Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Core Operating Limits Report For Oyster Creek 1 Cycle 24 Prepared:
Reviewed:
Reviewed:
1.
2013.02.19 18:06:38
-05'00' 2013.02.20 10:52:06 -05'00' Reactor Engineering f2:2013.02.20 9
- L 2_
10:23:03 -05'00' Reviewed:
Approved:
Engineering Safety Analysis 2013.02.20 09:37:02 -05'00' Independent Review 2013.07.17 15:38:19 -04'00' GNF - BWR Design Manager S2013.07.24 09:28:03 -04'00' Station Qualified Review Page 1 of 59
1 Exelon Nuclear - Nuclear Fuels COLR Oyster Creek 1 Rev. 9 Core Operating Limits Report For Oyster Creek I Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Table of Contents 1. L is t o f T a b le s.............................................................................................................................................
3 2. R e fe re n c e s................................................................................................................................................
4
- 3. Terms and Definitions...............................................................................................................................
5 4. G e n e ra l In fo rm a tio n..................................................................................................................................
6
- 5. Average Planar Linear Heat Generation Rate.....................................................................................
7
- 6. M inimum Critical Power Ratio................................................................................................................
19 6.1. Manual Flow Control M CPR Lim its...........................................................................................
19 6.2. Power Dependent MCPR Lim its.................................................................................................
19 6.3. S c ra m T im e.....................................................................................................................................
1 9
- 7. Linear Heat Generation Rate.................................................................................................................
23
- 8. Stability Protection Settings...................................................................................................................
24
- 9. Modes of Operation................................................................................................................................
24 1 0. M e th o d o lo g y.........................................................................................................................................
2 5 A p p e n d ix A..........................................................................................................................
2 6 Page 2 of 59
Exelon Nuclear - Nuclear Fuels COLR Oyster Creek 1 Rev. 9 Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390
- 1. List of Tables Table 5-1 MAPLHGR for bundle: GEl 1-P9DUB359-14GZ-10OT-145-T6-3108.................................................................
7 Table 5-2 MAPLHGR for bundle: GE 1-P9DUB359-14GZ-100T-145-T6-3108.................................................................
8 Table 5-3 MAPLHGR for bundle: GEl 1 -P9DUB356-14GZ-10OT-145-T6-3109.................................................................
8 Table 5-4 MAPLHGR for bundle: GE1 1-P9DUB356-14GZ-100T-145-T6-3109.................................................................
9 Table 5-5 MAPLHGR for bundle: GE1 1-P9DUB367-12GZ-100T-145-T6-3104.................................................................
9 Table 5-6 MAPLHGR for bundle: GE1 1-P9DUB367-12GZ-100T-145-T6-3104..............................................................
10 Table 5-7 MAPLHGR for bundle: GEl 1-P9DUB360-1 1GZ-100T-145-T6-3107..............................................................
10 Table 5-8 MAPLHGR for bundle: GE 11-P9DUB360-1 1GZ-10OT-145-T6-3107..............................................................
11 Table 5-9 MAPLHGR for bundle: GEl 1-P9DUB365-10GZ-10OT-145-T6-3105..............................................................
11 Table 5-10 MAPLHGR for bundle: GE1 1-P9DUB365-10GZ-100T-145-T6-3105............................................................
12 Table 5-11 MAPLHGR for bundle: GNF2-P10DG2B370-15GZ-100T2-145-T6-3355..........................................................
12 Table 5-12 MAPLHGR for bundle: GNF2-P1ODG2B371-14GZ-100T2-145-T6-4136..........................................................
13 Table 5-13 MAPLHGR for bundle: GNF2-P10DG2B370-16GZ-100T2-145-T6-4137..........................................................
13 Table 5-14 MAPLHGR for bundle: GNF2-P10DG2B372-14GZ-100T2-145-T6-4138..........................................................
14 Table 5-15 MAPLHGR for bundle: GNF2-P1ODG2B370-16GZ-100T2-145-T6-3356..........................................................
14 Table 5-16 MAPLHGR for bundle: GNF2-P10DG2B369-16GZ-100T2-145-T6-3357-LTD..................................................
15 Table 5-17 MAPLHGR for bundle: GE1 1-P9DUB367-11GZ-100T-145-T6-2921............................................................
15 Table 5-18 MAPLHGR for bundle: GE1 1-P9DUB367-11GZ-100T-145-T6-2921............................................................
16 Table 5-19 MAPLHGR for bundle: GEl 1-P9DUB361-14GZ-10OT-145-T6-2922............................................................
16 Table 5-20 MAPLHGR for bundle: GEl 1-P9DUB361-14GZ-10OT-145-T6-2922............................................................
17 Table 5-21 MAPLHGR for bundle: GE1 1-P9DUB366-12GZ-100T-145-T6-3106............................................................
17 Table 5-22 MAPLHGR for bundle: GEl 1-P9DUB366-12GZ-100T-145-T6-3106............................................................
18 Table 5-23 M APLHG R M ultiplier w ith O ne ISO LATED Loop...............................................................................................
18 T a b le 6 -1 M C P R Lim it - A ll F ue l T ypes................................................................................................................................
2 0 T a b le 6 -2 K f M u ltiplie r - A ll F ue l T ype s................................................................................................................................
2 1 Table 6-3 Power Dependent MCPRp Limits and Multipliers - All Fuel Types.................................................................
22 Table 7-1 Power Dependent LHGR Multiplier LHGRFACp for PROOS..........................................................................
23 Table 7-2 Flow Dependent LHGR Multiplier LHGRFACf for 1 TBVOOS..........................................................................
23 Table 8-1 O ption II Stability Protection Settings...............................................................................................
24 T a b le 9 -1 M o d e s o f O p e ra tio n..............................................................................................................................................
2 4 Page 3 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9
- 2. References
- 1. Deleted.
- 2.
GNF Document, 0000-01 38-9259-SRLR, Revision 2, "Supplemental Reload Licensing Report for Oyster Creek Reload 24 Cycle 24," October 2012.
- 3.
Deleted.
- 4.
Deleted.
- 5.
Deleted.
- 6.
GENE Letter, NSA02-247, "Oyster Creek APRM Flow-Biased Setpoint Margin Between Scram and Rod Block for Stability Option II Adjustment," January 23, 2002.
