v'ý,Entergy Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093 Tel 504 739 6685 Fax 504 739 6698 jjarrel@entergy.com John P. Jarrell III Manager - Regulatory Assurance Waterford 3 W3F1-2014-0030 April 28, 2014 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001
Subject:
Annual Radiological Environmental Operating Report -2013 Waterford Steam Electric Station, Unit 3 (Waterford 3)
Docket No. 50-382 License No. NPF-38
Dear Sir or Madam:
Attached is the Annual Radiological Environmental Operating Report for the period of January 1 through December 31, 2013. This report is submitted pursuant to the requirements of Waterford 3 Technical Specification Section 6.9.1.7.
This report contains no new commitments. Please contact John P. Jarrell, Regulatory Assurance Manager, at (504) 739-6685 if you have questions regarding this information.
=cerely,
Attachment:
Annual Radiological Environmental Operating Report-2013
-jE2-5 kilI~
W3F17-2014-0030 Page 2 cc:
Mr. Marc L. Dapas Regional Administrator U. S. Nuclear Regulatory Commission Region IV RidsRgn4MailCenter@nrc.gov NRC Senior Resident Inspector Waterford Steam Electric Station Unit 3 Marlone.Davis@nrc.gov Chris.Speer@nrc.gov NRC/NRR Project Manager for Waterford 3 Michael.Orenak@nrc.gov Alan.Wang@nrc.gov Allyson Howie Entergy Legal, General Sr Councel AHowie@entergy.com
Attachment to W3F1-2013-0030 Annual Radiological Environmental Operating Report - 2013 (63 pages)
mF~qF~
wEn tergy I
January 1, 2013-December 31, 2013 I
Annual Radiological I=nvirnmgml nr rafinr PI rA 2013 Wngirfhrd 3 5Rtagm Ep4ctrii tnqt~i~n K!&
U Ux Originator:
Ann V. Dubois, Chemistry Technician Date Reviewed By:
Date Chemistry Supervisor lucýý 6&'U'Z4ý Approved By:
41141h Date Nicole K. Lawless, Chemistry Manager
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station TABLE OF CONTENTS
SUMMARY
I
1.0 INTRODUCTION
5 1.1 Radiological Environmental Monitoring Program 5
1.2 Pathways Monitored 5
1.3 Land Use Census 5
2.0 INTERPRETATION AND TRENDS OF RESULTS 20 2.1 Air Particulate and Radioiodine Sample Results 20 2.2 Thermoluminescent Dosimetry Sample Results 20 2.3 Water Sample Results 21 2.4 Sediment Sample Results 21 2.5 Milk Sample Results 22 2.6 Fish Sample Results 22 2.7 Broad Leaf Vegetation Sample Results 22 2.8 Land Use Census Results 22 2.9 Interlaboratory Comparison Results 22 3.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
25 3.1 2013 Program Results Summary 25
- i -
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station I
U I
TABLE 1.1 TABLE 2.1 TABLE 3.1 LIST OF TABLES RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM BIENNIAL LAND USE CENSUS RESULTS RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
SUMMARY
6 23 26
- ii -
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station LIST OF FIGURES FIGURE 1-1 FIGURE 1-2 FIGURE 1-3 FIGURE 2-1 REMP SAMPLES WITHIN 2 MILES OF WATERFORD 3 REMP SAMPLES WITHIN 10 MILES OF WATERFORD 3 REMP SAMPLES WITHIN 50 MILES OF WATERFORD 3 TLD RADIATION DOSE COMPARISON (BY YEAR) 17 18 19 24
- iii -
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station LIST OF ATTACHMENTS ATTACHMENT I ATTACHMENT 2 2013 RADIOLOGICAL MONITORING REPORT
SUMMARY
OF MONITORING RESULTS STATISTICAL COMPARISONS 30 48
- iv -
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station Summary The Annual Radiological Environmental Operating Report presents data obtained through analyses of environmental samples collected for Waterford 3's (W3) Radiological Environmental Monitoring Program (REMP) for the period January 1 through December 31, 2013. This report fulfills the requirements of W3 Technical Specification 6.9.1.7.
During 2013, gross beta radioactivity was detected in air and drinking/surface water locations. Results obtained at the indicator locations were similar to those obtained at the control location. Therefore, levels continue to remain at background.
Radiological Environmental Monitoring Program W3 established the REMP prior to the station becoming operational (1985) to provide data on background radiation and radioactivity normally present in the area. W3 has continued to monitor the environment by sampling air, water, sediment, milk, fish and broad leaf vegetation, as well as measuring radiation directly.
The REMP includes sampling indicator and control locations within a 31-mile radius of the plant. The REMP utilizes indicator locations near the site to show any increases or buildup of radioactivity that might occur due to station operation, and control locations farther away from the site to indicate the presence of only naturally occurring radioactivity. W3 compares indicator results with control, preoperational, and previous years operational results to assess any impact W3 might have on the surrounding environment.
In 2013, W3 collected environmental samples for radiological analysis. Based on the comparison results of indicator locations with control locations and previous studies, it was concluded that overall W3 operations had no significant impact on plant environs. The review of 2013 data, in many cases, showed undetectable radiation levels in the environment and near background levels in significant pathways associated with W3.
Harmful Effects or Irreversible Damage The REMP did not detect any harmful effects or evidence of irreversible damage in 2013. Therefore, no analysis or planned course of action to alleviate problems was necessary.
1
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station Reporting Levels W3's review indicates that no samples equaled or exceeded reporting levels for radioactivity concentration in environmental samples, as outlined in Technical Requirements Manual (TRM)
Table 3.12-2 when averaged over any calendar quarter, due to W3 effluents. Therefore, 2013 results did not trigger any radiological monitoring program special reports.
Radioactivity Not Attributable to W3 The W3 REMP detected radioactivity attributable to other sources three times. These include the 25th Chinese nuclear test explosion in 1980, the radioactivity plume release due to reactor core degradation at the Chernobyl Nuclear Power Plant in 1986, and the airborne release from Dai-ichi, Fukushima following the Tohoku earthquake on March 11, 2011.
Comparison to State Program W3 compared REMP data to the monitoring program of the Environmental Radiological Laboratory -
Department of Environmental Quality Laboratory Services Division (ERL-DEQLSD). The ERL-DEQLSD and the W3 REMP entail similar radiological environmental monitoring program requirements. Both programs have obtained similar results over previous years.
Sample Deviations Milk Samples Since milk samples for indicator location MKE-3 were unavailable for all quarters of 2013, broad leaf vegetation sampling was performed as required by TRM Table 3.12-1. Broad leaf vegetation results are in section 2.7. Milk samples were collected from one control location and analyzed for Iodine-131 and gamma radionuclides. Results indicate that all measurements were below the calculated LLDs.
Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2013.
+ Air Samples The air sample locations listed below failed to meet the requirement for sample continuity. As described in footnote (1) of TRM Table 3.12-1, deviations are permitted from the required sampling schedule due to malfunction of sampling equipment and other legitimate reasons.
Location Sample Period Explanation of Deviation APF-1 08/05/13 - 08/19/13 Sample pump trip APQ-1 04/15/13 - 04/29/13 Loss of electrical power 2
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station Missed Samples One TLD located at station N-1 was missing at the time of the first quarter exchange. The phosphors in TLDs located at station A-5 were found to be wet at the time of the exchange. The TLDs, although placed in a desiccator, were found to be damaged. Results from those TLDs are considered suspect and not used in any calculations. TLDs located at stations D-2 and H-8 were missing at the time of the second quarter exchange. TLDs located at station H-8 were missing at the time of the third quarter exchange. TLDs located at stations A-5, D-5, and N-1 were missing at the time of the fourth quarter exchange.
Required Lower Limit of Detection (LLD) Values All LLDs during this reporting period were within the acceptable limits required by the W3 TRM.
Unavailable Results W3 received analytical results in adequate time for inclusion in this report. In addition, W3's review identified no missing results.
Program Modifications No program modifications were made during 2013.
3
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station Attachments contains results of air, TLD, water, sediment, milk, fish and broad leaf vegetation collected in 2013. TLDs were analyzed by Stanford Dosimetry. All remaining samples were analyzed by Teledyne Brown Engineering, Inc. Attachment 1 also contains Teledyne's participation in the interlaboratory comparison program during 2013. contains statistical comparisons of:
TLD measurements from stations grouped by distance TLD radiation dose to historical data by location Gross beta activity measurements on air particulate filters Gross beta activity measurements in surface/drinking water samples 4
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station 1.0 Introduction 1.1 Radiological Environmental Monitoring Program W3 established the REMP to ensure that plant operating controls properly function to minimize any associated radiation endangerment to human health or the environment. The REMP is designed for:
Analyzing important pathways for anticipated types and quantities of radionuclides released into the environment.
Considering the possibility of a buildup of long-lived radionuclides in the environment and identifying physical and biological accumulations that may contribute to human exposures.
Considering the potential radiation exposure to plant and animal life in the environment surrounding W3.
Correlating levels of radiation and radioactivity in the environment with radioactive releases from station operation.
1.2 Pathways Monitored The airborne, direct radiation, waterborne and ingestion pathways are monitored as required by W3 TRM Table 3.12-1. A description of the W3 REMP utilized to monitor the exposure pathways is described in Table 1.1 and shown in Figures 1-1, 1-2 and 1-3.
Section 2.0 of this report provides a discussion of 2013 sampling results with Section 3.0 providing a summary of results for the monitored exposure pathways.
1.3 Land Use Census W3 conducts a land use census biennially, as required by Section 3.12.2 of the TRM. The purpose of this census is to identify changes in uses of land within five miles of W3 that would require modifications to the REMP and the Offsite Dose Calculation Manual (ODCM). The most important criteria during this census are to determine the location in each sector of the nearest:
- 1) Residence
- 2) Animal milked for human consumption 2
2
- 3) Garden of greater than 50 m (500 ft ) producing broad leaf vegetation.
