Entergy Pre-Filed Evidentiary Hearing Exhibit ENT00575E, Quarter 2011 Rolling Average Cesium, Cobalt, and Nickel Activity Map
ML12276A492
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 09/14/2012
From:
GZA GeoEnvironmental, Entergy Nuclear Operations
To:
Atomic Safety and Licensing Board Panel
SECY RAS
References
RAS 23568, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12276A492 (157)


Text

    1. ## # ## ## #

G

^

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

? @

?

?

? @

?

?

?

?

?

?

?

?

?

?

?

?

?

?

Storage storage Gravel Gravel Storage No Access Grass Earth Parking Asphalt Asphalt curb Asphalt parking Asphalt Concrete curbs Concrete curb Concrete Concrete curb Wooden curb Grass A/C UNIT Handicap ramp A/C unit on concrete Stone curbs Asphalt drive Asphalt parking Asphalt parking Asphalt parking Asphalt parking Asphalt curb Shrubs Trans.

Transformer area and switch gear Storage Containers A/C Units Grass Concrete curb Grass Shrubs Open gr ate Tank Asphalt drive Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt drive Asphalt Asphalt Drive Gravel Gravel Transformer yard Asphalt Drive this Area No Access Asphalt Conc rete Retaining Wa ll Stone retaining wall Gravel parking Gravel parking Gravel parking Gravel parking Stone curbs Stone curbs Asphalt parking Concrete curb Asphalt parking Concrete curb curb pad Asphalt curb Asphalt curb Asphalt parking Grass Asphalt curb Asphalt curb Grass Asphalt curb Asphalt parking Gravel parking Storage Storage Tank Fuel Oil Grass Asphalt drive Storage units Gravel Parking lot Asphalt Tank Overhead walkway Concrete curb Asphalt parking Asphalt parking Asphalt Asphalt Asphalt Asphalt Concrete pier Courtyard Asphalt Rip-rap 110 140 120 130 30 30 40 50 30 40 50 90 70 70 80 90 80 80 90 100 110 110 110 110 120 120 100 70 60 70 80 90 60 80 90 100 100 0

110 140 140 Transformer Gravel Storage Tank Fuel Oil Tank Tank Tank Covered Concrete Asphalt parking Condensate Tank Transformers on raised Concrete Pad Trans.

Transformers Concrete slab Tank Grass Transformers on raised Concrete Pad Tank Concrete Bridge Concrete Bridge Storage Tank Transformer Substation "H" Trailer Trans Tank Storage Tank Tank Pit Asphalt Trans Trans Trans Storage Tanks Asphalt Grass Vent pit Mach.

stand Unit 2 Condensate Storage Tank Liquid Nitrogen Transformers Yard (Gravel)

DISCHARGE OUTFALL CANAL Tank Gravel Shrubs Shrubs Shrubs Overhead Crane Grass FUEL TRAN SFE R PO O L STO RA GE PO O L STO RA GE PO O L FA IL ED FU EL AUX. PO O L DIS ASS EM B LY PO O L CAS K L O AD PO O L CAS K W AS H &

DIS ASS EM B LY ISO L ATIO N PI T PU MP SU CTI ON WELL WATER STO RA GE PO O L ROOF DRAIN ELEVATION 65' 43.8' 43.8' 43.8' 21.75' 22.75' (EL.=0.0) 33' 13' 43.8' 33' 33' 33' 33' 33' 42.5' 42.5' MH-4 MH-4A MH-5 MH-6 MH-2 B6 B6A B5 B4 B4A B3 B3A B2A B2 B1 A2 A1 U3-MH-14 F5 A2A CB-B CB-E CB-F C-1 C-3 D2 B7 B8 CB-33 CB-34 CB-15 CB-14 CB-13 CB-32 CB-31 CB-30 A7 U1-CB-22 U3-CB (U1-CB-10)

CB-29 U3-CB (U1-CB-9)

U1-CB-21 U1-CB-20 CB-28 CB-24 CB-27 E16 E16 E16A CB-6 CB-5A (CB-6)

CB-5B CB-7 CB-5 MH16 CB-3B CB3A CB4 CB-2C CB3 CB-2B CB-2A CB-2 CB-1 MH18 MH8 MH17 MH7 MH23A CB-16 MH9 MH10 MH11 MH22 MH21 MH13 MH3 MH12 MH1 CB-18 MH15 CB-19 CB-23 MH14 C2 E7 E6 E8 E9 E10 E11 E5 E5A E4 E4 E4A E3B E3 E3A F3 F4 CB E2 E2A F6 F7 E2B E2C E1 A6 A5 A3A A3 A4 E14 E15 E15A (U1-CB-8)

AB E13 E12 D1 CB-17 F2 F1 CB-12 MH-23 MH-19 MH-20 ROOF DRAIN Turbine Generator Building 2 Turbine Generator Building 1 Turbine Generator Building 3 Transformer Yard PAB Water Storage Tank FUEL POOL UNIT 2 1,015' 640' WEST FUEL POOL UNIT 1 UNIT 3 Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co UTILITY TUNNEL UTILITY TUNNEL CSS CSS TRENCH Cs Ni Co Cs Ni Co Cs Ni Co 50 40 30 20 10 5

50 40 30 20 5

20 13 10 Cs Ni Co B-1 Cs Ni Co B-6 ALL EYW AY U1-SFDS Cs Ni Co U1-NCD Cs Ni Co Cs Ni Co MH-5 VCFD 2

2 2

2 2

4 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

5 I-2 HR-1 U3-3 U3-2 U3-1 RW-1 OUT-1 U3-C1 U2-C1 MW-67 MW-66 MW-37 MW-36 MW-35 MW-34 MW-33 U3-4S U3-4D MW-52 MW-51 MW-50 MW-49 MW-47 MW-46 MW-45 MW-44 MW-42 MW-41 MW-38 MW-32 MW-31 MW-40 MW-48 MW-43 MW-39 U3-T2 U3-T1 MW-65 MW-62 MW-60 MW-59 MW-58 MW-57 MW-56 MW-55 MW-54 MW-53 MW-30 MW-64 MW-61 MW-63 U1-CSS MW-105 MW-101 MW-110 MW-111 MW-112 MW-109 MW-108 MW-107 H U D S O N R I V E R ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 6.79 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 34 0.1 8.3 7.2 7.05 9.77

-1.3 4.68 5.16 6.14 6.02 8.44 3.69 3.76 9.02 0.81 8.94 2.69 3.81 7.88 1.22 33.9 22.7 21.9 10.6 3.13 3.29 6.97 4.06 5.76 6.41 7.45 9.05 8.82 9.02 9.92 2.34 7.06 6.46 7.19 5.55 6.04 5.64 0.49 0.68 0.47 2.52 0.47 0.16 2.04 45.79 39.64 11.53 12.16 44.48 12.81 35.07 34.43 41.21 44.13 50.75

-1.64

-0.15

-0.48 29.36 37.68 36.03 40.36 49.24 40.66 43.87 44.32 46.83 52.35 54.22 32.72 23.79 24.43 24.79 25.12 25.21 26.96 30.71 31.76 32.15 25.45 26.68 21.08 22.37 25.16 29.05 10.48 10.54 10.68 12.36 11.71 10.27

-1.19

-1.54

-0.86

-2.26

-0.98

-1.24

-0.13

-0.08

-1.79

-1.69

-1.85

-0.37

-0.85

-1.24

-0.84

-0.15

-0.12

-1.93

-0.14

-0.86

-0.82

-0.02

-1.56

-1.02

-2.59

-2.25

-0.91

-2.03 115.76 DRY ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 260.5 ND ND ND ND ND ND 11700 18.22 24825 14.445 ND ND ND ND ND ND ND 9.45 0.29 21.51 ND 234.75 Plant North N

N 50 0

50 100 150 25 Feet Figure No.:

Job No.:

Dwg. Date:

Proj. Mgr.: MJB Designed By: MJB Reviewed By: MJB Operator: GAS 01.0017869.92 8-Q1 INDIAN POINT ENERGY CENTER BUCHANAN, NEW YORK GZA GeoEnvironmental, Inc.

One Edgewater Drive Norwood, MA 02062 Phone: (781) 278-3700 Fax: (781) 278-5701 1st QUARTER 2011 ROLLING AVERAGE CESIUM, COBALT, AND NICKEL ACTIVITY MAP 1

1st QUARTER 2011 ROLLING AVERAGE CESIUM, COBALT, AND NICKEL ACTIVITY MAP 1

East Fuel Pool LEGEND Cesium Data1 Average Cs, pCi/L Cobalt Data1 Average Co, pCi/L Nickel Data 1 Average Ni, pCi/L Not Detected (ND)

ND - 10 10 - 50 50 - 500 500 - 1,000 1,000 - 5,000

> 5,000 No Depth-Specific Samples ND 4.2 37 294 836 4460 6000 Not Detected (ND)

ND - 25 25 - 100 100 - 200 200 - 300 300 - 500

> 500 No Depth-Specific Samples ND 4

83 194 250 350 508 Not Detected (ND)

ND - 12 12 - 25 25 - 50 50 - 100 100 - 250 250 - 500

> 500 No Depth-Specific Samples ND 4

20 49 54 207 300 526 Groundwater Elevation Contours Depth-Specific Data Probable Legacy Release SSCs MW-30 Boring / Monitoring Installation Designation Longterm Radionuclide Monitoring Installation

?

Standby Radionuclide Monitoring Installation

?

Unit 1 West Fuel Pool (All U1-SFPs drained and inactive as of October 2008)

Unit 2 Fuel Pool (All identified leaks repaired as of December 2007)

Containment Spray Sump Trench Terminated Connection To Storm Drain Drain Exfiltration Inter-Structure Joint / Mud Mat Contours Other Than 10' Interval 20 5

11.3 11.9 12.6 12.8 Screened in Soil Screened in Bedrock Multiple Screened Intervals w/ Depth 6000 836 294 Average activity of Cs 137 (pCi/L) for each screened interval.

37 508 250 194 4

526 207 49 20 Average activity of Co 60 (pCi/L) for each screened interval.

Average activity of Ni 63 (pCi/L) for each screened interval.

3 Transient Distillate Tank Valve Leak in Unit 1 Fuel Storage Building - 3/07/2009 G

4 Footing Drain Active Storm Drain Catch Basin Abandoned Storm Drain Ambient "Watertable" Contours for Q4 2008 (11/11/2008) 1 1

Groundwater elevation for each screened interval at time of low river tide for Q4 2008 (11/11/2008).

1 1

^

Transient Spill from Temporary R.O. Skid Piping -

Entered MW-32 Vault and MH 11/21/2009 5

Notes:

1. Groundwater contours drawn from Q4 2008 groundwater data to show groundwater conditions used for recalibration of the Precipitation Mass Balance Model (see Q2 2009 LTM Report). These contours developed from limited data recorded on 11/11/2008. Actual elevations may vary from conditions shown and the actual distribution of piezometric heads is likely more complex than indicated.

Data Notes:

1. Average Cesium, Cobalt, and Nickel activity values are yearly rolling arithmetic averages of the current and preceeding three quarters' data.

Only values greater than the MDC are used in this average, thus adding a degree of conservatism to the subsequent dose computations.

2. Storm or foundation drain sampling locations, for which investigation levels are not applicable.
3. Historically elevated Tritium levels in MW-42-49 obsrved during Q1 2009 were consistent with leakage visually identified on 03/07/2009 (and terminated immediately thereafter) from the waste distillate tank valves located within the Unit 1 fuel storage building. Elevated tritium levels not seen in MW-53; therefore, this transient leakage was likely to have been generally confined to, and contained by, the Unit 1 North Curtain Drain.
4. Historically elevated Tritium levels in MW-45-42 observed during Q2 2009 were consistent with an increased activity observed in Unit 3 Manhole A2. This release was initially detected in a storm drain sample collected 03/25/2009 under the 80-10 Effluents Program. This Tritium peak dissipated prior to samples taken during the subsequent quarter. Additionally, transient Tritium peaks have been recently detected in MH-A2 from Q3 2010 to Q1 2011. These increases are consistent with elevated Tritium levels in MW-41-40, MW-46 and B-1. Based on investigations initiated in, and ongoing since, 2009 and the more recent sampling of the Unit 3 Fuel Storage Building (FSB) roof drains, it has been concluded that these increases in storm drain and monitoring well Tritium activity are due to condensation of SFP evaporation on the FSB roof (Washout) when the exhaust fan is not operating, which then enters the roof drains and discharges directly into MH-A2 during rainfall events.
5. Elevated levels of Tritium detected in MH-9 and MH-10a during routine 80-10 Effluents Program sampling on 1/15/2010 appears to have originated from a November 21, 2009 transient leak in temporary RWST / R.O. skid connection hoses, which flowed into MH-9. It also appears that this release entered the well vault for MW-32, and may have penetrated the well casings and entered the subsurface around the monitoring installation.

General Notes:

1. Base map was developed from an untitled electronic file provided by Badey and Watson Surveying and Engineering, P.C., Dated 2/3/06; CAD file name : "GZA.dwg".

© 2012 - GZA GeoEnvironmental, Inc. \\\\gzanor\\Jobs\\17,000-18,999\\17869\\17869-91.MG\\Figures\\GIS\\MXD Documents\\2011-comb\\12-09-14 F08 Q1 2011 Rolling Average Cesium, Cobalt, and Nickel Activity Map 17869-92_final.mxd, 9/14/2012, 4:50:45 PM, jennifer.pisani 09-14-2012 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4

Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2

Quarter 3 Post Quarter 3

Quarter 4 Post Quarter 4

Quarter 1 Post Quarter 1 2010 2010 2010 2010 2010 2010 2011 2011 2010 2010 2010 2010 2010 2010 2011 2011 MW-30-69 ND ND ND ND/ND ND NA ND ND positive ND MW-53-82 ND NA ND NA ND NA ND NA positive ND MW-30-84 ND ND ND ND/ND ND NA ND ND positive ND MW-53-120 ND NA ND NA ND NA ND NA positive ND MW-31-49 ND ND ND ND/ND ND NA ND ND positive ND MW-54-37 ND NA ND NA ND NA ND NA positive ND MW-31-63 ND ND ND ND/ND ND NA ND ND positive ND MW-54-58 ND NA ND NA ND NA ND NA positive ND MW-31-85 ND ND ND ND/ND ND NA ND ND positive ND MW-54-123 ND NA ND NA ND NA ND NA positive ND MW-32-48 ND NA ND ND NA NA NA NA positive ND MW-54-144 ND NA ND NA ND NA ND NA positive ND MW-32-59 ND ND ND ND/ND ND NA ND ND positive ND MW-54-173 ND NA ND NA ND NA ND NA positive ND MW-32-85 ND ND ND ND/ND ND NA ND ND positive ND MW-54-190 NA NA NA NA ND NA ND NA positive ND MW-32-149 ND ND ND ND/ND ND NA ND ND positive ND MW-55-24 ND NA ND NA ND NA ND NA positive ND MW-32-173 ND ND ND ND/ND ND NA ND ND positive ND MW-55-35 ND NA ND NA ND NA ND NA positive ND MW-32-190 ND ND ND ND/ND ND NA ND ND positive ND MW-55-54 ND NA ND NA ND NA ND NA positive ND MW-33 ND NA ND ND NA NA NA NA positive ND MW-56-53 ND NA ND NA ND NA NA NA positive ND MW-35 NA ND NA NA NA NA NA NA positive ND MW-56-83 NA NA NA NA ND NA NA NA positive ND MW-36-24 ND NA ND NA ND NA ND NA positive ND MW-57-11 ND NA ND NA NA NA NA NA positive ND MW-36-41 ND NA ND NA ND NA ND NA positive ND MW-57-20 ND NA ND NA NA NA NA NA positive ND MW-36-52 ND NA ND NA ND NA ND NA positive ND MW-57-45 ND NA ND NA NA NA NA NA positive ND MW-37-22 ND NA ND NA ND NA ND NA positive ND MW-58-26 ND NA ND NA ND NA NA NA positive ND MW-37-32 ND NA ND NA ND NA ND NA positive ND MW-58-65 ND NA ND NA ND NA NA NA positive ND MW-37-40 ND NA ND NA ND NA ND NA positive ND MW-60-35 ND ND ND NA ND NA ND NA positive ND MW-37-57 ND NA ND NA ND NA ND NA positive ND MW-60-53 ND ND ND NA ND NA ND NA positive ND MW-39-67 ND NA ND NA ND NA NA NA positive ND MW-60-72 NA ND ND NA ND NA ND NA positive ND MW-39-84 ND NA ND NA ND NA NA NA positive ND MW-60-135 ND ND ND NA ND NA ND NA positive ND MW-39-102 ND NA ND NA ND NA NA NA positive ND MW-60-154 ND ND ND NA ND NA ND NA positive ND MW-39-124 ND NA ND NA ND NA NA NA positive ND MW-60-176 ND ND ND NA ND NA ND NA positive ND MW-39-183 ND NA ND NA ND NA NA NA positive ND MW-62-18 ND NA ND NA ND NA ND NA positive ND MW-39-195 ND NA ND NA ND NA NA NA positive ND MW-62-37 ND NA ND NA ND NA ND NA positive ND MW-40-27 ND NA ND NA ND NA ND NA positive ND MW-62-53 ND NA ND NA ND NA ND NA positive ND MW-40-46 ND NA ND NA ND NA ND NA positive ND MW-62-71 ND NA ND NA ND NA ND NA positive ND MW-40-81 ND NA ND NA ND NA ND NA positive ND MW-62-92 ND NA ND NA ND NA ND NA positive ND MW-40-100 ND NA ND NA ND NA 2.46E+01**