- 7.
Deleted.
- 8.
Deleted.
- 9.
Deleted.
- 10. EXELON GENERATION COMPANY, LLC OYSTER CREEK GENERATING STATION DOCKET NO. 50-219, Renewed License No. DPR-16
- 11. Deleted.
- 12. Deleted.
- 13. GNF Document, NEDE-24011-P-A-19 and Supplement NEDE-24011-P-A-19-US, "General Electric Standard Application for Reactor Fuel," May 2012 (GESTAR II).
- 14. Exelon TODI, ES1200008, Revision 0, "Final Resolved OPL-3 Parameters for Oyster Creek Cycle 24," dated May 31, 2012.
- 15. GNF/GEH Document, 0000-0155-9047, Revision 0, "Oyster Creek Cycle 24 Operation with 1 TBVOOS," dated December 7, 2012.
Page 4 of 59
Exelon Nuclear - Nuclear Fuels COLR Oyster Creek 1 Rev. 9 Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390
- 3. Terms and Definitions APLHGR Average Planar Linear Heat Generation Rate ARTS APRM, Rod Block Monitor, and Technical Specification (Improvement)
APRM Average Power Range Monitor BOC Beginning of Cycle BWROG Boiling Water Reactor Owner's Group Coastdown Coastdown occurs when full power is not achievable with all rods out, maximum allowable core flow and feedwater temperature reduction, and equilibrium xenon EIS Equipment in Service ELLLA Extended Load Line Limit Analysis EOC End of Cycle EOR End of Rated Conditions (i.e., cycle exposure at 100% power, 100% flow, all-rods-out, all feedwater heaters in service and equilibrium xenon)
FWCF Feedwater Controller Failure GNF Global Nuclear Fuel ICF Increased Core Flow ISOLATED The recirculation loop suction, discharge and discharge bypass valves are in the closed position Kf MCPR flow dependent multiplier (i.e., adjustment to the MCPR limit when at core flow less than rated)
Kp MCPR power dependent multiplier (i.e., adjustment to the MCPR limit when at core power less than rated)
LHGR Linear Heat Generation Rate LHGRFACp LHGR power dependent multiplier (i.e., adjustment to the LHGR limit for the following coincident conditions: at core power less than rated and the pressure regulator is out of service)
LPRM Local Power Range Monitor MAPLHGR Maximum Average Planar Linear Heat Generation Rate MCPR Minimum Critical Power Ratio MCPRp Off-rated power dependent Operating Limit MCPR OOS Out of Service Option A Option A refers to the Technical Specifications core average scram time speed that when applied results in a more restrictive MCPR limit Option B Option B refers to a specific core average scram time speed that when met allows the use of a lower MCPR limit PROOS Pressure Regulator Out of Service RWE Rod Withdrawal Error TBV Turbine Bypass Valve TIP Traversing In Core Probe TBVOOS Turbine Bypass Valve Out of Service Page 5 of 59
Exelon Nuclear - Nuclear Fuels COLR Oyster Creek 1 Rev. 9 Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390
- 4. General Information Oyster Creek is a non-ARTS plant. There are Oyster Creek specific flow-biased and power-biased MCPR operating limits for operation at less than rated flow and power. The flow-biased MCPR limits are discussed in Section 6.1. The power-biased MCPR limits are discussed in Section 6.2. Section 7 provides power-biased LHGR limits for PROOS operating condition and flow-biased LHGR limits for operation with one TBVOOS. Rated core flow is 61 Mlb/hr and operation up to 110.7% of rated is licensed for this cycle. Additionally, Oyster Creek utilizes an ELLLA operating domain, which has expanded the power/flow map to allow for greater operational flexibility.
Page 6 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9
- 5. Average Planar Linear Heat Generation Rate The MAPLHGR limits are discussed in Technical Specifications Section 3.10.A. The MAPLHGR limits for the lattices in each fuel type as a function of average planar exposure are given in Tables 5-1 through 5-22 for operation with zero ISOLATED RECIRCULATION LOOPS (Reference 2). For operation with one ISOLATED RECIRCULATION LOOP, multiply the limits in Tables 5-1 through 5-22 by the ISOLATED Loop multiplier listed in Table 5-23 (Reference 2). All lattices are defined in Appendix A.
Table 5-1 MAPLHGR for bundle: GEl I-P9DUB359-14GZ-1OOT-145-T6-3108 GNF Lattice #8527, #8528, #8508, #8525 Avg. Planar Exposure MAPLHGR (GWdlST)
(kWIft) 0.0 9.64 0.2 9.64 1.0 9.57 5.0 9.39 10.0 9.18 15.0 8.93 20.0 8.95 25.0 8.52 35.0 7.78 45.0 7.59 55.0 7.55 65.0 7.51 Page 7 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 i
Table 5-2 MAPLHGR for bundle: GEl I -P9DUB359-14GZ-100T-145-T6-3108 GNF Lattices #8507, #8526 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kW/ft) 0.0 9.62 0.2 9.62 1.0 9.56 5.0 9.44 10.0 9.17 15.0 8.87 20.0 8.93 25.0 8.52 35.0 7.76 45.0 7.59 55.0 7.55 65.0 7.48 Table 5-3. MAPLHGR for bundle: GEl 1 -P9DUB356-14GZ-1OOT-145-T6-3109 GNF Lattices #8530, #8531, #8508, #8525 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kWlft) 0.0 9.55 0.2 9.55 1.0 9.50 5.0 9.33 10.0 9.04 15.0 8.99 20.0 8.90 25.0 8.51 35.0 7.78 45.0 7.50 55.0 7.55 65.0 7.47 Page 8 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Table 5-4 MAPLHGR for bundle: GE I1-P9DUB356-14GZ-1OOT-145-T6-3109 GNF Lattices #8507, #8529 Avg. Planar Exposure MAPLHGR (GWdlST)