W3 conducts the land use census by:
Field surveys in each meteorological sector out to five miles in order to confirm:
- " Nearest permanent residence Nearest garden and approximate size Nearest beef cow Nearest food product Nearest milking animal Identifying locations on maps, measuring distances to W3 and recording results on data sheets.
Comparing current census results to previous results.
5
Annual Radiological Environmental Ooeratina Reoort 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Airborne Radioiodine and Particulates Three samples from close to the three APQ-1 (NW, 0.81 Miles) - (West bank)
Continuous sampler operation Radioiodine Canister 131 SITE BOUNDARY locations, in different Located in soybean/sugarcane field off with sample collection bi-analysis bi-weekly.
sectors, in or near sectors having the LA 18 east of LA 18/3141 intersection.
highest calculated annual average weekly, or more frequently if ground level D/Q.
APF-1 (ESE, 0.35 Miles) - (West bank) required by dust loading.
Particulate Sampler-Gross Located on north side of Secondary beta radioactivity analysis Meteorological Tower.
following filter change. Gamma APC-1 (NE, 0.67 Miles) - (East bank) isotopic analysis of composite Located inside Little Gypsy Cooling Water (by location) quarterly.
Intake Structure fence.
Radioiodine and Particulates One sample from the vicinity of a APP-1 (WNW, 0.84 Miles) - (West bank) community having the highest Located in soybean/sugarcane field on calculated annual average ground level Short St. in Killona.
D/Q.
Radioiodine and Particulates One sample from a control location, as APE-30 (E, 25.2 Miles) - (West bank) for example 15 -30 km distant and in Located on roof of Entergy Office building the least prevalent wind direction.
on Delaronde St. in Algiers. (Control) 6
Annual Radiological Environmental ODeratina Report 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An inner ring of stations, one in each A-2 (N, 1.27 Miles) - (East bank) Located Quarterly Gamma dose quarterly.
meteorological sector in the general on pole on LA 628 at Zephrin L. Perriloux area of the SITE BOUNDARY.
Fire House.
B-1 (NNE, 0.75 Miles) - (East bank)
Located on fence west of Little Gypsy.
C-1 (NE, 0.67 Miles) - (East bank) Located on fence at Little Gypsy Cooling Water Intake structure.
D-2 (ENE, 1.24 Miles) - (East bank)
Located on pole on levee at west entrance to Bonnet Carre Spillway.
7
Annual Radiological Environmental Operatinq Report 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An inner ring of stations, one in each E-1 (E, 0.41 Miles) - (West bank) Located on Quarterly Gamma dose quarterly.
meteorological sector in the general pole on LA 18 east of Waterford 3 plant area of the SITE BOUNDARY.
entrance.
F-2 (ESE, 1.15 Miles) - (West bank) Located on fence on LA 3142 south of LA 18.
G-2 (SE, 1.26 Miles) - (West bank) Located on fence on LA 3142 north of railroad overpass.
H-2 (SSE, 1.54 Miles) - (West bank) Located on fence on LA 3142 north of LA 3127/3142 intersection.
8
Annual Radiological Environmental Operatinq Report 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An inner ring of stations, one in each J-2 (S, 1.38 Miles) - (West bank) Located on Quarterly Gamma dose quarterly.
meteorological sector in the general fence south of LA 3127 west of LA 3127/3142 area of the SITE BOUNDARY.
intersection.
K-1 (SSW, 1.06 Miles) - (West bank) Located on stop sign at entrance to Entergy Education Center on LA 3127.
L-1 (SW, 1.06 Miles) - (West bank) Located on gate on LA 3127 west of LA 3127/3142 intersection.
M-1 (WSW, 0.76 Miles) -
(West bank)
Located on south gate of Waterford 1 and 2.
N-1 (W, 0.98 Miles) - (West bank) Located on pole at comer of Railroad Avenue and School House Road.
9
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An inner ring of stations, one in each P-1 (WNW, 0.84 Miles) - (West bank) Located Quarterly Gamma dose quarterly.
meteorological sector in the general on fence enclosing air sample station APP-I.
area of the SITE BOUNDARY.
Q-1 (NW, 0.81 Miles) - (West bank) Located on fence enclosing air sample station APQ-1.
R-1 (NNW, 0.51 Miles) - (West bank) Located at Waterford 1 and 2 Cooling Water Intake Structure.
TLDs An outer ring of stations, 1 in 10 of the A-5 (N, 4.59 Miles) - (East bank) Located on meteorological sectors in the 6 to 8 km pole at intersection of Oswald Avenue and US ranges from the site.
61.
10
Annual Radiological Environmental Operatina Reoort 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An outer ring of stations, 1 in 10 of the B-4 (NNE, 3.75 Miles) - (East bank) Located Quarterly Gamma dose quarterly.
meteorological sectors in the 6 to 8 km on pole near weigh station on US 61.
ranges from the site.
D-5 (ENE, 4.09 Miles) - (East bank) Located on gate on shell road north of US61/LA48 intersection.
F-4 (ESE, 3.53 Miles) - (West bank) Located on pole behind house at 646 Aquarius St. in Hahnville.
11
Annual Radiological Environmental Operatinq Report 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An outer ring of stations, 1 in 10 of the E-5 (E, 4.08 Miles) - (East bank) Located on Quarterly Gamma dose quarterly.
meteorological sectors in the 6 to 8 km fence on Wesco Street off LA 48.
ranges from the site.
G-4 (SE, 3.30 Miles) - (West bank) Located on pole on LA 3160 north of railroad track.
H-8 (SSE, 8.13 Miles) - (West bank) Located on pole in front of Hahnville High School.
P-6 (WNW, 5.58 Miles) - (West bank) Located on fence at LA 640/railroad track intersection.
Q-5 (NW, 5.01 Miles) - (West bank) Located on pole on LA 18 across from Mississippi River marker 137.
12
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An outer ring of stations, 1 in 10 of the R-6 (NNW, 5.52 Miles) - (East bank) Located on Quarterly Gamma dose quarterly.
meteorological sectors in the 6 to 8 km fence on LA 3223 near railroad crossing.
ranges from the site.
TLDs The balance of the stations to be in F-9 (ESE, 8.18 Miles) - (East bank) Located on special interest areas such as fence north of railroad tracks on Jonathan Street.
population centers, nearby residences, schools, and in 1 or 2 areas to serve G-8 (SE, 7.74 Miles) - (West bank) Located on as control stations.
back fence of Luling Entergy Office.
E-15 (E, 11.7 Miles) - (East bank) Located on fence on Alliance Avenue.
13
Annual Radiological Environmental Operatina Report 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation The balance of the stations to be in J-15 (S, 11.7 Miles) - (West bank) Located on pole Quarterly Gamma dose quarterly.
special interest areas such as near LA 631/Hwy 90 intersection in Des Allemands.
population centers, nearby residences, schools, and in 1 or 2 areas to serve E-30 (E, 25.2 Miles) - (West bank) Located at as control stations.
entrance to Entergy office on Delaronde St. in Algiers.
(Control)
Waterborne Surface Water One sample upstream One sample downstream SWP-7 (WNW, 7.37 Miles) - (West bank) Located at St. John Parish Waterworks in Edgard. (Control)
SWF-2 (ESE, 1.51 Miles) - (West bank) Located at Dow Chemical Plant drinking water canal.
SWE-5 (E, 4.59 Miles) - (East bank) Located at St.
Charles Parish Waterworks in New Sarpy.
SWK-1 (SSW, 0.49 Miles) - (West bank) Located at 40 Arpent Canal south of the plant.
Composite sample over one quarter period.
Gamma isotopic analysis quarterly.
Composite for tritium analysis quarterly.
14
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Waterborne Drinking Water One sample upstream DWP-7 (WNW, 7.37 Miles) - (West bank) Located Composite sample over one 1-131 analysis on each at St. John Parish Waterworks in Edgard. (Control) month period when 1-131 composite when the dose DWF-2 (ESE, 1.51 Miles) - (West bank) Located at analysis is performed, quarterly calculated for the consumption of One sample downstream Dow Chemical Plant drinking water canal.
composite otherwise.
the water is greater than one DWE-5 (E, 4.59 Miles) - (East bank) Located at St.
mrem per year. Composite for Charles Parish Waterworks in New Sarpy.
gross beta and gamma isotopic analyses quarterly. Composite for tritium analysis quarterly.
Sediment from Shoreline One sample upstream SHWQ-6 (NW, 5.99 Miles) - (East bank) Located on LA 628 east of Reserve ferry landing. (Control)
Annually Gamma isotopic analysis annually.
SHWE-3 (E, 2.99 Miles) - (West bank) Located at One sample downstream Foot Ferry landing on LA 18.
SHWK-1 (SSW, 0.49 Miles) - (West bank) Located at 40 Arpent Canal south of plant.
Ingestion Milk Samples from milking animals in the MKE-3 (E, 2.35 Miles) - (West bank) Located at the Quarterly Gamma isotopic and 1-131 three locations within 5 km distance Zeringue's house on LA 18 in Taft.
having the highest dose potential. If analysis quarterly.
there are none, then, one sample from milking animals in each of the three areas between 5 to 8 km distant where doses are calculated to be greater than 1 mrem per year.
15
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Ingestion Milk One sample from milking animals at a MKA-31 (N, 31.2 Miles) - (East bank) Located at Quarterly Gamma isotopic and 1-131 control location 15 - 30 km distant and 18736 Sisters Road, Ponchatoula, LA. (Control) analysis quarterly.
in the least prevalent wind direction.
Fish and Invertebrates One sample of each commercially and FH-2 (Distance/Direction Not Applicable) -
Sample in season, or Gamma isotopic analysis recreational important species in vicinity Downstream of the plant discharge structure.
annually if they are not of plant discharge area.
seasonal FH-3 (Distance/Direction Not Applicable) -
(Westbank) Waterways downstream of plant discharge directed to 40 Arpent Canal.
One sample of same species in area FH-1 (Distance/Direction Not Applicable) -
not influenced by plant discharge.
