ML13331A293

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Re Util Responses to NRC Bulletin 88-002, Rapidly Propagating Fatigue Cracks in Steam Generator Tubes. Responses Acceptable Subj to Development of Controls to Steam Generators.Proprietary Rept Withheld
ML13331A293
Person / Time
Site: San Onofre 
Issue date: 01/06/1989
From: Trammell C
Office of Nuclear Reactor Regulation
To: Baskin K
SOUTHERN CALIFORNIA EDISON CO.
Shared Package
ML13331A294 List:
References
IEB-88-002, IEB-88-2, TAC-67322, NUDOCS 8901110363
Download: ML13331A293 (2)


Text

January 6, 1989 Docket No.:

50-206 DISTRIBUTION Docket File NRC & LPDRs CTrammell (2)

Mr. Kenneth P. Baskin MVirgilio Vice President 3Lee Southern California Edison Company OGC-White Flint 2244 Walnut Grove Avenue PD5 Plant File Post Office Box 800 EJordan Rosemead, California 91770 BGrimes ACRS (10)

E. Murphy

Dear Mr. Baskin:

SUBJECT:

CLOSEOUT OF NRC BULLETIN 88-02, "RAPIDLY PROPAGATING FATIGUE CRACKS IN STEAM GENERATOR TUBES" (TAC NO. 67322)

Re:

San Onofre Nuclear Generating Station, Unit No. 1 The NRC staff has completed its review of your responses to NRC Bulletin 88-02, "Rapidly Propagating Fatigue Cracks in Steam Generator Tubes." As discussed in detail in the enclosed Safety Evaluation, we find your responses acceptable.

This finding is subject to your developing administrative controls to ensure that updated calculations are performed for any significant changes to the steam generators relative to the reference parameters of this analysis.

Sincerely, Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects

Enclosures:

1. Safety Evaluation with Attachment 1 (Proprietary) (licensee only)
2. Safety Evaluation with Attachment 2 (Non-proprietary) cc w/enclosure:

See next page D5 DRSP/D:PD5 Tmmell:

GKnighton

/ /89

\\ /(9/80 OFFICIAL RECORD COPY pITjR A 0K PDC2~,~e

Mr. Kenneth P. Baskin San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc Charles R. Kocher, Assistant Mr. Jack McGurk, Acting Chief General Counsel Radiological Health Branch James Beoletto, Esquire State Department of Health Southern California Edison Company Services Post Office Box 800 714 P Street, Office Bldg. 8 Rosemead, California 91770 Sacramento, California 95814 David R. Pigott Mr. Hans Kaspar, Executive Director Orrick, Herrington & Sutcliffe Marine Review Committee, Inc.

600 Montgomery Street 531 Encinitas Boulevard, Suite 105 San Francisco, California 94111 Encinitas, California 92024 Mr. Robert G. Lacy Manager, Nuclear San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/Sari Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego 1600 Pacific Highway Room 335 San Diego, California 92101 Director Energy Facilities Siting Division Energy Resources Conservation &

Development Commission 1516 - 9th Street Sacramento, California 95814 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596