(kWIft) 0.0 9.57 0.2 9.57 1.0 9.56 5.0 9.40 10.0 9.22 15.0 8.92 20.0 8.89 25.0 8.50 35.0 7.78 45.0 7.53 55.0 7.56 65.0 7.53 Table 5-5 MAPLHGR for bundle: GEl 1 -P9DUB367-12GZ-1OOT-145-T6-3104 GNF Lattices #8510, #8511, #8508, #8512 Avg. Planar Exposure MAPLHGR (GWdlST)
(kWIft) 0.0 9.55 0.2 9.55 1.0 9.51 5.0 9.31 10.0 9.10 15.0 8.93 20.0 9.01 25.0 8.68 35.0 7.80 45.0 7.63 55.0 7.60 65.0 7.54 Page 9 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 I
Table 5-6 MAPLHGR for bundle: GE11-P9DUB367-12GZ-1OOT-145-T6-3104 GNF Lattices #8507, #8509 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kW/ft) 0.0 9.58 0.2 9.58 1.0 9.55 5.0 9.29 10.0 9.08 15.0 8.98 20.0 8.96 25.0 8.67 35.0 7.82 45.0 7.63 55.0 7.56 65.0 7.53 Table 5-7 MAPLHGR for bundle: GE11-P9DUB360-11GZ-10OT-145-T6-3107 GNF Lattices #8522, #8523, #8508, #8524 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kWlft) 0.0 9.14 0.2 9.14 1.0 9.10 5.0 9.13 10.0 9.04 15.0 8.93 20.0 8.97 25.0 8.62 35.0 7.78 45.0 7.56 55.0 7.54 65.0 7.45 Page 10 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Table 5-8 MAPLHGR for bundle: GEl 1 -P9DUB360-11GZ-100T-145-T6-3107 GNF Lattices #8507, #8521 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kWIft) 0.0 9.28 0.2 9.28 1.0 9.26 5.0 9.22 10.0 9.09 15.0 8.96 20.0 8.97 25.0 8.58 35.0 7.81 45.0 7.55 55.0 7.54 65.0 7.47 Table 5-9 MAPLHGR for bundle: GEl1-P9DUB365-10GZ-IOOT-145-T6-3105 GNF Lattices #8514, #8515, #8508, #8516 Avg. Planar Exposure MAPLHGR (GWdlST)
(kWlft) 0.0 9.52 0.2 9.52 1.0 9.50 5.0 9.35 10.0 9.14 15.0 9.02 20.0 8.96 25.0 8.65 35.0 7.82 45.0 7.63 55.0 7.58 65.0 7.54 Page 11 of 59 I
Exelon Nuclear - Nuclear Fuels COLR Oyster Creek 1 Rev. 9 Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Table 5-10 MAPLHGR for bundle: GEl I -P9DUB365-1 0GZ-100T-145-T6-3105 GNF Lattices #8507, #8513 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kWIft) 0.0 9.51 0.2 9.51 1.0 9.49 5.0 9.32 10.0 9.16 15.0 8.94 20.0 8.97 25.0 8.65 35.0 7.80 45.0 7.61 55.0 7.59 65.0 7.52 Table 5-11 MAPLHGR for bundle: GNF2-PIODG2B370-15GZ-100T2-145-T6-3355 All Lattices Avg. Planar Exposure MAPLHGR (GWdlST)
(kWlft) 0.0 7.73 0.2 7.73 1.0 7.75 5.0 7.67 10.0 7.64 15.0 7.72 20.0 6.96 25.0 6.46 35.0 6.26 45.0 6.13 55.0 6.03 65.0 5.91 Page 12 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Table 5-12 MAPLHGR for bundle: GNF2-P1 0DG2B371-14GZ-1 00T2-145-T6-4136 All Lattices Avg. Planar Exposure MAPLHGR (GWd/ST)
(kWIft) 0.0 7.75 0.2 7.75 1.0 7.72 5.0 7.63 10.0 7.53 15.0 7.40 20.0 6.86 25.0 6.34 35.0 6.21 45.0 6.06 55.0 5.95 65.0 5.86 Table 5-13 MAPLHGR for bundle: GNF2-P1ODG2B370-16GZ-100T2-145-T6-4137 All Lattices Avg. Planar Exposure MAPLHGR (GWd/ST)
(kW/ft) 0.0 7.73 0.2 7.73 1.0 7.73 5.0 7.66 10.0 7.47 15.0 7.41 20.0 6.89 25.0 6.34 35.0 6.21 45.0 6.05 55.0 5.96 65.0 5.86 Page 13 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Table 5-14 MAPLHGR for bundle: GNF2-P1 0DG2B372-14GZ-1 00T2-145-T6-4138 All Lattices Avg. Planar Exposure MAPLHGR (GWdlST)
(kW/ft) 0.0 7.74 0.2 7.74 1.0 7.72 5.0 7.62 10.0 7.50 15.0 7.40 20.0 6.85 25.0 6.36 35.0 6.21 45.0 6.05 55.0 5.98 65.0 5.86 Table 5-15 MAPLHGR for bundle: GNF2-P1ODG2B370-16GZ-100T2-145-T6-3356 All Lattices Avg. Planar Exposure MAPLHGR (GWdlST)
(kWIft) 0.0 7.83 0.2 7.83 1.0 7.78 5.0 7.73 10.0 7.65 15.0 7.62 20.0 7.76 25.0 6.88 35.0 6.30 45.0 6.17 55.0 6.04 65.0 5.91 Page 14 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Table 5-16 MAPLHGR for bundle: GNF2-P1 0DG2B369-16GZ-100T2-145-T6-3357-LTD All Lattices Avg. Planar Exposure MAPLHGR (GWd/ST)
(kW/ft) 0.0 7.87 0.2 7.87 1.0 7.85 5.0 7.75 10.0 7.70 15.0 7.60 20.0 7.76 25.0 6.83 35.0 6.30 45.0 6.16 55.0 6.03 65.0 5.91 Table 5-17 MAPLHGR for bundle: GElI-P9DUB367-11GZ-IOOT-145-T6-2921 GNF Lattices #7313, #7314, #7315, #7316 Avg. Planar Exposure MAPLHGR (GWdlST)
(kW/ft) 0.0 8.84 0.2 8.84 1.0 8.87 5.0 8.89 10.0 8.93 15.0 8.91 20.0 8.84 25.0 8.18 35.0 7.84 45.0 7.80 55.0 7.86 65.0 7.90 Page 15 of 59 I
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 i
Table 5-18 MAPLHGR for bundle: GE 1I-P9DUB367-11GZ-1OOT-145-T6-2921 GNF Lattices #7311, #7312 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kWlft) 0.0 9.17 0.2 9.17 1.0 9.20 5.0 9.06 10.0 9.02 15.0 8.91 20.0 8.83 25.0 8.16 35.0 7.84 45.0 7.79 55.0 7.84 65.0 7.91 Table 5-19 MAPLHGR for bundle: GEl I -P9DUB361-14GZ-100T-145-T6-2922 GNF Lattices #7318, #7319, #7315, #7320 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kWlft) 0.0 9.39 0.2 9.39 1.0 9.32 5.0 9.23 10.0 8.92 15.0 8.90 20.0 8.76 25.0 8.10 35.0 7.82 45.0 7.77 55.0 7.84 65.0 7.91 Page 16 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Table 5-20 MAPLHGR for bundle: GE 1I-P9DUB361-14GZ-10OT-145-T6-2922 GNF Lattices #7311, #7317 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kWIft) 0.0 9.39 0.2 9.39 1.0 9.33 5.0 9.18 10.0 8.92 15.0 8.88 20.0 8.72 25.0 8.08 35.0 7.83 45.0 7.80 55.0 7.86 65.0 7.91 Table 5-21 MAPLHGR for bundle: GEl I -P9DUB366-12GZ-1OOT-145-T6-3106 GNF Lattices #8518, #8519, #8508, #8520 Avg. Planar Exposure MAPLHGR (GWd/ST)
