Enclosure 1 ANNUAL OPERATING REPORT OF SAN ONOFRE NUCLEAR GENERATING STATION UNIT 1 FOR 1980 MAINTENANCE, DESIGN CHANGES, AND RADIOLOGICAL ENVIRONMENTAL MONITORING SOUTHERN CALIFORNIA EDISON COMPANY SAN DIEGO GAS AND ELECTRIC COMPANY DOCKET NO. 50-206 LICENSE NO. DPR-13 REGULATORY OCK RLE COPY 1.040765 55

SAN ONOFRE NUCLEAR ERATING STATION -

UNIT 1 CORRECTIVE MAINTENANCE OF COMPONENTS DESIGNED TO MINIMIZE THE RELEASE OF TOXIC OR RADIOACTIVE MATERIALS TO THE ENVIRONMFNT Docket No. 50-206 San Diego County, California Reporting Period January - December, 1980 MALFUNCTION EFFECT ON PRECAUTION TAKEN TO PROVIDE COMPONENT CAUSE EFFECT PLANT OPERATION CORRECTIVE ACTION FOR ENVIRONMENT'S PROTECTION North Waste Motor Compressor None Replaced Motor Alternate Processing Gas Compressor Burned Up Inoperative North Waste Faulty No Discharge None Overhaul Compres-Alternate Processing Gas Compressor Valves and Pressure sor Motor Replace Motor 3 Air Samplers Misc.

Samplers None Overhaul Spare Air Samplers Used Malfunctions -Inoperative Air Samplers Radwaste Discharge Filter Low Flow None Replace Filter None Required Filter Plugged Elements ORMS Detector Contaminated High None Decontaminate None Required 1218

Background

Detector

SAN ONOFRE NUCLEAR GENERATING STATION DESIGN CHANGES APPROVED DURING THE YEAR 1980 The following design changes were approved for implementation by the On-Site Review Committee in 1980.

Except as noted, the design changes were fully implemented as of the end of the calendar year 1980. This list ful fills the.reporting requirements of Section 5.6.1b of the Environmental Technical Sp~cifications. With respect to this requirement, none.of the 1980 changes resulted in a condition which significantly altered the impact of the Station on the environment as described in the NRC Final Environmental State ment and did not involve a change in the Environmental Technical Specifications incorporated in the San Onofre Unit 1 Provisional Operating License DPR-13.

1. DESIGN CHANGE 80-02: MODIFICATION TO VENT VALVE ACTUATORS TO LIMIT OPENING TO 500 This plant modification will provide stops to limit the opening of vent valves CV-10 and CV-116 to 500 from the fully closed position as required by the NRC letter of October 23, 1979. This modification was committed to for the January outage in SCE letter of January 15, 1980, to D. L.

Ziemann of the NRC from K. P. Baskin.

(See Page 3 of letter.)

The reason for this change is to satisfy NRC requirements as stated in NRC letter of October 23, 1979, to "limit the valves to be no more than 300 to 500 open."

2. DESIGN CHANGE 80-04: THE'INSTALLATION OF CONTAINMENT HYDROGEN RECOMBINERS.

(TMI)

(IN PROGRESS)

This plant modification consists of the addition of necessary supports.

for redundantsafety related quality class hydrogen recombiners inside the containment sphere to deal with the long-term post LOCA generation of hydrogen.

The recombiners scheduled to be installed during a projected January 1981 outage will be mounted on steel platforms extended from the A&C steam generator enclosure structures at elevation 53'-6". Access ladders will be provided from the operation deck (el. 42'-0") to the platform for required normal maintenance.

DESIGN CHANGES, 1980

3. DESIGN CHANGE 80-07: ADDITION OF MECHANICAL PENETRATIONS (In Progress)

This plant modification consists of the addition of containment pene trations only, for sampling lines for obtaining samples of the reactor coolant and of the containment atmosphere. The sampling lines and asso ciated systems will be incorporated by a future design change to be pre pared later in 1981.

4. DESIGN CHANGE 80-28: (Revision 2):

POST-ACCIDENT SAMPLING STATION (In Progress)

The purpose of this design change is to provide a shielded underground sample station which will be constructed to house the Post-Accident Sample System. The underground arrangement will minimize personnel expos'ure and preserve space for normal station activities.

5. DESIGN CHANGE 80-30:

INCREASED RANGE OF NOBLE GAS EFFLUENT RADIATION MONITOR (In Progress)

This design change consists of an extended range plant stack effluent radiation monitor that will be capable of measuring post-accident noble gas activity, as Xe-133, from concentrations of ALARA (1 x 10-7 pCi/cc) to 1 x 105 PCi/cc. The system will also provide grab samples for deter mining the 1-131 release.

6. DESIGN CHANGE 80-31:

STEAM DUMP AND SAFETY VALVE HEADER RADIATION MONITORS (In Progress)

This design change adds a radiation monitoring system for the two atmos pheric steam dump valve and steam safety valve headers. The monitors will be installed at the headers'to indirectly monitor the noble gas level by measuring the radiation level of the contained steam to 104 rads per hour with an accuracy of +/- 20 percent. Readout will be provided in the main Control Room and in the Technical Support Center.

0)

DESIGN CHANGES, 1980

7. DESIGN CHANGE 80-32:

ONSITE TECHNICAL SUPPORT CENTER (TMI) (In Progress)

This plant modification consists of the addition of an Onsite Technical Support Center (TSC) located adjacent to the main Control Room in the existing visitors viewing area and a mechanical equipment room on the southeast corner of the administration and control building. The TSC will contain equipment capable of monitoring plant critical functions, and files containing current plant drawings and documents..Operations data will be stored in a moving head disc system.

8. DESIGN CHANGE 80-33: CONTAINMENT PRESSURE INDICATION (In Progress)

Provided by this design change will be new, separate, and redundant containment pressure indicators. The new transducers will tap from the same line as the existing pressure transducers.

Each system will consist of the following components:

Pressure transmitter Signal converter (I/V)

Control Room panel indicating instrument Instrument tubing and valves

9. DESIGN CHANGE 80-36:

REACTOR COOLANT SYSTEM VENTING (In Progress)

This design change consists of a remotely operated system for venting the reactor coolant system during post-accident situations when large quantities of non-condensable gases may collect in reactor coolant system high points. The venting system will utilize existing maintenance vent line stubs.

10. DESIGN CHANGE 80-44: METEOROLOGICAL TOWER MODIFICATIONS (In Progress)

This modification consists of moving the majority of the signal condition ing and recording equipment associated with the meteorological monitoring system from its present location in a room adjacent to the SONGS 1 Control Room to a climate-controlled instrument shelter to be located near the Bluff Meteorological Tower.

DESIGN CHANGES, 1980

11.

DESIGN CHANGE 80-52:

FUEL OIL TRANSFER PUMP DRAINAGE (In Progress)

This design change provides a drainage system (see Figure 1) for the fuel oil transfer pump vaults adequate for the removal of water resulting from any storm, up to and including the PMF, sufficiently rapid to limit the maximum depth of water in the vault to below the fuel oil transfer pump motor coupling. Check valves will be provided in the drain lines to prevent backflow. Curbing at grade will be improved to prevent flood runoff from entering the vaults.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January -

December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

-. Name Location Low Mean High Units AIR SAMPLING Weekly 5

(1)*

1311-257 0

(All sanples were below dete tion limi s) pCi/m3 5 (1)

Gross Beta-0 Visitor 0.1mi. 150mag.

0.006 0.049 0.204 pCi/m3 257 Center Quarterly Composite 5 (1)

Gross Alpha-0 Huntington 37mi. 3000mag.

