ML13308B575

From kanterella
Jump to navigation Jump to search
Describes Staffs Recommendations for General Contents of Offsite Dose Calculation Manual.Manual Required W/Proposed Radiological Effluent Tech Specs
ML13308B575
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 02/15/1979
From: Baer R
Office of Nuclear Reactor Regulation
To: James Drake
Southern California Edison Co
References
NUDOCS 7903140104
Download: ML13308B575 (8)


Text

FEB 15 19 Distribution 6Doket File JLee RPDeni se NRC PDR RJMattson ELD Local PDR JPKnight IE(3)

Docket Nos. 50-361 RSBoyd SHanauer DBVassallo RTedesco B~ax M and 50-362 DFRoss RDeYoung JRBuchanan wa-t*FJWilliams VAMoore TBAbernathy RLBaer RHVollmer ACRS(16)

HRood MLErnst Mr. James H. Drake Mr. 3.

14. Gilman Vice President Senior Vice President Southern California Edison Company San Diego Gas and Electric Company 2244 Walnut Grove Avenue 101 Ash Street P. 0. Box 800 P. 0. Box 131 Rosemead, California 91770 San Diego, California 921129 Gentlemen:

SUBJtECT:

CONTENTS OF THE OFFSITF DOSE CALCULATION MANUAL (an OnofreN Nuclear Generatint

Station, EUnits L

and2)

The Radiological Effluent Technical Specifications for R and BWR facil ities issued in November 1978 require you to provide an Cffsite Dose Cal cul ation Manual (ODC) iDth your proposed Tchwical Specifications I

per.'e tin 10 CFR 50.36a and other Federal Regulations.

The enclosure to t-his letter describes the staff's reconrmaendations for the general contents of the 0DC;. The format for the CM is left to your discretion.

Sincerely, HRd M

ssigned b

Robert L.

BaeW Robert L. Raer, Chief LiSht Water Reactors Branch No. 2 Division of Project Management

Enclosure:

(eneral Contents of the 00CM pcs Wlenclosure:

See next page 7903 14010'O(

6FFICE->

~ ~~~~~~~~ ~ ~~~~~~~~~~DP r:LW #21 DPM:LWR #1 DPM:LWR #2.............................................

URNAME*~~U

+a-~oda' RLBa1 FO MDATE~

..... /

79 2/1 '/79..................

21_

NRC o318 n

tRCM 0240 h

sD.

Te ovERNMENT PRINTI ODNICE 7t - 6d6s62c

Mr. James H. Drake Vice President Southern California Edison Company 2244 Walnut Grove Avenue P. 0. Box 800 Rosemead, California 91770 Mr. B. W. Gilman Senior Vice President - Operations San Diego Gas and Electric Company 101 Ash Street P. 0. Box 1831 San Diego, California 92112 cc:

Charles R. Kocher, Esq.

James A. Beoletto, Esq.

Southern California Edison Company 2244 Walnut Grove Avenue P. 0. Box 800 Rosemead, California 91770 Chickering and Gregory ATTN:

David R. Pigott, Esq.

Counsel for San Diego Gas

& Electric Company and Southern California Edison Company Three Embarcadero Center, 23rd Floor San Francisco, California 94112 Mr. Kenneth E. Carr City Manager City of San Clemente 100 Avenido Presidio San Clemente, California 92672 Alan R. Watts, Esq.

Rourke & Woodruff

.1055 North Main Street Suite 1020 Santa Ana, California 92701 Lawrence Q. Garcia, Esq.

California Public Utilities Commission 5066 State Building San Francisco, California 94102

Mr. James H. Drake Mr. B. W. Gilman cc:

Mr. R. W. DeVane, Jr.

Combustion Engineering, Inc.

1000 Prospect Hill Road Windsor, Connecticut 06095 Mr. P. Dragolovich Bechtel Power Corporation P. 0. Box 60860, Terminal Annex Los Angeles, California 90060 Mr. Mark Medford Southern California Edison Company 2244 Walnut Grove Avenue P. 0. Box 800 Rosemead, California 91770 Henry Peters San Diego Gas & Electric Company Post Office Box 1831 San Diego, California 92112 Ms. Lyn Harris Hicks Advocate for GUARD 3908 Calle Ariana San Clemente, California 92672 Richard J. Wharton, Esq.

4655 Cass Street, Suite 304 San Diego, California 92109 Phyllis M. Gallagher, Esq.

Suite 220 615 Civic Center Drive West Santa Ana, California 92701 Mr. Robert J. Pate United States Nuclear Regulatory Commission P. 0. Box 4167 San Clemente, California 92672 1..

how:..

