ML12338A533

From kanterella
Jump to navigation Jump to search
Official Exhibit - ENT000369-00-BD01 - Entergy Nuclear Vermont Yankee Transcript
ML12338A533
Person / Time
Site: Indian Point  
Issue date: 03/29/2012
From:
Atomic Safety and Licensing Board Panel
To:
SECY RAS
References
RAS 22113, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12338A533 (35)


Text

United States Nuclear Regulatory Commission Official Hearing Exhibit Entergy Nuclear Operations, Inc.

In the Matter of:

(Indian Point Nuclear Generating Units 2 and 3) c,.\..tJt-f\ RfGlJ<.q" ASLBP #: 07-858-03-LR-BD01

!~~o" Docket #: 05000247 l 05000286 Exhibit #: ENT000369-00-BD01 Identified: 10/15/2012 0

~

~

Admitted: 10/15/2012 Withdrawn:

~

....,1-:

i 0' Rejected: Stricken:

" ****1l '" Other:

ENT000369 Submitted: March 29, 2012 Official Transcript of Proceedings

  • NUCLEAR REGULATORY COMMISSION

Title:

Entergy Nuclear Vermont Yankee Docket Number: 50-271-LR; ASLBP No. 06-849-03-LR Location: Newfane, Vermont DOCKETED USNRC August 15, 2008 (4:00pm)

Date: Monday, July 21 , 2008 OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF Work Order No.: NRC-2296 Pages 694-879 NEAL R. GROSS AND CO., INC.

Court Reporters and Transcribers 1323 Rhode Island Avenue, N.W.

Washington, D.C. 20005 (202) 234-4433

\ :

800

  • 1 2

3 JUDGE KARLIN:

MR. STEVENS:

calculations with 6909 going back

-- so people can hear.

I've 2

done quite a few years as part few 4 of the review process included. And we did the -- we*

5 calculated CUFens for the VY, all nine locations that 6 were evaluated for environmental fatigue, 7 And the CUFens using 6909 are lower .than 8 those reported by Entergy in the testimony for all 9 nine locations. Arid that would support what -- Mr.

10 Fair's prior testimony or the ACRS comment that he 11 made earlier.

12 JUDGE REED: Mr. Stevens, In fact, the

  • 13 14 15 only correct?

change was the MR. STEVENS:

Fens, not No, sir.

the CUFs, We used lS that 16 JUDGE REED: Did you also change the CUFs 17 In this --

18 MR. STEVENS: Y~s.We used 6909 in its 19 entirety, so we used the curves, calculated Fens in 20 accordance with that document, and also CUFens as a 21 product of the two.

22 JUDGE REED: Okay. So we are looking at 23 a result that was attained by changes both in the 24 environmental effects as well as how you did the basic

  • 25 CUF analysis.

(202) 234-4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 www.nealrgross.com

8 01 II

  • 1 2

3 MR. STEVENS:

JUDGE REED:

J UDGE WARDWELL:

Yes, sir.

Okay.

How long does that 4 analysis take you t o do?

5 MR. STEVENS: Approximately four hours.

  • 6 JUDGE WARDWELL: Thank you.

7 JUDGE KARLIN: And let's just clarify.

8 Dr. Reed's question I think was reasonably -- was well 9 taken, and I think the clarification is you're saying 10 NUREG-6909 involves more than just changing the Fen 11 calculation, is that correct?

12 MR . STEVENS: That's correct.

  • 13 14 15 changes?

JUDGE KARLIN:

MR. STEVENS: .

And it involv es what other It involves calculating 16 fatigue wi th revised fatigue curves, compared to 17 those 18 JUDGE KARLIN: In air . .

19 MR. STEVENS: Correct.

20 JUDGE KARLIN: Right.

21 MR. STEVENS: Compared to the AS ME code 22 fatigue curve.

23 JUDGE KARLIN: And what maybe we can 24 just ask what the values you derived -- .what were the

  • 25 values (202) 234-4433 for the nine -- what, NEAL R. GROSS nine COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.w.

WASHINGTON, D.C. 20005-3701 locations, S1.X www .nealrgross.com

Il "

I 802

  • 1 2

3

. II I

locations, nine pieces 6f equipment?

I'll report MR. STEVENS:

the values Okay.

using The nine items - - and 6909, and these are 4 CUFens. Item* 1 was the RPV shell bottom head 5 location, CUFeri .0263. Item 2 is the RPV shell at 6- shroud support location. CUFen was .2637. Item 3 was 7 the feedwater nozzle blend radius. CUFen was .2175.

8 Item 4 was the recirculation RHR Class 1 9 piping return T: CUFen .4151. Item 5 was the 10 recirculation inlet nozzle forging. CUFen .1921.

11 Item 6, recirculation inlet nozzle safe-in, CUFen 12 .0152.

  • 13 14 15 forging, Item CUFen 7,

.0278.

forging blend radius, CUFen .0524.

recirculation Item 8, core outlet nozzle spray nozzle Item 9, feedwater 16 Class 1 piping, CUFen .1350.

