ULNRC-05933, Response to RAI to the 2011 Steam Generator Tube Inspection Report
| ML12325A171 | |
| Person / Time | |
|---|---|
| Site: | Callaway |
| Issue date: | 11/15/2012 |
| From: | Kremer G Ameren Missouri, Union Electric Co |
| To: | Office of Nuclear Reactor Regulation, Document Control Desk |
| References | |
| ULNRC-05933, TAC ME9087 | |
| Download: ML12325A171 (27) | |
Text
~rt.
WAmeren MISSOURI Callaway Plant November 15,2012 ULNRC-05933 u.s. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Ladies and Gentlemen:
DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.
FACILITY OPERATING LICENSE NPF-30 RESPONSE TO RAJ TO THE 2011 STEAM GENERATOR TUBE INSPECTION REPORT
References:
- 1. Ameren Missouri Letter ULNRC-05866, "Results of Steam Generator Tube In-service Inspection," dated May 17,2012
- 2. NRC Letter, "Callaway Plant, Unit 1 - Request for Additional Information Re: 2011 Steam Generator Tube Inspections (TAC No. ME9087)," dated October 18,2012 By the Reference 1 letter, Union Electric Company (Ameren Missouri) submitted infonnation summarizing the steam generator tube inspections perfonned at Callaway Plant, Unit 1, during Refueling Outage 18 in 2011. Reference 2 dated October 18,2012 transmitted a Request for Additional Infonnation (RAI) related to our report. Enalosures 1 and 2 hereby provide Ameren Missouri's response to the individual requests contained in the October 18, 2012 RAJ.
No new commitments are identified in this correspondence. None of the material in this report is considered proprietary by Union Electric.
If you have any questions or require additional infonnation, please contact Mr. Thomas Elwood, Supervising Engineer, Regulatory Affairs and Licensing at 314-225-1905.
EMP/nls Sincerely,
~75/~
GregoZ
- mer,
,,;. 5 iz'"
Manager, Engineering Programs PO Box 620 Fulton, MO 65251 AmerenMissouri.com
ULNRC-05933 November 15, 2012 Page 2
Enclosures:
- 1. Request For Additional Information (RAI) Responses
- 2. Anti-Vibration Bar (AVB) Wear Indications
ULNRC-05933 November 15,2012 Page 3 cc:
Mr. Elmo E. Collins Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Fred Lyon Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop 0-8B 1 Washington, DC 20555-2738
ULNRC-05933 November 15,2012 Page 4 Index and send hardcopy to QA File A160.0761 Hardcopy:
Certrec Corporation 4150 International Plaza Suite 820 Fort Worth, TX 76109 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)
Electronic distribution for the following can be made via Responses and Reports ULNRC Distribution:
A. C. Heflin F. M. Diya C. O. Reasoner III L. H. Graessle S. A. Maglio T. B. Elwood R. Holmes-Bobo NSRB Secretary Mr. Paul Parmenter, Director (SEMA)
Mr. Thomas Mohr, Senior REP Planner (SEMA)
Mr. Tom Masso, REP Planner (SEMA)
Mr. Bill Muilenburg (WCNOC)
Mr. Tim Hope (Luminant Power)
Mr. Ron Bames (APS)
Mr. Tom Baldwin (PG&E)
Mr. Mike Murray (STPNOC)
Ms. Linda Conklin (SCE)
Mr. John O'Neill (Pillsbury Winthrop Shaw Pittman LLP)
Mr. Dru Buntin (DNR) to ULNRC-05933 Page 1 CALLA WAY PLANT, UNIT 1 2011 STEAM GENERATOR TUBE INSPECTIONS ENCLOSURE 1 REQUEST FOR ADDITIONAL INFORMATION (RAI) RESPONSES to ULNRC-05933 Page 2 Question #1 Please discuss the results of your plug inspection. Regarding the secondary side inspections in the steam drum area of SG B and SG C, please discuss whether any degradation was identified.
Callaway Response Visual inspections were performed on the pre-existing welded plug in SG A (tube 13-109). No issues were noted.
Visual inspections were performed in the steam drum of SG B & SG C. No degradation was detected in either SG. The only anomaly noted was a buckled screen sector in SG B. Specifically, two buckles were noted on one of the loose-parts trapping screen sectors (the sector directly below the feedwater nozzle at the top of downcomer.) According to plant records, these two buckles were pre-existing and not new.
Question #2 On page 2 ofthe report, it is indicated that the X-probe was used to acquire data on both the hot-leg and cold-leg from the tube end to I-inch above the first tube support plate, in all four SGs. The report also states that the data would be analyzed for both hot-leg and cold-leg, from 3-inches below the top of the tubesheet to I-inch above the first support plate. Table 1 on page 3, however, indicates that only the hot-leg data was analyzed and that only data from 3 inches above to 3 inches below the top of the tube sheet was acquired. Please clarify.
Callaway Response Initial plans were to perform eddy current X-probe examinations on both the hot-leg and cold-leg in all four SGs. Due to unanticipated issues during the outage, cold leg examinations were cancelled in order to expedite outage schedule. AREV A Acquisition was required to run Array probes from the first Tube Support Plate (TSP) to tube end hot (OIH+ 1" to TEH); however AREVA Analysis Group only analyzed from the first TSP to the top of the tubesheet minus 3 inches (OIH+ 1" to TTSH-3"). The affected table is updated and included below:
Table 1 Eddy Current Testing Task Summary (Tubes Inspected)
ECTTask Extent S/GA S/GB S/GC S/GD Total Tubes 100% Bobbin Tube end hot to 5535 5536 5536 5536 22143 F/L tube end cold Array First TSP to TEH 965 965 965 965 3860 H/L (OlH+ 1" to TEH)
Special Specified 90 61 76 35 262 Interest +Point location FIL = Full Length HIL = Hot Leg (no cold leg array performed) to ULNRC-05933 Page 3 Question #3 Please provide descriptions of the following acronyms: IDC and SPT.