(kW/ft) 0.0 9.51 0.2 9.51 1.0 9.49 5.0 9.31 10.0 9.08 15.0 8.92 20.0 9.01 25.0 8.68 35.0 7.80 45.0 7.63 55.0 7.57 65.0 7.52 Page 17 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 I
Table 5-22 MAPLHGR for bundle: GE I1-P9DUB366-12GZ-1OOT-145-T6-3106 GNF Lattices #8507, #8517 Avg. Planar Exposure MAPLHGR (GWdlST)
(kW/ft) 0.0 9.52 0.2 9.52 1.0 9.48 5.0 9.34 10.0 9.09 15.0 8.90 20.0 8.97 25.0 8.64 35.0 7.80 45.0 7.62 55.0 7.56 65.0 7.51 Table 5-23 MAPLHGR Multiplier with One ISOLATED Loop
[Isolated Loop Fuel Type Multiplier GEl1 0.98 GNF2 0.98 Page 18 of 59
Exelon Nuclear - Nuclear Fuels COLR Oyster Creek 1 Rev. 9 Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390
- 6. Minimum Critical Power Ratio The MCPR limits are discussed in Technical Specifications Section 3.10.C. For all conditions, the more limiting of the flow adjusted MCPR and power adjusted MCPR is applied.
6.1. Manual Flow Control MCPR Limits The flow adjusted MCPR is determined by multiplying the applicable rated condition MCPR limit shown in Table 6-1 by the applicable MCPR multiplier, Kf, given in Table 6-2. Table 6-1 MCPR limits are the maximum values obtained from analysis of pressurization and non-pressurization events. MCPR values are determined by the cycle-specific fuel reload analyses in Reference 2 and in Reference 15. Table 6-1 MCPR limits are bounding for both GEl 1 and GNF2 fuel. The Kf multipliers are documented in Reference 2 and Reference 15. Table 6-1 limits are independent of APRM status changes since Reference 2 and Reference 15 analyzes the Rod Withdrawal Error (RWE) as unblocked. The appropriate Kf value may be determined by linear interpolation. Table 6-2 is applicable to GEl 1 and GNF2 fuel types per Reference 2 and Reference 15.
Table 6-1 provides two sets of MCPR limits. One set is for "Nominal" response function for the Turbine Bypass Valve (TBV) where the TBV fast opening to 80% of rated TBV flow has been demonstrated to be 1 second or less and has a TBV fast opening delay time of 200 msec or less (Reference 14). The other set, referred to as "Slow to Open", represents MCPR limits which have taken no credit for the fast opening function of the TBV during a Feedwater Controller Failure (FWCF) event. The application of the ("Nominal" versus "Slow to Open") MCPR limits is dependent on the results of TBV testing. Operation with one TBVOOS is independent of the TBV fast opening response time since the 1 TBVOOS MCPR limits in Table 6-1 take no credit for TBV response (References 2 and 15).
6.2. Power Dependent MCPR Limits The use of GNF2 fuel type requires the application of power dependent MCPR limits at off-rated conditions.
Power dependent limits are required because APRM Trip Setdown may not provide adequate protection for the MCPR Safety Limit. Use of these limits ensures that the MCPR Safety Limit is not violated as a result of any anticipated operational occurrence (AOO). Plant specific power dependent MCPR limits are presented in Table 6-3 and documented in Reference 2 and Reference 15. When core thermal power is greater than or equal to 40% of rated, the Kp multiplier from Table 6-3 is applied to the applicable rated condition MCPR limit shown in Tables 6-1. The appropriate MCPRp or Kp value may be determined by linear interpolation. Below 40% of rated power, the MCPR limits in Table 6-3 are applied directly. Table 6-3 is applicable to both GEl 1 and GNF2 fuel types per Reference 2 and Reference 15.
Table 6-3 provides two sets power dependent MCPR limits at off-rated conditions. One set is for "Nominal" response function for the Turbine Bypass Valve (TBV) where the TBV fast opening to 80% of rated TBV flow has been demonstrated to be 1 second or less and has a TBV fast opening delay time of 200 msec or less (Reference 14). The other set, referred to as "Slow to Open", represents power dependent MCPR limits which have taken no credit for the fast opening function of the TBV during a Feedwater Controller Failure (FWCF) event. The application of the ("Nominal" versus "Slow to Open") power dependent MCPR limits is dependent on the results of TBV testing. Operation with one TBVOOS is independent of the TBV fast opening response time since the 1 TBVOOS MCPR limits in Table 6-3 take no credit for TBV response (References 2 and 15).
6.3. Scram Time Core average scram insertion times are determined per Technical Specifications 3.2.B. Based on the results of the scram time surveillance testing and calculation of the core average insertion time, a MCPR limit is chosen from Table 6-1 (Reference 2 and Reference 15). If the core average scram insertion time does not meet the Option B criteria, but has met Option A criteria, then the appropriate MCPR value may be determined from a linear interpolation between the Option A and B limits with standard mathematical rounding to two decimal places.