Upstream of the plant intake structure. (Control)
Broadleaf Samples of one to three different kinds BLQ-1 (NW, 0.83 Miles) - (West bank) Located near Quarterly Gamma isotopic and 1-131 of broadleaf vegetation grown nearest air sample station APQ-1.
analysis.
each of two different off-site locations of highest predicted annual average BLB-1 (NNE, 0.81 Miles) - (East bank) Located west ground level D/Q if milk sampling is not of Little Gypsy on LA 628.
performed.
One sample of each of the similar BLE-20 (E, 19.7 Miles) - (West bank) Located on broadleaf vegetation grown 15 - 30 km property of Nine Mile Point in Westwego. (Control) distant in the least prevalent wind direction if milk sampling is not performed.
16
Annual Radiological Environmental Ooerating Report 2013 Waterford 3 Steam Electric Station FIGURE 1-1 17
Annual Radiological Environmental ODerating Reg~ort 2013 Waterford 3 Steam Electric Station FIGURE 1-2 18
Annual Radiological CmA~r~ntvnn~aI Arnaroin Darw~
2013 Waterfbrd 3 Steam Elecft Stabon FIGURE 1-3 N
A
- ml Type 10 0
10 20 Miles K
J 19
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station 2.0 Interpretation and Trends of Results 2.1 Air Particulate and Radioiodine Sample Results Samples of airborne particulate and radioiodine were collected at four indicator locations and one control location and analyzed for gross beta radionuclides, Iodine-131 and gamma radionuclides (quarterly air particulate filter composites only). W3 did not detect any gamma radionuclides in the quarterly air particulate composites or Iodine-1 31 in the radioiodine cartridges during the reporting period as has been the case in previous years. Indicator gross beta air particulate results for 2013 were similar to those background levels obtained in previous years of the operational REMP andq well below preoperational levels as seen below. Results are reported as annual average pCi/mi Monitoring Period Result Preoperational 0.080 1983-2012 0.020 2013 0.019 Table 3.1, which includes gross beta concentrations for 2013, provides a comparison of the indicator and control means. It further emphasizes that the airborne pathway continues to remain at background levels. In addition, as shown in Attachment 2, the standard "t" test was used to compare average gross beta activity from each indicator station to the average gross beta activity at the control station. The results from this test show the average activity detected at all indicator stations is statistically the same as the average activity detected at the control station. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2013.
2.2 Thermoluminescent Dosimetry Sample Results The average exposure rates during 2013 are consistent with those from the preoperational program and the previous five years of operation as seen in Figure 2-1. In particular, the preoperational survey indicates that exposure rates ranged between 11 and 33 mrem/standard quarter with an average of 20 mrem/standard quarter. The range during the previous five years of operation was 8 to 16 mrem/standard quarter with an average exposure rate of 12 mrem/standard quarter.
A comparison of the indicator results to the control results, as seen in Table 3.1, shows that the average indicator is slightly higher than that of the control. As shown in Attachment 1, Table 2.1, several indicator locations are higher than the control by a few mrem with a maximum difference of six mrem.
As shown in Attachment 2, Table 2.1, the standard "t" test was used to compare average exposure rates for TLD stations located in groups 0-2 miles and 2-5 miles from the plant to those
> 5 miles. The results indicate that the average exposure rates 0-2 miles from the plant are statistically the same as >5 miles while those 2-5 miles are statistically higher.
The differences between indicator locations and the control, and TLD stations grouped by distance from the plant are expected due to a variety of factors not related to W3 plant operations that can affect background radiation in the vicinity of each TLD station. Direct radiation measurements at each TLD station have remained statistically the same in 2013 as previous years of operation as evidenced on Attachment 2, Table 2.2. In addition, Radiological Gaseous Effluents for 2013 were only a small fraction of the limits and are not expected to have any impact on environmental TLD measurements.
20
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station 2.3 Water Sample Results Analytical results for 2013 drinking/surface water samples were similar to those reported in previous years.
DrinkinglSurface Water Drinking water samples also serve as surface water samples for W3. Therefore, monthly and quarterly gamma spectroscopy and tritium analyses of drinking water also satisfy the surface water sampling requirement.
Composite drinking/surface water samples were collected from two indicators and one control location and analyzed for Iodine-1 31, gamma radionuclides and tritium. Results indicate that all measurements were below the calculated LLDs.
Although gross beta was detected in the drinking/surface water samples, results for the indicator locations were below preoperational years and slightly above previous operational years as seen below. Results are reported as annual average pCi/I.
Monitoring Period Result Preoperational 7.0 1983-2012 4.7 2013 5.1 Table 3.1, which includes gross beta concentrations for 2013, provides a comparison of the indicator and control means. It shows that the waterborne pathway continues to remain at background levels. In addition, as shown in Attachment 2, the standard "t" test was used to compare average gross beta activity from indicator stations to the average gross beta activity from the control station. The results from the test show the average activity detected at one indicator station is statistically the same as the average activity detected at the control station and one indicator station is statistically higher than the mean for the control location. Results are consistent with historical data stated above. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2013.
Surface Water Surface water samples were collected from one indicator location and analyzed for gamma radionuclides and tritium. Results indicate that all measurements were below the calculated LLDs. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2013.
2.4 Sediment Sample Results Sediment samples were collected from two indicator locations and one control location and analyzed for gamma radionuclides. Results indicate that all measurements were below the calculated LLDs. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2013.
21
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station 2.5 Milk Sample Results Since milk samples for indicator location MKE-3 were unavailable for all quarters of 2013, broad leaf vegetation sampling was performed as required by TRM Table 3.12-1. Broad leaf vegetation results are in section 2.7. Milk samples were collected from one control location and analyzed for Iodine-1 31 and gamma radionuclides. Results indicate that all measurements were below the calculated LLDs. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2013.
2.6 Fish Sample Results Fish samples were collected from two indicators and one control location and analyzed for gamma radionuclides. Results indicate that all measurements were below the calculated LLDs.
Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2013.
2.7 Broadleaf Vegetation Sample Results Broadleaf vegetation samples were collected from two indicators and one control location and analyzed for Iodine-1 31 and gamma radionuclides. Results indicate that all measurements were below the calculated LLDs. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2013.
2.8 Land Use Census Results In compliance with the Waterford 3 0DCM and TRM, the land use census was conducted September 24 - September 26, 2012. The nearest residence, garden, beef cow, food product and milk animal in each sector within a five mile radius of the plant was located by visual inspection and verbal inquiry.
One new residence location (sector R) and four new garden locations (sectors D, G, N, and R) were identified in 2012. Milk cow, goat, beef cow and food product locations remained unchanged for 2012. Based upon the locations identified in this survey, the locations identified in previous surveys and the locations currently being used to calculate dose commitments from liquid and gaseous effluents released from W3, no REMP sampling location changes are necessary. Results of the 2012 biennial census are shown in Table 2.1.
2.9 Interlaboratory Comparison Results Teledyne Brown Engineering, Inc. analyzed interlaboratory comparison samples for W3 to fulfill the requirements of Section 5.7.2 of the ODCM. Attachment 1 contains these results.
22
Annual Radiological Environmental ODeratina ReDort 2013 Waterford 3 Steam Electric Station TABLE 2.1 Biennial Land Use Census Results Sector Direction Distance from Plant in Miles Milk Beef Food Residence Garden Cows Cows Goats Products A
N 1.3 1.7 A
4.8 A
4.1 B
NNE 1.1 1.3 A
A A
1.3 C
NE 0.9 1.0 A
A A
A D
ENE 0.9 3.2 A
A A
A E
E 2.2 2.2
- 2.3 2.3
- 3.2 0.3 F
ESE 3.1 2.2 A
2.3 A
0.3 G
SE 4.0 4.1 A
2.4 A
0.3 H
SSE A
A A
A A
0.3 J
S A
A A
A A
0.5 K
SSW A
A A
A A
0.5 L
SW A
A A
A A
0.5 M
WSW A
1.4 A
1.2 A
0.5 N
W 1.0 1.1 A
1.0 A
0.6 P
WNW 0.9 0.9 A
A A
0.6 Q
NW 0.9 1.0 A
A A
0.6 R
NNW 3.0 3.0 A
4.9 A
2.6 A Indicates that nothing was found Waterford 3 in the sector within a five mile radius of
- Animals were located at this distance from Waterford 3, but the milk is not currently used for human consumption
- Samples are being obtained from animals at this location (MKE-3) for REMP 23
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station I
I FIGURE 2-1 TLD Radiation Dose Comparison By Year I
SrE 40 35 30 25 20 15 10 40 35 30 25 20 15 10 5
0 5
0 YEAR 24
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station 3.0 Radiological Environmental Monitoring Program Summary 3.1 2013 Program Results Summary Table 3.1 summarizes the 2013 REMP results. W3 did not use values reported as less than the lower limit of detection (< LLD) when determining ranges and means for indicator and control locations.
25
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station TABLE 3.1 Radiolo-gical Environmental Monitoring Program Summary Name of Facility: Waterford 3 SES Docket No: 50-382 Location of Facility: St. Charles. Louisiana Reporting Period: January - December 2013 Sample Type Type & Number LLD b Indicator Locations Location with Highest Annual Control Number of (Units)
Of Analyses a Mean ( F ) c Mean Locations Nonroutine
[Range]
Mean (F) c Results e
[ Range ]
Mean ( F ) c Location d
[ Range ]
Airborne Particulates GB 130 0.01 0.019 ( 102 /104)
APF-1 0.020 ( 25 / 26) 0.020 ( 26 / 26 0
(pCi/m 3 )
[0.010 - 0.033]
(ESE, 0.35 mi.)
[0.012 - 0.033]
[0.011 - 0.035]
GS 20 Cs-1 34 0.05
<LLD N/A N/A
<LLD 0
Cs-1 37 0.06
<LLD N/A N/A
<LLD 0
Airborne Iodine 1-131 130 0.07
<LLD N/A N/A
<LLD 0
( pCi/m3)
Indicator TLDs Gamma 120 (f) 12(113/120)
F-4 14(4/4)
N/A 0
( mrem/Std. Qtr)
[8.8-15.1]
(ESE, 3.53 mi.)