Callaway Response IDC is inside diameter chatter. Chatter signals can occur in a tube at any location and typically appear as uniform horizontal noise signals.
SPT stands for "support" and is the code used to identify wear from the anti-vibration bar (A VB) bundle supports or positioning devices. It is also referred to as V -shaped support pads or "Appui".
Question #4 For the 20 percent random sample of dings that were performed on each SG, please provide the minimum voltage threshold used for screening.
Callaway Response The reporting threshold for dings (DNG) was >=2.0 volts. Any previously reported DNG >=1.0 volt was required to be reported again. In order to have sufficient DNG population to inspect with a rotating pancake coil (RPC), a minimum voltage of 1.0 volt was used if the applicable SG did not have enough 2.0 volt DNGs. A summary of each SG is as follows:
SG-A SG-B SG-C SG-D Question #5 NoDNGs Enough 2.0 volt DNGs DNGs >=2.0 volts and DNGs between 1-2 volts sampled DNGs >=2.0 volts and DNGs between 1-2 volts sampled Please clarify the nature of the 33 miss-drilled tubes (e.g., size, location).
Callaway Response The 33 tubes identified in the Table below had been identified as having non-nominal tube sheet drill hole diameters. All tubes were inspected with +Point' during the pre-service inspection (PSI) which did not detect any degradation. A random 20% sample was inspected during Refueling Outage 18 using both +Point' and Array which is required per EPRI SG Examination Guidelines. No degradation was detected.
to ULNRC-05933 Page 4 Steam Generator SGA SGB SGC SGD Table 2 Miss-drilled tubes Row Column 43 75 43 91 52 30 52 36 52 42 15 45 15 49 15 63 40 12 41 11 41 25 79 111 61 101 82 50 19 123 31 61 31 63 31 77 39 49 47 109 56 120 19 11 35 97 35 113 65 39 69 33 71 59 73 83 73 97 73 99 24 124 25 25 73 41 Leg Hot Hot Hot Hot Hot Cold Cold Cold Cold Cold Cold Cold Hot Hot Hot Hot Hot Hot Hot Hot Hot Hot Hot Hot Hot Hot Hot Hot Hot Hot Cold Cold COld to ULNRC-05933 Page 5 Question #6 The text below Table 3 indicates that the maximum reported axial length was 0.59 inches and the maximum reported circumferential extent was 48 degrees. Please verify these numbers, as Table 3 is noted to contain an axial length and circumferential extent greater than these values.
Callaway Response The text located under Table 3 contained an error. Table 3 is correct and accurately reflects the maximum circumferential extent as 56 degrees and the maximum axial length as 0.81 inches.
Question #7 Table 3 provides a listing of tube support plate wear indications; please provide a similar table for all anti-vibration bar indications.
Callaway Response All tube support plate (TSP) wear was inspected with RPC to acquire axial and circumferential measurements. All TSP wear identified was new and it is noted that there were fewer TSP indications than A VB wear. Enclosure 2 summarizes the following for A VB wear in all 4 SGs:
SG, Row, Column, Location, current percent through wall (% TH), and previous % TW if any Question #8 There appears to be a significant increase in the number of wear indications at the tube supports and anti-vibration bars. Please discuss any insights for these increases. Please discuss whether the growth rates of these indications have increased or decreased.
Callaway Response A total of 623 bobbin probe wear indications (589 A VB wear and 34 TSP wear) were detected during Refueling Outage 18. Of these, 531 indications were new (497 AVB wear and 34 TSP wear). The number of indications and maximum percent through wall (TW%) has increased since the first in-service inspection (lSI). This is expected when comparing three cycles of operation to only one cycle.
The A VB wear growth rates are shown to be decreasing from the last inspection by about 50%.
Additionally, the growth rates for A VB wear bound the growth rates associated with TSP wear which show TSP wear growth rates less than 5%TW per EFPY.
to ULNRC-05933 Page 1 ENCLOSURE 2 ANTI-VIBRATION BAR (AVB) WEAR INDICATIONS to ULNRC-05933 Page 2 Anti-Vibration Bar (A VB) Wear Indications Question #7 requested a table for anti-vibration bar indications. Tables 1 through 4 present the A VB wear indications for all four SGs.
