ML13002A448

From kanterella
Jump to navigation Jump to search

ALI Avb Wear 1R18_R1
ML13002A448
Person / Time
Site: Callaway 
(NPF-030)
Issue date: 12/20/2012
From: Ptasznik E
Union Electric Co, Ameren Corp
To: Lyon C
Plant Licensing Branch IV
Lyon C
Shared Package
ML13002A441 List:
References
TAC ME9087
Download: ML13002A448 (1)


Text

AVB WEAR Plugged Tu SG Row Col Ind Supp Inch1 Prev %TW

%TW SG SGC 49 39 TWD AV1 0

7 SGA SGC 49 39 TWD AV2 0

9 SGA SGB 52 76 TWD AV4

-0.15 6

SGA SGA 54 14 TWD AV1 0.02 9

SGA SGD 55 123 TWD AV3

-0.2 8

SGA SGA 58 32 TWD AV6 0.02 7

SGA SGC 58 44 TWD AV2

-0.07 8

SGA SGC 58 44 TWD AV3

-0.09 12 SGA SGC 58 44 TWD AV5

-0.04 13 SGA SGA 58 68 TWD AV2

-0.04 6

SGA SGA 58 68 TWD AV4

-0.13 10 SGB SGA 58 68 TWD AV3

-0.07 11 SGB SGA 58 68 TWD AV5 0

18 SGB SGC 59 103 TWD AV4

-0.13 7

SGB SGC 59 103 TWD AV5

-0.04 7

SGB SGA 60 64 TWD AV5

-0.02 13 SGB SGC 60 120 TWD AV3

-0.02 6

SGC SGB 61 67 TWD AV2

-0.02 8

SGC SGB 61 77 TWD AV3 0

10 SGC SGC 62 64 TWD AV2

-0.11 5

SGC SGC 62 64 TWD AV4

-0.07 6

SGC SGC 62 64 TWD AV5

-0.04 7

SGC SGD 63 19 TWD AV3

-0.15 6

SGC SGC 63 39 TWD AV4

-0.09 5

SGC SGC 64 62 TWD AV3

-0.07 11 SGC SGC 64 62 TWD AV4

-0.09 12 SGC SGC 64 80 TWD AV3 0

6 SGC SGC 64 80 TWD AV4

-0.29 9

SGC SGD 65 63 TWD AV4

-0.13 6

SGD SGB 65 67 TWD AV3

-0.07 5

SGB 65 67 TWD AV2

-0.09 6

SGB 65 67 TWD AV5 0.04 7

SGD 66 92 TWD AV3 0

6.00 12 SGD 66 92 TWD AV4

-0.02 8.00 13 SGC 67 65 TWD AV2 0.02 8

SGC 68 58 TWD AV5

-0.07 9

SGC 68 58 TWD AV4

-0.04 10 SGB 68 58 TWD AV3

-0.02 11 SGB 68 58 TWD AV4 0

15 SGC 69 35 TWD AV4

-0.04 8

SGA 69 43 TWD AV4

-0.04 12 SGA 69 43 TWD AV3

-0.02 17 SGA 69 51 TWD AV4 0.09 7

SGD 70 54 TWD AV4

-0.07 7

SGD 70 54 TWD AV5 0.07 8

SGA 71 79 TWD AV4 0.02 8

SGA 71 79 TWD AV3

-0.04 16 SGA 71 89 TWD AV3

-0.02 6

SGA 73 41 TWD AV3 0.04 12 SGC 73 63 TWD AV4

-0.02 11 SGC 73 63 TWD AV3

-0.02 12 SGC 73 63 TWD AV5

-0.04 17 SGC 73 67 TWD AV2

-0.02 5

SGC 73 67 TWD AV4

-0.07 8

SGC 73 67 TWD AV3

-0.04 14 SGA 73 69 TWD AV3

-0.07 7

SGC 73 79 TWD AV2

-0.02 10 SGC 73 79 TWD AV6

-0.18 14 SGC 73 79 TWD AV3

-0.11 24 SGC 73 79 TWD AV5

-0.09 27 SGC 73 79 TWD AV4

-0.11 29 SGA 74 96 TWD AV4 0

9 SGA 74 96 TWD AV3

-0.04 10 SGB 75 51 TWD AV3

-0.07 14 SGA 75 63 TWD AV3

-0.09 9

SGA 75 83 TWD AV2 0.02 6

SGA 75 83 TWD AV4

-0.04 13 SGA 75 83 TWD AV3

-0.04 13 SGA 75 83 TWD AV5

-0.07 14 SGD 76 60 TWD AV6 0

7 SGD 76 60 TWD AV3

-0.09 10 SGD 76 60 TWD AV4

-0.05 14 SGD 76 60 TWD AV5

-0.09 22 SGA 76 68 TWD AV1 0.04 6

SGB 76 68 TWD AV6

-0.04 13 SGB 76 68 TWD AV5

-0.02 13 SGA 76 68 TWD AV4

-0.02 14 SGA 76 68 TWD AV3 0.04 17 SGA 76 68 TWD AV5 0

21 SGB 76 68 TWD AV4

-0.07 22 SGB 76 68 TWD AV3

-0.11 23 SGB 76 68 TWD AV2 0

23 SGA 76 68 TWD AV2

-0.02 28 SGC 76 70 TWD AV2

-0.18 7

SGB 76 74 TWD AV3 0

6 SGB 76 74 TWD AV4

-0.11 9

SGA 77 51 TWD AV5

-0.11 10 SGA 77 51 TWD AV2

-0.02 12 SGA 77 51 TWD AV4 0.02 8.00 15 SGA 77 51 TWD AV3

-0.02 6.00 19 SGC 77 67 TWD AV4

-0.07 6

SGC 77 67 TWD AV2

-0.07 6

SGB 77 67 TWD AV3

-0.02 13 SGB 77 67 TWD AV6

-0.09 15 SGC 77 67 TWD AV3 0.02 16 SGB 77 67 TWD AV4 0.02 17 SGC 77 71 TWD AV5

-0.04 9

SGC 77 71 TWD AV4 0

11 SGC 77 71 TWD AV3

-0.04 9

27 SGD 77 73 TWD AV4 0.07 6

SGB 77 73 TWD AV2

-0.11 10 SGB 77 73 TWD AV4

-0.09 12 SGB 77 73 TWD AV3

-0.04 21 SGA 77 77 TWD AV3 0.02 8

SGA 77 77 TWD AV5

-0.02 11 SGA 77 77 TWD AV4

-0.04 14 SGC 77 81 TWD AV3 0.07 6

SGC 77 81 TWD AV2

-0.11 14 SGB 77 87 TWD AV2

-0.02 14 SGB 77 87 TWD AV3 0

16 SGB 77 87 TWD AV4 0

17 SGC 77 91 TWD AV5 0

6 SGC 77 91 TWD AV4 0.04 7

SGC 77 91 TWD AV3 0.04 10 SGC 78 66 TWD AV4 0.15 6

SGB 78 66 TWD AV5

-0.04 13 SGB 78 66 TWD AV6 0.05 13 SGC 78 66 TWD AV3

-0.04 14 SGC 78 66 TWD AV2 0

15 SGB 78 66 TWD AV3

-0.04 23 SGD 78 68 TWD AV6

-0.15 6.00 7

SGD 78 68 TWD AV5 0

5.00 8

SGD 78 68 TWD AV4

-0.04 8.00 9

SGD 78 68 TWD AV3

-0.09 11.00 13 SGA 78 76 TWD AV2 0.04 8.00 18 SGA 78 76 TWD AV5

-0.02 20 SGA 78 76 TWD AV4 0

26 SGA 78 76 TWD AV3

-0.04 12 29 SGA 78 88 TWD AV5

-0.02 6

SGA 78 88 TWD AV4

-0.02 12 SGA 79 47 TWD AV4

-0.04 8

SGA 79 47 TWD AV3

-0.04 14 SGA 79 49 TWD AV2

-0.04 8

SGC 79 51 TWD AV2

-0.07 7

SGC 79 51 TWD AV4

-0.02 12 SGC 79 51 TWD AV3

-0.04 19 SGD 80 58 TWD AV2 0

19 SGD 80 58 TWD AV5

-0.05 21

SGD 80 58 TWD AV4 0.02 22 SGD 80 58 TWD AV3 0.02 26 SGC 80 60 TWD AV5

-0.07 6

SGD 80 60 TWD AV3

-0.02 8

SGC 80 60 TWD AV2

-0.04 8

SGD 80 60 TWD AV4 0

9 SGC 80 60 TWD AV4

-0.04 18 SGC 80 60 TWD AV3 0

22 SGB 80 66 TWD AV3 0

9 SGC 80 70 TWD AV4 0.04 6