0.0006 0.0020 0.0036 pCi/m3 20 Beach 5 (1) 137Cs-20 0

.(All samples were b low detec ion limi s) pCi/m3 5 (1) 90Sr-20 0

San Clemente 5.Omi. 3200mag 0 0.0001 0.0002 pCi/m 3 5 (1) 7Be-20 0

Huntington 37mi. 300 0mag.

0.06 0.08 0.14 pCi/m3 Beach 4

(1) 141Ce-4 0

San Clemente 5.Omi. 320 0mag 0.006 pCi/m3 5 (1) 95Zr-5 0

San Clemente 5.Omi. 320 0mag 0.011 pCi/m3 5

(1) 95Nb-5 0

San Clemente 5.Omi. 3200 mag 0.014 pCi/m3

  • N mber in ( ) indicates num er of location sampled in addition to E.T.-. specified locations

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January - December. 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations I__________

Sampling Total No. of Above Local Medium Locations Samples

Background

_Name Location Low Mean High Units DIRECT RADIATION Quarterly 16 (2)*

Accumulated 0

Huntington 37mi. 300 0mag.

25.1 31.1 38.2 mR/Qtr.

Dose - 48 Beach Annual 16 (2) Accumulated 0

Huntington 37mi. 300 0mag.

61.0 76.0 92.0 mR/Year Dose -

16 Beach

  • Nunber in ( ) indicates num er of locations sampled in addition to E.T.!. specified locations

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE-NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January -

December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

Name Location Low Mean High Units DRINKING WATER FILTRATI Monthly 3

Gross Alpha-(All samples were below cetection limits) pCi/2.

35 3

Gross Beta-35 Tri-Cities 8.7mi. 320amag.

7 11.8 19 pCi/yt Water Dist.

Quarterly Composite 3

Gross Alpha-0 Tri-Cities 8.7mi. 3200mag.

1 3

pCi/Z 12 Water Dist.

3 Gross Beta-12 0

Tri-Cities 8.7mi. 3200 mag.

9 13 16 pCi/k Water Dist.

3 3H-12 0

Tn-Cities 8.7mi. 3200mag.

0 150 600 pCift Water Dist.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January -

December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

Name Location Low Mean High Units DRINKING WATEZ SOLIDS Monthly 3

Gross Alpha-Huntington 37mi.

30(' mag.

0.05 0.6 pCi/i 35 Beach 3

Gross Beta-35 0

Tri-Cities 8.7mi. 320 0mag.

0.8 1.5 2.7 pCi/.

Water Dist.

Quarterly 3

Gross Alpha-0 Huntington 37mi. 300 0mag.

0 0.1 0.4 pCi/i Composite 12 Beach 3

Gross Beta-12 0

San Clemente 3.5mi. 320amag 0.9 1.7 2.3 pCi/

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January - December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

Name Location Low Mean High Units OCEAN WATER BiMonthly 4

(2)*

Gross Beta-24 0

SONGS I-O.5mi.

215 0mag.

670 903 1340 pCi/l Outfall 4 (2)

GIS i)Scan Cs-24 1

SONGS I-0.5mi. 215 0mag. 0 72 430 pCi/y Outfall Semi-Annual Composite 4 (2) 3H-8 2

SONGS I-0.5mi. 215 0mag.

950 pCi/

Outfall

  • Nunber in ( ) indicates number of locations sampled in addition to E.T.S specified ocations

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January -

December. 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

Name Location Low Mean High Units BEACH SAND 4

137Cs-8 2

Surfing 1.4mi. 305 0mag.

O 0.06 0.12 pCi/g-Dr Beach Wt 4

.226Ra-8 0

0.5mi.South 0.5mi. 125 0mag.

0.22 0.46 0.70 pCi/g-Dr Decay Chain of Unit 1 Wt 4

232Th-8 0

Surfing 1.4mi. 305 0mag.

0.26 0.43 0.60 pCi/g-Dr Decay Chain Beach Wt LOCAL CROPS Ge(Li)Scan 2

131 0

(All sanples were below detection limits) 1-2 nCi/Kg 2

137Cs-2 (All sanples were below detection limits) nCi/Kg Radiochemical 2

90r-2 0

(All sanples were below detection limits)

S-2 nCi/Kg 2

3H-2 0

Oceanside 23mi. 135 0mag.

110 205 300 nCi/Kg

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January -

December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

Name Location Low Mean High Units NON-MIGRATORY DrjeWt.

MARINE ANIMAL3 Ge(Li)Scan 3 (1) 137Cs-48 0

SONGS II & O.7mi.

215 0mag.

0 0.02 0.06 nCi/Kg II&

3 (1) 58Co-48 2

SONGS II & -0.7mi. 215 0mag.

0 0.10 0.54 nCi/Kg III 3 (1) 60Co-..48 2

SONGS II & 0.7mi. 215 0mag.

0 0.11 0.91 nCi/Kg III 3 (1) 1lOmAg-48 2

SONGS I 0.bmi. 215 0mag.

0.169 1.3 nCi/Kg Radiochemi-cal 3 (1) 3H-48 SONGS I 0.6mi. 215 0mag.

0 113 450 nCi/Kg 3 (1) 90Sr-45 1

SONGS II & 0.7mi. 2150mag.

O 0.004 0.07 nCi/Kg III

  • Ntmber in ( ) indicates numter of locations sampled in addition to E.T.S. specified locations

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January - December, 1980

  1. of
  1. of Locations ISAMPLING LOCATION WITH HIGHEST MEAN Sampling Total No. of Above Local Medium Locations Samples

Background

Name Location Low Mean High Units NON-MIGRATORY MARINE ANIMAL:

Ge(Li)Scan Wet Wt.

3 (1)*

137Cs-48 0

Newport 30mi. 305 0mag.

0 0.006 0.015 nCi/Kg Beach 3 (1) 58Co-48 2

SONGS II & 0.7mi. 2150 mag.

0 0.022 0.101 nCi/Kg III 3 (1) 60Co-48 2

SONGS I 0.6mi. 2150 mag.

0 0.045 0.266 nCi/Kg 3 (1) 110mAg-48 2

SONGS II & 0.7mi. 210 mag.

0 0.003 0.020 nCi/Kg III Radiochemica 3 (1) 3H-48 0

Newport 30mi. 30Efmag.

O 27.8 150 nCi/Kg Beach 3 (1) 90Sr-45 1

SONGS II &

III 0.7mi. 215'mag.

0 0.001 0.03 nCi/Kg 1

238U-.1 0

SONGS II &

0.7mi. 215 mag.

0.111 nCi/Kg III

  • Number i ( ) indicates number of locations samplEd in addition to E.T.S. spec fied locati ns

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January -

December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples Background _Name Location Low Mean High Units KELP Ge(Li)Scan Dry Wt.

4 1311-8 0

Barn Kelp 6.6mi. 160amag.

0.05 0.09 0.13 nCi/Kg San Onofre 1.6mi. 195 0mag.

0 0.09 0.18 4

137Cs-8 0

(All samles were below detection linits) nCi/Kg 4

58Co-8 0

(All samfles were below detection li nits) nCi/Kg 4

60Co-8 0

(All sam les were below detection i its) nCi/Kg 4

110mAg-8 0

(All samiles were below detection linits) nCi/Kg 4

95Zr-95Nb-4 0

San Mateo 2.9mi. 2950 mag.

0.15 nCi/Kg Radiochemical 4

3H-8 1

San Mateo 2.9mi. 295 0mag.

0 6

12 nCi/Kg 4

95Zr-95Nb-4 0

Newport 30mi. 3000 mag.

0.16 nCi/Kg

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January - December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

-Name Location Low Mean High Units KELP Ge Li)Scan Wet Wt.

