ML13127A146

From kanterella
Jump to navigation Jump to search

Email Table 2 Response Question
ML13127A146
Person / Time
Site: River Bend Entergy icon.png
Issue date: 05/06/2013
From: Fountain W
Entergy Operations
To: Wang A
Plant Licensing Branch IV
Wang A
References
TAC ME7951
Download: ML13127A146 (1)


Text

From: FOUNTAIN, WILLIAM J To: Wang, Alan Cc: CLARK, JOSEPH A; Plumlee, Curtis; ROBERTS, JERRY C

Subject:

FW: Table 2 response question.

Date: Monday, May 06, 2013 4:00:39 PM Mr. Wang, After our conference call today, River Bend Station is providing the following clarification in regard to the Planned or Potential Improvements Identified? in Table 2 of our February 22, 2013, Entergys Response to NRC Technical Issues for Resolution Regarding Licensee Communication Submittals Associated with Near-Term Task Force Recommendation 9.3 (TAC No. ME7951) submittal per RBG-47335:

Bill Fountain River Bend Station Licensing From: TISON, NORMAN E Sent: Monday, May 06, 2013 2:58 PM To: FOUNTAIN, WILLIAM J

Subject:

Table 2 response question.

The deployment of satellite phones for our Control Room and our Technical Support Center [TSC]

was discussed earlier in the submittal on page 17. Since the satellite phones had already been deployed in both of these locations, they were not identified as a planned or potential improvement for the Main Control Room or the TSC in our Table 2 response.

Norman Tison River Bend Station Emergency Preparedness