November 19, 2012 TO: TECHNICAL SPECIFICATION DISTRIBUTION
- Attached are TS Bases pages associated with TSCR-139 which revises TS Bases page B3.5.1-14 to include a statement that, "Manual realignment of the RHR cross tie valves (M02010 and V-19-48) may only be credited when the valves are soft seated per normal operating procedure in order to prevent inoperability due to thermal binding."
Please update your copy of the Technical Specifications as indicated in the attached Update Instructions.
THIS CHANGE BECOMES EFFECTIVE 11/19/2012.
IMPORTANT:
Holders of Technical Specification Copies are required to sign and date the Notice of Receipt Form below, detach it at the dotted line and:
RETURN IT TO THE ADDRESSEE ALONG WITH THE SHEETS REMOVED FROM THE TECHNICAL SPECIFICATIONS.
Tom Byrne Acting Regulatory Affairs Manager 0
Copy No: 14 NRC REGION III Issued To: REGIONAL LIBRARY NOTICE OF RECEIPT OF TECHNICAL SPECIFICATION REVISION To:
Pat Vandersee, Licensing Department Duane Arnold Energy Center, 3277 DAEC Road, Palo, IA 52324 This acknowledges receipt of TSCR-1 39 to the Duane Arnold Energy Center Technical Specifications.
Signature:
DATE
November 19, 2012 Page 1 of 1 DUANE ARNOLD ENERGY CENTER TECHNICAL SPECIFICATIONS UPDATE INSTRUCTIONS REMOVE INSERT TS BASES VOL 1:
List of Effective Pages 1-5 TS BASES VOL 1:
List of Effective TS BASES VOL 2:
B 3.5-14 Pages 1-5 TS BASES VOL 2:
B 3.5-14
Page 1 of 5 LIST OF EFFECTIVE PAGES Appendix A to DPR-49 Technical Specifications Bases Revision Date 11/19/12 Page Date Rev.
Pane Date Rev.
Page Date Rev.
B 2.0-1 08/01/98 223 B 3.1-18 08/01/98 223 B 3.3-7 11/07/01 044 B 2.0-2 08/01/98 223 B 3.1-19 ' 08/01/98 223 B 3.3-8 11/07/01 044 B 2.0-3 11/07/01 044 B 3.1-20 04/27/12 120 B 3.3-9 08/01/98 223 B 2.0-4 08/01/98 223 B 3.1-21 04/27/12 120 B 3.3-10 05/31/02 057 B 2.0-5 04/09/04 044A B 3.1-22 11/20/08 098 B 3.3-11 08/01/98 223 B 2.0-6 04/09/04 044A B 3.1-23 08/01/98 223 B 3.3-12 08/01/98 223 B 2.0-7 08/01/98 223 B 3.1-24 08/01/98 223 B 3.3-13 02/23/09 102 B 2.0-8 04/09/04 044A B 3.1-25 ii/20/08 098 B 3.3-14 04/18/08 100 B 2.0-9 04/09/04 044A B 3.1-26 08/01/98 223 B 3.3-15 08/01/98 223 B 3.0-1 04/29/11 122 B 3.1-27 04/09/04 044A B 3.3-16 08/01/98 223 B 3.0-2 10/30/00 026A B 3.1-28 08/01/98 223 B 3.3-17 08/01/98 223 B 3.0-3 08/01/98 223 B 3.1-29 08/01/98 223 B 3.3-18 08/25/10 123 B 3.0-4 08/01/98 223 B 3.1-30 08/01/98 223 B 3.3-19 11/07/01 044 B 3.0-5 04/18/05 064 B 3.1-31 08/01/98 223 B 3.3-20 