..- NERAL CONTFENTS OF THE ODCM*

Section 1 -

Set Points Provide the eouations and methoddlogy to be used at the station or unit for each alarm and trip set point on each effluent release point according to the Specifications 3.3.3.8 and 3.3.3.9. Provide the alarm and control location, the monitor description, location, power source, scale, range and identification number, and the effluent isolation control device, its location, power source and identification number. If the set point value is variable, provide the equation to be used to predetermine the set point value that will assure that the Specification is met at each release point, and the value to be used when releases are not in progress. If dilution or dispersion is used, describe the on-site equipment and measurement method used during release, the site related parameters and the set points used to assure that the Specification is met at each release point, in cluding any administrative controls applicable at the station or unit.

The fixed and predetermined set points should consider the radioactive effluent to have a radionuclide distribution represented by normal and anticipated operational occurrences. Other features, such as surveillance requirements and the calibration method, should be addressed.

Section 2 - Liquid Effluent Concentration Provide the equations and methodology to be used at the station or unit for each liquid release point according to the Specification 3.11.1.1.

For

  • The format for the ODCM is left up to the licensee and may be simplified by tables and grid printout. Each page should be numbered and indicate the facility approval and effective date.

I.

-2 continuous and/or batch releases, the assumptions used for manual and auto matic termination of reIrases should be provided.

For batch releases, the calculational methods, equations and assumptions used, together with the pre-release and post-release analyses should be provided. Other features, such as surveillance requirements, sampling and analysis program, detection limitations and representative sampling should be addressed.

Section 3 - Gaseous Effluent Dose Rate Provide the equations and methodology to be used at the station or unit for each gaseous release point according to Specification 3.11.2.1. Consider the various pathways, release point elevations, site related parameters and radionuclide contribution to the dose impact limitation. Provide the equa tions and assumptions used, stipulating the pathway, receptor location and receptor age.

Provide the dose factors to be used for the identified radio nuclides released. Provide the annual average dispersion values (X/O and D/Q), the site specific parameters and release point elevations. Other features, such as surveillance requirements, sampling and analysis program, detection limitations and representative sampling should be addressed.

Section 4 - Liquid Effluent Dose Provide the equations and methodology to be used at the station or unit for each liquid release point according to the dose objectives given in Speci fications 3.11.1.2. The section should describe how the dose contributions are to be calculated for the various pathways and release points, the equations and assumptions to be used, the site specific parameters to be

-3 measured and used, the receptor location by direction and distance, and the method of estimating and updating cumulative doses due to liouid releases.

The dose factors, pathway transfer factors, cathIay usace factors, and dilution factors for the points of pathway origin, etc., should be given, as well as receptor age group, water and food consumption rate and other factors assumed or measured. Provide the method of determinino the dilu tion factor at the discharae during any liquid effluent release and any site specific parameters used in these determinations.

Other features such as surveillance requirements, sampl ino and analysis program, detection limitations and representative sampling should be addressed.

Section 5 - Gaseous Effluent Dose Provide the equations and methodology to be used at the station or unit for each gaseous release point according to the dose objectives given in Speci fications 3.11.2.2 and 3.11.2.3. The section should describe how the dose contributions are to be calculated for the various pathways and release points, the equations and assumptions to be used, the site specific para meters to be measured and used, the receptor location by direction and dis tance, and the method estimating and updating cumulative doses due to gaseous releases.

the location direction and distance to the nearest residence, cow, goat, meat.animal, garden, etc., should be given, as well as receptor age group, crop yield, grazing time and other factors assumed or measured. Provide the method of determining dispersion values (X/Q and D/Q) for short-term and long-term releases and any site specific parameters

4 and release point elevations used in these determinations.

Also, provide the criteria for determining short and long term releases.

Other features such as surveillance requirements, sarplino and analysis program, detection limitations and representative sampling should be addressed.

Section 6 - Projected Doses For liquid and gaseous radwaste treatment systems, provide the method of projectino doses due to effluent releases for the normal and alternate path ways of treatment according to the specifications, describing the components and subsystems to be used.

Section 7 - Operability of Equipment Provide a flow diagram(s) defining the treatment paths and the components of the radioactive liquid, gaseous and solid waste management systems that are to be maintained and used, pursuant to 10 CFR 50.36a, to meet Technical Specifications 3.11.1.3, 3.11.2.4 and 3.11.3.1. Subcomponents of packaged equipment can be identified by a list.

For operating reactors whose con struction permit applications were filed prior to January 2, 1971, the flow diagram(s) shall be consistent with the information provided in conformance with Section V.B.1 of Appendix I to 10 CFR Part 50. For OL applications whose construction permits were filed after January 2, 1971, the flow diagram(s) shall be consistent with the information provided in Chapter 11 of the Final Safety Analysis Report (FSAR) or amendments therito.

Section 8 - Sample Locations Provide a nap of the Radiolooical Environmental Ionitorinc Sample Locations indicating the numbered sampling locations given in Table 3.12-1.

Further clarification on these numbered sampling locations can be provided by a list, indicating the direction and distance from the center of the buildina complex of the unit or station, and may include a discriptive name for identification ourDoses.

....