4 1 1I-8 0

San Onofre 1.6mi. 195*mag.

0 0.012 0.024 nCi/Kg 4

137Cs-8 0

(All samlles were.

below detection limits) nCi/Kg 4

58Co-8 0

(All samlles were below detection limits) nCi/Kg 4

60Co-8 0

(All samlles were below detection limits) nCi/Kg 4

11OmAg-8 0

(All samlles were below detection limits) nCi/Kg 4

95Zr-95Nb-4 0

San Onofre 1.6mi. 195 0mag.

0.023 nCi/Kg Radiochemical 4

3H-8 1

San Mateo 2.9mi. 2950 mag.

1.6 nCi/Kg 4

95Zr-95Nb-4 0

Newport 30mi. 3000 mag.

0.021 nCi/Kg

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January -

December. 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

-'Name Location Low Mean High Units OCEAN BOTTOM SEDIMENT Ge(Li)Scan Dry Wt.

5 137Cs-10 SONGS I 0.5mi. 215 0mag.

0.02 0.05 0.07 nCi/Kg 5

58Co-10 1

SONGS I 0.5mi. 215 0mag.

0.02 0.77 1.51 nCi/Kg 5

60Co-10 1

SONGS I 0.5mi. 215 0mag.

0.02 5.26 10.5 nCi/Kg 5

110mAg-10 (All sam les were below detection limits) nCi/Kg 2

54Mn-2 SONGS II 0.8mi. 245 0 mag.

0.64 nCi/Kg 1

65Zn-1 SONGS I 0.5mi. 215 0 mag.

0.34 nCi/Kg 1

144Ce-1 SONGS I 0.5mi. 215 0mag.

0.34 nCi/Kg 5

226Ra-10 SONGS I 0.5mi. 216'mag.

0.23 0.56 0.89 nCi/Kg Decay Chain 5

232Th-100 SONGS I 0.5mi. 215'mag.

0.28 0.61 0.94 nCi/Kg Decay Chain

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January - December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

Name Location Low Mean High Units OCEAN BOTTOM SEDIMENT Ge(Li)Scan Wet Wt.

5 137Cs-10 0

SONGS I 0.5mi. 2150 mag.

0.014 0.04 0.06 nCi/Kg 5

58Co-10 1

SONGS I 0.5mi.

2150mag.

0.014 0.59

-1.16 nCi/Kg 5

60Co-10 1

SONGS I 0.5mi. 2150 mag.

0.014 4.06 8.1 nCi/Kg 5

110mAg-10 0

(All s imples were below dEtection limits) nCi/Kg 2

54Mn-2 0

SONGS I 0.5mi. 2150 mag.

0.49 nCi/Kg 1

65Zn-1 0

SONGS I 0.5mi. 2150 mag.

0.26 nCi/Kg 1

144 Ce-1 0

SONGS I 0.5mi. 2150 mag.

.0.26 nCi/Kg 5

226Ra-10 0

SONGS II 0.8mi. 2450 mag.

0.19 0.47 0.74 nCi/Kg Decay Chain 5

232Th-10 0

SONGS I 0.5mi. 215 0 mag.

0.20 0.46 0.72 nCi/Kg Decay Chain

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January - December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN

  1. of
  1. of Locations I_____

Sampling Total No. of Above Local Medium Locations Samples

Background

Name Location Low Mean High Units SOIL GDry Wt.

Ge(Li)Scan Huntington 137 Beach 37mi. 300amag.

5 Cs-5.0 0.06 nCi/Kg Camp San Onofre 3.Omi. 450mag.

Decay Chain 5

226Ra-5 0

Camp San Onofre 3.Omi. 450 mag.

0.69 nCi/Kg Decay Chain 5

232Th-5 0

Huntington Beach 37mi. 300 0mag.

0.96 nCi/Kg 5

90Sr-50 Camp San Onofre 3.Omi. 450mag.

0.05 nCi/Kg

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January - December, 1980 SAMPLING LOCATION WITH HIGHEST MEAN'

  1. of
  1. of Locations Sampling Total No. of Above Local Medium Locations Samples

Background

Name Location Low Mean High Units JACK RABBIT Femur 1

89Sr-3 0

East of 2.Omi. 450mag-.

0 1

4 pCi/gCa Station 1

90Sr-3 0

East of 2.Omi. 450mag.

4 5

6 pCi/gCa Station Thyroid 1

1311-3 0

(All sa ples were below dEtection limits) pCi/g Dry t Flesh 1

13 7C.s-3 0

(All sa ples were below dEtection limits) pri/g 1 131I-3:

0 (All sanples were below dEtection limits) pCi/g

SAMPLES FOR WHICH RADIONUCLIDE CONTENT WAS GREATER THAN TWICE BACKGROUND LEVEL OF CONTROL LOCATION, JANUARY - DECEMBER, 1980 SAMPLE TYPE LOCATION COLLECTION DATE Air Filter - Gross Beta Visitor Center April 7, 1980 Air Filter - Gross Beta Visitor Center July 28, 1980 Air Filter - Gross Beta San Clemente July 28, 1980 Drinking Water - Gross Beta San Clemente January, 1980 Drinking Water - Gross Beta San Clemente February, 1980 Drinking Water - Gross Beta San Clemente March, 1980 Drinking Water - Gross Beta San Clemente January-March, 1980 Drinking Water (Solids)-Gross Beta San Clemente January-March, 1980 232 Beach Sand - -

Th Surfing Beach January, 1980 226 Beach Sand -

22 Ra Unit 1 - South July, 1980 Beach Sand -

226Ra So. San Onofre July, 1980 State Beach Non-Migratory Marine Animals-58 SONGS I April, June, Dec., 1980 Non-Migratory Marine Animals-5Co SONGS II & III April, June, Dec., 1980 Non0Migratory Marine Animals-Co SNSI &IIApi

,J n,D c,190 NoMigratory Marine Animals-SONGS I April, June, Dec., 1980 J

Co Non-Migratory Marine Animals 60Co SONGS II & III April, June, Dec., 1980 Non-Migratory Marine Animals 110mAg SONGS I April, June, Dec., 1980 Non-Migratory Marine Animals 110g SONGS II & III April, June, Dec., 1980

  • Ocean Bottom Sediment-58Co SONGS I December, 1980
  • Ocean Bottom Sediment-6Co SONGS I December, 1980
  • Possible Correlation with Liquid Releases:

58Co 60Co Annual Total 3.92 Curies 1.67 Curies

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January - March, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements AIR FILTERS (pCi/m 3)

Weekly Gross Beta-65 0.001 0.023 (65/65) Huntington 0.027 (13/13 0.027 (13/13) 0 (0.004-0.048) Beach (0.010-0.046 (0.010-0.046) 37mi. 300amag.

1311-65 0.04

<LLD (0/65)

<LLD (0/13) 0 Quarterly Composite Gross Alpha-5 0.0001 0.0018 (5/5). Huntington 0.0031 (1/1) 0.0031 (1/1) 0 (0.0008-0.0031) Beach 37mi. 300amag.

90Sr-5 0.001

<LLD (0/5)

<LLD (0/13) 0 7Be-5 0.007 0.103 (5/5)

Huntington 0.14 (1/1) 0.14 (1/1) 0 (0.08-0.14).

Beach 37mi. 300 0mag.

137 Cs-5 0.0006 0.0006 (2/5)

Visitor Center 0.0021 (1/1)

<LLD (0/1) 0 (0-0.0021) 0.1mi. 150mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January -

March, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements DIRECT RADIATION (mR)

Quarterly Accumulated 10mR 30.0 (16/16) Huntington 38.2 (1/1) 38.2 (1/1) 0 Dose -

16 (24.4-38.2)

Beach 37mi. 300amag.