[14.0- 15.1 ]
Control TLDs Gamma 4
(f)
N/A N/A N/A 10 (4 / 4) 0 (mremlStd. Qtr)
[9.4 - 10.1]
26
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station TABLE 3.1 Radiological Environmental Monitoring Program Summary Name of Facility: Waterford 3 SES Docket No: 50-382 Location of Facility: St. Charles, Louisiana Reporting Period: January - December 2013 Sample Type Type & Number LLD b Indicator Location Location with Highest Annual Mean Control Number of (Units) of Analyses a Mean ( F C
Locations Nonroutine
[Range]
Mean (F) c Results e
[ Range]
Mean ( F ) C Location d
[ Range ]
Surface Water &
Gross Beta 12
- 45.
(57/8)
DWF/SWF-2 6.2(3/4) 4.3(4/4) 0 Drinking Water
[3.7 - 6.7]
(ESE, 1.51 mi.)
[5.6 - 6.7]
[2.9 - 5.2]
(pCi/I) 1-131 40 1
<LLD N/A N/A
<LLD 0
H-3 12 2000
<LLD N/A N/A
<LLD 0
GS 12 Mn-54 15
<LLD N/A N/A
<LLD 0
Fe-59 30
<LLD N/A N/A
<LLD 0
Co-58 15
<LLD N/A N/A
<LLD 0
Co-60 15
<LLD N/A N/A
<LLD 0
Zn-65 30
<LLD N/A N/A
<LLD 0
Zr-95 15
<LLD N/A N/A
<LLD 0
Nb-95 15
<LLD N/A N/A
<LLD 0
Cs-1 34 15
<LLD N/A N/A
<LLD 0
Cs-1 37 18
<LLD N/A N/A
<LLD 0
Ba-140 15
<LLD N/A N/A
<LLD 0
La-140 15
<LLD N/A N/A
<LLD 0
27
Annual Radiological Environmental Operatinq Report 2013 Waterford 3 Steam Electric Station TABLE 3.1 Radiological Environmental Monitoring Program Summary Name of Facility: Waterford 3 SES Docket No: 50-382 Location of Facility: St. Charles, Louisiana Reporting Period: January - December 2013 Sample Type Type &
LLD b Indicator Locations Location with Highest Annual Mean Control Locations Number of (Units)
Number Mean (F) c Mean ( F ) c Nonroutine of Analyses a
[Range ]
[Range]
Results e Mean ( F) c Location d
[Range I Surface Water H-3 4
3000
<LLD N/A N/A N/A 0
(pCi/I)
GS 13 Mn-54 15
<LLD N/A N/A N/A 0
Fe-59 30
<LLD N/A N/A N/A 0
Co-58 15
<LLD N/A N/A N/A 0
Co-60 15
<LLD N/A N/A N/A 0
Zn-65 30
<LLD N/A N/A N/A 0
Zr-95 15
<LLD N/A N/A N/A 0
Nb-95 15
<LLD N/A N/A N/A 0
Cs-1 34 15
<LLD N/A N/A N/A 0
Cs-1 37 18
<LLD N/A N/A N/A 0
Ba-140 15
<LLD N/A N/A N/A 0
La-140 15
<LLD N/A N/A N/A 0
1-131 15
<LLD N/A N/A N/A 0
Shoreline GS 3
Sediment Cs-1 34 150
<LLD N/A N/A
<LLD 0
(pCi/kg dry)
Cs-1 37 180
<LLD N/A N/A
<LLD 0
28
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station TABLE 3.1 Radiological Environmental Monitoring Program Summary Name of Facility: Waterford 3 SES Docket No: 50-382 Location of Facility: St. Charles. Louisiana Reporting Period: January - December 2013 Sample Type Type & Number LLD b Indicator Location Location with Highest Annual Mean Control Number of (Units) of Analyses a Mean ( F) c Locations Nonroutine
[Range]
Mean (F) c Results e
[Range ]
Mean (F ) c Location d
[Range ]
Milk 1-131 4
1<
LLD N/A N/A
<LLD 0
(pCi/I)
GS 4
Cs-1 34 15
< LLD N/A N/A
<LLD 0
Cs-1 37 18
< LLD N/A N/A
<LLD 0
Ba-140 15
< LLD N/A N/A
<LLD La-140 15
< LLD N/A N/A
<LLD 0
0 Fish GS 12 (pCi/kg wet)
Mn-54 130
<LLD N/A N/A
<LLD 0
Fe-59 260
<LLD N/A N/A
<LLD 0
Co-58 130
<LLD N/A N/A
<LLD 0
Co-60 130
<LLD N/A N/A
<LLD 0
Zn-65 260
<LLD N/A N/A
<LLD 0
Cs-1 34 130
<LLD N/A N/A
<LLD 0
Cs-1 37 150
<LLD N/A N/A
<LLD 0
Broadleaf Vegetation 1-131 12 60
<LLD N/A N/A
<LLD 0
(pCi/kg wet)
GS 12 Cs-1 34 60
<LLD N/A N/A
<LLD 0
Cs-1 37 80
<LLD N/A N/A
<LLD 0
a GB = Gross beta; 1-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.
b LLD = required lower limit of detection based on Waterford 3 TRM.
c Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).
d Locations are specified (1) by name and (2) degrees relative to reactor site.
e Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.
LLD is not defined in Waterford 3 TRM.
29
Annual Radiological Environmental Ooeratina Reoort 2013 Waterford 3 Steam Electric Station 2013 Radiological Monitoring Report Summary of Monitoring Results 30
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station TABLE OF CONTENTS TABLE 1.1 TABLE 1.2 TABLE 1.3 TABLE 2.1 TABLE 3.1 TABLE 3.2 TABLE 3.3 TABLE 3.4 TABLE 3.5 TABLE 4.1 TABLE 5.1 TABLE 6.1 TABLE 7.1 TABLE 8.1 AIR PARTICULATE FILTER RADIOIODINE CARTRIDGE AIR PARTICULATE FILTER THERMOLUMINESCENT DOSIMETERS DRINKINGISURFACE WATER DRINKING/SURFACE WATER DRINKING/SURFACE WATER DRINKING/SURFACE WATER SURFACE WATER SEDIMENT MILK FISH BROADLEAF VEGETATION INTERLABORATORY COMPARISON 32 33 34 35 36 37 38 39 40 41 42 43 44 45 31
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 1.1 Sample Type: Air Particulate Filter Analysis: Gross Beta Units: pCi/m3 End Date APF-1 APQ-1 APP-1 APC-1 APE-30 (Indicator)
(Indicator)
(Indicator)
(Indicator)
(Control)
Required LLD 0.01 01-07-13 01-21-13 02-04-13 02-18-13 03-04-13 03-18-13 04-01-13 04-15-13 04-29-13 05-13-13 05-28-13 06-10-13 06-24-13 07-08-13 07-22-13 08-05-13 08-19-13 09-03-13 09-16-13 09-30-13 10-14-13 10-28-13 11-11-13 11-25-13 12-09-13 12-22-13 0.028 0.019 0.029 0.018 0.023 0.020 0.024 0.019 0.017 0.014 0.021 0.012 0.020 0.014 0.014 0.023 (1) 0.013 0.023 0.018 0.018 0.033 0.023 0.019 0.021 0.025 0.01 0.028 0.017 0.030 0.014 0.019 0.022 0.019 0.014 (2) 0.014 0.018 0.011 0.016 0.013 0.014 0.022 0.015 0.014 0.025 0.021 0.015 0.023 0.024 0.018 0.022 0.029 0.01 0.028 0.016 0.028 0.017 0.024 0.022 0.020 0.018 0.015 0.013 0.021 0.010 0.015 0.014 0.011 0.023 0.013 0.013 0.024 0.019 0.014 0.027 0.020 0.019 0.017 0.025 0.01 0.030 0.015 0.030 0.017 0.017 0.021 0.020 0.019 0.016 0.012 0.018 0.013 0.014 0.012 0.013 0.022 0.017 0.014 0.021 0.023 0.015 0.026 0.022 0.018 0.015 0.026 0.01 0.035 0.017 0.028 0.016 0.021 0.023 0.023 0.017 0.018 0.018 0.021 0.011 0.016 0.016 0.013 0.023 0.015 0.013 0.025 0.018 0.017 0.027 0.022 0.019 0.019 0.029 (1) Low volume due to sample pump trip (2)
Low volume due to loss of electrical power 32
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 1.2 Sample Type: Radiolodine Cartridge Analysis: Iodine-1 31 Units: pCi/ms End Date APF-1 APQ-1 APP-1 APC-1 APE-30 (Indicator)
(Indicator)
(Indicator)
(Indicator)
(Control)
Required LLD 0.07 01-07-13 01-21-13 02-04-13 02-18-13 03-04-13 03-18-13 04-01-13 04-15-13 04-29-13 05-13-13 05-28-13 06-10-13 06-24-13 07-08-13 07-22-13 08-05-13 08-19-13 09-03-13 09-16-13 09-30-13 10-14-13 10-28-13 11-11-13 11-25-13 12-09-13 12-22-13
