April 18, 1988 Docket Nos. 50-361 and 50-362 Mr. Kenneth P. Baskin, Mr. Gary D. Cotton Vice President Senior Vice President Southern California Edison Company Engineering and Operations 2244 Walnut Grove Avenue San Diego Gas and Electric Company Post Office Box 800 101 Ash Street Rosemead, California 91770 Post Office Box 1831 San Diego, California 92112

SUBJECT:

PROPOSED CHANGE TECHNICAL SPECIFICATIONS 3.7-1, "STEAM LINE SAFETY VALVES PER LOOP," PCN 228 -

SAN ONOFRE UNITS 2 AND 3 (TAC NOS. 66494 AND 66495)

Gentlemen:

By letter dated February 27, 1988 you proposed a change to Tecnical Specifi cation Table 3.7-1 for San Onofre Nuclear Generating Station (SONGS) Units 2 and 3 which would remove the Steam Line Safety Valve number designations and orifice sizes from that table.

The staff has reviewed your request and has concluded that the proposed change is not acceptable. With regard to the valve number designations, it is important that there be a specific lift setting associated with a particular valve number. It is not satisfactory to allow the lift setpoint to drift and thereby take credit for a different lift setpoint. Rather, the cause of the drift must be investigated and corrected, if possible, and the valve setpoint must be readjusted. With regard to the orifice size, you have provided no justification for removing that information from the table. Therefore, we are rejecting this request.

If you have any questions regarding this action, please contact me.

Sincerely, original signed by Donald E. Hickman, Project Manager Project Directorate V Division of Reactor Projects - III, IV, V and Special Projects See next page DISTRIBUTION Docket -ile DHickman Local PDRs OGC PDV Reading Edordan GMHolahan JPartlow ACRS (10)

CTrammell DRS

  • DV Hickman:dr G

n 04///88 04//

/88 6604260447 880418 PDR ADOCK 05000361 P

PDR

Mr. Kenneth P. Baskin San Onofre Nuclear Generating Southern California Edison Company Station, Units 2 and 3 cc:

Mr. Gary D. Cotton Mr. Hans Kaspar, Executive Director Senior Vice President Marine Review Committee, Inc.

Engineering and Operations 531 Encinitas Boulevard, Suite 105 San Diego Gas & Electric Company Encinitas, California 92024 101 Ash Street Post Office Box 1831 San Diego, California 92112 Mr. Mark Medford Southern California Edison Company Charles R. Kocher, Esq.

2244 Walnut Grove Avenue James A. Beoletto, Esq.

P. 0. Box 800 Southern California Edison Company Rosemead, California 91770 2244 Walnut Grove Avenue P. 0. Box 800 Mr. Robert G. Lacy Rosemead, California 91770 Manager, Nuclear Department San Diego Gas & Electric Company Orrick, Herrington & Sutcliffe P. 0. Box 1831 ATTN:

David R. Pigott, Esq.

San Diego, California 92112 600 Montgomery Street San Francisco, California 94111 Richard J. Wharton, Esq.

University of San Diego School of Alan R. Watts, Esq.

Law Rourke & Woodruff Environmental Law Clinic 701 S. Parker St. No. 7000 San Diego, California 92110 Orange, California 92668-4702 Charles E. McClung, Jr., Esq.

Attorney at Law Mr. S. McClusky 24012 Calle de la Plaza/Suite 330 Bechtel Power Corporation Laguna Hills, California 92653 P. 0. Box 60860, Terminal Annex Los Angeles, California 90060 Regional Administrator, Region V U.S. Nuclear Regulatory Commission Mr. C. B. Brinkman 1450 Maria Lane/Suite 210 Combustion Engineering, Inc.

Walnut Creek, California 94596 7910 Woodmont Avenue, Suite 1310 Bethesda, Maryland 20814 Resident Inspector, San Onofre NPS c/o U. S. Nuclear Regulatory Commission Mr. Dennis F. Kirsh Post Office Box 4329 U.S. Nuclear Regulatory Commission San Clemente, California 92672 Region V 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Mr. Dennis M. Smith, Chief Radiological Programs Division Governor's Office of Emergency Services 2800 Meadowview Road Sacramento, California 95832