08/25/10 123 B 3.0-6 04/18/05 064 B 3.1-32 04/27/12 120 B 3.3-21 08/01/98 223 B 3.0-7 04/18/05 064 B 3.1-33 04/09/04 044A B 3.3-22 08/01/98 223 B 3.0-8 04/18/05 064 B 3.1-34 08/01/98 223 B 3.3-23 08/01/98 223 B 3.0-9 04/18/05 064 B 3.1-35 04/18/08 093 B 3.3-24 08/01/98 223 B 3.0-10 04/18/05 064 B 3.1-36 03/25/05 070 B 3.3-25 08/01/98 223 B 3.0-11 04/18/05 064 B 3.1-37 03/25/05 070 B 3.3-26 04/27/12 120 B 3.0-12 04/18/05 029 B 3.1-38 04/27/12 120 B 3.3-27 04/27/12 120 B 3.0-13 06/12/07 079 B 3.1-39 04/11/01 236 B 3.3-28 04/27/12 120 B 3.0-13A 04/29/11 122 B 3.1-40 08/01/98 223 B 3.3-29 04/27/12 120 B 3.0-13B 04/29/11 122 B 3.141 08/01/98 223 B 3.3-30 04/27/12 120 B 3.0-13C 04/29/11 122 B 3.142 04/27/12 120 B 3.3-31 04/12/12 120 B 3.0-13D 04/29/11 122 B 3.1-43 04/27/12 120 B 3.3-32 04/27/12 120 B 3.0-14 07/11/05 029 B 3.1-44 04/27/12 120 B 3.3-33 04/27/12 120 B 3.0-15 07/11/05 029 B 3.1-45 04/09/04 044A B 3.3-34 04/27/12 120 B 3.0-16 07/11/05 029 B 3.1-46 09/20/05 044A B 3.3-35 04/27/12 120 B 3.0-17 07/11/05 029 B 3.1-47 09/20/05 223 B 3.3-36 04/09/04 044A B 3.0-18 07/11/05 029 B 3.1-48 04/27/12 120 B 3.3-37 08/01/98 223 B 3.0-19 07/11/05 029 B 3.1-49 04/27/12 120 B 3.3-38 08/01/98 223 B 3.1-1 08/01/98 223 B 3.2-1 04/09/04 044A B 3.3-39 08/01/98 223 B 3.1-2 08/01/98 223 B 3.2-2 02/23/09 115 B 3.3-40 08/01/98 223 B 3.1-3 08/01/98 223 B 3.2-3 04/09/04 044A B 3.3-41 08/01/98 223 B 3.1-4 08/01/98 223 B 3.2-4 04/27/12 120 B 3.342 04/27/12 120 B 3.1-5 08/01/98 223 B 3.2-5 04/09/04 044A B 3.343 04/27/12 120 B 3.1-6 08/01/98 223 B 3.2-6 04/09/04 044A B 3.3-44 04/27/12 120 B 3.1-7 04/09/04 044A B 3.2-7 04/09/04 044A B 3.345 04/27/12 120 B 3.1-8 04/09/04 044A B 3.2-8 04/09/04 044A B 3.3-46 08/01/98 223 B 3.1-9 08/01/98 223 B 3.2-9 11/07/01 044 B 3.3-47 08/01/98 223 B 3.1-10 08/01/98 223 B 3.2-10 04/27/12 120 B 3.3-48 08/01/98 223 B 3.1-11 08/01/98 223 B 3.2-11 04/09/04 044A B 3.3-49 04/18/08 093 B 3.1-12 08/01/98 223 B 3.3-1 08/01/98 223 B 3.3-50 03/25/05 070 B 3.1-13 04/09/04 044A B 3.3-2 08/01/98 223 B 3.3-51 03/25/05 070 B 3.1-14 08/01/98 223 B 3.3-3 04/09/04 044A B 3.3-52 03/25/05 070 B 3.1-15 08/01/98 223 B 3.3-4 08/01/98 223 B 3.3-53 03/25/05 070 B 3.1-16 08/01/98 223 B 3.3-5 08/01/98 223 B 3.3-54 04/27/12 120 B 3.1-17 11/20/08 098 B 3.3-6 08/01/98 223 B 3.3-55 04/27/12 120
Page 2 of 5 LIST OF EFFECTIVE PAGES Appendix A to DPR-49 Technical Specifications Bases Revision Date 11/19/12 Page Date Rev.
Page Date Rev.
Page Date Rev.