< 0.015
< 0.0 12
<0.036
< 0.014
< 0.030
<0.011
< 0.064
< 0.012
< 0.028
< 0.013
< 0.020
< 0.013
< 0.035
<0.017
< 0.063
< 0.021 (1)
< 0.040
< 0.040
< 0.050
<0.015
< 0.035
< 0.010
< 0.040
< 0.044
<0.019 0.07
< 0.023
< 0.027
< 0.013
< 0.030
< 0.025
< 0.022
< 0.053
< 0.025 (2)
< 0.030
< 0.009
<0.019
< 0.028
< 0.033
< 0.050
< 0.044
< 0.027
< 0.038
< 0.038
< 0.047
< 0.033
< 0.029
< 0.024
< 0.038
< 0.042
< 0.043 0.07
< 0.023
< 0.027
< 0.030
< 0.030
< 0.008
< 0.022
< 0.053
< 0.025
< 0.023
< 0.026
<0.016
<0.019
<0.012
< 0.033
< 0.051
< 0.044
< 0.027
< 0.038
< 0.036
< 0.045
< 0.032
< 0.029
< 0.023
< 0.037
< 0.043
< 0.042 0.07
< 0.022
< 0.026
< 0.029
< 0.029
< 0.024
< 0.021
<0.019
< 0.024
< 0.029
< 0.025
< 0.016
< 0.019
< 0.028
< 0.033
<0.0 19
<0.044
< 0.027
< 0.037
< 0.036
< 0.017
< 0.032
< 0.029
< 0.023
< 0.037
< 0.043
< 0.042 0.07
< 0.037
< 0.033
< 0.033
< 0.032
< 0.026
< 0.023
< 0.055
< 0.026
< 0.009
< 0.026
< 0.016
< 0.020
< 0.029
< 0.034
< 0.052
< 0.045
< 0.028
< 0.016
< 0.015
< 0.046
< 0.033
< 0.012
< 0.024
<0.016
< 0.023
< 0.043 (1) Low volume due to sample pump trip (2) Low volume due to loss of electrical power 33
Annual Radiological Environmental Ooeratina ReDort 2013 Waterford 3 Steam Electric Station Table 1.3 Sample Type: Air Particulate Filter Analysis: Gamma Isotopic Units: pCi/m 3 Location Quarterly Cs-1 34 Cs-1 37 Composite Required LLD 0.05 0.06 APF-1 (Indicator) 1st
< 0.004
< 0.002 APQ-1 (Indicator) 1st
< 0.002
< 0.002 APP-1 (Indicator) 1st
< 0.002
< 0.002 APC-1 (Indicator) 1st
< 0.002
< 0.002 APE-30 (Control) 1st
< 0.003
< 0.002 APF-1 (Indicator) 2nd
< 0.004
< 0.004 APQ-1 (Indicator) 2nd
< 0.004
< 0.003 APP-1 (Indicator) 2nd
< 0.004
< 0.003 APC-1 (Indicator) 2nd
< 0.002
< 0.002 APE-30 (Control) 2nd
< 0.003
< 0.002 APF-1 (Indicator) 3rd
< 0.003
< 0.002 APQ-1 (Indicator) 3rd
< 0.004
< 0.003 APP-1 (Indicator) 3rd
< 0.002
< 0.002 APC-1 (Indicator) 3rd
< 0.003
< 0.003 APE-30 (Control) 3rd
< 0.004
< 0.003 APF-1 (Indicator) 4th
< 0.004
< 0.003 APQ-1 (Indicator) 4th
< 0.002
< 0.002 APP-1 (Indicator) 4th
< 0.003
< 0.003 APC-1 (Indicator) 4th
< 0.003
< 0.003 APE-30 (Control) 4th
< 0.007
< 0. 007 34
Annual Radiological Environmental Operatina Report 2013 Waterford 3 Steam Electric Station Table 2.1 Sample Type: Thermoluminescent Dosimeters Analysis:
Gamma Dose Units: mrem/Std. Qtr.
Indicator Locations Station 1st Qtr '13 2nd Qtr '13 3rd Qtr '13 4th Qtr '13 Annual Mean '13 A-2 A-5 B-1 B-4 C-1 D-2 D-5 E-1 E-5 E-15 F-2 (1) F-4 F-9 G-2 G-4 G-8 H-2 H-8 J-2 J-1 5 K-1 L-1 M-1 N-1 P-1 P-6 Q-1 Q-5 R-1 R-6 13 (3) 13 14 9
13 13 12 13 10 12 14 13 10 11 11 12 12 10 12 11 13 10 13 9
13 12 12 9
11 12 13 11 13 12 13 13 14 9
9 (2) 13 11 12 11 11 12 13 10 10 12 12 14 14 12 12 10 11 11 11 10 11 12 12 (2)
(2) 10 10 13 13 11 11 15 15 10 10 14 14 10 10 13 13 13 13 13 13 10 10 11 11 Control Location 2nd Qtr'13 3rd Qtr'13 14 (2) 14 14 10 13 (2) 12 13 11 13 15 13 11 12 11 12 14 11 14 11 15 11 (2) 10 14 13 14 10 11 Station 1st Qtr '13 4th Qtr '13 Annual Mean '13 E-30 10 9
10 10 10 (1)
(2)
(3)
Location with highest annual mean No data - TLDs missing at time of exchange Damaged TLDs (wet) 35
Annual Radiological Environmental Operatinq Report 2013 Waterford 3 Steam Electric Station Table 3.1 Sample Type: Drinking/Surface Water Analysis: Gross Beta Units: pCi/I Quarterly DWF/SWF-2 DWEISWE-5 DWP/SWP-7 Composite (Indicator)
(Indicator)
(Control)
Required LLD 4
4 4
1 st
< 2.07 3.72 4.16 2na 5.61 3.93 5.16 3rd 6.74 4.21 2.90 4th 8.15 5.09 5.00 36
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 3.2 Sample Type: Drinking/Surface Water Analysis: Iodine-131 Units: pCi/I Collection SWK-1 DWFISWF-2 DWEISWE-5 DWP/SWP-7 Date (Indicator)
(Indicator)
(Indicator)
(Control)
LLD (1) 01-02-13 01-30-13 02-27-13 03-27-13 04-24-13 05-22-13 06-19-13 07-17-13 08-13-13 09-11-13 10-08-13 11-05-13 12-03-13 12-31-13 15 I
1
<2.44
< 2.36
<3.11
< 4.03
<5.12
< 5.08
< 3.73
< 3.45
< 5.07
< 5.69
<5.10
< 4.89
< 4.05
<0.72
< 0.23
<0.18
< 0.24
< 0.58
< 0.70
< 0.52
< 0.48
< 0.66
< 0.81
< 0.70
< 0.76-
< 0.65
< 0.66
< 0.21
< 0.21
< 0.25
<0.11
< 0.67
< 0.77
< 0.69
< 0.85
< 0.68
< 0.80
< 0.64
< 0.97
< 0.75 I
< 0.23
< 0.21
< 0.20
< 0.74
< 0.65
< 0.56
< 0.49
< 0.63
< 0.67
< 0.66
< 0.86
< 0.74
< 0.69 (1) Duplicate sample 37
Annual Radiological Environmental ODeratina Reoort 2013 Waterford 3 Steam Electric Station Table 3.3 Sample Type: Drinkinci/Surface Water Analysis: Gamma Isotopic Units: pCi/I Location Collection Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 Cs-1 34 Cs-1 37 Ba-140 La-140 Date Required LLD 15 15 30 15 30 15 15 15 18 15 15 DWF/SWF-2 (Indicator) 1st
< 0.93
< 1.06
< 2.13
< 0.88
< 1.97
< 1.16
< 1.97
< 0.92
< 0.95
< 10.20
< 2.61 DWE/SWE-5 (Indicator) 1st
< 1.21
< 1.41
< 3.16
< 1.28
< 2.66
< 1.45
< 2.72
< 1.22
< 1.34
< 13.20
< 3.99 DWP/SWP-7 (Control) 1st
< 1.01
< 0.92
< 2.23
< 0.83
< 1.97
< 1.04
< 1.75
< 0.90
< 0.95
< 10.10
< 3.77 DWF/SWF-2 (Indicator) 2nd
< 3.29
< 3.09
< 6.96
< 2.86
< 6.13
< 3.29
< 5.98
< 3.26
< 3.46
< 14.20
< 4.48 DWE/SWE-5 (Indicator) 2nd
< 2.61
< 2.82
< 5.85
< 3.61
< 6.45
< 2.84
< 4.89
< 2.94
< 3.36
< 12.40
< 4.91 DWP/SWP-7 (Control) 2nd
< 2.89
< 2.81
< 5.32
< 3.03
< 6.45
< 3.02
< 4.97
< 2.83
< 3.09
< 14.50
< 3.20 DWFISWF-2 (Indicator) 3rd
< 2.31
< 2.40
< 4.70
< 2.10
< 4.71
< 2.39
< 4.48
< 1.86
< 2.56
< 12.60
< 2.79 DWE/SWE-5 (Indicator) 3rd
< 2.55
< 2.42
< 4.64
< 2.09
< 5.04
< 2.76
< 4.97
< 2.39
< 2.45
< 12.30
< 5.10 DWPISWP-7 (Control) 3rd
< 2.12
< 2.73
< 4.17
< 2.27
< 4.14
< 2.60
< 3.73
< 2.37
< 2.87
< 13.10
< 2.34 DWF/SWF-2 (Indicator) 4th
< 2.63
< 2.79
< 5.64
< 3.10
< 4.55
< 2.35
< 3.81
< 2.33
< 3.04
< 13.60
< 4.15 DWEISWE-5 (Indicator) 4th
< 2.03
< 1.78
< 4.39
< 1.70
< 5.48
< 2.47
< 3.47
< 2.16
< 2.14
< 10.80
< 2.54 DWP/SWP-7 (Control) 4th
< 2.41
<1.44
< 3.46
< 2.10
< 6.00
< 2.44
< 4.17
< 2.26
< 2.36
< 13.90
< 5.83 38
Annual Radiological Environmental ODerating ReDort 2013 Waterford 3 Steam Electric Station Table 3.4 Sample Type: Drinkinca/Surface Water Analysis: Tritium Units: pCi/I Quarter DWF/SWF-2 DWE/SWE-5 SWK-1 DWP/SWP-7 (Indicator)
(Indicator)
(Indicator)
(Control)
Reauired LLD
-1 2000 2000 3000 2000 1st
< 607.00