17 JUDGE KARLIN: And what was the highest 18 CUFen calculated by that in that -analysis?

19 MR. STEVENS: That would be Item 4, 20 recirculation, RHR Class 1 piping return T of .4151.

21 JUDGE KARLIN: Okay.

22 JUDGE WARDWELL: How did this analysis --

23 how was this analysis performed in regards to the 24 three sets of analyses that were presented as part of

  • 25 the testimony (202) 234*4433 in regards NEAL R. GROSS to the COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 basic initial www.nealrgross.com

803 e 1 2

calculation performed in the application, were done for the refined analysis, those that and those that 3 were done for the confirmatory analysis? Analyses, I 4 should say.

5 MR. STEVENS: We started with the -- all 6 of the calculati o ns that Entergy .has done o v er the 7 past year. And for the three nozzles that are a part 8 of the testimony -- the recirculation outlet nozzle, 9 the core spray nozzle, and the feedwater nozzle -- we 10 used the refined analyses.

11 And the analysis -- the calculations we 12 did here started with the stress results that went e* 13 14 into the fatigue calculation. So we used --you know, the majority of the analysis remained unchanged. We 15 just took the stresses that fed into .the fatigue 16 analysis . We replaced the fatigue curve and 17 recalculated Fens. The very tail end of the analysis 18 was reperformed.

19 JUDGE WARDWELL: So let me make sure I 20 understand this correctly. You used the stress 21 analyses that -- the most recent stress analyses for 22 a given component based on whether or not the -- it 23 was -- the most recent was done as either a -- the 24 original analyses, refined analyses, Or confirmatory e 25 analyses.

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

(202) 234*4433 WASHINGTON, D.C. 20005*3701 www.nealrgross.com

804

  • 1 MR . STEVENS: .We did not use the 2 confirmatory calculation for the feedwater nozzle, our 3 reason being to be consistent with these comparisons.

4 JUDGE WARDWELL: Strictly the refined for 5 the three nozzles and then they're basically 6 MR. STEVENS: That's correct.

7 JUDG E KARL IN : Does that mean that the 8 Green's function issue was eliminated, or still -- as 9 I understand it , we hav e three anal y ses essentially 10 that you submitted, that Entergy submitted. First ,

11 it's the initial analyses, right? With the 12 application. Is that correct?

  • 13 14 15 MR. STEVENS:

JUDGE KARLIN:

That's correct .

Then, reanalysis in September and December of '07, right?

there was the 16 MR . STEVENS: Correct.

17 JUDGE KARLIN : And that was for all seven 18 locations or pi ec es of equipment -- all nine, I'm 19 sorry. And then, there was a confirmatory analysis 20 with regard to the feedwater nozzle, right?

21 MR. STEVENS: Correct.

22 JUDGE KARLIN: So that's the terminology 23 I'm going to use the initial analysis, the 24 reanalysis for all of them, and then the confirmatory

(202) 234-4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 And as I hear what www.nealrgross.com

805

  • 1 you're saying, you used the approach of the 2 reanalysis, and then you applied . NUREG-6909 to that, 3 is that right?

4 MR. STEVENS: That's right.

5 JUDGE KARLIN: Now -~ well, then, there 6 may be a concern about that because the whole reason 7 that the confirmatory analysis was done was because, 8 as I understand it, the staff raised concerns about 9 the simplification of being caused by using simplified 10 data in the Green's function. Are you with me?

11 MR. STEVENS: Yes, sir.

12 JUDGE KARLIN: Was that -- is that problem

  • l3 14 15 still inherent in your reanalysis of these?

MR. STEVENS: Well, clarify that I don't consider that' to bea problem I'd just like to 16 with those analyses. But the presence of the Green's 17 function is in the three evaluations of the nozzles in 18 these results I reported to you.

19 JUDGE WARDWELL: And just for

.20 clarification, is it fair to say that the reason you 21 did that is just to compare it to using 6909 versus 22 5783 -- what's the other NUREG number -- approach?

23 You did it for comparison purposes rather than any 24 final calculation of record.

  • 25 (202) 234-4433 MR. STEVENS: Yes, NEAL R. GROSS sir .

COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.w.

WASHINGTON, D.C. 20005-3701 I believe at www.nealrgross.com

806

  • 1 least two of the parties that would be Entergy and 2 NRC Staff have made some statements that the newer 3 regulatory guide and associate NUREG generally provide 4 lower results on a CUFen standpoint than the ones used 5 for license renewal. And so these were done to 6 support those statements further.

7 JUDGE WARDWELL: Okay.

8 JUDGE REED: Mr. Stevens, I need to 9 understand better how these calculations are actually 10 performed. We've kind of jumped into thE: middle here, 11 and I need to come back more to the beginning. You 12 work for SIA, is that correct?

  • 13 14 15 MR. STEVENS:

JUDGE REED:

th8se calculations.

That's correct.

And you personally did all of 16 MR. STEVENS: Not -- no, sir. I was -- I 17 did a few of them, and I supervised the staff that did 18 the calculations.

19 JUDGE REED: But you are intimately 20 familiar with the methodology that goes into 21 calculating a CUFen number for a particular component.

22 MR. STEVENS: Yes, sir.

23 JUDGE REED: So you know from beginning to 24 end exactly how that calculation proceeds and what

  • 25 assumptions are made .

(202) 234-4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE. , NW.

WASHINGTON, D.C. 20005*3701 www.nealrgross.com

807

    • 1 2

3 MR. STEVENS:

JUDGE REED:

discourse on how that's done?

Yes, sir.

Could you give us a brief I don't want a half-4 hour tutorial. I want a five-minute description of --

5 take a particular transient or ~ set of transients 6 that are analyzed and tell us exactly how you 7 calculate and arrive at a CUFen number.

8 MR. STEVENS: Okay.

9 (Pause. )

10 I'm going to look my 11 testimony up, so I can keep this as brief as possible.

12 I apologize fo r the delay.

  • 13 14 15 start b~

JUDGE REED:

talkin~

No, that's fine.

about the kinds of transients that affect, say, a feedwater nozzle and how those lead to You might 16 stresses, and then how you calculate the stresses, 17 then how you determine what the maximum allowable 18 stresses are, so that you -- arid I don't know how to 19 do these calculat*ions, so I don't want to lead you too 20 far.

21 MR. STEVENS: Okay.

22 JUDGE REED: But--

23 MR. STEVENS: I'll try and be brief but 24 descriptive here. So we have to -- we have to collect

  • 25 all of the loadings for a particular component we're (202) 234*4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005*3701 www.nealrgross .com

808

  • 1 2

3 evaluating, and those would .come from --

louder?

JUDGE REED: Can you speak jusi ~ little 4 MR. STEVENS: Okay. Sorry. we have to 5 collect all of the loadings for a particular component 6 in order to analyze it from a stress and fatigue 7 standpoint. We would typically collect those loadings 8 from the design specifications for the component by 9 the v endor or manufacturer. So we would collect 10 geometry and we would construct Cl. model that would 11 allow us to calculate stresses for all loadings. In 12 this case, a finite element model is an ind1)stry

  • 13 14 15 standard, so we would model that component geometry JUDGE REED: So if I may interrupt, these are static loadings on a particular component. You 16 calculate a stress tensor for that or a stress field?

17 MR. STEVENS: Correct.

18 JUDGE REED: Okay. So the issue of 19 transients has not yet come into it.

20 MR .. STEVENS: Not yet.

21 JUDGE REED: Okay.

22 MR. STEVENS: As a part of the loadings, 23 though, there are thermal transients which are loads 24 that vary with time, and we would also use the finite

  • 25 element model to evaluate stresses as a function of (202) 234*4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.w.

WASHINGTON, D.C. 20005*3701 www.nealrgross.com

80 9

  • 1 2

3 time for those loadings.

JUDGE REED: So y ou sna pshots during a transient, and all of which have take a series of 4 different loadings is --

5 MR, STEVENS: That's 6 JUDGE REED: and calculate the 7 stresses?

8 MR. STEVENS: Yes.

9 JUDGE REED: Okay. I'm with you so far.

10 MR . STEVENS: So during a thermal 11 transient, we would have a stress history versus time 12 for that transient. And then, knowing how pressure

  • 13 14 15 and other loadings vary during that would calculate those stresses and combine them.

is all a linear, elastic analysis, so we would combine transient, This we 16 them by superposition. And we would get a stress --

17 a total stress history for the component from those 18 analyses.

19 JUDGE REED: For a particular transient, 20 you develop a stress history, meaning the stress as a 21 function of time.

22 MR. STEVENS: That's correct.

23 JUDGE REED: Okay.

24 MR . STEVENS: And then, we have 20

  • 25 transients, we would repeat that process 20 times and (202) 234-4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

WASHINGTON, D.C. 20005-3701 www .nealrgross.com

810

  • 1 2

3 come up with 20 stress . histories.

JUDGE REED: Now, when transients," you don't mean the same thing happeriing you say "20 4 again and again . You mean 20 different kinds of 5 the plant responding to something happening.

6 MR. STEVENS: That's correct .

7 Different 8 JUDGE WARDWELL: Are these plant-specific?

9 MR. STEVENS: Yes. So you are correct.

10 There would be 20 different transients of a different 11 type. Each of those transients would occur a 12

  • diffeient number of times. So the quantity of those

would JUDGE REED:

be specified and would And some of the transients be 16 are more severe than others?

17 MR. STEVENS: That's correct, 18 JUDGE REED: And would lead to larger 19 stresses?

20 MR. STEVENS: That's correct.

21 JUDGE REED : But they may occur fewer 22 times, so you may have a smaller transient that occurs 23 much more frequently that lS going to contribute 24 relatively more to the ultimate answer, is that

  • 25 correct?

(202) 234*4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.w.

WASHINGTON, D.C. 20005*3701 www.nealrgross.com

811

-. 1.

2 3

MR_ STEVENS:

JUDGE REED:

MR. STEVENS:

That's correct-_

Okay.

So now, once we

  • have the 4 stress history, and we would feed that into a fatigue 5 analysis, and the fatigue analysis first -tells us how 6 to take those stress histories and link them together 7 or combine them in such a way that we can count number 8 of stress fluctuations on a component. Stress 9 fluctuations are what lead to fatigue.

10 JUDGE REED: So it's not stress, but 11 fluctuations in stress.

12 MR. STEVENS: That's correct. It requires

  • 13 14 15 a stress fatigue.

fluctuation JUDGE REED:

to contribute Okay.

any kind of 16 MR. STEVENS: So, and the ASME code gives 17 us guidelines ~nd methodology for doing all of £his 18 analysis. And, ih particular, counting cycles, how 19 that's done in ~ conservative fashion, because in a 20 fatigue analysis of the component we don't necessarily 21 know the order of occurrence of the events. So the 22 methodblogy assumes the worst possible occurrence by 23 pairing the extreme stresses together.