NA positive ND MW-62-138 ND NA ND NA ND NA ND NA positive ND MW-40-127 ND NA ND NA ND NA 5.07E+01**

NA positive ND MW-62-182 ND NA ND NA ND NA ND NA positive ND MW-40-162 ND NA ND NA ND NA ND NA positive ND MW-63-18 ND NA ND NA ND NA ND NA positive ND MW-41-40 ND NA ND NA ND NA ND NA positive ND MW-63-34 ND NA ND NA ND NA ND NA positive ND MW-41-63 ND NA ND NA ND NA ND NA positive ND MW-63-50 ND NA ND NA ND NA ND NA positive ND MW-42-49 2.37E+04 NA 1.87E+04 NA 2.39E+04 NA 3.30E+04 NA 6.58E+04 2.48E+04 MW-63-93 ND NA ND NA ND NA ND NA positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-112 ND NA ND NA ND NA ND NA positive ND MW-43-28 ND NA ND NA ND NA ND NA positive ND MW-63-121 ND NA ND NA ND NA ND NA positive ND MW-43-62 ND NA ND NA ND NA ND NA positive ND MW-63-163 ND NA ND NA ND NA ND NA positive ND MW-44-66 NA ND NA NA ND NA ND NA positive ND MW-63-174 ND NA ND NA ND NA ND NA positive ND MW-44-102 ND ND ND NA ND NA ND NA positive ND MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-45-42 ND NA ND NA ND NA ND NA positive ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-45-61 ND NA ND NA ND NA ND NA positive ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-46 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND NA ND NA ND NA positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND NA ND NA ND NA positive ND MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-40 ND NA ND NA ND NA ND NA positive ND MW-107 ND NA ND NA NA NA NA NA positive ND MW-51-79 ND NA ND NA ND NA ND NA positive ND MW-111 6.79E+00 NA ND ND ND NA NA NA 1.36E+01 6.79E+00 MW-51-104 ND NA ND NA ND NA ND NA positive ND U3-4D ND NA ND NA ND NA ND NA positive ND MW-51-135 ND NA ND NA ND NA ND NA positive ND U3-4S NA NA ND NA ND NA NA NA positive ND MW-51-163 ND NA ND NA ND NA ND NA positive ND U3-T1 ND NA ND NA ND NA ND NA positive ND MW-51-189 ND NA ND NA ND NA 3.77E+01**

NA positive ND U3-T2 ND NA ND NA ND NA ND NA positive ND MW-52-11 ND NA ND NA NA NA NA NA positive ND U1-CSS ND NA ND NA ND NA NA NA positive ND MW-52-18 ND NA ND NA NA NA NA NA positive ND U1-NCD ND NA 1.14E+04 NA 1.20E+04 NA NA NA 1.17E+04 MW-52-48 ND NA ND NA NA NA NA NA positive ND U1-SFDS ND NA 2.09E+01 NA 7.99E+00 NA NA NA 1.44E+01 MW-52-64 ND NA ND NA NA NA NA NA positive ND I-2 NA NA ND NA ND NA NA NA positive ND MW-52-122 ND NA NA NA NA NA NA NA positive ND LAF-002 NA ND NA NA ND NA NA NA positive ND MW-52-162 ND NA ND NA NA NA NA NA positive ND B-1 9.79E+00 NA 2.27E+01 NA 1.89E+01 NA 2.15E+01 NA 1.82E+01 MW-52-181 ND NA ND NA NA NA NA NA positive ND B-6 NA ND NA ND ND NA ND NA ND MH-5 VCFD NA ND ND ND/ND ND NA ND NA ND Notes:

4) ** The Q1 2011 MW-40-100, MW-40-127 and MW-51-189 Cs-137 results were verified by re-analysis. However, based on the available chemistry and Site hydrogeologic data, these values do not appear to be representative of the groundwater conditions at these sampling intervals.

Well ID Cesium Results (pCi/L) 2011 Investigation Level Rolling Annual Average Cesium Results (pCi/L)

3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.

Rolling Annual Average

2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.

Well ID 2011 Investigation Level shaded value Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 2010 2010 2010 2010 2010 2010 2011 2011 2010 2010 2010 2010 2010 2010 2011 2011 MW-30-69 ND ND ND ND/ND ND NA ND ND positive ND MW-53-82 ND NA ND NA ND NA ND NA positive ND MW-30-84 ND ND ND ND/ND ND NA ND ND positive ND MW-53-120 ND NA ND NA ND NA ND NA positive ND MW-31-49 ND ND ND ND/ND ND NA ND ND positive ND MW-54-37 ND NA ND NA ND NA ND NA positive ND MW-31-63 ND ND ND ND/ND ND NA ND ND positive ND MW-54-58 ND NA ND NA ND NA ND NA positive ND MW-31-85 ND ND ND ND/ND ND NA ND ND positive ND MW-54-123 ND NA ND NA ND NA ND NA positive ND MW-32-48 ND NA ND ND NA NA NA NA positive ND MW-54-144 ND NA ND NA ND NA ND NA positive ND MW-32-59 ND ND ND ND/ND ND NA ND ND positive ND MW-54-173 ND NA ND NA ND NA ND NA positive ND MW-32-85 ND ND ND ND/ND ND NA ND ND positive ND MW-54-190 ND NA ND NA ND NA ND NA positive ND MW-32-149 ND ND ND ND/ND ND NA ND ND positive ND MW-55-24 ND NA ND NA ND NA ND NA positive ND MW-32-173 ND ND ND ND/ND ND NA ND ND positive ND MW-55-35 ND NA ND NA ND NA ND NA positive ND MW-32-190 ND ND ND ND/ND ND NA ND ND positive ND MW-55-54 ND NA ND NA ND NA ND NA positive ND MW-33 ND NA ND ND NA NA NA NA positive ND MW-56-53 ND NA ND NA ND NA ND NA positive ND MW-35 NA ND NA NA NA NA NA NA positive ND MW-56-83 ND NA ND NA ND NA ND NA positive ND MW-36-24 ND NA ND NA ND NA ND NA positive ND MW-57-11 ND NA ND NA NA NA ND NA positive ND MW-36-41 ND NA ND NA ND NA ND NA positive ND MW-57-20 ND NA ND NA NA NA ND NA positive ND MW-36-52 ND NA ND NA ND NA ND NA positive ND MW-57-45 ND NA ND NA NA NA ND NA positive ND MW-37-22 ND NA ND NA ND NA ND NA positive ND MW-58-26 ND NA ND NA ND NA ND NA positive ND MW-37-32 ND NA ND NA ND NA ND NA positive ND MW-58-65 ND NA ND NA ND NA ND NA positive ND MW-37-40 ND NA ND NA ND NA ND NA positive ND MW-60-35 ND ND ND NA ND NA ND NA positive ND MW-37-57 ND NA ND NA ND NA ND NA positive ND MW-60-53 ND ND ND NA ND NA ND NA positive ND MW-39-67 ND NA ND NA ND NA ND NA positive ND MW-60-72 ND ND ND NA ND NA ND NA positive ND MW-39-84 ND NA ND NA ND NA ND NA positive ND MW-60-135 ND ND ND NA ND NA ND NA positive ND MW-39-102 ND NA ND NA ND NA ND NA positive ND MW-60-154 ND ND ND NA ND NA ND NA positive ND MW-39-124 ND NA ND NA ND NA ND NA positive ND MW-60-176 ND ND ND NA ND NA ND NA positive ND MW-39-183 ND NA ND NA ND NA ND NA positive ND MW-62-18 ND NA ND NA ND NA ND NA positive ND MW-39-195 ND NA ND NA ND NA ND NA positive ND MW-62-37 ND NA ND NA ND NA ND NA positive ND MW-40-27 ND NA ND NA ND NA ND NA positive ND MW-62-53 ND NA ND NA ND NA ND NA positive ND MW-40-46 ND NA ND NA ND NA ND NA positive ND MW-62-71 ND NA ND NA ND NA ND NA positive ND MW-40-81 ND NA ND NA ND NA ND NA positive ND MW-62-92 ND NA ND NA ND NA ND NA positive ND MW-40-100 ND NA ND NA ND NA ND NA positive ND MW-62-138 ND NA ND NA ND NA ND NA positive ND MW-40-127 ND NA ND NA ND NA ND NA positive ND MW-62-182 ND NA ND NA ND NA ND NA positive ND MW-40-162 ND NA ND NA ND NA ND NA positive ND MW-63-18 ND NA ND NA ND NA ND NA positive ND MW-41-40 ND NA ND NA ND NA ND NA positive ND MW-63-34 ND NA ND NA ND NA ND NA positive ND MW-41-63 ND NA ND NA ND NA ND NA positive ND MW-63-50 ND NA ND NA ND NA ND NA positive ND MW-42-49 ND NA ND NA ND NA ND NA positive ND MW-63-93 ND NA ND NA ND NA ND NA positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-112 ND NA ND NA ND NA ND NA positive ND MW-43-28 ND NA ND NA ND NA ND NA positive ND MW-63-121 ND NA ND NA ND NA ND NA positive ND MW-43-62 ND NA ND NA ND NA ND NA positive ND MW-63-163 ND NA ND NA ND NA ND NA positive ND MW-44-66 ND ND ND NA ND NA ND NA positive ND MW-63-174 ND NA ND NA ND NA ND NA positive ND MW-44-102 ND ND ND NA ND NA ND NA positive ND MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-45-42 ND NA ND NA ND NA ND NA positive ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-45-61 ND NA ND NA ND NA ND NA positive ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-46 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND NA ND NA ND NA positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND NA ND NA ND NA positive ND MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-40 ND NA ND NA ND NA ND NA positive ND MW-107 ND NA ND NA NA NA ND NA positive ND MW-51-79 ND NA ND NA ND NA ND NA positive ND MW-111 ND NA ND ND ND NA ND NA positive ND MW-51-104 ND NA ND NA ND NA ND NA positive ND U3-4D ND NA ND NA ND NA ND NA positive ND MW-51-135 ND NA ND NA ND NA ND NA positive ND U3-4S NA NA ND NA ND NA ND NA positive ND MW-51-163 ND NA ND NA ND NA ND NA positive ND U3-T1 ND NA ND NA ND NA ND NA positive ND MW-51-189 ND NA ND NA ND NA ND NA positive ND U3-T2 ND NA ND NA ND NA ND NA positive ND MW-52-11 ND NA ND NA NA NA ND NA positive ND U1-CSS ND NA ND NA ND NA ND NA positive ND MW-52-18 ND NA ND NA NA NA ND NA positive ND U1-NCD NA NA NA NA ND NA ND NA ND MW-52-48 ND NA ND NA NA NA ND NA positive ND U1-SFDS NA NA NA NA ND NA ND NA ND MW-52-64 ND NA ND NA NA NA ND NA positive ND I-2 NA NA ND NA ND NA ND NA positive ND MW-52-122 ND NA NA NA NA NA ND NA positive ND LAF-002 NA ND NA NA ND NA ND NA positive ND MW-52-162 ND NA ND NA NA NA ND NA positive ND B-1 ND NA ND NA ND NA ND NA ND MW-52-181 ND NA ND NA NA NA ND NA positive ND B-6 NA ND ND NA ND NA ND NA ND MH-5 VCFD NA ND ND ND/ND ND NA ND NA ND Notes:

Well ID Cobalt Results (pCi/L) 2011 Investigation Level Rolling Annual Average 2011 Investigation Level Cobalt Results (pCi/L)

3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.

Rolling Annual Average

2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.

Well ID shaded value Unit 3 SFP Evap. Washout to MH-A2 - 3/25/09(initial)

Localized Transient Releases (Surface Spills and Washout)

