/- 0.004 07-02-13 286 0.016 +/- 0.004 12-30-13 283 0.044 +/- 0.004 2nd Quarter Mean +/- s.d.
0.020 +/- 0.006 4th Quarter Mean+/- s.d.
0.032 +/- 0.010 Cumulative Average 0.027 a lodine-131 concentrations are< 0.07 pCi!m3 unless noted otherwise.
4-1
Table 5. Airborne particulates and charcoal canisters. analyses for gross beta and iodine-131 3
Location: T-7 Units:
Collection: Continuous. weekly exchange.
Date Volume Date Volume Collected (rn3)
Gross Beta Collected (rn3)
Gross Beta 0.010 0.010 01-08-13 250 0.066 +/- 0.006 07-09-13 284 0.019 +/- 0.004 01-15-13 287 0.040 +/- 0.004 07-16-13 291 0.020 +/- 0.003 01-22-13 293 0.029 +/- 0.004 07-23-13 283 0.024 +/- 0.004 01-29-13 293 0.037 +/- 0.004 07-30-13 284 0.014 +/- 0.004 02-05-13 287 0.038 +/- 0.004 08-06-13 284 0.022 +/- 0.004 02-12-13 287 0.027 +/- 0.004 08-13-13 284 0.027 +/- 0.004 02-19-13 293 0.021 +/- 0.003 08-20-13 284 0.025 +/- 0.004 02-26-13 287 0.016 +/- 0.003 08-27-13 284 0.038 +/- 0.004 09-03-13 284 0.032 +/- 0.004 03-05-13 287 0.016 +/- 0.003 03-12-13 286 0.017 +/- 0.003 09-10-13 289 0.034 +/- 0.004 03-19-13 288 0.026 +/- 0.004 09-17-13 278 0.027 +/- 0.004 03-26-13 287 0.016 +/- 0.003 09-24-13 284 0.025 +/- 0.004 04-02-13 288 0.016 +/- 0.003 10-01-13 284 0.025 +/- 0.004 1st Quarter Mean +/- s.d.
0.028 +/- 0.014 3rd Quarter Mean +/- s.d.
0.026 +/- 0.006 04-09-13 287 0.025 +/- 0.004 10-08-13 283 0.023 +/- 0.004 04-16-13 280 0.014 +/- 0.003 10-15-13 289 0.022 +/- 0.004 04-23-13 280 0.020 +/- 0.004 10-22-13 278 0.030 +/- 0.004 04-30-13 280 0.026 +/- 0.004 10-29-13 283 0.015 +/- 0.003 05-07-13 280 0.015 +/- 0.004 11-05-13 283 0.033 +/- 0.004 05-14-13 280 0.012 +/- 0.003 11-12-13 284 0.032 +/- 0.004 05-21-13 266 0.025 +/- 0.004 11-19-13 283 0.022 +/- 0.004 05-28-13 283 0.013 +/- 0.003 11-26-13 284 0.024 +/- 0.004 12-03-13 284 0.040 +/- 0.004 06-04-13 284 0.020 +/- 0.004 06-11-13 284 0.018 +/- 0.004 12-10-13 283 0.048 +/- 0.004 06-18-13 284 0.026 +/- 0.004 12-17-13 294 0.049 +/- 0.005 06-25-13 284 0.027 +/- 0.004 12-23-13 244 0.031 +/- 0.004 07-02-13 284 0.018 +/- 0.004 12-30-13 286 0.046 +/- 0.004 2nd Quarter Mean +/- s.d.
0.020 +/- 0.005 4th Quarter Mean +/- s.d.
0.032 +/- 0.011 Cumulative Average 0.026 a lodine-131 concentrations are< 0.07 pCi!m3 unless noted otherwise.
5-1
Table 6 Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8
Location: T-8 Units:
Collection: Continuous, exchange.
Date Volume Date Volume Collected (m2)
Gross Beta Collected (m3)
Gross Beta Required LLD 01-08-13 246 0.069 +/- 0.006 07-09-13 284 0.019 +/- 0.004 01-15-13 287 0.041 +/- 0.004 07-16-13 285 0.018 +/- 0.003 01-22-13 288 0.029 +/- 0.004 07-23-13 280 0.020 +/- 0.004 01-29-13 280 0.034 +/- 0.004 07-30-13 281 0.013 +/- 0.003 02-05-13 288 0.043 +/- 0.004 08-06-13 281 0.021 +/- 0.004 02-12-13 287 0.033 +/- 0.004 08-13-13 282 0.026 +/- 0.004 02-19-13 288 0.025 +/- 0.004 08-20-13 280 0.024 +/- 0.004 02-26-13 287 0.014 +/- 0.003 08-27-13 282 0.040 +/- 0.005 09-03-13 281 0.034 +/- 0.004 03-05-13 288 0.016 +/- 0.003 03-12-13 270 0.016 +/- 0.003 09-10-13 286 0.032 +/- 0.004 03-19-13 284 0.027 +/- 0.004 09-17-13 279 0.025 +/- 0.004 03-26-13 284 0.018 +/- 0.003 09-24-13 281 0.027 +/- 0.004 04-02-13 285 0.015 +/- 0.003 10-01-13 280 0.025 +/- 0.004 1st Quarter Mean +/- s.d.
0.029 +/- 0.015 3rd Quarter Mean +/- s.d.
0.025 +/- 0.007 04-09-13 283 0.029 +/- 0.004 10-08-13
?R1 0.025 +/- 0.004 04-16-13 284 0.012 +/- 0.003 10-15-13 291 0.023 +/- 0.004 04-23-13 284 0.023 +/- 0.004 10-22-13 276 0.029 +/- 0.004 04-30-13 284 0.028 +/- 0.004 10-29-13 275 0.016 +/- 0.004 05-07-13 284 0.019 +/-0.004 11-05-13 281 0.037 +/- 0.004 05-14-13 284 0.017 +/- 0.003 11-12-13 337 0.025 +/- 0.003 05-21-13 284 0.025 +/- 0.004 11-19-13 283 0.024 +/- 0.004 05-28-13 284 0.012 +/- 0.003 11-26-13 284 0.023 +/- 0.004 12-03-13 284 0.043 +/- 0.004 06-04-13 283 0.017 +/- 0.004 06-11-13 284 0.018 +/- 0.004 12-10-13 284 0.043 +/- 0.004 06-18-13 284 0.025 +/- 0.004 12-17-13 284 0.041 +/- 0.004 06-25-13 284 0.029 +/- 0.004 12-23-13 242 0.029 +/- 0.004 07-02-13 284 0.012 +/- 0.003 12-30-13 288 0.039 +/- 0.004 2nd Quarter Mean +/- s.d.
0.020 +/- 0.006 4th Quarter Mean +/- s.d.
0.031 +/- 0.009 Cumulative Average 0.026 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.
6-1
Table 7. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 Location: T-9 Units:
Collection: Continuous.
exchange.
Date Volume Date Volume Collected (m5)
Gross Beta Collected (m:o)
Gross Beta Required LLD 0.010 0.010 01-08-13 241 0.069 +/- 0.006 07-09-13 278 0.022 +/- 0.004 01-15-13 270 0.041 +/- 0.004 07-16-13 284 0.018 +/- 0.003 01-22-13 281 0.029 +/- 0.004 07-23-13 286 0.026 +/- 0.004 01-29-13 277 0.032 +/- 0.004 07-30-13 275 0.013 +/- 0.004 02-05-13 281 0.044 +/- 0.004 08-06-13 286 0.021 +/- 0.004 02-12-13 290 0.031 +/- 0.004 08-13-13 287 0.026 +/- 0.004 02-19-13 267 0.027 +/- 0.004 08-20-13 285 0.029 +/- 0.004 02-26-13 280 0.018 +/- 0.003 08-27-13 294 0.043 +/- 0.005 09-03-13 278 0.030 +/- 0.004 03-05-13 290 0.019 +/- 0.003 03-12-13 270 0.020 +/- 0.004 09-10-13 291 0.038 +/- 0.004 03-19-13 277 0.031 +/- 0.004 09-17-13 288 0.024 +/- 0.004 03-26-13 273 0.020 +/- 0.004 09-24-13 168 0.040 +/- 0.006 04-02-13 299 0.018 +/- 0.003 10-01-13 295 0.024 +/- 0.004 1st Quarter Mean +/- s.d.
0.031 +/- 0.014 3rd Quarter Mean+/- s.d.
0.027 +/- 0.009 04-09-13 280 0.030 +/- 0.004 10-08-13 286 0.027 +/- 0.004 04-16-13 285 0.014 +/- 0.003 10-15-13 287 0.021 +/- 0.004 04-23-13 289 0.020 +/- 0.003 10-22-13 283 0.029 +/- 0.004 04-30-13 289 0.027 +/- 0.004 10-29-13 281 0.018 +/- 0.004 05-07-13 289 0.017 +/- 0.004 11-05-13 300 0.042 +/- 0.004 05-14-13 300 0.015 +/- 0.003 11-12-13 317 0.028 +/- 0.004 05-21-13 280 0.026 +/- 0.004 11-19-13 286 0.025 +/- 0.004 05-28-13 295 0.012 +/- 0.003 11-26-13 287 0.028 +/- 0.004 12-03-13 293 0.048 +/- 0.004 06-04-13 294 0.020 +/- 0.004 06-11-13 278 0.023 +/- 0.004 12-10-13 295 0.043 +/- 0.004 06-18-13 290 0.025 +/- 0.004 12-17-13 287 0.045 +/- 0.004 06-25-13 299 0.029 +/- 0.004 12-23-13 234 0.027 +/- 0.004 07-02-13 279 0.015 +/- 0.004 12-30-13 286 0.043 +/- 0.004 2nd Quarter Mean +/- s.d.
0.021 +/- 0.006 4th Quarter Mean +/- s.d.
0.033 +/- 0.010 Cumulative Average 0.028 lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.
7-1
Table 8. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131.
Location: T-11 Units:
Collection: Continuous. weekly exchange.
Date Volume Date Volume Collected (mj)
Gross Beta Collected (mo)
Gross Beta Required LLD 0.010 0.010 01-08-13 231 0.069 +/- 0.006 07-09-13 289 0.021 +/- 0.004 01-15-13 284 0.050 +/- 0.005 07-16-13 298 0.021 +/- 0.003 01-22-13 285 0.030 +/- 0.004 07-23-13 289 0.023 +/- 0.004 01-29-13 272 0.034 +/- 0.004 07-30-13 289 0.012 +/- 0.003 02-05-13 279 0.043 +/- 0.004 08-06-13 289 0.024 +/- 0.004 02-12-13 284 0.031 +/- 0.004 08-13-13 290 0.026 +/- 0.004 02-19-13 272 0.021 +/- 0.004 08-20-13 288 0.027 +/- 0.004 02-26-13 282 0.016 +/- 0.003 08-27-13 290 0.044 +/- 0.005 09-03-13 289 0.030 +/- 0.004 03-05-13 284 0.018 +/- 0.003 03-12-13 283 0.019 +/- 0.003 09-10-13 283 0.036 +/- 0.004 03-19-13 284 0.029 +/- 0.004 09-17-13 282 0.024 +/- 0.004 03-26-13 272 0.016 +/- 0.004 09-24-13 285 0.031 +/- 0.004 04-02-13 289 0.016 +/- 0.003 10-01-13 284 0.027 +/- 0.004 1st Quarter Mean +/- s.d.
0.030 +/- 0.016 3rd Quarter Mean +/- s.d.
0.027 +/- 0.008 04-09-13 289 0.029 +/- 0.004 10-08-13 285 0.027 +/- 0.004 04-16-13 289 0.017 +/- 0.003 10-15-13 284 0.020 +/- 0.004 04-23-13 289 0.023 +/- 0.004 10-22-13 284 0.027 +/- 0.004 04-30-13 289 0.034 +/- 0.004 10-29-13 284 0.016 +/- 0.003 05-07-13 289 0.018 +/- 0.004 11-05-13 285 0.035 +/- 0.004 05-14-13 289 0.016 +/- 0.003 11-12-13 281 0.029 +/- 0.004 05-21-13 290 0.026 +/- 0.004 11-19-13 284 0.026 +/- 0.004 05-28-13 288 0.012 +/- 0.003 11-26-13 284 0.023 +/- 0.003 12-03-13 281 0.047 +/- 0.005 06-04-13 289 0.018 +/- 0.003 06-11-13 289 0.018 +/- 0.003 12-10-13 284 0.048 +/- 0.004 06-18-13 289 0.019 +/- 0.004 12-17-13 285 0.052 +/- 0.005 06-25-13 289 0.029 +/- 0.004 12-23-13 243 0.026 +/- 0.004 07-02-13 281 0.017 +/- 0.004 12-30-13 284 0.043 +/- 0.004 2nd Quarter Mean +/- s.d.