24 So when we go through this counting

  • 25 process, we take the highest extreme, the highest peak (202) 234-4433 NEAL .R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 www.nealrgross.com

812

  • 1 2

3 stress with the lowest low stress and pair.

to get these str e ss fluctuations.

JUDGE REED: So that's a the~e conservative off 4 assumption you are making? Is that the point?

5 MR. STEVENS: Yes, sir.

6 JUDGE REED: So you don't take the actual 7 stress history of the transients. You somehow take 8 the high stress and the low stress and pair them up 9 to --

10 MR. STEVENS: Well, when we -- when we --

11 that's correct.

12 JUDGE KARLIN: May I ask a question in

  • 13 14 15 this -- on any gi v en transient, you are talking about the stress load that occurs during a transient, right?

MR . STEVENS: Yes.

16 JUDGE KARLIN: Do you have monitors that 17 are telling you what the stress load is on this 18 particular val v e or nozzle or outl~t? How do you know 19 -- where are you getting the data that tells you how 20 much stress they have?

21 MR. STEVENS: The stress comes £rom the 22 finite element analysis of that component.

23 JUDGE REED: And what code is being used 24 to do that analysis?

  • 25 (202) 234*4433 MR . STEVENS: We use NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.w.

WASHINGTON, D.C. 20005*3701 the ANSYS fini te www.nealrgross.com

813

  • 1 2

3 eleme nt c ode.

available code ?

JUDGE REED: And that is a commercially-4 MR. STEVENS: Yes, sir.

5 JUDGE REED: And ANSYS stands for?

6 MR. STEVENS: I don't recollect.

7 JUDGE KARLIN: Could you spell the 8 acrQnym?

9 MR. STEVENS: A-N-S-Y-S.

10 JUDGE KARLIN: Okay.

11 JUDGE REED: And that code is in wide u s e 12 or very narrow use throughout the industry or --

JUDGE REED:

widely used in And what can you say about the 16 the accuracy of the code , the benchmarking of the 17 code? How confident are you that it is giving you 18 correc t numbers?

19 MR. STEVENS: The code lS extensively 20 benchmarked. It comes with verification manuals that 21 where analyses are run and compared to theoretical 22 or hand solutions and checked for accuracy. It is all 23 controlled and developed under a 10 CFR 50 Appendix B 24 quality assurance program .

  • 25 (202) 234-4433 And when we bring that code into our house NEAL R. .GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 www.nealrgross.com

814

  • 1 2

3 we also have to adopt it as part of that program and do the extensi v e 6hecking accordance with those verification manuals, and then and verification in 4 ensure that our use is consistent with those -- the QA 5 progra~ and those ~hecks .

6 JUDGE REED: So when you genera te a f ini te 7 element mesh for ANSYS, do you do a mesh refinement 8 study?

9 MR. STEVENS: Generally not on a case-by-10 case basis. This is one of the a~eas where it does 11 require anal y st judgment and experience to do it 12 properly. 'VIle have done those as a part of our company

  • 13 14 15 extensi v ely for other a ~ase-by -case basis.

JUDGE REED:

~easons, but 'we don't do it on Would it not be possible that 16 as you refined the mesh you would find a little local 17 area where the stress is much-higher than it would be 18 calculated with a much coarser finite element grid?

19 MR. STEVENS: That's possible. I don' t 20 ' think tha t tha t ' s I would not agree with that 21 assessment for the models used for Vermont Yankee.

22 JUDGE REED: But you can't rule it out, 23 since you hav en't done the mesh refinement study.

24 MR. STEVENS: No. We can only rule it out

  • 25 based on our experience.

(202) 234-4433 NEALR. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 www .nealrgross.com

815

  • 1 2

3 JUDGE REED: So you can't certain that higher stresses might not be generated if you refined the meshes in your calculations.

actually be 4 MR. STEVENS: Generally, that kind of an 5 artifact would come near discontinuities.

6 JUDGE REED: Yes.

7 MR. STEVENS: And the locations that we're 8 evaluating here don't have those kinds of 9 discontinuities.

10 JUDGE REED: Okay.

'11 MR . STEVENS: So I'm confident that y6u 12 -would not experience a significant change in stress

  • 13 14 15 with your suggestion .

believe JUDGE REED:

that you have So is it your point that you resolved the stress field 16 reasonably accurately with the finite element meshes 17 you're using in your calculations?

18 MR. STEVENS: Yes, Slr.

19 JUDGE REED: Okay. I hope we can proceed 20 with how you do the calculation now. And I'm sorry 21 that 22 (Judges confer.)

23 JUDGE WARDWELL: Dr. Hopenfeld, do you 24 have any major objections or arguments with the way

  • 25 Mr. Stevens just described the approach that they use?

(202) 234-4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

WASHINGTON, D,C. 20005-3701 www,nealrgross,com

816

  • 1 2

3 DR. HOPENFELD:

JUDGE WARDWELL:

Yes .

understanding o f h ow the approach was used?

Is that your 4 DR. HOPENFELD: Yes. Yes, Your Honor. I 5 understand exactly what he's talking about.

