DEC 0 3 Docket No.:
50-206 Mr. Kenneth P. Baskin, Vice President Nuclear Engineering Safety and Licensing Department Southern California Edison Company 2244 Walnut Grove Avenue P.O. Box 800 Rosemead, California 91770
Dear Mr. Baskin:
SUBJECT:
TRANSMITTAL OF IN-PROGRESS AUDIT REPORT ON DETAILED CONTROL ROOM DESIGN REVIEW (DCRDR)
Re:
San Onofre Nuclear Generating Station, Unit 1 (SONGS-1)
Enclosed is the report prepared by our consultants regarding the July 15-18, 1986 audit of your DCRDR activities. The NRC staff has reviewed and is in agreement with the findings and conclusions contained in the report. These findings are being transmitted to you for use in completing your DCRDR.
i Overall, it appears that you have developed a Program Plan that should guide the DCRDR to a successful conclusion. The additional information that we request, as detailed in the audit report, should be provided in your DCRDR Summary Report, now scheduled to be submitted on May 1, 1987, as should any revisions or changes to the process and procedures described in the Program Plan. Additionally, the Summary Report should include descriptions of human engineering discrepancies (HEDs), justification for not or only partially correcting HEDs, and the schedule for implementing corrective actions. If all of these issues are resolved and so documented in the Summary Report, the DCRDR at SONGS-1 should be successful.
The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.
7S Richard F. Dudley, Project Manager Project Directorate #1 Division of PWR Licensing-A
Enclosure:
As Stated I r -- a i7f oo59 861203 cc's:
See Next Page PDR ADOCK 0500020 I
P PDR
- SEE PREVIOUS CONCURRENCE Office:
LA/PAD#1 /,,,
PM/PAD#1 PD/PAD#1 Surname:
PShuttleworth RDudley/tg GLear Date:
1/3 /86 11/29/86 1-1
/86
Mr. Kenneth P. Baskin San Onofre Nuclear Generatino Southern California Edison Company Station, Unit No. 1 cc Charles R. Kocher, Assistant Joseph 0. Ward, Chief General Counsel Radiological Health Branch James Beoletto, Esquire State Department of Health Southern California Edison Company Services Post Office Box 800 714 P Street, Office bldg. 8 Rosemead, California 91770 Sacramento, California 95814 David R. Pigott Mir. Hans Kaspar, Executive Director Orrick, Herrington & Sutcliffe Marine Review Committee, Inc.
600 Montgomery Street 531 Encinitas Boulevard, Suite 105 San Francisco, California 94111 Encinitas, California 92024 Mr. Stephen B. Allman Ann C. Vasques, Chief San Diego Gas & Electric Company Radiological Programs Division P. 0. Box 1831 Governor's Office of Emergency Svcs.
San Diego, California 92112 State of California 2800 Meadoviview Road Sacramento, CA 95832 Resident Inspector/San Onofre NPS c/o U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego San Diego, California 92101 Director Energy Facilities Siting Division Energy Resources Conservation &
Development Commission 1516 - 9th Street Sacramento, California 95814 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane Walnut Creek,' California 94596