Table 1 SG A A VB Wear Indications Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGA 94 86 TWO AV3
-0.04 5
SGA 58 68 TWO AV2
-0.04 6
SGA 92 64 TWO AV1 0
6 SGA 97 81 TWO AV1
-0.15 6
SGA 98 76 TWO AV2
-0.09 6
SGA 71 89 TWO AV3
-0.02 6
SGA 85 75 TWO AV5
-0.09 6
SGA 75 83 TWO AV2 0.02 6
SGA 95 65 TWO AV5
-0.13 6
SGA 76 68 TWO AV1 0.04 6
SGA 85 65 TWO AV6 0.05 6
SGA 92 78 TWO AV2
-0.04 6
SGA 84 78 TWO AV2
-0.09 6
SGA 78 88 TWO AV5
-0.02 6
SGA 80 80 TWO AV4
-0.04 6
SGA 86 84 TWO AV2
-0.02 6
SGA 85 81 TWO AV2
-0.02 7
SGA 69 51 TWO AV4 0.09 7
SGA 109 69 TWO AV4
-0.09 7
SGA 73 69 TWO AV3
-0.07 7
SGA 85 71 TWO AV5
-0.02 7
SGA 98 68 TWO AV4
-0.09 7
SGA 86 84 TWO AV4
-0.07 7
SGA 94 86 TWO AV5
-0.02 7
SGA 85 71 TWO AV1
-0.02 7
SGA 93 69 TWO AV3
-0.11 7
SGA 108 74 TWO AV6
-0.04 7
SGA 109 69 TWO AV2
-0.04 7
SGA 93 65 TWO AV2
-0.04 7
SGA 92 72 TWO AV5
-0.04 7
SGA 92 78 TWO AV3
-0.04 7
SGA 93 73 TWO AV4 0.04 7
to ULNRC-05933 Page 3 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGA 93 73 TWO AV3
-0.02 7
SGA 58 32 TWO AV6 0.02 7
SGA 108 74 TWO AV2 0.02 7
SGA 80 80 TWO AV3 0.02 7
SGA 102 66 TWO AV6
-0.07 7
SGA 108 74 TWO AV3
-0.13 8
SGA 71 79 TWO AV4 0.02 8
SGA 77 77 TWO AV3 0.02 8
SGA 110 68 TWO AV1
-0.04 8
SGA 96 66 TWO AV1 0.02 8
SGA 106 72 TWO AV6
-0.13 8
SGA 94 86 TWO AV6
-0.07 8
SGA 79 49 TWO AV2
-0.04 8
SGA 83 67 TWO AV4 0.04 8
SGA 84 82 TWO AV2
-0.02 8
SGA 79 47 TWO AV4
-0.04 8
SGA 93 55 TWO AV4
-0.02 8
SGA 108 68 TWO AV2
-0.07 8
SGA 87 79 TWO AV4 0
8 SGA 85 75 TWO AV2
-0.09 8
SGA 111 73 TWO AV4
-0.09 8
SGA 54 14 TWO AV1 0.02 9
SGA 75 63 TWO AV3
-0.09 9
SGA 98 66 TWO AV1
-0.09 5.00 9
SGA 88 66 TWO AV3 0.02 9
SGA 109 67 TWO AV1
-0.02 9
SGA 74 96 TWO AV4 0
9 SGA 111 65 TWO AV6 0.07 9
SGA 93 65 TWO AV5
-0.07 9
SGA 95 73 TWO AV3
-0.04 9
SGA 109 67 TWO AV4
-0.07 9
SGA 74 96 TWO AV3
-0.04 10 SGA 108 74 TWO AV1
-0.02 10 SGA 77 51 TWO AV5
-0.11 10 SGA 99 65 TWO AV6 0.02 10 SGA 85 71 TWO AV6
-0.09 10 SGA 111 63 TWO AV2
-0.11 5.00 10 SGA 83 63 TWO AV5
-0.02 10 to ULNRC-05933 Page 4 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGA 102 66 TWO AV5 0.11 10 SGA 58 68 TWO AV4
-0.13 10 SGA 93 69 TWO AV6
-0.09 10 SGA 104 64 TWO AV5
-0.15 10 SGA 85 77 TWO AV5 0
10 SGA 98 84 TWO AV3
-0.09 11 SGA 84 82 TWO AV3
-0.07 11 SGA 77 77 TWO AV5
-0.02 11 SGA 85 63 TWO AV6
-0.04 11 SGA 104 64 TWO AV6
-0.02 3.00 11 SGA 109 61 TWO AV5
-0.02 11 SGA 93 65 TWO AV4 0
11 SGA 88 68 TWO AV3 0
11 SGA 58 68 TWO AV3
-0.07 11 SGA 92 82 TWO AV3
-0.02 12 SGA 85 85 TWO AV3 0
12 SGA 78 88 TWO AV4
-0.02 12 SGA 73 41 TWO AV3 0.04 12 SGA 69 43 TWO AV4
-0.04 12 SGA 96 70 TWO AV5
-0.02 12 SGA 77 51 TWO AV2
-0.02 12 SGA 85 65 TWO AV5
-0.04 12 SGA 75 83 TWO AV3
-0.04 13 SGA 108 68 TWO AV4
-0.02 13 SGA 95 73 TWO AV2
-0.04 13 SGA 92 64 TWO AV5
-0.04 13 SGA 60 64 TWO AV5
-0.02 13 SGA 85 65 TWO AV3
-0.02 13 SGA 75 83 TWO AV4
-0.04 13 SGA 86 84 TWO AV3