Well ID Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 2010 2010 2010 2010 2010 2010 2011 2011 2010 2010 2010 2010 2010 2010 2011 2011 MW-30-69 NA NA NA NA NA NA NA NA positive NA MW-53-82 ND ND ND NA NA NA ND NA positive ND MW-30-84 NA NA NA NA NA NA NA NA positive NA MW-53-120 ND ND ND NA NA NA ND NA positive ND MW-31-49 NA NA NA NA NA NA NA NA positive NA MW-54-37 ND ND ND NA ND NA ND NA positive ND MW-31-63 NA NA NA NA NA NA NA NA positive NA MW-54-58 ND ND ND NA ND NA ND NA positive ND MW-31-85 NA NA NA NA NA NA NA NA positive NA MW-54-123 ND ND ND NA ND NA ND NA positive ND MW-32-48 NA NA NA NA NA NA NA NA positive NA MW-54-144 ND ND ND NA ND NA ND NA positive ND MW-32-59 NA NA NA NA NA NA NA NA positive NA MW-54-173 ND ND ND NA ND NA ND NA positive ND MW-32-85 NA NA NA NA NA NA NA NA positive NA MW-54-190 ND ND ND NA ND NA ND NA positive ND MW-32-149 NA NA NA NA NA NA NA NA positive NA MW-55-24 ND ND ND NA ND NA ND NA positive ND MW-32-173 NA NA NA NA NA NA NA NA positive NA MW-55-35 ND ND ND NA ND NA ND NA positive ND MW-32-190 NA NA NA NA NA NA NA NA positive NA MW-55-54 ND ND ND NA ND NA ND NA positive ND MW-33 NA NA NA NA NA NA NA NA positive NA MW-56-53 NA NA NA NA NA NA NA NA positive NA MW-35 NA NA NA NA NA NA NA NA positive NA MW-56-83 NA NA NA NA NA NA NA NA positive NA MW-36-24 NA NA NA NA NA NA NA NA positive NA MW-57-11 ND NA NA NA NA NA NA NA positive ND MW-36-41 NA NA NA NA NA NA NA NA positive NA MW-57-20 ND NA NA NA NA NA NA NA positive ND MW-36-52 NA NA NA NA NA NA NA NA positive NA MW-57-45 ND NA NA NA NA NA NA NA positive ND MW-37-22 NA NA NA NA NA NA NA NA positive NA MW-58-26 NA NA NA NA NA NA NA NA positive NA MW-37-32 NA NA NA NA NA NA NA NA positive NA MW-58-65 NA NA NA NA NA NA NA NA positive NA MW-37-40 NA NA NA NA NA NA NA NA positive NA MW-60-35 NA ND ND NA ND NA ND NA positive ND MW-37-57 NA NA NA NA NA NA NA NA positive NA MW-60-53 NA ND ND NA ND NA ND NA positive ND MW-39-67 NA NA NA NA NA NA NA NA positive NA MW-60-72 NA ND ND NA ND NA ND NA positive ND MW-39-84 NA NA NA NA NA NA NA NA positive NA MW-60-135 NA ND ND NA ND NA ND NA positive ND MW-39-102 NA NA NA NA NA NA NA NA positive NA MW-60-154 NA ND ND NA ND NA ND NA positive ND MW-39-124 NA NA NA NA NA NA NA NA positive NA MW-60-176 NA ND ND NA ND NA ND NA positive ND MW-39-183 NA NA NA NA NA NA NA NA positive NA MW-62-18 NA NA NA NA NA NA NA NA positive NA MW-39-195 NA NA NA NA NA NA NA NA positive NA MW-62-37 NA NA NA NA NA NA NA NA positive NA MW-40-27 NA NA NA NA NA NA NA NA positive NA MW-62-53 NA NA NA NA NA NA NA NA positive NA MW-40-46 NA NA NA NA NA NA NA NA positive NA MW-62-71 NA NA NA NA NA NA NA NA positive NA MW-40-81 NA NA NA NA NA NA NA NA positive NA MW-62-92 NA NA NA NA NA NA NA NA positive NA MW-40-100 NA NA NA NA NA NA NA NA positive NA MW-62-138 NA NA NA NA NA NA NA NA positive NA MW-40-127 NA NA NA NA NA NA NA NA positive NA MW-62-182 NA NA NA NA NA NA NA NA positive NA MW-40-162 NA NA NA NA NA NA NA NA positive NA MW-63-18 NA NA NA NA NA NA NA NA positive NA MW-41-40 NA NA NA NA NA NA NA NA positive NA MW-63-34 NA NA NA NA NA NA NA NA positive NA MW-41-63 NA NA NA NA NA NA NA NA positive NA MW-63-50 NA NA NA NA NA NA NA NA positive NA MW-42-49 2.36E+02 NA 1.77E+02 NA 2.24E+02 NA 3.02E+02 NA 6.74E+02 2.35E+02 MW-63-93 NA NA NA NA NA NA NA NA positive NA MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-112 NA NA NA NA NA NA NA NA positive NA MW-43-28 NA NA NA NA NA NA NA NA positive NA MW-63-121 NA NA NA NA NA NA NA NA positive NA MW-43-62 NA NA NA NA NA NA NA NA positive NA MW-63-163 NA NA NA NA NA NA NA NA positive NA MW-44-66 NA NA NA NA NA NA NA NA positive NA MW-63-174 NA NA NA NA NA NA NA NA positive NA MW-44-102 NA NA NA NA NA NA NA NA positive NA MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-45-42 NA NA NA NA NA NA NA NA positive NA MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-45-61 NA NA NA NA NA NA NA NA positive NA MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-46 NA NA NA NA NA NA NA NA positive NA MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND NA ND NA ND NA positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND NA ND NA ND NA positive ND MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-40 NA NA NA NA NA NA NA NA positive NA MW-107 NA NA NA NA NA NA NA NA positive NA MW-51-79 NA NA NA NA NA NA NA NA positive NA MW-111 NA NA NA NA NA NA NA NA positive NA MW-51-104 NA NA NA NA NA NA NA NA positive NA U3-4D NA NA NA NA NA NA NA NA positive NA MW-51-135 NA NA NA NA NA NA NA NA positive NA U3-4S NA NA NA NA NA NA NA NA positive NA MW-51-163 NA NA NA NA NA NA NA NA positive NA U3-T1 NA NA NA NA NA NA NA NA positive NA MW-51-189 NA NA NA NA NA NA NA NA positive NA U3-T2 NA NA NA NA NA NA NA NA positive NA MW-52-11 NA NA NA NA NA NA NA NA positive NA U1-CSS ND NA NA NA ND NA NA NA positive ND MW-52-18 NA NA NA NA NA NA NA NA positive NA U1-NCD NA NA 2.90E+02 NA 2.31E+02 NA NA NA 2.61E+02 MW-52-48 NA NA NA NA NA NA NA NA positive NA U1-SFDS NA NA ND NA ND NA NA NA ND MW-52-64 NA NA NA NA NA NA NA NA positive NA I-2 NA NA NA NA NA NA NA NA positive NA MW-52-122 NA NA NA NA NA NA NA NA positive NA LAF-002 NA ND NA NA ND NA NA NA positive ND MW-52-162 NA NA NA NA NA NA NA NA positive NA B-1 NA NA NA NA NA NA NA NA NA MW-52-181 NA NA NA NA NA NA NA NA positive NA B-6 NA NA NA NA NA NA NA NA NA MH-5 VCFD NA NA NA NA NA NA NA NA NA Notes:

3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.

Rolling Annual Average

2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.

Well ID Nickel Results (pCi/L)

Investigation Level Rolling Annual Average Investigation Level Nickel Results (pCi/L) shaded value ENT00575E Submitted: October 2, 2012

G

^

XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XY XYXY XY XYXY XYXY XYXY XY XYXY XY XYXY XY XY XY XYXY XY XY XYXY XY XY XY XYXY XYXY XYXY XY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XY XY XY XYXY XYXY XY XY XYXY XYXY XYXY XY XY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XY XYXY XYXY XYXY XY XYXY X

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

? @

?

?

? @

?

?

?

?

?

?

?

?

?

?

?

?

?

?

Storage storage Gravel Gravel Storage No Access Grass Earth Parking Asphalt Asphalt curb Asphalt parking Asphalt Concrete curbs Concrete curb Concrete Concrete curb Wooden curb Grass A/C UNIT Handicap ramp A/C unit on concrete Stone curbs Asphalt drive Asphalt parking Asphalt parking Asphalt parking Asphalt parking Asphalt curb Shrubs Trans.

Transformer area and switch gear Storage Containers A/C Units Grass Concrete curb Grass Shrubs Open gr ate Tank Asphalt drive Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt drive Asphalt Asphalt Drive Gravel Gravel Transformer yard Asphalt Drive this Area No Access Asphalt Conc rete Retaining Wa ll Stone retaining wall Gravel parking Gravel parking Gravel parking Gravel parking Stone curbs Stone curbs Asphalt parking Concrete curb Asphalt parking Concrete curb curb pad Asphalt curb Asphalt curb Asphalt parking Grass Asphalt curb Asphalt curb Grass Asphalt curb Asphalt parking Gravel parking Storage Storage Tank Fuel Oil Grass Asphalt drive Storage units Gravel Parking lot Asphalt Tank Overhead walkway Concrete curb Asphalt parking Asphalt parking Asphalt Asphalt Asphalt Asphalt Concrete pier Courtyard Asphalt Rip-rap 110 140 120 130 30 30 40 50 30 40 50 90 70 70 80 90 80 80 90 100 110 110 110 110 120 120 100 70 60 70 80 90 60 80 90 100 100 0

110 140 140 Transformer Gravel Storage Tank Fuel Oil Tank Tank Tank Covered Concrete Asphalt parking Condensate Tank Transformers on raised Concrete Pad Trans.

Transformers Concrete slab Tank Grass Transformers on raised Concrete Pad Tank Concrete Bridge Concrete Bridge Storage Tank Transformer Substation "H" Trailer Trans Tank Storage Tank Tank Pit Asphalt Trans Trans Trans Storage Tanks Asphalt Grass Vent pit Mach.

stand Unit 2 Condensate Storage Tank Liquid Nitrogen Transformers Yard (Gravel)

DISCHARGE OUTFALL CANAL Tank Gravel Shrubs Shrubs Shrubs Overhead Crane Grass FUEL TRAN SFE R PO O L STO RA GE PO O L STO RA GE PO O L FA IL ED FU EL AUX. PO O L DIS ASS EM B LY PO O L CAS K L O AD PO O L CAS K W AS H &

DIS ASS EM B LY ISO L ATIO N PI T PU MP SU CTI ON WELL WATER STO RA GE PO O L ROOF DRAIN ELEVATION 65' 43.8' 43.8' 43.8' 21.75' 22.75' (EL.=0.0) 33' 13' 43.8' 33' 33' 33' 33' 33' 42.5' 42.5' MH-4 MH-4A MH-5 MH-6 MH-2 B6 B6A B5 B4 B4A B3 B3A B2A B2 B1 A2 A1 U3-MH-14 F5 A2A CB-B CB-E CB-F C-1 C-3 D2 B7 B8 CB-33 CB-34 CB-15 CB-14 CB-13 CB-32 CB-31 CB-30 A7 U1-CB-22 U3-CB (U1-CB-10)

CB-29 U3-CB (U1-CB-9)

U1-CB-21 U1-CB-20 CB-28 CB-24 CB-27 E16 E16 E16A CB-6 CB-5A (CB-6)

CB-5B CB-7 CB-5 MH16 CB-3B CB3A CB4 CB-2C CB3 CB-2B CB-2A CB-2 CB-1 MH18 MH8 MH17 MH7 MH23A CB-16 MH9 MH10 MH11 MH22 MH21 MH13 MH3 MH12 MH1 CB-18 MH15 CB-19 CB-23 MH14 C2 E7 E6 E8 E9 E10 E11 E5 E5A E4 E4 E4A E3B E3 E3A F3 F4 CB E2 E2A F6 F7 E2B E2C E1 A6 A5 A3A A3 A4 E14 E15 E15A (U1-CB-8)

AB E13 E12 D1 CB-17 F2 F1 CB-12 MH-23 MH-19 MH-20 ROOF DRAIN Turbine Generator Building 2 Turbine Generator Building 1 Turbine Generator Building 3 Transformer Yard PAB Water Storage Tank FUEL POOL UNIT 2 1,015' 640' WEST FUEL POOL UNIT 1 UNIT 3 Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co UTILITY TUNNEL UTILITY TUNNEL CSS CSS TRENCH Cs Ni Co Cs Ni Co Cs Ni Co 50 40 30 20 10 5

50 40 30 20 5

20 13 10 Cs Ni Co B-1 Cs Ni Co B-6 ALL EYW AY U1-SFDS Cs Ni Co U1-NCD Cs Ni Co Cs Ni Co MH-5 VCFD 2

2 2

2 2

4 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

5 6

I-2 HR-1 U3-3 U3-2 U3-1 RW-1 OUT-1 U3-C1 U2-C1 MW-67 MW-66 MW-37 MW-36 MW-35 MW-34 MW-33 U3-4S U3-4D MW-52 MW-51 MW-50 MW-49 MW-47 MW-46 MW-45 MW-44 MW-42 MW-41 MW-38 MW-32 MW-31 MW-40 MW-48 MW-43 MW-39 U3-T2 U3-T1 MW-65 MW-62 MW-60 MW-59 MW-58 MW-57 MW-56 MW-55 MW-54 MW-53 MW-30 MW-64 MW-61 MW-63 U1-CSS MW-105 MW-101 MW-110 MW-111 MW-112 MW-109 MW-108 MW-107 H U D S O N R I V E R ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 20.9 64.6 34.8 9.13 44.8 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 34 0.1 8.3 7.2 7.05 9.77

-1.3 4.68 5.16 6.14 6.02 8.44 3.69 3.76 9.02 0.81 8.94 2.69 3.81 7.88 1.22 33.9 22.7 21.9 10.6 3.13 3.29 6.97 4.06 5.76 6.41 7.45 9.05 8.82 9.02 9.92 2.34 7.06 6.46 7.19 5.55 6.04 5.64 0.49 0.68 0.47 2.52 0.47 0.16 2.04 45.79 39.64 11.53 12.16 44.48 12.81 35.07 34.43 41.21 44.13 50.75

-1.64

-0.15

-0.48 29.36 37.68 36.03 40.36 49.24 40.66 43.87 44.32 46.83 52.35 54.22 32.72 23.79 24.43 24.79 25.12 25.21 26.96 30.71 31.76 32.15 25.45 26.68 21.08 22.37 25.16 29.05 10.48 10.54 10.68 12.36 11.71 10.27

-1.19

-1.54

-0.86

-2.26

-0.98

-1.24

-0.13

-0.08

-1.79

-1.69

-1.85

-0.37

-0.85

-1.24

-0.84

-0.15

-0.12

-1.93

-0.14

-0.86

-0.82

-0.02

-1.56

-1.02

-2.59

-2.25

-0.91

-2.03 115.76 DRY ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 260.5 ND ND ND ND ND ND ND 11700 24275 14.445 ND ND ND ND ND ND ND ND 9.45 0.29 21.51 ND ND ND ND ND 223.25 Plant North N

N 50 0

50 100 150 25 Feet Figure No.:

Job No.:

Dwg. Date:

Proj. Mgr.: MJB Designed By: MJB Reviewed By: MJB Operator: GAS 01.0017869.92 8-Q2 INDIAN POINT ENERGY CENTER BUCHANAN, NEW YORK GZA GeoEnvironmental, Inc.

One Edgewater Drive Norwood, MA 02062 Phone: (781) 278-3700 Fax: (781) 278-5701 2nd QUARTER 2011 ROLLING AVERAGE CESIUM, COBALT, AND NICKEL ACTIVITY MAP 1

2nd QUARTER 2011 ROLLING AVERAGE CESIUM, COBALT, AND NICKEL ACTIVITY MAP 1

East Fuel Pool LEGEND Cesium Data1 Average Cs, pCi/L Cobalt Data1 Average Co, pCi/L Nickel Data 1 Average Ni, pCi/L Not Detected (ND)

ND - 10 10 - 50 50 - 500 500 - 1,000 1,000 - 5,000

> 5,000 No Depth-Specific Samples ND 4.2 37 294 836 4460 6000 Not Detected (ND)

ND - 25 25 - 100 100 - 200 200 - 300 300 - 500

> 500 No Depth-Specific Samples ND 4

83 194 250 350 508 Not Detected (ND)

ND - 12 12 - 25 25 - 50 50 - 100 100 - 250 250 - 500

> 500 No Depth-Specific Samples ND 4

20 49 54 207 300 526 Groundwater Elevation Contours Depth-Specific Data Probable Legacy Release SSCs MW-30 Boring / Monitoring Installation Designation Longterm Radionuclide Monitoring Installation

?

Standby Radionuclide Monitoring Installation

?

Unit 1 West Fuel Pool (All U1-SFPs drained and inactive as of October 2008)

Unit 2 Fuel Pool (All identified leaks repaired as of December 2007)

Containment Spray Sump Trench Terminated Connection To Storm Drain Drain Exfiltration Inter-Structure Joint / Mud Mat Contours Other Than 10' Interval 20 5

11.3 11.9 12.6 12.8 Screened in Soil Screened in Bedrock Multiple Screened Intervals w/ Depth 6000 836 294 Average activity of Cs 137 (pCi/L) for each screened interval.

37 508 250 194 4

526 207 49 20 Average activity of Co 60 (pCi/L) for each screened interval.

Average activity of Ni 63 (pCi/L) for each screened interval.

3 Transient Distillate Tank Valve Leak in Unit 1 Fuel Storage Building - 3/07/2009 G

4 Footing Drain Active Storm Drain Catch Basin Abandoned Storm Drain Ambient "Watertable" Contours for Q4 2008 (11/11/2008) 1 1

Groundwater elevation for each screened interval at time of low river tide for Q4 2008 (11/11/2008).

