ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 1 of 6 Status: YO NE] U-]

Seismic Walkdown Checklist (SWC)

Equipment ID No. 2X41-CO1OA Equip. Classý Equipment Description DG 2C ROOM FAN 2A Location:. Bldg. DIESEL Floor El. 150 Room, Area ROOF Manufacturer, Model, Etc, (optional but recommended).

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)?

YO Ni

2. Is the anchorage free of bent, broken, missing or loose hardware?

Viewed anchorage from underside of roof slab and on the roof.

3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?
5. Is the anchorage configuration consistent with plant documentation?

(Note: This question only applies if the item is one of the 50% for which an anchorage configuration. verification is required.)

Anchorage is consistent with SEWS package dated 02/18/1994 and H-12350,. Rev. 5.

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NO UD N/ArC YZ NCI U-N/AO YN, NC, UC N/AC*

Y0 NCI U-N/AC YI NC UC Enter the.equipment class name from Appendix B,: Classes of Equipment.

Page 124 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 2 of 6 Status: YN Nn] U"]

Seismic Walkdown Checklist (SWC)

Equipment ID No. 2X41-COeA Equip. Class Equipment Description DG 2CROOM FAN 2A Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?

YZ NEI ULI N/AEl

8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE] U[- N/Al]

and masonry block walls not. likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid, damage?

1.0.. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

YU NEI UI] N/AL]

YZ NEL UEJ Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YN NEIl UL adversely affect the safety functions of the equipment?

A screw on the east side cover plate that the head has been sheared off (see photograph 4). There are three other screws supporting the plate, which is judged to be adequate to secure it in place. The damaged screw is not a seismic concern. CR 523328 has been written to replace the screw.

Comments (Additional pages may be added as necessary)

None.

Evaluated by: Juan Vizcava Date: 09/2412012 Pntrick KPIIv 09124/2012 Page 125 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2X41-CO10A Equip. Class' Equipment Description DG 2C ROOM FAN 2A NO. SNCH082-RPT-02, VERSION 1.0 Sheet 3 of 6 Status: YZ NEI UF]

Photographs 1: Equipment MPL# (2X41-COIOA)

Page 126 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 2: Equipment from Below Roof (2X41 -C010A)

Page 127 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 3: Equipment from Above Roof (2X41-COI OA)

Page 128 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 6 of 6 4: Cover Plate with Sheared Screw Head (2X41-C010A)

Page 129 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 1 of 5 Status: YZ ND-- U-Seismic Walkdown Checklist (SWC)

Equipment ID No. 2X41-CO16A Equip. Class, 9 Equipment Description BATTERY ROOM FAN Location: Bldg. DIESEL Floor El. 150 Room, Area ROOF Manufacturer, Model, Etc. (optional but recommended)

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)?

YZ NEI

2. Is the anchorage free of bent, broken, missing or loose hardware?

Bolt is replaced for housing enclosure below the roof slab as noted in SEWS package date 02/18/1994.

3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?
5. Is the anchorage configuration consistent with plant documentation?

(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Anchorage is consistent with SEWS package dated 02/18/1994 and drawing H-12349, Rev. 3.

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UD-N/AD YZ NEI U[1 N/AD YN NEI UE1 N/AD YN NEI UD N/AD[

YN NEI UE-

' Enter the equipment class name from Appendix B: Classes of Equipment.

Page 130 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

NO. SNCH082-RPT-02, VERSION 1.0 Sheet 2 of 5 Status: YE N[] U[]

Equipment ID No. 2X41-CO16A Equip. Class 1 Equipment Description BA TTERY ROOM FAN Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?

Y[9 NO Ul-N/At]

8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YI NO] Ut] N/At]

and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?
10. Based on the above seismic interaction evaluations, is equipment:free of potentially adverse seismic interaction effects?

YN NO-Ut N/At]

Y0 NEI UE-Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YE] Nt] Ut]

adversely affect the safety functions of the equipment?

