1 NRR-PMDAPEm Resource From:
Lyon, Fred Sent:
Friday, October 25, 2013 6:36 AM To:
'Elwood, Thomas B' (TElwood@ameren.com)
Cc:
Maglio, Scott A (SMaglio@ameren.com)
Subject:
Acceptance Review (TAC No. MF2921)
By letter dated October 17, 2013, Union Electric Company (dba Ameren Missouri, the licensee) submitted relief request I3R-15, Proposed Alternative to ASME Section XI Requirements Regarding System Leakage Tests of Class 1 Piping and Components Isolated Between Normally Closed Valves, for Callaway Plant for the remainder of the current ISI interval.
The purpose of this letter is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staffs acceptance review of relief request I3R-15. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
The NRC staff has reviewed your application and concluded that it provides technical information in sufficient detail to enable the staff to proceed with its detailed technical review and make an independent assessment regarding the acceptability of the proposed relief requests in terms of regulatory requirements and the protection of public health and safety and the environment. If additional information is needed for the staff to complete its technical review, you will be advised by separate correspondence.
Hearing Identifier:
NRR_PMDA Email Number:
886 Mail Envelope Properties (Fred.Lyon@nrc.gov20131025063600)
Subject:
Acceptance Review (TAC No. MF2921)
Sent Date:
10/25/2013 6:36:11 AM Received Date:
10/25/2013 6:36:00 AM From:
Lyon, Fred Created By:
Fred.Lyon@nrc.gov Recipients:
"Maglio, Scott A (SMaglio@ameren.com)" <SMaglio@ameren.com>
Tracking Status: None
"'Elwood, Thomas B' (TElwood@ameren.com)" <TElwood@ameren.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 1444 10/25/2013 6:36:00 AM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: