Forwards Technical Evaluation of Issues from NRC Staff Action Plan in Response to 851121 Event at San Onofre Unit 1 & EGG-NTA-7204, Assessment of Corrective Actions Taken to Resolve Electrical..., for Review & Comment
ML13324A883
Person / Time
Site: San Onofre 
Issue date: 06/05/1986
From: Novak T
Office of Nuclear Reactor Regulation
To: Baskin K
Southern California Edison Co
Shared Package
ML13324A884 List:
References
NUDOCS 8606130003
Download: ML13324A883 (2)


Text

Docket No.:

50E26 JUN 0 5 1986 Mr. Kenneth P. Baskin, Vice President Nuclear Engineering Safety and Licensing Department Southern California Edison Company 2244 Walnut Grove Avenue P.O. Box 800 Rosemead, California 91770

Dear Mr. Baskin:

SUBJECT:

TRANSMITTAL OF NRC EVALUATION OF TECHNICAL ISSUES RELATED TO THE NOVEMBER 21, 1985 EVENT AT SAN ONOFRE, UNIT 1 Enclosed is the NRC staff's evaluation of certain technical issues related to the November 21, 1985 event. The conclusions herein are based upon our review of your submittals dated March 2, April 8, May 1 and May 5, 1986.

This report is being provided for your review and comment. Modifications to certain portions of the.report may be appropriate if additional information pertinent to the issues is provided to the staff. All comments or additional information provided should be coordinated through your NRC Project Manager.

Sincerely

/5/

Thomas A. Novak, Acting Director Division of PWR Licensing-A

Enclosure:

As stated

  • SEE PREVIOUS CONCURRENCE Office:

PM/PAD#1 PD/PAD#1 Surname: *RDudley/tg

  • GLear vak Date:

06/05/86 06/05/86 06/5/86 8606130003 860605 PDR ADOCK 05000206 S

PDR

JUNy 0 Distribution Copies:

Docket No(s)

NRC PDR Local PDR PAD#1 r/f PAD#1 p/f TNovak, Actg. DD NThompson, DHFT ELD EJordan BGrimes JPartlow GLear RDudley PShuttleworth ACRS (10)

RBallard JMilhoan FRosa VBenaroya JMartin (RV)

AChaffee (RV)