Minor concrete surface cracks. from the concrete curb supporting the fan at the roofelevation. These cracks are not severe in nature and are not judged to be a seismic concern.

Comments (Additional pages may be added as necessary)

See 2X41-CO10A for AWC information, Date: 09/25/2012 Page 131 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2X41-CO16A Equip. Classi Equipment Description BA TTERY ROOM FAN NO. SNCH082-RPT-02, VERSION 1.0 Sheet 3 of 5 Status: YZ NFl U--

Photographs 1: Equipment MPL# (2X4 I-CO16A)

Page 132 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 4 of 5 2: Equipment Elevation (2X4 I-CO16A)

Page 133 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet s of s i: t~quipment rrom tielow Root t2X4i-~.U~bA)

Page 134 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 1 of 4 Status: YN NE] U-]

Seismic Walkdown Checklist (SWC)

Equipment ID No. 2E41-BO01 Equip. Class' 10 Equipment Description HPCI LUBE OIL COOLER Location: Bldg. REACTOR Floor El. 87 Room, Area HPCI Room Manufacturer, Model, Etc. (optional but recommended)

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchora2e

1. Is the anchorage configuration verification required (i.e., is the item one of 'the 50% of SWEL items requiring such verification)?

Y-I NO

2. Is the anchorage free of bent, broken, missing or loose hardware?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?
5. Is the anchorage configuration consistent with plant documentation?

(Note: This question only applies if the item is one of the 50%.for which an anchorage configuration verification is required.)

6., Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y[ NEI U-N/AE3 YU NCi U' N/AE-Y NOI U-I N/Ali YE] NI] UCI N/A0 YO NEI U--

.1 Enter the equipment class name from Appendix B: Classes of Equipment.

Page 135 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 2 of 4 Status: Yt NEI UM Seismic Walkdown Checklist (SWC)

EquipmentiD No. 2E41-Bcts Equip. Class]

Equipment Description HPCI LUBE. OIL COOLER Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?

The overhead crane was evaluated during SQUG walkdowns for the item in this room (2E41-C002) and found to be seismically adequate.

8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonryblock walls not likely to collapse onto the equipment?
9. Do~attached lines have adequate flexibility to avoid damage?
10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

YZ Nil[

U] N/AD-YI NEl U0-1 N/Al YN NEI Ur-N/ACI YZ NE-I UUI Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y[Q NEl U-I adversely affect the safety functions of the equipment?,

Comments (Additional pages may be added as necessary)

No washers are found for 2 of the 4 bolts in the anchorage. However, SWEs judged this not to be a seismic concern since the washers are not critical anchorage items when the holes are not oversized.

Area walkby was performed within the package for 2E21-COOIB.

Evaluated by: KURSAT KINALI WESLEY WILLIAMS Date: 9/24/2012 9/24/2012 Page 136 of 394

ATTACHMENT 3: SEISMIC WALKIDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2E41-BOOI Equip. Class, Equipment Description HPCI LUBE OIL COOLER NO. SNCH082-RPT-02, VERSION 1.0 Sheet 3 of 4 Status: YN N[D U[-]

Photographs Page 137 of 394

0 ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 4 of 4 Page 138 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 1 of 5 Status: YM NE] U[]

Seismic Walkdown Checklist (SWC)

Equipment.ID NO. 2T41-BOO3B Equip. Class! 10 Equipment Description RHRICS Pump Room Cooler B Location: Bldg. REACTOR Floor El. 110 Room, Area NE Diagonal Unit 2 Manufacturer, Model, Etc. (optional but recommended)

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space, below each of the following questions may be used to record the results of judgments and:

findings. Additional space is provided at the end of this checklist for documenting other comments, Anchorage

1. Is the anchorage configuration verification required. (i.e., is the ýitem one of the 50% of SWEL items requiring such verification)?

YO NO

2. Is the anchorage free of bent, broken, missing or loose hardware?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?
5. Is the anchorage configuration consistent with plant documentation?