SGC 80 70 TWD AV3

-0.07 7

SGC 80 70 TWD AV5

-0.07 13 SGC 80 70 TWD AV2

-0.07 13 SGA 80 80 TWD AV4

-0.04 6

SGA 80 80 TWD AV3 0.02 7

SGC 81 51 TWD AV3 0.02 9.00 19 SGC 81 51 TWD AV5

-0.07 7.00 21 SGC 81 51 TWD AV4

-0.11 9.00 21 SGC 81 59 TWD AV4

-0.04 5

SGC 81 59 TWD AV3

-0.02 9

SGB 81 67 TWD AV5

-0.02 11 SGB 81 67 TWD AV4 0

19 SGB 81 67 TWD AV3

-0.07 22 SGC 81 77 TWD AV5 0

7.00 8

SGC 81 77 TWD AV4

-0.02 11 SGC 81 77 TWD AV3 0

7 23 SGC 81 77 TWD AV2 0

10 26 SGC 81 79 TWD AV6

-0.22 6

SGC 81 79 TWD AV5

-0.02 21 SGC 81 79 TWD AV4 0.04 26 SGC 81 79 TWD AV3 0.07 10 33 SGA 81 85 TWD AV4

-0.04 15 SGA 81 85 TWD AV2 0.04 18 SGA 81 85 TWD AV3

-0.04 22 SGC 82 40 TWD AV3

-0.04 7

SGC 82 62 TWD AV3

-0.02 7

SGB 82 66 TWD AV2

-0.07 13 SGB 82 66 TWD AV5

-0.04 17 SGB 82 66 TWD AV3

-0.04 30 SGB 82 74 TWD AV3 0.04 9

SGB 82 74 TWD AV4

-0.07 13 SGA 82 76 TWD AV4

-0.02 15 SGA 82 76 TWD AV3

-0.02 21 SGC 83 57 TWD AV3

-0.07 8

SGC 83 61 TWD AV3

-0.04 11 SGC 83 61 TWD AV2

-0.04 13 SGA 83 63 TWD AV5

-0.02 10

SGA 83 67 TWD AV4 0.04 8

SGC 83 67 TWD AV4 0

11 SGC 83 67 TWD AV2

-0.04 12 SGC 83 67 TWD AV3

-0.04 16 SGA 83 67 TWD AV2

-0.07 19 SGA 83 67 TWD AV3

-0.09 21 SGC 83 71 TWD AV2

-0.07 9

SGC 83 73 TWD AV5

-0.16 7

SGB 83 75 TWD AV5 0.07 6

SGC 83 75 TWD AV5

-0.02 7

SGB 83 75 TWD AV4 0

8 SGB 83 75 TWD AV2 0.04 9

SGB 83 75 TWD AV3

-0.02 13 SGB 84 56 TWD AV4 0.04 10 SGB 84 56 TWD AV3 0.04 11 SGC 84 64 TWD AV4

-0.07 8

SGC 84 64 TWD AV3

-0.02 13 SGD 84 66 TWD AV3 0

8 SGB 84 72 TWD AV3

-0.22 16 SGC 84 74 TWD AV3 0

8 SGC 84 76 TWD AV4

-0.02 7

SGC 84 76 TWD AV2

-0.09 8.00 18 SGC 84 76 TWD AV3

-0.02 11 26 SGA 84 78 TWD AV2

-0.09 6

SGA 84 82 TWD AV2

-0.02 8

SGA 84 82 TWD AV3

-0.07 11 SGC 84 88 TWD AV2

-0.11 6

SGC 84 88 TWD AV4

-0.02 7

SGC 84 88 TWD AV3 0.04 11 SGA 85 63 TWD AV6

-0.04 11 SGA 85 63 TWD AV2

-0.11 14 27 SGA 85 63 TWD AV3

-0.02 12 28 SGA 85 63 TWD AV4 0.02 17 34 SGA 85 63 TWD AV5

-0.04 12 34 SGA 85 65 TWD AV6 0.05 6

SGA 85 65 TWD AV5

-0.04 12 SGA 85 65 TWD AV3

-0.02 13 SGA 85 65 TWD AV2 0.04 15 SGC 85 69 TWD AV3

-0.02 7

SGA 85 71 TWD AV5

-0.02 7

SGA 85 71 TWD AV1

-0.02 7

SGA 85 71 TWD AV6

-0.09 10 SGA 85 71 TWD AV4

-0.09 17 SGA 85 71 TWD AV2

-0.09 27 SGA 85 71 TWD AV3

-0.09 28 SGA 85 75 TWD AV5

-0.09 6

SGA 85 75 TWD AV2

-0.09 8

SGB 85 77 TWD AV4 0

7 SGA 85 77 TWD AV5 0

10 SGB 85 77 TWD AV2 0

11 SGB 85 77 TWD AV3

-0.11 13 SGA 85 77 TWD AV2

-0.09 17 SGA 85 77 TWD AV3

-0.09 28 SGA 85 81 TWD AV2

-0.02 7

SGA 85 81 TWD AV3

-0.07 14 SGA 85 85 TWD AV3 0

12 SGB 86 64 TWD AV5

-0.04 11 SGB 86 64 TWD AV4

-0.09 16 SGB 86 64 TWD AV3

-0.04 21 SGB 86 68 TWD AV2

-0.04 6

SGB 86 68 TWD AV6

-0.07 14 SGB 86 68 TWD AV5 0

24 SGB 86 68 TWD AV4 0

24 SGB 86 68 TWD AV3

-0.02 27 SGD 86 72 TWD AV5 0

6 SGD 86 72 TWD AV3 0

7 SGD 86 72 TWD AV4

-0.02 9

SGA 86 84 TWD AV2

-0.02 6

SGA 86 84 TWD AV4

-0.07 7

SGA 86 84 TWD AV3

-0.04 14 SGC 87 71 TWD AV5 0

13 SGC 87 71 TWD AV3 0

14 SGA 87 79 TWD AV4 0

8 SGA 87 79 TWD AV3

-0.02 14 SGC 87 83 TWD AV3

-0.09 11 SGC 87 83 TWD AV4

-0.07 16 SGD 88 56 TWD AV5 0

11 SGD 88 56 TWD AV2 0

13 SGD 88 56 TWD AV4

-0.05 5

26 SGD 88 56 TWD AV3

-0.05 11 30 SGD 88 60 TWD AV4

-0.11 8

SGA 88 66 TWD AV3 0.02 9

SGA 88 68 TWD AV3 0

11 SGB 88 70 TWD AV6

-0.13 4.00 8

SGC 88 70 TWD AV5

-0.16 10 SGB 88 70 TWD AV1

-0.09 8.00 16 SGB 88 70 TWD AV2 0.07 9

23 SGB 88 70 TWD AV5 0.04 8

24 SGB 88 70 TWD AV4

-0.15 7

26 SGB 88 70 TWD AV3

-0.2 13 33 SGD 88 72 TWD AV4

-0.02 10 SGD 88 72 TWD AV5 0

5.00 12 SGD 88 72 TWD AV6

-0.07 14 SGB 88 78 TWD AV2 0

6

SGB 88 78 TWD AV6

-0.04 11 SGB 88 78 TWD AV5 0.04 17 SGB 88 78 TWD AV4 0.04 12 24 SGB 88 78 TWD AV3 0

10 26 SGB 88 88 TWD AV2 0

8 SGB 88 88 TWD AV3

-0.02 13 SGB 88 88 TWD AV4

-0.02 21 SGC 89 61 TWD AV1 0

6 SGC 89 61 TWD AV6

-0.02 9

22 SGC 89 61 TWD AV5

-0.04 12 32 SGC 89 61 TWD AV2

-0.04 15 34 SGC 89 61 TWD AV3

-0.02 15 35 SGC 89 61 TWD AV4 0

15 35 SGC 89 63 TWD AV4 0

8 SGC 89 63 TWD AV3

-0.04 9

SGB 89 63 TWD AV4

-0.09 9

SGB 89 63 TWD AV5 0.04 10 SGB 89 63 TWD AV2

-0.02 15 SGB 89 63 TWD AV3

-0.02 22 SGC 89 65 TWD AV3 0.04 11 SGC 89 67 TWD AV3

-0.09 9

SGC 89 67 TWD AV4 0.04 14 SGC 89 67 TWD AV5

-0.04 17 SGC 89 69 TWD AV4

-0.04 9

SGC 89 69 TWD AV2

-0.09 11 SGC 89 69 TWD AV3

-0.02 14 SGC 89 71 TWD AV2 0

20 SGC 89 71 TWD AV4

-0.02 7

23 SGC 89 71 TWD AV5

-0.04 9

25 SGC 89 71 TWD AV3

-0.09 11 33 SGC 89 75 TWD AV5 0

10 SGC 89 75 TWD AV4

-0.07 15 SGC 89 75 TWD AV3 0

21 SGC 90 56 TWD AV2 0

17 SGC 90 56 TWD AV3

-0.04 20 SGB 90 60 TWD AV4