1 1

^

Transient Spill from Temporary R.O. Skid Piping -

Entered MW-32 Vault and MH 11/21/2009 5

Notes:

1. Groundwater contours drawn from Q4 2008 groundwater data to show groundwater conditions used for recalibration of the Precipitation Mass Balance Model (see Q2 2009 LTM Report). These contours developed from limited data recorded on 11/11/2008. Actual elevations may vary from conditions shown and the actual distribution of piezometric heads is likely more complex than indicated.

Data Notes:

1. Average Cesium, Cobalt, and Nickel activity values are yearly rolling arithmetic averages of the current and preceeding three quarters' data.

Only values greater than the MDC are used in this average, thus adding a degree of conservatism to the subsequent dose computations.

2. Storm or foundation drain sampling locations, for which investigation levels are not applicable.
3. Historically elevated Tritium levels in MW-42-49 obsrved during Q1 2009 were consistent with leakage visually identified on 03/07/2009 (and terminated immediately thereafter) from the waste distillate tank valves located within the Unit 1 fuel storage building. Elevated tritium levels not seen in MW-53; therefore, this transient leakage was likely to have been generally confined to, and contained by, the Unit 1 North Curtain Drain.
4. Historically elevated Tritium levels in MW-45-42 observed during Q2 2009 were consistent with an increased activity observed in Unit 3 Manhole A2. This release was initially detected in a storm drain sample collected 03/25/2009 under the 80-10 Effluents Program. This Tritium peak dissipated prior to samples taken during the subsequent quarter. Additionally, transient Tritium peaks have been recently detected in MH-A2 from Q3 2010 to Q2 2011. These increases are consistent with elevated Tritium levels in MW-41-40, MW-46 and B-1. Based on investigations initiated in, and ongoing since, 2009 and the more recent sampling of the Unit 3 Fuel Storage Building (FSB) roof drains, it has been concluded that these increases in storm drain and monitoring well Tritium activity are due to condensation of SFP evaporation on the FSB roof (Washout) when the exhaust fan is not operating, which then enters the roof drains and discharges directly into MH-A2 during rainfall events.
5. Elevated levels of Tritium detected in MH-9 and MH-10a during routine 80-10 Effluents Program sampling on 1/15/2010 appears to have originated from a November 21, 2009 transient leak in temporary RWST / R.O. skid connection hoses, which flowed into MH-9. It also appears that this release entered the well vault for MW-32, and may have penetrated the well casings and entered the subsurface around the monitoring installation.
6. Elevated levels of Tritium initially detected in U1-CSS, MW-39, MW-46, MW-54, MW-56 and MW-57 during the Q2-2011 sampling event appear to have originated from a Q2 2011 sample sink overflow and subsequent floor flooding in a Unit 1 Chemical Systems Building sample room on the 53 elevation.

General Notes:

1. Base map was developed from an untitled electronic file provided by Badey and Watson Surveying and Engineering, P.C., Dated 2/3/06; CAD file name : "GZA.dwg".

© 2012 - GZA GeoEnvironmental, Inc. \\\\gzanor\\Jobs\\17,000-18,999\\17869\\17869-91.MG\\Figures\\GIS\\MXD Documents\\2011-comb\\12-08-30 F08 Q2 2011 Rolling Average Cesium, Cobalt, and Nickel Activity Map 17869-92_final.mxd, 9/14/2012, 8:35:54 AM, jennifer.pisani 09-14-2012 Sample Sink Overflow - Unit 1 Chemical Systems Building Q2 2011 6

Unit 3 SFP Evap. Washout to MH-A2 - 3/25/09 XX X X

Localized Transient Releases (Surface Spills and Washout)

(initial)

Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3

Quarter 4 Post Quarter 4

Quarter 1 Post Quarter 1

Quarter 2 Post Quarter 2 2010 2010 2010 2010 2011 2011 2011 2011 2010 2010 2010 2010 2011 2011 2011 2011 MW-30-69 ND ND/ND ND NA ND ND ND ND positive ND MW-54-37 ND NA ND NA ND NA ND ND positive ND MW-30-84 ND ND/ND ND NA ND ND ND ND positive ND MW-54-58 ND NA ND NA ND NA ND ND positive ND MW-31-49 ND ND/ND ND NA ND ND ND NA positive ND MW-54-123 ND NA ND NA ND NA ND ND positive ND MW-31-63 ND ND/ND ND NA ND ND ND NA positive ND MW-54-144 ND NA ND NA ND NA ND ND positive ND MW-31-85 ND ND/ND ND NA ND ND ND NA positive ND MW-54-173 ND NA ND NA ND NA ND ND positive ND MW-32-48 ND ND NA NA NA NA NA NA positive ND MW-54-190 NA NA ND NA ND NA ND ND positive ND MW-32-59 ND ND/ND ND NA ND ND ND NA positive ND MW-55-24 ND NA ND NA ND NA NA NA positive ND MW-32-85 ND ND/ND ND NA ND ND ND NA positive ND MW-55-35 ND NA ND NA ND NA NA NA positive ND MW-32-149 ND ND/ND ND NA ND ND ND NA positive ND MW-55-54 ND NA ND NA ND NA NA NA positive ND MW-32-173 ND ND/ND ND NA ND ND ND NA positive ND MW-56-53 ND NA ND NA NA NA ND ND positive ND MW-32-190 ND ND/ND ND NA ND ND ND NA positive ND MW-56-83 NA NA ND NA NA NA ND ND positive ND MW-33 ND ND NA NA NA NA NA NA positive ND MW-57-11 ND NA NA NA NA NA ND ND positive ND MW-35 NA NA NA NA NA NA NA NA positive NA MW-57-20 ND NA NA NA NA NA ND ND positive ND MW-36-24 ND NA ND NA ND NA ND NA positive ND MW-57-45 ND NA NA NA NA NA ND ND positive ND MW-36-41 ND NA ND NA ND NA ND NA positive ND MW-58-26 ND NA ND NA NA NA ND ND positive ND MW-36-52 ND NA ND NA ND NA ND NA positive ND MW-58-65 ND NA ND NA NA NA ND ND positive ND MW-37-22 ND NA ND NA ND NA ND NA positive ND MW-59-32 NA NA NA NA NA NA NA ND ND MW-37-32 ND NA ND NA ND NA ND NA positive ND MW-59-45 NA NA NA NA NA NA NA ND ND MW-37-40 ND NA ND NA ND NA ND NA positive ND MW-59-68 NA NA NA NA NA NA NA ND ND MW-37-57 ND NA ND NA ND NA ND NA positive ND MW-60-35 ND NA ND NA ND NA ND NA positive ND MW-39-67 ND NA ND NA NA NA ND ND positive ND MW-60-53 ND NA ND NA ND NA ND NA positive ND MW-39-84 ND NA ND NA NA NA ND ND positive ND MW-60-72 ND NA ND NA ND NA ND NA positive ND MW-39-102 ND NA ND NA NA NA 4.48E+01 ND positive 4.48E+01 MW-60-135 ND NA ND NA ND NA ND NA positive ND MW-39-124 ND NA ND NA NA NA 9.13E+00 ND positive 9.13E+00 MW-60-154 ND NA ND NA ND NA ND NA positive ND MW-39-183 ND NA ND NA NA NA ND ND positive ND MW-60-176 ND NA ND NA ND NA ND NA positive ND MW-39-195 ND NA ND NA NA NA ND ND positive ND MW-62-18 ND NA ND NA ND NA ND ND positive ND MW-40-27 ND NA ND NA ND NA ND NA positive ND MW-62-37 ND NA ND NA ND NA ND ND positive ND MW-40-46 ND NA ND NA ND NA ND NA positive ND MW-62-53 ND NA ND NA ND NA ND ND positive ND MW-40-81 ND NA ND NA ND NA ND NA positive ND MW-62-71 ND NA ND NA ND NA ND ND positive ND MW-40-100 ND NA ND NA 2.46E+01***

NA ND NA positive ND MW-62-92 ND NA ND NA ND NA ND ND positive ND MW-40-127 ND NA ND NA 5.07E+01***

NA ND NA positive ND MW-62-138 ND NA ND NA ND NA ND ND positive ND MW-40-162 ND NA ND NA ND NA ND NA positive ND MW-62-182 ND NA ND NA ND NA ND ND positive ND MW-41-40 ND NA ND NA ND NA ND ND positive ND MW-63-18 ND NA ND NA ND NA ND ND positive ND MW-41-63 ND NA ND NA ND NA ND ND positive ND MW-63-34 ND NA ND NA ND NA ND ND positive ND MW-42-49 1.87E+04 NA 2.39E+04 NA 3.30E+04 NA 2.15E+04 NA 6.58E+04 2.43E+04 MW-63-50 ND NA ND NA ND NA ND ND positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-93 ND NA ND NA ND NA ND ND positive ND MW-43-28 ND NA ND NA ND NA ND NA positive ND MW-63-112 ND NA ND NA ND NA ND ND positive ND MW-43-62 ND NA ND NA ND NA ND NA positive ND MW-63-121 ND NA ND NA ND NA ND ND positive ND MW-44-66 NA NA ND NA ND NA ND ND positive ND MW-63-163 ND NA ND NA ND NA ND ND positive ND MW-44-102 ND NA ND NA ND NA ND ND positive ND MW-63-174 ND NA ND NA ND NA ND ND positive ND MW-45-42 ND NA ND NA ND NA ND ND positive ND MW-65-48 NA NA NA NA NA NA NA ND ND MW-45-61 ND NA ND NA ND NA ND ND positive ND MW-65-80 NA NA NA NA NA NA NA ND ND MW-46 ND NA ND NA ND NA ND ND positive ND MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-47-56 NA NA NA NA NA NA NA ND ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-47-80 NA NA NA NA NA NA NA ND ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND NA ND NA ND ND positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND NA ND NA ND ND positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-51-40 ND NA ND NA ND NA ND NA positive ND MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-79 ND NA ND NA ND NA ND NA positive ND MW-107 ND NA NA NA NA NA ND NA positive ND MW-51-104 ND NA ND NA ND NA ND NA positive ND MW-108 NA NA NA NA NA NA NA ND ND MW-51-135 ND NA ND NA ND NA ND NA positive ND MW-109 NA NA NA NA NA NA NA ND ND MW-51-163 ND NA ND NA ND NA ND NA positive ND MW-111 ND ND ND NA NA NA NA NA 1.36E+01 ND MW-51-189 ND NA ND NA 3.77E+01***

NA ND NA positive ND U3-3 NA NA NA NA NA NA NA ND ND MW-52-11 ND NA NA NA NA NA ND ND positive ND U3-4D ND NA ND NA ND NA ND ND positive ND MW-52-18 ND NA NA NA NA NA ND ND positive ND U3-4S ND NA ND NA NA NA ND ND positive ND MW-52-48 ND NA NA NA NA NA ND ND positive ND U3-T1 ND NA ND NA ND NA ND NA positive ND MW-52-64 ND NA NA NA NA NA ND ND positive ND U3-T2 ND NA ND NA ND NA ND ND positive ND MW-52-122 NA NA NA NA NA NA 3.48E+01 ND positive 3.48E+01 U1-CSS ND NA ND NA NA NA ND ND positive ND MW-52-162 ND NA NA NA NA NA ND ND positive ND U1-NCD 1.14E+04 NA 1.20E+04 NA NA NA NA NA 1.17E+04 MW-52-181 ND NA NA NA NA NA 6.46E+01 ND positive 6.46E+01 U1-SFDS 2.09E+01 NA 7.99E+00 NA NA NA NA NA 1.44E+01 MW-53-82 ND NA ND NA ND NA ND NA positive ND I-2 ND NA ND NA NA NA NA NA positive ND MW-53-120 ND NA ND NA ND NA ND NA positive ND LAF-002 NA NA ND NA NA NA ND NA positive ND B-1 2.27E+01 NA 1.89E+01 NA 2.15E+01 NA 2.05E+01 NA 2.09E+01 B-6 NA ND ND NA ND NA ND ND ND MH-5 VCFD ND ND/ND ND NA ND NA ND ND****

ND

6) **** Four Post-Q2 2011 MH-5 VCFD samples were collected. All four samples were ND for Cs-137.
2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.
4) ** Indicates 2011 I.L. not computed for this well due to absence of 2010 data.

Cesium Results (pCi/L)

Rolling Annual Average Well ID

1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.

Investigation Level

5) *** The Q1 2011 MW-40-100, MW-40-127 and MW-51-189 Cs-137 results were verified by re-analysis. However, based on the available chemistry and Site hydrogeologic data, these values do not appear to be representative of the groundwater conditions at these sampling intervals.

Well ID Cesium Results (pCi/L)

Investigation Level Rolling Annual Average Notes:

shaded value Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 2010 2010 2010 2010 2011 2011 2011 2011 2010 2010 2010 2010 2011 2011 2011 2011 MW-30-69 ND ND/ND ND NA ND ND ND ND positive ND MW-54-37 ND NA ND NA ND NA ND ND positive ND MW-30-84 ND ND/ND ND NA ND ND ND ND positive ND MW-54-58 ND NA ND NA ND NA ND ND positive ND MW-31-49 ND ND/ND ND NA ND ND ND NA positive ND MW-54-123 ND NA ND NA ND NA ND ND positive ND MW-31-63 ND ND/ND ND NA ND ND ND NA positive ND MW-54-144 ND NA ND NA ND NA ND ND positive ND MW-31-85 ND ND/ND ND NA ND ND ND NA positive ND MW-54-173 ND NA ND NA ND NA ND ND positive ND MW-32-48 ND ND NA NA NA NA NA NA positive ND MW-54-190 ND NA ND NA ND NA ND ND positive ND MW-32-59 ND ND/ND ND NA ND ND ND NA positive ND MW-55-24 ND NA ND NA ND NA NA NA positive ND MW-32-85 ND ND/ND ND NA ND ND ND NA positive ND MW-55-35 ND NA ND NA ND NA NA NA positive ND MW-32-149 ND ND/ND ND NA ND ND ND NA positive ND MW-55-54 ND NA ND NA ND NA NA NA positive ND MW-32-173 ND ND/ND ND NA ND ND ND NA positive ND MW-56-53 ND NA ND NA ND NA ND ND positive ND MW-32-190 ND ND/ND ND NA ND ND ND NA positive ND MW-56-83 ND NA ND NA ND NA ND ND positive ND MW-33 ND ND NA NA NA NA NA NA positive ND MW-57-11 ND NA NA NA ND NA ND ND positive ND MW-35 NA NA NA NA NA NA NA NA positive NA MW-57-20 ND NA NA NA ND NA ND ND positive ND MW-36-24 ND NA ND NA ND NA ND NA positive ND MW-57-45 ND NA NA NA ND NA ND ND positive ND MW-36-41 ND NA ND NA ND NA ND NA positive ND MW-58-26 ND NA ND NA ND NA ND ND positive ND MW-36-52 ND NA ND NA ND NA ND NA positive ND MW-58-65 ND NA ND NA ND NA ND ND positive ND MW-37-22 ND NA ND NA ND NA ND NA positive ND MW-59-32 NA NA NA NA NA NA NA ND ND MW-37-32 ND NA ND NA ND NA ND NA positive ND MW-59-45 NA NA NA NA NA NA NA ND ND MW-37-40 ND NA ND NA ND NA ND NA positive ND MW-59-68 NA NA NA NA NA NA NA ND ND MW-37-57 ND NA ND NA ND NA ND NA positive ND MW-60-35 ND NA ND NA ND NA ND NA positive ND MW-39-67 ND NA ND NA ND NA ND ND positive ND MW-60-53 ND NA ND NA ND NA ND NA positive ND MW-39-84 ND NA ND NA ND NA ND ND positive ND MW-60-72 ND NA ND NA ND NA ND NA positive ND MW-39-102 ND NA ND NA ND NA ND ND positive ND MW-60-135 ND NA ND NA ND NA ND NA positive ND MW-39-124 ND NA ND NA ND NA ND ND positive ND MW-60-154 ND NA ND NA ND NA ND NA positive ND MW-39-183 ND NA ND NA ND NA ND ND positive ND MW-60-176 ND NA ND NA ND NA ND ND positive ND MW-39-195 ND NA ND NA ND NA ND ND positive ND MW-62-18 ND NA ND NA ND NA ND ND positive ND MW-40-27 ND NA ND NA ND NA ND NA positive ND MW-62-37 ND NA ND NA ND NA ND ND positive ND MW-40-46 ND NA ND NA ND NA ND NA positive ND MW-62-53 ND NA ND NA ND NA ND ND positive ND MW-40-81 ND NA ND NA ND NA ND NA positive ND MW-62-71 ND NA ND NA ND NA ND ND positive ND MW-40-100 ND NA ND NA ND NA ND NA positive ND MW-62-92 ND NA ND NA ND NA ND ND positive ND MW-40-127 ND NA ND NA ND NA ND NA positive ND MW-62-138 ND NA ND NA ND NA ND ND positive ND MW-40-162 ND NA ND NA ND NA ND NA positive ND MW-62-182 ND NA ND NA ND NA ND ND positive ND MW-41-40 ND NA ND NA ND NA ND ND positive ND MW-63-18 ND NA ND NA ND NA ND ND positive ND MW-41-63 ND NA ND NA ND NA ND ND positive ND MW-63-34 ND NA ND NA ND NA ND ND positive ND MW-42-49 ND NA ND NA ND NA ND NA positive ND MW-63-50 ND NA ND NA ND NA ND ND positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-93 ND NA ND NA ND NA ND ND positive ND MW-43-28 ND NA ND NA ND NA ND NA positive ND MW-63-112 ND NA ND NA ND NA ND ND positive ND MW-43-62 ND NA ND NA ND NA ND NA positive ND MW-63-121 ND NA ND NA ND NA ND ND positive ND MW-44-66 ND NA ND NA ND NA ND ND positive ND MW-63-163 ND NA ND NA ND NA ND ND positive ND MW-44-102 ND NA ND NA ND NA ND ND positive ND MW-63-174 ND NA ND NA ND NA ND ND positive ND MW-45-42 ND NA ND NA ND NA ND ND positive ND MW-65-48 NA NA NA NA NA NA NA ND ND MW-45-61 ND NA ND NA ND NA ND ND positive ND MW-65-80 NA NA NA NA NA NA NA ND ND MW-46 ND NA ND NA ND NA ND ND positive ND MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-47-56 NA NA NA NA NA NA NA ND ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-47-80 NA NA NA NA NA NA NA ND ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND NA ND NA ND ND positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND NA ND NA ND ND positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-51-40 ND NA ND NA ND NA ND NA positive ND MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-79 ND NA ND NA ND NA ND NA positive ND MW-107 ND NA NA NA ND NA ND NA positive ND MW-51-104 ND NA ND NA ND NA ND NA positive ND MW-108 NA NA NA NA NA NA NA ND ND MW-51-135 ND NA ND NA ND NA ND NA positive ND MW-109 NA NA NA NA NA NA NA ND ND MW-51-163 ND NA ND NA ND NA ND NA positive ND MW-111 ND ND ND NA ND NA NA ND positive ND MW-51-189 ND NA ND NA ND NA ND NA positive ND U3-3 NA NA NA NA NA NA NA ND ND MW-52-11 ND NA NA NA ND NA ND ND positive ND U3-4D ND NA ND NA ND NA ND ND positive ND MW-52-18 ND NA NA NA ND NA ND ND positive ND U3-4S ND NA ND NA ND NA ND ND positive ND MW-52-48 ND NA NA NA ND NA ND ND positive ND U3-T1 ND NA ND NA ND NA ND NA positive ND MW-52-64 ND NA NA NA ND NA ND ND positive ND U3-T2 ND NA ND NA ND NA ND ND positive ND MW-52-122 NA NA NA NA ND NA ND ND positive ND U1-CSS ND NA ND NA ND NA ND ND positive ND MW-52-162 ND NA NA NA ND NA ND ND positive ND U1-NCD NA NA ND NA ND NA NA NA ND MW-52-181 ND NA NA NA ND NA ND ND positive ND U1-SFDS NA NA ND NA ND NA NA NA ND MW-53-82 ND NA ND NA ND NA ND NA positive ND I-2 ND NA ND NA ND NA NA NA positive ND MW-53-120 ND NA ND NA ND NA ND NA positive ND LAF-002 NA NA ND NA ND NA ND NA positive ND B-1 ND NA ND NA ND NA ND NA ND B-6 ND NA ND NA ND NA ND ND ND MH-5 VCFD ND ND/ND ND NA ND NA ND ND***

ND

6) *** Four Post-Q2 2011 MH-5 VCFD samples were collected. All four samples were ND for Co-60.
2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.
4) ** Indicates 2011 I.L. not computed for this well due to absence of 2010 data.

Well ID Investigation Level Cobalt Results (pCi/L)

Rolling Annual Average

1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.

Well ID Cobalt Results (pCi/L)

Investigation Level Rolling Annual Average Notes:

shaded value Well ID Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 2010 2010 2010 2010 2011 2011 2011 2011 2010 2010 2010 2010 2011 2011 2011 2011 MW-30-69 NA NA NA NA NA NA NA NA positive NA MW-54-37 ND NA ND NA ND NA ND ND positive ND MW-30-84 NA NA NA NA NA NA NA NA positive NA MW-54-58 ND NA ND NA ND NA ND ND positive ND MW-31-49 NA NA NA NA NA NA NA NA positive NA MW-54-123 ND NA ND NA ND NA ND ND positive ND MW-31-63 NA NA NA NA NA NA NA NA positive NA MW-54-144 ND NA ND NA ND NA ND ND positive ND MW-31-85 NA NA NA NA NA NA NA NA positive NA MW-54-173 ND NA ND NA ND NA ND ND positive ND MW-32-48 NA NA NA NA NA NA NA NA positive NA MW-54-190 ND NA ND NA ND NA ND ND positive ND MW-32-59 NA NA NA NA NA NA NA NA positive NA MW-55-24 ND NA ND NA ND NA NA NA positive ND MW-32-85 NA NA NA NA NA NA NA NA positive NA MW-55-35 ND NA ND NA ND NA NA NA positive ND MW-32-149 NA NA NA NA NA NA NA NA positive NA MW-55-54 ND NA ND NA ND NA NA NA positive ND MW-32-173 NA NA NA NA NA NA NA NA positive NA MW-56-53 NA NA NA NA NA NA NA ND positive ND MW-32-190 NA NA NA NA NA NA NA NA positive NA MW-56-83 NA NA NA NA NA NA NA ND positive ND MW-33 NA NA NA NA NA NA NA NA positive NA MW-57-11 NA NA NA NA NA NA ND ND positive ND MW-35 NA NA NA NA NA NA NA NA positive NA MW-57-20 NA NA NA NA NA NA ND ND positive ND MW-36-24 NA NA NA NA NA NA NA NA positive NA MW-57-45 NA NA NA NA NA NA ND ND positive ND MW-36-41 NA NA NA NA NA NA NA NA positive NA MW-58-26 NA NA NA NA NA NA NA ND positive ND MW-36-52 NA NA NA NA NA NA NA NA positive NA MW-58-65 NA NA NA NA NA NA NA ND positive ND MW-37-22 NA NA NA NA NA NA NA NA positive NA MW-59-32 NA NA NA NA NA NA NA ND ND MW-37-32 NA NA NA NA NA NA NA NA positive NA MW-59-45 NA NA NA NA NA NA NA ND ND MW-37-40 NA NA NA NA NA NA NA NA positive NA MW-59-68 NA NA NA NA NA NA NA ND ND MW-37-57 NA NA NA NA NA NA NA NA positive NA MW-60-35 ND NA ND NA ND NA ND NA positive ND MW-39-67 NA NA NA NA NA NA NA NA positive NA MW-60-53 ND NA ND NA ND NA ND NA positive ND MW-39-84 NA NA NA NA NA NA NA NA positive NA MW-60-72 ND NA ND NA ND NA ND NA positive ND MW-39-102 NA NA NA NA NA NA NA NA positive NA MW-60-135 ND NA ND NA ND NA ND NA positive ND MW-39-124 NA NA NA NA NA NA NA NA positive NA MW-60-154 ND NA ND NA ND NA ND NA positive ND MW-39-183 NA NA NA NA NA NA NA NA positive NA MW-60-176 ND NA ND NA ND NA ND NA positive ND MW-39-195 NA NA NA NA NA NA NA NA positive NA MW-62-18 NA NA NA NA NA NA NA ND positive ND MW-40-27 NA NA NA NA NA NA NA NA positive NA MW-62-37 NA NA NA NA NA NA NA ND positive ND MW-40-46 NA NA NA NA NA NA NA NA positive NA MW-62-53 NA NA NA NA NA NA NA ND positive ND MW-40-81 NA NA NA NA NA NA NA NA positive NA MW-62-71 NA NA NA NA NA NA NA ND positive ND MW-40-100 NA NA NA NA NA NA NA NA positive NA MW-62-92 NA NA NA NA NA NA NA ND positive ND MW-40-127 NA NA NA NA NA NA NA NA positive NA MW-62-138 NA NA NA NA NA NA NA ND positive ND MW-40-162 NA NA NA NA NA NA NA NA positive NA MW-62-182 NA NA NA NA NA NA NA ND positive ND MW-41-40 NA NA NA NA NA NA NA NA positive NA MW-63-18 NA NA NA NA NA NA NA ND positive ND MW-41-63 NA NA NA NA NA NA NA NA positive NA MW-63-34 NA NA NA NA NA NA NA ND positive ND MW-42-49 1.77E+02 NA 2.24E+02 NA 3.02E+02 NA 1.90E+02 NA 6.74E+02 2.23E+02 MW-63-50 NA NA NA NA NA NA NA ND positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-93 NA NA NA NA NA NA NA ND positive ND MW-43-28 NA NA NA NA NA NA NA NA positive NA MW-63-112 NA NA NA NA NA NA NA ND positive ND MW-43-62 NA NA NA NA NA NA NA NA positive NA MW-63-121 NA NA NA NA NA NA NA ND positive ND MW-44-66 NA NA NA NA NA NA NA NA positive NA MW-63-163 NA NA NA NA NA NA NA ND positive ND MW-44-102 NA NA NA NA NA NA NA NA positive NA MW-63-174 NA NA NA NA NA NA NA ND positive ND MW-45-42 NA NA NA NA NA NA NA NA positive NA MW-65-48 NA NA NA NA NA NA NA ND ND MW-45-61 NA NA NA NA NA NA NA NA positive NA MW-65-80 NA NA NA NA NA NA NA ND ND MW-46 NA NA NA NA NA NA NA NA positive NA MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-47-56 NA NA NA NA NA NA NA ND ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-47-80 NA NA NA NA NA NA NA ND ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND NA ND NA ND ND positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND NA ND NA ND ND positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-51-40 NA NA NA NA NA NA NA NA positive NA MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-79 NA NA NA NA NA NA NA NA positive NA MW-107 NA NA NA NA NA NA NA NA positive NA MW-51-104 NA NA NA NA NA NA NA NA positive NA MW-108 NA NA NA NA NA NA NA ND ND MW-51-135 NA NA NA NA NA NA NA NA positive NA MW-109 NA NA NA NA NA NA NA ND ND MW-51-163 NA NA NA NA NA NA NA NA positive NA MW-111 NA NA NA NA NA NA NA NA positive NA MW-51-189 NA NA NA NA NA NA NA NA positive NA U3-3 NA NA NA NA NA NA NA NA NA MW-52-11 NA NA NA NA NA NA NA NA positive NA U3-4D NA NA NA NA NA NA NA NA positive NA MW-52-18 NA NA NA NA NA NA NA NA positive NA U3-4S NA NA NA NA NA NA NA NA positive NA MW-52-48 NA NA NA NA NA NA NA NA positive NA U3-T1 NA NA NA NA NA NA NA NA positive NA MW-52-64 NA NA NA NA NA NA NA NA positive NA U3-T2 NA NA NA NA NA NA NA NA positive NA MW-52-122 NA NA NA NA NA NA NA NA positive NA U1-CSS NA NA ND NA NA NA ND ND positive ND MW-52-162 NA NA NA NA NA NA NA NA positive NA U1-NCD 2.90E+02 NA 2.31E+02 NA NA NA NA NA 2.61E+02 MW-52-181 NA NA NA NA NA NA NA NA positive NA U1-SFDS ND NA ND NA NA NA NA NA ND MW-53-82 ND NA NA NA ND NA ND NA positive ND I-2 NA NA NA NA NA NA NA NA positive NA MW-53-120 ND NA NA NA ND NA ND NA positive ND LAF-002 NA NA ND NA NA NA ND NA positive ND B-1 NA NA NA NA NA NA NA NA NA B-6 NA NA NA NA NA NA NA NA NA MH-5 VCFD NA NA NA NA NA NA NA NA NA Investigation Level Nickel Results (pCi/L)

3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.

Rolling Annual Average

1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.
2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
4) ** Indicates 2011 I.L. not computed for this well due to absence of 2010 data.

Well ID Nickel Results (pCi/L)

Investigation Level Rolling Annual Average Notes:

shaded value

G

^

XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XY XYXY XY XYXY XYXY XYXY XY XYXY XY XYXY XY XY XY XYXY XY XY XYXY XY XY XY XYXY XYXY XYXY XY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XY XY XY XYXY XYXY XY XY XYXY XYXY XYXY XY XY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XY XYXY XYXY XYXY XY XYXY X

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

? @

?

?

? @

?

?

?

?

?

?

?

?

?

?

?

?

?

?

Storage storage Gravel Gravel Storage No Access Grass Earth Parking Asphalt Asphalt curb Asphalt parking Asphalt Concrete curbs Concrete curb Concrete Concrete curb Wooden curb Grass A/C UNIT Handicap ramp A/C unit on concrete Stone curbs Asphalt drive Asphalt parking Asphalt parking Asphalt parking Asphalt parking Asphalt curb Shrubs Trans.

Transformer area and switch gear Storage Containers A/C Units Grass Concrete curb Grass Shrubs Open gr ate Tank Asphalt drive Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt drive Asphalt Asphalt Drive Gravel Gravel Transformer yard Asphalt Drive this Area No Access Asphalt Conc rete Retaining Wa ll Stone retaining wall Gravel parking Gravel parking Gravel parking Gravel parking Stone curbs Stone curbs Asphalt parking Concrete curb Asphalt parking Concrete curb curb pad Asphalt curb Asphalt curb Asphalt parking Grass Asphalt curb Asphalt curb Grass Asphalt curb Asphalt parking Gravel parking Storage Storage Tank Fuel Oil Grass Asphalt drive Storage units Gravel Parking lot Asphalt Tank Overhead walkway Concrete curb Asphalt parking Asphalt parking Asphalt Asphalt Asphalt Asphalt Concrete pier Courtyard Asphalt Rip-rap 110 140 120 130 30 30 40 50 30 40 50 90 70 70 80 90 80 80 90 100 110 110 110 110 120 120 100 70 60 70 80 90 60 80 90 100 100 0

110 140 140 Transformer Gravel Storage Tank Fuel Oil Tank Tank Tank Covered Concrete Asphalt parking Condensate Tank Transformers on raised Concrete Pad Trans.