0.021 +/- 0.006 4th Quarter Mean +/- s.d.
0.032 +/- 0.012 Cumulative Average 0.028 a lodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise.
8-1
Table 9. Airborne particulates and charcoal canisters. analyses for gross beta and iodine-131 a Location T-12 (C)
Units:
Collection: Continuous, Date Volume Date Volume Collected (m")
Gross Beta Collected (mJ)
Gross Beta 0.010 0.010 01-08-13 249 0.067 +/- 0.006 07-09-13 287 0.021 +/- 0.004 01-15-13 283 0.040 +/- 0.004 07-16-13 273 0.020 +/- 0.004 01-22-13 288 0.029 +/- 0.004 07-23-13 285 0.026 +/- 0.004 01-29-13 284 0.029 +/- 0.004 07-30-13 288 om2 +/- o.oo3 02-05-13 297 0.040 +/- 0.004 08-06-13 286 0.025 +/- 0.004 02-12-13 284 0.030 +/- 0.004 08-13-13 284 0.029 +/- 0.004 02-19-13 286 0.023 +/- 0.003 08-20-13 287 0.030 +/- 0.004 02-26-13 286 0.018 +/- 0.003 08-27-13 283 0.040 +/- 0.005 09-03-13 296 0.029 +/- 0.004 03-05-13 285 0.017 +/- 0.003 03-12-13 286 0.013 +/- 0.003 09-10-13 292 0.036 +/- 0.004 03-19-13 287 0.028 +/- 0.004 09-17-13 286 0.025 +/- 0.004 03-26-13 286 0.016 +/- 0.003 09-24-13 284 0.027 +/- 0.004 04-02-13 285 0.019 +/- 0.003 10-01-13 285 0.025 +/- 0.004 1st Quarter Mean +/- s.d.
0.028 +/- 0.014 3rd Quarter Mean +/- s.d.
0.027 +/- 0.007 04-09-13 287 0.027 +/- 0.004 10-08-13 285 0.028 +/- 0.004 04-16-13 285 0.013 +/- 0.003 10-15-13 290 0.019 +/- 0.004 04-23-13 286 0.018 +/- 0.003 10-22-13 289 0.027 +/- 0.004 04-30-13 286 0.025 +/- 0.004 10-29-13 292 0.017 +/- 0.003 05-07-13 229 0.015 +/- 0.004 11-05-13 289 0.034 +/- 0.004 05-14-13 284 0.017 +/- 0.003 11-12-13 288 0.029 +/- 0.004 05-21-13 288 0.026 +/- 0.004 11-19-13 287 0.024 +/- 0.004 05-28-13 282 0.017 +/- 0.004 11-26-13 293 0.023 +/- 0.003 12-03-13 288 0.046 +/- 0.004 06-04-13 299 0.018 +/- 0.003 06-11-13 285 0.021 +/- 0.004 12-10-13 287 0.042 +/- 0.004 06-18-13 283 0.027 +/- 0.004 12-17-13 292 0.047 +/- 0.004 06-25-13 287 0.029 +/- 0.004 12-23-13 248 0.026 +/- 0.004 07-02-13 288 0.015 +/- 0.004 12-30-13 286 0.042 +/- 0.004 2nd Quarter Mean +/- s.d.
0.021 +/- 0.005 4th Quarter Mean +/- s.d.
0.031 +/- 0.010 Cumulative Average 0.027 a lodine-131 concentrations are< 0.07 pCi!m3 unless noted otherwise.
9-1
Table 10. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a Location T -27 Units:
Collection: Continuous. weekly exchange.
Date Volume Date Volume Collected (mj)
Gross Beta Collected (mj)
Gross Beta Required LLD 0.010 0.010 01-08-13 243 0.068 +/- 0.006 07-09-13 282 0.021 +/- 0.004 01-15-13 274 0.045 +/- 0.005 07-16-13 278 0.020 +/- 0.004 01-22-13 285 0.030 +/- 0.004 07-23-13 280 0.024 +/- 0.004 01-29-13 275 0.035 +/- 0.004 07-30-13 280 0.013 +/- 0.004 02-05-13 289 0.043 +/- 0.004 08-06-13 283 0.022 +/- 0.004 02-12-13 280 0.032 +/- 0.004 08-13-13 279 0.025 +/- 0.004 02-19-13 282 0.025 +/- 0.004 08-20-13 290 0.031 +/- 0.004 02-26-13 282 0.015 +/- 0.003 08-27-13 278 0.038 +/- 0.005 09-03-13 286 0.030 +/- 0.004 03-05-13 281 0.020 +/- 0.003 03-12-13 282 0.019 +/- 0.003 09-10-13 281 0.035 +/- 0.004 03-19-13 286 0.029 +/- 0.004 09-17-13 278 0.025 +/- 0.004 03-26-13 283 0.016 +/- 0.003 09-24-13 276 0.027 +/- 0.004 04-02-13 280 0.019 +/- 0.004 10-01-13 286 0.024 +/- 0.004 1st Quarter Mean+/- s.d.
0.030 +/- 0.015 3rd Quarter Mean +/- s.d.
0.026 +/- 0.007 04-09-13 292 0.027 +/- 0.004 10-08-13 276 0.028 +/- 0.004 04-16-13 288 0.011 +/- 0.003 10-15-13 287 0.024 +/- 0.004 04-23-13 264 0.023 +/- 0.004 10-22-13 282 0.028 +/- 0.004 04-30-13 270 0.028 +/- 0.004 10-29-13 294 0.017 +/- 0.003 05-07-13 282 0.019 +/- 0.004 11-05-13 288 0.041 +/- 0.004 05-14-13 285 0.017 +/- 0.003 11-12-13 294 0.031 +/- 0.004 05-21-13 289 0.025 +/- 0.004 11-19-13 280 0.026 +/- 0.004 05-28-13 279 0.013 +/- 0.004 11-26-13 279 0.026 +/- 0.004 12-03-13 289 0.043 +/- 0.004 06-04-13 287 0.020 +/- 0.004 06-11-13 292 0.019 +/- 0.003 12-10-13 280 0.048 +/- 0.004 06-18-13 281 0.024 +/- 0.004 12-17-13 291 0.043 +/- 0.004 06-25-13 292 0.031 +/- 0.004 12-23-13 239 0.027 +/- 0.004 07-02-13 288 0.017 +/- 0.004 12-30-13 281 0.041 +/- 0.004 2nd Quarter Mean +/- s.d.
0.021 +/- 0.006 4th Quarter Mean +/- s.d.
0.033 +/- 0.009 Cumulative Average 0.027 a lodine-131 concentrations are< 0.07 pCi!m3 unless noted otherwise.
10- 1
Table 11-1. Airborne particulate data,gross beta analyses, monthly averages, minima and maxima.
Januar:t April Location Average Minima Maxima Location Average Minima Maxima T-9 0.043 0.029 0.069 T-9 0.023 0.014 0.03 T-11 0.046 0.030 0.069 T-11 0.026 0.017 0.034 T-12 0.041 0.029 0.067 T-12 0.021 0.013 0.027 T-27 0.045 0.030 0.068 T-27 0.022 0.011 0.028 Controls 0.044 0.029 0.069 Controls 0.023 0.011 0.034 T-1 0.039 0.021 0.062 T-1 0.020 0.011 0.026 T-2 0.041 0.032 0.063 T-2 0.022 0.012 0.030 T-3 0.043 0.031 0.071 T-3 0.022 0.013 0.029 T-4 0.044 0.030 0.069 T-4 0.023 0.012 0.029 T-7 0.043 0.029 0.066 T-7 0.021 0.014 0.026 T~8 0.043 0.029 0.069 T-8 0.023 0.012 0.029 Indicators 0.042 0.021 0.071 Indicators 0.022 0.011 0.030 Februar:t Ma Location Average Minima Maxima Location Average Minima Maxima T-9 0.030 0.018 0.044 T-9 0.018 0.012 0.026 T-11 0.028 0.016 0.043 T-11 0.018 0.012 0.026 T-12 0.028 0.018 0.040 T-12 0.019 0.015 0.026 T-27 0.029 0.015 0.043 T-27 0.019 0.013 0.025 Controls 0.029 0.015 0.044 Controls 0.019 0.012 0.026 T-1 0.028 0.016 0.043 T-1 0.019 0.016 0.024 T-2 0.028 0.017 0.044 T-2 0.021 0.016 0.025 T-3 0.027 0.015 0.040 T-3 0.016 0.006 0.024 T-4 0.028 0.015 0.037 T-4 0.017 0.012 0.023 T-7 0.026 0.016 0.038 T-7 0.016 0.012 0.025 T-8 0.029 0.014 0.043 T-8 0.018 0.012 0.025 Indicators 0.028 0.014 0.044 Indicators 0.018 0.006 0.025 March June Location Average Minima Maxima Location Average Minima Maxima T-9 0.022 0.018 0.031 T-9 0.022 0.015 0.029 T-11 0.020 0.016 0.029 T-11 0.020 0.017 0.029 T-12 0.019 0.013 0.028 T-12 0.022 0.015 0.029 T-27 0.021 0.016 0.029 T-27 0.022 0.017 0.031 Controls 0.021 0.013 0.031 Controls 0.022 0.015 0.031 T-1 0.019 0.014 0.028 T-1 0.022 0.018 0.029 T-2 0.018 0.015 0.025 T-2 0.022 0.016 0.030 T-3 0.020 0.016 0.030 T-3 0.020 0.015 0.026 T-4 0.019 0.016 0.027 T-4 0.021 0.016 0.027 T-7 0.018 0.016 0.026 T-7 0.022 0.018 0.027 T-8 0.018 0.015 0.027 T-8 0.020 0.012 0.029 Indicators 0.019 0.014 0.030 Indicators 0.021 0.012 0.030 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
11-1
Table 11-1. Airborne particulate data,gross beta analyses, monthly averages, minima and maxima.
October Location Average Minima Maxima Location Average Minima Maxima T-9 0.020 0.013 0.026 T-9 0.024 0.018 0.029 T-11 0.019 0.012 0.023 T-11 0.023 0.016 0.027 T-12 0.020 0.012 0.026 T-12 0.023 0.017 0.028 T-27 0.020 0.013 0.024 T-27 0.024 0.017 0.028 Controls 0.020 0.012 0.026 Controls 0.024 0.016 0.029 T-1 0.017 0.010 0.020 T-1 0.022 0.015 0.026 T-2 0.019 0.010 0.025 T-2 0.024 0.016 0.031 T-3 0.020 0.016 0.022 T-3 0.022 0.013 0.030 T-4 0.019 0.008 0.026 T-4 0.023 0.015 0.028 T-7 0.019 0.014 0.024 T-7 0.023 0.015 0.030 T-8 0.018 0.013 0.020 T-8 0.023 0.016 0.029 Indicators 0.019 0.008 0.026 Indicators 0.023 0.013 0.031 Au ust November Location Average Minima Maxima Location Average Minima Maxima T-9 0.030 0.021 0.043 T-9 0.034 0.025 0.048 T-11 0.030 0.024 0.044 T-11 0.032 0.023 0.047 T-12 0.031 0.025 0.040 T-12 0.031 0.023 0.046 T-27 0.029 0.022 0.038 T-27 0.033 0.026 0.043 Controls 0.030 0.021 0.044 Controls 0.033 0.023 0.048 T-1 0.032 0.024 0.047 T-1 0.031 0.022 0.039 T-2 0.029 0.020 0.043 T-2 0.029 0.023 0.037 T-3 0.027 0.022 0.033 T-3 0.032 0.024 0.047 T-4 0.028 0.019 0.040 T-4 0.033 0.024 0.043 T-7 0.029 0.022 0.038 T-7 0.030 0.022 0.040 T-8 0.029 0.021 0.040 T-8 0.030 0.023 0.043 Indicators 0.029 0.019 0.047 Indicators 0.031 0.022 0.047 September December Location Average Minima Maxima Location Average Minima Maxima T-9 0.032 0.024 0.040 T-9 0.040 0.027 0.045 T-11 0.030 0.024 0.036 T-11 0.042 0.026 0.052 T-12 0.028 0.025 0.036 T-12 0.039 0.026 0.047 T-27 0.028 0.024 0.035 T-27 0.040 0.027 0.048 Controls 0.030 0.024 0.040 Controls 0.040 0.026 0.052 T-1 0.027 0.022 0.035 T-1 0.041 0.030 0.049 T-2 0.029 0.023 0.036 T-2 0.038 0.024 0.046 T-3 0.026 0.023 0.030 T-3 0.040 0.027 0.049 T-4 0.028 0.025 0.032 T-4 0.039 0.029 0.044 T-7 0.028 0.025 0.034 T-7 0.044 0.031 0.049 T-8 0.027 0.025 0.032 T-8 0.038 0.029 0.043 Indicators 0.028 0.022 0.036 Indicators 0.040 0.024 0.049 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
11-2
Table 12.
