Text

May 27, 1983 DISTRIBUTION Docket NRC PDR Local PDR Docket No, 50-206 ORB Reading LSO5-83-05-061 NSIC DCrutchfield HSmith WPaulson Mr. R. Dietch OELD Vice Presic t ELJordan Nuclear Engineering and Operations JMTaylor Southern California Edison Company ACRS (10) 2244 Walnut Grove Avenue SEPB Post Office Box 800 Rosemead, California 91770

Dear Mr. Dietch:

SUBJECT:

REDESIGN OF THE SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 SAFETY INJECTION SYSTEM The NRC staff has completed the review of your September 28, 1982 letter containing conceptual design information regarding a proposed redesign of the San Onofre Unit No. 1 safety injection system. The proposed redesign will separate the feedwater system from the safety injection system.

Based on our review, we find that your conceptual design is acceptable.

The staff's evaluation is enclosed.

Prior to final approval, a more detailed description of the proposed changes will be needed for NRC staff review. Within 60 days of receipt of this letter, please provide your schedule for the submittal of final design details and proposed modifications to the San Onofre Unit No. I technical specifications.

Sincerely, Original signed by/

Den'nis M. Crutchfield, Chief Operating Reactors Branch #5 Division of Licensing

Enclosure:

As stated cc w/enclosure:

See next page 8305310150 830527 0 J PDR ADOCK 05000206

)

S PDR OFFICE.

P HSm

ajs WPadfh'on DCr le1d sURNAME Pr l............

SUR 05

/83 W~05/14/83 05/__________

/83__________

DATE j

.. j.......................................................

NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USGPO: 1981-335-960

Mr. May 27, 1983 cc Charles R. Kocher, Assistant General Counsel James Beoletto, Esquire Southern California Edison Company Post Office Box 800 Rosemead, California 91770 David R. Pigott Orrick, Herrington & Sutcliffe 600 Montgomery Street San Francisco, California 94111 Harry B. Stoehr San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/San Onofre NPS c/o U. S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego San Diego, California 92101 California Department of Health ATTN: Joseph 0. Ward, Chief Radiation Control Unit Radiological Health Section 714 P Street, Room 498 Sacramento, California 95814 U. S. Environmental Protection Agency Region IX Office ATTN:

Regional Radiation Representative 215 Freemont Street San Francisco, California 94111 John B. Martin, Regional Administrator Nuclear Regulatory Commission, Region V 1450 Maria Lane Walnut Creek, California 94596