DRINKING WATER FILTRATE (pCi/i)

Monthly Gross Alpha 1

1.6 (4/9)

Huntington 2.3 (2/3) 2.3 (2/3) 0 9

(0-5)

Beach (0-4)

(0.4) 37mi. 3000mag.

Gross Beta 0.4 8.0 (9/9)

San Clemente 12.3 (3/3).

4.2 (3/3) 0 9

(3.7-14) 8.7mi. 320amag.

(11-14)

(3.7-5)

Quarterly Composite Gross Alpha 1

0.7 (1/3)

Huntington 2

(1/1) 2 (1/1) 0 3

(0-2)

Beach 37mi. 3000mag.

Gross 3Beta 1

9.7 (3/3)

San Clemente 14 (1/1) 6 (1/1) 0 (6-14) 3.5mi. 320 0mag.

3H-3 200

<LLD (0/3)

<LLD (0/1)

<LLD (0/1) 0

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January - March, 1980 Type and.

Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements DRINKING WATER SOLIDS (pCi/k)

Monthly Gross Alpha 0.1 0.1 (2/9)

Huntington 0.2 (1/3) 0.2 (1/3) 9 (0-0.6)

Beach (0-0.6)

(0-0.6) 37mi. 300 0mag.

Gross Beta 0.1 1.5 (9/9)

San Clemente 1.9 (3/3) 1.1 (3/3) 9 (0.9-2.2) 3.5mi. 320 0mag.

(0.9-1.5)

Quarterly Composite Gross Alpha 0.1 0.2 (2/3)

Huntington 0.4 (1/1) 0.4 (1/1) 0 3

(0.0-0.4)

Beach 37mi. 300 0mag.

Gross Beta 0.1 1.4 (3/3)

San Clemente 2.3 (1/1) 1.0 (1/1) 0 3

(1.0-2.3) 3.5mi. 300amag.

ENVIRONMENTAL RADIOLOGICALITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period January -

March Mediu.

Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements OCEAN WATER (pCi/i)

BiMonthly Gross Beta-8 70 926 (8/8)

SONGS III 965 (2/2) 905 (2/2) 0 (830-1000)

Downcoast (930-1000)

(830-980) 0.7mi. 2150mag.

Ge(Li)Scan 137Cs-8 5

<LLD (0/8)

<LLD (0/2)

<LLD (0/2) 0 BEACH SAND (pCi/g-Dry Wt.)

13C 1.37Cs-4 0.004 0.03 (1/4)

Surfing Beach 0.12 (1/1)

<LLD (0/1) 0 (0-0.12) 1.4mi. 305'mag.

226Ra Decay Chain 4

0.01 0.23 (4/4)

Surfing Beach 0

(0.22-0.24) 1.4mi. 305'mag.

Newport Beach 0.24 (1/1) 0.24 (1/1) 30mi. 305 0mag.

232Th Decay Chain 4

0.02 0.26 1 4 So. San Onofre 0.42 (1/1) 0.16 (1/1) 0 (0.16-u.4 4

State Beaah I1.4mi.

305.'mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period.

April -June, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements AIR FILTE S (pCi/m )

Weekly 1311-65 0.04

<LLD (0/65)

<LLD (0/26)

<LLD (0/13) 0 Gross Beta-65 0.001 0.021.(65/65) Visitor Center 0.026(26/26) 0.019 (13/13) 0 (0.006-0.062) 0.1mi. 150mag.

(0.006-(0.006-0.030) 0.062)

Quarterly Composite Gross Alpha-5 0.0001 0.0011 (5/5)

Huntington 0.0020(2/2) 0.0008 (1/1) 0 (0.0006-Beach (0.0008 0.0015) 37mi.

300amag.

0.0020) 90Sr-5 0.001

<LLD (0/5)

<LLD (0/10)

<LLD (0/1) 0 7Be-5 0.01 0.06 (5/5)

Visitor Center 0.08 (2/2) 0.06 (1/1) 0 (0.05-0.08) 0.1mi. 150mag.

(0.08-0.08) 137Cs-5 0.001

<LLD (0/5)

Units 2&3 0.0006 (1/2)

<LLD (0/1) 0 Switchyard (0-0.0011) 0.6mi. 110'mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April - June, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance MeanTf)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements DIRECT RADIATION (mR)

Quarterly Accumulated Dose -

16 10 24.8 (16/16)

Camp San Mateo 34.2 (2/2) 28.2 (1/1) 0 (20.2-32.2) 3.8mi. 355 0mag. (32.2-36.1)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April -

June, 1980 Type and Lower Limit IAll Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Rane Measurements DRINKING WATER FILTRATE (pCi/z)

Monthly Gross Alpha-9 1

0.8 (3/9)

Huntington 2.0 (4/6)

.1.7 (2/3) 0 (0-3)

Beach (0-4)

(0-3) 37mi.

3000mag.

Gross Beta-9 1

11.1 (9/9)

San Clemente 11.3 (6/6) 8.7 (3/3) 0 (7-19) 3.5mi. 320 0mag. (8-14)

(7-11,)

Quarterly Composite Gross Alpha-3 1

<LLD (0/3)

Huntington 1.0 (1/2)

<LLD (0/1) 0 Beach (0-2) 37mi. 300amag.

Gross Beta-3 1

10.3 (3/3)

San Clemente 12 (2/2) 9 (1/1) 0 (9-13) 3.5mi. 320 0mag. (9-14) 3H-3 200 467 (3/3)

Tri-Cities

'300 (1/2) 500 (1/1) 0 (300-600)

Water District (0-600) 8.7mi.

320 0 mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April - June, 1980

'Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)-

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranoe Measurements DRINKING WATER SOLIDS (pCi/)

Monthly Gross Alpha-9 1

<LLD (0/9)

Huntington 0.1 (1/6)

<LLD (0/3)

Beach (0-0.6) 37mi. 3000mag.

Gross Beta-9 1

0.9 (9/9)

San Clemente 1.4 (6/6) 1.1 (3/3)

(0.8-1.1) 3.5mi. 320 0mag. (0.8-2.2)

(0.8-1.1)

Quarterly Composite Gross Alpha-3 0.1

<LLD (0/3)

Huntington 0.2 (1/2)

<LLD (0/1) 0 Beach (0-0.4) 37mi. 300amag.

Gross Beta-3 0.1 1.8 (3/3)

'San Clemente 2.2 (2/2) 1.8 (1/1) 0 (1.7-2.0) 3.5mi. 320amag..(2.0-2.3)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April -

June, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total.Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements OCEAN WATER (pCi/y)

BiMonthly Gross Beta-4 40 1047 (4/4)

SONGS I Outfall 1043 (3/3) 1250 (1/1) 0 (800-1340) 0.5mi. 2150mag. (890-1340)

Ge(Li)Scan 137 Cs-4 5

408 (1/4)

SONGS I Outfall 144 (1/3)

<LLD (0/1) 0 (0-430) 0.5mi. 215 0mag. (0-430) 60Co-1 2

6 (1/1)

SONGS I Outfall 6 (1/1)

Not Analyzed 1

0.5mi. 2150mag.

58Co-1 5

11 (1/1)

SONGS I Outfall 11 (1/1)

Not Analyzed 1

0.5mi. 2150mag.