B 3.3-56 04/27/12 120 B 3.3-104 08/01/98 223 B 3.3-153 08/01/98 223 B 3.3-57 04/27/12 120 B 3.3-105 08/01/98 223 B 3.3-154 08/01/98 223 B 3.3-57A 04/18/08 093 B 3.3-106 04/09/04 044A B 3.3-155 08/01/98 223 B 3.3-58 07/06/04 067A B 3.3-107 04/09/04 044A B 3.3-156 08/01/98 223 B 3.3-59 07/06/04 067A B 3.3-108 04/09/04 044A B 3.3-157 08/01/98 223 B 3.3-60 10/20/03 065 B 3.3-109 08/01/98 223 B 3.3-158 04/09/04 044A B3.3-61 10/20/03 065 B3.3-110 10/05/12 283 B3.3-159 04/09/04 044A B3.3-62 10/20/03 065 B3.3-111 08/01/98 223 B3.3-160 08/01/98 223 B3.3-63 09/11/06 088 B3.3-112 08/01/98 223 B3.3-161 02/09/07 074A B 3.3-64 04/18/05 064 B 3.3-113 08/01/98 223 B 3.3-162 02/09/07 074A B 3.3-65 04/18/05 064 B 3.3-114 08/01/98 223 B 3.3-163 04/09/04 044A B 3.3-66 07/06/04 067A B 3.3-115 08/01/98 223 B 3.3-164 08/01/98 223 B 3.3-67 04/27/12 120 B 3.3-116 08/01/98 223 B 3.3-165 08/01/98 223 B 3.3-68 04/27/12 120 B 3.3-117 04/09/04 044A B 3.3-166 08/01/98 223 B3.3-69 07/06/04 067A B3.3-118 08/01/98 223 B3.3-167 08/01/98 223 B 3.3-70 08/01/98 223 B 3.3-119 08/01/98 223 B 3.3-168 04/09/04 044A B 3.3-71 08/01/98 223 B 3.3-120 04/09/04 044A B 3.3-169 08/01/98 223 B3.3-72 04/18/05 064 B3.3-121 08/01/98 223 B3.3-170 06/29/00 003 B 3.3-73 04/27/12 120 B 3.3-122 08/01/98 223 B 3.3-171 06/29/00 003 B 3.3-74 04/27/12 120 B 3.3-123 08/01/98 223 B 3.3-172 06/29/00 003 B 3.3-75 08/01/98 223 B 3.3-124 08/01/98 223 B 3.3-173 06/29/00 003 B 3.3-76 08/01/98 223 B 3.3-125 08/01/98 223 B 3.3-174 06/29/00 003 B 3.3-77 08/01/98 223 B 3.3-126 08/01/98 223 B 3.3-175 06/29/00 003 B 3.3-78 11/07/01 044 B 3.3-127 08/01/98 223 B 3.3-176 06/29/00 003 B 3.3-79 08/01/98 223 B 3.3-128 08/01/98 223 B 3.3-177 06/29/00 003 B 3.3-80 08/25/10 123 B 3.3-129 08/01/98 223 B 3.3-178 06/29/00 003 B 3.3-81 08/25/10 123 B 3.3-130 08/01/98 223 B 3.3-179 06/29/00 003 B3.3-82 11/07/01 044 B3.3-131 08/01/98 223 B3.3-180 06/29/00 003 B 3.3-83 08/01/98 223 B 3.3-132 08/01/98 223 B 3.3-181 06/29/00 003 B 3.3-84 04/27/12 120 B 3.3-133 08/01/98 223 B 3.3-182 06/29/00 003 B 3.3-85 04/27/12 120 B 3.3-134 08/01/98 223 B 3.3-183 06/29/00 003 B 3.3-86 04/27/12 120 B 3.3-135 08/01/98 223 B 3.3-184 06/29/00 003 B 3.3-87 04/09/04 044A B 3.3-136 08/01/98 223 B 3.3-185 02/09/07 074A B 3.3-88 08/01/98 223 B 3.3-137 04/27/12 120 B 