-0.09 11 SGB 90 60 TWD AV2

-0.07 15 SGB 90 60 TWD AV3 0.04 19 SGB 90 68 TWD AV4

-0.07 6

SGB 90 68 TWD AV3

-0.02 9

SGC 90 72 TWD AV6

-0.04 5

SGC 90 72 TWD AV2

-0.07 9

SGC 90 72 TWD AV3

-0.02 10 SGC 90 72 TWD AV5

-0.02 6.00 12 SGC 90 76 TWD AV2

-0.04 8

SGC 91 51 TWD AV4 0

13 SGC 91 51 TWD AV2 0

17

SGC 91 51 TWD AV3 0

18 SGB 91 65 TWD AV5

-0.02 10 SGB 91 65 TWD AV1 0.02 10 SGB 91 65 TWD AV2

-0.04 7

27 SGB 91 65 TWD AV4

-0.07 9

29 SGB 91 65 TWD AV3

-0.04 16 37 SGC 91 67 TWD AV4

-0.02 14 SGC 91 69 TWD AV6 0.02 6

SGC 91 69 TWD AV2

-0.02 18 SGC 91 69 TWD AV4 0

19 SGC 91 69 TWD AV5

-0.04 28 SGC 91 69 TWD AV3

-0.04 31 SGC 91 71 TWD AV6 0

13 SGC 91 71 TWD AV5 0

8.00 15 SGC 91 73 TWD AV2 0

8 SGC 91 73 TWD AV3 0

16 SGC 91 75 TWD AV4

-0.07 10 SGC 91 75 TWD AV5

-0.07 12 SGC 91 75 TWD AV6

-0.02 14 SGD 92 58 TWD AV3

-0.07 10 SGD 92 58 TWD AV5

-0.07 17 SGD 92 58 TWD AV4

-0.05 20 SGA 92 64 TWD AV1 0

6 SGA 92 64 TWD AV5

-0.04 13 SGA 92 64 TWD AV3

-0.02 21 SGA 92 64 TWD AV4 0

22 SGA 92 64 TWD AV2

-0.07 22 SGA 92 72 TWD AV5

-0.04 7

SGA 92 72 TWD AV4

-0.02 15 SGA 92 72 TWD AV3

-0.04 24 SGA 92 78 TWD AV2

-0.04 6

SGA 92 78 TWD AV3

-0.04 7

SGA 92 82 TWD AV3

-0.02 12 SGA 92 82 TWD AV5

-0.02 21 SGA 92 82 TWD AV4 0

8 28 SGA 93 55 TWD AV4

-0.02 8

SGA 93 65 TWD AV2

-0.04 7

SGC 93 65 TWD AV1 0

6.00 8

SGA 93 65 TWD AV5

-0.07 9

SGA 93 65 TWD AV4 0

11 SGC 93 65 TWD AV3 0

11.00 15 SGA 93 65 TWD AV3 0

17 SGC 93 65 TWD AV2

-0.02 9.00 20 SGA 93 69 TWD AV3

-0.11 7

SGC 93 69 TWD AV2

-0.04 9

SGA 93 69 TWD AV6

-0.09 10 SGC 93 69 TWD AV4

-0.02 17

SGC 93 69 TWD AV5

-0.04 18 SGC 93 69 TWD AV3

-0.04 26 SGC 93 71 TWD AV2

-0.04 7

SGC 93 71 TWD AV6

-0.02 8

SGC 93 71 TWD AV5

-0.04 16 SGC 93 71 TWD AV4 0

6 23 SGC 93 71 TWD AV3

-0.07 8

28 SGA 93 73 TWD AV4 0.04 7

SGA 93 73 TWD AV3

-0.02 7

SGC 93 73 TWD AV5 0

8 SGC 93 75 TWD AV5 0

8 SGC 93 75 TWD AV3

-0.07 13 SGC 94 66 TWD AV2 0.09 7

SGC 94 66 TWD AV4

-0.02 7

SGC 94 66 TWD AV3

-0.04 8

SGD 94 70 TWD AV2

-0.04 13 SGC 94 72 TWD AV5 0.02 6

SGA 94 86 TWD AV3

-0.04 5

SGA 94 86 TWD AV5

-0.02 7

SGA 94 86 TWD AV6

-0.07 8

SGB 95 57 TWD AV5

-0.09 10 SGB 95 57 TWD AV3

-0.02 13 SGB 95 57 TWD AV4

-0.07 24 SGC 95 63 TWD AV3

-0.09 6

SGA 95 65 TWD AV5

-0.13 6

SGC 95 65 TWD AV2

-0.04 8

SGC 95 65 TWD AV3

-0.02 11 SGC 95 65 TWD AV5

-0.11 12 SGC 95 65 TWD AV4 0

12 SGB 95 69 TWD AV3

-0.11 9

SGB 95 69 TWD AV4

-0.02 9

SGC 95 73 TWD AV2

-0.04 7

SGA 95 73 TWD AV3

-0.04 9

SGA 95 73 TWD AV2

-0.04 13 SGC 95 73 TWD AV6 0

6.00 21 SGC 95 73 TWD AV4 0

6 25 SGC 95 73 TWD AV3 0

7 26 SGC 95 73 TWD AV5 0

7 27 SGB 95 79 TWD AV6

-0.07 10 SGB 95 79 TWD AV2 0

11 SGB 95 79 TWD AV5

-0.02 15 SGB 95 79 TWD AV3

-0.07 16 SGC 96 58 TWD AV2

-0.02 9.00 14 SGC 96 58 TWD AV4

-0.02 10 25 SGC 96 58 TWD AV3 0

15 32 SGC 96 64 TWD AV2

-0.02 9

SGC 96 64 TWD AV3

-0.02 16

SGC 96 64 TWD AV5

-0.11 18 SGC 96 64 TWD AV4

-0.02 23 SGD 96 66 TWD AV3

-0.07 7

SGA 96 66 TWD AV1 0.02 8

SGC 96 66 TWD AV2 0.07 15 SGA 96 66 TWD AV5

-0.04 15 SGC 96 66 TWD AV5

-0.04 20 SGA 96 66 TWD AV2

-0.04 23 SGC 96 66 TWD AV4

-0.02 24 SGA 96 66 TWD AV4

-0.02 5

27 SGC 96 66 TWD AV3 0

28 SGA 96 66 TWD AV3

-0.02 8

29 SGC 96 70 TWD AV5

-0.13 6

SGC 96 70 TWD AV1 0

10 SGA 96 70 TWD AV5

-0.02 12 SGC 96 70 TWD AV4 0

15 SGC 96 70 TWD AV2

-0.04 24 SGC 96 70 TWD AV3 0

26 SGC 96 74 TWD AV5 0

15 SGC 96 74 TWD AV3 0

19 SGC 96 74 TWD AV2 0

7.00 20 SGB 97 55 TWD AV2

-0.02 9

SGC 97 61 TWD AV2

-0.07 13 SGC 97 61 TWD AV5

-0.07 22 SGC 97 61 TWD AV4

-0.02 27 SGC 97 61 TWD AV3

-0.02 30 SGC 97 63 TWD AV5

-0.04 12 SGC 97 63 TWD AV4

-0.04 23 SGC 97 67 TWD AV4

-0.04 8

SGC 97 67 TWD AV3

-0.07 9

SGC 97 67 TWD AV2

-0.11 11 SGB 97 69 TWD AV4

-0.13 8

SGC 97 69 TWD AV6 0

9 SGB 97 69 TWD AV2

-0.11 13 SGC 97 69 TWD AV4 0

16 SGC 97 69 TWD AV5

-0.02 18 SGB 97 69 TWD AV3

-0.07 22 SGC 97 71 TWD AV2

-0.07 12 SGC 97 71 TWD AV5

-0.04 12 SGC 97 71 TWD AV4

-0.04 6

26 SGC 97 71 TWD AV3

-0.11 11 32 SGC 97 73 TWD AV6

-0.02 9

SGA 97 81 TWD AV1

-0.15 6

SGB 97 81 TWD AV3 0

7 SGB 97 81 TWD AV4

-0.02 11 SGC 97 83 TWD AV4

-0.31 8

SGD 98 66 TWD AV6 0

6

SGD 98 66 TWD AV2

-0.02 7

SGA 98 66 TWD AV1

-0.09 5.00 9

SGD 98 66 TWD AV5 0.02 11 SGA 98 66 TWD AV5

-0.04 17 SGA 98 66 TWD AV2

-0.04 8

28 SGA 98 66 TWD AV4

-0.07 7

28 SGA 98 66 TWD AV3

-0.07 12 33 SGC 98 68 TWD AV5

-0.02 6

SGA 98 68 TWD AV4

-0.09 7

SGC 98 68 TWD AV3

-0.02 13 SGA 98 68 TWD AV5 0

15 SGC 98 68 TWD AV2

-0.04 17 SGC 98 68 TWD AV4 0

25 SGB 98 70 TWD AV6