134Cs-1 20 380 (1/1)

SONGS I Outfall 380 (1/1)

Not Analyzed 1

0.5mi. 2150mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April -

June, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements OCEAN WATER (pCi/Z)

Semi-Annual Composite 3H-4 200 1150 (2/4)

SONGS I Outfall 1900 (1/1)

<LLD (0/1) 0 (0-1900) 0.5mi. 215 0mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April -

June, 1980 Type and Lower Limit All Indicator Location witIV-Number of Medium or Pathway Total Number of Iao oainwt ubro Sampled (Unit of Analyses Detection Locations Highest Annual Mean Control Locations Nonroutine Smld(nt oAnlss DtcinMean(f)

Name, Distanc Menf Mean ( f Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranoe Measurements NON-MIGRATORY MARINE ANIMALS (nCi/Kg-Dry Wt.)

Ge(Li)Scan 137Cs-24 0.007 0.055 (15/28) SONGS II & III 0.12 (4/8) 0.03 (7/8) 0 (0-0.06) 0.7mi. 215"mag.

(0-0.05)

(0-0.06) 58Co-24 0.01 0.107 (8/24) SONGS II & III 0.16 (4/8)

LLD (0/8) 0 (0-0.54) 0.7mi. 215 0mag.

(0-0.54) 60Co-24 0.01 0.05 (8/24) SONGS II & III 0.08 (4/8)

LLD (0/8) 0 (0-0.23) 0.7mi. 215 0mag. (0-0.23)

IlOmAg-24 0.01 0.12 (8/24) SONGS II & III 0.23 (4/8) 0.03 (2/8)

(0-0.98) 0.7mi. 215 0 mag. (0-0.98)

(0-0.15)

Radiochemical 3H-24 3

154 (14/24) SONGS I 213 (6/8) 161 (6/8)

(0-450) 0.6mi. 215 0mag.

(0-450)

(0-400)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April - June, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual lean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(fY Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranae Measureents NON-MIGRATORY MARINE ANIMALS (nCi/Kg-Dry Wt.)

(Continued)

Radiochemical 90Sr-24 0.02

<LLD (0/24)

<LLD (0/8)

<LLD (0/8) 24 2 38U-1 0.03 0.71 (1/1)

SONGS II

& III 0.71 (1/1)

Not Analyzed 1

0.7mi.

215 0mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April - June, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements NON-MIGRATORY MARINE ANIMALS (nCi/Kg-Wet. Wt.)

Ge(Li)Scan 137Cs-24 0.001 0.005 (14/24) Newport Bach 0.007 (6/8) 0.007 (6/8) 0 (0-0.015) 30mi. 305 mag.

(0-0.015)

(0-0.015) 58Co-24 0.002 0.018 (8/24) SONGS II &III 0.040 (4/8) 0 (0-0.101) 0.7mi. 215 mag. (0-0.101)

<LLD (0/8) 60Co-24 0.002 0.028 (8/24) SONGS I 0.066 (4/8) 0 (0-0.266) 0.6mi. 215 mag.

(0-0.266)

<LLD (0/8) 1lOmAg-24 0.002 0.040 (8/24) SONGS II &.III 0.090 (4/8) 0..005 (2/8) 0 (0-0.14) 0.7mi. 215 mag.

(0-0.33)

(0-0.020)

Radiochemical 3H-24 0.5 34.8 (16/24) SONGS I 49.0 (6/8) 34.9 (6/8) 0 (0-109) 0.6mi. 2150mag.

(0-109)

(0-94) 90Sr-24 0.001

<LLD (0/24) <LLD (0/8)

<LLD (0/8) 0 238U-1 0.006 0.111 (1/1)

SONGS II III 0.111 (1/1)

Not Analyzed 1

O.7mi. 215 mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April - June, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements KELP (nCi/Kg-Dry Wt.)

Ge(Li)Scan 131I-4 0.02 0.10 (4/4)

San Onofre 0.18 (1/1)_

0.11 (1/1) 0 (0.05-0.18) 1.6mi. 195 0mag.

137Cs-4 0.02

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0 58Co'-4 0.02

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0 60Co-4 0.02

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0 11OmAg-4 0.02

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0 Radiochemical 3H-4 5

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April - June, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements KELP (nCi/Kg-Wet. Wt.)

Ge(Li)Scan 11-4 0.002 0.011 (4/4)

San Onofre 0.024 (1/1) 0.009 (1/1) 0 (0.006-0.024) 1.6mi. 195 0 mag.

137Cs-4 0.002

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0 58Co-4 0.002

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0 60Co-4 0.003

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0 110mAg-4 0.002

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0 Radiochemical 3H-4 0.5

<LLD (0/4)

<LLD (0/1)

<LLD (0/1) 0

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April - June,1980 Type and Lower Limit All Indicator Location with-Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranoe Measurements OCEAN BOTTOM SEDIMENT (nCi/Kg-Dry Wt.)

Ge(Li)Scan 137Cs-5 0.01 0.02 (3/5)

SONGS III-0.07 (1/1)

<LLD (0/1) 0 (0-0.07)

Downcoast 0.9mi.

1800mag.

58Co-5 0.01 0.01 (2/5)

SONGS III-0.02 (1/1)

<LLD (0/1) 0 (0-0.02)

Downcoast 0.9mi. 180 amag.

SONGS I Upcoast 0.5mi. 215 0mag 60Co-5 0.01 0.01 (2/5)

SONGS III-0.03 (1/1)

<LLD (0/1) 0 (0-0.03)

Downcoast 0.9mi. 180 0mag 110mAg-5 0.01

<LLD (0/5)

<LLD (0/1)

<LLD (0/1) 0 226Ra-5 0.005 0.22 (5/5)

SONGS I-0.32 (1/1) 0.050 (1/1) 0 Decay Chain (0.05-0.32)

Downcoast 0.5mi. 2150rmag 232Th-5 0.01 0.23 (5/5)

SONGS I-0.31 (1/1) 0.06 (1/1) 0 Decay Chain (0.06-0.31)

Downcoast 0.5mi.

215 0mag

ENVIRONMENTAL.RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California

-Reporting Period April -

June, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranoe Measurements OCEAN BOTTOM SEDIMENT (nCi/Kg-Wet Wt.)

Ge Li)Scan 1li7s-5 0.006 0.015 (3/5)

SONGS III-0.044 (1/1)

<LLD (0/1) 0 (0-0.044)

Downcoast 0.9mi. 180fmag.

58Co-5 0.007 0.005 (2/5)

SONGS I-0.014 (1/1)

<LLD (0/1) 0 (0-0.014)

Upcoast 0.5mi. 215omag 60Co-5 0.007 0.007 (2/5)

SONGS III-0.020 (1/1)

<LLD (0/1) 0 (0-0.020)

Downcoast 0.9mi.

180amag 110mAg-5 0.006

<LLD (0/5)

<LLD (0/1)

<LLD (0/1) 0 226Ra-5 0.004 0.165 (5/5)

SONGS I-0.24 (1/1) 0.038 (1/1) 0 Decay Chain (0.038-0.24)

Downcoast 0.5mi. 215 0mag 232Th-5 0.008 0.175 (5/5)

SONGS I-0.24 (1/1) 0.045 (1/1) 0 Decay Chain (0.045-0.24)

Downcoast 0.5mi. 215 0mag

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period April -

June, 1980 Type admbnde Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean

_ Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance RMean(f7 Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction__ Range Ranae Measurements JACK RABBIT Femur

.(pCi/gCa)*

89Sr-1 3

4 (1/1) 2mi. East 4

(1/1)

None 0

450mag.

90Sr-1 1

6 (1/1) 2mi. East 6

(1/1)

None 0

450mag.

Thyroid (pCi/g) 1311-1 10 LLD (0/1) <LLD (0/1)

None 0

Flesh (pCi/g-Dry Wt.)