Airborne particulates. analyses for strontium-89. strontium-90 and gamma-emitting isotopes.
Location Quarter Lab Code Volume (m3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterly Composite Units: pCi/m 3 1st Quarter TAP-1954 3698
< 0.0006
< 0.0004 2nd Quarter TAP-4053 3687
< 0.0006
< 0.0004 0.072 +/- 0.015 0.090 +/- 0.016
< 0.027
< 0.021
< 0.0008
< 0.0010
< 0.0009
< 0.0018
< 0.0011
< 0.0016
< 0.0084
< 0.0094
< 0.0007
< 0.0007
< 0.0007
< 0.0007
< 0.0015
< 0.0018
< 0.0042
< 0.0058 1st Quarter 2nd Quarter TAP-1955 TAP-4054 3644 3847
< 0.0007
< 0.0005
< 0.0005
< 0.0003 0.086 +/- 0.021 0.095 +/- 0.014
< 0.029
< 0.015
< 0.0024
< 0.0009
< 0.0021
< 0.0012
< 0.0015
< 0.0007
< 0.0070
< 0.0058
< 0.0013
< 0.0007
< 0.0011
< 0.0006
< 0.0019
< 0.0013
< 0.0033
< 0.0024 12-1 T-1 3rd Quarter 4th Quarter TAP-6350 TAP-7831 3693 3713
< 0.0005
< 0.0005
< 0.0004
< 0.0004 0.087 +/- 0.016 0.063 +/- 0.015
< 0.024
< 0.027
< 0.0009
< 0.0012
< 0.0007
< 0.0017
< 0.0008
< 0.0008
< 0.0079
< 0.0076
< 0.0010
< 0.0009
< 0.0010
< 0.0009
< 0.0009
< 0.0014
< 0.0049
< 0.0057 T-2 3rd Quarter 4th Quarter TAP-6351 TAP-7832 3724 3689
< 0.0006
< 0.0005
< 0.0004
< 0.0003 0.073 +/- 0.014 0.055 +/- 0.013
< 0.024
< 0.018
< 0.0007
< 0.0010
< 0.0007
< 0.0016
< 0.0011
< 0.0008
< 0.0081
< 0.0041
< 0.0009
< 0.0008
< 0.0005
< 0.0007
< 0.0018
< 0.0017
< 0.0021
< 0.0030
Table 12.
Airborne particulates, analyses for strontium-89. strontium-90 and gamma-emitting isotopes.
Location Quarter Lab Code Volume (m3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterly Composite Units: pCi/m 3 1st Quarter TAP-1956 3685
< 0.0006
< 0.0004 2nd Quarter TAP-4055 3671
< 0.0005
< 0.0004 0.078 +/- 0.017 0.096 +/- 0.017
< 0.024
< 0.022
< 0.0023
< 0.0009
< 0.0020
< 0.0013
< 0.0013
< 0.0008
< 0.0056
< 0.0051
< 0.0011
< 0.0009
< 0.0010
< 0.0008
< 0.0015
< 0.0011
< 0.0042
< 0.0035 1st Quarter 2nd Quarter TAP-1957 TAP-4056 3654 3715
< 0.0005
< 0.0007
< 0.0004
< 0.0005 0.062 +/- 0.014 0.094 +/- 0.015
< 0.022
< 0.022
< 0.0007
< 0.0010
< 0.0019
< 0.0014
< 0.0010
< 0.0013
< 0.0063
< 0.0080
< 0.0008
< 0.0008
< 0.0005
< 0.0009
< 0.0012
< 0.0017
< 0.0034
< 0.0060 12-2 T-3 3rd Quarter 4th Quarter TAP-6352 TAP-7833 3760 3650
< 0.0005
< 0.0005
< 0.0003
< 0.0004 0.087 +/- 0.018 0.057 +/- 0.016
< 0.024
< 0.026
< 0.0010
< 0.0014
< 0.0012
< 0.0024
< 0.0007
< 0.0010
< 0.0066
< 0.0096
< 0.0007
< 0.0011
< 0.0006
< 0.0011
< 0.0009
< 0.0021
< 0.0036
< 0.0040 T-4 3rd Quarter 4th Quarter TAP-6353 TAP-7834 3703 3662
< 0.0005
< 0.0005
< 0.0003
< 0.0004 0.087 +/- 0.014 0.079 +/- 0.019
< 0.024
< 0.020
< 0.0008
< 0.0008
< 0.0015
< 0.0015
< 0.0008
< 0.0010
< 0.0079
< 0.0099
< 0.0008
< 0.0011
< 0.0004
< 0.0011
< 0.0019
< 0.0011
< 0.0044
< 0.0051
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Location Quarter Lab Code Volume (m:;)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterly Composite Units: pCi/m3 1st Quarter TAP-1958 3713
< 0.0005
< 0.0004 2nd Quarter TAP-4057 3656
< 0.0005
< 0.0004 0.069 +/- 0.015 0.094 +/- 0.015
< 0.027
< 0.022
< 0.0009
< 0.0010
< 0.0007
< 0.0020
< 0.0007
< 0.0010
< 0.0054
< 0.0051
< 0.0003
< 0.0005
< 0.0003
< 0.0010
< 0.0014
< 0.0011
< 0.0038
< 0.0048 1st Quarter 2nd Quarter TAP-1959 TAP-4058 3662 3690
< 0.0006
< 0.0006
< 0.0005
< 0.0004 0.056 +/- 0.013 0.096 +/- 0.015
< 0.016
< 0.021
< 0.0008
< 0.0008
< 0.0010
< 0.0008
< 0.0010
< 0.0009
< 0.0050
< 0.0048
< 0.0005
< 0.0007
< 0.0006
< 0.0007
< 0.0009
< 0.0012
< 0.0025
< 0.0041 12-3 T-7 3rd Quarter 4th Quarter TAP-6354 TAP-7835 3697 3658
< 0.0005
< 0.0004
< 0.0004
< 0.0003 0.102 +/- 0.024 0.065 +/- 0.016
< 0.025
< 0.026
< 0.0039
< 0.0009
< 0.0022
< 0.0012
< 0.0015
< 0.0011
< 0.0124
< 0.0058
< 0.0017
< 0.0009
< 0.0013
< 0.0006
< 0.0021
< 0.0015
< 0.0059
< 0.0039 T-8 3rd Quarter 4th Quarter TAP-6355 TAP-7836 3662 3690
< 0.0006
< 0.0005
< 0.0004
< 0.0004 0.086 +/- 0.014 0.066 +/- 0.013
< 0.024
< 0.018
< 0.0007
< 0.0012
< 0.0010
< 0.0017
< 0.0005
< 0.0010
< 0.0074
< 0.0078
< 0.0009
< 0.0009
< 0.0006
< 0.0008
< 0.0010
< 0.0012
< 0.0056
< 0.0042
Table 12.
Airborne particulates, analyses for strontium-89. strontium-90 and gamma-emitting isotopes.
Location Quarter Lab Code Volume (m3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterly Composite Units: pCi/m3 1st Quarter TAP-1960 3596
< 0.0007
< 0.0005 2nd Quarter TAP-4059 3747
< 0.0008
< 0.0007 0.064 +/- 0.017 0.108 +/- 0.014
< 0.022
< 0.016
< 0.0005
< 0.0011
< 0.0015
< 0.0011
< 0.0010
< 0.0009
< 0.0062
< 0.0042
< 0.0008
< 0.0004
< 0.0006
< 0.0006
< 0.0015
< 0.0008
< 0.0035
< 0.0027 1st Quarter 2nd Quarter TAP-1961 TAP-4060 3601 3749
< 0.0006
< 0.0007 0.0005 +/- 0.0002
< 0.0005 0.065 +/- 0.018 0.092 +/- 0.017
< 0.025
< 0.025
< 0.0017
< 0.0009
< 0.0021
< 0.0009
< 0.0012
< 0.0011
< 0.0076
< 0.0087
< 0.0012
< 0.0007
< 0.0010
< 0.0007
< 0.0018
< 0.0020
< 0.0056
< 0.0045 12-4 T-9 (C 3rd Quarter 4th Quarter TAP-6356 TAP-7837 3595 3722
< 0.0006
< 0.0005
< 0.0005
< 0.0004 0.087 +/- 0.018 0.062 +/- 0.019
< 0.025
< 0.024
< 0.0009
< 0.0011
< 0.0009
< 0.0027
< 0.0009
< 0.0011
< 0.0080
< 0.0097
< 0.0009
< 0.0010
< 0.0005
< 0.0012
< 0.0015
< 0.0013
< 0.0047
< 0.0057 T-11 (C 3rd Quarter 4th Quarter TAP-6357 TAP-7838 3745 3648
< 0.0005
< 0.0005
< 0.0004
< 0.0003 0.087 +/- 0.017 0.076 +/- 0.016
< 0.023
< 0.022
< 0.0012
< 0.0011
< 0.0012
< 0.0021
< 0.0008
< 0.0011
< 0.0060
< 0.0079
< 0.0008
< 0.0011
< 0.0011
< 0.0008
< 0.0020
< 0.0018
< 0.0065
< 0.0038
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Location Quarter Lab Code Volume (m:;)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-1 06 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterly Composite Units: pCi/m3 1st Quarter TAP-1962 3686
< 0.0005
< 0.0004 T-12 (C) 2nd Quarter TAP-4061 3669
< 0.0008
< 0.0005 0.068 +/- 0.014 0.099 +/- 0.015
< 0.023
< 0.023
< 0.0010
< 0.0013
< 0.0006
< 0.0019
< 0.0012
< 0.0013
< 0.0047
< 0.0067
< 0.0007
< 0.0005
< 0.0009
< 0.0010
< 0.0017
< 0.0020
< 0.0030
< 0.0038 T-27 C 1st Quarter 2nd Quarter TAP-1963 TAP-4062 3622 3689
< 0.0005
< 0.0006
< 0.0004
< 0.0005 0.072 +/- 0.013 0.103 +/- 0.018
< 0.016
< 0.021
< 0.0010
< 0.0008
< 0.0015
< 0.0016
< 0.0012
< 0.0008
< 0.0074
< 0.0036
< 0.0007
< 0.0008
< 0.0006
< 0.0006
< 0.0013
< 0.0016
< 0.0041
< 0.0030 12-5 3rd Quarter 4th Quarter TAP-6358 TAP-7839 3716 3714
< 0.0004
< 0.0004
< 0.0003
< 0.0003 0.097 +/- 0.019 0.066 +/- 0.013
< 0.024
< 0.025
< 0.0017
< 0.0010
< 0.0022
< 0.0018
< 0.0009
< 0.0007
< 0.0118
< 0.0050
< 0.0010
< 0.0009
< 0.0011
< 0.0007
< 0.0013
< 0.0018
< 0.0031
< 0.0043 3rd Quarter 4th Quarter TAP-6359 TAP-7840 3657 3660
< 0.0005
< 0.0004
< 0.0003
< 0.0003 0.087 +/- 0.016 0.066 +/- 0.014
< 0.025
< 0.019
< 0.0011
< 0.0011
< 0.0019
< 0.0012
< 0.0012
< 0.0009
< 0.0088
< 0.0041
< 0.0010
< 0.0009
< 0.0005
< 0.0008
< 0.0022
< 0.0012
< 0.0057
< 0.0040
Table 13. Area monitors (TLD), Quarterly.
Units: mR/91 1st Otr. a 2nd Otr.
2 3rd Otr.
4th Otr.