3.3-186 04/27/12 120 B 3.3-89 11/02/98 005 B 3.3-138 04/27/12 120 B 3.3-187 04/27/12 120 B 3.3-90 08/01/98 223 B 3.3-139 04/27/12 120 B 3.3-188 04/27/12 120 B 3.3-91 08/01/98 223 B 3.3-140 08/01/98 223 B 3.3-189 06/29/00 003 B3.3-92 08/01/98 223 B3.3-141 08/01/98 223 B 3.3-190 08/01/98 223 B3.3-93 08/01/98 223 B3.3-142 11/07/01 044 B3.3-191 08/01/98 223 B 3.3-94 04/27/12 120 B 3.3-143 11/07/01 044 B 3.3-192 08/01/98 223 B 3.3-95 04/27/12 120 B 3.3-144 08/01/98 223 B 3.3-193 08/01/98 223 B 3.3-96 08/01/98 223 B 3.3-145 08/01/98 223 B 3.3-194 05/16/01 037 B 3.3-97 08/01/98 223 B 3.3-146 08/01/98 223 B 3.3-195 05/16/01 037 B 3.3-98 08/18/06 084 B 3.3-147 08/01/98 223 B 3.3-196 08/01/98 223 B 3.3-99 08/01/98 223 B 3.3-148 04/27/12 120 B 3.3-197 08/01/98 223 B 3.3-100 04/09/04 044A B 3.3-149 04/27/12 120 B 3.3-198 04/27/12 120 B 33-101 08/18/06 084 B 3.3-150 04/27/12 120 B 3.3-199 04/27/12 120 B 33-102 08/01/98 223 B 3.3-151 02/09/07 074A B 3.3-200 04/27/12 120 B3,3-103 08/01/98 223 B3.3-152 08/01/98 223 B3.3-201 08/01/98 223
Page 3 of 5 LIST OF EFFECTIVE PAGES Appendix A to DPR-49 Technical Specifications Bases Revision Date 11/19/12 Paie Date Rev.
Page Date Rev.
Paae Date Rev.
B 3.3-202 08/01/98 223 B 3.3-203 04/09/04 044A B 3.3-204 08/01/98 223 B 3.3-205 04/18/05 064 B 3.3-206 08/01/98 223 B 3.3-207 04/27/12 120 B 3.3-208 04/27/12 120 B 3.3-209 04/09/04 044A B 3.3-210 04/09/04 044A B 3.3-211 08/01/98 223 B 3.3-212 04/27/12 120 B 3.3-213 04/27/12 120 B 3.3-214 04/27/12 120 B 3.3-215 11/02/98 005 B 3.3-216 11/02/98 005 B 3.3-217 08/01/98 223 B 3.3-218 08/01/98 223 B 3.3-219 08/01/98 223 B 3.3-220 08/01/98 223 B 3.3-221 10/20/03 066 B 3.3-222 04/27/12 120 B 3.3-223 04/27/12 120 B 3.3-224 08/01/98 223 B 3.3-225 08/01/98 223 B 3.3-226 08/01/98 223 B 3.3-227 08/01/98 223 B 3.3-228 08/01/98 026A B 3.3-229 04/27/12 120 B 3.3-230 04/27/12 120 B 3.4-1 08/01/98 223 B 3.4-2 08/01/98 223 B 3.4-3 11/07/01 044 B 3.4-4 11/07/01 044 B 3.4-5 08/01/98 223 B 3.4-6 08/01/98 223 B 3.4-7 08/01/98 223 B 3.4-8 04/27/12 120 B 3.4-9 04/09/04 044A B 3.4-10 08/01/98 223 B 3.4-11 08/01/98 223 B 3.4-12 08/01/98 223 B 3.4-13 04/27/12 120 B 3.4-14 04/09/04 044A B 3.4-15 08/01/98 223 B 3.4-16 11/07/01 044 B 3.4-17 08/01/98 223 B 3.4-18 08/01/98 223 B 3.4-19 09/26/12 129 B 3.4-20 09/26/12 129 B 