6 JUDGE WARDWELL: And is that your 7 understanding of how it was performed when you 8 supplied your testimony?

9 DR. HOPENFELD: Yes. Yes, it is.

10 JUDGE WARDWELL: Okay. That's all I 11 needed to know. We'll get to you in a moment. Just 12 wanted to make sure we're all in agreement .

  • 13 14 15 me up.

DR . HOPENFELD:

JUDGE KARLIN:

Well, make sure you pick No. But I'm trying to --

16 when you said yes, do you have disagreements wi th what 17 he just said, or are you on board?

18 DR. HOPENFELD: I have no disagreement 19 with what he said.

20 JUDGE KARLIN: Okay.

21 DR. HOPENFELD: But that's only part of 22 it.

23 JUDGE KARLIN: Yes, right. We'll get to 24 that .

  • 25 (202) 234-4433 DR. HOPENFELD:

NEAL R. GROSS That's COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 not the whole www.nealrgross.com

817

    • 1 2

3 story.

co be cl~ar JUDGE KARLIN:

on that.

Okay. ' Fine. I just want We'll get the rest of the story.

4 DR. HOPENFELD: Okay.

5 JUDGE WARDWELL: Go ahead. I just wanted 6 to --

7 JUDGE REED: Well, we were partway through 8 this issue of exactly how you take a series of 9 transients and calculate a CUFen number.

10 MR. STEVENS: Correct. So once I have all 11 of these different stress histories for, arbitrarily 12 talking, 20 transients here, the ASME code tells me

  • 13 14 15 how to start to pair these together to get fluctuating stresses that would contribute to fatigue.

to combine these transients.

So I have As I said, it does it in 16 a conservative way that it takes the most the 17 extreme stresses and pairs those and uses those 18 fluctuating stresses into a fatigue analysis.

19 And very, very simplistically, if I took 20 the highest stress and the lowest stress that would be 21 a stress range, and alter -- a possible alternating 22 stress range that tha't component may have been exposed 23 to --

24 JUDGE REED: For that one kind of

(202) 234-4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE" NW.

WASHINGTON, D.C, 20005-3701 www.nealrgross.com

818

MR . STEVENS:

which could For that one pairing of t wo be from two Remember, I'm going after extremes to get different the most conservative fluctuation of stress that component would have seen.

JUDGE REED: I'm failing completely to understand why you picked the high stress from one transient and the low stress from a completely different transient that presumably occurs at some other time in the plant's history.

MR. STEVENS: Well, because that -- the component would see the stresses caused by both of

terms of a fluctuating stress --

JUDGE REED: These could pe days, months So in apart, though.

MR. STEVENS: Could be years apart. But you see that a typical design analysis does not know the order of ~vents. So if it's analyzing 20 transients, and it has no particular knowledge on the order those events could ociciur, and i f i t puts them next to each other as if they occurred minutes apart, that would be the most conservative.

JUDGE REED: And that's what you do .

  • (202) 234-4433 MR. STEVENS: That's what we do.

NEAL R GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 And it's www.nealrgross.com

819

  • 1 2

3 a conservative way of stating the fluctuations that that component will go through, not knowing the order of events ahead of time.

extreme stress 4 JUDGE REED: I'm struggling to understand.

5 I want to ask you at some point -- you've got 20 6 different kinds of transients.

7 MR. STEVENS: Correct.

8 JUDGE REED: Presumably all sorts of 9 things that happen to the plant -- changes in power 10 level, turbine trips, whatever .. And these are all 11 stressing this particular component, and they are all 12 occurring with different frequencies, some occurring

  • 13 14 15 once a year, some occurring every several years, some occurring every decade.

MR. STEVENS:

Am I right, That's correct.

in this 16 . JUDGE REED: So what I want to understand 17 is how you ultimately take all of those various 18 transients, calculate some sort of utilization 19 factors, and then cumulate them up into a CUF.

20 MR. STEVENS: Let me try again. Let's 21 start with the stress history for one transient. So 22 I have one transient that has temperature during the 23 time, and I have calculated stresses for that 24 transient. So I have a stress versus time plot I can

(202) 234*4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005*3701 www.nealrgross.com

820

  • 1 2

3 transietits JUDGE REED:

MR.

th~t I STEVENS:

Okay.

Now do the same thing.

I have 19 And what I'm other 4 going to do is I'm going to take the stress history 5 for each of those other 19 transients, I'm going to 6 tag it on to the end of the stress history for 7 transient number 1. Now what I've got is this very, 8 very long stre~s history versus time that has all 20 9 transients attached together to each other.

10 JUDGE WARDWELL: These aren't 20 actual 11 transients that occurred at Vermont Yankee. These are 12 20 different types of transients that are generically

  • 13 14 15 experienced at a might be at Vermont Yankee.

boiling water MR. STEVENS:

reactor similar These are specified by the to 16 designer for the plant.

17 JUDGE WARDWELL: Okay.

18 MR. STEVENS: Sb I now have a long stress 19 history, stress versus time, that represents 20 20 transients attached together, one after another.

21 Now, when I put that history together, I 22 made a big assumption on the order of those 23 transients. If I would have done transient I, 24 transient 2, transient 3, then that stress history

  • 25 represents that the order of occurrence of those 20 (202) 234*4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005*3701 www.nealrgross.com

821

  • 1 2

3 transients was in that order -- time order I put them in.