-0.02 15 SGB 98 70 TWD AV2

-0.02 16 SGB 98 70 TWD AV5 0

24 SGB 98 70 TWD AV4

-0.02 30 SGB 98 70 TWD AV3

-0.02 31 SGB 98 72 TWD AV5 0.04 11 SGA 98 76 TWD AV2

-0.09 6

SGA 98 84 TWD AV3

-0.09 11 SGA 98 84 TWD AV2

-0.04 14 SGA 99 65 TWD AV6 0.02 10 SGA 99 65 TWD AV5

-0.02 15 SGA 99 67 TWD AV6

-0.04 15 SGA 99 67 TWD AV1

-0.02 3.00 16 SGA 99 67 TWD AV5

-0.04 8

24 SGA 99 67 TWD AV4 0.04 3

28 SGA 99 67 TWD AV2

-0.11 6

32 SGA 99 67 TWD AV3

-0.04 8

35 SGD 99 71 TWD AV3 0

6 SGD 99 71 TWD AV2

-0.02 15 SGC 99 73 TWD AV3

-0.09 7

SGC 99 73 TWD AV4 0

8 SGC 99 73 TWD AV2

-0.09 11 SGC 99 73 TWD AV5 0

15 SGB 100 58 TWD AV5 0.04 7

SGC 100 72 TWD AV2

-0.09 5

SGC 100 72 TWD AV4 0

8 SGC 100 72 TWD AV3 0

12 SGC 100 74 TWD AV1 0.13 6

SGC 100 74 TWD AV4 0

7.00 17 SGC 100 74 TWD AV2 0

10.00 22 SGC 100 74 TWD AV3 0

9 26 SGC 101 63 TWD AV5

-0.02 9

SGC 101 63 TWD AV4

-0.02 13 SGC 101 69 TWD AV4

-0.02 6

SGC 101 69 TWD AV6 0.02 16 SGC 101 69 TWD AV5

-0.07 17 SGC 101 69 TWD AV3

-0.02 23 SGC 101 69 TWD AV2

-0.09 24 SGA 102 66 TWD AV6

-0.07 7

SGA 102 66 TWD AV5 0.11 10 SGC 102 74 TWD AV5 0.04 8

SGC 102 74 TWD AV6

-0.04 12 SGB 103 67 TWD AV4 0

10 SGC 103 67 TWD AV2

-0.04 7

22 SGC 103 67 TWD AV5 0

7 25 SGC 103 67 TWD AV3

-0.02 11 36 SGC 103 67 TWD AV4 0.02 20 39 SGA 104 64 TWD AV5

-0.15 10 SGA 104 64 TWD AV6

-0.02 3.00 11 SGC 104 72 TWD AV5 0.04 7

SGC 104 74 TWD AV4 0

12 SGC 104 82 TWD AV4 0

11 SGC 105 71 TWD AV3

-0.04 8

SGC 105 71 TWD AV4

-0.07 8

SGD 106 60 TWD AV2 0.04 10 SGA 106 72 TWD AV6

-0.13 8

SGC 106 76 TWD AV2

-0.02 7

SGA 107 65 TWD AV1

-0.15 9.00 14 SGA 107 65 TWD AV5

-0.02 4.00 14 SGA 107 65 TWD AV2

-0.04 11 23 SGA 107 65 TWD AV4

-0.09 6

23 SGA 107 65 TWD AV3

-0.09 14 30 SGC 107 69 TWD AV4

-0.02 7

SGC 107 69 TWD AV6 0

9 SGC 107 69 TWD AV5

-0.02 10 SGA 108 68 TWD AV2

-0.07 8

SGA 108 68 TWD AV4

-0.02 13 SGA 108 68 TWD AV3

-0.02 16 SGC 108 72 TWD AV6 0.05 8

SGC 108 72 TWD AV3 0.04 16 SGC 108 72 TWD AV5 0.07 21 SGC 108 72 TWD AV4 0.07 22 SGA 108 74 TWD AV2 0.02 7

SGA 108 74 TWD AV6

-0.04 7

SGA 108 74 TWD AV3

-0.13 8

SGA 108 74 TWD AV1

-0.02 10 SGA 108 74 TWD AV4 0

19 SGA 108 74 TWD AV5 0

21 SGA 109 61 TWD AV5

-0.02 11 SGA 109 61 TWD AV6

-0.18 8.00 18 SGA 109 67 TWD AV1

-0.02 9

SGA 109 67 TWD AV4

-0.07 9

SGA 109 67 TWD AV6

-0.02 15 SGA 109 67 TWD AV5 0.04 20 SGA 109 67 TWD AV3 0

22 SGA 109 67 TWD AV2

-0.13 24 SGA 109 69 TWD AV2

-0.04 7

SGA 109 69 TWD AV4

-0.09 7

SGA 110 68 TWD AV1

-0.04 8

SGA 110 68 TWD AV2

-0.13 6.00 20 SGA 110 68 TWD AV4 0.04 20 SGA 110 68 TWD AV3

-0.09 6

22 SGC 110 70 TWD AV4 0.04 7

SGC 110 70 TWD AV3 0.04 14 SGC 110 72 TWD AV5 0.11 8

SGC 110 72 TWD AV6 0

16 SGA 111 63 TWD AV2

-0.11 5.00 10 SGA 111 65 TWD AV6 0.07 9

SGC 111 67 TWD AV3

-0.07 6

SGC 111 67 TWD AV4

-0.07 8

SGB 111 71 TWD AV3 0

5 SGB 111 71 TWD AV2

-0.02 6

SGC 111 71 TWD AV5 0.04 8

SGC 111 71 TWD AV6 0.04 10 SGA 111 73 TWD AV4

-0.09 8

SGA 111 73 TWD AV5 0

14 SGA 111 73 TWD AV3

-0.11 19 SGA 111 73 TWD AV6 0.04 22 SGA 111 73 TWD AV2

-0.13 22

bes Row Col Outage Designation Code Type Material Heat #

Serial #

76 68 11-Oct 1R18 PLG ROLLED I690 0261 B73J-2 78 76 11-Oct 1R18 PLG ROLLED I690 0259 B73J-2 85 63 11-Oct 1R18 PLG ROLLED I690 0254 B73J-2 85 71 11-Oct 1R18 PLG ROLLED I690 0256 B73J-2 85 77 11-Oct 1R18 PLG ROLLED I690 0257 B73J-2 92 82 11-Oct 1R18 PLG ROLLED I690 0263 B73J-2 96 66 11-Oct 1R18 PLG ROLLED I690 0255 B73J-2 98 66 11-Oct 1R18 PLG ROLLED I690 0260 B73J-2 99 67 11-Oct 1R18 PLG ROLLED I690 0262 B73J-2 107 65 11-Oct 1R18 PLG ROLLED I690 0258 B73J-2 82 66 11-Oct 1R18 PLG ROLLED I690 0308 B73J-2 86 68 11-Oct 1R18 PLG ROLLED I690 0304 B73J-2 88 70 11-Oct 1R18 PLG ROLLED I690 0306 B73J-2 88 78 11-Oct 1R18 PLG ROLLED I690 0307 B73J-2 91 65 11-Oct 1R18 PLG ROLLED I690 0309 B73J-2 98 70 11-Oct 1R18 PLG ROLLED I690 0305 B73J-2 73 79 11-Oct 1R18 PLG ROLLED I690 0324 B73J-2 81 79 11-Oct 1R18 PLG ROLLED I690 0319 B73J-2 89 61 11-Oct 1R18 PLG ROLLED I690 0321 B73J-2 89 71 11-Oct 1R18 PLG ROLLED I690 0326 B73J-2 91 69 11-Oct 1R18 PLG ROLLED I690 0322 B73J-2 93 71 11-Oct 1R18 PLG ROLLED I690 0317 B73J-2 95 73 11-Oct 1R18 PLG ROLLED I690 0339 B73J-2 96 58 11-Oct 1R18 PLG ROLLED I690 0318 B73J-2 96 66 11-Oct 1R18 PLG ROLLED I690 0316 B73J-2 97 61 11-Oct 1R18 PLG ROLLED I690 0320 B73J-2 97 71 11-Oct 1R18 PLG ROLLED I690 0323 B73J-2 103 67 11-Oct 1R18 PLG ROLLED I690 0325 B73J-2 88 56 11-Oct 1R18 PLG ROLLED I690 0264 B73J-2

Install Date Notes 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/4/2011 11/4/2011 Max TW <28%