3.4-21 B 3.4-22 B 3.4-23 B 3.4-24 B 3.4-25 B 3.4-26 B 3.4-27 B 3.4-28 B 3.4-29 B 3.4-30 B 3.4-31 B 3.4-32 08/01/98 223 08/01/98 223 08/01/98 223 08/01/98 223 04/27/12 120 08/01/98 223 04/30/99 005 05/16/01 045 05/16/01 045 05/16/01 045 04/18/05 064 04/27/12 120 B.3.4-32a 04/27/12 120 B 3.4-33 B 3.4-34 B 3.4-35 B 3.4-36 B 3.4-37 B 3.4-38 B 3.4-39 B 3.4-40 B 3.4-41 B 3.4-42 B 3.443 B 3.4-44 B 3.445 B 3.4-46 B 3.4-47 B 3.4-48 B 3.449 B 3.4-50 B 3.4-51 B 3.4-52 B 3.4-53 B 3.4-54 B 3.4-55 B 3.4-56 B 3.4-57 B 3.4-58 B 3.4-59 B 3.4-60 B 3.4-61 B 3.5-1 B 3.5-2 B 3.5-3 B 3.5-4 B 3.5-5 B 3.5-6 B 3.5-7 04/09/04 044A 08/20/01 037 04/18/05 064 04/27/12 120 08/01/98 223 10/30/00 026A 04/18/05 064 08/01/98 223 04/27/12 120 08/01/98 223 08/01/98 223 10/30/00 026A 08/01/98 223 08/01/98 223 04/27/12 120 08/01/98 223 08/01/98 223 08/01/98 223 04/30/99 017 04/30/99 017 04/30/99 017 04/27/12 120 04/30/99 017 04/27/12 120 04/27/12 120 04/09/04 044A 10/26/07 097 04/27/12 120 10/26/07 097 08/01/98 223 08/01/98 223 08/01/98 223 10/10/08 112 10/10/08 112 10/10/08 112 04/18/05 064 B 3.5-8 B 3.5-9 B 3.5-10 B 3.5-11 B 3.5-12 B 3.5-13 B 3.5-14 B 3.5-15 B 3.5-16 B 3.5-17 B 3.5-18 B 3.5-19 B 3.5-20 B 3.5-21 B 3.5-22 B 3.5-23 B 3.5-24 B 3.5-25 B 3.5-26 B 3.5-27 B 3.5-28 B 3.5-29 B 3.5-30 B 3.5-31 B 3.5-32 B 3.5-33 B 3.6-1 B 3.6-2 B 3.6-3 B 3.6-4 B 3.6-5 B 3.6-6 B 3.6-7 B 3.6-8 B 3.6-9 B 3.6-10 B 3.6-11 B 3.6-12 B 3.6-13 B 3.6-14 B 3.6-15 B 3.6-16 B 3.6-17 B 3.6-18 B 3.6-19 B 3.6-20 B 3.6-21 B 3.6-22 B 3.6-23 08/01/98 223 08/01/98 223 08/01/98 223 08/01/98 223 11/07/01 044 04/27/12 120 11/19/12 139 04/27/12 120 04/27/12 120 04/27/12 120 09/26/12 129 09/26/12 129 04/09/04 044A 08/01/98 223 10/05/12 283 08/01/98 223 08/01/98 223 10/05/12 283 04/27/12 120 08/01/98 223 04/09/04 044A 04/18/05 064 04/27/12 120 04/27/12 120 04/27/12 120 04/27/12 223 08/01/98 223 08/01/98 223 04/09/04 044A 08/01/98 223 04/27/12 120 08/01/98 223 11/07/01 044 08/01/98 223 08/01/98 223 08/01/98 223 08/01/98 223 08/01/98 223 04/27/12 120 9/30/10 104 02/09/07 074A 9/30/10 104 9/30/10 104 09/30/10 104 07/02/99 006 09/30/10 104 09/30/10 104 09/30/10 104 09/30/10 104
Page 4 of 5 LIST OF EFFECTIVE PAGES Appendix A to DPR-49 Technical Specifications Bases Revision Date 11/19/12 Page Date Rev.
Page Date Rev.
Page Date Rev.