JUDGE WARDWELL: And the time is not a 4 real time, it is the linkage of all of the transients, 5 and they are attached based on the link that the 6 transient occurs. Then, you immediately start the 7 next transient after that

  • one is over with, is that 8 correct?

9 MR. STEVENS: Yes, that's correct.

10 JUDGE REED: So you are putting the plant 11 through all of its paces basically one right after the 12 other with no intervening period of six months of

  • 13 14 15 stable operation, is that MR. STEVENS:

JUDGE REED:

That's correct.

Okay.

16 JUDGE KARLIN: Let me just -~ may I ask 17 basic questions, where we're going here. I was 18 concerned by the answer you gave to Dr. Wardwell's 19 question. Are these -- when you were talking about 20 the 20 transients, are these actual transients that 21 occurred at Vermont Yankee that you were basically 22 saying, okay, there are 20 transients and here is how 23 much stress - - transient 1 gave X stress, transient 2 24 gave Y stress .

  • 25 (202) 234*4433 We're going to add them all together, and NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005*3701 www.nealrgross.com

822

  • 1 2

3 here's how much stress Vermont Yankee has experienced o v er the 35 years it has been operating.

is going on, or are these some sort Is that what of assumed 4 stresses that are theoretical?

5 MR. STEVENS: These are -- the transients 6 that we're calculating these stresses for are 7 specified by the designer, they are part of the design 8 basis, and they have been shown to be conservative --

9 very conservative definitions, compared to the actual 10 transients that Vermont Yankee --

11 JUDGE KARLIN: Yes, because here's where 12 I'm going. Let me just be real basic. Metal fatigue,

  • 13 14 15 I'm focusing on the NUREGs and the CUFens and that sort of thing, metal fatigue. As I metal fatigue -- you take a paper clip, it's made of

~nderstand it, 16 metal. You bend it once, twice, you bend it 100 times 17 and then it breaks. And you do this experiment a 18 dozen times and it breaks at a hundred.

19 with the hundredth bend, 90-degree bend, 20 it breaks. So now you know that that piece of metal 21 is going to break at the -hundredth twist of 90 22 degrees . That's my simplistic way of thinking about 23 this. This is the ASME curve that says at a hundred 24 breaks in air -~ bends at 90 degrees in air this paper

  • 25 clip will break.

(202) 234*4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005*3701 www.nealrgross.com

823

  • 1 Now you go and say, "All right. I've got 2 a paper clip here. I bent it 37 times. And I bent it 3 90 degrees some of those time s! a:-ld I bent it 45 4 degrees some o.f those times. I bent it 200 degrees 5 some of -- I bent it a lot of different ways . " And I ,

6 total up those 37 bends i and I say; "Okay. I have 7 used up this amount of stress." And if I -- and now 8 I know how long it is going to take fo~ me to get to 9 the hundredth time when it breaks. Is that what's 10 going on?

11 MR. STEVENS: That's simplistically what 12 is going on.

e 13 14 JUDGE KARLIN: And so when we are talking

. about the calculati6ns of the 20 transients, which are 15 bends, the times that there was stress imposed upon '

16 this, are you talking about the -- how we get to the 17 hundredth, the theoretical one hundred, or how do we 18 get to the actual history of this plant?

19 MR. STEVENS: The transient severity is 20 analogous to your how far did you bend your paper 21 clip?

22 JUDGE KARLIN: Right.

23 MR. STEVENS: Because if you bent your 24 paper clip 90 degrees and got 100 times until failure,

e. 25 you would get a different humber if you only bent your NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

(202) 234*4433 WASHINGTON, D .C. 20005*3701 www.nealrgross.com

8 24

  • 1 paper clip 45 degrees~

2 JUDGE KARLIN: Right .

3 MR. STEVENS: It's a measure of the load 4 on that component. These transients . all have 5 different severity . One transient may - have a 45-6 degree bend - analogy, another .one a 90-de~ree bend 7 analogy, anoth~r one a 10-degree bend analogy.

8 JUDGE KARLIN: Right.

9 MR. STEVENS: They all have different 10 severities. They are specified by the designer to be 11 very conservative, so that the designer can do a 12 fatigue design of the plant prior to construction.

  • 13 14 15 And those have been shown through numerous studies throughout the industry over the conservative, and those are the definitions that were history to be 16 used in the analyses for Vermont Yankee.

17 JUDGE KARLIN: So the American Society for 18 Mechanical Engineers and the people who designed this 19 particular boiling water reactor figur~d out for each 20 type of metal in that. reactor how many bends, how many 21 stresses it would take before it broke. Is that 22 right?

23 MR. STEVENS: Not quite.

24 JUDGE KARLIN: Okay.

  • 25 (202) 234-4433 MR. STEVENS: What they would do NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005*3701 1S an www.nealrgross .com

825

  • 1 2

3 ji II analysis In accordance with ASME code to demonstrate that for those loadings the component will not show unacceptable results. And in this particular case 4 that's a usage factor less than one.

5 JUDGE KARLIN: Right.

6 MR. STEVENS: That does not neces~arily 7 mean failure.

8 JUDGE KARLIN: Yes. So you have a hundred 9 if you had -- so the calculation is this thing will 10 -~ you can bend it a . hundred times 90 degrees and it 11 will break. Now, you've actually only bent it 70 12 times at 90 degrees, so your CUFen factor is .7,

  • 13 14 15 right?