-0.04 14 SGA 79 47 TWD AV3
-0.04 14 SGA 85 81 TWD AV3
-0.07 14 SGA 107 65 TWO AV5
-0.02 4.00 14 SGA 107 65 TWD AV1
-0.15 9.00 14 SGA 87 79 TWD AV3
-0.02 14 SGA 77 77 TWD AV4
-0.04 14 SGA 98 84 TWO AV2
-0.04 14 SGA 111 73 TWD AV5 0
14 to ULNRC-05933 Page 5 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGA 75 83 TWO AV5
-0.07 14 SGA 76 68 TWO AV4
-0.02 14 SGA 82 76 TWO AV4
-0.02 15 SGA 109 67 TWO AV6
-0.02 15 SGA 92 72 TWO AV4
-0.02 15 SGA 85 65 TWO AV2 0.04 15 SGA 96 66 TWO AV5
-0.04 15 SGA 77 51 TWO AV4 0.02 8.00 15 SGA 98 68 TWO AV5 0
15 SGA 99 65 TWO AV5
-0.02 15 SGA 81 85 TWO AV4
-0.04 15 SGA 99 67 TWO AV6
-0.04 15 SGA 108 68 TWO AV3
-0.02 16 SGA 71 79 TWO AV3
-0.04 16 SGA 99 67 TWO AV1
-0.02 3.00 16 SGA 69 43 TWO AV3
-0.02 17 SGA 93 65 TWO AV3 0
17 SGA 76 68 TWO AV3 0.04 17 SGA 85 77 TWO AV2
-0.09 17 SGA 85 71 TWO AV4
-0.09 17 SGA 98 66 TWO AV5
-0.04 17 SGA 109 61 TWO AV6
-0.18 8.00 18 SGA 58 68 TWO AV5 0
18 SGA 81 85 TWO AV2 0.04 18 SGA 78 76 TWO AV2 0.04 8.00 18 SGA 77 51 TWO AV3
-0.02 6.00 19 SGA 83 67 TWO AV2
-0.07 19 SGA 108 74 TWO AV4 0
19 SGA 111 73 TWO AV3
-0.11 19 SGA 78 76 TWO AV5
-0.02 20 SGA 109 67 TWO AV5 0.04 20 SGA 110 68 TWO AV2
-0.13 6.00 20 SGA 110 68 TWO AV4 0.04 20 SGA 83 67 TWO AV3
-0.09 21 SGA 92 82 TWO AV5
-0.02 21 SGA 76 68 TWO AV5 0
21 SGA 82 76 TWO AV3
-0.02 21 SGA 108 74 TWO AV5 0
21 to ULNRC-05933 Page 6 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGA 92 64 TWO AV3
-0.02 21 SGA 110 68 TWO AV3
-0.09 6.00 22 SGA 92 64 TWO AV4 0
22 SGA 92 64 TWO AV2
-0.07 22 SGA 81 85 TWO AV3
-0.04 22 SGA 109 67 TWO AV3 0
22 SGA 111 73 TWO AV2
-0.13 22 SGA 111 73 TWO AV6 0.04 22 SGA 96 66 TWO AV2
-0.04 23 SGA 107 65 TWO AV4
-0.09 6.00 23 SGA 107 65 TWO AV2
-0.04 11.00 23 SGA 109 67 TWO AV2
-0.13 24 SGA 99 67 TWO AV5
-0.04 8.00 24 SGA 92 72 TWO AV3
-0.04 24 SGA 78 76 TWO AV4 0
26 SGA 85 63 TWO AV2
-0.11 14.00 27 SGA 85 71 TWO AV2
-0.09 27 SGA 96 66 TWO AV4
-0.02 5.00 27 SGA 99 67 TWO AV4 0.04 3.00 28 SGA 98 66 TWO AV2
-0.04 8.00 28 SGA 92 82 TWO AV4 0
8.00 28 SGA 85 77 TWO AV3
-0.09 28 SGA 85 71 TWO AV3
-0.09 28 SGA 85 63 TWO AV3
-0.02 12.00 28 SGA 76 68 TWO AV2
-0.02 28 SGA 98 66 TWO AV4
-0.07 7.00 28 SGA 78 76 TWO AV3
-0.04 12.00 29 SGA 96 66 TWO AV3
-0.02 8.00 29 SGA 107 65 TWO AV3
-0.09 14.00 30 SGA 99 67 TWO AV2
-0.11 6.00 32 SGA 98 66 TWO AV3
-0.07 12.00 33 SGA 85 63 TWO AV4 0.02 17.00 34 SGA 85 63 TWO AV5
-0.04 12.00 34 SGA 99 67 TWO AV3
-0.04 8.00 35 to ULNRC-05933 Page 7 Table 2 SG B A VB Wear Indications Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGB 111 71 TWO AV3 0
5 SGB 65 67 TWO AV3
-0.07 5
SGB 83 75 TWO AV5 0.07 6
SGB 52 76 TWO AV4
-0.15 6
SGB 86 68 TWO AV2
-0.04 6
SGB 65 67 TWO AV2
-0.09 6
SGB 111 71 TWO AV2
-0.02 6
SGB 88 78 TWO AV2 0
6 SGB 90 68 TWO AV4
-0.07 6
SGB 76 74 TWO AV3 0
6 SGB 100 58 TWO AV5 0.04 7
SGB 85 77 TWO AV4 0
7 SGB 97 81 TWO AV3 0