B 3.6-24 B 3.6-25 B 3.6-26 B 3.6-27 B 3.6-28 B 3.6-29 B 3.6-30 B 3.6-31 B 3.6-32 B 3.6-33 B 3.6-34 B 3.6-35 B 3.6-36 B 3.6-37 B 3.6-38 B 3.6-39 B 3.6-40 B 3.6-41 B 3.6-42 B 3.6-43 B 3.6-44 B 3.6-45 B 3.6-46 B 3.6-47 B 3.6-48 B 3.6-49 B 3.6-50 B 3.6-51 B 3.6-52 B 3.6-53 B 3.6-54 B 3.6-55 B 3.6-56 B 3.6-57 B 3.6-58 B 3.6-59 B 3.6-60 B 3.6-61 B 3.6-62 B 3.6-63 B 3.6-64 B 3.6-65 B 3.6-66 B 3.6-67 B 3.6-68 B 3.6-69 B 3.6-70 B 3.6-71 B 3.6-72 09/30/10 104 09/30/10 104 04/27/12 120 04/27/12 120 04/27/12 120 4/16/10 096A 11/07/01 044 08/01/98 223 04/27/12 120 08/01/98 223 08/01/98 223 09/26/12 129 09/26/12 129 08/01/98 223 08/01/98 223 08/01/98 223 08/01/98 223 08/01/98 223 04/27/12 120 08/01/98 223 04/09/04 044A 08/01/98 223 08/01/98 223 04/27/12 120 04/27/12 120 08/01/98 044A 11/07/01 223 11/02/98 005 08/01/98 223 04/27/12 120 04/09/04 044A 08/01/98 223 08/01/98 223 04/27/12 120 08/01/98 223 11/07/01 044 11/07/01 044 08/01/98 223 08/01/98 223 04/27/12 120 04/09/04 044A 10/20/99 018 10/20/99 018 08/01/98 223 04/27/12 120 07/27/07 083A Deleted Deleted Deleted B 3.6-73 B 3.6-74 B 3.6-75 B 3.6-76 B 3.6-77 B 3.6-78 B 3.6-79 B 3.6-80 B 3.6-81 B 3.6-82 B 3.6-83 B 3.6-84 B 3.6-85 B 3.6-86 B 3.6-87 B 3.6-88 B 3.6-89 B 3.6-90 B 3.6-91 B 3.6-92 B 3.6-93 B 3.6-94 B 3.6-95 B 3.6-96 B 3.7-1 B 3.7-2 B 3.7-3 B 3.7-4 B 3.7-5 B 3.7-6 B 3.7-7 B 3.7-8 B 3.7-9 B 3.7-10 B 3.7-11 B 3.7-12 B 3.7-13 B 3.7-14 B 3.7-15 B 3.7-16 B 3.7-17 B 3.7-18 B 3.7-19 B 3.7-20 B 3.7-21 B 3.7-22 B 3.7-23 B 3.7-24 Deleted 07/27/07 083A 07/27/07 083A 04/27/12 120 07/27/07 083A 05/16/01 037 05/16/01 037, 05/16/01 037 04/27/12 120 04/09/04 044A 09/30/10 104 09/30/10 104 05/16/01 037 09/30/10 104 09/30/10 104 04/27/12 120 04/27/12 120 04/09/04 044A 08/20/01 037 05/16/01 223 05/16/01 037 04/27/12 120 04/27/12 120 04/09/04 044A 04/09/04 044A 04/09/04 044A 08/01/98 044A 04/18/05 064 08/01/98 223 04/27/12 120 04/02/09 095 04/02/09 095 04/02/09 095 04/27/12 120 04/27/12 120 04/27/12 120 04/09/04 044A 05/27/11 127 08/01/98 223 08/01/98 223 04/27/12 120 12/18/08 092 12/18/08 092 12/18/08 092 12/18/08 092 12/18/08 092 12/18/08 092 12/18/08 092 B 3.7-24B 04/27/12 120 B 3.7-24C 04/27/12 120 B 3.7-25 12/18/08 223 B 3.7-26 12/18/08 223 B 3.7-27 12/18/08 113 B 3.7-28 01/18/08 068 B 3.7-29 04/27/12 120 B 3.7-30 04/09/04 044A B 3.7-31 08/01/98 223 B 3.7-32 04/27/12 120 B 3.7-33 08/25/10 123 B 3.7-34 02/23/09 115 B 3.7-35 04/27/12 120 B 3.7-36 04/27/12 120 B 3.7-37 04/09/04 044A B 3.7-38 04/27/12 120 B 3.7-39 04/09/04 044A B 3.7-40 04/09/04 044A B 3.7-41 07/02/99 006 B 3.7-42 07/02/99 006 B 3.7-43 07/02/99 006 B 3.7-44 04/27/12 120 B 3.8-1 04/09/04 044A B 3.8-2 10/10/08 111 B 3.8-3 04/09/04 044A B 3.8-4 06/09/06 082 B 3.8-5 06/09/06 082 B 3.8-6 06/09/06 082 B 3.8-7 08/01/98 223 B 3.8-8 09/26/08 1O0A B 3.8-9 09/26/08 lOlA B 3.8-10 09/26/08 101A B 3.8-11 09/26/08 101A B 3.8-12 09/26/08 lOlA B 3.8-13 09/26/08 lOlA B 3.8-14 09/26/08 101A B 3.8-15 04/27/12 120 B 3.8-16 04/27/12 120 B 3.8-17 04/27/12 120 B 3.8-18 04/27/12 120 B 3.8-19 04/27/12 120 B 3.8-20 04/27/12 120 B 3.8-21 04/27/12 120 B 3.8-22 04/27/12 120 B 3.8-23 04/09/04 044A B 3.8-24 04/27/12 120 B 3.8-25 06/09/06 082 B 3.8-26 08/01/98 223 B 3.8-27 08/01/98 223 B 3.7-24A 04/27/12 120