The scram time adjustment to MCPR only applies to MCPR limits that are set by pressurization transients (see Note 3 to Table 6-1 for further clarification).
Page 19 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Table 6-1 MCPR Limit - All Fuel Types TBV Response Cycle Exposure2 T
pFunction' Option BOC to < (EOR-4016)
- (EOR-4016) MWDIST to Applicability MWDIST EOC Four or Five Recirculation Nominal A
1.54 1.60 Loops in Service EIS or PROOS Nominal B
1.453 1.50 Three Nominal A
Recirculation 1.56 1.62 Loops in Service EIS or PROOS 4 Nominal B
1.473 1.52 Four or Five Slow to Open A
Recirculation 1.58 1.64 Loops in Service EIS or PROOS Slow to Open B
1.48 1.54 Three Slow to Open A
Recirculation 1.60 1.66 Loops in Service EIS or PROOS4 Slow to Open B
1.50 1.56 Four or Five NIA5 A
1.58 1,64 Recirculation Loops in Service I TBVOOS N/A5 B
1.48 1.54 Three N/A5 A
Recirculation 1.60 1.66 Loops in Service I TBVOOS 4 N/A5 B
1.50 1.56 1 Table 6-1 "Nominal" TBV response function MCPR limits assume that ALL Turbine Bypass Valves are in Service. Table 6-1 "Slow to Open" TBV response function MCPR limits are applicable to the slow opening of the TBV as determined by TBV testing.
2 The referenced MCPR cycle exposure breakpoint (EOR-4016) MWD/ST is conservative to the value (EOR-3716) MWD/ST in Reference 2 to allow for changes to the end of rated cycle exposure due to cycle operation.
' The documented MCPR limit is based on the Rod Withdrawal Error (RWE) event, which is a non-pressurization event. The limiting pressurization event results in an Option B MCPR limit that is 0.01 less (BOC to (EOR-4016) MWD/ST) than the RWE event. Scram time adjustments are only required to be applied to MCPR limits that are set by pressurization transients.
4 For three recirculation loops in service, the MCPR operating limit is 0.02 greater than the four/five loop value per Reference 2.
' 1TBVOOS MCPR limits are independent of TBV response function because no credit is taken for the TBV response function.
Page 20 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Table 6-2 Kf Multiplier - All Fuel Types1 Flow I
(% rated) 117.0 1.00 100.0 1.00 90.0 1.00 80.0 1.05 70.0 1.09 60.0 1.13 50.0 1.17 40.0 1.22 30.0 1.28 1 Kf multipliers are applicable for Equipment in Service, PROOS and 1 TBVOOS operating conditions per References 2 and 15.
Page 21 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Table 6-3 Power Dependent MCPRp Limits and Multipliers - All Fuel Types TBV1 Core Flow Core Thermal Power (% of rated)
Applicability
Response
(% of Function rated) 0 25 1 <40
?40 1 60 70 J 79 90 100 Operating Limit MCPR Operating Limit MCPR Multiplier, Kp EIS - Four or Five
< 60 2.52 2.52 2.20 Recirculation Nominal Loops in Service
> 60 2.79 2.79 2.29 1.185 1.185 1.185 1.074 1.000 EIS - Three
< 60 2.54 2.54 2.22 Recirculation Nominal Loops in Service
> 60 2.81 2.81 2.31 1.185 1.185 1.185 1.074 1.000 PROOS - Four or Five
< 60 2.52 2.52 2.20 Recirculation Nominal Loops in Service
> 60 2.79 2.79 2.29 1.517 1.375 1.345 1.265 1.0822 1.000 PROOS - Three
< 60 2.54 2.54 2.22 Recirculation Nominal Loops in Service
> 60 2.81 2.81 2.31 1.517 1.375 1.345 1.265 1.0822 1.000 1 TBVOOS - Four or
< 60 2.67 2.67 2.20 Five N/A3 Recirculation N/A2 Loops in Service
>60 4.02 4.02 2.69 1.193 1.193 1.193 1.082 1.000 1 TBVOOS - Three 3
< 60 2.69 2.69 2.22 Recirculation N/A3 Loops in Service
> 60 4.04 4.04 2.71 1.193 1.193 1.193 1.082 1.000 EIS - Four or Five Slow to
< 60 2.67 2.67 2.20 Recirculation Loopsin Service Open
> 60 4.02 4.02 2.69 1.193 1.193 1.193 1.082 1.000 EIS - Three Slow to
< 60 2.69 2.69 2.22 Recirculation Ow0.
Loops in Service Open
> 60 4.04 4.04 2.71 1.193 1.193 1.193 1.082 1.000 PROOS - Four or Five Slow to
< 60 2.67 2.67 2.20 Recirculation Loops in Service Open
> 60 4.02 4.02 2.69 1.517 1.375 1.345 1.265 1.082 1.000 PROOS - Three Slow to
<60 2.69 2.69 2.22 Recirculation Loops in Service Open
> 60 4.04 4.04 2.71 1.517 1.375 1.345 1.265 1.082 1.000 1 Table 6-3 "Nominal" TBV response function MCPR limits assume that ALL Turbine Bypass Valves are in Service. Table 6-3 "Slow to Open" TBV response function MCPR limits are applicable to the slow opening of the TBV as determined by TBV testing.
2 Kp multiplier has been conservatively set to 1.082 (compared to the Reference 2 value of 1.074) so the PROOS "Nominal" curves can be used for the PROOS "Slow to Open" curves.
3 1TBVOOS MCPR limits are independent of TBV response function because no credit is taken for the TBV response function.