Indicator T-1 11.4+/-0.5 12.1 +/- 1.2 10.2+/-1.2 11.1 +/-1.1 T-2 12.7+/-1.0 12.5 +/- 1.0 11.3 +/- 1.2 14.0 +/- 1.4 T-3 11.0 +/- 1.1 12.5 +/- 0.8 9.7+/-1.4 15.9 +/- 1.6 T-4 12.5 +/-0.6 12.3 +/- 0.8 12.0+/-1.2 13.4 +/- 1.2 T-5 14.1+/-1.2 14.1+/-0.7 13.4 +/- 1.5 16.7 +/- 1.4 T-6 9.3 +/- 0.8 10.3 +/- 0.7 7.7 +/- 1.2 12.9 +/- 0.9 T-7 15.5 +/-0.6 19.6 +/- 0.7 15.8 +/- 1.1 20.1 +/- 0.9 T-8 21.3 +/- 1.2 22.8 +/- 2.0 23.3 +/- 1.8 23.5 +/- 1.8 T-10 12.9+/-0.8 15.8 +/- 0.9 12.3+/-1.4 16.5 +/- 1.0 T-38 11.3 +/- 0.5 13.0 +/- 1.3 10.8+/-1.2 13.5 +/- 1.5 T-39 11.9 +/- 1.0 11.2 +/-0.7 11.6 +/- 1.7 11.3 +/- 0.9 T-40 13.7+/-0.6 13.9 +/- 0.8 14.2 +/- 1.8 15.0 +/- 1.0 T-41 10.3 +/- 0.6 12.1 +/- 0.8 9.6 +/- 1.2 12.5 +/- 0.9 T-42 11.1 +/-0.6 10.9 +/- 1.0 9.3 +/- 1 A 11.6 +/- 1.1 T-43 14.1 +/- 0.7 17.3+/-1.0 13.9 +/- 1.3 18.2+/-1.1 T-44 17.1 +/- 1.0 18.1+/-1.8 14.7 +/- 1.8 19.6 +/- 1.8 T-45 20.9 +/- 0.5 20.3 +/- 0.8 17.4 +/- 1A 21.9 +/-0.9 T-46 11.8+/-1.0 12.3 +/- 1.0 11.3 +/- 1.5 14.6 +/- 1.3 T-47 10.8 +/- 1.0 10.7 +/- 0.7 7.0 +/- 1.3 11A +/-0.9 T-48 10.6 +/- 0.5 11.5 +/- 0.8 11.8 +/- 1.1 11.5 +/- 0.9 T-49 9.1 +/- 0.7 10.2 +/- 1.1 7.6 +/- 1.2 11.2 +/- 1 A T-50 14.3 +/- 0.5 16.9 +/- 1.7 14.8 +/- 1.2 16.2+/-1.7 T-51 16.8 +/- 1.2 16.8 +/- 1.5 17.6+/-1.9 16.9 +/- 1.8 T-52 16A+/-1.1 22.8 +/- 0.9 17.5 +/- 1.8 21.7 +/- 0.9 T-53 16.9 +/- 0.5 20.1 +/- 2.2 18.2 +/- 1.1 21.5 +/- 0.9 T-54 16.9 +/- 0.6 19.7+/-1.0 18.0 +/- 1.3 17.1 +/- 1.2 T-55 12.7 +/- 1.3 15.5+/-1.3 11.0+/-1.7 14.7 +/- 1.4 T-60 9.9 +/- 0.7 10A+/-1.5 7.5 +/-0.9 12.1 +/- 1.7 T-62 11.3 +/-0.4 10.0 +/- 0.9 9.8 +/- 0.6 12.1 +/- 1.5 T-65 16.1 +/- 0.9 18.3+/-1.1 14.9 +/- 0.9 21.4+/-2.1 T-66 18.2 +/-0.7 18.6 +/- 1.9 17.7 +/- 0.8 21.0 +/- 2.2 T-67 20.5 +/- 0.5 17.2 +/-0.9 16.3 +/- 1.0 23.3 +/- 1.4 T-68 17.2 +/- 1.7 15.7 +/-0.9 15.0 +/- 1.3 16.9+/-1.1 T-69 15.2 +/- 0.8 15.0 +/-0.8 14.4 +/- 0.6 20.3 +/- 1.0 T-71 17.0 +/- 0.6 14.6 +/- 0.9 16.1+/-0.9 17.0+/-1.1 T-73 14.2 +/-1.2 14.0+/-1.1 10.6+/-1.1 15.7 +/- 1.2 T-74 15.2 +/- 0.9 15.6 +/- 1.6 14.0 +/- 1.6 17.0 +/-1.7 T-75 11.5 +/- 0.5 16.1 +/- 0.8 11.8 +/- 0.5 37.8 +/- 1.3 T-76 13.0 +/- 0.5 11.8 +/- 1.0 12.1 +/- 0.6 13.0 +/- 1.3 T-91 18.5 +/- 0.6 17.8+/-1.3 18.9 +/- 1.0 22.0 +/- 2.4 T-92 12.7 +/- 0.5 13.9 +/- 0.9 11.9 +/- 0.5 15.9 +/- 1.1 13-1
Table 13. Area monitors (TLD). Quarterly.
Units: mR/91 2nd Otr.
3rd Otr.
Indicator T-93 12.4 +/- 0.7 13.9 +/- 1.1 11.2 +/- 1.0 13.8 +/- 1.1 T-94 17.0 +/- 0.9 19.1 +/-1.4 13.6 +/- 1.0 18.6 +/- 1.2 T-112 12.4 +/- 0.5 12.3 +/- 1.1 10.5 +/- 0.6 15.4 +/- 1.5 T-121 19.0 +/- 1.6 22.7 +/- 1.3 17.7 +/- 1.3 22.0 +/- 1.4 T-122 14.6 +/- 1.0 16.5 +/-0.8 13.0 +/- 1.0 16.5 +/- 1.2 T-123 17.0 +/- 0.5 18.1 +/- 0.8 17.0 +/- 1.1 17.4 +/- 1.0 T-125 15.4 +/- 0.8 18.3 +/- 0.9 16.6 +/- 1.0 16.5 +/- 1.1 T-126 14.2 +/- 0.5 14.7+/-1.1 15.5 +/- 0.6 13.2 +/- 1.2 T-127 17.3 +/- 1.0 20.6 +/- 1.3 18.9 +/- 0.9 18.4 +/- 1.4 T-128 18.1 +/- 1.8 21.0 +/- 0.9 16.4 +/- 1.6 19.7 +/- 1.3 T-142 10.0 +/- 0.6 12.5+/-1.0 9.3 +/- 0.4 12.2 +/- 1.2 T-150 11.8 +/- 0.5 15.5+/-1.5 12.4 +/- 1.3 14.8 +/- 1.9 T-151 16.5 +/- 0.6 20.9 +/- 1.0 17.4+/-0.9 20.5 +/- 1.3 T-153 18.7 +/- 0.5 21.4 +/- 0.9 21.8+/-0.9 20.2 +/- 1.1 T-154 13.8 +/- 1.5 16.7 +/- 1.2 14.6 +/- 1.3 16.2 +/- 1.4 T-201 13.9 +/- 0.6 13.5 +/- 0.3 15.1+/-0.2 11.6 +/- 0.3 T-202 12.8 +/- 0.9 13.3 +/- 0.3 13.5 +/-0.7 14.2 +/- 0.8 T-203 13.8 +/- 0.8 15.1 +/- 1.0 13.2 +/-0.5 13.8 +/- 1.4 T-204 12.5 +/- 0.7 14.6 +/- 1.0 13.1 +/- 0.4 11.9 +/- 0.9 T-205 10.6 +/- 0.7 10.8 +/- 0.6 10.5 +/- 0.3 9.5 +/- 0.4 T-206 11.5 +/- 0.8 12.6 +/- 0.3 12.1 +/- 0.5 10.2 +/- 0.4 T-207 10.3 +/- 1.0 11.0 +/- 0.6 10.6 +/- 0.8 10.0 +/- 0.8 T-208 10.9+/-1.1 10.6 +/- 0.4 11.5 +/- 1.1 10.7 +/-0.5 T-211 13.2+/-1.2 10.9 +/- 0.6 13.5 +/- 1.4 9.0 +/- 0.9 T-212 9.8 +/- 0.6 11.3+/-0.7 8.9 +/- 0.6 10.1 +/- 1.2 T-213 16.9 +/- 0.6 19.1 +/- 0.8 18.1 +/- 0.7 16.8 +/- 1.2 T-214 18.6 +/- 0.6 18.0 +/- 0.7 16.3 +/- 0.5 15.1+/-1.0 T-215 17.6 +/- 0.7 21.1+/-0.7 17.4 +/- 0.7 16.6 +/- 1.4 T-216 15.9 +/-0.6 18.1 +/- 1.1 16.3 +/-0.7 16.9 +/- 1.2 T-217 19.3 +/- 0.8 23.2 +/- 1.8 20.7 +/- 0.9 18.0+/-1.4 T-218 19.7 +/- 0.9 25.2+/-1.0 21.8+/-1.1 20.2+/-1.3 T-219 15.4+/-1.0 18.0 +/- 1.1 13.5+/-1.1 15.8 +/- 1.5 T-220 19.9 +/- 0.5 22.2 +/- 1.4 20.5 +/- 0.6 19.0 +/- 1.9 T-222 12.9 +/- 0.7 15.2 +/-0.6 13.3 +/- 1.4 12.6 +/- 1.1 T-223 13.4 +/- 0.9 14.6 +/- 0.9 13.2 +/- 1.0 12.2 +/- 0.9 T-224 17.1 +/- 0.8 18.8 +/- 1.0 18.0 +/- 1.1 16.1 +/- 1.1 Mean+/- s.d.
14.4+/-3.1 15.8 +/- 3.8 14.0 +/- 3.6 16.0 +/- 4.4 13-2
Table 13. Area monitors (TLD}, Quarterly.
Units: mR/91 1st Otr.
2 2nd Otr.
2 3rd Otr.
Control T-9 13.1+/-0.8 14.0 +/- 1.0 13.2+/-1.2 15.1 +/-1.2 T-11 13.8 +/- 0.5 14.5 +/- 1.0 13.0 +/- 1.2 16.0 +/- 1.0 T-12 17.1 +/- 0.6 20.2 +/- 1.1 18.0+/-1.3 17.5 +/- 1.1 T-24 16.0 +/-0.7 18.8 +/- 0.8 17.4 +/- 2.0 19.3 +/- 1.0 T-27 16.4+/-0.8 20.1 +/-1.1 16.1 +/- 1.3 19.1 +/- 1.0 Mean+/- s.d.
15.3 +/- 1.7 17.5 +/- 3.0 15.5 +/- 2.3 17.4 +/- 1.9 T-95 15.8 +/- 1.0 17.4 +/- 0.9 12.1 +/- 1.2 16.5 +/- 1.2 T-100 16.3 +/- 1.1 18.1+/-1.2 15.6+/-1.2 17.2 +/- 1.5 T-111 17.0 +/- 1.3 20.1 +/- 1.0 15.1 +/- 1.7 18.7 +/- 1.5 T-124 17.8 +/- 1.0 20.5 +/- 1.0 20.6 +/- 1.0 20.2 +/- 1.2 T-155 14.5 +/- 0.8 15.7 +/- 1.7 14.6 +/- 0.9 16.0 +/- 1.5 T-221 17.9 +/- 1.2 20.5 +/- 0.9 19.7+/-1.3 18.2 +/- 1.5 Mean+/- s.d.