7 SGB 65 67 TWO AV5 0.04 7
SGB 83 75 TWO AV4 0
8 SGB 88 88 TWO AV2 0
8 SGB 88 70 TWO AV6
-0.13 4.00 8
SGB 61 67 TWO AV2
-0.02 8
SGB 97 69 TWO AV4
-0.13 8
SGB 95 69 TWO AV4
-0.02 9
SGB 97 55 TWO AV2
-0.02 9
SGB 76 74 TWO AV4
-0.11 9
SGB 89 63 TWO AV4
-0.09 9
SGB 82 74 TWO AV3 0.04 9
SGB 83 75 TWO AV2 0.04 9
SGB 80 66 TWO AV3 0
9 SGB 95 69 TWO AV3
-0.11 9
SGB 90 68 TWO AV3
-0.02 9
SGB 77 73 TWO AV2
-0.11 10 SGB 95 79 TWO AV6
-0.07 10 SGB 61 77 TWO AV3 0
10 SGB 89 63 TWO AV5 0.04 10 SGB 95 57 TWO AV5
-0.09 10 SGB 103 67 TWO AV4 0
10 SGB 84 56 TWO AV4 0.04 10 to ULNRC-05933 Page 8 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGB 91 65 TWO AV5
-0.02 10 SGB 91 65 TWO AV1 0.02 10 SGB 81 67 TWO AV5
-0.02 11 SGB 86 64 TWO AV5
-0.04 11 SGB 85 77 TWO AV2 0
11 SGB 95 79 TWO AV2 0
11 SGB 98 72 TWO AV5 0.04 11 SGB 68 58 TWO AV3
-0.02 11 SGB 97 81 TWO AV4
-0.02 11 SGB 84 56 TWO AV3 0.04 11 SGB 88 78 TWO AV6
-0.04 11 SGB 90 60 TWO AV4
-0.09 11 SGB 77 73 TWO AV4
-0.09 12 SGB 82 66 TWO AV2
-0.07 13 SGB 95 57 TWO AV3
-0.02 13 SGB 85 77 TWO AV3
-0.11 13 SGB 83 75 TWO AV3
-0.02 13 SGB 82 74 TWO AV4
-0.07 13 SGB 78 66 TWO AV5
-0.04 13 SGB 77 67 TWO AV3
-0.02 13 SGB 97 69 TWO AV2
-0.11 13 SGB 76 68 TWO AV5
-0.02 13 SGB 76 68 TWO AV6
-0.04 13 SGB 88 88 TWO AV3
-0.02 13 SGB 78 66 TWO AV6 0.05 13 SGB 86 68 TWO AV6
-0.07 14 SGB 77 87 TWO AV2
-0.02 14 SGB 75 51 TWO AV3
-0.07 14 SGB 89 63 TWO AV2
-0.02 15 SGB 68 58 TWO AV4 0
15 SGB 98 70 TWO AV6
-0.02 15 SGB 95 79 TWO AV5
-0.02 15 SGB 77 67 TWO AV6
-0.09 15 SGB 90 60 TWO AV2
-0.07 15 SGB 77 87 TWO AV3 0
16 SGB 88 70 TWO AV1
-0.09 8.00 16 SGB 95 79 TWO AV3
-0.07 16 SGB 86 64 TWO AV4
-0.09 16 to ULNRC-05933 Page 9 Prev 5G Row Col Ind 5u~~
Inch1
%TW
%TW 5GB 84 72 TWO AV3
-0.22 16 5GB 98 70 TWO AV2
-0.02 16 5GB 82 66 TWO AV5
-0.04 17 5GB 77 67 TWO AV4 0.02 17 5GB 77 87 TWO AV4 0
17 5GB 88 78 TWO AV5 0.04 17 5GB 90 60 TWO AV3 0.04 19 5GB 81 67 TWO AV4 0
19 5GB 86 64 TWO AV3
-0.04 21 5GB 88 88 TWO AV4
-0.02 21 5GB 77 73 TWO AV3
-0.04 21 5GB 81 67 TWO AV3
-0.07 22 5GB 76 68 TWO AV4
-0.07 22 5GB 97 69 TWO AV3
-0.07 22 5GB 89 63 TWO AV3
-0.02 22 5GB 88 70 TWO AV2 0.07 9.00 23 5GB 76 68 TWO AV3
-0.11 23 5GB 76 68 TWO AV2 0
23 5GB 78 66 TWO AV3
-0.04 23 5GB 95 57 TWO AV4
-0.07 24 5GB 88 70 TWO AV5 0.04 8.00 24 5GB 86 68 TWO AV4 0
24 5GB 98 70 TWO AV5 0
24 5GB 88 78 TWO AV4 0.04 12.00 24 5GB 86 68 TWO AV5 0
24 5GB 88 70 TWO AV4
-0.15 7.00 26 5GB 88 78 TWO AV3 0
10.00 26 5GB 91 65 TWO AV2
-0.04 7.00 27 5GB 86 68 TWO AV3
-0.02 27 5GB 91 65 TWO AV4
-0.07 9.00 29 5GB 98 70 TWO AV4
-0.02 30 5GB 82 66 TWO AV3
-0.04 30 5GB 98 70 TWO AV3
-0.02 31 5GB 88 70 TWO AV3
-0.2 13.00 33 5GB 91 65 TWO AV3
-0.04 16.00 37 to ULNRC-05933 Page 10 Table 3 SG C A VB Wear Indications Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGC 73 67 TWO AV2
-0.02 5
SGC 100 72 TWO AV2
-0.09 5
SGC 63 39 TWO AV4