< 684.00
< 578.89
< 680.00 2 nd
< 566.00
< 650.48
< 593.00
< 572.00 3rd
< 622.00
< 621.69
< 609.00
< 613.00 4 th
< 635.00
< 578.74
< 633.00
< 625.00 39
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 3.5 Sample Type: Surface Water Analysis: Gamma Isotopic Units: pCi/I Location Collection Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 Cs-134 Cs-137 Ba-140 La-140 Date Required LLD 1
15 15 30 15 30 15 15 15 18 15 15 SWK-1 01-30-13
< 1.32
< 1.34
< 2.53
< 1.37
< 2.70
< 1.42
< 2.46
< 1.25
< 1.37
< 6.74
< 2.36 (Indicator) 02-27-13
< 1.44
< 1.47
< 3.17
< 1.45
< 2.99
< 1.62
< 2.66
< 1.48
< 1.59
< 6.67
< 2.10 03-27-13
< 2.16
< 2.24
< 4.62
< 2.52
< 4.29
< 2.26
< 3.73
< 1.99
< 2.31
< 9.99
< 3.50 04-24-13
< 2.34
< 2.59
< 5.03
< 2.81
< 5.02
< 2.67
< 3.68
< 2.47
< 2.61
< 10.90
< 3.94 05-22-13
< 2.70
< 3.07
< 6.01
< 2.94
< 6.54
< 2.95
< 5.21
< 3.03
< 2.76
< 13.90
< 5.03 06-19-13
< 4.18
< 4.10
< 7.47
< 3.59
< 8.26
< 3.88
< 7.12
< 3.93
< 4.58
< 14.40
< 4.90 07-17-13
< 3.20
< 3.46
< 6.55
< 3.68
< 7.46
< 3.75
< 5.90
< 3.39
< 3.56
< 14.70
< 4.35 08-13-13
< 1.94
< 2.02
< 4.50
< 2.01
< 4.49
< 2.10
< 3.73
< 1.88
< 2.24
< 10.30
< 3.48 09-11-13
<3.05
<3.28
< 7.08
<3.39
< 6.28
<3.04
<6.37
<2.76
<3.49
<13.90
<5.04 10-08-13
< 2.38
< 2.66
< 5.46
< 2.84
< 4.26
< 2.84
< 4.59
< 2.67
< 2.68
< 13.60
< 4.00 11-05-13
<2.44
<2.40
< 4.73
<2.49
< 5.02
<2.72
<4.26
<2.52
<2.60
<13.30
<4.16 12-03-13
< 2.89
< 2.73
< 5.48
< 2.39
< 5.45
< 3.06
< 4.68
< 2.79
< 2.73
< 12.10
< 3.56 12-31-13
< 2.56
< 2.51
< 5.57
< 3.06
<.4.82
< 2.70
< 4.08
< 2.72
< 2.98
< 13.50
< 3.55 40
Annual Radiological Environmental Operatinc Report 2013 Waterford 3 Steam Electric Station Table 4.1 Sample Type: Sediment Analysis: Gamma Isotopic Units: pCi/kg (dry)
Location Collection Cs-134 Cs-137 Date Required LLD 150 180 SHWK-1 (Indicator) 03-04-13
< 30.1
< 32.9 SHWE-3 (Indicator) 03-04-13
< 25.5
< 46.2 SHWQ-6 (Control) 03-04-13
< 39.9
< 39.6 41
Annual Radiological Environmental ODeratina Reoort 2013 Waterford 3 Steam Electric Station Table 5.1 Sample Type: Milk Analysis: iodine-131 and Gamma Isotopic Units: pCi/I Location Collection 1-131 Cs-134 Cs-137 Ba-140 La-140 Date Required LLD 1
15 18 MKE-3 (Indicator)
MKA-31 (Control)
(1)03-19-13 (1)06-13-13 (1)09-12-13 (1) 12-12-13 03-19-13 06-13-13 09-12-13 12-12-13 n/a n/a n/a n/a
< 0.36
< 0.35
< 0.29
< 0.74 n/a n/a n/a n/a
< 2.67
< 3.09
< 2.70
< 1.44 n/a n/a n/a n/a
< 3.12
< 3.85
< 3.36
< 2.76 15 n/a n/a n/a n/a 9.95
< 14.20
< 12.30 8.55 15 n/a n/a n/a n/a
<3.11
< 4.30
< 4.02
< 2.32 (1) Sample not available. Cows not producing enough milk. See page 2 for details.
42
Annual Radiological Environmental ODeratina ReDort 2013 Waterford 3 Steam Electric Station Table 6.1 Sample Type: Fish Analysis: Gamma Isotopic Units: pCi/kg (wet)
Location Collection Species Mn-54 Co-58 Fe-59 Co-60 Zn-65 Cs-134 Cs-137 Date Required LLD 130 130 260 130 260 130 150 FH-1 (Control) 10-08-13 Buffalo
< 51.9
< 50.0
< 160.0
< 49.8
< 105.0
< 52.5
< 52.0 11-05-13 Carp
< 37.7
< 40.4
< 87.3
< 49.1
< 101.0
< 40.7
< 39.2 10-08-13 Catfish
< 57.4
< 55.7
< 198.0
< 62.4
< 121.0
< 55.3
< 49.8 10-08-13 Mullet
< 69.0
< 86.8
< 239.0
< 61.4
< 168.0
< 60.3
< 62.5 FH-2 (Indicator) 11-05-13 Buffalo
< 73.4
< 79.7
< 171.0
< 81.2
< 119.0
< 84.0
< 70.8 11-05-13 Carp
< 56.2
< 51.1
< 130.0
< 63.2
< 118.0
< 56.8
< 51.6 11-05-13 Catfish
< 64.6
< 59.2
< 151.0
< 56.9
< 105.0
< 62.2
< 64.8 11-05-13 Mullet
< 64.8
< 56.2
< 148.0
< 63.9
< 116.0
< 60.8
< 62.4 FH-3 (Indicator) 10-29-13 Buffalo
< 48.1
< 56.8
< 109.0
< 54.9
< 124.0
< 47.8
< 51.8 10-07-13 Carp
< 67.1
< 92.8
< 223.0
< 59.1
< 111.0
< 54.7
< 63.7 10-29-13 Catfish
< 50.6
< 62.7
< 122.0
< 60.6
< 107.0
< 48.2
< 57.6 10-07-13 Mullet
< 66.6
< 70.3
< 166.0
< 61.5
< 129.0
< 62.1
< 64.6 43
Annual Radiological Environmental Operatinq Report 2013 Waterford 3 Steam Electric Station Table 7.1 Sample Type: Broad Leaf Vegetation Analysis: Iodine-131 and Gamma Isotopic Units: pCi/kg (wet)
Location Collection 1-131 Cs-134 Cs-137 Date Required LLD 60 60 80 BLQ-1 (Indicator) 03-14-13
< 55.0
< 18.0
< 21.2 BLQ-1 (Indicator) 06-12-13
< 30.6
< 17.8
< 20.9 BLQ-1 (Indicator) 09-09-13
< 40.6
< 19.0
< 22.8 BLQ-1 (Indicator) 12-11-13
< 56.9
< 35.6
< 40.9 BLB-1 (Indicator) 03-14-13
< 52.6
< 13.9
< 15.0 BLB-1 (Indicator) 06-12-13
< 36.5
< 24.0
< 29.2 BLB-1 (Indicator) 09-09-13
< 36.4
< 17.7
< 18.1 BLB-1 (Indicator) 12-11-13
< 43.7
< 26.1
< 28.6 BLE-20 (Control) 03-14-13
< 38.4
< 26.9
< 29.6 BLE-20 (Control) 06-12-13
< 36.6
< 21.5
< 26.2 BLE-20 (Control) 09-09-13
< 43.5
< 23.3
< 24.9 BLE-20 (Control) 12-11-13
< 48.0
< 34.3
< 39.0 44
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 8.1 Sample Type: Interlaboratory Comparison Analysis: Gross Beta, Iodine-1 31, Tritium and Gamma Isotopic Units: pCi/kg (wet)
ANALYTICS ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES Month/Year ID Number Matrix Nuclide Units Reported Known Ratio (c)
Evaluation Value (a)
Value (b)
TBE/Analytics (d)
March 2013 E10478 Milk 1-131 pCi/L 87.1 100 0.87 A
Ce-141 pCi/L 186 187 0.99 A
Cr-51 pCi/L 463 472 0.98 A
Cs-134 pCi/L 201 214 0.94 A
Cs-137 pCi/L 262 266 0.98 A
Co-58 pCi/L 200 208 0.96 A
Mn-54 pCi/L 215 208 1.03 A
Fe-59 pCi/L 266 252 1.06 A
Zn-65 pCi/L 311 301 1.03 A
Co-60 pCi/L 384 400 0.96 A
E10480 AP Ce-141 pCi 95.3 95.6 1.00 A
Cr-51 pCi 264 241 1.10 A
Cs-134 pCi 123 109 1.13 A
Cs-137 pCi 142 136 1.04 A
Co-58 pCi 112 106 1.06 A
Mn-54 pCi 115 106 1.08 A
Fe-59 pCi 139 129 1.08 A
Zn-65 pCi 163 153 1.07 A
Co-60 pCi 212 204 1.04 A
E10479 Charcoal 1-131 pCi 90.1 92.6 0.97 A
June 2013 E10545 Milk 1-131 pCi/L 92.6 95.5 0.97 A
Ce-141 pCi/L 83.1 90.4 0.92 A
Cr-51 pCi/L 253 250 1.01 A
Cs-134 pCi/L 118 125 0.94 A
Cs-137 pCi/L 143 151 0.95 A
Co-58 pCi/L 87.1 94.0 0.93 A
Mn-54 pCi/L 171 172 0.99 A
Fe-59 pCi/L 125 120 1.04 A
Zn-65 pCi/L 220 217 1.01 A
Co-60 pCi/L 169 175 0.97 A
E10547 AP Ce-141 pCi 56.8 56.7 1.00 A
Cr-51 pCi 168 157 1.07 A
Cs-134 pCi 85.2 78.4 1.09 A
Cs-137 pCi 101 94.6 1.07 A
Co-58 pCi 62.7 58.9 1.06 A
Mn-54 pCi 125 108 1.16 A
Fe-59 pCi 85.7 75.0 1.14 A
Zn-65 pCi 169 136 1.24 W
Co-60 pCi 116 110 1.05 A
E10546 Charcoal 1-131 pCi 86.5 89.7 0.96 A
45