16.6+/-1.3 18.7 +/- 2.0 16.3 +/- 3.2 17.8 +/- 1.6 oc T-80 8.7 +/- 0.9 11.2 +/- 0.8 8.2 +/- 0.8 12.3+/-1.1 T-81 18.0 +/- 0.6 19.0 +/- 0.8 18.6 +/- 0.8 20.1+/-1.1 T-82 9.1 +/- 0.5 10.6 +/- 0.8 7.3 +/- 0.6 11.9+/-1.1 T-83 10.6 +/- 0.7 11.6+/-1.7 9.2 +/- 0.8 13.1 +/- 1.9 T-84 11.2 +/- 0.7 12.0 +/- 0.9 9.4 +/- 0.8 13.3 +/- 1.1 T-85 12.5 +/-0.6 11.7+/-1.0 10.7 +/- 0.7 12.7 +/- 1.1 T-86 18.5 +/- 0.9 20.5 +/- 1.4 18.8 +/- 1.2 23.1 +/- 1.7 T-88 16.0 +/- 1.0 16.9+/-1.0 12.6 +/- 1.1 17.7+/-1.5 T-89 14.4 +/- 0.8 19.0 +/- 0.8 13.8 +/- 1.1 18.6 +/- 1.1 T-113 12.7 +/-0.9 14.4 +/- 1.2 10.4 +/- 1.1 14.2 +/- 1.3 T-114 19.4 +/- 0.5 20.2 +/- 0.9 18.5 +/- 0.6 18.2 +/- 1.1 T-115 14.0 +/- 1.0 16.0 +/- 1.0 12.3 +/- 0.9 14.9 +/- 1.2 T-116 17.9 +/- 0.7 21.0 +/- 1.2 16.2 +/-0.7 19.4+/-1.3 T-117 14.7 +/- 1.0 13.4 +/- 1.2 13.0 +/-0.8 12.2+/-1.5 T-118 14.3 +/- 0.7 15.5 +/- 1.4 11.9+/-0.7 14.4+/-1.1 T-119 12.7 +/- 1.1 16.5 +/- 1.0 10.5 +/- 0.9 15.8 +/- 1.2 T-120 11.4+/-0.7 13.2 +/- 1.0 8.9 +/- 0.7 12.7 +/-1.2 T-200 12.5 +/- 0.6 14.2 +/-0.7 13.0+/-0.8 13.3 +/- 1.8 Mean+/- s.d.
13.8 +/- 3.2 15.4 +/-3.4 12.4 +/- 3.6 15.4 +/- 3.3 Shield T-87 5.4 +/- 0.5 7.0 +/- 1.0 3.0 +/- 0.5 7.2 +/- 1.2 a In-transit exposure was estimated.
13-3
Table 14. Area monitors (TLD), Annual.
Units: mR/365 days Indicator 2013 T-1 36.2 +/- 1.1 T-2 48.1 +/- 1.7 T-3 46.5 +/- 2.3 T-4 40.0 +/- 1.7 T-5 45.1 +/- 1.7 T-6 43.4+/-1.2 T-7 68.4 +/- 4.6 T-8 85.3 +/- 1.9 T-10 59.1 +/- 2.6 T-38 43.5 +/- 1.8 T-39 37.7 +/- 1.6 T-40 57.7 +/- 2.2 T-41 35.7 +/- 1.1 T-42 50.1 +/- 2.5 T-43 64.8 +/- 2.3 T-44 78.6 +/- 3.0 T-45 92.7 +/- 3.8 T-46 56.2 +/- 3.0 T-47 34.5 +/- 1.1 T-48 46.7 +/- 1.6 T-49 50.1 +/- 2.4 T-50 69.9 +/- 3.1 T-51 74.1 +/- 2.7 T-52 74.5 +/- 2.8 T-53 72.3 +/- 2.0 T-54 66.9 +/- 1.9 T-55 61.9 +/-5.2 T-60 44.0 +/- 2.2 T-62 40.0 +/- 2.3 T-65 60.4 +/- 4.4 T-66 72.4 +/- 2.7 T-67 72.6 +/- 2.5 T-68 57.1 +/- 2.3 T-69 65.3+/-2.1 T-71 62.5 +/- 1.5 T-73 44.9 +/- 1.2 T-74 51.1 +/- 2.1 T-75 74.6 +/- 5.1 T-76 41.0+/-1.9 T-91 67.5 +/- 1.2 T-92 45.7 +/- 1.7 14-1
Table 14. Area monitors (TLD), Annual.
Indicator T-93 T-94 T-112 T-121 T-122 T-123 T-125 T-126 T-127 T-128 T-142 T-150 T-151 T-153 T-154 T-201 T-202 T-203 T-204 T-205 T-206 T-207 T-208 T-211 T-212 T-213 T-214 T-215 T-216 T-217 T-218 T-219 T-220 T-222 T-223 T-224 Units: mR/365 days Mean+/- s.d.
aND= No Data, TLD lost in the field.
2013 46.8 +/- 1.5 61.9 +/- 1.9 47.1 +/- 1.4 72.8 +/- 2.8 57.6 +/- 1.7 63.2 +/- 1.6 66.6 +/- 1.8 52.9 +/- 0.8 69.2 +/- 2.5 67.7 +/- 5.8 36.5 +/- 1.6 49.8 +/- 4.3 66.7 +/- 1.1 69.2 +/- 2.6 53.7 +/- 1.5 56.3 +/- 2.8 54.5 +/- 3.1 58.1+/-2.8 50.1+/-3.1 46.1 +/- 2.9 44.9 +/- 3.6 41.5 +/- 2.8 43.3 +/- 2.8 34.8 +/- 3.2 40.3 +/- 2.3 68.4+/-3.1 64.6+/-2.1 74.3 +/- 2.7 59.8 +/- 3.8 72.1 +/- 5.8 86.7 +/- 2.6 55.9 +/- 2.9 74.6 +/- 2.8 48.0 +/- 1.9 49.0 +/- 3.1 57.2 +/- 3.7 57.2 +/- 13.6 14-2
Table 14. Area monitors (TLD), Annual.
T-9 T-11 T-12 T-24 T-27 Units: mR/365 da s Mean+/- s.d.
T-95 T-100 T-111 T-124 T-155 T-221 Mean+/- s.d.
T-80 T-81 T-82 T-83 T-84 T-85 T-86 T-88 T-89 T-113 T-114 T-115 T-116 T-117 T-118 T-119 T-120 T-200 Mean+/- s.d.
T-87 2013 60.3 +/- 1.4 45.1 +/- 1.4 56.0 +/- 2.0 69.1 +/- 2.4 65.1 +/- 1.8 59.1 +/- 9.3 56.7 +/- 3.0 66.2 +/- 2.3 59.5 +/- 3.5 62.8 +/- 2.9 53.0 +/- 2.1 67.8 +/- 2.1 61.0 +/- 5.7 38.4 +/- 1.1 70.9 +/- 1.8 36.8 +/- 0.9 33.5 +/- 1.6 42.3 +/- 1.4 44.7 +/- 2.7 70.7 +/- 4.3 58.7 +/- 1.6 66.6 +/- 4.3 56.1 +/- 2.4 68.2 +/- 2.2 50.7 +/- 1.8 62.4 +/- 1.4 52.0 +/- 1.0 56.2 +/- 1.5 48.7 +/- 2.8 39.6 +/- 1.3 49.1 +/- 3.3 52.5 +/- 12.0 17.9 +/- 1.7 14-3
Table 15. Milk, analyses for strontium-89, strontium-90, iodine-131, gamma emitting isotopes.
Monthly collections. location T-24 Units: pCi!L Date Collected 01-29-13 02-26-13 04-03-13 05-01-13 Lab Code TMI-373 TMI-777 TMI-1479 TMI-2233 1-131
<0.4
< 0.3
< 0.3
< 0.3 Sr-89
< 0.6
< 0.6
< 0.5
< 0.6 Sr-90
<0.4 0.8 +/- 0.3 0.6 +/- 0.3
< 0.5 K-40 1392 +/- 107 1492 +/- 143 1316 +/- 159 1356 +/- 114 Cs-134
< 3.4
< 4.3
< 4.9
< 2.5 Cs-137
< 4.1
< 5.5
< 6.0
< 4.0 Ba-La-140
< 6.0
< 6.0
< 11.5
< 4.2 Ca (g/L) 1.10 1.17 1.52 1.12 Sr-90/g Ca
< 0.36 0.68 0.39
< 0.45 K (g/L) 1.70 +/- 0.13 1.82 +/- 0.17 1.60 +/- 0.19 1.65 +/- 0.14 Cs-137/g K
< 2.41
< 3.02
< 3.75
< 2.42 Date Collected 06-05-13 07-02-13 07-31-13 08-28-13 Lab Code TMI-2952 TMI-3626 TMI-4411 TMI-5077 1-131
< 0.3
< 0.3
< 0.3
< 0.2 Sr-89
< 0.5
< 0.6
< 0.6
< 0.6 Sr-90
< 0.6
< 0.5 0.7 +/- 0.3
< 0.6 K-40 1421 +/- 93 1534 +/- 130 1420 +/- 108 1485 +/- 127 Cs-134
< 2.8
< 4.9
< 1.9
< 3.1 Cs-137
< 2.7
< 3.0
< 4.0
< 3.9 Ba-La-140
< 4.5
< 4.3
< 1.9
< 3.1 Ca (g/L) 1.10 1.01 1.00 1.10 Sr-90/g Ca
< 0.55
< 0.50 0.70
< 0.55 K (g/L) 1.73 +/- 0.11 1.87+/-0.16 1.73+/-0.13 1.81 +/- 0.15 Cs-137/g K
< 1.56
< 1.60
< 2.31
< 2.15 Date Collected 09-25-13 10-30-13 12-04-13 12-31-13 Lab Code TMI-5647 TMI-6692 TMI-7298 TMI-7644 1-131
< 0.3
< 0.2
< 0.5
< 0.2 Sr-89
< 0.6
< 0.6
< 0.5
< 0.6 Sr-90 0.7 +/- 0.4
< 0.5
< 0.5 0.6 +/- 0.3 K-40 1346 +/- 138 1338 +/- 115 1296 +/- 109 1313 +/- 100 Cs-134
< 4.3
< 4.0
< 3.9
< 3.8 Cs-137
< 5.7
< 3.7
<1.4
< 3.7 Ba-La-140
< 4.4
< 2.2
< 1.2
< 1.9 Ca (g/L) 1.08 1.23 1.03 1.04 Sr-90/g Ca 0.65
< 0.41
< 0.49 0.58 K (g/L) 1.64+/-0.17 1.63 +/- 0.14 1.58 +/- 0.13 1.60 +/- 0.12 Cs-137/g K
< 3.48
< 2.27
< 0.89
< 2.31 15-1
Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Units: pCi/L Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Location T-27A{C}
Lab Code ND TWW-2997 TWW-4487 TWW-6755 Req. LLD Date Collected 05-08-13 07-16-13 10-10-13 Gross beta 2.1 +/- 1.2 2.5 +/- 0.7 1.0 +/- 0.3 4.0 H-3
< 330
< 330
< 330 330 Sr-89
< 1.0
< 0.9
< 0.8 Sr-90
<0.4
< 0.6
< 0.5 Mn-54
< 2.7
< 2.6
< 1.3 15 Fe-59
< 7.6
< 3.6
< 3.6 30 Co-58
< 2.3
< 1.6
< 1.2 15 Co-60
< 1.8
< 1.6
< 1.2 15 Zn-65
< 4.2
< 2.7
< 2.2 30 Zr-Nb-95
< 5.2
< 2.2
< 2.6 15 Cs-134
< 2.1
< 2.2
< 1.1 15 Cs-137
< 2.2
< 2.0
<1.4 18 Ba-La-140
< 14.0
< 4.2
< 3.9 15 Location T-225 (I}
Lab Code ND TWW-2999 TWW-4489 TWW-6757 Req. LLD Date Collected 05-22-13 07-17-13 10-10-13 Gross beta 2.0 +/- 0.6 1.9 +/- 0.3 1.4 +/- 0.4 4.0 H-3
< 330
< 330
< 330 330 Sr-89
< 1.0
< 0.9
< 0.8 Sr-90
< 0.5
< 0.6
< 0.5 Mn-54
< 2.6
< 1.9
< 1.8 15 Fe-59
< 4.6
< 3.9
< 4.4 30 Co-58
< 3.8
< 2.5
< 2.5 15 Co-60
< 2.3
< 2.3
< 1.9 15 Zn-65
<2.4
< 3.1
< 3.9 30 Zr-Nb-95
< 5.0
< 5.1
< 2.6 15 Cs-134
< 2.7
< 2.2
< 2.0 15 Cs-137
< 2.5
< 3.0
< 1.9 18 Ba-La-140
< 8.4
< 6.7
< 4.7 15 ND = No Data, Sample not received.