-0.09 5
SGC 90 72 TWO AV6
-0.04 5
SGC 81 59 TWO AV4
-0.04 5
SGC 62 64 TWO AV2
-0.11 5
SGC 98 68 TWO AV5
-0.02 6
SGC 78 66 TWO AV4 0.15 6
SGC 62 64 TWO AV4
-0.07 6
SGC 95 63 TWO AV3
-0.09 6
SGC 60 120 TWO AV3
-0.02 6
SGC 96 70 TWO AV5
-0.13 6
SGC 77 91 TWO AV5 0
6 SGC 89 61 TWO AV1 0
6 SGC 77 67 TWO AV4
-0.07 6
SGC 64 80 TWO AV3 0
6 SGC 81 79 TWO AV6
-0.22 6
SGC 101 69 TWO AV4
-0.02 6
SGC 94 72 TWO AV5 0.02 6
SGC 80 60 TWO AV5
-0.07 6
SGC 80 70 TWO AV4 0.04 6
SGC 84 88 TWO AV2
-0.11 6
SGC 91 69 TWO AV6 0.02 6
SGC 111 67 TWO AV3
-0.07 6
SGC 100 74 TWO AV1 0.13 6
SGC 77 81 TWO AV3 0.07 6
SGC 77 67 TWO AV2
-0.07 6
SGC 104 72 TWO AV5 0.04 7
SGC 59 103 TWO AV4
-0.13 7
SGC 107 69 TWO AV4
-0.02 7
SGC 82 62 TWO AV3
-0.02 7
SGC 59 103 TWO AV5
-0.04 7
SGC 77 91 TWO AV4 0.04 7
SGC 49 39 TWO AV1 0
7 SGC 76 70 TWO AV2
-0.18 7
to ULNRC-05933 Page 11 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGC 110 70 TWO AV4 0.04 7
SGC 83 75 TWO AV5
-0.02 7
SGC 94 66 TWO AV2 0.09 7
SGC 62 64 TWO AV5
-0.04 7
SGC 106 76 TWO AV2
-0.02 7
SGC 95 73 TWO AV2
-0.04 7
SGC 82 40 TWO AV3
-0.04 7
SGC 79 51 TWO AV2
-0.07 7
SGC 94 66 TWO AV4
-0.02 7
SGC 80 70 TWO AV3
-0.07 7
SGC 85 69 TWO AV3
-0.02 7
SGC 84 76 TWO AV4
-0.02 7
SGC 83 73 TWO AV5
-0.16 7
SGC 84 88 TWO AV4
-0.02 7
SGC 99 73 TWO AV3
-0.09 7
SGC 93 71 TWO AV2
-0.04 7
SGC 89 63 TWO AV4 0
8 SGC 108 72 TWO AV6 0.05 8
SGC 105 71 TWO AV4
-0.07 8
SGC 105 71 TWO AV3
-0.04 8
SGC 93 65 TWO AV1 0
6.00 8
SGC 93 71 TWO AV6
-0.02 8
SGC 80 60 TWO AV2
-0.04 8
SGC 81 77 TWO AV5 0
7.00 8
SGC 93 73 TWO AV5 0
8 SGC 102 74 TWO AV5 0.04 8
SGC 93 75 TWO AV5 0
8 SGC 97 67 TWO AV4
-0.04 8
SGC 73 67 TWO AV4
-0.07 8
SGC 69 35 TWO AV4
-0.04 8
SGC 91 73 TWO AV2 0
8 SGC 94 66 TWO AV3
-0.04 8
SGC 99 73 TWO AV4 0
8 SGC 84 74 TWO AV3 0
8 SGC 111 71 TWO AV5 0.04 8
SGC 58 44 TWO AV2
-0.07 8
SGC 97 83 TWO AV4
-0.31 8
SGC 67 65 TWO AV2 0.02 8
to ULNRC-05933 Page 12 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGC 110 72 TWO AV5 0.11 8
SGC 84 64 TWO AV4
-0.07 8
SGC 90 76 TWO AV2
-0.04 8
SGC 100 72 TWO AV4 0
8 SGC 95 65 TWO AV2
-0.04 8
SGC 83 57 TWO AV3
-0.07 8
SGC 111 67 TWO AV4
-0.07 8
SGC 89 63 TWO AV3
-0.04 9
SGC 90 72 TWO AV2
-0.07 9
SGC 101 63 TWO AV5
-0.02 9
SGC 81 59 TWO AV3
-0.02 9
SGC 77 71 TWO AV5
-0.04 9
t-SGC 107 69 TWO AV6 0
9 SGC 49 39 TWO AV2 0
9 SGC 93 69 TWO AV2
-0.04 9
SGC 64 80 TWO AV4
-0.29 9
SGC 97 73 TWO AV6
-0.02 9
SGC 89 67 TWO AV3
-0.09 9
SGC 97 69 TWO AV6 0
9 SGC 83 71 TWO AV2
-0.07 9
SGC 96 64 TWO AV2
-0.02 9
SGC 89 69 TWO AV4
-0.04 9
SGC 97 67 TWO AV3
-0.07 9
SGC 68 58 TWO AV5
-0.07 9
SGC 88 70 TWO AV5
-0.16 10 SGC 90 72 TWO AV3
-0.02 10 SGC 73 79 TWO AV2
-0.02 10 SGC 68 58 TWO AV4
-0.04 10 SGC 111 71 TWO AV6 0.04 10 SGC 77 91 TWO AV3 0.04 10 SGC 89 75 TWO AV5 0
10 SGC 96 70 TWO AV1 0
10 SGC 107 69 TWO AV5
-0.02 10 SGC 91 75 TWO AV4
