ML13316B302

From kanterella
Jump to navigation Jump to search

Forwards Amend 121 to License DPR-13 & Safety Evaluation. Amend Revises Reactor Trips for Pressurizer High Level & Steam/Feedwater Flow Mismatch
ML13316B302
Person / Time
Site: San Onofre 
Issue date: 04/04/1989
From: Trammell C
Office of Nuclear Reactor Regulation
To: Baskin K
Southern California Edison Co
Shared Package
ML13316B303 List:
References
TAC-71156 NUDOCS 8904200070
Download: ML13316B302 (3)


Text

April 4, 1989 Docket No. 50-206 DISTRIBUTION Docket File (50-206)

NRC & LPDRs BGrimes Mr. Kenneth P. Baskin PD5 Plant File TMeek (4)

Vice President MVirgilio EButcher Southern California Edison Company JLee ACRS (10) 2244 Walnut Grove Avenue OGC-WF GPA/PA Post Office Box 800 DHagan ARM/LFMB Rosemead, California 91770 EJordan WJones CTrammell C.Liang

Dear Mr. Baskin:

SRhow

SUBJECT:

ISSUANCE OF AMENDMENT NO. 121 TO PROVISIONAL OPERATING LICENSE SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 71156)

The Commission has issued the enclosed Amendment No.121 to Provisional Operating License No. DPR-13 for San Onofre Nuclear Generating Station, Unit No. 1. The amendment consists of changes to the Technical Specifications in response to your application dated November 11, 1988, as supplemented February 14, 1989.

The amendment revises the reactor trips for pressurizer high level and steam/feedwater flow mismatch.

Copies of our related Safety Evaluation and Notice of Issuance are also enclosed.

Sincerely, original signed by Charles.M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects

Enclosure:

1. Amendment No. 121 to License No. DPR-13
2. Safety Evaluation
3. Notice of Issuance cc w/enclosures:

See next page

/PD5 D

PD5 NSICB C

DRSP/D:PD5 dramme 1l: dr SNewberry i

,GWKnighton 3/ /89 3/g89 3/,4/89 3/ 9/89

////89 OFFICIAL RECORD COPY 8904200070 890404 PDR ADOCK 05000206 P

PNU

tpjk REGUZ UNITED STATES NUCLEAR REGWkATORY COMMISSIOP WASHINGTON, D. C. 20555 April 4, 1989 Docket No. 50-206 Mr. Kenneth P. Baskin Vice President Southern California Edison Company 2244 Walnut Grove Avenue Post Office Box 800 Rosemead, California 91770 Dear Mr.

Baskin:

SUBJECT:

ISSUANCE OF AMENPMENT NO. 121 TO PROVISIONAL OPERATING LICENSE SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 71156)

The Commission has issued the enclosed Amendment No. 121 to Provisiorl Operating License No. DPR-13 for San Onofre Nuclear Generating Station, Unit No. 1. The amendment consists of changes to the Technical Specifications in response to your application dated kovember 11, 1988, as supplemented February 14, 1989.

The amendment revises the reactor trips for pressurizer high level and steam/feedwater flow mismatch.

Copies of our related Safety Evaluatior and Notice of Issuance are also enclosed.

Sincerely, Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects

Enclosure:

1. Amendment No. 121 to License No. DPR-13
2. Safety Evaluation
3. Notice of Issuance cc w/enclcsures:

See next pace

.Nr. Kenneth P. Baskin San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc Charles R. Kocher, Assistant Mr. Paul Szalinski, Chief General Counsel RadiologicalHealth Branch James Beoletto, Esquire State Department of Health Southern California Edison Company Services Post Office Box 800 714 P Street, Office Bldg. 8 Rosemead, California 91770 Sacramento, California 95814 David R. Pigott Orrick, Herrington & Sutcliffe 600 Montgomery Street San Francisco, California 94111 Mr. Robert G. Lacy 1anager, Nuclear San Diego Gas & Electric Company P. 0. Box 1831 San Diego,,California 92112 Resident Inspector/San Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego 1600 Pacific Highway Room 335 San Diego, California 92101 Director Energy Facilities Siting Division Energy Resources Conservation &

Development Commission 1516 - 9th Street Sacramento, California 95814 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596