Annual Radiological Environmental Operatinc Report 2013 Waterford 3 Steam Electric Station Table 8.1 Sample Type: Interlaboratory Comparison Analysis: Gross Beta, Iodine-1 31, Tritium and Gamma Isotopic Units: pCi/kg (wet)
Month/Year ID Number Matrix Nuclide Units Reported Known Ratio (c)
Evaluation Value (a)
Value (b)
TBE/Analytics (d)
September 2013 E10647 Milk 1-131 pCi/L 93.9 98.3 0.96 A
Ce-141 pCi/L Not spiked Cr-51 pCi/L 272 277 0.98 A
Cs-134 pCi/L 150 172 0.87 A
Cs-137 pCi/L 125 131 0.95 A
Co-58 pCi/L 105 108 0.97 A
Mn-54 pCi/L 138 139 0.99 A
Fe-59 pCi/L 125 130 0.96 A
Zn-65 pCi/L 264 266 0.99 A
Co-60 pCi/L 187 196 0.95 A
E10672 AP Ce-141 pCi Not spiked Cr-51 pCi 208 223 0.93 A
Cs-134 pCi 143 139 1.03 A
Cs-137 pCi 106 105 1.01 A
Co-58 pCi 97.0 86.5 1.12 A
Mn-54 pCi 116 112 1.04 A
Fe-59 pCi 98.6 105 0.94 A
Zn-65 pCi 219 214 1.02 A
Co-60 pCi 166 158 1.05 A
E10648 Charcoal 1-131 pCi 76.3 71.7 1.06 A
December 2013 E10775 Milk 1-131 pCi/L 89.7 96.1 0.93 A
Ce-141 pCi/L 99.8 110 0.91 A
Cr-51 pCi/L 297 297 1.00 A
Cs-134 pCi/L 129 142 0.91 A
Cs-137 pCi/L 126 126 1.00 A
Co-58 pCi/L 116 112 1.04 A
Mn-54 pCi/L 167 168 0.99 A
Fe-59 pCi/L 117 110 1.06 A
Zn-65 pCi/L 757 741 1.02 A
Co-60 pCi/L 141 147 0.96 A
E10777 AP Ce-141 pCi 85.1 88.0 0.97 A
Cr-51 pCi 278 238 1.17 A
Cs-134 pCi 123 114 1.08 A
Cs-137 pCi 102 101 1.01 A
Co-58 pCi 84.4 89.9 0.94 A
Mn-54 pCi 132 135 0.98 A
Fe-59 pCi 101 88.3 1.14 A
Zn-65 pCi 506 595 0.85 A
Co-60 pCi 118 118 1.00 A
E10776 Charcoal 1-131 pCi 84.7 80.5 1.05 A
(a) Teledyne Brown Engineering reported result.
(b) The Analytics known value is equal to 100% of the parameter present in the standard as determined by gravimetric and/or volumetric measurements made during standard preparation.
(c) Ratio of Teledyne Brown Engineering to Analytics results.
(d) Analytics evaluation based on TBE internal QC limits: A= Acceptable, reported result falls within ratio limits of 0. 80-1.20. W-Acceptable with warning, reported result falls within 0.70-0.80 or 1.20-1.30. N = Not Acceptable, reported results falls outside the ratio limits of <0.70 and >1.30.
46
Annual Radiological Environmental ODeratino ReDort 2013 Waterford 3 Steam Electric Station Table 8.1 Sample Type: Interlaboratory Comparison Analysis: Gross Beta, Iodine-131, Tritium and Gamma Isotopic Units: pCi/kg (wet)
DOE's MIXED ANALYTE PERFORMANCE EVALUATION PROGRAM (MAPEP)
TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES Month/Year ID Number Matrix Nuclide Units Reported Known Acceptance Evaluation Value (a)
Value (b)
Range (c)
March 2013 13-MaW28 Water H-3 Bq/L 506 507 355 - 659 A
Cs-134 Bq/L 21.0 24.4 17.1 - 31.7 A
Cs-137 Bq/L 0.0446 False positive test A
Co-57 Bq/L 28.3 30.9 21.6 -40.2 A
Co-60 Bq/L 18.2 19.56 13.69 - 25.43 A
Mn-54 Bq/L 25.7 27.4 19.2 - 35.6 A
K-40 Bq/L 2.09 False positive test A
Zn-65 Bq/L 29.2 30.4 21.3 - 39.5 A
13-GrW28 Water Gr-B Bq/L 15.6 13.0 6.5 - 19.5 A
13-MaS28 Soil Cs-134 Bq/kg 859 887 621 - 1153 A
Cs-137 Bq/kg 633 587 411-763 A
Co-57 Bq/kg 0.256 False positive test A
Co-60 Bq/kg 738 691 484 - 898 A
Mn-54 Bq/kg 0.671 False positive test A
K-40 Bq/kg 714 625.3 437.7 - 812.9 A
Zn-65 Bq/kg 1057 995 697-1294 A
13-RdF28 AP Cs-134 Bq/sample 1.73 1.78 1.25 - 2.31 A
Cs-137 Bq/sample 2.73 2.60 1.82 - 3.38 A
Co-57 Bq/sample 2.38 2.36 1.65 - 3.07 A
Co-60 Bq/sample 0.0302 False positive test A
Mn-54 Bq/sample 4.36 4.26 2.98 - 5.54 A
Zn-65 Bq/sample 3.14 3.13 2.19-4.07 A
13-GrF28 AP Gr-B Bq/sample 0.871 0.85 0.43 - 1.28 A
13-RdV28 Vegetation Cs-134 Bq/sample
-0.197 False positive test A
Cs-137 Bq/sample 7.39 6.87 4.81 -8.93 A
Co-57 Bq/sample 9.87 8.68 6.08 - 11.28 A
Co-60 Bq/sample 6.08 5.85 4.10 - 7.61 A
Mn-54 Bq/sample
-0.0104 False positive test A
Zn-65 Bq/sample 6.84 6.25 1 4.38 -8.13 A
47
Annual Radiological Environmental ODeratina Report 2013 Waterford 3 Steam Electric Station Table 8.1 Sample Type: Interlaboratory Comparison Analysis: Gross Beta, Iodine-131, Tritium and Gamma Isotopic Units: pCi/kg (wet)
Month/Year ID Number Matrix Nuclide Units Reported Known Acceptance Evaluation Value (a)
Value (b)
Range (c)
September 2013 13-MaW29 Water H-3 Bq/L 2.45 False positive test A
Cs-134 Bq/L 29.1 30.0 21.0-39.0 A
Cs-137 Bq/L 34.5 31.6 22.1-41.1 A
Co-57 Bq/L 0.0358 False positive test A
Co-60 Bq/L 24.6 23.58 16.51 - 30.65 A
Mn-54 Bq/L 0.0337 False positive test A
K-40 Bq/L 0.193 False positive test A
Zn-65 Bq/L 38.1 34.6 24.2 -45.0 A
13-GrW29 Water Gr-B Bq/L 7.61 5.94 2.97 - 8.91 A
13-MaS29 Soil Cs-134 Bq/kg 1150 1172 820 - 1524 A
Cs-137 Bq/kg 1100 977 684-1270 A
Co-57 Bq/kg 670 False positive test N (2)
Co-60 Bq/kg 502 451 316 - 586 A
Mn-54 Bq/kg 758 674 472 -876 A
K-40 Bq/kg 796 633 443 - 823 W
Zn-65 Bq/kg 210 False positive test N (2) 13-RdF29 AP Cs-134 Bq/sample
-0.570 False positive test N (2)
Cs-137 Bq/sample 2.85 2.7 1.9 - 3.5 A
Co-57 Bq/sample 3.30 3.4 2.4 -4.4 A
Co-60 Bq/sample 2.41 2.3 1.6 - 3.0 A
Mn-54 Bq/sample 3.65 3.5 2.5-4.6 A
Zn-65 Bq/sample 2.90 2.7 1.9 - 3.5 A
13-GrF29 AP Gr-B Bq/sample 1.57 1.63 0.82 - 2.45 A
13-RdV29 Vegetation Cs-134 Bq/sample 5.29 5.20 3.64-6.76 A
Cs-137 Bq/sample 7.48 6.60 4.62 - 8.58 A
Co-57 Bq/sample 0.0129 False positive test A
Co-60 Bq/sample 0.0523 False positive test A
Mn-54 Bq/sample 8.78 7.88 5.52 - 10.24 A
Zn-65 Bq/sample 3.18 2.63 1.84-3.42 W
(1) False positive test.
(2) Soil, Co-57 & Zn-65 identified by gamma software as not detected, MAPEP evaluated as failing the false positive test. A large concentration of Eu-152 was spiked into the sample, causing interference in the analysis. Gamma software recognized the interference and identified them as not detected. MAPEP does not allow clients to enter non-detect designation. NCR 13-04 AP, Cs-134 - MAPEP evaluated the -0.570 as a failed false positive test. No client samples were affected by these failures. NCR 13-04 (a) Teledyne Brown Engineering reported result.
(b) The MAPEP known value is equal to 100% of the parameter present in the standard as determined by gravimetric and/or volumetric measurements made during standard preparation.
(c) DOEIMAPEP evaluation: A=acceptable; W=acceptable with warning; N=not acceptable.