Page 22 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 COLR Oyster Creek 1 Rev. 9
- 7. Linear Heat Generation Rate The LHGR limits are discussed in Technical Specifications Section 3.10.B. The maximum LHGR shall not exceed the LHGR limits as specified in Appendix A. The exposure dependent U0 2 and Gd 20 3 Thermal-Mechanical LHGR limits are contained in Appendix A and apply to all modes of operation as described in Table 9-1. Power dependent LHGR multipliers are listed in Table 7-1 for PROOS operating conditions and are applicable to GEl I and GNF2 fuel types (Reference 2). The power adjusted LHGR for PROOS operating conditions is determined by multiplying the applicable Appendix A LHGR limit by the LHGR multiplier, LHGRFACp, given in Table 7-1. Flow dependent LHGR multipliers are listed in Table 7-2 for one TBVOOS operating condition and are applicable to GEl 1 and GNF2 fuel types (Reference 2 and Reference 15) for operation above 95% core thermal power. The flow adjusted LHGR for one TBVOOS operating condition is determined by multiplying the applicable Appendix A LHGR limit by the LHGR multiplier, LHGRFACf, given in Table 7-2. The appropriate LHGRFACp and LHGRFACf values may be determined by linear interpolation.
Table 7-1 Power Dependent LHGR Multiplier LHGRFACp for PROOS Power LHGRFACp
(% rated)
LHGRFA_
0.0 0.702 40.0 0.702 50.0 0.760 60.0 0.808 70.0 0.891 79.0 0.905 90.0 1.000 100.0 1.000 Table 7-2 Flow Dependent LHGR Multiplier LHGRFACf for I TBVOOS Flow LHGRFACf 1
(% rated) 117.0 1.000 100.0 1.000 90.0 0.999 80.0 0.917 70.0 0.842 60.0 0.760 50.0 0.671 40.0 0.596 30.0 0.495 1 The off-rated flow dependent LHGRFACf limits for 1 TBVOOS are required for operation above 95% core thermal power.
Page 23 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 COLR Oyster Creek 1 Rev. 9
- 8. Stability Protection Settings The stability protection settings are discussed in Technical Specifications 2.3. Oyster Creek utilizes the BWROG Option II solution in the licensing stability calculations. Table 8-1 provides the analytical limit equations for APRM based stability protection settings and related Control Rod Block settings to support Option II implementation (References 2 and 6).
Table 8-1 Option II Stability Protection Settings Technical Specification 2.3.A.1 Neutron Flux, Scram - APRM ForW<_
27.5x10 61b/hr:
S*_
(1.433 x 10-6) W + 24.8 where:
S = setting in percent of rated power W = recirculation flow (lb/hr)
Technical Specification 2.3.B Neutron Flux, Control Rod Block ForW*_
27.5 x 106 lb / hr:
S*< (1.433x 10-6)W+ 17.5 where:
S = setting in percent of rated power W = recirculation flow (lb/hr)
- 9. Modes of Operation The allowed Modes of Operation are as described in Table 9-1.
Table 9-1 Modes of Operation Operating Region Options1' 3 Standard ELLLA ICF2 Five-loop Operation, Option A or B Yes Yes Yes Four-loop Operation, Option A or B Yes Yes Yes Three-loop Operation, Option A or B Yes Yes Yes PROOS, Five-loop Operation, Option A or B Yes Yes Yes PROOS, Four-loop Operation, Option A or B Yes Yes Yes PROOS, Three-loop Operation, Option A or B Yes Yes Yes 1 TBVOOS, Five-loop Operation, Option A or B Yes Yes Yes 1 TBVOOS, Four-loop Operation, Option A or B Yes Yes Yes 1 TBVOOS, Three-loop Operation, Option A or B Yes Yes Yes 1 Each operational mode may be combined with up to a 100°F reduction in feedwater temperature (Final Feedwater Temperature Reduction or Feedwater Heaters OOS) at any point in the cycle (Reference 2 and Reference 15).
2 Operation up to 67.5 Mlb/hr core flow is licensed for this cycle (Reference 2).
3 Each operational mode may be coincident with coastdown operation. The minimum coastdown power level is 40% per GESTAR II (Reference 13).
Page 24 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9
- 10. Methodology
- 1. GENE Document, NEDC-31462P and NEDE-31462, "Oyster Creek NGS SAFER/CORECOOUGESTR-LOCA Loss-of-Coolant Accident Analysis," August 1987.
- 2.
GNF Document, NEDE-24011-P-A-19 and Supplement NEDE-24011-P-A-19-US, "General Electric Standard Application for Reactor Fuel," May 2012.
- 3.
GENE Document, NEDC-33065P, Rev. 0, "Application of Stability Long-Term Solution Option II to Oyster Creek,"
April 2002.
Page 25 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 COLR Oyster Creek 1 Rev. 9 Appendix A Page 26 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 COLR Oyster Creek 1 Rev. 9 Global Nuclear Fuel A Joint Vulu~r of GE.Toshiha. & Hitachi Global Nuclear Fuel 0000-0138-9259-FBIR-NP Revision 0 September 2012 Non-Proprietary Information - Class I (Public)
Fuel Bundle Information Report for Oyster Creek Reload 24 Cycle 24 Copyright 2012 Global Nuclear Fuel - Americas, LLC All Rights Reserved Page 27 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 COLR Oyster Creek 1 Rev. 9 Oyster Creek Non-Proprietary Information 0000-0138-9259-FBIR-NP Reload 24 Class I (Public)
Revision 0 Important Notice Regarding Contents of This Report Please Read Carefully This report was prepared by Global Nuclear Fuel - Americas, LLC (GNF-A) solely for use by Exelon
("Recipient") in support of the operating license for Oyster Creek (the "Nuclear Plant"). The information contained in this report (the "Information")
is believed by GNF-A to be an accurate and true representation of the facts known by, obtained by or provided to GNF-A at the time this report was prepared.
The only undertakings of GNF-A respecting the Information are contained in the contract between Recipient and GNF-A for nuclear fuel and related services for the Nuclear Plant (the "Fuel Contract") and nothing contained in this document shall be construed as amending or modifying the Fuel Contract. The use of the Information for any purpose other than that for which it was intended under the Fuel Contract, is not authorized by GNF-A. In the event of any such unauthorized use, GNF-A neither (a) makes any representation or warranty (either expressed or implied) as to the completeness, accuracy or usefulness of the Information or that such unauthorized use may not infringe privately owned rights, nor (b) assumes any responsibility for liability or damage of any kind which may result from such use of such information.
Information Notice This is a non-proprietary version of the document 0000-0138-9259-FBIR-P, Revision 0, which has the proprietary information removed. Portions of the document that have been removed are indicated by an open and closed bracket as shown here ((
)).