Page 5 of 5 LIST OF EFFECTIVE PAGES Appendix A to DPR-49 Technical Specifications Bases Revision Date 11/19/12 Paze Date Rev.
Pane Date Rev.
Paee Date Rev.
B 3.8-28 B 3.8-29 B 3.8-30 B 3.8-31 B 3.8-32 B 3.8-33 B 3.8-34 B 3.8-ý35 B 3.8-36 B 3.8-37 B 3.8-38 B 3.8-39 B 3.8-40 B 3;8-41 B 3.8-42 B 3.8-43 B 3.8-44 B 3.8-45 B 3.8-46 B 3.8-47 B 3.8-48 B 3.8-49 B 3.8-50 B 3.8-51 B 3.8-52 B 3.8-53 B 3.8-54 B 3.8-55 B 3.8-56 B 3.8-57 B 3.8-58 B 3.8-59 B 3.8-60 B 3.8-61 B 3.8-62 B 3.8-63 B 3.8-64 B 3.8-65 B 3.8-66 B 3.8-67 B 3.8-68 B 3.8-69 B 3.8-70 B 3.8-71 B 3.8-72 B 3.8-73 B 3.8-74 B 3.8-75 B 3.8-76 08/01/98 08/01/98 10/30/00 10/30/00 08/18/06 08/18/06 08/01/98 10/27/06 08/01/98 04/27/12 08/01/98 04/27/12 04/27/12 08/01/98 06/02/09 04/09/04 08/01/98 11/22/02 11/22/02 04/27/12 04/27/12 04/27/12 01/24/03 04/27/12 04/09/04 08/01/98 08/01/98 04/09/04 04/09/04 06/12/09 06/12/09 04/27/12 08/01/98 08/01/98 04/09/04 04/09/04 11/02/98 08/01/98 08/01/98 08/01/98 08/01/98 08/01/98 11/02/98 04/27/12 04/27/12 08/01/98 04/09/04 08/01/98 11/02/98 223 223 026A 026A 085 085 223 086 223 120 223 120 120 223 118 044A 223 048 048 120 120 120 060 120 044A 223 223 044A 044A 118 118 120 223 223 044A 044A 005 223 223 223 223 223 005 120 120 223 044A 223 005 B 3.8-77 B 3.8-78 B 3.9-1 B 3.9-2 B 3.9-3 B 3.9-4 B 3.9-5 B 3.9-6 B 3.9-7 B 3.9-8 B 3.9-9 B 3.9-10 B 3.9-11 B 3.9-12 B 3.9-13 B 3.9-14 B 3.9-15 B 3.9-16 B 3.9-17 B 3.9-18 B 3.9-19 B 3.9-20 B 3.9-21 B 3.9-22 B 3.9-23 B 3.9-24 B 3.9-25 B 3.9-26 B 3.9-27 B 3.9-28 B 3.9-29 B 3.9-30 B 3.9-31 B 3.10-1 B 3.10-2 B 3.10-3 B 3.10-4 B 3.10-5 B 3.10-5A B 3.10-6 B 3.10-7 B 3.10-8 B 3.10-9 B 3.10-10 B 3.10-11 B 3.10-12 B 3.10-13 B 3.10-14 B 3.10-15 11/02/98 04/27/12 08/01/98 08/01/98 08/01/98 04/27/12 08/01/98 08/01/98 04/27/12 04/27/12 08/01/98 04/27/12 04/09/04 08/01/98 08/01/98 08/01/98 04/09/04 08/01/98 08/01/98 04/27/12 04/09/04 08/01/98 04/27/12 08/01/98 10/30/00 06/12/09 03/17/99 04/27/12 08/01/98 10/30/00 03/17/99 08/01/98 04/27/12 02/16/07 02/16/07 02/16/07 02/16/07 02/16/07 02/16/07 08/01/98 08/01/98 08/01/98 08/01/98 04/27/12 08/01/98 08/01/98 08/01/98 08/01/98 04/27/12 005 120 223 223 223 120 223 223 120 120 223 120 044A 223 223
- 223, 044A 223 223 120 044A 223 120 223 223 117 019 120 223 026A 019 223 120 078 078 078 078 078 078 223 223 223 223 120 223 223 223 223 120 B 3.10-16 08/01/98 B 3.10-17 08/01/98 B 3.10-18 08/01/98 B 3.10-19 08/01/98 B 3.10-20 04/27/12 B 3.10-21 08/01/98 B 3.10-22 08/01/98 B 3.10-23 08/01/98 B 3.10-24 08/01/98 B 3.10-25 04/27/12 B 3.10-26 08/01/98 B 3.10-27 08/01/98 B 3.10-28 04/27/12 B 3.10-29 08/01/98 B 3.10-30 08/01/98 B 3.10-31 08/01/98 B 3.10-32 08/01/98 B 3.10-33 08/01/98 B 3.10-34 08/01/98 B 3.10-35 08/01/98 B 3.10-36 08/01/98 B 3.10-37 04/27/12 B 3.10-38 04/27/12 223 223 223 223 120 223 223 223 223 120 223 223 120 223 223 223 223 223 223 223 223 120 120