(Note: This question only applies if the item is one of the 50%:for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YU NIl UI-- N/AE YZ NOl U.0 N/All YO NI UO N/All YIO NEl Ufi N/AI YN NO Ui Enter the equipment class name from Appendix B: Classes of Equipment.

Page 139 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 2 of 5 Status: Y[Z NEI U-1 Seismic Walkdown Checklist (SWC)

Equipment ID No. 2T41-BO03B Equip. Class' 10 Equipment Description RHRICS Pump Room Cooler B Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?
8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?
9. Do attached lines have adequate flexibility to avoid damage?
10. Based on the above seismic interaction evaluations, is equipment flee of potentially adverse seismic interaction effects?

YZ ND UD N/AD YIR NO UO N/AD Y0 ND UD N/AD YZ ND UD Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YO ND UD adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary)

There is a small section of grating broken near the corner of the 2T41-BOO3B RHR/CS Pump Room Cooler. The section of grating is extremely small and is welded to the kick plate around the pipe going through the grating at that location. The grating is not in immediate danger of separating and becoming an impact hazzard and does not affect the larger grating panel's ability to support load.

Therefore, it has been judged to be seismically adequate, See Component 2E I -BOOJIA f the Area Walk-by Checklist.

Evaluated by: John McFarland Jeff Horton Date: 09/12/2012 09/12/2012 Page 140 of 394

ATTACHMENT 3: SEISMIC WALKIDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2T41-BOO3B Equip. Class' 10 Equipment Description RHRICS Pump Room Cooler B NO. SNCH082-RPT-02, VERSION 1.0 Sheet 3 Of 5 Status: YZ NE1 UL]

Photographs Figure 1 - Equipment ID No (2T41-BO03B)

Page 141 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 4 of 5 Figure 2 - Equipment Elevation (2T41-B003B)

Page 142 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 5 of 5 Figure 3 - Broken Grating Section (2T41-BO03B)

Page 143 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 1 of 6 Status: YZ NE] U[]

Seismic Walkdown Checklist (SWC)

E~quipment ID No. 2T41-BOO3A Equip. Class, 10 Equipment Description RHRICS PUMP ROOM COOLER A Location:. Bldg. REACTOR Floor El. 119' Room, Area NE Diangonal Room Manufacturer, Model,. Etc. (optional but recommended)

Instructions for Completing: Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage I. Is the anchorageconfiguration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)?

YN NEI

2. Is the anchorage free of bent, broken, missing or loose hardware?

Holes with missing anchors but replaced with tabs and new anchors.

SWE's have determined that this configuration is acceptable and consistent with anchorage shown in SQUG package based on referenced SEWS package and Calculation

3. Is the. anchorage free of corrosion that is. more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?

Component anchored to Platform supporting steel.

5. Is the anchorage configuration consistent with plant documentation?

(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

SEWS Package 2T41-BO03A, Dated 2115/1994 and Calc SCNH-1 1-007, Dated 4/19/2.012

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE N/AE-YN NEI UE" N/AE YEI NE UE N/AZ YZ NE UE N/AEl YN NEI UE]

Enter the equipment class name from Appendix B:, Classes of EqUipment.

Page 144 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 2 of 6 Status: YZ N[] UI-]

Seismic Walkdown Checklist (SWC)

Equipment ID No. 2T41-BOO3A Equip. Class' 10 Equipment Description RHR/CSPUMP ROOM COOLER A Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?

YZ NEI UEI N/AE

8. Are overhead equipment, distribution systems,, ceiling tiles and lighting, YZ N[

U-- N/AE]

and masonry blockvwalls not likely to collapse onto the equipment?

9. Do attached lines have adequate, flexibility to avoid damage?
10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

Y[ NE" UE1 N/Afl YN NEI UF1 Other Adverse Conditions

11. Have you looked for anid found no otherseismic conditions that could YZ NE UE]

adversely affect the safety functions of the equipment?

