Forwards Safety Evaluation & Consultant Rept Supporting Precautions Taken to Minimize Occurrence of Steam Generator Water Hammer in Feedwater Piping.Ack Commitment to Further Evaluate Water Hammers
ML13330A043
Person / Time
Site: San Onofre 
Issue date: 04/22/1980
From: Ziemann D
Office of Nuclear Reactor Regulation
To: Dietch R
SOUTHERN CALIFORNIA EDISON CO.
Shared Package
ML13330A044 List:
References
TASK-05-13, TASK-5-13, TASK-RR NUDOCS 8005120114
Download: ML13330A043 (2)


Text

80 0512 o //

DISTRIBUTION

'Rsu mr'l V"R CP Docket iRC PDR Local PDR ORB Reading APR 2 9NRR Reading Docket No. 50-206 2 198 V. Stello DEisenhut BGrimes Dr. Mr. R. Dietch RVollmer Vice President TJCarter Nuclear Engineering and Operations DLZiemann Southern California Edison Company ABurger 2244 Walnut Grove Avenue A~urger Post Office Box 8800 HSmith Rosemead, California 91770 OI&E (3)

OELD

Dear Mr. Dietch:

NSIC TERA RE: STEAM GENERATOR WATER HAMMER ISSUE ACRS (16)

We have completed our review of your submittals relating to the potential for water hammer in the San Onofre, Unit 1 feedwater piping. Based on this review we have concluded that acceptable precautions are being taken to minimize the occurrence of steam generator water hammer in the feedwater piping.

As on additional prudent measure you will conduct a program to evaluate further the potential-magnitude of water hammers, define their effects on components of the feedwater system and identify appropriate corrective actions. We acknowledge your commitment to complete this program by September, 1980 and to submit the results for our review.

Our Safety Evaluation and our Consultant's report are enclosed.

Sincerely, Original sioned by Dennis L. Ziemann, Chief Operating Reactors Branch #2 Division of Operating REactors

Enclosures:

1. Safety Evaluation
2. Consultant's report

~~~....OR.

FFICE R..

2.. OR.. ORB SURNAME

.ABr.

.an NfCFaRM 318 (9r76) NRCM 0240

  • .U.S.

GOVERNMENT PRINTING OFFICE: 1979-289-369

..fetch.

April 22, 1980 cc.

Cha

. Kccher, Assi stt Di -ctor, Tec acal Assessment General Counse Divi sion Southern California Edison Comany Office of Radiation Programs, PCst Office Sox V00 (AW-459)

Rosemead, California 91770 U. S. Environmental Protection Agency David R. Pigaott Crystal Mall #2 SSamuel B. Casey Arlington, Virginia 20460 Chickering & Gregory Three. Embarcadero Center U. S. Environmental Protection Twenty-Third Floor Agency San Francisco, California 94111 Region IX Office ATTN:

EIS COORDINATOR Jack E. Thomas 215 Freemont Street Harry B. Stoehr San Francisco, California 94111 San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector c/o U. S. NRC P. 0. Box AA Oceanside, California 9254 Mission Viejo.Branch Library 24851 Chrisanta Drive Mission Viejo, California 92676 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego San Diego, California 92101 California Department of.ealth ATT:N:

Chief, Environmental Radiation Control Unit Rad olocical Health Section 714 P Street, Room 498 Sacramento, California 95814