Exelkn.

Nuclear Three Mile Island Unit 1 Telephone 717-948-8000 Route 441 South, P.O. Box 480 Middletown, PA 17057 TMI-13-034 February 26, 2013 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 THREE MILE ISLAND UNIT 1 (TMI-1)

RENEWED OPERATING LICENSE NO. DPR-50 DOCKET NO. 50-289

SUBJECT:

2012 ANNUAL REPORT Attached is the 2012 Annual Report for TMI-1. This report is being submitted in accordance with TMI-1 Technical Specifications Sections 6.9.1.B.2 through 6.9.1.B.5 and 6.17. The attachments to this letter contain the following information:

Attachment 1 - Aircraft movement data from the Harrisburg International Airport (per TMI-1 T.S. section 6.9.1 .B.2).

Attachment 2 - Leak reduction program test information (per TMI-1 T.S.

6.9.1.B.3).

Attachment 3 - Pressurizer power operated relief valve and pressurizer safety valve challenges (per TMI-1 T.S. section 6.9.1 .B.4).

Attachment 4 - Results of specific activity analysis - primary coolant system (per TMI-1 T.S. section 6.9.1.B.5).

Attachment 5 - Major changes to radioactive waste treatment systems (per TMI-1 T.S. section 6.17)

Sincerely, Mar Newcomer Plant Manager, Three Mile Island Unit 1 MN/mdf Attachments cc: TMI, Unit 1 Senior Resident Inspector Administrator, Region I TMI, Unit 1 Project Manager

TMI-13-034 Attachment 1 ATTACHMENT 1 AIRCRAFT MOVEMENTS AT THE HARRISBURG INTERNATIONAL AIRPORT (HIA)

JANUARY 1, 2012 THROUGH DECEMBER 31, 2012

1. Total Aircraft Movements - 56,405
2. Estimated total number of movements of aircraft larger than 200,000 pounds -

1306.

This estimate is composed of two parts, 1056 movements of civilian aircraft, and 250 movements of U.S. Government and military aircraft.

ATTACHMENT 2 TMI-13-034 TECHNICAL SPECIFICATION 6.9.1 .B.3 PERIODIC LEAK REDUCTION PROGRAM TEST RESULTS The results of the TMI-1 2012 periodic Leak Reduction Program Tests, which included visual inspections, are summarized in Table 1.

These tests were performed in accordance with the surveillance procedures listed.

TABLE 1 2012 LEAK REDUCTION PROGRAM TEST RESULTS FOR TMI-1 LEAK LEAK SURVEILLANCE DATE OF LEAKING RATE RATE RESULTING PROCEDURES PROCEDURE TITLE / DESCRIPTION PERFORMA COMPONENT MAINTENANCE NCE I.D. AS-FOUND AS-LEFT UNDERTAKEN OP-TM-211-251 Leakage Exam inside MU tank room 02/25/2012 None 0 0 OP-TM-211-251 Leakage Exam of MU-P-1C 08/14/2012 None 0 0 OP-TM-212-251 DH Leakage Exam (Train B) 10/15/2012 None 0 0 OP-TM-211-251 Leakage Exam of MU System (Outside

RB) ml/min ml/min evaluated as acceptable OP-TM-211-250 Leak Check of Bleed Line Piping/alves 12/09/2012 None 0 0 The following are Local Leak Rate Tests with units of standard cubic centimeters per minute (sccm) 1303-11.17A Local Leak Rate Testing - Reactor 03/10/2012 Equipment 4,365 4,365 None - LLRT summation Building Equipment Hatch Airlock Hatch Airlock evaluated as acceptable OP-TM-823-251 Local Leak Rate Testing - Purge 06/12/2012 AH-V-1A/B 571 407 AH-V-1B valve & operator Exhaust Penetration Valves (combined) preventative maintenance MA-TM-244-218A Penetration 104, 105, 106, 213 and 214 08/31/2012 Penetration 104 Not 20 Flange removed for use LLRT I flange required during forced outage Note: Local Leak Rate Testing is performed under the Option B provisions of 10CFR50 Appendix J, and the minimum LLRT leakage value used is 20 sccm based on the low end of the calibration range of the flow instrumentation.

TMI-13-034 Attachment 3 ATTACHMENT 3 PRESSURIZER POWER OPERATED RELIEF VALVE AND PRESSURIZER SAFETY VALVE CHALLENGES IN 2012 There were no challenges to the pressurizer power operated relief valve (PORV) or either of the two pressurizer (PZR) safety valves during the entire calendar year of 2012.

A review of the Reactor Coolant System (RCS) pressure indication trend data concluded that the RCS pressure operated well below the PORV set point of 2450 psig, and both PZR safety valve set points of 2500 psig throughout the calendar year of 2012. Therefore no challenges to the PORV or PZR safety valves occurred during 2012.

TMI-13-034 Attachment 4 ATTACHMENT 4 RESULTS OF SPECIFIC ACTIVITY ANALYSIS-PRIMARY COOLANT SYSTEM Technical Specification 6.9.1 .B.5 requires annual reporting of certain information regarding the results of specific activity analyses in which the primary coolant exceeded the limits of Technical Specification (TS) 3.1.4.1. The limits of TS 3.1.4.1 were not exceeded at TMI-1 at any time during the year 2012. The figure of RCS activity for 2012 shows that the limit of 0.35 microcurie/gram dose equivalent 1-131 (DEI) was not exceeded in 2012.

TMI-1 Dose Equivalent Iodine (DE) in 2012 1.OOE+00 1.OOE-01 91.OOE-02 -+DEI

--TS Limit 1.OOE-03 1.OOE-04 I ';. ,.. I, I, 4-Jan 30-Jan 25-Feb 22-Mar 17-Apr 13-May 8-Jun 4-Jul 30-Jul 25-Aug 20-Sep 16-Oct 11-Nov 7-Dec Date

TMI-1 3-034 Attachment 5 ATTACHMENT 5 MAJOR CHANGES TO RAD WASTE TREATMENT SYSTEMS Technical Specification Section 6.17 requires reporting of Major changes to Radioactive Waste Treatment Systems. Major changes are interpreted to mean changes that would alter how the system functions or changes that would affect operational exposures, offsite dose rates or integrated doses. There were no major changes to the liquid, gaseous, or solid radioactive waste treatment systems at TMI-1 during the year of 2012.