June 6, 1988 Docket No. 50-206 DI-STRIBUTION-----

Docket-File NRC & LPDRs CTrammell Mr. Kenneth P. Baskin GHolahan Vice President JLee Southern California Edison Company.

OGC-White Flint 2244 Walnut Grove Avenue PDV Plant File Post Office Box 800 EJordan Rosemead, California 91770 JPartlow ACRS (10)

Dear Mr. Baskin:

RHuey AHon RZimmerman

SUBJECT:

CONTAINMENT LEAK RATE TESTING.(TAC NO.

68170)

Re:

San Onofre NucleaR Generating Station, Unit No. 1 This is in response to your letter.of May 4, 1988, regarding containment leak rate testing, in which you suggest that a change to the language of Technical Specification 4.3.1 might improve its.clarity.

We have discussed this matter with both the NRC resident inspectors and your staff and conclude that the specification, as written, is adequately clear.

We have reviewed your May 4 letter and agree with the explanation contained therein.

Although we agree that.the specification could be worded differently, we believe the added effort on both our parts to amend it is not warranted, especially in light of our aigreement and exchange.of letters on the subject..

As discussed with your staff, we request thatyou defer any proposed change.on this point until such time in the future as other changes.to this specification may be needed.

No response to this letter is requested unless you disagree with this ap roach.

Sincerely, ORIGINAL SIGNED BY CharlesvM. Trammell, Project Manager Project Directorate V Division of Reactor Projects

III, IV, V and Special Projects See next page.

QPrD5 PD5 CTrammell:dr hton 06/P.

88 06

/88 OFFICIAL RECORD COPY 8806210403 880606 PDR ADOCK 05000206 P

_PDR_

June 6, 1988 Docket No. 50-206 DISTRIBUTION Docket File NRC & LPDRs CTrammell Mr. Kenneth P. Baskin GHolahan Vice President JLee Southern California Edison Company OGC-White Flint 2244 Walnut Grove Avenue PDV Plant File Post Office Box 800 EJordan Rosemead, California 91770 JPartlow ACRS (10)

Dear Mr. Baskin:

RHuey AHon RZimmerman

SUBJECT:

CONTAINMENT LEAK RATE TESTING (TAC NO.

68170)

Re:

San Onofre NucleaR Generating Station, Unit No. 1 This is in response to your letter of May 4, 1988, regarding containment leak rate testing, in which you suggest that a change to the language of Technical Specification 4.3.1 might improve its clarity.

We have discussed this matter with both the NRC resident inspectors and your staff and conclude that the specification, as written, is adequately clear.

We have reviewed your May 4 letter and agree with the explanation contained therein.

Although we agree that the specification could be worded differently, we believe the added effort on both our parts to amend it is not warranted, especially in light of our agreement and exchange of letters on the subject.

As discussed with your staff, we request that you defer any proposed change on this point until such time in the future as other changes to this specification may be needed.

No response to this letter is requested unless you disagree with this approach.

Sincerely, ORIGINAL SIGNED BY Charles M. Trammell, Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects See next page QPD5
PDS CTrammell:dr

£ hton 06/P188 06

/88 OFFICIAL RECORD COPY

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 June 6, 1988 Docket No. 50-206 Mr. Kenneth P. Baskin Vice President Southern California Edison Company 2244 Walnut Grove Avenue Post Office Box 800 Rosemead, California 91770

Dear Mr. Baskin:

SUBJECT:

CONTAINMENT LEAK RATE TESTING (TAC NO. 68170)

Re:

San Onofre Nuclear Generating Station, Unit No. 1 This is in response to your letter of May 4, 1988, regarding containment leak rate testing, in which you suggest that a change to the language of Technical Specification 4.3.1 might improve its clarity.

We have discussed this matter with both the NRC resident inspectors and your staff and conclude that the specification, as written, is adequately clear.

We have reviewed your May 4 letter and agree with the explanation contained therein.

Although we agree that the specification could be worded differently, we believe the added effort on both our parts to amend it is not warranted, especially in light of our agreement and exchange of letters on the subject.

As discussed with your staff, we request that you defer any proposed change on this point until such time in the future as other changes to this specification may be needed.

No response to this letter is requested unless you disagree with this approach.

Sincerely, Charles M. Trammell, Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects See next page

Mr. Kenneth P. Baskin San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc Charles R. Kocher, Assistant Mr. Jack McGurk, Acting Chief General Counsel Radiological Health Branch James Beoletto, Esquire State Department of Health Southern California Edison Company Services Post Office Box 800 714 P Street, Office Bldg. 8 Rosemead, California 91770 Sacramento, California 95814 David R. Pigott Mr. Hans Kaspar, Executive Director Orrick, Herrington & Sutcliffe Marine Review Committee, Inc.

600 Montgomery Street 531 Encinitas Boulevard, Suite 105 San Francisco, California 94111 Encinitas, California 92024 Mr. Robert G. Lacy Mr. Dennis M. Smith, Chief Manager, Nuclear Radiological Programs Division San Diego Gas & Electric Company Governor's Office of Emergency Svcs.

P. 0. Box 1831 State of California San Diego, California 92112 2800 Meadowview Road Sacramento, California 95832 Resident Inspector/San Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diege San Diego, California 92101 Director Energy Facilities Siting Division Energy Resources Conservation &

Development Commission 1516 - 9th Street Sacramento, California 95814 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596