Page 2 Page 28 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 COLR Oyster Creek 1 Rev. 9 Oyster Creek Non-Proprietary Information 0000-01 38-9259-FBIR-NP Reload 24 Class I (Public)
Revision 0
- 1. Introduction and Summary This report, which supplements the Supplemental Reload Licensing Report, contains thermal-mechanical linear heat generation rate (LHGR) limits for the GNF-A fuel designs to be loaded into Oyster Creek for Cycle 24. These LHGR limits are obtained from thermal-mechanical considerations only. Approved GNF-A calculation models documented in Reference 1 were used in performing this analysis.
LHGR limits as a function of exposure for each bundle of the core design are given in Appendix A. The LHGR values provided in Appendix A provide upper and lower exposure dependent LHGR boundaries which envelope the actual gadolinia dependent LHGR limits. The LHGRs reported have been rounded to two places past the decimal.
Appendix B contains a description of the fuel bundles. Table B-I contains a summary of bundle-specific information, and the figures provide the enrichment distribution and gadolinium distribution for the fuel bundles included in this appendix. These bundles have been approved for use under the fuel licensing acceptance criteria of Reference 1.
Page 3 Page 29 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0
- 2. References
- 1. General Electric Standard Application for Reactor Fuel, NEDE-240 11-P-A-i19, May 2012; and the U.S. Supplement, NEDE-2401 1-P-A-19-US, May 2012.
Page 4 Page 30 of 59
Exelon Nuclear-Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 Appendix A UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GEl I-P9DUB359-14GZ-1OOT-145-T6-3108 (GEl 1)
Bundle Number: 3108 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 20.00 (18.14) 10.50 70.00 (63.50) 6.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit't GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 10.29 16.52 (14.99) 9.00 63.65 (57.74) 5.14 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).
Page 5 Page 31 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0138-9259-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GEl I-P9DUB356-I4GZ-IOOT-145-T6-3109 (GEl 1)
Bundle Number: 3109 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 20.00(18.14) 10.50 70.00 (63.50) 6.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 2 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 10.29 16.52 (14.99) 9.00 63.65 (57.74) 5.14 2 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).
Page 6 Page 32 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 U02/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE1 I-P9DUB367-12GZ-100T-145-T6-3104 (GEl 1)
Bundle Number: 3104 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 20.00 (18.14) 10.50 70.00 (63.50) 6.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 3 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 10.29 16.52 (14.99) 9.00 63.65 (57.74) 5.14 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).
Page 7 Page 33 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GEl 1-P9DUB360-1 IGZ-IOOT-145-T6-3107 (GEl 1)
Bundle Number: 3107 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 20.00 (18.14) 10.50 70.00 (63.50) 6.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 4 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 10.29 16.52 (14.99) 9.00 63.65 (57.74) 5.14 4 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).
Page 8 Page 34 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-013 8-9259-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GEl I-P9DUB365-IOGZ-IOOT-I45-T6-3105 (GEl 1)
Bundle Number: 3105 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 20.00 (18.14) 10.50 70.00 (63.50) 6.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 5 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 10.29 16.52 (14.99) 9.00 63.65 (57.74) 5.14 5 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).
Page 9 Page 35 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GN F2-P 1 ODG2B370-16GZ-100T2-145-T6-4137 (GNF2)
Bundle Number: 4137 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 6 GWd/MT (GWd/ST) kW/ft
((___________________
6 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ((
Page 10 Page 36 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Piihlic'*
COLR Oyster Creek 1 Rev. 9 0000-0 1 38-9259-FBIR-NP Revision 0 eload 24 Class I (Public)
U0 2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-PI ODG2B370-15GZ-100T2-145-T6-3355 (GNF2)
Bundle Number: 3355 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 7 GWd/MT (GWd/ST) kW/ft
((I___________________
7 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ((
Page 11 Page 37 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-PI ODG2B370-16GZ-100T2-145-T6-3356 (GNF2)
Bundle Number: 3356 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft
((I Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' GWd/MT (GWd/ST) kW/ft
((I 8 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ((
I].
Page 12 Page 38 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0138-9259-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-PI 0DG2B369-16GZ-100T2-145-T6-3357-LTD (GNF2)
Bundle Number: 3357 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit 9 GWd/MT (GWd/ST) kW/ft
((___________________
9 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design ((
I].
Page 13 Page 39 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-P 1 ODG2B3 72-14GZ-I 00T2-145-T6-4138 (GNF2)
Bundle Number: 4138 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' 0 GWd/MT (GWd/ST) kW/ft I((___________________
'o Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design Page 14 Page 40 of 59
Exelon Nuclear-Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0138-9259-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GEl I-P9DUB367-1 IGZ-100T-145-T6-2921 (GEl 1)
Bundle Number: 2921 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 20.00 (18.14) 10.50 70.00 (63.50) 6.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit'1 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 10.29 16.52 (14.99) 9.00 63.65 (57.74) 5.14 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).
Page 15 Page 41 of 59
Exelon Nuclear-Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Puhlic)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 U02/Gd Thermal-Mechanical LHGR Limits Bundle Type: GEl l-P9DUB361-14GZ-1 OOT-145-T6-2922 (GEl 1)
Bundle Number: 2922 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 20.00 (18.14) 10.50 70.00 (63.50) 6.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' 2 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 10.29 16.52 (14.99) 9.00 63.65 (57.74) 5.14 12 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).
Page 16 Page 42 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0138-9259-FBIR-NP Revision 0 evision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GE I -P9DUB366-12GZ-LOOT-I 45-T6-3106 (GEl 1)
Bundle Number: 3106 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 12.00 20.00 (18.14) 10.50 70.00 (63.50) 6.00 Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' 3 GWd/MT (GWd/ST) kW/ft 0.00 (0.00) 10.29 16.52 (14.99) 9.00 63.65 (57.74) 5.14 13 Bounding gadolinia LHGR limit for all gadolinium concentrations occurring in this bundle design (7.0% Gd).