11/4/2011 11/4/2011 Max TW <28%

11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/5/2011 Max TW <28%

11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/2/2011

AVB WEAR Plugged Tu SG Row Col Ind Supp Inch1 Prev %TW

%TW SG SGA 54 14 TWD AV1 0.02 9

SGA SGA 58 68 TWD AV2

-0.04 6

SGA SGA 58 32 TWD AV6 0.02 7

SGA SGA 58 68 TWD AV4

-0.13 10 SGA SGA 58 68 TWD AV3

-0.07 11 SGA SGA 58 68 TWD AV5 0

18 SGA SGA 60 64 TWD AV5

-0.02 13 SGA SGA 69 51 TWD AV4 0.09 7

SGA SGA 69 43 TWD AV4

-0.04 12 SGA SGA 69 43 TWD AV3

-0.02 17 SGA SGA 71 89 TWD AV3

-0.02 6

SGA 71 79 TWD AV4 0.02 8

SGA 71 79 TWD AV3

-0.04 16 SGA 73 69 TWD AV3

-0.07 7

SGA 73 41 TWD AV3 0.04 12 SGA 74 96 TWD AV4 0

9 SGA 74 96 TWD AV3

-0.04 10 SGA 75 83 TWD AV2 0.02 6

SGA 75 63 TWD AV3

-0.09 9

SGA 75 83 TWD AV3

-0.04 13 SGA 75 83 TWD AV4

-0.04 13 SGA 75 83 TWD AV5

-0.07 14 SGA 76 68 TWD AV1 0.04 6

SGA 76 68 TWD AV4

-0.02 14 SGA 76 68 TWD AV3 0.04 17 SGA 76 68 TWD AV5 0

21 SGA 76 68 TWD AV2

-0.02 28 SGA 77 77 TWD AV3 0.02 8

SGA 77 51 TWD AV5

-0.11 10 SGA 77 77 TWD AV5

-0.02 11 SGA 77 51 TWD AV2

-0.02 12 SGA 77 77 TWD AV4

-0.04 14 SGA 77 51 TWD AV4 0.02 8.00 15 SGA 77 51 TWD AV3

-0.02 6.00 19 SGA 78 88 TWD AV5

-0.02 6

SGA 78 88 TWD AV4

-0.02 12 SGA 78 76 TWD AV2 0.04 8.00 18 SGA 78 76 TWD AV5

-0.02 20 SGA 78 76 TWD AV4 0

26 SGA 78 76 TWD AV3

-0.04 12.00 29 SGA 79 49 TWD AV2

-0.04 8

SGA 79 47 TWD AV4

-0.04 8

SGA 79 47 TWD AV3

-0.04 14 SGA 80 80 TWD AV4

-0.04 6

SGA 80 80 TWD AV3 0.02 7

SGA 81 85 TWD AV4

-0.04 15 SGA 81 85 TWD AV2 0.04 18 SGA 81 85 TWD AV3

-0.04 22 SGA 82 76 TWD AV4

-0.02 15 SGA 82 76 TWD AV3

-0.02 21 SGA 83 67 TWD AV4 0.04 8

SGA 83 63 TWD AV5

-0.02 10 SGA 83 67 TWD AV2

-0.07 19 SGA 83 67 TWD AV3

-0.09 21 SGA 84 78 TWD AV2

-0.09 6

SGA 84 82 TWD AV2

-0.02 8

SGA 84 82 TWD AV3

-0.07 11 SGA 85 75 TWD AV5

-0.09 6

SGA 85 65 TWD AV6 0.05 6

SGA 85 81 TWD AV2

-0.02 7

SGA 85 71 TWD AV5

-0.02 7

SGA 85 71 TWD AV1

-0.02 7

SGA 85 75 TWD AV2

-0.09 8

SGA 85 71 TWD AV6

-0.09 10 SGA 85 77 TWD AV5 0

10 SGA 85 63 TWD AV6

-0.04 11 SGA 85 85 TWD AV3 0

12 SGA 85 65 TWD AV5

-0.04 12 SGA 85 65 TWD AV3

-0.02 13 SGA 85 81 TWD AV3

-0.07 14 SGA 85 65 TWD AV2 0.04 15 SGA 85 77 TWD AV2

-0.09 17 SGA 85 71 TWD AV4

-0.09 17 SGA 85 63 TWD AV2

-0.11 14.00 27 SGA 85 71 TWD AV2

-0.09 27 SGA 85 77 TWD AV3

-0.09 28 SGA 85 71 TWD AV3

-0.09 28 SGA 85 63 TWD AV3

-0.02 12.00 28 SGA 85 63 TWD AV4 0.02 17.00 34 SGA 85 63 TWD AV5

-0.04 12.00 34 SGA 86 84 TWD AV2

-0.02 6

SGA 86 84 TWD AV4

-0.07 7

SGA 86 84 TWD AV3

-0.04 14 SGA 87 79 TWD AV4 0

8 SGA 87 79 TWD AV3

-0.02 14 SGA 88 66 TWD AV3 0.02 9

SGA 88 68 TWD AV3 0

11 SGA 92 64 TWD AV1 0

6 SGA 92 78 TWD AV2

-0.04 6

SGA 92 72 TWD AV5

-0.04 7

SGA 92 78 TWD AV3

-0.04 7

SGA 92 82 TWD AV3

-0.02 12 SGA 92 64 TWD AV5

-0.04 13 SGA 92 72 TWD AV4

-0.02 15 SGA 92 82 TWD AV5

-0.02 21 SGA 92 64 TWD AV3

-0.02 21 SGA 92 64 TWD AV4 0

22 SGA 92 64 TWD AV2

-0.07 22 SGA 92 72 TWD AV3

-0.04 24 SGA 92 82 TWD AV4 0

8.00 28 SGA 93 69 TWD AV3

-0.11 7

SGA 93 65 TWD AV2

-0.04 7

SGA 93 73 TWD AV4 0.04 7

SGA 93 73 TWD AV3

-0.02 7

SGA 93 55 TWD AV4

-0.02 8

SGA 93 65 TWD AV5

-0.07 9

SGA 93 69 TWD AV6

-0.09 10 SGA 93 65 TWD AV4 0

11 SGA 93 65 TWD AV3 0

17 SGA 94 86 TWD AV3

-0.04 5

SGA 94 86 TWD AV5

-0.02 7

SGA 94 86 TWD AV6

-0.07 8

SGA 95 65 TWD AV5

-0.13 6

SGA 95 73 TWD AV3

-0.04 9

SGA 95 73 TWD AV2

-0.04 13 SGA 96 66 TWD AV1 0.02 8

SGA 96 70 TWD AV5

-0.02 12 SGA 96 66 TWD AV5

-0.04 15 SGA 96 66 TWD AV2

-0.04 23 SGA 96 66 TWD AV4

-0.02 5.00 27 SGA 96 66 TWD AV3

-0.02 8.00 29 SGA 97 81 TWD AV1

-0.15 6

SGA 98 76 TWD AV2

-0.09 6

SGA 98 68 TWD AV4

-0.09 7

SGA 98 66 TWD AV1

-0.09 5.00 9

SGA 98 84 TWD AV3

-0.09 11 SGA 98 84 TWD AV2

-0.04 14 SGA 98 68 TWD AV5 0

15 SGA 98 66 TWD AV5

-0.04 17 SGA 98 66 TWD AV2

-0.04 8.00 28 SGA 98 66 TWD AV4

-0.07 7.00 28 SGA 98 66 TWD AV3

-0.07 12.00 33 SGA 99 65 TWD AV6 0.02 10 SGA 99 65 TWD AV5

-0.02 15 SGA 99 67 TWD AV6

-0.04 15 SGA 99 67 TWD AV1

-0.02 3.00 16 SGA 99 67 TWD AV5

-0.04 8.00 24 SGA 99 67 TWD AV4 0.04 3.00 28

SGA 99 67 TWD AV2

-0.11 6.00 32 SGA 99 67 TWD AV3

-0.04 8.00 35 SGA 102 66 TWD AV6

-0.07 7

SGA 102 66 TWD AV5 0.11 10 SGA 104 64 TWD AV5

-0.15 10 SGA 104 64 TWD AV6

-0.02 3.00 11 SGA 106 72 TWD AV6

-0.13 8

SGA 107 65 TWD AV5

-0.02 4.00 14 SGA 107 65 TWD AV1

-0.15 9.00 14 SGA 107 65 TWD AV4

-0.09 6.00 23 SGA 107 65 TWD AV2

-0.04 11.00 23 SGA 107 65 TWD AV3

-0.09 14.00 30 SGA 108 74 TWD AV6

-0.04 7

SGA 108 74 TWD AV2 0.02 7

SGA 108 74 TWD AV3

-0.13 8

SGA 108 68 TWD AV2

-0.07 8

SGA 108 74 TWD AV1

-0.02 10 SGA 108 68 TWD AV4

-0.02 13 SGA 108 68 TWD AV3