ECCS -
Operating B 3.5.1 BASES SURVEILLANCE REQUIREMENTS (continued)
SR 3.5.1.2 Verifying the correct alignment for power operated and automatic valves in the ECCS flow paths provides assurance that the proper flow paths will exist for ECCS operation. This SR does not apply to valves that are locked, sealed, or otherwise secured in position since these were verified to be in the correct position prior to locking, sealing, or securing. A valve that receives an initiation signal is allowed to be in a nonaccident position provided the valve will automatically reposition in the proper stroke time. This SR does not require any testing or valve manipulation; rather, it involves verification that those valves capable of potentially being mispositioned are in the correct position. This SR does not apply to manual valves or valves that cannot be inadvertently misaligned, such as check valves. For the HPCI System, this SR also includes the steam flow path for the turbine and the flow controller position.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program. The Frequency of this SR was derived from the Inservice Testing Program requirements for performing valve testing. The Frequency is further justified because the valves are operated under procedural control and because improper valve position would only affect a single subsystem. This Frequency has been shown to be acceptable through operating experience.
In Mode 3 with reactor steam dome pressure less than the actual RHR interlock pressure, the RHR System may be required to operate in the shutdown cooling mode to remove decay heat and sensible heat from the reactor. Therefore, this SR is modified by Note 1, which allows the LPCI System to be considered OPERABLE during alignment and operation for decay heat removal, if capable of being manually realigned (remote or local) to the LPCI mode and not otherwise inoperable. Manual alignment of the RHR cross tie valves (M02010 and V-1 9-48) may only be credited when the valves are soft seated per normal operating procedure in order to prevent inoperability due to thermal binding.
Alignment and operation for decay heat removal includes when the required RHR pump is not operating or when the system is realigned from or to the RHR shutdown cooling mode. At the low pressures and decay heat loads associated with operation in Mode 3 with reactor steam dome pressure less than the RHR interlock pressure, a reduced complement of low pressure ECCS subsystems should provide the required core cooling, thereby allowing operation of RHR shutdown cooling, when necessary.
(continued)
DAEC B 3.5-14 TSCR-139