March 13, 1981 Docket No. 50-206 LS05-81-03-023 Mr. R. Dietch, Vice President Nuclear Engineering and Operations Southern California Edison Company 2244 WalnutGrove.Avenue Post Office Box 800 Rosemead, California 91770

Dear Mr. Dietch:

SUBJECT:

SEP TOPICS VI-7.C, ECCS SINGLE FAILURE CRITERION AND REQUIREMENTS FOR LOCKING OUT POWER TO VALVES AND VI-7.C.2, FAILURE MODE ANALYSIS (SAN ONOFRE)

The staff, as part of our review of the subject topics, has noted the content of Amendment No. 25 to Provisional Operating License DPR-13 issued April 1, 1977. Based on the assumption that you have complied with our request in our October 16, 1978 letter to install redundant undervoltage relays on each of the 4160 busses 1C and 2C during the refueling outage for Cycle 7 operation, we have concluded that the subject topics duplicate our previous submittal and our review thereof.

Please inform us within 30 days if this assumption is correct so that the subject topics may be considered completed with the exception of consideration of implementation of the other three permanent modifications previously deferred and publication of the integrated assessment for your plant.

Sincerely, Dennis M. Crutchfield, Chief Operating Reactors Branch No. 5 Division of Licensing cc:

See next page SEP :DL EM1<'KLh 3//f'/81 bA OFFICESEPB:D EPB:DL:SL

DL:C L:PM OR A

ADL SURNAMEO SGagnon:dk CBerlinger WRussell S

ki DCr field nas DATE

()/81 3//D/81 3/ t /81 3

81 3/l /81 3/ /81 NRC FORM 318 110/8 )NRCM 0240

.OFFICIAL RECORD COPY USGPO: 1980-329-824

j,;Ft EGU V

+0 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 March 13, 1981 Docket No. 50-206 LS05-81-03-023 Mr. R. Dietch, Vice Presidint, Nuclear Engineering and Operations Southern California Edison Company 2244 Walnut Grove Avenue Post Office Box 800 Rosemead, California 91 70

Dear Mr. Dietch:

SUBJECT:

SEP TOPICS VI-7.C, ECCS SINGLE FAILURE CRITERION AND REQUIREMENTS FOR LOCKING OUT POWER TO VALVES AND VI-7.C.2, FAILURE MODE ANALYSIS (SAN ONOFRE)

The staff, as part of our review of the subject topics, has noted the content of Amendment No. 25 to Provisional Operating License DPR-13 issued April 1, 1977. Based on the assumption that you have complied with our request in our October 16, 1978 letter to install redundant undervoltage relays on each of the 4160 busses IC and 2C during the refueling outage for Cycle 7 operation, we have concluded that the subject topics duplicatejour previous submittal and our review thereof.

Please inform us within 30 days if this assumption is correct so that the subject topics may be considered completed with the exception of consideration of implementation of the other three permanent modifications previously deferred and publication of the integrated assessment for your plant.

Sincerely, lslM.ICrutchield, oief Operating Reactors Branch No. 5 Division of Licensing cc:

See next page

1 g

Mr. R. Dietch 2 -

March 13, 1981 cc Charles R. Kocher, Assistant Director, Criteria and Standards General Counsel Division Southern California Edison Company Office of Radiation Programs Post Office Box 800 (ANR-460)

Rosemead, California 9.1770 U. S. Environmental Protection Agency David R. Pigott Washington, D. C.

20460 Samuel B. Casey Chickering & Gregory U. S. Environmental Protection Three Embarcadero Center Agency Twenty-Third Floor Region IX Office San Francisco, California 94111 ATTN:

EIS COORDINATOR 215 Freemont Street Jack E. Thomas San Francisco, California 94111 Harry B. Stoehr San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/San Onofre NPS c/o U. S. NRC P. 0. Box 4329 San Clemente, California 92672 Mission Viejo Branch Library 24851 Chrisanta Drive Mission Viejo, California 92676 Mayor City of San Clemente San Clemente, California 92672 Chai rman Board of Supervisors County of San Diego San Diego, California 92101 California Department of Health ATTN:

Chief, Environmental Radiation Control Unit Radiological Health Section 714 P Street, Room 498 Sacramento, California 95814

EGa s

oUNITED STATES o "NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 March 13, 1981 Docket No. 50-206 LS05-81-03-023 Mr. R. Dietch, Vice President Nuclear Engineering and Operations Southern California Edison Company 2244 Walnut Grove Avenue Post Office Box 800 Rosemead, California 91770

Dear Mr. Dietch:

SUBJECT:

SEP TOPICS VI-7.C, ECCS SINGLE FAILURE CRITERION AND REQUIREMENTS FOR LOCKING OUT POWER TO VALVES AND VI-7.C.2, FAILURE MODE ANALYSIS (SAN ONOFRE)

The staff, as part of our review of the subject topics, has noted the content of Amendment No. 25 to Provisional Operating License DPR-13 issued April 1, 1977.1 Based on the assumption that you have complied with our request in our October 16, 1978 letter to install redundant undervoltage relays on each of the 4160 busses 1C and 2C during the refueling outage for Cycle 7 operation, we have concluded that the subject topics duplicate jour previous submittal and our review thereof.

Please inform us within 30 days if this assumption is correct so that the subject topics may be considered completed with the exception of consideration of implementation of the other three permanent modifications previously deferred and publication of the integrated assessment for your plant.

Sincerely, sM.Crutchied if Operating Reactors Branch No. 5 Division of Licensing cc:

See next page 84 1S0

Mr. March 13, 1981 cc:

Charles R. Kocher, Assistant Director, Criteria and Standards General Counsel Division Southern California Edison Company Office of Radiation Programs Post Office Box 800 (ANR-460)

Rosemead, California 91770 U. S. Environmental Protection Agency David R. Pigott Washington, D. C. 20460 Samuel B. Casey Chickering & Gregory U. S. Environmental Protection Three Embarcadero Center Agency Twenty-Third Floor Region IX Office San Francisco, California 94111 ATTN: EIS COORDINATOR 215 Freemont Street Jack E. Thomas San Francisco, California 94111 Harry B. Stoehr San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/San Onofre NPS c/o U. S. NRC P. 0. Box 4329 San Clemente, California 92672 Mission Viejo Branch Library 24851 Chrisanta Drive Mission Viejo, California 92676 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego San Diego, California 92101 California Department of Health ATTN: Chief, Environmental Radiation Control Unit Radiological Health Section 714 P Street, Room 498 Sacramento, California 95814