-0.02 16 SGA 108 74 TWD AV4 0

19 SGA 108 74 TWD AV5 0

21 SGA 109 69 TWD AV4

-0.09 7

SGA 109 69 TWD AV2

-0.04 7

SGA 109 67 TWD AV1

-0.02 9

SGA 109 67 TWD AV4

-0.07 9

SGA 109 61 TWD AV5

-0.02 11 SGA 109 67 TWD AV6

-0.02 15 SGA 109 61 TWD AV6

-0.18 8.00 18 SGA 109 67 TWD AV5 0.04 20 SGA 109 67 TWD AV3 0

22 SGA 109 67 TWD AV2

-0.13 24 SGA 110 68 TWD AV1

-0.04 8

SGA 110 68 TWD AV2

-0.13 6.00 20 SGA 110 68 TWD AV4 0.04 20 SGA 110 68 TWD AV3

-0.09 6.00 22 SGA 111 73 TWD AV4

-0.09 8

SGA 111 65 TWD AV6 0.07 9

SGA 111 63 TWD AV2

-0.11 5.00 10 SGA 111 73 TWD AV5 0

14 SGA 111 73 TWD AV3

-0.11 19 SGA 111 73 TWD AV2

-0.13 22 SGA 111 73 TWD AV6 0.04 22

bes Row Col Outage Designation Code Type Material Heat #

Serial #

76 68 11-Oct 1R18 PLG ROLLED I690 0261 B73J-2 78 76 11-Oct 1R18 PLG ROLLED I690 0259 B73J-2 85 63 11-Oct 1R18 PLG ROLLED I690 0254 B73J-2 85 71 11-Oct 1R18 PLG ROLLED I690 0256 B73J-2 85 77 11-Oct 1R18 PLG ROLLED I690 0257 B73J-2 92 82 11-Oct 1R18 PLG ROLLED I690 0263 B73J-2 96 66 11-Oct 1R18 PLG ROLLED I690 0255 B73J-2 98 66 11-Oct 1R18 PLG ROLLED I690 0260 B73J-2 99 67 11-Oct 1R18 PLG ROLLED I690 0262 B73J-2 107 65 11-Oct 1R18 PLG ROLLED I690 0258 B73J-2

Install Date Notes 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011 11/3/2011

AVB WEAR Plugged Tu SG Row Col Ind Supp Inch1 Prev %TW

%TW SG SGB 111 71 TWD AV3 0

5 SGB SGB 65 67 TWD AV3

-0.07 5

SGB SGB 83 75 TWD AV5 0.07 6

SGB SGB 52 76 TWD AV4

-0.15 6

SGB SGB 86 68 TWD AV2

-0.04 6

SGB SGB 65 67 TWD AV2

-0.09 6

SGB SGB 111 71 TWD AV2

-0.02 6

SGB 88 78 TWD AV2 0

6 SGB 90 68 TWD AV4

-0.07 6

SGB 76 74 TWD AV3 0

6 SGB 100 58 TWD AV5 0.04 7

SGB 85 77 TWD AV4 0

7 SGB 97 81 TWD AV3 0

7 SGB 65 67 TWD AV5 0.04 7

SGB 83 75 TWD AV4 0

8 SGB 88 88 TWD AV2 0

8 SGB 88 70 TWD AV6

-0.13 4.00 8

SGB 61 67 TWD AV2

-0.02 8

SGB 97 69 TWD AV4

-0.13 8

SGB 95 69 TWD AV4

-0.02 9

SGB 97 55 TWD AV2

-0.02 9

SGB 76 74 TWD AV4

-0.11 9

SGB 89 63 TWD AV4

-0.09 9

SGB 82 74 TWD AV3 0.04 9

SGB 83 75 TWD AV2 0.04 9

SGB 80 66 TWD AV3 0

9 SGB 95 69 TWD AV3

-0.11 9

SGB 90 68 TWD AV3

-0.02 9

SGB 77 73 TWD AV2

-0.11 10 SGB 95 79 TWD AV6

-0.07 10 SGB 61 77 TWD AV3 0

10 SGB 89 63 TWD AV5 0.04 10 SGB 95 57 TWD AV5

-0.09 10 SGB 103 67 TWD AV4 0

10 SGB 84 56 TWD AV4 0.04 10 SGB 91 65 TWD AV5

-0.02 10 SGB 91 65 TWD AV1 0.02 10 SGB 81 67 TWD AV5

-0.02 11 SGB 86 64 TWD AV5

-0.04 11 SGB 85 77 TWD AV2 0

11 SGB 95 79 TWD AV2 0

11 SGB 98 72 TWD AV5 0.04 11 SGB 68 58 TWD AV3

-0.02 11 SGB 97 81 TWD AV4

-0.02 11

SGB 84 56 TWD AV3 0.04 11 SGB 88 78 TWD AV6

-0.04 11 SGB 90 60 TWD AV4

-0.09 11 SGB 77 73 TWD AV4

-0.09 12 SGB 82 66 TWD AV2

-0.07 13 SGB 95 57 TWD AV3

-0.02 13 SGB 85 77 TWD AV3

-0.11 13 SGB 83 75 TWD AV3

-0.02 13 SGB 82 74 TWD AV4

-0.07 13 SGB 78 66 TWD AV5

-0.04 13 SGB 77 67 TWD AV3

-0.02 13 SGB 97 69 TWD AV2

-0.11 13 SGB 76 68 TWD AV5

-0.02 13 SGB 76 68 TWD AV6

-0.04 13 SGB 88 88 TWD AV3

-0.02 13 SGB 78 66 TWD AV6 0.05 13 SGB 86 68 TWD AV6

-0.07 14 SGB 77 87 TWD AV2

-0.02 14 SGB 75 51 TWD AV3

-0.07 14 SGB 89 63 TWD AV2

-0.02 15 SGB 68 58 TWD AV4 0

15 SGB 98 70 TWD AV6

-0.02 15 SGB 95 79 TWD AV5

-0.02 15 SGB 77 67 TWD AV6

-0.09 15 SGB 90 60 TWD AV2

-0.07 15 SGB 77 87 TWD AV3 0

16 SGB 88 70 TWD AV1

-0.09 8.00 16 SGB 95 79 TWD AV3

-0.07 16 SGB 86 64 TWD AV4

-0.09 16 SGB 84 72 TWD AV3

-0.22 16 SGB 98 70 TWD AV2

-0.02 16 SGB 82 66 TWD AV5

-0.04 17 SGB 77 67 TWD AV4 0.02 17 SGB 77 87 TWD AV4 0

17 SGB 88 78 TWD AV5 0.04 17 SGB 90 60 TWD AV3 0.04 19 SGB 81 67 TWD AV4 0

19 SGB 86 64 TWD AV3

-0.04 21 SGB 88 88 TWD AV4

-0.02 21 SGB 77 73 TWD AV3

-0.04 21 SGB 81 67 TWD AV3

-0.07 22 SGB 76 68 TWD AV4

-0.07 22 SGB 97 69 TWD AV3

-0.07 22 SGB 89 63 TWD AV3

-0.02 22 SGB 88 70 TWD AV2 0.07 9.00 23 SGB 76 68 TWD AV3

-0.11 23 SGB 76 68 TWD AV2 0

23

SGB 78 66 TWD AV3

-0.04 23 SGB 95 57 TWD AV4

-0.07 24 SGB 88 70 TWD AV5 0.04 8.00 24 SGB 86 68 TWD AV4 0

24 SGB 98 70 TWD AV5 0

24 SGB 88 78 TWD AV4 0.04 12.00 24 SGB 86 68 TWD AV5 0

24 SGB 88 70 TWD AV4

-0.15 7.00 26 SGB 88 78 TWD AV3 0

10.00 26 SGB 91 65 TWD AV2

-0.04 7.00 27 SGB 86 68 TWD AV3

-0.02 27 SGB 91 65 TWD AV4

-0.07 9.00 29 SGB 98 70 TWD AV4

-0.02 30 SGB 82 66 TWD AV3

-0.04 30 SGB 98 70 TWD AV3

-0.02 31 SGB 88 70 TWD AV3

-0.2 13.00 33 SGB 91 65 TWD AV3

-0.04 16.00 37

bes Row Col Outage Designation Code Type Material Heat #

Serial #

82 66 11-Oct 1R18 PLG ROLLED I690 0308 B73J-2 86 68 11-Oct 1R18 PLG ROLLED I690 0304 B73J-2 88 70 11-Oct 1R18 PLG ROLLED I690 0306 B73J-2 88 78 11-Oct 1R18 PLG ROLLED I690 0307 B73J-2 91 65 11-Oct 1R18 PLG ROLLED I690 0309 B73J-2 98 70 11-Oct 1R18 PLG ROLLED I690 0305 B73J-2

