ML12356A229
| ML12356A229 | |
| Person / Time | |
|---|---|
| Site: | Waterford (NPF-038) |
| Issue date: | 12/21/2012 |
| From: | Ray Kellar Division of Reactor Safety IV |
| To: | Jacobs D Entergy Operations |
| References | |
| EA-12-198 IR-12-008 | |
| Download: ML12356A229 (2) | |
See also: IR 05000382/2012008
Text
December 21, 2012
Donna Jacobs, Site Vice President, Operations
Entergy Operations, Inc.
Waterford Steam Electric Station, Unit 3
17265 River Road
Killona, LA 70057-075
SUBJECT:
RESPONSE TO WATERFORD STEAM ELECTRIC STATION, UNIT 3, REPLY
TO NOTICE OF VIOLATION EA-12-198 IN NRC BIENNIAL PROBLEM
IDENTIFICATION AND RESOLUTION INSPECTION REPORT
Dear Ms. Jacobs:
Thank you for your letter dated December 3, 2012, in response to our November 5, 2012, letter
and Notice of Violation 05000382/2012008 (EA 12-198) concerning the failure of plant
personnel to establish a design basis to determine the river level at which flood control
measures were to be initiated for closing the water tight doors as required in
Procedure OP-901-521, Severe Weather and Flooding. We have reviewed your reply and find
it responsive to the concerns raised in our Notice of Violation. We will review the
implementation of your corrective actions during a future inspection to determine that full
compliance has been achieved and will be maintained.
Sincerely,
/RA/
Ray L. Kellar, P.E., Chief
Technical Support Branch
Division of Reactor Safety
Docket No.: 50-382
License No: NPF-38
UNITED STATES
NUCLEAR REGULATORY COMMISSION
RE G IO N I V
1600 EAST LAMAR BLVD
ARLINGTON, TEXAS 76011-4511
D. Jacobs
-2-
Electronic distribution by RIV:
Regional Administrator (Elmo.Collins@nrc.gov)
Deputy Regional Administrator (Art.Howell@nrc.gov)
DRP Director (Kriss.Kennedy@nrc.gov)
Acting DRP Deputy Director (Barry.Westreich@nrc.gov)
DRS Acting Director (Tom.Blount@nrc.gov))
DRS Acting Deputy Director (Jeff.Clark@nrc.gov)
Senior Resident Inspector, Grand Gulf (Rich.Smith@nrc.gov)
Senior Resident Inspector, Waterford 3 (Marlone.Davis@nrc.gov)
Resident Inspector, Waterford 3 (Dean.Overland@nrc.gov)
Branch Chief, DRP/E (Don.Allen@nrc.gov)
Senior Project Engineer, DRP/E (Ray.Azua@nrc.gov)
Project Engineer (Jim.Melfi@nrc.gov)
Project Engineer (Dan.Bradley@nrc.gov)
Project Engineer (Rayomand.Kumana@nrc.gov)
Reactor Inspector (Matt.Young@nrc.gov)
R4Enforcement@nrc.gov
WAT Administrative Assistant (Linda.Dufrene@nrc.gov)
Public Affairs Officer (Victor.Dricks@nrc.gov)
Public Affairs Officer (Lara.Uselding@nrc.gov)
Project Manager (Kaly.Kalyanam@nrc.gov)
Branch Chief, DRS/TSB (Ray.Kellar@nrc.gov)
RITS Coordinator (Marisa.Herrera@nrc.gov)
Regional Counsel (Karla.Fuller@nrc.gov)
Congressional Affairs Officer (Jenny.Weil@nrc.gov)
OEMail Resource
ROPreports
RIV/ETA: OEDO (Cayetano.Santos@nrc.gov)
DRS/TSB STA (Dale.Powers@nrc.gov)
DOCUMENT NAME: R:\\REACTORS\\WT3\\PI&R NOV Acknowledgment Letter
SUNSI Review
Non-Sensitive
Sensitive
Publicly Available
Non-Publicly Available
Reviewer
Initials: HAF
DRS/TSB:SRI
ACES:SEC
DRS/TSB:C
HAFreeman
RSBrowder
RLKellar
GReplogle for
/RA/
GReplogle for
12/21/12
12/18/12
12/21/12
OFFICIAL RECORD COPY