UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555"()001 April 25, 2013 Mr. George H. Gellrich, Vice President Calvert Cliffs Nuclear Power Plant, LLC Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702
SUBJECT:
CALVERT CLIFFS NUCLEAR POWER PLANT, UNIT NOS. 1 AND 2 REQUEST FOR ADDITIONAL INFORMATION REGARDI NG CALCULATED PEAK CONTAINMENT INTERNAL PRESSURE LICENSE AMENDMENT (TAC NOS. ME9081 AND ME9082)
Dear Mr. Gellrich:
By letter dated July 2, 2012, as supplemented by letter dated March 6, 2013, Calvert Cliffs Nuclear Power Plant, LLC submitted a license amendment request to revise the calculated peak containment internal pressure for the design basis loss-of-coolant accident in Technical Specification (TS) 5.5.16, "Containment Leakage Rate Testing Program" and the initial internal containment pressure limit in TS 3.6.4, "Containment Pressure" for Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2.
The Nuclear Regulatory Commission (NRC) staff is reviewing the submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). The NRC staff is requesting a response to the RAI within 30 days of the date of this letter.
If you have any questions regarding this issue, please contact me at (301) 415-1016.
Sincerely,
.//7
~ /~.
Nadiyah S. Morgan, Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor licenSing Office of Nuclear Reactor Regulation
~
Docket Nos. 50-317 and 50-318
Enclosure:
RAI cc w/encl: Distribution via Listserv
REQUEST FOR ADDITIONAL INFORMATION REGARDING PEAK CONTAINMENT INTERNAL PRESSURE LICENSE AMENDMENT REQUEST CALVERT CLIFFS NUCLEAR POWER PLANT, LLC.
CALVERT CLIFFS NUCLEAR POWER PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-317 AND 50-318 By letter dated July 2, 2012 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML12187A250), as supplemented by letter dated March 6, 2013 (ADAMS Accession No. ML13070A078), Calvert Cliffs Nuclear Power Plant, LLC, submitted a license amendment request (LAR) to revise the calculated peak containment internal pressure for the design basis loss-of-coolant accident (LOCA) in Technical Specification (TS) 5.5.16, "Containment Leakage Rate Testing Program" and the initial internal containment pressure limit in TS 3.6.4, "Containment Pressure" for Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2.
In order to complete its review, the Nuclear Regulatory Commission (NRC) staff needs the following additional information:
- 1. In regard to your response to the NRC staff's request for additional information question number 5 in letter dated February 6, 2013 (ADAMS Accession No. ML13036A237), provide justification on how equipment qualification (EQ) remains bounded for all points of the figures provided in Attachment 1 of your March 6, 2013, letter. Also, explain how margins are being maintained for equipment required to meet Title 10 of the Code of Federal Regulations Section 50.49.
- 2. Provide a discussion on any impact of the proposed change on areas of the plant outside of containment (e.g., changes to EQ parameters such as temperature and pressure).
April 25, 2013 Mr. George H. Gellrich, Vice President Calvert Cliffs Nuclear Power Plant, LLC Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702 SUB~IECT:
CALVERT CLIFFS NUCLEAR POWER PLANT, UNIT NOS. 1 AND 2 REQUEST FOR ADDITIONAL INFORMATION REGARDING CALCULATED PEAK CONTAINMENT INTERNAL PRESSURE LICENSE AMENDMENT (TAC NOS. ME9081 AND ME9082)
Dear Mr. Gellrich:
By letter dated July 2, 2012, as supplemented by letter dated March 6, 2013, Calvert Cliffs Nuclear Power Plant, LLC submitted a license amendment request to revise the calculated peak containment internal pressure for the design basis loss-of-coolant accident in Technical Specification (TS) 5.5.16, "Containment Leakage Rate Testing Program" and the initial internal containment pressure limit in TS 3.6.4, "Containment Pressure" for Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2.
The Nuclear Regulatory Commission (NRC) staff is reviewing the submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). The NRC staff is requesting a response to the RAI within 30 days of the date of this letter.
If you have any questions regarding this issue, please contact me at (301) 415-1016.
Sincerely,
!raJ Nadiyah S. Morgan, Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-317 and 50-318
Enclosure:
RAI cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC RidsNrrDorlLpl1-1 RidsNrrPMCalvertCliffs LPL1-1 R/F RidsNrrLAKGoldstein RidsAcrsAcnw_MailCTR RidsNrrDorlDpr RidsRgn1 MailCenter BLee, NRR RidsOGCMailCenter RidsNrrDeEeeb MMcConnell, NRR ADAMS Accession No.: ML13114A182
- See memo dated April 9, 2013 OFFICE LPLI-1/PM LPLI-1/LA DE/EEEB/BC LPLI-1/BC NAME NMorgan KGoldstein (SRoher for)
RMathew SMeighan (A) (DPickett for)
DATE 4/25/13 4/25/13 4/912013*
4/25/13 OFFICIAL RECORD COpy