137Cs-1 0.04 LLD (0/1)

<LLD (0/1)

None 0

1311-1 0.03 LLD (0/1)

<LLD (0/1)

None 0

  • Note:

0.28+/-0.0 gCa/g Ash

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period July -

September, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements AIR FIL IERS (pCi/m )

Weekly 1311-63 0.04

<LLD (0/63)

<LLD (0/193)

<LLD (0/11) 0 Gross Beta-63 0.001 0.019 (63/63) Visitor Center 0.031 (39/39 0.016 (11/11) 0 (0.007-0.066) O.1mi. 150mag. (0.006-0.062 (0.010-0.033)

Quarterly Composite Gross Alpha-5 0.0003 0.0003 (3/5)

Huntington 0.0015 (3/3) 0.0006 (1/1) 0 (0-0.0006)

Beach (0.0006 37mi. 3000mag.

0.0031) 90Sr-5 0.001

<LLD (0/5)

<LLD (0/15)

<LLD (0/1) 0 7Be-5 0.01 0.05 (5/5)

Huntington 0.09 (3/3) 0.06 (1/1) 0 (0.03-0.07)

Beach (0.06-0.14) 37mi. 3000mag.

137Cs-5 0.001

<LLD (0/5)

Visitor Center 0.0007 (1/3)

<LLD (0/1) 0 0.1mi. 150mag.

(0-0.0021)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period July - September, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements DIRECT RADIATION (mR)

Quarterly Accumulated Dose 25.2 (16/16) Huntington 33.0 (3/3) 32.8 (1/1) 0 16 10 mR (20.7-32.8)

Beach (28.2-38.2) 37mi. 300amag.

DRINKING WATER FILTRATE (pCi/z)

Monthly Gross Alpha-9 1

<LLD (0/9)

Huntington 11.1 (9/9)

<LLD (0/3) 0 Beach (7-19) 37mi. 3000mag.

Gross Beta-9 1

9.8 (9/9)

Tri-Cities 1.3 (4/9) 9.7 (3/3) 0 (6-14)

Water District (0-4)

(6-13) 8.7mi. 3000mag.

Quarterly Composite Gross Alpha-3 2

<LLD (0/3)

Gross Beta-3 1

11 (3/3)

Tri-Cities 12 (3/3)

(9-13)

Water District (9-13) 9 (1/1) 0 8.7mi. 300 0mag 3H-3 200

<LLD (0/3)

Huntington 0 7 (1/3)

Beach (0-2.0)

<LLD (0/1) 0 37mi. 3000mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period July September, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean-Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements DRINKING WATER SOLIDS (pCi/i)

Monthly Gross Alpha-9 0.1 0.04 (1/9)

Huntington 0.07 (1/9)

<LLD (0/3) 0 (0-0.4)

Beach (0-0.6) 37mi. 300amag.

Gross Beta-9 0.1 1.6 (9/9)

Tri-Cities 1.5 (9/9) 1.4 (3/3) 0 (1.0-2.7)

Water District (0.8-2.7)

(1.2-1.6) 8.7mi.

320 0mag.

Quarterly I

Composite Gross Alpha-3 0.1

<LLD (0/3)

Huntington 0.1 (1/3)

<LLD (0/1) 0 Beach (0-0.4) 37mi. 3000mag.

Gross Beta-3 0.1 1.1 (3/3)

San Clemente 1.7 (3/3) 0.9 (1/1) 0 (0.9-1.6)

Well No. 6 (0.9-2.3) 3.5mi. 320amag.

OCEAN WATER (pCi/z)

Bi Monthly Gross Beta-8 40 720 (8/8)

SONGS III 775 (5/5)

(640-820)

Downcoast (730-1000) 645 (2/2) 0 O.7mi. 2150mag.

(640-650)

Ge Li)Scan 5

<LLD (0/8)

SONGS I-Outfall 86 (1/5)

<LLD (0/2) 0 17Cs-8 0.5mi. 215 0mag. (0-430)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period July -

September, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements BEACH SAND (pCi/g-DRY WT.)

137Cs-4 0.01 0.005 (1/4)

Surfing Beach 0.06 (1/2)

<LLD (0/1) 0 (0-0.02) 1.4mi. 305 0 mag. (0-0.12)

Ra Decay 0.01 0.40 (4/4) 0.5mi. South 0.46 (2/2) 0.25 (1/1) 0 Chain (0.14-0.70 of Unit 1 (0.22-0.70) 4 -

0.5mi. 125 0mag.

232Th Decay 0.02 0.46 (4/4)

Surfing Beach 0.43 (2/2) 0.47 (1/1) 0 Chain (0.14-0.62) 1.4mi. 305 0mag. (0.26-0.60) 4

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period July - September, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements LOCAL CROPS (nCi/Kg)

Ge(Li)Scan 1311I-4 0.02

<LLD (0/4)

<LLD (0/2) 0 Ge(Li)Scan 13Cs -

4 0.01

<LLD (0/4)

<LLD (0/2) 0 Radiochemical 90Sr-4 0.04

<LLD (0/4)

<LLD (0/2) 0 Radiochemical 3H-4 4

303 (4/4)

Oceanside 205 (2/2) 205 (2/2) 0 (86-300) 23mi. 135 0 mag.

(110-300)

(110-300)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of.Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements AIR FILTERS (pCi/m3)

.Weekly 1311-64 0.04

<LLD (0/64)

<LLD (0/52)

<LLD (0/13)

Gross Beta-64 0.001 0.090 (64/64) Visitor Center 0.049 (52/52 0.091 (12/12) 0 (0.013-0.204) 0.1mi 15*mag.

(0.006-(0.029-0.194) 0.204)

Quarterly Composite Gross Alpha-5 0.0001 0.0008 (2/5)

Huntington 0.0020 (4/4) 0.0036 (1/1)

(0-0.0036)

Beach (0.0006 37mi. 300 0mag.

0.0036) 90Sr-5 0.001 0.00004 (1/5) San Clemente 0.0001 (1/4)

<LLD (0/1) 0 (0-0.0002) 5.Omi. 320amag. (0-0.0002) 7Be-5 0.01 0.039 (5/5)

Huntington 0.075 (4/4) 0.038 (1/1) 0 (0.03-0.061)

Beach (0.06-0.14) 37mi. 3000mag.

Cs-5 0.001

<LLD (0/5)

<LLD (0/4)

<LLD (0/1) 0

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October -

December. 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)-

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements AIR FILTERS (pCi/m 3 )

Quarterly Composite 141Ce-4 0.001 0.003 (4/4)

San Clemente 0.006 (1/1) 0.002 (1/1) 4 (0.002-0.006) 5.Omi.

320 0mag.

95Zr-5 0.001 0.005 (5/5)

San Clemente 0.011 (1/1) 0.004 (1/1) 5 (0.002-0.011) 5.Omi.

320"mag.

95Nb-5 0.001 0.006 (5/5)

San Clemente 0.014 (1/1) 0.004 (1/1) 5 (0.002-0.014) 5.Omi. 320'mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County,-California Reporting Period October - December, 1980 Ty e and Lower Limit All Indicator Location withlNumber of SM led orft Toal y s s Numo Loca tio ns H

igh es t A nnua l M ean Con tro l Loca t io ns Nonro u t ine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed LLD Range and Direction Range Ranoe Measurements DIRECT RADIATION (mR)

Quarterly Accumulated Dose -

16 10 22.5 (16/16) Huntington 31.1 (4/4) 25.1 (1/1) 0 (18.3-27.4)

Beach (25.1-38.2) 37mi. 3009mag.