MR. STEVENS:

JUDGE KARLIN:

That is correct.

And you've got 30 bends 16 left before it is going to break or before the 17 calculation says it will break, right?

18 MR. STEVENS: Well, again, the calculation 19 isn't indicating breakage. It's--

20 JUDGE KARLIN: Failure of some kind.

21 MR. STEVENS: -- the acceptance criteria 22 that's used, and there is margin on that ~cceptance 23 criteria.

24 JUDGE KARLIN: Okay. I understand.

  • 25 (202) 234-4433 MR. STEVENS: We work with safety factors NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005*3701 www.nealrgross.com

826 II

  • 1 2

3 and other things that prevent breakage.

digression.

JUDGE KARLIN:

.Go ahead.

Okay . Sorry for the 4 JUDGE REED: Please continue . .

5 MR. STEVENS: Back to our --we now have 6 our 20 transients linked together. I have made an 7 assumption in how those transients link together, the 8 order they occur. And what the ASME code tells us to 9 do as well, in order to capture the most conservative 10 order, we're going to go through this history and 11 we're going to take the largest extremes and say that 12 they define a stress fluctuation that the component

  • 13 14 15 will go through.

let's say So perhaps of this entire stress history the highest stress experienced was 16 transient 1, and the lowest stress was transient 18.

17 I would start by pairing those, and that would define 18 a stress range,' the maximum stress range that could be 19 conceivable for that component to see throughout that 20 stress history.

21 When I make that choice it is like taking 22 transient 18 and moving it next to transient 1, 23 assuming that order, adjacent order.

24 JUDGE REED: Well, aren't you,

  • 25 furthermore, assuming that these two transients occur (202) 234-4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 www.nealrgross.com

827

  • 1 2

3 with the same frequency?

thing and one is a weekly thing.

Suppose one .is an annual putting them together in your analysis when you know How do you justify 4 that one occurs 50* times more often than th~ other?

5 MR. STEVENS: That would be something I 6 would like to take adv antage of, because -- but this 7 way i~ conservative and it's making that assumption.

8 It is very bounding.

9 JUDGE REED: Okay. I understand that.

10 JUDGE WARDWELL: This is just defining the 11 angle at which y ou're bending the paper clip.

12 MR . STEVENS: It's trying to -- back to

  • 13 14 15 your paper clip analogy, it is trying to just say that based on the stress history, things in any order I wanted to, and if I could reorder the worst extreme 16 your paper clip may go through is 90 degrees, so I 17 want you to take that as the top cycle, the most 18 severe cycle to evaluate. But it's 19 JUDGE WARDWELL: The right paper clip 20 would --the fact that one transient occurs now and 21 another one occurs a week later isn't necessarily --

22 I'm trying to find a word that -- with a paper clip 23 you could bend it once, and then a week later bend it, 24 it's still going to know -- it's got a memory -- it's

  • 25 going to (202) 234*4433 know you have bent NEAL R. GROSS it.

COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 So it's not www.nealrgross .com

828

  • 1 completely unreas o nable to move 1 8 , because this is an 2 arbitra r y number, up next to the other one, becau s e 3 that range of stre sses ha s been felt by that metal.

4 MR . STEVENS: That's correct. But it 5 ignores that there could have been events in between 6 thos e t wo. But In principle

  • what you're saylng is 7 correct . .

8 JUDGE KARLIN: Why does it make any 9 difference, I mean, whether you put them together --

10 you ha ve had 37 events at this -- on this paper clip, 11 you know, of bending at different angles. I don't 12 care whether they are all done, what order they are

  • 13 14 15 done, at the end of the day 37 events have occurred, this much stress has occurred, and you have used up this amount of your CUFen before yo~ get to 1, right?

16 MR . STEVENS: If transient 15 actually 17 occurred after transient 1, and had a much smaller 18 stress associated with it than transient 18, then the 19 cycle the component saw on that day is much smaller 20 than the one I assumed by putting ~ransient 18 next to .

21 1.

22 JUDGE KARLIN: So you're assuming a 23- conservative assumption; the worst case as it were.

24 MR. STEVENS: It's the worst possible --

  • 25 (202) 234-4433 JUDGE KARLIN: Higher stress.

NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE.lSLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 So it would www.nealrgross.com

829

  • 1 2

3 be more fatigue ,

consumption of what a v ailable fatigue breaks or fails.

the what's available there is before it 4 JUDGE WARDWELL: I hate to beat this, but 5 180 degrees as opposed to 90 degrees is --

6 MR. STEVENS: That's a very good analogy, 7 yes.

8 JUDGE REED: So if we move on now, you've 9 taken and done this pairing, what do you do with all 10 of the other transients?

11 MR. STEVENS: Well, I go -- okay .

12 JUDGE REED: You pick the worst two, put

  • 13 14 15 together, and you put those together --

two .

MR. STEVENS: One occurrence of the worst 16 JUDGE REED: One occurrence.

17 MR. STEVENS: If you can . imagine now, 18 remember in the beginning I told you that each 19 transient has a specific number of occurrences 20 associated with it.

21 JUDGE REED: Yes.

22 MR. STEVENS: So, if you will, each peak 23 and valley of this long stress history --

24 JUDGE REED: Yes.

  • 25 (202) 234-4433 MR. STEVENS: -- has a number of cycles NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE ., N.W.

