MONTHYEARML1002903652010-01-27027 January 2010 University of California, Irvine - Reactor Response to NRC Request for Additional Information Dated December 3, 2009 Re License Renewal Request Project stage: Response to RAI ML1014000272010-05-17017 May 2010 University of California, Irvine, Response to the Request for Additional Information Dated December 3, 2009 in Regard to License Renewal Request Project stage: Request ML1013902512010-05-26026 May 2010 University of California at Irvine, Request for Additional Information, Regarding License Renewal for the University of California Irvine Nuclear Reactor Facility Project stage: RAI ML0932404982010-06-18018 June 2010 FRN: General Notice. University of California, Irvine Notice of Acceptance for Docketing of Application and Opportunity for Hearing Regarding the Renewal of Facility Operating License Project stage: Acceptance Review ML1013302772010-06-29029 June 2010 University of California, Irvine - Letter to Licensee Regarding Federal Register Notice of Acceptance for Docketing of Application and Opportunity for Hearing Project stage: Acceptance Review ML1019700392010-07-14014 July 2010 University of California, Irvine - Response to Request for Additional Information Dated May 25, 2010 Regarding License Renewal Request Project stage: Response to RAI ML1104002022011-01-26026 January 2011 Univ of California, Irvine Nuclear Reactor Facility RAI Re License Renewal, May 26, 2010 Project stage: Other ML1108805212011-04-0505 April 2011 University of California at Irvine - Request for Additional Information Regarding the License Renewal for the University of California Irvine Nuclear Reactor Facility Project stage: RAI ML11130A0272011-04-28028 April 2011 University of California, Irvine, Request Additional Time to Respond to Request for Additional Information for the Review of Proposed Technical Specifications Project stage: Request ML1115201912011-06-0202 June 2011 University of California at Irvine - Response to University of California at Irvine Letter - Request for Additional Time to Response to Staff Additional Information for the License Renewal Project stage: Other ML1119503792011-06-0707 June 2011 University of California, Irvine - *Redacted* Licensee Response to NRC Request for Additional Information Dated May 26, 2010 and Transmittal Letter of Thermal-Hydraulic Analysis and Nuclear Analysis for Uci Triga Reactor Project stage: Response to RAI ML11188A0832011-06-24024 June 2011 Response to Relicense, Request for Additional Information Dated 04/05/2011 Project stage: Request ML1119503802011-07-0707 July 2011 University of California, Irvine - *Redacted* Thermal-Hydraulic Analysis for Uci Triga Reactor Project stage: Request ML11255A0732011-08-0101 August 2011 University of California - Irvine Response to Request for Additional Information Dated April 5, 2011 (TAC ME1579), Additional Response Material - Extension Granted to August 1st, 2011 Project stage: Response to RAI ML1201100122011-10-0303 October 2011 University of California, Irvine - *Redacted* Revised MHA Analysis, ALARA Program Policy Statement and Proposed Technical Specifications Project stage: Other ML11290A0412011-10-0505 October 2011 University of California, Irvine Nuclear Reactor Facility, Update to Facility Organization Project stage: Request ML1135300102011-12-0202 December 2011 University of California, Irvine - Licensee Response to NRC Request for Additional Information License Renewal Maximum Hypothetical Accident, (Redacted Version) Project stage: Response to RAI ML11348A1042011-12-0202 December 2011 University of California, Irvine, Docket 50-326 Relicense Project stage: Request NRC-2010-0217, FRN: General Notice, University of California at Irvine - Environmental Assessment and Finding of No Significant Impact2012-02-0202 February 2012 FRN: General Notice, University of California at Irvine - Environmental Assessment and Finding of No Significant Impact Project stage: Other ML1102504102012-02-0202 February 2012 University of California at Irvine - Letter to Licensee, Environmental Assessment Regarding the Renewal of Facility License No. R-116 for the University of California at Irvine Nuclear Reactor Project stage: Other ML1102600652012-02-0202 February 2012 FRN: General Notice, University of California at Irvine - Environmental Assessment and Finding of No Significant Impact Project stage: Other ML13099A0782013-04-15015 April 2013 FRN: General Notice: University of California, Irvine - Supplement to Environmental Assessment (77 Fr 7610-7613) Waste Confidence Rule (Tac No. ME1579) Project stage: Other ML13113A0022013-05-0606 May 2013 University of California, Irvine - Letter to Licensee Supplement to Federal Register for Environmental Assessment Waste Confidence Rule Project stage: Other ML13144A5812013-05-23023 May 2013 University of California, Irvine - Submittal of Emergency Plan Changes Incorporated Under 10 CFR 50.54(q) Project stage: Request ML14024A6822014-01-30030 January 2014 University of California, Irvine - Request for Additional Information Review of the Emergency Plan for License Renewal for the University of California, Irvine Nuclear Reactor Facility Project stage: RAI ML14073A0732014-02-26026 February 2014 University of California, Irvine, Response to NRCs RAI Regarding the Reactor Emergency Plan, Dated January 30, 2014 Project stage: Other ML14065A4452014-03-0505 March 2014 Letter from George E. Miller to Mr. Lising Docket 50-326 R-116 Project stage: Request ML14121A5172014-05-0808 May 2014 University