16-1
Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Units: pCi/L Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Location T-226 ~Q Lab Code NO TWW-3000 TWW-4490 TWW-6758 Req. LLD Date Collected 05-08-13 07-17-13 10-10-13 Gross beta 1.8 +/- 0.8 1.2 +/- 0.3 1.3 +/- 0.4 4.0 H-3
< 330
< 330
< 330 330 Sr-89
< 1.4
< 0.8
< 0.8 Sr-90
< 0.6
< 0.5
<0.4 Mn-54
< 2.1
<1.4
< 1.9 15 Fe-59
< 6.0
< 4.6
< 3.8 30 Co-58
< 3.6
< 2.2
< 1.5 15 Co-60
< 1.5
< 1.5
< 1.8 15 Zn-65
< 2.1
< 2.2
< 2.1 30 Zr-Nb-95
< 3.8
< 4.2
< 1.9 15 Cs-134
< 1.9
< 3.5
< 1.9 15 Cs-137
< 2.7
< 2.2
< 2.2 18 Ba-La-140
< 8.4
< 3.9
< 8.0 15 Location T-141 {QC}
Lab Code NO TWW-2998 TWW-4488 TWW-6756 Req. LLD Date Collected 05-08-13 07-17-13 10-10-13 Gross beta 1.0 +/- 0.6 2.1 +/- 0.3 4.4 +/- 1.5 4.0 H-3
< 330
< 330
< 330 330 Sr-89
< 1.1
< 1.3
< 0.9 Sr-90
< 0.5
< 0.8
< 0.5 Mn-54
< 2.7
< 2.0
< 1.9 15 Fe-59
< 5.0
< 4.7
< 3.8 30 Co-58
< 2.1
< 2.0
< 1.1 15 Co-60
< 2.4
<1.4
< 2.4 15 Zn-65
< 3.3
< 5.0
< 2.2 30 Zr-Nb-95
< 5.5
< 2.6
< 3.4 15 Cs-134
< 2.5
< 1.8
< 2.0 15 Cs-137
< 2.6
< 3.2
< 1.7 18 Ba-La-140
< 10.8
< 4.5
< 8.4 15 NO= No Data, Sample not received.
16-2
Table 19. Green leafy vegetables, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.
Collection: Monthly, in season Units: pCi/g wet Location T-227 (I)
Lab Code TVE-5093 TVE-5653 Date Collected 08-28-13 09-25-13 Sample Type Cabbage Cabbage Sr-89
< 0.006
< 0.005 Sr-90
< 0.003
< 0.003 1-131
< 0.012
< 0.019 K-40 3.67 +/- 0.27 5.38 +/- 0.35 Nb-95
< 0.006
< 0.011 Zr-95
< 0.007
< 0.019 Cs-134
< 0.006
< 0.010 Cs-137
< 0.009
< 0.010 Ce-141
< 0.011
< 0.024 Ce-144
< 0.055
< 0.052 Location T-19 (I)
Lab Code TVE-4520 TVE-5092 TVE-5649 TVE-6709 Date Collected 08-06-13 08-28-13 09-25-13 10-29-13 Sample Type Cabbage Cabbage Cabbage Cabbage Sr-89
< 0.004
< 0.003
< 0.005
< 0.003 Sr-90
< 0.002
< 0.003
< 0.004
< 0.002 1-131
< 0.006
< 0.011
< 0.012
< 0.016 K-40 2.20 +/- 0.16 2.49 +/- 0.23 1.85 +/- 0.19 2.18 +/- 0.18 Nb-95
< 0.006
< 0.007
< 0.007
< 0.007 Zr-95
< 0.009
< 0.013
< 0.013
< 0.009 Cs-134
< 0.004
< 0.005
< 0.005
< 0.007 Cs-137
< 0.005
< 0.008
< 0.004
< 0.007 Ce-141
< 0.011
< 0.016
< 0.008
< 0.015 Ce-144
< 0.039
< 0.069
< 0.045
< 0.056 Location T-37 (C)
Lab Code TVE-4412 TVE-5651 Date Collected 07-31-13 09-25-13 Sample Type Cabbage Cabbage Sr-89
< 0.003
< 0.003 Sr-90
< 0.002
< 0.002 1-131
< 0.018
< 0.010 K-40 2.05 +/- 0.20 2.59 +/- 0.22 Nb-95
< 0.006
< 0.008 Zr-95
< 0.011
< 0.012 Cs-134
< 0.007
< 0.006 Cs-137
< 0.006
< 0.006 Ce-141
< 0.013
< 0.019 Ce-144
< 0.067
< 0.063 19-1
Table 20. Fruit, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.
Collection: Monthly, in season Units: pCi/g wet Location T -8 (I)
T-25 (I)
Lab Code TVE-5648 TVE-5650 Date Collected 09-25-13 09-25-13 Sample Type Apples Apples Sr-89
< 0.001
< 0.002 Sr-90
< 0.001
< 0.001 1-131
< 0.016
< 0.011 K-40 1.08 +/- 0.17 1.18+/-0.14 Nb-95
< 0.007
< 0.005 Zr-95
< 0.014
< 0.006 Cs-134
< 0.005
< 0.005 Cs-137
< 0.006
< 0.006 Ce-141
< 0.013
< 0.010 Ce-144
< 0.058
< 0.048 Location T-209 (C)
Lab Code TVE-5652 Date Collected 09-25-13 Sample Type Apples Sr-89
< 0.002 Sr-90
< 0.001 1-131
< 0.009 K-40 1.01 +/- 0.13 Nb-95
< 0.004 Zr-95
< 0.007 Cs-134
< 0.004 Cs-137
< 0.005 Ce-141
< 0.009 Ce-144
< 0.047 20-1
Table 22. Soil samples, analyses for gamma-emitting isotopes.
Collection: Annual Units: pCi/g dry Location T-1 T-2 T-3 T-4 Lab Code TSO-2269 TSO-2270 TSO-2271 TSO-2272 Date Collected 05-01-13 05-01-13 05-01-13 05-01-13 Be-7 0.37 +/- 0.19 1.21 +/- 0.35 0.71 +/- 0.26 0.88 +/- 0.31 K-40 11.82 +/- 0.66 4.43 +/- 0.50 8.29 +/- 0.63 8.35 +/- 0.69 Mn-54
< 0.019
< 0.024
< 0.027
< 0.027 Nb-95
< 0.020
< 0.026
< 0.031
< 0.023 Zr-95
< 0.033
< 0.032
< 0.025
< 0.029 Ru-103
< 0.016
< 0.016
< 0.018
< 0.026 Ru-106
< 0.125
< 0.120
< 0.136
< 0.117 Cs-134
< 0.016
< 0.019
< 0.015
< 0.017 Cs-137
< 0.016 0.24 +/- 0.024 0.038 +/- 0.021
< 0.015 Ce-141
< 0.054
< 0.053
< 0.049
< 0.061 Ce-144
< 0.098
< 0.071
< 0.122
< 0.110 Location T-7 T-8 Lab Code TSO-2273 TSO-2274 Date Collected 05-01-13 05-01-13 Be-7
< 0.32 0.50 +/- 0.25 K-40 20.01 +/- 0.94 21.53 +/- 0.99 Mn-54
< 0.035
< 0.034 Nb-95
< 0.024
< 0.043 Zr-95
< 0.032
< 0.038 Ru-103
< 0.033
< 0.024 Ru-106
< 0.089
< 0.174 Cs-134
< 0.018
< 0.026 Cs-137
< 0.029 0.12 +/- 0.042 Ce-141
< 0.078
< 0.080 Ce-144
< 0.131
< 0.136 Location T-9 T-11 T-12 T-27 Lab Code TSO-2275 TSO-2276 TSO-2277 TSO-2278 Date Collected 05-01-13 05-01-13 05-01-13 05-01-13 Be-7
< 0.30
< 0.27
< 0.23
< 0.28 K-40 23.16 +/- 0.98 16.11 +/- 0.82 14.90 +/- 0.83 19.99 +/- 0.99 Mn-54
< 0.036
< 0.030
< 0.027
< 0.036 Nb-95
< 0.035
< 0.039
< 0.032
< 0.039 Zr-95
< 0.039
< 0.064
< 0.029
< 0.054 Ru-103
< 0.033
< 0.028
< 0.030
< 0.033 Ru-106
< 0.257
< 0.117
< 0.205
< 0.145 Cs-134
< 0.024
< 0.017
< 0.022
< 0.023 Cs-137 0.12 +/- 0.044 0.11 +/- 0.034 0.083 +/- 0.033 0.15 +/- 0.035 Ce-141
< 0.076
< 0.060
< 0.071
< 0.063 Ce-144
< 0.191
< 0.175
< 0.142
< 0.156 22-1
Table 23. Treated surface water samples, analyses for gross beta.
Collection: Monthly composites of weekly grab samples Units: pCi/L T-11 (C)
Lab Code Date Collected Gross Beta Lab Code TSWT-361 01-29-13 0.9 +/- 0.4 TSWT-363 TSWT-783 02-26-13
< 1.8 TSWT-784 TSWT-1532 04-02-13 1.1 +/- 0.4 TSWT-1533 TSWT-2297 04-30-13 0.8 +/- 0.4 TSWT-2298 TSWT-2985 06-04-13 1.8 +/- 0.6 TSWT-2986 TSWT-3646 07-02-13 0.9 +/- 0.5 TSWT-3647 TSWT-4470 07-30-13 1.4 +/- 0.4 TSWT-4471 TSWT-5244 09-03-13 1.2 +/- 0.6 TSWT-5245 TSWT-5819 10-01-13 2.1 +/- 0.8 TSWT-5820 TSWT-6751 10-29-13 2.6 +/- 0.5 TSWT-6752 TSWT-7319 12-03-13
< 0.8 TSWT-7320 TSWT-7659 12-30-13 1.9 +/- 1.0 TSWT-7660 T-22 TSWT-364 01-29-13 0.9 +/- 0.4 TSWT-365 TSWT-785 02-26-13 2.5 +/- 1.0 TSWT-786 TSWT-1534 04-02-13 1.2 +/- 0.4 TSWT-1535 TSWT-2299 04-30-13 1.1 +/- 0.4 TSWT-2300 TSWT-2988 06-04-13 2.0 +/- 1.0 TSWT-2989 TSWT-3648 07-02-13 1.1 +/- 0.5 TSWT-3649 TSWT-4472 07-30-13 1.6 +/- 0.4 TSWT-4473 TSWT-5246 09-03-13 1.6 +/- 0.6 TSWT-5247 TSWT-5821 10-01-13 2.1 +/- 0.8 TSWT-5822 TSWT-6753 10-29-13 1.8 +/- 0.5 TSWT-6754 TSWT-7321 12-03-13 1.5 +/- 0.6 TSWT-7322 TSWT-7661 12-30-13
< 1.8 TSWT-7662 23-1 T-12 (C)
Date Collected Gross Beta 01-29-13
< 0.6 02-26-13 2.2 +/- 0.9 04-02-13 1.2 +/- 0.4 04-30-13 0.7 +/- 0.4 06-04-13 1.0 +/- 0.5 07-02-13
< 0.8 07-30-13 1.0 +/- 0.4 09-03-13 1.2 +/- 0.5 10-01-13 1.9 +/- 0.7 10-29-13 1.7 +/- 0.4 12-03-13
< 0.8 12-30-13 3.1 +/- 1.0 T-143 (QC) 01-29-13 2.0 +/- 0.5 02-26-13 2.8 +/- 1.0 04-02-13 1.2 +/- 0.4 04-30-13 0.8 +/- 0.4 06-04-13 2.3 +/- 1.0 07-02-13 1.2 +/- 0.5 07-30-13 1.9+/- 0.4 09-03-13
< 0.9 10-01-13 2.1 +/- 0.7 10-29-13 1.6 +/- 0.5 12-03-13 1.1 +/- 0.5 12-30-13 2.3 +/- 1.0
Table 24.
Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly composites of weekly grab samples Units: pCi/L T-11 (C) 1st Otr.
2nd Otr.
3rd Otr.
TSWT-1584 TSWT-3758 TSWT-5993
< 330
< 330
< 330
< 0.9
< 0.9
< 0.7
< 0.5
< 0.7
< 0.5
< 3.8
< 2.9
< 3.3
< 7.4
< 3.3
< 7.9
< 2.6
<1.7
< 4.9
< 2.8
< 2.2
< 3.6
< 5.9
< 5.3
< 4.3
< 4.0
< 2.7
< 3.5
< 2.6
< 2.7
< 2.8
< 4.0
< 3.6
< 4.5
< 5.9
< 5.8
< 7.0 T-12 c 1st Otr.
2nd Otr.
3rd Otr.