Install Date Notes 11/4/2011 11/4/2011 Max TW <28%

11/4/2011 11/4/2011 Max TW <28%

11/4/2011 11/4/2011

AVB WEAR SG Row Col Ind Supp Inch1 Prev %TW

%TW SGC 73 67 TWD AV2

-0.02 5

SGC 100 72 TWD AV2

-0.09 5

SGC 63 39 TWD AV4

-0.09 5

SGC 90 72 TWD AV6

-0.04 5

SGC 81 59 TWD AV4

-0.04 5

SGC 62 64 TWD AV2

-0.11 5

SGC 98 68 TWD AV5

-0.02 6

SGC 78 66 TWD AV4 0.15 6

SGC 62 64 TWD AV4

-0.07 6

SGC 95 63 TWD AV3

-0.09 6

SGC 60 120 TWD AV3

-0.02 6

SGC 96 70 TWD AV5

-0.13 6

SGC 77 91 TWD AV5 0

6 SGC 89 61 TWD AV1 0

6 SGC 77 67 TWD AV4

-0.07 6

SGC 64 80 TWD AV3 0

6 SGC 81 79 TWD AV6

-0.22 6

SGC 101 69 TWD AV4

-0.02 6

SGC 94 72 TWD AV5 0.02 6

SGC 80 60 TWD AV5

-0.07 6

SGC 80 70 TWD AV4 0.04 6

SGC 84 88 TWD AV2

-0.11 6

SGC 91 69 TWD AV6 0.02 6

SGC 111 67 TWD AV3

-0.07 6

SGC 100 74 TWD AV1 0.13 6

SGC 77 81 TWD AV3 0.07 6

SGC 77 67 TWD AV2

-0.07 6

SGC 104 72 TWD AV5 0.04 7

SGC 59 103 TWD AV4

-0.13 7

SGC 107 69 TWD AV4

-0.02 7

SGC 82 62 TWD AV3

-0.02 7

SGC 59 103 TWD AV5

-0.04 7

SGC 77 91 TWD AV4 0.04 7

SGC 49 39 TWD AV1 0

7 SGC 76 70 TWD AV2

-0.18 7

SGC 110 70 TWD AV4 0.04 7

SGC 83 75 TWD AV5

-0.02 7

SGC 94 66 TWD AV2 0.09 7

SGC 62 64 TWD AV5

-0.04 7

SGC 106 76 TWD AV2

-0.02 7

SGC 95 73 TWD AV2

-0.04 7

SGC 82 40 TWD AV3

-0.04 7

SGC 79 51 TWD AV2

-0.07 7

SGC 94 66 TWD AV4

-0.02 7

SGC 80 70 TWD AV3

-0.07 7

SGC 85 69 TWD AV3

-0.02 7

SGC 84 76 TWD AV4

-0.02 7

SGC 83 73 TWD AV5

-0.16 7

SGC 84 88 TWD AV4

-0.02 7

SGC 99 73 TWD AV3

-0.09 7

SGC 93 71 TWD AV2

-0.04 7

SGC 89 63 TWD AV4 0

8 SGC 108 72 TWD AV6 0.05 8

SGC 105 71 TWD AV4

-0.07 8

SGC 105 71 TWD AV3

-0.04 8

SGC 93 65 TWD AV1 0

6.00 8

SGC 93 71 TWD AV6

-0.02 8

SGC 80 60 TWD AV2

-0.04 8

SGC 81 77 TWD AV5 0

7.00 8

SGC 93 73 TWD AV5 0

8 SGC 102 74 TWD AV5 0.04 8

SGC 93 75 TWD AV5 0

8 SGC 97 67 TWD AV4

-0.04 8

SGC 73 67 TWD AV4

-0.07 8

SGC 69 35 TWD AV4

-0.04 8

SGC 91 73 TWD AV2 0

8 SGC 94 66 TWD AV3

-0.04 8

SGC 99 73 TWD AV4 0

8 SGC 84 74 TWD AV3 0

8 SGC 111 71 TWD AV5 0.04 8

SGC 58 44 TWD AV2

-0.07 8

SGC 97 83 TWD AV4

-0.31 8

SGC 67 65 TWD AV2 0.02 8

SGC 110 72 TWD AV5 0.11 8

SGC 84 64 TWD AV4

-0.07 8

SGC 90 76 TWD AV2

-0.04 8

SGC 100 72 TWD AV4 0

8 SGC 95 65 TWD AV2

-0.04 8

SGC 83 57 TWD AV3

-0.07 8

SGC 111 67 TWD AV4

-0.07 8

SGC 89 63 TWD AV3

-0.04 9

SGC 90 72 TWD AV2

-0.07 9

SGC 101 63 TWD AV5

-0.02 9

SGC 81 59 TWD AV3

-0.02 9

SGC 77 71 TWD AV5

-0.04 9

SGC 107 69 TWD AV6 0

9 SGC 49 39 TWD AV2 0

9 SGC 93 69 TWD AV2

-0.04 9

SGC 64 80 TWD AV4

-0.29 9

SGC 97 73 TWD AV6

-0.02 9

SGC 89 67 TWD AV3

-0.09 9

SGC 97 69 TWD AV6 0

9 SGC 83 71 TWD AV2

-0.07 9

SGC 96 64 TWD AV2

-0.02 9

SGC 89 69 TWD AV4

-0.04 9

SGC 97 67 TWD AV3

-0.07 9

SGC 68 58 TWD AV5

-0.07 9

SGC 88 70 TWD AV5

-0.16 10 SGC 90 72 TWD AV3

-0.02 10 SGC 73 79 TWD AV2

-0.02 10 SGC 68 58 TWD AV4

-0.04 10 SGC 111 71 TWD AV6 0.04 10 SGC 77 91 TWD AV3 0.04 10 SGC 89 75 TWD AV5 0

10 SGC 96 70 TWD AV1 0

10 SGC 107 69 TWD AV5

-0.02 10 SGC 91 75 TWD AV4

-0.07 10 SGC 89 65 TWD AV3 0.04 11 SGC 84 88 TWD AV3 0.04 11 SGC 73 63 TWD AV4

-0.02 11 SGC 81 77 TWD AV4

-0.02 11 SGC 83 61 TWD AV3

-0.04 11 SGC 104 82 TWD AV4 0

11 SGC 77 71 TWD AV4 0

11 SGC 97 67 TWD AV2

-0.11 11 SGC 89 69 TWD AV2

-0.09 11 SGC 83 67 TWD AV4 0

11 SGC 87 83 TWD AV3

-0.09 11 SGC 64 62 TWD AV3

-0.07 11 SGC 95 65 TWD AV3

-0.02 11 SGC 99 73 TWD AV2

-0.09 11 SGC 58 44 TWD AV3

-0.09 12 SGC 95 65 TWD AV4 0

12 SGC 97 63 TWD AV5

-0.04 12 SGC 64 62 TWD AV4

-0.09 12 SGC 97 71 TWD AV5

-0.04 12 SGC 97 71 TWD AV2

-0.07 12 SGC 90 72 TWD AV5

-0.02 6.00 12 SGC 100 72 TWD AV3 0

12 SGC 104 74 TWD AV4 0

12 SGC 79 51 TWD AV4

-0.02 12 SGC 95 65 TWD AV5

-0.11 12 SGC 91 75 TWD AV5

-0.07 12 SGC 83 67 TWD AV2

-0.04 12 SGC 102 74 TWD AV6

-0.04 12 SGC 73 63 TWD AV3

-0.02 12 SGC 83 61 TWD AV2

-0.04 13 SGC 80 70 TWD AV2

-0.07 13

SGC 91 51 TWD AV4 0

13 SGC 91 71 TWD AV6 0

13 SGC 84 64 TWD AV3

-0.02 13 SGC 58 44 TWD AV5

-0.04 13 SGC 98 68 TWD AV3

-0.02 13 SGC 93 75 TWD AV3

-0.07 13 SGC 97 61 TWD AV2

-0.07 13 SGC 101 63 TWD AV4

-0.02 13 SGC 87 71 TWD AV5 0

13 SGC 80 70 TWD AV5

-0.07 13 SGC 87 71 TWD AV3 0

14 SGC 91 75 TWD AV6

-0.02 14 SGC 78 66 TWD AV3

-0.04 14 SGC 110 70 TWD AV3 0.04 14 SGC 77 81 TWD AV2

-0.11 14 SGC 89 67 TWD AV4 0.04 14 SGC 89 69 TWD AV3

-0.02 14 SGC 96 58 TWD AV2

-0.02 9.00 14 SGC 91 67 TWD AV4

-0.02 14 SGC 73 67 TWD AV3

-0.04 14 SGC 73 79 TWD AV6

-0.18 14 SGC 96 70 TWD AV4 0

15 SGC 99 73 TWD AV5 0

15 SGC 96 74 TWD AV5 0

15 SGC 96 66 TWD AV2 0.07 15 SGC 93 65 TWD AV3 0

11.00 15 SGC 89 75 TWD AV4

-0.07 15 SGC 91 71 TWD AV5 0

8.00 15 SGC 78 66 TWD AV2 0

15 SGC 87 83 TWD AV4

-0.07 16 SGC 96 64 TWD AV3

-0.02 16 SGC 97 69 TWD AV4 0