Comments (Additional.pages may be~added as necessary)

There are missing housing cap screws these cap screws have no matching hole in the mating flange to place a screw. Therefore, the missing cap screws do not pose a seismic issue for the component.

In addition-, the Area Walk-by is performed for component 2 T41NO21A.

Evaluated by:John McFarland, Jeff Horton Date: 09/24/2012 09/24/2012 Page 145 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2T41-BO03A Equip. Class' 10 Equipment Description RHR/CS PUMP ROOM COOLER A NO. SNCH082-RPT-02, VERSION 1.0 Sheet 3 of 6 Status: YZ NEI U[-

Photographs Figure I Equipment ID: 2T41-BO03A Page 146 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 4 of 6 Figure 2 Component Picture Page 147 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 5 of 6 Figure 3 Typical View of Anchor Configuration of Component Page 148 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 6 of 6 Figure 4 View of Casing Missing Cap Screws Page 149 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2T41-BOO5B Equip. Class, Equipment Description HPCI Room Cooler NO. SNCH082-RPT-02, VERSION 1.0 Sheet i of 4 Status: YM NR; UL' Location: Bldg. REACTOR Floor El. 87 Room, Area HPCI Room Manufacturer, Model, Etc. (optional but recommended)

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage,

1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)?

YC N&

2. Is the anchorage free of bent, broken, missing or loose hardware?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?

Equipment is mounted on a platform so there is no concrete.

5. Is:the anchorage configuration consistent with plant documentation?

(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations,- is the anchorage free of potentially adyerse seismic conditions?

YM Nil UO N/AC-YZ NCl UCI N/AC-YT NO UC1 N/AZ YC NCD UC N/AE]

Y0 NEI Ui]

I*Enter the equipment class name from Appendix B: Classes of Equipment.

Page 150 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 2 of 4 Status: Y1 N[:] uTA Seismic Walkdown Checklist (SWC)

Equipment ID No.

2T41-BOO Equip.

Equipment Description HPCi Room Cooler Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?
8. Are overhead equipment, distribution systems,, ceiling tiles -andlighting, and masonryblockwalls not likely to collapSe onto the equipment?
9. Do attached lines have adequate flexibility to avoiddamage?.

S10'. Based on the above seismic interaction evaluations, isequipment free of potentially adverse seismic interaction effects?

Y* N f UO NJAF-Y NO U]. N/AFJ Y& NO Vf N/AO Y2 NO Ul Other Adverse Conditions iI. Have you looked for and found noother seismic conditions that could Y9 NN UV

,adversely affect the safety functions of the equipment?

Comments (Additionaltpages may be. added as-necessary)ý See Component P41 -FO35B for 4req Walk-by :Checklist. The instrument HOl shown in:Figure 2 is discussed in the Area Walk-By Checklist f6r component P41-FO35B. 1PEEE open item modifiCation to the HVAC duct supportsý addressed in Calculation SCNH9R5002, and DCP 94-017 has been verfled as in-stalled by this walk-down.

Note: P41-F035B refers to MPL # 2P41-F035B Evaluated by: Johi McFarland Jeff Horton Date: 09127/2012 09/27/2012 Page 151 of 394

ATTACHMENT 3: SEISMIC WALKIDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2T4 1-B005B8 Equip. Class, Equipment Description HPCI Room Cooler NO. SNCH082-RPT-02, VERSION 1.0 Sheet 3 of 4 Status: YZ NEI UL-Photographs Figure 1 - Equipment ID No (2T41-BO05B)

Page 152 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 4 of 4 Figure 2 - Equipment Elevation (2T41-B005B)

Page 153 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 1 of 5 Status: YE] N9 U[]

Seismic Walkdown Checklist (SWC)

Equipment ID No. 2T46-DOOIB Equip. Class. 10 Equipment Description SBGT FIL TER TRAIN Location: Bldg. REACTOR Floor El. 185 Room, Area 2R303 Manufacturer, Model, Etc. (optional but recommended)

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end, of this checklist for documenting other comments.