Transformers Concrete slab Tank Grass Transformers on raised Concrete Pad Tank Concrete Bridge Concrete Bridge Storage Tank Transformer Substation "H" Trailer Trans Tank Storage Tank Tank Pit Asphalt Trans Trans Trans Storage Tanks Asphalt Grass Vent pit Mach.

stand Unit 2 Condensate Storage Tank Liquid Nitrogen Transformers Yard (Gravel)

DISCHARGE OUTFALL CANAL Tank Gravel Shrubs Shrubs Shrubs Overhead Crane Grass FUEL TRAN SFE R PO O L STO RA GE PO O L STO RA GE PO O L FA IL ED FU EL AUX. PO O L DIS ASS EM B LY PO O L CAS K L O AD PO O L CAS K W AS H &

DIS ASS EM B LY ISO L ATIO N PI T PU MP SU CTI ON WELL WATER STO RA GE PO O L ROOF DRAIN ELEVATION 65' 43.8' 43.8' 43.8' 21.75' 22.75' (EL.=0.0) 33' 13' 43.8' 33' 33' 33' 33' 33' 42.5' 42.5' MH-4 MH-4A MH-5 MH-6 MH-2 B6 B6A B5 B4 B4A B3 B3A B2A B2 B1 A2 A1 U3-MH-14 F5 A2A CB-B CB-E CB-F C-1 C-3 D2 B7 B8 CB-33 CB-34 CB-15 CB-14 CB-13 CB-32 CB-31 CB-30 A7 U1-CB-22 U3-CB (U1-CB-10)

CB-29 U3-CB (U1-CB-9)

U1-CB-21 U1-CB-20 CB-28 CB-24 CB-27 E16 E16 E16A CB-6 CB-5A (CB-6)

CB-5B CB-7 CB-5 MH16 CB-3B CB3A CB4 CB-2C CB3 CB-2B CB-2A CB-2 CB-1 MH18 MH8 MH17 MH7 MH23A CB-16 MH9 MH10 MH11 MH22 MH21 MH13 MH3 MH12 MH1 CB-18 MH15 CB-19 CB-23 MH14 C2 E7 E6 E8 E9 E10 E11 E5 E5A E4 E4 E4A E3B E3 E3A F3 F4 CB E2 E2A F6 F7 E2B E2C E1 A6 A5 A3A A3 A4 E14 E15 E15A (U1-CB-8)

AB E13 E12 D1 CB-17 F2 F1 CB-12 MH-23 MH-19 MH-20 ROOF DRAIN Turbine Generator Building 2 Turbine Generator Building 1 Turbine Generator Building 3 Transformer Yard PAB Water Storage Tank FUEL POOL UNIT 2 1,015' 640' WEST FUEL POOL UNIT 1 UNIT 3 Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co UTILITY TUNNEL UTILITY TUNNEL CSS CSS TRENCH Cs Ni Co Cs Ni Co Cs Ni Co 50 40 30 20 10 5

50 40 30 20 5

20 13 10 Cs Ni Co B-1 Cs Ni Co B-6 ALL EYW AY U1-SFDS Cs Ni Co U1-NCD Cs Ni Co Cs Ni Co MH-5 VCFD 2

2 2

2 2

4 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

5 6

I-2 HR-1 U3-3 U3-2 U3-1 RW-1 OUT-1 U3-C1 U2-C1 MW-67 MW-66 MW-37 MW-36 MW-35 MW-34 MW-33 U3-4S U3-4D MW-52 MW-51 MW-50 MW-49 MW-47 MW-46 MW-45 MW-44 MW-42 MW-41 MW-38 MW-32 MW-31 MW-40 MW-48 MW-43 MW-39 U3-T2 U3-T1 MW-65 MW-62 MW-60 MW-59 MW-58 MW-57 MW-56 MW-55 MW-54 MW-53 MW-30 MW-64 MW-61 MW-63 U1-CSS MW-105 MW-101 MW-110 MW-111 MW-112 MW-109 MW-108 MW-107 H U D S O N R I V E R ND ND 19 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 8385 8.61 64.6 34.8 9.13 44.8 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 34 0.1 8.3 7.2 7.05 9.77

-1.3 4.68 5.16 6.14 6.02 8.44 3.69 3.76 9.02 0.81 8.94 2.69 3.81 7.88 1.22 33.9 22.7 21.9 10.6 3.13 3.29 6.97 4.06 5.76 6.41 7.45 9.05 8.82 9.02 9.92 2.34 7.06 6.46 7.19 5.55 6.04 5.64 0.49 0.68 0.47 2.52 0.47 0.16 2.04 45.79 39.64 11.53 12.16 44.48 12.81 35.07 34.43 41.21 44.13 50.75

-1.64

-0.15

-0.48 29.36 37.68 36.03 40.36 49.24 40.66 43.87 44.32 46.83 52.35 54.22 32.72 23.79 24.43 24.79 25.12 25.21 26.96 30.71 31.76 32.15 25.45 26.68 21.08 22.37 25.16 29.05 10.48 10.54 10.68 12.36 11.71 10.27

-1.19

-1.54

-0.86

-2.26

-0.98

-1.24

-0.13

-0.08

-1.79

-1.69

-1.85

-0.37

-0.85

-1.24

-0.84

-0.15

-0.12

-1.93

-0.14

-0.86

-0.82

-0.02

-1.56

-1.02

-2.59

-2.25

-0.91

-2.03 115.76 DRY ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 249 172.5 ND ND ND ND ND ND ND 23525 ND ND ND ND ND ND ND ND 9.45 0.29 21.51 ND ND ND ND ND 14.5 Plant North N

N 50 0

50 100 150 25 Feet Figure No.:

Job No.:

Dwg. Date:

Proj. Mgr.: MJB Designed By: MJB Reviewed By: MJB Operator: GAS 01.0017869.92 8-Q3 INDIAN POINT ENERGY CENTER BUCHANAN, NEW YORK GZA GeoEnvironmental, Inc.

One Edgewater Drive Norwood, MA 02062 Phone: (781) 278-3700 Fax: (781) 278-5701 3rd QUARTER 2011 ROLLING AVERAGE CESIUM, COBALT, AND NICKEL ACTIVITY MAP 1

3rd QUARTER 2011 ROLLING AVERAGE CESIUM, COBALT, AND NICKEL ACTIVITY MAP 1

East Fuel Pool LEGEND Cesium Data1 Average Cs, pCi/L Cobalt Data1 Average Co, pCi/L Nickel Data 1 Average Ni, pCi/L Not Detected (ND)

ND - 10 10 - 50 50 - 500 500 - 1,000 1,000 - 5,000

> 5,000 No Depth-Specific Samples ND 4.2 37 294 836 4460 6000 Not Detected (ND)

ND - 25 25 - 100 100 - 200 200 - 300 300 - 500

> 500 No Depth-Specific Samples ND 4

83 194 250 350 508 Not Detected (ND)

ND - 12 12 - 25 25 - 50 50 - 100 100 - 250 250 - 500

> 500 No Depth-Specific Samples ND 4

20 49 54 207 300 526 Groundwater Elevation Contours Depth-Specific Data Probable Legacy Release SSCs MW-30 Boring / Monitoring Installation Designation Longterm Radionuclide Monitoring Installation

?

Standby Radionuclide Monitoring Installation

?

Unit 1 West Fuel Pool (All U1-SFPs drained and inactive as of October 2008)

Unit 2 Fuel Pool (All identified leaks repaired as of December 2007)

Containment Spray Sump Trench Terminated Connection To Storm Drain Drain Exfiltration Inter-Structure Joint / Mud Mat Contours Other Than 10' Interval 20 5

11.3 11.9 12.6 12.8 Screened in Soil Screened in Bedrock Multiple Screened Intervals w/ Depth 6000 836 294 Average activity of Cs 137 (pCi/L) for each screened interval.

37 508 250 194 4

526 207 49 20 Average activity of Co 60 (pCi/L) for each screened interval.

Average activity of Ni 63 (pCi/L) for each screened interval.

3 Transient Distillate Tank Valve Leak in Unit 1 Fuel Storage Building - 3/07/2009 G

4 Footing Drain Active Storm Drain Catch Basin Abandoned Storm Drain Ambient "Watertable" Contours for Q4 2008 (11/11/2008) 1 1

Groundwater elevation for each screened interval at time of low river tide for Q4 2008 (11/11/2008).

1 1

^

Transient Spill from Temporary R.O. Skid Piping -

Entered MW-32 Vault and MH 11/21/2009 5

Notes:

1. Groundwater contours drawn from Q4 2008 groundwater data to show groundwater conditions used for recalibration of the Precipitation Mass Balance Model (see Q2 2009 LTM Report). These contours developed from limited data recorded on 11/11/2008. Actual elevations may vary from conditions shown and the actual distribution of piezometric heads is likely more complex than indicated.

Data Notes:

1. Average Cesium, Cobalt, and Nickel activity values are yearly rolling arithmetic averages of the current and preceeding three quarters' data.

Only values greater than the MDC are used in this average, thus adding a degree of conservatism to the subsequent dose computations.

2. Storm or foundation drain sampling locations, for which investigation levels are not applicable.
3. Historically elevated Tritium levels in MW-42-49 obsrved during Q1 2009 were consistent with leakage visually identified on 03/07/2009 (and terminated immediately thereafter) from the waste distillate tank valves located within the Unit 1 fuel storage building. Elevated tritium levels not seen in MW-53; therefore, this transient leakage was likely to have been generally confined to, and contained by, the Unit 1 North Curtain Drain.
4. Historically elevated Tritium levels in MW-45-42 observed during Q2 2009 were consistent with an increased activity observed in Unit 3 Manhole A2. This release was initially detected in a storm drain sample collected 03/25/2009 under the 80-10 Effluents Program. This Tritium peak dissipated prior to samples taken during the subsequent quarter. Additionally, transient Tritium peaks have been recently detected in MH-A2 from Q3 2010 to Q3 2011. These increases are consistent with elevated Tritium levels in MW-41-40, MW-46 and B-1. Based on investigations initiated in, and ongoing since, 2009 and the more recent sampling of the Unit 3 Fuel Storage Building (FSB) roof drains, it has been concluded that these increases in storm drain and monitoring well Tritium activity are due to condensation of SFP evaporation on the FSB roof (Washout) when the exhaust fan is not operating, which then enters the roof drains and discharges directly into MH-A2 during rainfall events. As such, Entergy placed the FSB vent fan back in service on 7-21-2011 and the Tritium activity returned to baseline conditions within 2 weeks.
5. Elevated levels of Tritium detected in MH-9 and MH-10a during routine 80-10 Effluents Program sampling on 1/15/2010 appears to have originated from a November 21, 2009 transient leak in temporary RWST / R.O. skid connection hoses, which flowed into MH-9. It also appears that this release entered the well vault for MW-32, and may have penetrated the well casings and entered the subsurface around the monitoring installation.
6. Elevated levels of Tritium initially detected in U1-CSS, MW-39, MW-46, MW-54, MW-56 and MW-57 during the Q2-2011 sampling event appear to have originated from a Q2 2011 sample sink overflow and subsequent floor flooding in a Unit 1 Chemical Systems Building sample room on the 53 elevation.

General Notes:

1. Base map was developed from an untitled electronic file provided by Badey and Watson Surveying and Engineering, P.C., Dated 2/3/06; CAD file name : "GZA.dwg".

© 2012 - GZA GeoEnvironmental, Inc. \\\\gzanor\\Jobs\\17,000-18,999\\17869\\17869-91.MG\\Figures\\GIS\\MXD Documents\\2011-comb\\12-09-14 F08 Q3 2011 Rolling Average Cesium, Cobalt, and Nickel Activity Map 17869-92_final.mxd, 9/14/2012, 4:58:13 PM, jennifer.pisani 09-14-2012 Sample Sink Overflow - Unit 1 Chemical Systems Building Q2 2011 6

Unit 3 SFP Evap. Washout to MH-A2 - 3/25/09 XX X X

Localized Transient Releases (Surface Spills and Washout)

(initial)

Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4

Quarter 1 Post Quarter 1

Quarter 2 Post Quarter 2

Quarter 3 Post Quarter 3 2010 2010 2011 2011 2011 2011 2011 2011 2010 2010 2011 2011 2011 2011 2011 2011 MW-30-69 ND NA ND ND ND ND ND NA positive ND MW-54-37 ND NA ND NA ND ND ND NA positive ND MW-30-84 ND NA ND ND ND ND ND NA positive ND MW-54-58 ND NA ND NA ND ND ND NA positive ND MW-31-49 ND NA ND ND ND NA ND NA positive ND MW-54-123 ND NA ND NA ND ND ND NA positive ND MW-31-63 ND NA ND ND ND NA ND NA positive ND MW-54-144 ND NA ND NA ND ND ND NA positive ND MW-31-85 ND NA ND ND ND NA ND NA positive ND MW-54-173 ND NA ND NA ND ND ND NA positive ND MW-32-48 NA NA NA NA NA NA NA NA positive NA MW-54-190 ND NA ND NA ND ND ND NA positive ND MW-32-59 ND NA ND ND ND NA ND NA positive ND MW-55-24 ND NA ND NA NA NA ND NA positive ND MW-32-85 ND NA ND ND ND NA ND NA positive ND MW-55-35 ND NA ND NA NA NA ND NA positive ND MW-32-149 ND NA ND ND ND NA ND NA positive ND MW-55-54 ND NA ND NA NA NA ND NA positive ND MW-32-173 ND NA ND ND ND NA ND NA positive ND MW-56-53 ND NA NA NA ND ND NA ND positive ND MW-32-190 ND NA ND ND ND NA ND NA positive ND MW-56-83 ND NA NA NA ND ND NA ND positive ND MW-33 NA NA NA NA NA NA NA NA positive NA MW-57-11 NA NA NA NA ND ND NA ND positive ND MW-35 NA NA NA NA NA NA NA NA positive NA MW-57-20 NA NA NA NA ND ND NA ND positive ND MW-36-24 ND NA ND NA ND NA ND NA positive ND MW-57-45 NA NA NA NA ND ND NA ND positive ND MW-36-41 ND NA ND NA ND NA ND NA positive ND MW-58-26 ND NA NA NA ND ND NA ND positive ND MW-36-52 ND NA ND NA ND NA ND NA positive ND MW-58-65 ND NA NA NA ND ND NA ND positive ND MW-37-22 ND NA ND NA ND NA ND NA positive ND MW-59-32 NA NA NA NA NA ND NA ND ND MW-37-32 ND NA ND NA ND NA ND NA positive ND MW-59-45 NA NA NA NA NA ND NA ND ND MW-37-40 ND NA ND NA ND NA ND NA positive ND MW-59-68 NA NA NA NA NA ND NA ND ND MW-37-57 ND NA ND NA ND NA ND NA positive ND MW-60-35 ND NA ND NA ND NA ND NA positive ND MW-39-67 ND NA NA NA ND ND NA ND positive ND MW-60-53 ND NA ND NA ND NA ND NA positive ND MW-39-84 ND NA NA NA ND ND NA ND positive ND MW-60-72 ND NA ND NA ND NA ND NA positive ND MW-39-102 ND NA NA NA 4.48E+01 ND NA ND positive 4.48E+01 MW-60-135 ND NA ND NA ND NA ND NA positive ND MW-39-124 ND NA NA NA 9.13E+00 ND NA ND positive 9.13E+00 MW-60-154 ND NA ND NA ND NA ND NA positive ND MW-39-183 ND NA NA NA ND ND NA ND positive ND MW-60-176 ND NA ND NA ND NA ND NA positive ND MW-39-195 ND NA NA NA ND ND NA ND positive ND MW-62-18 ND NA ND NA ND ND ND NA positive ND MW-40-27 ND NA ND NA ND NA NA NA positive ND MW-62-37 ND NA ND NA ND ND ND NA positive ND MW-40-46 ND NA ND NA ND NA NA NA positive ND MW-62-53 ND NA ND NA ND ND ND NA positive ND MW-40-81 ND NA ND NA ND NA NA NA positive ND MW-62-71 ND NA ND NA ND ND ND NA positive ND MW-40-100 ND NA 2.46E+01***