Annual Accumulated Dose 3

76.0 (16/16) Huntington 92 (1/1) 92 (1/1) 0 (61-92)

Beach 37mi. 300 %iag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location witf--

Number of Medium or Pathway Total Number of icator Loctin wNu r

Sampled (Unit of Analyses Detection Locations Highest Annual Mean Control Locations Nonroutine ofean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurementge and Direction Range Ranoe Measurements DRINKING WATER FILTRATE (pCi/k)

Monthly Gross Alpha-8 1

0.6 (1/8)

<LLD (0/2)

<LLD (0/2) 0 Gross Beta-8 1

12.5 (8/8)

Tri-Cities 11.8 (12/12) 13.7 (3/3) 0 Water District (7-19)

(10-17) 8.7mi. 320 0mag.

Quarterly Composite Gross Alpha-3 1

1.0 (1/3)

Tri-Cities 1

(1/4)

<LLD (0/1) 0 (0-3)

Water District (0-3) 8.7mi. 320'mag.

Gross Beta-3 1

13 (3/3)

Tri-Cities 13 (4/4) 9 (1/1) 0 (9-16)

Water District (9-16) 8.7mi. 320amag.

3H-3 200

<LLD (0/3)

Tri-Cities 150 (1/4)

<LLD (0/1) 0 Water District (0-600) 8.7mi. 3200mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Meanf)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements DRINKING WATER SOLIDS (pCi/k)

Monthly Gross Alpha-8 1

<LLD (0/8)

Huntington 0.05 (1/11)

<LLD (0/2) 0 Beach (0-0.6) 37mi. 3000mag.

Gross Beta-8 1

1.1 (8/8)

Tri-Cities 1.5 (12/12) 1.2 (3/3) 0 (0.6-2.0)

Water District (0.8-2.7)

(0.6-1.1) 8.7mi. 320amag.

Quarterly Composite Gross Alpha-3 0.1

<LLD (0/3)

Huntington 0.1 (1/4)

<LLD (0/1) 0 Beach (0-0.4) 37mi.

300 0 mag.

Gross Beta-3 0.1 1.4 (3/3)

San Clemente 1.7 (4/4) 1.2 (1/1) 0 (1.2-1.7) 3.5mi. 320amag. (0.9-2.3)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(fY Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements OCEAN WATER (pCi/)

BiMonthly Gross Beta-4 40 893 (4/4)

SONGS I Outfall 903 (6/6) 700 (1/1) 0 (700-1040) 0.5mi. 215 0 mag. (670-1340)

Ge(Li)Scan 137Cs-4 5

<LLD (0/4)

SONGS I Outfall 72 (1/6)

<LLD (0/1) 0 0.5mi. 215 0 mag.

(0-430)

Semiannual Composite 3H-4 200

<LLD (0/4)

SONGS I Outfall 950 (1/2)

<LLD (0/1) 0 0.5mi. 215 0 mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)_

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranqe Measurements NON-MIGRATORY MARINE ANIMALS (nCi/Kg-Dry Wt.)

Ge(Li)Scan 137Cs-24 0.007 0.015 (12/24) SONGS II & III 0.02 (8/16) 0.01 (4/8) 0 (0-0.06) 0.7mi. 215 0rmag. (0-0.06)

(0-0.046) 58Co-24 0.01 0.03 (4/24)

SONGS II & III 0.10 (6/16)

<LLD (0/8) 0 (0-0.31) 0.7mi. 215 0mag. (0-0.54) 60Co-24 0.01 0.11 (9/24)

SONGS II & III 0.11 (8/16) 0.03 (2/8) 0 (0-0.99) 0.7mi. 215 0mag. (0-0.91) 110mAg-24 0.01 0.11 (6/24)

SONGS I 0.169 (5/16)

<LLD (0/8) 0 (0-1.3) 0.6mi. 2150mag. (0-1.3)

Radiochemical 3H-24 3

35.5 (13/24) SONGS I 113 (10/16 64.5 (3/8) 0 (0-450) 0.6mi. 215 0 mag. (0-450)

(0-450) 90Sr-21 0.02 0.003 (1/21)

SONGS II & III 0.004 (1/16)

<LLD (0/8) 21 (0-0.07) 0.7mi. 215 0mag, (0-0.07)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(fy Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranae Measurements NON-MIGRATORY MARINE ANIMALS (nCi/Kg-Wet Wt.)

Ge(Li)Scan 137Cs-24 0.001 0.005 (12/24) SONGS II & III 0.006 (4/8) 0.005 (4/8) 0 (0-0.014) 0.7mi.

215 0 mag.

(0-0.014)

(0-0.014) 58Co-24 0.002 0.004 (4/24)

SONGS I 0.008 (2/8)

<LLD (0/8) 0 (0-0.043)

O.6mi. 215 0 mag.

(0-0.043) 60 Co-24 0.002 0.016 (9/24)

SONGS I 0.024 (3/8) 0.004 (2/8) 0 (0-0.138) 0.6mi. 215 0mag.

(0-0.138)

(0-0.016) 110mAg-24 0.002 0.021 (6/24)

SONGS I 0.043 (3/8)

<LLD (0/8) 0 (0-0.17) 0.6mi. 215 0mag.

(0-0.17)

Radiochemical 3H-24 0.04 10.7 (13/24) Newport Beach 20.7 (3/8) 20.7 (3/8) 0 (0-150) 30mi. 3050mag.

(0-150)

(0-150) 90Sr-21 0.001 0.001 (1/21)

SONGS II & III 0.003 (1/8)

<LLD (0/8) 21 (0-0.03) 0.7mi. 215 0mag.

(0-0.03)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Rane Measurements KELP (nCi/Kg-Dry Wt.)

Ge(Li)Scan 1311-4 0.02 0.07 (2/4)

Barn Kelp 0.09 (2/2) 0.06 (1/1) 0 (0-0.13) 6.6mi. 160mag. (0.05-0.13)

San Onofre Kelp 0.09 (1/2) 1.6mi. 195 0mag.

(0-0.18) 137Cs-4 0.02

<LLD (0/4)

<LLD (0/2)

<LLD (0/1) 0 58Co-4 0.02

<LLD (0/4)

<LLD (0/2)

<LLD (0/1) 0 60Co-4 0.02

<LLD (0/4)

<LLD (0/2)

<LLD (0/1) 0 110mAg-4 0.02

<LLD (0/4)

<LLD (0/2)

<LLD (0/1) 0 95zr 95Nb-4 0.02 0.14 (4/4)

San Mateo Kelp 0.15 (1/1) 0.14 (1/1) 4 2.9mi. 295 iag.

Radiochemical 3H-4 5

3 (1/4)

San Mateo Kelp 6

(1/2)

<LLD (0/1) 0 (0-12) 2.9mi.

295cmag.

(0-12) 95Zr-95Nb-4 0.01 0.12 (4/4)

Newport Kelp 0.16 (1/1) 0.16 (1/1) 4 (0.06-0.16) 30mi. 300 %ag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements KELP (nCi/Kg-Wet Wt.)

Ge(Li)Scan 1311-4 0.002 0.06 (2/4)

San Onofre Kelp 0.012 (1/2) 0.008 (1/1) 0 (0-0.017) 1.6mi. 195 0mag. (0-0.024) 137Cs-4 0.002

<LLD (0/4)

<LLD (0/2)

<LLD (0/1) 0 58Co-40.002

<LLD (0/4)

<LLD (0/2)

<LLD (0/i) 0 60Co-4 0.003

<LLD (0/4)

<LLD (0/2)

<LLD (0/1) 0 110mAg-4 0.002

<LLD (0/4)

<LLD (0/2)

<LLD (0/1) 0 95Zr-95Nb-4 0.002 0.19 (4/4) San Onofre Kelp 0.023 (1/1) 0.018 (1/1) 4 (0.14-0.23) 1.6mi. 1950mag.