16 SGC 83 67 TWD AV3

-0.04 16 SGC 91 73 TWD AV3 0

16 SGC 77 67 TWD AV3 0.02 16 SGC 93 71 TWD AV5

-0.04 16 SGC 110 72 TWD AV6 0

16 SGC 101 69 TWD AV6 0.02 16 SGC 108 72 TWD AV3 0.04 16 SGC 89 67 TWD AV5

-0.04 17 SGC 100 74 TWD AV4 0

7.00 17 SGC 91 51 TWD AV2 0

17 SGC 90 56 TWD AV2 0

17 SGC 101 69 TWD AV5

-0.07 17 SGC 98 68 TWD AV2

-0.04 17 SGC 93 69 TWD AV4

-0.02 17 SGC 73 63 TWD AV5

-0.04 17

SGC 91 51 TWD AV3 0

18 SGC 80 60 TWD AV4

-0.04 18 SGC 93 69 TWD AV5

-0.04 18 SGC 96 64 TWD AV5

-0.11 18 SGC 84 76 TWD AV2

-0.09 8.00 18 SGC 91 69 TWD AV2

-0.02 18 SGC 97 69 TWD AV5

-0.02 18 SGC 81 51 TWD AV3 0.02 9.00 19 SGC 96 74 TWD AV3 0

19 SGC 79 51 TWD AV3

-0.04 19 SGC 91 69 TWD AV4 0

19 SGC 96 66 TWD AV5

-0.04 20 SGC 90 56 TWD AV3

-0.04 20 SGC 96 74 TWD AV2 0

7.00 20 SGC 89 71 TWD AV2 0

20 SGC 93 65 TWD AV2

-0.02 9.00 20 SGC 81 51 TWD AV5

-0.07 7.00 21 SGC 89 75 TWD AV3 0

21 SGC 81 51 TWD AV4

-0.11 9.00 21 SGC 108 72 TWD AV5 0.07 21 SGC 95 73 TWD AV6 0

6.00 21 SGC 81 79 TWD AV5

-0.02 21 SGC 80 60 TWD AV3 0

22 SGC 103 67 TWD AV2

-0.04 7.00 22 SGC 89 61 TWD AV6

-0.02 9.00 22 SGC 100 74 TWD AV2 0

10.00 22 SGC 108 72 TWD AV4 0.07 22 SGC 97 61 TWD AV5

-0.07 22 SGC 96 64 TWD AV4

-0.02 23 SGC 81 77 TWD AV3 0

7.00 23 SGC 101 69 TWD AV3

-0.02 23 SGC 89 71 TWD AV4

-0.02 7.00 23 SGC 97 63 TWD AV4

-0.04 23 SGC 93 71 TWD AV4 0

6.00 23 SGC 101 69 TWD AV2

-0.09 24 SGC 96 70 TWD AV2

-0.04 24 SGC 73 79 TWD AV3

-0.11 24 SGC 96 66 TWD AV4

-0.02 24 SGC 103 67 TWD AV5 0

7.00 25 SGC 89 71 TWD AV5

-0.04 9.00 25 SGC 95 73 TWD AV4 0

6.00 25 SGC 98 68 TWD AV4 0

25 SGC 96 58 TWD AV4

-0.02 10.00 25 SGC 100 74 TWD AV3 0

9.00 26 SGC 81 77 TWD AV2 0

10.00 26 SGC 95 73 TWD AV3 0

7.00 26 SGC 84 76 TWD AV3

-0.02 11.00 26

SGC 81 79 TWD AV4 0.04 26 SGC 97 71 TWD AV4

-0.04 6.00 26 SGC 93 69 TWD AV3

-0.04 26 SGC 96 70 TWD AV3 0

26 SGC 95 73 TWD AV5 0

7.00 27 SGC 73 79 TWD AV5

-0.09 27 SGC 77 71 TWD AV3

-0.04 9.00 27 SGC 97 61 TWD AV4

-0.02 27 SGC 96 66 TWD AV3 0

28 SGC 93 71 TWD AV3

-0.07 8.00 28 SGC 91 69 TWD AV5

-0.04 28 SGC 73 79 TWD AV4

-0.11 29 SGC 97 61 TWD AV3

-0.02 30 SGC 91 69 TWD AV3

-0.04 31 SGC 97 71 TWD AV3

-0.11 11.00 32 SGC 96 58 TWD AV3 0

15.00 32 SGC 89 61 TWD AV5

-0.04 12.00 32 SGC 89 71 TWD AV3

-0.09 11.00 33 SGC 81 79 TWD AV3 0.07 10.00 33 SGC 89 61 TWD AV2

-0.04 15.00 34 SGC 89 61 TWD AV4 0

15.00 35 SGC 89 61 TWD AV3

-0.02 15.00 35 SGC 103 67 TWD AV3

-0.02 11.00 36 SGC 103 67 TWD AV4 0.02 20.00 39

Plugged Tubes SG Row Col Outage Designation Code Type Material Heat #

Serial #

SGC 73 79 11-Oct 1R18 PLG ROLLED I690 0324 B73J-2 SGC 81 79 11-Oct 1R18 PLG ROLLED I690 0319 B73J-2 SGC 89 61 11-Oct 1R18 PLG ROLLED I690 0321 B73J-2 SGC 89 71 11-Oct 1R18 PLG ROLLED I690 0326 B73J-2 SGC 91 69 11-Oct 1R18 PLG ROLLED I690 0322 B73J-2 SGC 93 71 11-Oct 1R18 PLG ROLLED I690 0317 B73J-2 SGC 95 73 11-Oct 1R18 PLG ROLLED I690 0339 B73J-2 SGC 96 58 11-Oct 1R18 PLG ROLLED I690 0318 B73J-2 SGC 96 66 11-Oct 1R18 PLG ROLLED I690 0316 B73J-2 SGC 97 61 11-Oct 1R18 PLG ROLLED I690 0320 B73J-2 SGC 97 71 11-Oct 1R18 PLG ROLLED I690 0323 B73J-2 SGC 103 67 11-Oct 1R18 PLG ROLLED I690 0325 B73J-2

Install Date Notes 11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/5/2011 Max TW <28%

11/4/2011 11/4/2011 11/4/2011 11/4/2011 11/4/2011

AVB WEAR SG Row Col Ind Supp Inch1 Prev %TW

%TW SGD 63 19 TWD AV3

-0.15 6

SGD 65 63 TWD AV4

-0.13 6

SGD 86 72 TWD AV5 0

6 SGD 98 66 TWD AV6 0

6 SGD 77 73 TWD AV4 0.07 6

SGD 99 71 TWD AV3 0

6 SGD 98 66 TWD AV2

-0.02 7

SGD 78 68 TWD AV6

-0.15 6.00 7

SGD 86 72 TWD AV3 0

7 SGD 76 60 TWD AV6 0

7 SGD 70 54 TWD AV4

-0.07 7

SGD 96 66 TWD AV3

-0.07 7

SGD 88 60 TWD AV4

-0.11 8

SGD 70 54 TWD AV5 0.07 8

SGD 84 66 TWD AV3 0

8 SGD 80 60 TWD AV3

-0.02 8

SGD 78 68 TWD AV5 0

5.00 8

SGD 55 123 TWD AV3

-0.2 8

SGD 80 60 TWD AV4 0

9 SGD 78 68 TWD AV4

-0.04 8.00 9

SGD 86 72 TWD AV4

-0.02 9

SGD 76 60 TWD AV3

-0.09 10 SGD 92 58 TWD AV3

-0.07 10 SGD 88 72 TWD AV4

-0.02 10 SGD 106 60 TWD AV2 0.04 10 SGD 88 56 TWD AV5 0

11 SGD 98 66 TWD AV5 0.02 11 SGD 66 92 TWD AV3 0

6.00 12 SGD 88 72 TWD AV5 0

5.00 12 SGD 88 56 TWD AV2 0

13 SGD 78 68 TWD AV3

-0.09 11.00 13 SGD 94 70 TWD AV2

-0.04 13 SGD 66 92 TWD AV4

-0.02 8.00 13 SGD 76 60 TWD AV4

-0.05 14 SGD 88 72 TWD AV6

-0.07 14 SGD 99 71 TWD AV2

-0.02 15 SGD 92 58 TWD AV5

-0.07 17 SGD 80 58 TWD AV2 0

19 SGD 92 58 TWD AV4

-0.05 20 SGD 80 58 TWD AV5

-0.05 21 SGD 80 58 TWD AV4 0.02 22 SGD 76 60 TWD AV5

-0.09 22 SGD 88 56 TWD AV4

-0.05 5.00 26 SGD 80 58 TWD AV3 0.02 26

SGD 88 56 TWD AV3

-0.05 11.00 30

Plugged Tubes SG Row Col Outage Designation Code Type Material Heat #

Serial #

SGD 88 56 11-Oct 1R18 PLG ROLLED I690 0264 B73J-2

Install Date Notes 11/2/2011