-0.07 10 SGC 89 65 TWO AV3 0.04 11 SGC 84 88 TWO AV3 0.04 11 SGC 73 63 TWO AV4
-0.02 11 SGC 81 77 TWO AV4
-0.02 11 to ULNRC-05933 Page 13 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGC 83 61 TWO AV3
-0.04 11 SGC 104 82 TWO AV4 0
11 SGC 77 71 TWO AV4 0
11 SGC 97 67 TWO AV2
-0.11 11 SGC 89 69 TWO AV2
-0.09 11 SGC 83 67 TWO AV4 0
11 SGC 87 83 TWO AV3
-0.09 11 SGC 64 62 TWO AV3
-0.07 11 SGC 95 65 TWO AV3
-0.02 11 SGC 99 73 TWO AV2
-0.09 11 SGC 58 44 TWO AV3
-0.09 12 SGC 95 65 TWO AV4 0
12 SGC 97 63 TWO AV5
-0.04 12 SGC 64 62 TWO AV4
-0.09 12 SGC 97 71 TWO AV5
-0.04 12 SGC 97 71 TWO AV2
-0.07 12 SGC 90 72 TWO AV5
-0.02 6.00 12 SGC 100 72 TWO AV3 0
12 SGC 104 74 TWO AV4 0
12 SGC 79 51 TWO AV4
-0.02 12 SGC 95 65 TWO AV5
-0.11 12 SGC 91 75 TWO AV5
-0.07 12 SGC 83 67 TWO AV2
-0.04 12 SGC 102 74 TWO AV6
-0.04 12 SGC 73 63 TWO AV3
-0.02 12 SGC 83 61 TWO AV2
-0.04 13 SGC 80 70 TWO AV2
-0.07 13 SGC 91 51 TWO AV4 0
13 SGC 91 71 TWO AV6 0
13 SGC 84 64 TWO AV3
-0.02 13 SGC 58 44 TWO AV5
-0.04 13 SGC 98 68 TWO AV3
-0.02 13 SGC 93 75 TWO AV3
-0.07 13 SGC 97 61 TWO AV2
-0.07 13 SGC 101 63 TWO AV4
-0.02 13 SGC 87 71 TWO AV5 0
13 SGC 80 70 TWO AV5
-0.07 13 SGC 87 71 TWO AV3 0
14 to ULNRC-05933 Page 14 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGC 91 75 TWO AV6
-0.02 14 SGC 78 66 TWO AV3
-0.04 14 SGC 110 70 TWO AV3 0.04 14 SGC 77 81 TWO AV2
-0.11 14 SGC 89 67 TWO AV4 0.04 14 SGC 89 69 TWO AV3
-0.02 14 SGC 96 58 TWO AV2
-0.02 9.00 14 SGC 91 67 TWO AV4
-0.02 14 SGC 73 67 TWO AV3
-0.04 14 SGC 73 79 TWO AV6
-0.18 14 SGC 96 70 TWO AV4 0
15 SGC 99 73 TWO AV5 0
15 SGC 96 74 TWO AV5 0
15 SGC 96 66 TWO AV2 0.07 15 SGC 93 65 TWO AV3 0
11.00 15 SGC 89 75 TWO AV4
-0.07 15 SGC 91 71 TWO AV5 0
8.00 15 SGC 78 66 TWO AV2 0
15 SGC 87 83 TWO AV4
-0.07 16 SGC 96 64 TWO AV3
-0.02 16 SGC 97 69 TWO AV4 0
16 SGC 83 67 TWO AV3
-0.04 16 SGC 91 73 TWO AV3 0
16 SGC 77 67 TWO AV3 0.02 16 SGC 93 71 TWO AV5
-0.04 16 SGC 110 72 TWO AV6 0
16 SGC 101 69 TWO AV6 0.02 16 SGC 108 72 TWO AV3 0.04 16 SGC 89 67 TWO AV5
-0.04 17 SGC 100 74 TWO AV4 0
7.00 17 SGC 91 51 TWO AV2 0
17 SGC 90 56 TWO AV2 0
17 SGC 101 69 TWO AV5
-0.07 17 SGC 98 68 TWO AV2
-0.04 17 SGC 93 69 TWO AV4
-0.02 17 SGC 73 63 TWO AV5
-0.04 17 SGC 91 51 TWO AV3 0
18 SGC 80 60 TWO AV4
-0.04 18 to ULNRC-05933 Page 15 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGC 93 69 TWD AV5
-0.04 18 SGC 96 64 TWD AV5
-0.11 18 SGC 84 76 TWD AV2
-0.09 8.00 18 SGC 91 69 TWD AV2
-0.02 18 SGC 97 69 TWD AV5
-0.02 18 SGC 81 51 TWD AV3 0.02 9.00 19 SGC 96 74 TWD AV3 0
19 SGC 79 51 TWD AV3
-0.04 19 SGC 91 69 TWD AV4 0
19 SGC 96 66 TWD AV5
-0.04 20 SGC 90 56 TWD AV3
-0.04 20 SGC 96 74 TWD AV2 0
7.00 20 SGC 89 71 TWD AV2 0
20 SGC 93 65 TWD AV2
-0.02 9.00 20 SGC 81 51 TWD AV5
-0.07 7.00 21 SGC 89 75 TWD AV3 0
21 SGC 81 51 TWD AV4
-0.11 9.00 21 SGC 108 72 TWD AV5 0.07 21 SGC 95 73 TWD AV6 0
6.00 21 SGC 81 79 TWD AV5