TSWT-1585 TSWT-3759 TSWT-5994
< 330
< 330
< 330
< 0.8
< 1.0
< 0.7
< 0.5
< 0.6
< 0.5
< 3.5
< 1.5
< 3.5
< 8.6
< 3.6
< 5.9
< 4.5
< 2.2
< 3.2
< 2.6
< 1.5
< 3.6
< 6.6
< 6.8
< 6.5
< 2.6
< 3.1
< 3.0
< 3.5
< 2.2
< 3.3
< 4.5
< 1.6
< 3.8
< 7.7
< 2.0
< 4.1 24-1 4th Otr.
TSWT-7671
< 330
< 0.6
< 0.5
< 3.0
< 5.8
< 2.9
< 2.8
< 6.2
< 5.4
< 4.1
< 5.5
< 5.7 4th Otr.
TSWT-7672
< 330
< 0.7
< 0.6
< 2.9
< 4.1
< 1.9
< 1.7
< 6.3
< 2.2
< 3.1
< 2.7
< 5.2 Reg. LLD 330 15 30 15 15 30 15 10 18 15 Reg. LLD 330 15 30 15 15 30 15 10 18 15
Table 24.
Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly composites of weekly grab samples.
Units: pCi/L T-22 1st Qtr.
2nd Qtr.
3rd Qtr.
TSWT-1586 TSWT-3760 TSWT-5995
< 330
< 330
< 330
< 1.0
< 0.8
< 0.7
<0.4
< 0.5
< 0.5
< 3.8
< 1.3
< 2.2
< 3.3
< 2.1
< 5.6
< 3.5
<1.4
< 3.1
< 3.3
< 2.1
< 3.2
< 6.3
< 3.2
< 3.8
< 2.5
< 3.2
< 4.0
< 2.8
< 2.1
< 3.8
< 3.2
< 3.1
< 3.5
< 8.0
< 2.8
< 3.8 24-2 4th Qtr.
TSWT-7673
< 330
< 0.6
< 0.5
< 2.2
< 5.5
< 1.8
< 1.4
< 4.8
< 3.3
< 2.8
< 3.4
< 3.2 Reg. LLD 330 15 30 15 15 30 15 10 18 15
Table 25. Untreated surface water. analyses for gross beta. tritium and gamma emitting isotopes.
Location T -3 Collection* Monthly composites of weekly grab samples Units Lab Code TSWU-366 TSWU-787 TSWU-1536 TSWU-2301 Date Collected 01-29-13 02-26-13 04-02-13 04-30-13 Req. LLD Gross beta 4.9 +/- 0.6 4.9 +/- 1.2 4.8 +/- 0.9 3.1 +/- 0.5 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 2.9
< 1.8
< 4.2
< 1.9 15 Fe-59
< 3.1
< 3.2
< 5.0
< 3.0 30 Co-58
< 3.2
< 2.9
< 3.5
< 1.8 15 Co-60
< 2.4
< 2.6
< 3.3
< 1.7 15 Zn-65
< 6.1
< 4.8
< 3.3
< 2.7 30 Zr-Nb-95
< 2.8
< 2.5
< 2.9
< 3.0 15 Cs-134
< 2.7
< 2.7
< 3.1
< 3.4 10 Cs-137
< 2.9
< 3.0
< 4.0
< 3.2 18 Ba-La-140
< 1.8
< 2.4
< 4.5
< 4.3 15 Lab Code TSWU-2990 TSWU-3651 TSWU-4474 TSWU-5248 Date Collected 06-04-13 07-02-13 07-30-13 09-03-13 Req. LLD Gross Beta 2.4 +/- 0.7 3.4 +/- 1.1 3.7 +/- 0.5 3.7+/- 1.0 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 3.5
< 1.7
< 2.2
< 2.7 15 Fe-59
< 4.1
< 3.5
< 4.8
< 5.2 30 Co-58
< 2.2
< 3.2
< 1.5
< 1.9 15 Co-60
< 1.9
< 3.5
< 1.8
< 2.0 15 Zn-65
< 4.0
< 1.8
< 4.0
< 3.8 30 Zr-Nb-95
< 4.1
< 2.4
< 3.1
< 2.8 15 Cs-134
< 2.7
< 2.4
< 2.5
< 2.1 10 Cs-137
< 2.5
< 1.6
< 2.4
< 3.2 18 Ba-La-140
< 5.5
< 3.1
< 2.1
< 2.2 15 Lab Code TSWU-5838 TSWU-6759 TSWU-7323 TSWU-7663 Date Collected 10-01-13 10-29-13 12-03-13 12-30-13 Req. LLD Gross Beta 2.1 +/- 0.5 3.1 +/- 0.7 2.9 +/- 0.8 2.9 +/- 0.7 4.0 H-3
< 330
< 330 352 +/- 88
< 330 330 Mn-54
< 4.4
< 3.3
< 2.0
< 3.3 15 Fe-59
< 8.4
< 4.0
< 3.8
< 5.8 30 Co-58
< 4.6
< 2.0
< 1.2
< 2.8 15 Co-60
< 3.3
< 2.2
< 2.4
< 3.1 15 Zn-65
< 6.2
< 5.3
< 6.6
< 7.7 30 Zr-Nb-95
< 5.7
< 3.5
< 4.0
< 4.6 15 Cs-134
< 4.0
< 3.2
< 3.4
< 3.7 10 Cs-137
< 3.7
< 3.5
< 3.5
< 3.9 18 Ba-La-140
< 4.9
< 4.0
< 1.5
< 2.6 15 a Activity verified by reanalysis, 390 +/- 97 pCi!L.
25-1
Table 25. Untreated surface water. analyses for gross beta. tritium and gamma emitting isotopes.
Location T-11 (C)
Collection Monthly composites of samples Units Lab Code TSWU-368 TSWU-789 TSWU-1539 TSWU-2303 Date Collected 01-29-13 02-26-13 04-02-13 04-30-13 Req. LLD Gross beta 1.2 +/- 0.4 4.0 +/- 1.1 2.2 +/- 0.7 1.9 +/- 0.4 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 2.5
< 2.1
< 2.9
< 2.3 15 Fe-59
< 4.2
< 4.1
< 4.1
< 4.2 30 Co-58
< 3.0
< 2.3
< 3.5
< 3.4 15 Co-60
< 3.0
< 2.0
< 3.0
< 2.4 15 Zn-65
< 5.5
< 2.7
< 9.7
< 4.7 30 Zr-Nb-95
< 2.1
< 2.7
< 6.3
< 3.9 15 Cs-134
< 3.9
< 2.5
< 3.6
< 2.2 10 Cs-137
< 2.2
< 2.5
< 4.7
< 3.7 18 Ba-La-140
< 3.9
< 2.5
< 5.5
< 2.1 15 Lab Code TSWU-2992 TSWU-3653 TSWU-4476 TSWU-5250 Date Collected 06-04-13 07-02-13 07-30-13 09-03-13 Req. LLD Gross Beta
< 1.8 1.5+/-0.4 2.3 +/- 0.5 1.6 +/- 0.6 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 1.5
< 2.2
< 2.8
< 2.7 15 Fe-59
< 4.7
< 2.4
< 4.9
< 5.3 30 Co-58
< 4.0
< 3.3
< 2.7
< 3.0 15 Co-60
< 2.4
< 2.1
< 2.2
< 1.3 15 Zn-65
< 3.1
< 5.3
< 4.6
< 4.8 30 Zr-Nb-95
< 2.7
< 3.5
< 2.7
< 1.9 15 Cs-134
< '2.9
< 3.1
< 2.2
< 2.9 10 Cs-137
< 3.7
< 3.2
< 3.4
< 2.7 18 Ba-La-140
< 6.7
< 3.9
< 2.3
< 2.3 15 Lab Code TSWU-5840 TSWU-6761 TSWU-7325 TSWU-7666 Date Collected 10-01-13 10-29-13 12-03-13 12-30-13 Req. LLD Gross Beta 1.2 +/- 0.4 2.2 +/- 0.6 2.5 +/- 0.8 1.0 +/- 0.5 4.0 H-3 340 +/- 105
< 330
< 330
< 330 330 Mn-54
< 3.0
< 3.7
< 2.9
< 2.1 15 Fe-59
< 6.7
< 4.9
< 5.4
< 3.4 30 Co-58
< 3.0
< 3.3
< 1.4
< 3.4 15 Co-60
< 4.0
< 4.1
< 2.9
< 2.8 15 Zn-65
< 3.1
< 7.5
< 2.1
< 3.4 30 Zr-Nb-95
< 4.2
< 5.5
< 1.8
< 4.1 15 Cs-134
< 2.6
< 4.3
< 2.5
< 3.6 10 Cs-137
< 4.0
< 4.4
< 2.5
< 2.6 18 Ba-La-140
< 5.5
< 4.5
< 2.9
< 2.6 15 25-2
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location T-12 (C)
Collection Monthly composites of weekly grab samples Units Lab Code TSWU-369 TSWU-790 TSWU-1540 TSWU-2304 Date Collected 01-29-13 02-26-13 04-02-13 04-30-13 Req. LLD Gross beta 1.8 +/- 0.5 2.7 +/- 1.0 2.2 +/- 0.8 1.3 +/- 0.4 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 3.2
< 2.6
< 2.7
< 2.5 15 Fe-59
< 4.4
< 3.9
< 4.7
< 5.0 30 Co-58
< 2.1
< 2.8
< 3.0
< 2.5 15 Co-60
< 3.6
< 3.1
< 2.5
< 3.0 15 Zn-65
< 5.8
< 2.6
< 2.9
< 2.7 30 Zr-Nb-95
< 2.5
< 3.2
< 3.2
< 2.7 15 Cs-134
< 3.2
< 3.0
< 2.6
< 2.3 10 Cs-137
< 4.2
< 2.5
< 3.3
< 2.5 18 Ba-La-140
< 4.5
< 2.4
< 2.6
< 2.5 15 Lab Code TSWU-2993 TSWU-3654 TSWU-4477 TSWU-5252 Date Collected 06-04-13 07-02-13 07-30-13 09-03-13 Req. LLD Gross Beta 1.7 +/- 0.9 1.7+/-0.5 1.9 +/- 0.4 1.4+/-0.6 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 2.1
< 2.7
< 4.4
< 1.9 15 Fe-59
< 4.5
< 3.9
< 8.1
< 9.1 30 Co-58
< 1.8
< 1.9
< 3.3
< 5.2 15 Co-60
< 2.2
< 1.6
< 2.5
< 2.8 15 Zn-65
< 4.0
< 2.4
< 7.1
< 8.8 30 Zr-Nb-95
< 3.5
< 2.3
< 6.2
< 3.7 15 Cs-134
< 1.9
< 2.3
< 4.6
< 2.3 10 Cs-137
< 2.5
< 3.3
< 5.3
< 4.7 18 Ba-La-140
< 3.8
< 1.1
< 4.5
< 6.7 15 Lab Code TSWU-5841 TSWU-6762 TSWU-7326 TSWU-7667 Date Collected 10-01-13 10-29-13 12-03-13 12-30-13 Req. LLD Gross Beta 1.3 +/- 0.4 1.4 +/- 0.5 2.2 +/- 0.7 1.3 +/- 0.6 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 4.3
< 3.4
< 1.8
< 2.8 15 Fe-59
< 6.4
< 5.7
< 3.0
< 2.9 30 Co-58
< 3.3
< 1.6
< 2.2
< 2.6 15 Co-60
< 4.9
< 1.9
< 2.0
< 1.8 15 Zn-65
< 5.9
< 3.5
< 3.1
< 5.1 30 Zr-Nb-95
< 4.4
< 2.9
< 2.9
< 2.4 15 Cs-134
< 4.1
< 3.2
< 2.9
< 2.8 10 Cs-137
< 3.8
< 2.5
< 3.3
< 2.2 18 Ba-La-140
< 3.6
< 6.0
< 2.0
< 2.1 15 25-3
Table 25. Untreated surface water. analyses for gross beta. tritium and gamma emitting isotopes.