Anchorae 1.. Is the anchorage configuration verification required (i,.e., is th.e item one of the 5.0%, of SWEL items requiring such verification)?

YEI NO

2. Is the anchorage free of bent, broken, missing or loose hardware?

One of the 18 bolts anchoring the train to the concrete is missing or cut.

A CR has been initiated forthis purpose (CR515744).

3. Is the anchorage :fee of corrosion that is more than mild surface oxidation?
4. Is. the anchorage free of visible cracks in the concrete near the anchors?
5. Is the anchorage configuration consistent with plant documentation?

(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage. free of potentially adverse seismic conditions?

YE-NO UE N/AE1 Y9 NE UE-N/AE[]

VYO NEI UE-N/A YEI NEI UEO, N/AZ YEI NO UE-i Enter the equipment class name from Appendix B-Classes of Equipment.

Page 154 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 2 of 5 Status: YE] N23 U-]

Seismic Walkdown Checklist (SWC)

Equipment'lD No. 2T46-DOOIB Equip.,

Equipment Description SBGT FILTER. TRAIN Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?
8. Are overhead equipment, distribution systems, ceiling tiles and lighting,,

and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?
10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismicý interaction effects?

YO NEI UE-N/Afl YN NEI UL] N/AE]

YZý NEI ULI N/AE YN NE UE]

Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Yz, NEI ULI adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary)

In some locations under the train, there are gaps between the steel plate and the concrete (<O.25").

However, the bolts are engaging and they are in tension. Therefore, these existing gaps do not, pose a seismically adverse condition. The equipment has very heavy and has a large footprint.

Therefore, the existing gaps do not pose a; seismically adverse condition.

Housekeeping issues: Flange blinds spotted loose on the train. Two washers are found near the train. These loose items are not seismic concerns and can not impact sensitive equipment.

Cut cable was spotted above the panel for the train. A CR has been initiated to identify the cable and cap it (CR516629).

Unistrut support framing carrying cables over the train seems to have surface corrosion. Since the loads are light and corrosion is mild, this is judged not to be an adverse seismic condition.

Evaluated by:

Date: 9/11/2012 WESLEY WILLIAMS 9/1112012

/

Page 155 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2T46-DOOIB Equip. Class' 10 Equipment Description SBGT FILTER TRAIN NO. SNCH082-RPT-02, VERSION 1.0 Sheet 3 of 5 Status: YE] N U[-]

Photographs Page 156 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 4 of 5 Page 157 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 5 of 5 Cut cable shown coming from the panel.

Page 158 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

NO. SNCH082-RPT-02, VERSION 1.0 Sheet 1 of 5 Status: YEI NEI UM Equipment ID No. 2P33-BOOIB Equip. Class1 11 Equipment Description H2102 Analyzer Samnle Chiller Location: Bldg. REACTOR Floor.El. 158 Room, Area. Near Equipment Hatch Manufacturer, Model, Etc. (optional but recommended)

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the followingquestions may be used to record the results ofjudgments and findings. Additional space. is provided at the end of this checklist for documenting other comments.

Anchorage

1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)?

Anchorage is located inside the cabinet and cannot be reviewed without opening the cabinet.

2. Is the anchorage free of bent, broken, missing or loose hardware?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?
5. Is the anchorage configuration consistent with plant documentation?

(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NE YE] NO UZ N/AE YEi NEI UZ N/AL YE NEI U9 N/AL!

YEr NEI UZ N/AE-YEI NEI UZ Enter the equipment class name from Appendix B: Classes of Equipment Page 159 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 2 of 5 Status: YE] NE] U[N Seismic Walkdown Checklist (SWC)

Equipment ID No. 2P33-BOOIB

.Equip.

Class, 11 Equipment Description H2/02 Analyzer Sample Chiller Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?