-0.02 21 SGC 80 60 TWD AV3 0
22 SGC 103 67 TWD AV2
-0.04 7.00 22 SGC 89 61 TWD AV6
-0.02 9.00 22 SGC 100 74 TWD AV2 0
10.00 22 SGC 108 72 TWD AV4 0.07 22 SGC 97 61 TWD AV5
-0.07 22 SGC 96 64 TWD AV4
-0.02 23 SGC 81 77 TWD AV3 0
7.00 23 SGC 101 69 TWD AV3
-0.02 23 SGC 89 71 TWD AV4
-0.02 7.00 23 SGC 97 63 TWD AV4
-0.04 23 SGC 93 71 TWD AV4 0
6.00 23 SGC 101 69 TWD AV2
-0.09 24 SGC 96 70 TWD AV2
-0.04 24 SGC 73 79 TWD AV3
-0.11 24 SGC 96 66 TWD AV4
-0.02 24 SGC 103 67 TWD AV5 0
7.00 25 SGC 89 71 TWD AV5
-0.04 9.00 25 to ULNRC-05933 Page 16 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGC 95 73 TWO AV4 0
6.00 25 SGC 98 68 TWO AV4 0
25 SGC 96 58 TWO AV4
-0.02 10.00 25 SGC 100 74 TWO AV3 0
9.00 26 SGC 81 77 TWO AV2 0
10.00 26 SGC 95 73 TWO AV3 0
7.00 26 SGC 84 76 TWO AV3
-0.02 11.00 26 SGC 81 79 TWO AV4 0.04 26 SGC 97 71 TWO AV4
-0.04 6.00 26 SGC 93 69 TWO AV3
-0.04 26 SGC 96 70 TWO AV3 0
26 SGC 95 73 TWO AV5 0
7.00 27 SGC 73 79 TWO AV5
-0.09 27 SGC 77 71 TWO AV3
-0.04 9.00 27 SGC 97 61 TWO AV4
-0.02 27 SGC 96 66 TWO AV3 0
28 SGC 93 71 TWO AV3
-0.07 8.00 28 SGC 91 69 TWO AV5
-0.04 28 SGC 73 79 TWO AV4
-0.11 29 SGC 97 61 TWO AV3
-0.02 30 SGC 91 69 TWO AV3
-0.04 31 SGC 97 71 TWO AV3
-0.11 11.00 32 SGC 96 58 TWO AV3 0
15.00 32 SGC 89 61 TWO AV5
-0.04 12.00 32 SGC 89 71 TWO AV3
-0.09.
11.00 33 SGC 81 79 TWO AV3 0.07 10.00 33 SGC 89 61 TWO AV2
-0.04 15.00 34 SGC 89 61 TWO AV4 0
15.00 35 SGC 89 61 TWO AV3
-0.02 15.00 35 SGC 103 67 TWO AV3
-0.02 11.00 36 SGC 103 67 TWO AV4 0.02 20.00 39 to ULNRC-05933 Page 17 Table 4 SG D A VB Wear Indications Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGO 63 19 TWO AV3
-0.15 6
SGO 65 63 TWO AV4
-0.13 6
SGO 86 72 TWO AV5 0
6 SGO 98 66 TWO AV6 0
6 SGO 77 73 TWO AV4 0.07 6
SGO 99 71 TWO AV3 0
6 SGO 98 66 TWO AV2
-0.02 7
SGO 78 68 TWO AV6
-0.15 6.00 7
SGO 86 72 TWO AV3 0
7 SGO 76 60 TWO AV6 0
7 SGO 70 54 TWO AV4
-0.07 7
SGO 96 66 TWO AV3
-0.07 7
SGO 88 60 TWO AV4
-0.11 8
SGO 70 54 TWO AV5 0.07 8
SGO 84 66 TWO AV3 0
8 SGO 80 60 TWO AV3
-0.02 8
SGO 78 68 TWO AV5 0
5.00 8
SGO 55 123 TWO AV3
-0.2 8
SGO 80 60 TWO AV4 0
9 SGO 78 68 TWO AV4
-0.04 8.00 9
SGO 86 72 TWO AV4
-0.02 9
SGO 76 60 TWO AV3
-0.09 10 SGO 92 58 TWO AV3
-0.07 10 SGO 88 72 TWO AV4
-0.02 10 SGO 106 60 TWO AV2 0.04 10 SGO 88 56 TWO AV5 0
11 SGO 98 66 TWO AV5 0.02 11 SGO 66 92 TWO AV3 0
6.00 12 SGO 88 72 TWO AV5 0
5.00 12 SGO 88 56 TWO AV2 0
13 SGO 78 68 TWO AV3
-0.09 11.00 13 SGO 94 70 TWO AV2
-0.04 13 SGO 66 92 TWO AV4
-0.02 8.00 13 SGO 76 60 TWO AV4
-0.05 14 SGO 88 72 TWO AV6
-0.07 14 to ULNRC-05933 Page 18 Prev SG Row Col Ind Su~~
Inch1
%TW
%TW SGO 99 71 TWO AV2
-0.02 15 SGO 92 58 TWO AV5
-0.07 17 SGO 80 58 TWO AV2 0
19 SGO 92 58 TWO AV4
-0.05 20 SGO 80 58 TWO AV5
-0.05 21 SGO 80 58 TWO AV4 0.02 22 SGO 76 60 TWO AV5
-0.09 22 SGO 88 56 TWO AV4
-0.05 5.00 26 SGO 80 58 TWO AV3 0.02 26 SGO 88 56 TWO AV3
-0.05 11.00 30