Text
UNITED STATES NUdAR REGULATORY COMMISSION REGIONV 1990 N. CALIFORNIA BOULEVARD 1:
SUITE 202, WALNUT CREEK PLAZA WALNUT CREEK, CALIFORNIA 94596 June 14, 1979 Docket No. 50-206 Southern California Edison Company P. 0. Box 800 2244 Walnut Grove Avenue Rosemead, California 91770 Attention: Mr. J. B. Moore Vice President Gentlemen:
This relates to our letter to you of June 8, 1979, regarding the finding of unacceptable indications in welds in the main feedwater piping system of San Onofre Unit 1 and the discussion (by telephone) of this occurrence between J. L. Crews of this office and E. B. Bresnahan of your staff on June 14, 1979.
Based upon information presented by your staff in a meeting with the NRC staff in Bethesda, Maryland on June 13, 1979, we concur in the appropriateness of the corrective measures taken or to be taken by you, including repairs to remove the unacceptable indications in the welds.
As a result of discussions with Mr. Bresnahan on June 14, 1979, it is our understanding that you will take the following additional actions.
- 1. Conduct baseline inservice examinations of the weld repairs made to the main feedwater piping system, following any required stress re lieving process and prior to a resumption of power operation.
These welds will be re-examined no later than the next refueling shutdown.
- 2. Submit an interim written report to the NRC, with a copy provided to our Resident Inspector (Mr. R. J. Pate) prior to resuming power operation of the San Onofre Unit 1. This report will include the information presented to the NRC staff in the meeting of June 13, 1979, regarding the results of your evaluation of the cause(s) of the weld defects and corrective actions taken or to be taken.
7907120 3G5
e 9
Southern California Edison Company June 14, 1979
- 3.
Submit within 45 days from the date of this letter a final written report of this occurrence, including the results of additional metallurgical analyses of the weld defects and a stress analysis of the feedwater piping system of San Onofre Unit 1.
Should our understanding as stated above not be correct, you should notify this office promptly in writting.
Sincerely, R. H. Engelken Director cc: J. T. Head, SCE J. M. Curran, SCE (San Clemente)
05 UNITED STATES 7
NUCLEAR REGULATORY COMMISSION o
E WASHINGTON, D. C. 20555 June 11, 1979 ALL POWER REACTOR LICENSEES Gentlemen:
Enclosed for your information is a copy of NUREG-0560 "Staff Report on the Generic Assessment of Feedwater Transients in Pressurized Water Reactors Designed by the Babcock & Wilcox Company".
Sincerely, Brian K. Grimes, Assistant Director for Engineering and Projects Division of Operating Reactors
Enclosure:
NUREG-0560 cc w/enclosure:
Service Lists for B&W Power Reactor Licensees cc w/o enclosure:
All Other Service Lists FOR THE PECrRD:
SAs of,2 1EA Corp., has not placed this docunent in the DocTment Control System and has not returned the second "Docket File" copy.
Consequently, this "only copy" is being filed without an accession number and under the docket number for the first unit.
THE FILES
Mr. James H. Drake cc Charles R. Kocher, Assistant General Counsel Southern California Edison Company Post Office Box 800 Rosemead, California 91770 David R. Pigott Samuel B. Casey Chickering & Gregory Three Embarcadero Center Twenty-Third Floor San Francisco, California 94111 Jack E. Thomas Harry B. Stoehr San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 U. S. Nuclear Regulatory Commission ATTN:
Robert J. Pate P. 0. Box 4167 San Clemente, California 92672 Mission Viejo Branch Library 24851 Chrisanta Drive Mission Viejo, California 92676