48
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Table 8.1 Sample Type: Interlaborator¥ Comparison Analysis: Gross Beta, Iodine-131, Tritium and Gamma Isotopic Units: pCi/kg (wet)
ERA ENVIRONMENTAL RADIOACTIVITY CROSS CHECK PROGRAM TELEDYNE BROWN ENGINEERING ENVIRONMENTAL SERVICES Month/Year ID Number Matrix Nuclide Units Reported Known Acceptance Evaluation Value (a)
Value (b)
Limits (c)
May 2013 RAD-93 Water H-3 pCi/L 3970 4050 3450 - 4460 A
Ba-133 pCi/L 81.9 82.1 69.0-90.3 A
Cs-134 pCi/L 40.9 42.8 34.2-47.1 A
Cs-137 pCi/L 44.0 41.7 37.0-48.8 A
Co-60 pCi/L 61.9 65.9 59.3 -75.0 A
Zn-65 pCi/L 202 189 170 - 222 A
Gr-B pCi/L 18.0 21.6 13.0-29.7 A
1-131 pCi/L 23.8 23.8 19.7-28.3 A
November 2013 RAD-95 Water H-3 pCi/L 17650 17700 15500-19500 A
Ba-133 pCi/L 57.2 54.2 44.7-59.9 A
Cs-134 pCi/L 83.3 86.7 71.1-95.4 A
Cs-137 pCi/L 201 206 185 - 228 A
Co-60 pCi/L 104 102 91.8 - 114 A
Zn-65 pCi/L 361 333 300 - 389 A
Gr-B pCi/L 30.1 32.2 20.8-39.9 A
1-131 pCi/L 23.1 23.6 19.6-28.0 A
(a)
(b)
(c)
Teledyne Brown Engineering reported result.
The ERA known value is equal to 100% of the parameter present in the standard as determined by gravimetric and/or Volumetric measurements made during standard preparation.
ERA evaluation: A=acceptable. Reported result falls within the Warning Limits. NA=not acceptable. Reported result falls outside of the Control Limit. CE=check for Error. Reported result falls within the Control Limits and outside of the Warning Limits.
49
Annual Radiological Environmental OIeratina ReDort 2013 Waterford 3 Steam Electric Station ATTACHMENT 2 Statistical Comparisons 50
Annual Radiological Environmental Ooerating Reoort 2013 Waterford 3 Steam Electric Station TABLE OF CONTENTS TABLE 2.1 TABLE 2.2 TABLE 2.3 TABLE 2.4 STATISTICAL COMPARISON OF 2013 TLD MEASUREMENTS FROM STATIONS GROUPED BY DISTANCE STATISTICAL COMPARISON OF 2013 TLD RADIATION DOSE TO HISTORICAL DATA BY LOCATION STATISTICAL COMPARISON OF 2013 GROSS BETA ACTIVITY MEASUREMENTS ON AIR PARTICULATE FILTERS STATISTICAL COMPARISON OF 2013 GROSS BETA ACTIVITY MEASUREMENTS IN DRINKING/SURFACE WATER SAMPLES 54 55 56 57 51
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station Statistical Analyses Calculation of the Mean and Standard Deviation The mean and standard deviation for different groups of analyses are calculated using the following equations:
x xi j.=
and 10.5 where:
X = mean of sample population, S = standard deviation of sample population, n = number of samples in sample population, and Xi = value of the i'th sample.
52
Annual Radiological 2013 Environmental Operating Report Waterford 3 Steam Electric Station Comparing Two Sample Population Means The means of two sample populations are compared for statistical difference using the standard "t" test. The use of the test requires the assumption that the data within the populations are normally distributed and that the true standard deviations of the mean are equal for both populations. The standard "t" test tests the hypothesis that the true means of both populations are equal. The "t" value can be calculated from the equation below (obtained from the CRC Standard Mathematical Tables, 26th Edition (1981)):
X-Y nx +n,,-2
)
nx n.,
where:
t
= calculated "t" value, X
= mean of first data set, Y
= mean of second data set, 7, = number of variables in first data set, S, = standard deviation of first data set, q y = number of variables in second data set, and S y = standard deviation of second data set.
The calculated "tr value is used to test the hypothesis that the true mean of the first population (m x) is equal to the true mean of the second population (m y) assuming that the true standard deviation of both populations are equal (m x = m y). The calculated "t" value is compared to a tabular It" value such that:
a if t > t p,n then reject the hypothesis when m, > m Y,
- b.
if t < -t,n then reject the hypothesis when m, < m y,
- c.
if t > t p/2,n then reject the hypothesis when m x = m y, where t p/2,n and t p,n are the tabular "t" values, with a preselected error (5%), confidence level (1 -
p) or (1-p1/2), and degrees of freedom n = nx + ny - 2. Tabular values of the "t" were obtained from the CRC Standard Mathematical Tables, 26th Edition (1981).
53
Annual Radiological Environmental Operatincj Report 2013 Waterford 3 Steam Electric Station TABLE 2.1 STATISTICAL COMPARISON OF 2013 TLD MEASUREMENT§ FROM STATIONS GROUPED BY DISTANCE Stations L t
Stions Located 2-Stations Lopated more than
- Miles from the. Plant-Miles from the Plant 5 Miles from the Plant Mean 12 13 12 (mRem/std.qtr.)
Standard Deviation 1.63 1.20 1.32 (mRemlstd. qtr.)
Number in Sample 62 25 26 Calculated "t" Value 0.89 2.66 NA*
(comparison of stations 0-2 and 2-5 miles from the plant to stations >5 miles from the plant)
Tabular "t" Value at 1.991 (a) 2.012(b)
NA*
95% Confidence(t0.025,n)
(a) Results indicate the mean for stations located 0-2 miles from the plant are statistically identical to the mean for stations located more than 5 miles from the plant.
(b) Although the TLD stations located 2-5 miles from the plant are statistically higher than those located more than 5 miles from the plant, the quarterly doses measured in 2013 are consistent with historical data at each location as shown in Table 2.2.
Not Applicable 54
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station TABLE 2.2 STATISTICAL COMPARISON OF 2013 TLD RA.DIATION DOSE TO HISTORICAL DATA BY LOCATION Units: mrem/Std. Qtr.
Station 1990 - 2012 Avg**
1990 - 2012 Std Dev**
1990 -2012 Range**
.2013 Avg*
2013 Std Dev**
2013 Range**
A-2 13 1.4 10 18 13 0.7 12 14 A-5 13 1.4 10 17 12 1.0 11 13 B-1 13 1.4 10 19 13 0.7 12 14 B-4 13 1.2 11 17 14 0.4 13 14 C-1 9
1.2 7
13 9
0.4 9
10 D-2 12 2.0 8
19 13 0.0 13 13 D-5 12 1.4 9
18 12 0.8 11 13 E-1 11 1.2 9
16 12 0.5 11 12 E-5 12 1.6 9
17 13 0.4 12 13 E-15 11 1.6 8
16 10 0.4 10 11 E-30*
11 1.5 8
17 10 0.4 9
10 F-2 12 1.1 10 17 12 0.4 12 13 F-4 14 1.5 11 19 14 0.4 14 15 F-9 12 1.4 7
17 13 0.5 12 13 G-2 14 1.6 10 19 11 0.5 10 11 G-4 11 1.3 9
16 11 0.4 11 12 G-8 12 1.9 8
19 11 0.4 10 11 H-2 13 1.3 10 18 12 0.0 12 12 H-8 12 1.2 9
17 13 1.0 12 14 J-2 12 1.4 10 17 10 0.4 10 11 J-15 13 1.3 11 17 13 0.7 12 14 K-1 11 1.3 9
16 11 0.4 10 11 L-1 13 1.4 10 16 15 0.9 13 15 M-1 12 1.5 9
18 10 0.4 10 11 N-1 13 1.5 8
18 13 0.5 13 14 P-1 10 1.3 7
15 10 0.5 9
10 P-6 14 1.4 10 19 13 0.4 13 14 Q-1 12 1.2 10 16 13 0.8 12 14 Q-5 13 2.2 9
18 13 0.7 12 14 R-1 10 2.0 6
15 10 0.5 9
10 R-6 12 2.4 8
18 11 0.4 10 11
- Control Location
- Significant outliers were removed from data sets.
PERS data indicates an average of 20 mrem for all indicator locations with a range of 11 to 33 and an average control of 18 mrem.
55
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station TABLE 2.3 STATISTICAL COMPARISO. QF 2013 GROSS BETA ACTIVITY MEASUREMENTS ON AIR PARTICULATE FILTERS SAMPLE STATION
=
APF-i.--
- .APQ-1.
APP-I APC-1I APE-30 Mean 20 19 19 19 20 (10-3pCi/M3)
Standard Deviation 5.04 5.22 5.16 5.08 5.44 (10"3pCi/m3)
Number in Sample 25 25 26 26 26 Calculated "t" Value 0.22 0.62 0.89 0.90 NA*
(comparison of the indicator stations to the control station)
Tabular "t" Value at 2.012(a) 2.012(a) 2.011 (a) 2.011 (a)
NA*
95% Confidence(t0.0 25s,)
I h
i I
(a) Results indicate the mean for the indicator stations is statistically identical to the mean for the control station.
- Not Applicable 56
Annual Radiological Environmental Operating Report 2013 Waterford 3 Steam Electric Station TABLE 2.4 STATISTICAL COMPAR!ON Of, 2013 GROSS BETA ACTIVITY MEASUREMENTS IN:DRINKING/SURFACE WATER SAMPLES DWFiS~
j W EIS 5 DWPISWP-7 Mean 6.2 4.2 4.3 (pCi/liter)
Standard Deviation 0.46 0.52 0.90 (pCi/liter)
Number in Sample 3
4 4
Calculated "t" Value 3.64 0.13 NA*
(comparison of the indicator stations to the control station)
Tabular "t" Value at 2.571(b) 2.447(a)
NA*
95% Confidence(to.025,n)
(a) Results indicate the mean for the indicator station is statistically identical to the mean for the control station.
(b) Results indicate the mean for the indicator station is statistically higher than the mean for the control location. Results obtained in 2013 are consistent with historical data as stated in section 2.3.
- Not Applicable 57