Panel 2D11-PO10 sits next to H2/02 Analyzer Sample Chiller 2P33-BOOiB. There is between a 1/16" and a 1/8" gap between the two components, and the components are not tied-together. During a seismic event, it is likely that the two will impact one another.

However, per conversations with a recent former systems engineer for this system, there are no essential relays or similarsensitive equipment inside, either cabinet, so the impact does not have the potential to create a condition that is adverse to plant safety. The impact between the cabinets will not have enough force 'to damage the rugged cabinets, so it isjudged that there is no potentially adverse seismic condition.

8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not. likely to collapse onto the equipment?
9. Do attached lines have adequate flexibility to avoid damage?
10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic, interaction effects?

YEI NEi UM N/AEl YN NEI UEi N/A[]

YN NEI UEi N/AU YE NEI UN Other Adverse Conditions 111. Have you looked for and found no other seismic conditions that could YN NE UEi adversely affect the safety functions of the equipment?

Comments (Additional pages nmay be added as necessary)

None

~~1 Evaluated by-John McFarland i Jeff Horton Date: 09/11/2012 09/11/2012 Page 160 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2P33-BOOIB Equip. Class' 11 Equipment Description H2102 Analyzer Sample Chiller NO. SNCH082-RPT-02, VERSION 1.0 Sheet 3 of 5 Status: YE] NE] UM Photographs Figure 1 - Equipment ID No (2P33-BOOIB)

Page 161 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 4 of 5 Figure 2 - Equipment Elevation (2P33-B00 IB)

Page 162 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 5 of 5 Figure 3 - Small Gap between Panels (2P33-B00 IB)

Page 163 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 1 of 3 Status: YM: Nn] U[]

Seismic Walkdown Checklist (SWC)

Equipment ID No. 2R43-COO6A Equip. Class Equipment Description DG 2A AIR COMPRESSOR Location: Bldg. DIESEL Floor El. 130 Room, Area 2A Manufacturer, Model,,Etc. (optional but recommended)

Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results.ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.

Anchorage

1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)?

Y"I NO

2. Is the anchorage free of bent. broken, missing or loose hardware?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is theanchorage free of visible cracks in the concrete near the anchors?
5. Is the anchorage configuration consistent with plant documentation?

(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YO NEI-U-- N/AEl YO ND UI-N/AU YO NEIl Ur1 N/AU]

YE] NEI UI-] N/AOz YO NI UEU

'Enter the equipment class name from Appendix B: Classes of Equipment, Page 164 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS NO. SNCH082-RPT-02, VERSION 1.0 Sheet 2 of 3 Status: YN NE] U[-

Seismic.Walkdown Checklist (SWC)

Equipment ID No. 2R43-COO6A Equip. Class, 12 Equipment Description DG 2A AIR COMPRESSOR Interaction Effects

7. Are soft targets free from impact by nearby equipment or structures?

YN NO U-N/AO

8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y0 NEIl UE N/AEl and masonry block walls not likely to, collapse onto the equipment?

Fluorescent light bulbs may fall on top of the equipment.However, the damage was judged to be non-significant since the bulb is very light and the equipment is relatively rugged.

9. Do attached lines have adequate flexibility to avoid damage?
10. Based on the aboveseismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?

YER NEI UFI N/AL]

YN NEI Ul Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YN NEI UEl adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary)

Area walk by is included with the package of generator 2A4, 2R43-SOOIA.

Evaluated by: Kursat Kinali

=

Weslev Williams 7,07LZV Date: 91/72012 9/7/2012 Page 165 of 394

ATTACHMENT 3: SEISMIC WALKDOWN CHECKLISTS Seismic Walkdown Checklist (SWC)

Equipment ID No. 2R43-COO6A Equip. Class' 12 Equipment Description DG 2A AIR COMPRESSOR NO. SNCH082-RPT-02, VERSION 1.0 Sheet 3 of 3 Status: YN NE-- U'-

Photographs Page 166 of 394