WASHINGTON , D.C. 20005-3701 www.nealrgross.com

830

  • 1 2

3 associated wi th transients.

and if my designer it that's equal to the number If I take the portion that's transient 1, '

said 100 of those could occur of 4 during the life of the plant, then that stress history 5 --every point on it -- could occur 100 times, almost 6 analogous to now I've got this third dimension kind of 7 on this graph. I've got a stress versus time history, 8 and each point has a different number of occurrences 9 associated with it the number of transients that 10 were spscified by the designer.

11 So if I take transient 1 and transient 18, 12 I have now taken one occurrence of each of those

  • 13 14 15 If I had 100 occurrences of transient 1, have 99 of those points left to deal with.

imagine, if I go through this history and take the So y6u can I

16 highest and the lowest, and cross one site -- one 17 occurrence of each of those off, and take the next 18 highest or the next lowest, and I repeat that process 19 until all occurrences of all transients have been 20 consumed, I'd get a nice stress array right from 21 largest stress range to lowest with the number of 22 occurrences next to it.

23 JUDGE REED: I see that.

24 JUDGE WARDWELL: So far, the three NUREGs

  • 25 of interest haven't even come into play yet, is that (202) 234-4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON, D.C. 20005-3701 www.nealrgross.com

831 I

  • 1 2

3 correct?

MR. STEVENS:

JUDGE WARm'JELL:

Yes.

This is all stress 4 analysis.

5 MR. STEVENS: . That's correct.

6 JUDGE KARLIN: So in that respect it's the 7 ASME code as opposed to the Fen part of the analysis?

8 MR. STEVENS: That's *correct.

9 JUDGE KARLIN: Okay.

10 MR. STEVENS: So now I have a spectrum of 11 stress range and cycles applied to that stress range.

12 So now I have what's required to calculate fatigue.

  • 13 14 _

15 I'll stop here for one --

JUDGE WARDWELL:

MR. STEVENS:

To calculate what?

Fatigue usage.

16 JUDGE WARDWELL: Fatigue.

17 MR. STEVENS: CUF.

18 JUDGE WARDWELL: CUF.

19 MR. STEVENS: Now, this represents 90, 95 20 percent of the work.

21 JUDGE WARDWELL: How long does it take to 22 do this -- person-hours, labor-hours?

23 MR. STEVENS: Just as an example, the 24 confirmatory calculations for Vermont Yankee feedwater

  • 25 nozzle took about three weeks dedicated. approximately (202) 234-4433 NEAL R. GROSS COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.w.

WASHINGTON, D.C. 20005-3701 www.nealrgross.com

832

  • 1 2

3 three individuals full-time.

JUDGE KARLIN:

confirmatory analysis for one nozzle, So let me understand.

the feedwater The 4 nozzle, took three people three weeks of work?

5 MR. STEVENS: That's correct.

6 JUDGE KARLIN: It took nine weeks of time, 7 nine 8 MR: STEVENS: Nine man-weeks.

9 JUDGE KARLIN: Nine man-weeks.

10 MR. STEVENS: You must understand that 11 that includes all the quali ty assurance checks and 12 documentation proper filing.

  • 13 14 15 them in four hours?

JUDGE KARLIN:

MR. STEVENS:

Well, how did you do all of No.

16 (Laughter. )

17 MR. STEVENS: This is the point I was 18 going to make. What's left took us four hours. So 19 I'll describe what's left next.

20 JUDGE WARDWELL: Before you do that, Dr.

21 Hopenfeld, is everything Mr. Stevens has said to date 22 your understanding of how they ~id it when you did 23 your review and filed your testimony?

24 DR. HOPENFELD: With respect to the

  • 25 specific numerical analysis, (202) 234*4433 NEAL R. GROSS I am not an expert in COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., N.W.

WASHINGTON, D.C. 20005*3701 www.nealrgross.com

833

  • 1 2

stress numerical analysis.

opinion.

JUDGE WARDWELL: I'm not asking y ou any I'm asking you whether or not, when you were 4 reviewing this for NEC and filed your testimony, . is 5 everything that Mr. Stevens said consistent with what 6 yo~thought they had done?

7 DR. HOPENFELD: Yes, yes.

8 JUDGE WARDWELL: That's all we need right 9 now.

10 DR. HOPENFELD: Oh, yes. I will 11 JUDGE WARDWELL: Thank you. Just want to 12 make sur e he hasn't told any --

  • l3 14 15 DR . HOPENFELD:

issue with what he said.

JUDGE WARDWELL:

Ev en now, I don't have any And there isn't a 16 misunderstanding --

17 DR. HOPENFELD: No, no, no. I have no --

18 I am absolutely in agreement with it.

19 JUDGE WARDWELL: So you don't contest -~

20 DR. HOPENFELD: No.

21 JUDGE WARDWELL: the basic approach 22 that they have said they did.

23 JUDGE KARLIN: And the answer to that is 24 -- Dr. Hopenfeld, you don't contest that approach .

  • 25 (202) 234-4433 DR . HOPENFELD:

NEAL R. GROSS I have -- no, COURT REPORTERS AND TRANSCRIBERS 1323 RHODE ISLAND AVE., NW.

WASHINGTON , D.C. 20005-3701 this has www.nealrgross .com