Page 17 Page 43 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-013 8-9259-FBIR-NP Revision 0 UO2/Gd Thermal-Mechanical LHGR Limits Bundle Type: GNF2-PI 0DG2B371-14GZ-100T2-145-T6-4136 (GNF2)
Bundle Number: 4136 Peak Pellet Exposure U0 2 LHGR Limit GWd/MT (GWd/ST) kW/ft
((I Peak Pellet Exposure Most Limiting Gadolinia LHGR Limit' 4 GWd/MT (GWd/ST) kW/ft 14 Bounding gadolinia LHGR limit for all gadolinium
((
1].
concentrations occurring in this bundle design Page 18 9
Page 44 of 5
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0138-9259-FBIR-NP Revision 0 Appendix B Fuel Bundle Information Table B-1 Bundle Specific Information Max Exposure Fuel Bundle Enrichment Weight Weight k at at Max k.
of UO2 of U Bundle Number (wt% U-235) 200C GWd/MT (kg)
(kg) 15 (GWd/ST)
G E II-P9DUB359-14GZ-IOOT-3108 145-T6-3108 (GEl I)
GEl 1-P9DUB356-l4GZ-100T-3109 145-T6-3109 (GEl 1)
GE 1 I-P9DUB367-l2GZ-100T-3104 145-T6-3104 (GEl 1)
GEl 1-P9DUB360-11 GZ-100T-145-T6-3107 (GE 13)
GEl 1-P9DUB365-l OGZ-IOOT-3105 145-T6-3105 (GEl I)
GNF2-P 1 0DG2B3 70-16GZ-100T2-145-T6-4137 (GNF2)
GNF2-P1 ODG2B3 70-i 5GZ-3355 100T2-145-T6-3355 (GNF2)
GNF2-PI 0DG2 B3 70-16GZ-100T2-145-T6-3356 (GNF2)
GNF2-P10DG2B369-16GZ-100T2-145-T6-3357-LTD 3357 (GNF2)
GNF2-P 10DG2B3372-i4GZ-100T2-145-T6-4138 (GNF2)
GEl 1-P9DUB367-1 IGZ-100T-2921 145-T6-2921 (GEl I)
GEl 1-P9DUB361-14GZ-IOOT-2922 145-T6-2922 (GEL 1)
GEl 1-P9DUB366-12GZ-IOOT-3106 145-T6-3106 (GE 11)
GNF2-PI 0DG2B371-14GZ-100T2-145-T6-4136 (GNF2) 4136 "S Maximum lattice k. for the most reactive uncontrolled state plus a ((
)) adder for uncertainties.
Page 19 Page 45 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 Figure B-I Enrichment and Gadolinium Distribution for EDB No. 3108 Fuel Bundle GEll-P9DUB359-14GZ-100T-145-T6-3108 (GEl1)
Page 20 Page 46 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0 1 38-9259-FBIR-NP Revision 0 Figure B-2 Enrichment and Gadolinium Distribution for EDB No. 3109 Fuel Bundle GEl 1-P9DUB356-14GZ-100T-145-T6-3109 (GEl1)
Page 21 Page 47 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 11 Figure B-3 Enrichment and Gadolinium Distribution for EDB No. 3104 Fuel Bundle GEI-P9DUB367-12GZ-100T-145-T6-3104 (GE11)
Page 22 Page 48 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 Figure B-4 Enrichment and Gadolinium Distribution for EDB No. 3107 Fuel Bundle GEl1-P9DUB360-11GZ-100T-145-T6-3107 (GEl1)
Page 23 Page 49 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-013 8-9259-FBIR-NP Revision 0 Figure B-5 Enrichment and Gadolinium Distribution for EDB No. 3105 Fuel Bundle GEl I-P9DUB365-10GZ-100T-145-T6-3105 (GEl1)
Page 24 Page 50 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-013 8-9259-FBIR-NP Revision 0 1]
Figure B-6 Enrichment and Gadolinium Distribution for EDB No. 4137 Fuel Bundle GNF2-P1ODG2B370-16GZ-100T2-145-T6-4137 (GNF2)
Page 25 Page 51 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0138-9259-FBIR-NP Revision 0 Figure B-7 Enrichment and Gadolinium Distribution for EDB No. 3355 Fuel Bundle GNF2-P1ODG2B370-15GZ-100T2-145-T6-3355 (GNF2)
Page 26 Page 52 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0 1 38-9259-FBIR-NP Revision 0 1]
Figure B-8 Enrichment and Gadolinium Distribution for EDB No. 3356 Fuel Bundle GNF2-P1ODG2B370-16GZ-100T2-145-T6-3356 (GNF2)
Page 27 Page 53 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 Figure B-9 Enrichment and Gadolinium Distribution for EDB No. 3357 Fuel Bundle GNF2-P10DG2B369-16GZ-100T2-145-T6-3357-LTD (GNF2)
Page 28 Page 54 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 10CFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 Figure B-10 Enrichment and Gadolinium Distribution for EDB No. 4138 Fuel Bundle GNF2-PIODG2B372-14GZ-100T2-145-T6-4138 (GNF2)
Page 29 Page 55 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0 Figure B-11 Enrichment and Gadolinium Distribution for EDB No. 2921 Fuel Bundle GElI-P9DUB367-11GZ-100T-145-T6-2921 (GEl1)
Page 30 Page 56 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0 1 38-9259-FBIR-NP Revision 0
((
Figure B-12 Enrichment and Gadolinium Distribution for EDB No. 2922 Fuel Bundle GEl1-P9DUB361-14GZ-lOOT-145-T6-2922 (GEl1)
Page 31 Page 57 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-01 38-9259-FBIR-NP Revision 0
[1 1]
Figure B-13 Enrichment and Gadolinium Distribution for EDB No. 3106 Fuel Bundle GEl1-P9DUB366-12GZ-100T-145-T6-3106 (GEl1)
Page 32 Page 58 of 59
Exelon Nuclear - Nuclear Fuels Core Operating Limits Report For Oyster Creek 1 Cycle 24 Non-Proprietary Information Submitted in Accordance with 1 OCFR2.390 Oyster Creek Non-Proprietary Information Reload 24 Class I (Public)
COLR Oyster Creek 1 Rev. 9 0000-0138-9259-FBIR-NP Revision 0 Figure B-14 Enrichment and Gadolinium Distribution for EDB No. 4136 Fuel Bundle GNF2-P1ODG2B371-14GZ-100T2-145-T6-4136 (GNF2)
Page 33 Page 59 of 59