ML13303B101

From kanterella
Jump to navigation Jump to search

Advises That 890508 Response to License Condition 2.C.7 Re Steam Generator/Rcs Delta Temp & Shutdown Cooling Sys Initiation Temp Limits Suitably Conservative,Prior to Five Effective Full Power Yrs,Acceptable
ML13303B101
Person / Time
Site: San Onofre 
Issue date: 06/23/1989
From: Hickman D
Office of Nuclear Reactor Regulation
To: Baskin K, Cotton G
San Diego Gas & Electric Co, Southern California Edison Co
References
TAC-51651 NUDOCS 8907050164
Download: ML13303B101 (3)


Text

June 23, 1989 Docket 'No.:

50-361 Mr. Kenneth P. Baskin Mr. Gary D. Cotton Vice President Senior Vice President Southern California Edison Company Engineering and Operations 2244 Walnut Grove Avenue San Diego Gas and Electric Company Post Office Box 800 101 Ash Street Rosemead, California 91770 Post Office Box 1831 San Diego, California 92112 Gentlemen:

SUBJECT:

LICENSE CONDITION 2.C.7,. SAN ONOFRE NUCLEAR GENERATING STATION, UNIT 2 (TAC NO. 51651)

By letter dated May 8, 1989, you responded to License Condition 2.C.7 of Facility Operating License No. NPF-10 for San Onofre Nuclear Generating Station, Unit 2. This condition required you to verify that the original steam generator/Reactor Coolant System delta temperature and the Shutdown Cooling System initiation temperature limits are still suitably conservative, prior to five effective full power years.of plant operation. The staff has reviewed your response and finds that it satisfies the license condition.

Therefore, no further action is required on your part concerning this issue.

This completes staff action on TAC number 51651.

Sincerely, original. signed by Donald E. Hickman, Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects Office of Nuclear Reactor Regulation cc:

See next page DISTRIBUTION Docket File DHickman NRC & LPDRs OGC PD5 Reading EJordan MVirgilio BGrimes JLee ACRS (10)

WHodges g[02/

T,51651]

DDDRSP/D:PD5 c an:dr MHodges GWKnighton 6/ /89 6//9J89 6/ZV89 OFFICIAL RECORD COPY 8907050164 89062 3 PDR ADOCK 05000361 P

PTC NIS

)'

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 June 23, 1989 Docket No.:

50-361 Mr. Kenneth P. Baskin Mr. Gary D. Cotton vice President Senior Vice President Southern California Edison Company Engineering and Operations 2244 Walnut Grove Avenue San Diego Gas and Electric Company Post Office Box 800 101 Ash Street Rosemead, California 91770 Post Office Box 1831 San Diego, California 92112 Gentlemen:

SUBJECT:

LICENSE CONDITION 2.C.7, SAN ONOFRE NUCLEAR GENERATING STATION, UNIT 2 (TAC NO. 51651)

By letter dated May 8, 1989, you responded to License Condition 2.C.7 ot Facility Operating License No. NPF-10 for San Onofre Nuclear Generating Station, Unit 2. This condition required you to verify that the original steam generator/Reactor Coolant System delta temperature and the Shutdown Cooling System initiation temperature limits are still suitably conservative, prior to five effective full power years of plant operation. The staff has reviewed your response and finds that it satisfies the license condition.

Therefore, no further action is required on your part concerning this issue.

This completes staff action on TAC number 51651.

Sincerely, Donald E. Hickman, Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects uffice of Nuclear Reactor Regulation cc:

See next page

Mr.

Kenneth P. Baskin San Onofre Nuclear Generating Southern California Edison Company Station, Units 2 and 3 cc:

Charles R. Kocher, Esq.

Mr. Mark Medford James A. Beoletto, Esq.

Southern California Edison Company Southern California Edison Company 2244 Walnut Grove Avenue 2244 Walnut Grove Avenue P. 0. Box 800 P. 0. Box 800 Rosemead, California 91770 Rosemead, California 91770 Mr. Robert G. Lacy Orrick, Herrington & Sutcliffe Manager, Nuclear Department ATTN:

David R. Pigott, Esq.

San Diego Gas & Electric Company 600 Montgomery Street P. 0. Box 1831 San Francisco, California 94111 San Diego, California 92112 Alan R. Watts, Esq.

Mr. Gerard C. Wong, Chief Rourke & Woodruff Radiological Materials Control Section 701 S. Parker St. No. 7000 Section Orange, California 92668-4702 State Department of Health Services 714 P Street,, Building #8 Mr. Sherwin Harris Sacramento, California 95814 Resource Project Manager Public Utilities Department Resident Inspector, San Onofre NPS City of Riverside do U.S. NRC; Post Office Box 4329 3900 Main Street San Clemente, California 92112 Riverside, California 92522 Mayor, City of San Clemente Mr. Charles B. Brinkman San Clemente,,California 92672 Combustion Engineering, Inc.

12300 Twinbrook Parkway, Suite 330 Regional Administrator, Region V Rodkville, Maryland 20852 U.S. Nuclear Regulatory Commission 1450 Maria Lane/Suite 210 Mr. Roy Zimmerman Walnut Creek, California 94596 U.S. Nuclear Regulatory Commission Region V Chairman, Board Supervisors 1450 Maria Lane, Suite 210 San Diego County Walnut Creek, California 94596 1600 Pacific Highway, Room 335 San Diego, California 92101 Mr. Don Womeldorf Chief Environmental Mangement Branch Mr. F. B. Marsh, Project Manager California Department of Health Bechtel Power Corporation 714 P Street, Room 616 P.O. Box 60860 Sacramento, California 95814 Terminal Annex Los Angeles, California 90060