Location T-22 Collection Monthly composites of grab samples Units pCi/L Lab Code TSWU-371 TSWU-793 TSWU-1542 TSWU-2306 Date Collected 01-29-13 02-26-13 04-02-13 04-30-13 Req. LLD Gross beta 2.3 +/- 0.5 1.6 +/- 0.6 2.5 +/- 0.4 1.9 +/- 0.5 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 2.6
< 2.8
< 2.1
< 1.7 15 Fe-59
< 8.1
< 5.6
< 3.1
< 4.7 30 Co-58
< 2.4
< 2.0
< 2.3
< 2.4 15 Co-60
< 3.6
< 2.2
< 3.4
< 2.1 15 Zn-65
< 4.4
< 3.0
< 3.0
< 5.3 30 Zr-Nb-95
< 2.7
< 2.2
< 3.0
< 2.8 15 Cs-134
< 4.2
< 1.8
< 3.4
< 2.3 10 Cs-137
< 3.5
< 2.8
< 2.0
< 3.4 18 Ba-La-140
< 5.3
< 1.8
< 4.1
< 4.1 15 Lab Code TSWU-2995 TSWU-3656 TSWU-4480 TSWU-5254 Date Collected 06-04-13 07-02-13 07-30-13 09-03-13 Req. LLD Gross Beta
< 0.9 1.2 +/- OA 1.5 +/- OA 1.9 +/- 0.6 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 1.6
< 3.0
< 2.0
< 2.6 15 Fe-59
< 6.3
< 2.1
< 4.7
< 4.2 30 Co-58
< 2.6
< 1.8
< 1.4
< 3.7 15 Co-60
< 2.3
< 2.1
< 1.8
< 1.8 15 Zn-65
< 2.2
< 1.8
< 2.0
< 4.2 30 Zr-Nb-95
< 4.5
< 2.6
< 3.1
< 3.8 15 Cs-134
< 2.0
< 3.1
< 1.8
< 3.3 10 Cs-137
< 2.4
< 2.8
< 2.8
< 2.3 18 Ba-La-140
< 2.3
< 2.2
< 3.2
< 5.5 15 Lab Code TSWU-5843 TSWU-6764 TSWU-7328 TSWU-7669 Date Collected 10-01-13 10-29-13 12-03-13 12-30-13 Req. LLD Gross Beta 1.1 +/- OA 1.1 +/- 0.6 2.7 +/- 0.8 2.5 +/- 0.8 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 2.7
< 2.5
< 3.1
< 2.3 15 Fe-59
< 5.6
< 3.7
< 3.7
< 1.8 30 Co-58
< 3.7
< 2.1
< 2.8
< 2.7 15 Co-60
< 4.1
< 1.4
< 2.3
< 1.4 15 Zn-65
< 4.8
< 1.5
< 3.6
< 5.2 30 Zr-Nb-95
< 3.7
< 2.9
< 3.1
< 2.4 15 Cs-134
< 2.8
< 3.0
< 2.6
< 2.6 10 Cs-137
< 4.3
< 2.8
< 3.3
< 3.4 18 Ba-La-140
< 3.9
< 2.1
< 1.2
< 3.0 15 25-4
Table 25. Untreated surface water, analyses for gross beta. tritium and gamma emitting isotopes.
Location T-145 (QC)
Collection Monthly composites of grab samples Units Lab Code TSWU-372 TSWU-794 TSWU-1543 TSWU-2307 Date Collected 01-29-13 02-26-13 04-02-13 04-30-13 Req. LLD Gross beta 1.1 +/- 0.4 2.0 +/- 0.6 2.5 +/- 0.4 1.5 +/- 0.4 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 2.5
< 4.0
< 3.9
< 2.0 15 Fe-59
< 6.1
< 6.7
< 4.9
< 3.9 30 Co-58
< 2.5
< 3.2
< 3.2
< 2.2 15 Co-60
< 3.5
< 3.1
< 4.6
< 2.2 15 Zn-65
< 4.2
< 6.9
< 4.9
< 3.1 30 Zr-Nb-95
< 3.4
< 2.2
< 2.7
< 2.5 15 Cs-134
< 3.2
< 3.3
< 3.1
< 2.7 10 Cs-137
< 4.9
< 3.8
< 3.9
< 2.1 18 Ba-La-140
< 4.7
< 6.3
< 4.7
< 3.7 15 Lab Code TSWU-2996 TSWU-3657 TSWU-4481 TSWU-5255 Date Collected 06-04-13 07-02-13 07-30-13 09-03-13 Req. LLD Gross Beta 1.4 +/- 0.5 1.2+/-0.4 1.6 +/- 0.5 1.6 +/- 0.6 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 4.2
< 2.3
< 2.7
< 2.1 15 Fe-59
< 6.0
< 4.3
< 4.8
< 3.6 30 Co-58
< 3.8
< 2.5
< 3.9
< 2.5 15 Co-60
< 2.5
< 3.2
< 2.8
< 3.5 15 Zn-65
< 6.6
< 5.8
< 3.1
< 3.9 30 Zr-Nb-95
< 4.6
< 3.0
< 2.6
< 3.6 15 Cs-134
< 2.8
< 2.9
< 3.3
< 2.4 10 Cs-137
< 4.5
< 2.3
< 3.7
< 3.1 18 Ba-La-140
< 8.7
< 4.1
< 4.6
< 3.3 15 Lab Code TSWU-5844 TSWU-6765 TSWU-7329 TSWU-7670 Date Collected 10-01-13 10-29-13 12-03-13 12-30-13 Req. LLD Gross Beta 2.5 +/- 0.8 3.1 +/- 0.6 1.8 +/- 1.0 3.1 +/- 0.8 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 3.0
< 1.8
< 3.2
< 4.0 15 Fe-59
< 4.4
< 2.9
< 4.5
< 4.0 30 Co-58
< 4.1
< 1.5
< 2.3
< 3.3 15 Co-60
< 3.7
< 1.7
< 2.5
< 4.6 15 Zn-65
< 3.8
< 3.5
< 3.6
< 7.3 30 Zr-Nb-95
< 2.4
< 3.2
< 3.1
< 5.8 15 Cs-134
< 3.5
< 2.7
< 3.2
< 5.6 10 Cs-137
< 3.2
< 2.4
< 2.9
< 5.3 18 Ba-La-140
< 5.4
< 3.3
< 1.3
< 3.8 15 25-5
Table 26. Untreated surface water samples, analyses for strontium-89 and strontium-90.
Collection: Quarterly composites of weekly grab samples Units: pCi/L T-3 Period 1st Otr.
2nd Otr.
3rd Otr.
4th Otr.
Lab Code TSWU-1816 TSWU-3753 TSWU-6092 TSWU-7702 Sr-89
< 1.0
< 0.8
< 0.7
< 0.6 Sr-90
< 1.0
< 0.5
< 0.5
< 0.5 Location T-11 c Period 1st Qtr.
2nd Otr.
3rd Otr.
4th Qtr.
Lab Code TSWU-1817 TSWU-3754 TSWU-6093 TSWU-7703 Sr-89
< 0.8
< 1.0
< 0.8
< 0.7 Sr-90
< 0.5
< 0.6
< 0.5
< 0.6 Location T-12 C Period 1st Otr.
2nd Qtr.
3rd Otr.
4th Otr.
Lab Code TSWU-1818 TSWU-3755 TSWU-6094 TSWU-7704 Sr-89
< 0.7
< 0.8
< 0.8
< 0.6 Sr-90
<0.4
< 0.5
< 0.6
< 0.5 Location T-22 Period 1st Qtr.
2nd Qtr.
3rd Otr.
4th Otr.
Lab Code TSWU-1819 TSWU-3757 TSWU-6096 TSWU-7705 Sr-89
< 0.7
< 0.9
< 1.0
< 0.6 Sr-90
<0.4
< 0.6
< 0.7
< 0.5 26-1
Table 27. Fish samples, analyses for gross beta and gamma-emitting isotopes.
Collection Annually Units: pCi/g wet Location Lab Code TF-3404 Date Collected 05-31-13 Sample Type Walleye Gross Beta 3.93 +/- 0.11 K-40 3.50 +/- 0.47 Mn-54
< 0.019 Fe-59
< 0.094 Co-58
< 0.029 Co-60
< 0.013 Zn-65
< 0.019 Cs-134
< 0.014 Cs-137
< 0.024 Location Lab Code TF-3406 Date Collected 05-20-13 Sample Type Carp Gross Beta 4.10 +/- 0.12 K-40 2.86 +/- 0.37 Mn-54
< 0.008 Fe-59
< 0.067 Co-58
< 0.018 Co-60
< 0.016 Zn-65
< 0.029 Cs-134
< 0.015 Cs-137
< 0.015 T-33 (Lake Erie, 1.5 mi. NE of Station)
TF-3405 05-31-13 Bass I Perch 3.97 +/- 0.12 4.03 +/- 0.48
< 0.015
< 0.055
< 0.028
< 0.013
< 0.030
< 0.017
< 0.014 T-35 TF-3408 TF-3409 05-18-13 03-13-13 Bass I Perch Walleye 3.61 +/- 0.10 4.33+/-0.12 2.89 +/- 0.35 3.26 +/- 0.34
< 0.011
< 0.012
< 0.029
< 0.139
< 0.018
< 0.026
< 0.012
< 0.009
< 0.036
< 0.038
< 0.013
< 0.011
< 0.016
< 0.013 27-1
Table 28. Shoreline sediment samples, analyses for gamma-emitting isotopes.
Collection: Semiannually Units: pCi/g dry Location T-3 Lab Code TSS-2745 Date Collected 05-22-13 K-40 9.25 +/- 0.51 Mn-54
< 0.019 Co-58
< 0.014 Co-60
< 0.014 Cs-134
< 0.011 Cs-137
< 0.013 Lab Code TSS-7332 Date Collected 11-20-13 K-40 9.52 +/- 0.49 Mn-54
< 0.009 Co-58
< 0.011 Co-60
< 0.006 Cs-134
< 0.012 Cs-137
< 0.010 T-4 TSS-2746 05-22-13 12.80 +/- 0.71
< 0.024
< 0.031
< 0.015
< 0.018
< 0.020 TSS-7333 11-20-13 11.79 +/- 0.63
< 0.011
< 0.020
< 0.015
< 0.011
< 0.014 T-4P T-27B TSS-2747 TSS-2748 05-22-13 05-21-13 12.93 +/- 0.89 9.96 +/- 0.53
< 0.037
< 0.017
< 0.048
< 0.013
< 0.021
< 0.011
< 0.031
< 0.012
< 0.034
< 0.018 TSS-7334 TSS-7336 11-20-13 11-26-13 15.51 +/- 0.72 9.56 +/- 0.49
< 0.021
< 0.016
< 0.031
< 0.015
< 0.021
< 0.008
< 0.021
< 0.011
< 0.027
< 0.013 28-1 T-132 TSS-2749 05-21-13 7.50 +/- 0.46
< 0.018
< 0.020
< 0.012
< 0.010
< 0.009 TSS-7337 11-26-13 9.41 +/- 0.48
< 0.016
< 0.014
< 0.005
< 0.013
< 0.005
APPENDIX B DATA REPORTING CONVENTIONS B-1
Data Reporting Conventions 1.0. All activities, except gross alpha and gross beta, are decay corrected to collection time or the end of the collection period.
2.0. Single Measurements Each single measurement is reported as follows:
x +/- s where:
x = value of the measurement; s = 2cr counting uncertainty (corresponding to the 95% confidence level).
In cases where the activity is less than the lower limit of detection L, it is reported as: < L, where L =the lower limit of detection based on 4.66cr uncertainty for a background sample.
3.0. Duplicate analyses If duplicate analyses are reported, the convention is as follows. :
3.1 Individual results: For two analysis results; x1 +/- s1 and x2 +/- s2 Reported result:
x +/- s; where x = (1/2) (x1 + x2) and s = (1/2) ~
s 1 2 + s; 3.2.
Individual results:
< L1, < L2 Reported result: < L, where L = lower of L1 and L2 3.3.
Individual results:
x +/- s, < L Reported result:
x +/- s if x ::: L; < L otherwise.
4.0. Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for exaf::!ple, an annual standard deviation would not be the average of quarterly standard deviations. The average x and standard deviation "s" of a set of n numbers x1, x2... xn are defined as follows:
X = n 2: X
--~
s-
\\j~
4.2 Values below the highest lower limit of detection are not included in the average.
4.3 If all values in the averaging group are less than the highest LLD, the highest LLD is reported.
4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error is reported.
4.5 In rounding off, the following rules are followed:
4.5.1.
If the number following those to be retained is less than 5, the number is dropped, and the retained numbers are kept unchanged. As an example, 11.443 is rounded off to 11.44.
4.5.2.
If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 11.45.
B-2