Radiochemical 3H-4 0.5 0.4 (1/4) San Mateo Kelp 1.6 (1/1)

<LLD (0/1) 0 (0-1.6) 2.9mi. 295chag.

95Zr-95Nb-4 0.01 0.016 (4/4) Newport Kelp 0.021 (1/1) 0.021 (1/1) 4 (0.008-0.021) 30mi. 300 0mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting -Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Range Measurements OCEAN BOTTOM SEDIMENT (nCi/Kg-Dry Wt.)

Ge(Li)Scan 137Cs-5 0.01 0.04 (4/5)

SONGS I-Upcoast 0.05 (2/2) 0.06 (1/1) 0 (0-0.07) 0.5mi. 215 0mag.

(0.02-0.07) 58Co-5 0.01 0.31 (2/5)

SONGS I-Upcoast 0.77 (2/2)

<LLD (0/1) 0 (0-1.51) 0.5mi. 215*mag.

(0.02-1.51) 60Co-5 0.01 2.15 (2/5)

SONGS I-Upcoast 5.26 (2/2)

<LLD (0/1) 0 (0-10.5) 0.5mi. 215 0mag.

(0.02-10.5) 110mAg-5 0.01

<LLD (0/5)

<LLD (0/2)

<LLD (0/1) 0 226Ra-5 0.005 0.58 (5/5)

SONGS II-0.56 (2/2) 0.42 (1/1) 0 Decay Chain (0.42-0.89)

Upcoast (0.23-0.89) 0.8mi. 245 0mag.

232Th-5 0.01 0.61 (5/5)

SONGS I-Upcoast 0.61 0.51 (1/1) 0 Decay Chain (0.28-0.94) 0.5mi. 215 0mag.

(0.28-0.94)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranae Measurements OCEAN BOTTOM SEDIMENT (nCi/Kg-Dry Wt.)

54Mn-2 0.006 0.33 (2/2)

SONGS I-Upcoast 0.64 (1/1)

Not Analyzed 2

(0.02-0.64) 0.5mi. 215 0mag.

65Zn-1 0.06 0.34 (1/1)

SONGS I-Upcoast 0.34 (1/1)

Not Analyzed 1

0.5mi. 2150mag.

144Ce-1 0.07 0.34 (1/1)

SONGS I-Upcoast 0.34 (1/1)

Not Analyzed 1

0.5mi. 215'mag

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranae Measurements OCEAN BOTTOM SEDIMENT (nCi/Kg-Dry Wt.)

54Mn-2 0.006 0.33 (2/2)

SONGS I-Upcoast 0.64 (1/1)

Not Analyzed 2

(0.02-0.64) 0.5mi. 215 0mag.

65Zn-1 0.06 0.34 (1/1)

SONGS I-Upcoast 0.34 (1/1)

Not Analyzed 1

0.5mi. 215 0mag 144Ce-1 0.07 0.34 (1/1)

SONGS I-Upcoast 0.34 (1/1)

Not Analyzed 1

0.5mi. 215 0mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

'SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October -

December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)T Mean(f)

Reported of Measurement)

Performed (LLD).

Range land Direction Range Ranqe Measurements OCEAN BOTTOM SEDIMENT (nCi/Kg-Wet Wt.)

Ge(Li)Scan 137Cs-5 0.005 0.033 (4/5)

SONGS I-Upcoast 0.04 (2/2) 0.043 (1/1)

(0-0.06) 0.5mj. 215mag. (0.014-0.06) 58Co-5 0.006 0.238 (2/5)

SONGS I-Upcoast 0-.59 (2/2)

<LLD (0/1) 0 (0-1.16) 9.5mi. 215 0mag. (0.014-1.16) 60Co-5 0.01 1.66 (2/5)

SONGS I-Upcoas1 4.06 (2/2)

<LLD (0/1) 0 (0-8.1) 0.5mi. 215 0 mag. (0.014-8.1) 110mAg-5 0.009

<LLD (0/5)

<LLD (0/2)

<LLD (0/1) 0 Decay Chain:

226Ra-5 0.01 0.45 (5/.5)

SONGSII-Upcoast 0.47 (2/2) 0.30 (1/1) 0 (0.25-0.74) 0.8mi. 2450mag (0.19-0.74)

Dm pChain:

Th-5 0.02 0.48 (5/5)

SONGS I-Upcoasi 0.46 (1/1) 0.36 (1/1) 0 (0.23-0.72) 0.5mi. 215 0mag. (0.20-0.72)

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

-SAN ONOFRE NUCLEAR GENERATING STATION -

UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October - December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranoe Measurements OCEAN BOTTOM SEDIMENT (nCi/Kg-Wet Wt.)

Ge(Li)Scan 54Mn-2 0.005 0.253. (2/2)

SONGS I-Upcoasi 0.49 (1/1) Not Analyzed 2

(0.015-0.49) 0.5mi. 215 0mag.

6 5Zn-1 0.05 0.26 (1/1)

SONGS I-Upcoas1 0.26 (1/1)

Not Analyzed 1

0.5mi. 215 0mag.

144Ce-1

'0.06 0.26 (1/1)

SONGS I-Upcoasi 0.26 (1/1) Not Analyzed 1

-0.5mi. 215 0mag,

ENVIRONMENTAL RADIOLOGICAL 9 TORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October -

December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(f)

Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranoe Measurements SOIL (nCi/Kg-Dry Wt.)

Ge(Li)Scan 137Cs-5 0.01 0.03 (3/5)

Huntington 0.06 (1/1) 0.06 (1/1) 0 (0-0.06)

Beach 37mi.

3000nag.

Camp San OnofrE 3.0mi. 450mag.

226Ra-5 Decay Chain 0.02 0.55 (5/5)

Camp San OnofrE 0.69 (1/1) 0.67 (1/1) 0 (0.38-0.69 3.Omi. 450mag.

232Th-5 0.03 0.64 (5/5)

Huntington 0.96 (1/1) 0.96.

(1/1) 0 Decay Chain (0.43-0.96)

Beach 37mi. 300 0 mag.

90Sr-5 0.01 0.02 (3/5)

Camp San OnofrE 0.05 (1/1) 0.03 (1/1) 0 (0-0.05) 3.Omi. 450mag.

ENVIRONMENTAL RADIOLOGICAL MONITORING PROGRAM

SUMMARY

SAN ONOFRE NUCLEAR GENERATING STATION - UNIT 1 Docket No. 50-206 San Diego County, California Reporting Period October -

December, 1980 Type and Lower Limit All Indicator Location with Number of Medium or Pathway Total Number of Locations Highest Annual Mean Control Locations Nonroutine Sampled (Unit of Analyses Detection Mean(f)

Name, Distance Mean(fT Mean(f)

Reported of Measurement)

Performed (LLD)

Range and Direction Range Ranoe Measurements JACK RABBIT Femur (pCi/gCa)*

89Sr-2 1

<LLD (0/2) 2 mi. East 1

(1/3)

None 1

45omag.

90Sr-2 1

5 (0/2) 2 mi. East 5

(3/3)

None 1

450mag.

Thyroid (pCi/g) 11 131I2 2

<LLD (0/2)

<LLD (0/3)

None 1

Flesh (pCi/g-Dry Wt.)

137Cs-2 0.06

<LLD (0/2)

<LLD (0/3)

None 1

1311-2 0.03

<LLD (0/2)

<LLD (0/3)

None 1

  • 0. 37 +/- 0.02 gCa'g ash