of California, Irvine - Request for Additional Information Financial Update for License Renewal for the University of California, Irvine Nuclear Reactor Facility (Tac No. Me1579) Project stage: RAI ML14121A5212014-05-28028 May 2014 University of California, Irvine - Transmittal Letter for Request for Additional Information Review of the Physical Security Plan for License Renewal for the University of California, Irvine Nuclear Reactor Facility Project stage: RAI ML14135A5032014-07-15015 July 2014 University of California, Irvine Request for Additional Information License Renewal for the University of California, Irvine Nuclear Reactor Facility Project stage: RAI ML16027A1262015-12-22022 December 2015 University of California, Irvine - Response to Technical Request for Additional Information (Dated July 15, 2014) Project stage: Request ML16125A4872016-04-22022 April 2016 Univ. of California-Irvine - Proposed Technical Specifications Project stage: Request ML16125A1492016-04-29029 April 2016 University of California, Irvine Request That License Limits for Triga Mark I Nuclear Reactor Facility Be Established Project stage: Request ML16141A1152016-05-13013 May 2016 University of California Irvine - Letter Dated 05/13/2016 Requesting Revision to Proposed Technical Specifications Project stage: Request ML1203100202016-07-0707 July 2016 University of California Irvine - Technical Specifications Issued with Renewed Facility Operating License No. R-116 (Tac No. ME1579) Project stage: Other ML1203100162016-07-0808 July 2016 University of California Irvine - Letter to Licensee Issuing Renewed Facility Operating License No. R-116 (Tac No. ME1579) Project stage: Other ML1203100072016-07-0808 July 2016 FRN: General Notice - University of California Irvine - Notice of Issuance of Renewed Facility Operating License No. R-116 (Tac No. ME1579) Project stage: Approval ML1203100222016-07-0808 July 2016 University of California Irvine - Safety Evaluation Supporting Renewed Facility Operating License No. R-116 (Tac No. ME1579) Project stage: Approval 2011-08-01
[Table View] |
Text
OFFICIAL USE ONLY - SECURITY RELATED INFORMATION OFFICIAL USE ONLY - SECURITY RELATED INFORMATION May 28, 2014 Dr. George E. Miller Department of Chemistry University of California, Irvine 326 Rowland Hall Irvine, CA 92697-2025
SUBJECT:
UNIVERSITY OF CALIFORNIA, IRVINE - REQUEST FOR ADDITIONAL INFORMATION RE: REVIEW OF THE PHYSICAL SECURITY PLAN FOR THE LICENSE RENEWAL FOR THE UNIVERSITY OF CALIFORNIA, IRVINE NUCLEAR REACTOR FACILITY (TAC NO. ME1579)
Dear Dr. Miller:
The U.S. Nuclear Regulatory Commission (NRC) is continuing its review of the University of California, Irvine (UCI) application for the renewal of Facility Operating License No. R-116 for the UCI Nuclear Reactor Facility, dated October 18, 1999 (a redacted version of the application is available on the NRCs public Web site at www.nrc.gov under Agencywide Documents Access and Management System (ADAMS) Accession No. ML083110112), as supplemented.
The NRC staff review of your license renewal application includes a review of your current physical security plan, titled Physical Security Plan, Nuclear Reactor Facility, University of California, Irvine, Revision 4, dated February 2014, submitted by letter dated March 5, 2014 (ADAMS Accession No. ML14065A445). Our review identified 14 questions, which are provided in the enclosed request for additional information (RAI). Please provide your response to the enclosed RAI within 30 days from the date of this letter.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) Section 50.30(b), you must execute your response in a signed original document under oath or affirmation. Your response must be submitted in accordance with 10 CFR 50.4, Written communications.
Information included in your response that is considered sensitive or proprietary, that you seek to have withheld from the public, must be marked in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Any information related to security should be submitted in accordance with 10 CFR 73.21, Protection of Safeguards Information:
Performance requirements. Following receipt of the additional information, we will continue our evaluation of your license renewal request.
NOTE: Enclosure Transmitted Herewith Contains Security-Related Information. When Separated from the Enclosure this Document Is DECONTROLLED.
OFFICIAL USE ONLY - SECURITY RELATED INFORMATION OFFICIAL USE ONLY - SECURITY RELATED INFORMATION If you have any questions about this review or if you need additional time to respond to this request, please contact me by telephone at 301-415-3841 or by electronic mail at Jason.Lising@nrc.gov.
Sincerely,
/RA/
A. Jason Lising, Project Manager Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-326 License No. R-116
Enclosure:
RAI cc w/out encl.: See next page
University of California at Irvine Docket No. 50-326 cc:
Dr. Howard Gillman Executive Vice Chancellor and Provost 539 Aldrich Hall University of California, Irvine Irvine, CA 92697-2025 Dr. Reginald M. Penner, Chair Department of Chemistry University of California, Irvine Irvine, CA 92697-2025 Radiological Health Branch State Department of Health Services P.O. Box 997414, MS 7610 Sacramento, CA 95899-7414 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
ML14121A521 NRR-106 OFFICE DPR/PRLB/PM DPR/PRLB/LA DPR/PROB DPR/PROB/BC DPR/PRLB/BC DPR/PRLB/PM NAME JLising PBlechman EReed GBowman AAdams JLising DATE 05/15/2014 05/15/2014 05/19/2014 05/19/2014 05/22/2014 05/28/2014