NA ND NA NA NA positive ND MW-62-92 ND NA ND NA ND ND ND NA positive ND MW-40-127 ND NA 5.07E+01***

NA ND NA NA NA positive ND MW-62-138 ND NA ND NA ND ND ND NA positive ND MW-40-162 ND NA ND NA ND NA NA NA positive ND MW-62-182 ND NA ND NA ND ND ND NA positive ND MW-41-40 ND NA ND NA ND ND ND NA positive ND MW-63-18 ND NA ND NA ND ND ND NA positive ND MW-41-63 ND NA ND NA ND ND ND NA positive ND MW-63-34 ND NA ND NA ND ND ND NA positive ND MW-42-49 2.39E+04 NA 3.30E+04 NA 2.15E+04 NA 1.57E+04 NA 6.58E+04 2.35E+04 MW-63-50 ND NA ND NA ND ND ND NA positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-93 ND NA ND NA ND ND ND NA positive ND MW-43-28 ND NA ND NA ND NA ND NA positive ND MW-63-112 ND NA ND NA ND ND ND NA positive ND MW-43-62 ND NA ND NA ND NA ND NA positive ND MW-63-121 ND NA ND NA ND ND ND NA positive ND MW-44-66 ND NA ND NA ND ND ND NA positive ND MW-63-163 ND NA ND NA ND ND ND NA positive ND MW-44-102 ND NA ND NA ND ND ND NA positive ND MW-63-174 ND NA ND NA ND ND ND NA positive ND MW-45-42 ND NA ND NA ND ND NA ND positive ND MW-65-48 NA NA NA NA NA ND NA NA ND MW-45-61 ND NA ND NA ND ND NA ND positive ND MW-65-80 NA NA NA NA NA ND NA NA ND MW-46 ND NA ND NA ND ND ND NA positive ND MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-47-56 NA NA NA NA NA ND NA ND ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-47-80 NA NA NA NA NA ND NA ND ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND NA ND ND ND NA positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND NA ND ND ND NA positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-51-40 ND NA ND NA ND NA ND NA positive ND MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-79 ND NA ND NA ND NA ND NA positive ND MW-107 NA NA NA NA ND NA NA NA positive ND MW-51-104 ND NA ND NA ND NA ND NA positive ND MW-108 NA NA NA NA NA ND NA ND ND MW-51-135 ND NA ND NA ND NA ND NA positive ND MW-109 NA NA NA NA NA ND NA ND ND MW-51-163 ND NA ND NA ND NA ND NA positive ND MW-111 ND NA NA NA NA NA NA NA 1.36E+01 ND MW-51-189 ND NA 3.77E+01***

NA ND NA ND NA positive ND U3-3 NA NA NA NA NA ND NA ND ND MW-52-11 NA NA NA NA ND ND NA NA positive ND U3-4D ND NA ND NA ND ND ND NA positive ND MW-52-18 NA NA NA NA ND ND NA NA positive ND U3-4S ND NA NA NA ND ND ND NA positive ND MW-52-48 NA NA NA NA ND ND NA NA positive ND U3-T1 ND NA ND NA ND NA ND NA positive ND MW-52-64 NA NA NA NA ND ND NA NA positive ND U3-T2 ND NA ND NA ND ND ND NA positive ND MW-52-122 NA NA NA NA 3.48E+01 ND NA NA positive 3.48E+01 U1-CSS ND NA NA NA ND ND NA NA positive ND MW-52-162 NA NA NA NA ND ND NA NA positive ND U1-NCD 1.20E+04 NA NA NA NA NA 4.77E+03 NA 8.39E+03 MW-52-181 NA NA NA NA 6.46E+01 ND NA NA positive 6.46E+01 U1-SFDS 7.99E+00 NA NA NA NA NA 9.23E+00 NA 8.61E+00 MW-53-82 ND NA ND NA ND NA ND NA positive ND I-2 ND NA NA NA NA NA ND NA positive ND MW-53-120 ND NA ND NA ND NA ND NA positive ND LAF-002 ND NA NA NA ND NA NA NA positive ND B-1 1.89E+01 NA 2.15E+01 NA 2.05E+01 NA 1.51E+01 NA 1.90E+01 B-6 ND NA ND NA ND ND ND NA ND MH-5 VCFD ND NA ND NA ND ND****

ND_ND_ND ND_ND ND

6) **** Four Post-Q2 2011 MH-5 VCFD samples were collected. All four samples were ND for Cs-137.
2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.
4) ** Indicates 2011 I.L. not computed for this well due to absence of 2010 data.

Cesium Results (pCi/L)

Rolling Annual Average Well ID

1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.

Investigation Level

5) *** The Q1 2011 MW-40-100, MW-40-127 and MW-51-189 Cs-137 results were verified by re-analysis. However, based on the available chemistry and Site hydrogeologic data, these values do not appear to be representative of the groundwater conditions at these sampling intervals.

Well ID Cesium Results (pCi/L)

Investigation Level Rolling Annual Average Notes:

shaded value Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 2010 2010 2011 2011 2011 2011 2011 2011 2010 2010 2011 2011 2011 2011 2011 2011 MW-30-69 ND NA ND ND ND ND ND NA positive ND MW-54-37 ND NA ND NA ND ND ND NA positive ND MW-30-84 ND NA ND ND ND ND ND NA positive ND MW-54-58 ND NA ND NA ND ND ND NA positive ND MW-31-49 ND NA ND ND ND NA ND NA positive ND MW-54-123 ND NA ND NA ND ND ND NA positive ND MW-31-63 ND NA ND ND ND NA ND NA positive ND MW-54-144 ND NA ND NA ND ND ND NA positive ND MW-31-85 ND NA ND ND ND NA ND NA positive ND MW-54-173 ND NA ND NA ND ND ND NA positive ND MW-32-48 NA NA NA NA NA NA NA NA positive NA MW-54-190 ND NA ND NA ND ND ND NA positive ND MW-32-59 ND NA ND ND ND NA ND NA positive ND MW-55-24 ND NA ND NA NA NA ND NA positive ND MW-32-85 ND NA ND ND ND NA ND NA positive ND MW-55-35 ND NA ND NA NA NA ND NA positive ND MW-32-149 ND NA ND ND ND NA ND NA positive ND MW-55-54 ND NA ND NA NA NA ND NA positive ND MW-32-173 ND NA ND ND ND NA ND NA positive ND MW-56-53 ND NA ND NA ND ND NA ND positive ND MW-32-190 ND NA ND ND ND NA ND NA positive ND MW-56-83 ND NA ND NA ND ND NA ND positive ND MW-33 NA NA NA NA NA NA NA NA positive NA MW-57-11 NA NA ND NA ND ND NA ND positive ND MW-35 NA NA NA NA NA NA NA NA positive NA MW-57-20 NA NA ND NA ND ND NA ND positive ND MW-36-24 ND NA ND NA ND NA ND NA positive ND MW-57-45 NA NA ND NA ND ND NA ND positive ND MW-36-41 ND NA ND NA ND NA ND NA positive ND MW-58-26 ND NA ND NA ND ND NA ND positive ND MW-36-52 ND NA ND NA ND NA ND NA positive ND MW-58-65 ND NA ND NA ND ND NA ND positive ND MW-37-22 ND NA ND NA ND NA ND NA positive ND MW-59-32 NA NA NA NA NA ND NA ND ND MW-37-32 ND NA ND NA ND NA ND NA positive ND MW-59-45 NA NA NA NA NA ND NA ND ND MW-37-40 ND NA ND NA ND NA ND NA positive ND MW-59-68 NA NA NA NA NA ND NA ND ND MW-37-57 ND NA ND NA ND NA ND NA positive ND MW-60-35 ND NA ND NA ND NA ND NA positive ND MW-39-67 ND NA ND NA ND ND NA ND positive ND MW-60-53 ND NA ND NA ND NA ND NA positive ND MW-39-84 ND NA ND NA ND ND NA ND positive ND MW-60-72 ND NA ND NA ND NA ND NA positive ND MW-39-102 ND NA ND NA ND ND NA ND positive ND MW-60-135 ND NA ND NA ND NA ND NA positive ND MW-39-124 ND NA ND NA ND ND NA ND positive ND MW-60-154 ND NA ND NA ND NA ND NA positive ND MW-39-183 ND NA ND NA ND ND NA ND positive ND MW-60-176 ND NA ND NA ND ND ND NA positive ND MW-39-195 ND NA ND NA ND ND NA ND positive ND MW-62-18 ND NA ND NA ND ND ND NA positive ND MW-40-27 ND NA ND NA ND NA NA NA positive ND MW-62-37 ND NA ND NA ND ND ND NA positive ND MW-40-46 ND NA ND NA ND NA NA NA positive ND MW-62-53 ND NA ND NA ND ND ND NA positive ND MW-40-81 ND NA ND NA ND NA NA NA positive ND MW-62-71 ND NA ND NA ND ND ND NA positive ND MW-40-100 ND NA ND NA ND NA NA NA positive ND MW-62-92 ND NA ND NA ND ND ND NA positive ND MW-40-127 ND NA ND NA ND NA NA NA positive ND MW-62-138 ND NA ND NA ND ND ND NA positive ND MW-40-162 ND NA ND NA ND NA NA NA positive ND MW-62-182 ND NA ND NA ND ND ND NA positive ND MW-41-40 ND NA ND NA ND ND ND NA positive ND MW-63-18 ND NA ND NA ND ND ND NA positive ND MW-41-63 ND NA ND NA ND ND ND NA positive ND MW-63-34 ND NA ND NA ND ND ND NA positive ND MW-42-49 ND NA ND NA ND NA ND NA positive ND MW-63-50 ND NA ND NA ND ND ND NA positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-93 ND NA ND NA ND ND ND NA positive ND MW-43-28 ND NA ND NA ND NA ND NA positive ND MW-63-112 ND NA ND NA ND ND ND NA positive ND MW-43-62 ND NA ND NA ND NA ND NA positive ND MW-63-121 ND NA ND NA ND ND ND NA positive ND MW-44-66 ND NA ND NA ND ND ND NA positive ND MW-63-163 ND NA ND NA ND ND ND NA positive ND MW-44-102 ND NA ND NA ND ND ND NA positive ND MW-63-174 ND NA ND NA ND ND ND NA positive ND MW-45-42 ND NA ND NA ND ND NA ND positive ND MW-65-48 NA NA NA NA NA ND NA NA ND MW-45-61 ND NA ND NA ND ND NA ND positive ND MW-65-80 NA NA NA NA NA ND NA NA ND MW-46 ND NA ND NA ND ND ND NA positive ND MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-47-56 NA NA NA NA NA ND NA ND ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-47-80 NA NA NA NA NA ND NA ND ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND NA ND ND ND NA positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND NA ND ND ND NA positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-51-40 ND NA ND NA ND NA ND NA positive ND MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-79 ND NA ND NA ND NA ND NA positive ND MW-107 NA NA ND NA ND NA NA NA positive ND MW-51-104 ND NA ND NA ND NA ND NA positive ND MW-108 NA NA NA NA NA ND NA ND ND MW-51-135 ND NA ND NA ND NA ND NA positive ND MW-109 NA NA NA NA NA ND NA ND ND MW-51-163 ND NA ND NA ND NA ND NA positive ND MW-111 ND NA ND NA NA ND NA NA positive ND MW-51-189 ND NA ND NA ND NA ND NA positive ND U3-3 NA NA NA NA NA ND NA ND ND MW-52-11 NA NA ND NA ND ND NA NA positive ND U3-4D ND NA ND NA ND ND ND NA positive ND MW-52-18 NA NA ND NA ND ND NA NA positive ND U3-4S ND NA ND NA ND ND ND NA positive ND MW-52-48 NA NA ND NA ND ND NA NA positive ND U3-T1 ND NA ND NA ND NA ND NA positive ND MW-52-64 NA NA ND NA ND ND NA NA positive ND U3-T2 ND NA ND NA ND ND ND NA positive ND MW-52-122 NA NA ND NA ND ND NA NA positive ND U1-CSS ND NA ND NA ND ND NA NA positive ND MW-52-162 NA NA ND NA ND ND NA NA positive ND U1-NCD ND NA ND NA NA NA ND NA ND MW-52-181 NA NA ND NA ND ND NA NA positive ND U1-SFDS ND NA ND NA NA NA ND NA ND MW-53-82 ND NA ND NA ND NA ND NA positive ND I-2 ND NA ND NA NA NA ND NA positive ND MW-53-120 ND NA ND NA ND NA ND NA positive ND LAF-002 ND NA ND NA ND NA NA NA positive ND B-1 ND NA ND NA ND NA ND NA ND B-6 ND NA ND NA ND ND ND NA ND MH-5 VCFD ND NA ND NA ND ND***

ND_ND_ND ND_ND ND

6) *** Four Post-Q2 2011 MH-5 VCFD samples were collected. All four samples were ND for Co-60.
2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.
4) ** Indicates 2011 I.L. not computed for this well due to absence of 2010 data.

Well ID Investigation Level Cobalt Results (pCi/L)

Rolling Annual Average

1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.

Well ID Cobalt Results (pCi/L)

Investigation Level Rolling Annual Average Notes:

shaded value Well ID Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 2010 2010 2011 2011 2011 2011 2011 2011 2010 2010 2011 2011 2011 2011 2011 2011 MW-30-69 NA NA NA NA NA NA NA NA positive NA MW-54-37 ND NA ND NA ND ND ND NA positive ND MW-30-84 NA NA NA NA NA NA NA NA positive NA MW-54-58 ND NA ND NA ND ND ND NA positive ND MW-31-49 NA NA NA NA NA NA NA NA positive NA MW-54-123 ND NA ND NA ND ND ND NA positive ND MW-31-63 NA NA NA NA NA NA NA NA positive NA MW-54-144 ND NA ND NA ND ND ND NA positive ND MW-31-85 NA NA NA NA NA NA NA NA positive NA MW-54-173 ND NA ND NA ND ND ND NA positive ND MW-32-48 NA NA NA NA NA NA NA NA positive NA MW-54-190 ND NA ND NA ND ND ND NA positive ND MW-32-59 NA NA NA NA NA NA NA NA positive NA MW-55-24 ND NA ND NA NA NA ND NA positive ND MW-32-85 NA NA NA NA NA NA NA NA positive NA MW-55-35 ND NA ND NA NA NA ND NA positive ND MW-32-149 NA NA NA NA NA NA NA NA positive NA MW-55-54 ND NA ND NA NA NA ND NA positive ND MW-32-173 NA NA NA NA NA NA NA NA positive NA MW-56-53 NA NA NA NA NA ND NA NA positive ND MW-32-190 NA NA NA NA NA NA NA NA positive NA MW-56-83 NA NA NA NA NA ND NA NA positive ND MW-33 NA NA NA NA NA NA NA NA positive NA MW-57-11 NA NA NA NA ND ND NA ND positive ND MW-35 NA NA NA NA NA NA NA NA positive NA MW-57-20 NA NA NA NA ND ND NA ND positive ND MW-36-24 NA NA NA NA NA NA NA NA positive NA MW-57-45 NA NA NA NA ND ND NA ND positive ND MW-36-41 NA NA NA NA NA NA NA NA positive NA MW-58-26 NA NA NA NA NA ND NA NA positive ND MW-36-52 NA NA NA NA NA NA NA NA positive NA MW-58-65 NA NA NA NA NA ND NA NA positive ND MW-37-22 NA NA NA NA NA NA NA NA positive NA MW-59-32 NA NA NA NA NA ND NA ND ND MW-37-32 NA NA NA NA NA NA NA NA positive NA MW-59-45 NA NA NA NA NA ND NA ND ND MW-37-40 NA NA NA NA NA NA NA NA positive NA MW-59-68 NA NA NA NA NA ND NA ND ND MW-37-57 NA NA NA NA NA NA NA NA positive NA MW-60-35 ND NA ND NA ND NA NA NA positive ND MW-39-67 NA NA NA NA NA NA NA NA positive NA MW-60-53 ND NA ND NA ND NA NA NA positive ND MW-39-84 NA NA NA NA NA NA NA NA positive NA MW-60-72 ND NA ND NA ND NA NA NA positive ND MW-39-102 NA NA NA NA NA NA NA NA positive NA MW-60-135 ND NA ND NA ND NA NA NA positive ND MW-39-124 NA NA NA NA NA NA NA NA positive NA MW-60-154 ND NA ND NA ND NA NA NA positive ND MW-39-183 NA NA NA NA NA NA NA NA positive NA MW-60-176 ND NA ND NA ND NA NA NA positive ND MW-39-195 NA NA NA NA NA NA NA NA positive NA MW-62-18 NA NA NA NA NA ND NA NA positive ND MW-40-27 NA NA NA NA NA NA NA NA positive NA MW-62-37 NA NA NA NA NA ND NA NA positive ND MW-40-46 NA NA NA NA NA NA NA NA positive NA MW-62-53 NA NA NA NA NA ND NA NA positive ND MW-40-81 NA NA NA NA NA NA NA NA positive NA MW-62-71 NA NA NA NA NA ND NA NA positive ND MW-40-100 NA NA NA NA NA NA NA NA positive NA MW-62-92 NA NA NA NA NA ND NA NA positive ND MW-40-127 NA NA NA NA NA NA NA NA positive NA MW-62-138 NA NA NA NA NA ND NA NA positive ND MW-40-162 NA NA NA NA NA NA NA NA positive NA MW-62-182 NA NA NA NA NA ND NA NA positive ND MW-41-40 NA NA NA NA NA NA NA NA positive NA MW-63-18 NA NA NA NA NA ND NA NA positive ND MW-41-63 NA NA NA NA NA NA NA NA positive NA MW-63-34 NA NA NA NA NA ND NA NA positive ND MW-42-49 2.24E+02 NA 3.02E+02 NA 1.90E+02 NA 2.80E+02 NA 6.74E+02 2.49E+02 MW-63-50 NA NA NA NA NA ND NA NA positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-93 NA NA NA NA NA ND NA NA positive ND MW-43-28 NA NA NA NA NA NA NA NA positive NA MW-63-112 NA NA NA NA NA ND NA NA positive ND MW-43-62 NA NA NA NA NA NA NA NA positive NA MW-63-121 NA NA NA NA NA ND NA NA positive ND MW-44-66 NA NA NA NA NA NA NA NA positive NA MW-63-163 NA NA NA NA NA ND NA NA positive ND MW-44-102 NA NA NA NA NA NA NA NA positive NA MW-63-174 NA NA NA NA NA ND NA NA positive ND MW-45-42 NA NA NA NA NA NA NA NA positive NA MW-65-48 NA NA NA NA NA ND NA NA ND MW-45-61 NA NA NA NA NA NA NA NA positive NA MW-65-80 NA NA NA NA NA ND NA NA ND MW-46 NA NA NA NA NA NA NA NA positive NA MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-47-56 NA NA NA NA NA ND NA ND ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-47-80 NA NA NA NA NA ND NA ND ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND NA ND ND ND NA positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND NA ND ND ND NA positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-51-40 NA NA NA NA NA NA NA NA positive NA MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-79 NA NA NA NA NA NA NA NA positive NA MW-107 NA NA NA NA NA NA NA NA positive NA MW-51-104 NA NA NA NA NA NA NA NA positive NA MW-108 NA NA NA NA NA ND NA ND ND MW-51-135 NA NA NA NA NA NA NA NA positive NA MW-109 NA NA NA NA NA ND NA ND ND MW-51-163 NA NA NA NA NA NA NA NA positive NA MW-111 NA NA NA NA NA NA NA NA positive NA MW-51-189 NA NA NA NA NA NA NA NA positive NA U3-3 NA NA NA NA NA NA NA NA NA MW-52-11 NA NA NA NA NA NA NA NA positive NA U3-4D NA NA NA NA NA NA NA NA positive NA MW-52-18 NA NA NA NA NA NA NA NA positive NA U3-4S NA NA NA NA NA NA NA NA positive NA MW-52-48 NA NA NA NA NA NA NA NA positive NA U3-T1 NA NA NA NA NA NA NA NA positive NA MW-52-64 NA NA NA NA NA NA NA NA positive NA U3-T2 NA NA NA NA NA NA NA NA positive NA MW-52-122 NA NA NA NA NA NA NA NA positive NA U1-CSS ND NA NA NA ND ND NA NA positive ND MW-52-162 NA NA NA NA NA NA NA NA positive NA U1-NCD 2.31E+02 NA NA NA NA NA 1.14E+02 NA 1.73E+02 MW-52-181 NA NA NA NA NA NA NA NA positive NA U1-SFDS ND NA NA NA NA NA ND NA ND MW-53-82 NA NA ND NA ND NA ND NA positive ND I-2 NA NA NA NA NA NA NA NA positive NA MW-53-120 NA NA ND NA ND NA 1.45E+01 NA positive 1.45E+01 LAF-002 ND NA NA NA ND NA NA NA positive ND B-1 NA NA NA NA NA NA NA NA NA B-6 NA NA NA NA NA NA NA NA NA MH-5 VCFD NA NA NA NA NA NA NA NA NA Investigation Level Nickel Results (pCi/L)

3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.

Rolling Annual Average

1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.
2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
4) ** Indicates 2011 I.L. not computed for this well due to absence of 2010 data.

Well ID Nickel Results (pCi/L)

Investigation Level Rolling Annual Average Notes:

shaded value

G

^

XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XY XYXY XY XYXY XYXY XYXY XY XYXY XY XYXY XY XY XY XYXY XY XY XYXY XY XY XY XYXY XYXY XYXY XY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XY XY XY XYXY XYXY XY XY XYXY XYXY XYXY XY XY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XYXY XYXY XY XYXY XY XYXY XYXY XYXY XY XYXY X

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

? @

?

?

? @

?

?

?

?

?

?

?

?

?

?

?

?

?

?

?

Storage storage Gravel Gravel Storage No Access Grass Earth Parking Asphalt Asphalt curb Asphalt parking Asphalt Concrete curbs Concrete curb Concrete Concrete curb Wooden curb Grass A/C UNIT Handicap ramp A/C unit on concrete Stone curbs Asphalt drive Asphalt parking Asphalt parking Asphalt parking Asphalt parking Asphalt curb Shrubs Trans.

Transformer area and switch gear Storage Containers A/C Units Grass Concrete curb Grass Shrubs Open gr ate Tank Asphalt drive Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt Asphalt drive Asphalt Asphalt Drive Gravel Gravel Transformer yard Asphalt Drive this Area No Access Asphalt Conc rete Retaining Wa ll Stone retaining wall Gravel parking Gravel parking Gravel parking Gravel parking Stone curbs Stone curbs Asphalt parking Concrete curb Asphalt parking Concrete curb curb pad Asphalt curb Asphalt curb Asphalt parking Grass Asphalt curb Asphalt curb Grass Asphalt curb Asphalt parking Gravel parking Storage Storage Tank Fuel Oil Grass Asphalt drive Storage units Gravel Parking lot Asphalt Tank Overhead walkway Concrete curb Asphalt parking Asphalt parking Asphalt Asphalt Asphalt Asphalt Concrete pier Courtyard Asphalt Rip-rap 110 140 120 130 30 30 40 50 30 40 50 90 70 70 80 90 80 80 90 100 110 110 110 110 120 120 100 70 60 70 80 90 60 80 90 100 100 0

110 140 140 Transformer Gravel Storage Tank Fuel Oil Tank Tank Tank Covered Concrete Asphalt parking Condensate Tank Transformers on raised Concrete Pad Trans.

Transformers Concrete slab Tank Grass Transformers on raised Concrete Pad Tank Concrete Bridge Concrete Bridge Storage Tank Transformer Substation "H" Trailer Trans Tank Storage Tank Tank Pit Asphalt Trans Trans Trans Storage Tanks Asphalt Grass Vent pit Mach.

stand Unit 2 Condensate Storage Tank Liquid Nitrogen Transformers Yard (Gravel)

DISCHARGE OUTFALL CANAL Tank Gravel Shrubs Shrubs Shrubs Overhead Crane Grass FUEL TRAN SFE R PO O L STO RA GE PO O L STO RA GE PO O L FA IL ED FU EL AUX. PO O L DIS ASS EM B LY PO O L CAS K L O AD PO O L CAS K W AS H &

DIS ASS EM B LY ISO L ATIO N PI T PU MP SU CTI ON WELL WATER STO RA GE PO O L ROOF DRAIN ELEVATION 65' 43.8' 43.8' 43.8' 21.75' 22.75' (EL.=0.0) 33' 13' 43.8' 33' 33' 33' 33' 33' 42.5' 42.5' MH-4 MH-4A MH-5 MH-6 MH-2 B6 B6A B5 B4 B4A B3 B3A B2A B2 B1 A2 A1 U3-MH-14 F5 A2A CB-B CB-E CB-F C-1 C-3 D2 B7 B8 CB-33 CB-34 CB-15 CB-14 CB-13 CB-32 CB-31 CB-30 A7 U1-CB-22 U3-CB (U1-CB-10)

CB-29 U3-CB (U1-CB-9)

U1-CB-21 U1-CB-20 CB-28 CB-24 CB-27 E16 E16 E16A CB-6 CB-5A (CB-6)

CB-5B CB-7 CB-5 MH16 CB-3B CB3A CB4 CB-2C CB3 CB-2B CB-2A CB-2 CB-1 MH18 MH8 MH17 MH7 MH23A CB-16 MH9 MH10 MH11 MH22 MH21 MH13 MH3 MH12 MH1 CB-18 MH15 CB-19 CB-23 MH14 C2 E7 E6 E8 E9 E10 E11 E5 E5A E4 E4 E4A E3B E3 E3A F3 F4 CB E2 E2A F6 F7 E2B E2C E1 A6 A5 A3A A3 A4 E14 E15 E15A (U1-CB-8)

AB E13 E12 D1 CB-17 F2 F1 CB-12 MH-23 MH-19 MH-20 ROOF DRAIN Turbine Generator Building 2 Turbine Generator Building 1 Turbine Generator Building 3 Transformer Yard PAB Water Storage Tank FUEL POOL UNIT 2 1,015' 640' WEST FUEL POOL UNIT 1 UNIT 3 Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co Cs Ni Co UTILITY TUNNEL UTILITY TUNNEL CSS CSS TRENCH Cs Ni Co Cs Ni Co Cs Ni Co 50 40 30 20 10 5

50 40 30 20 5

20 13 10 Cs Ni Co B-1 Cs Ni Co B-6 ALL EYW AY U1-SFDS Cs Ni Co U1-NCD Cs Ni Co Cs Ni Co MH-5 VCFD 2

2 2

2 2

4 3

1 1

1 1

1 1

1 1

1 1

1 1

1 1

5 6

MW-68 I-2 HR-1 U3-3 U3-2 U3-1 RW-1 OUT-1 U3-C1 U2-C1 MW-67 MW-66 MW-37 MW-36 MW-35 MW-34 MW-33 U3-4S U3-4D MW-52 MW-51 MW-50 MW-49 MW-47 MW-46 MW-45 MW-44 MW-42 MW-41 MW-38 MW-32 MW-31 MW-40 MW-48 MW-43 MW-39 U3-T2 U3-T1 MW-65 MW-62 MW-60 MW-59 MW-58 MW-57 MW-56 MW-55 MW-54 MW-53 MW-30 MW-64 MW-61 MW-63 U1-CSS MW-105 MW-101 MW-110 MW-111 MW-112 MW-109 MW-108 MW-107 H U D S O N R I V E R ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 6140 9.23 64.6 34.8 9.13 44.8 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 34 0.1 8.3 7.2 7.05 9.77

-1.3 4.68 5.16 6.14 6.02 8.44 3.69 3.76 9.02 0.81 8.94 2.69 3.81 7.88 1.22 33.9 22.7 21.9 10.6 3.13 3.29 6.97 4.06 5.76 6.41 7.45 9.05 8.82 9.02 9.92 2.34 7.06 6.46 7.19 5.55 6.04 5.64 0.49 0.68 0.47 2.52 0.47 0.16 2.04 45.79 39.64 11.53 12.16 44.48 12.81 35.07 34.43 41.21 44.13 50.75

-1.64

-0.15

-0.48 29.36 37.68 36.03 40.36 49.24 40.66 43.87 44.32 46.83 52.35 54.22 32.72 23.79 24.43 24.79 25.12 25.21 26.96 30.71 31.76 32.15 25.45 26.68 21.08 22.37 25.16 29.05 10.48 10.54 10.68 12.36 11.71 10.27

-1.19

-1.54

-0.86

-2.26

-0.98

-1.24

-0.13

-0.08

-1.79

-1.69

-1.85

-0.37

-0.85

-1.24

-0.84

-0.15

-0.12

-1.93

-0.14

-0.86

-0.82

-0.02

-1.56

-1.02

-2.59

-2.25

-0.91

-2.03 115.76 DRY ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 20.6 ND ND ND ND ND ND ND 19.03 18307.5 ND ND ND ND ND ND ND ND 9.45 0.29 21.51 ND ND ND ND ND 14.5 148.67 207.425 Plant North N

N 50 0

50 100 150 25 Feet Figure No.:

Job No.:

Dwg. Date:

Proj. Mgr.: MJB Designed By: MJB Reviewed By: MJB Operator: GAS 01.0017869.92 8-Q4 INDIAN POINT ENERGY CENTER BUCHANAN, NEW YORK GZA GeoEnvironmental, Inc.

One Edgewater Drive Norwood, MA 02062 Phone: (781) 278-3700 Fax: (781) 278-5701 4th QUARTER 2011 ROLLING AVERAGE CESIUM, COBALT, AND NICKEL ACTIVITY MAP 1

4th QUARTER 2011 ROLLING AVERAGE CESIUM, COBALT, AND NICKEL ACTIVITY MAP 1

East Fuel Pool LEGEND Cesium Data1 Average Cs, pCi/L Cobalt Data1 Average Co, pCi/L Nickel Data 1 Average Ni, pCi/L Not Detected (ND)

ND - 10 10 - 50 50 - 500 500 - 1,000 1,000 - 5,000

> 5,000 No Depth-Specific Samples ND 4.2 37 294 836 4460 6000 Not Detected (ND)

ND - 25 25 - 100 100 - 200 200 - 300 300 - 500

> 500 No Depth-Specific Samples ND 4

83 194 250 350 508 Not Detected (ND)

ND - 12 12 - 25 25 - 50 50 - 100 100 - 250 250 - 500

> 500 No Depth-Specific Samples ND 4

20 49 54 207 300 526 Groundwater Elevation Contours Depth-Specific Data Probable Legacy Release SSCs MW-30 Boring / Monitoring Installation Designation Longterm Radionuclide Monitoring Installation

?

Standby Radionuclide Monitoring Installation

?

Unit 1 West Fuel Pool (All U1-SFPs drained and inactive as of October 2008)

Unit 2 Fuel Pool (All identified leaks repaired as of December 2007)

Containment Spray Sump Trench Terminated Connection To Storm Drain Drain Exfiltration Inter-Structure Joint / Mud Mat Contours Other Than 10' Interval 20 5

11.3 11.9 12.6 12.8 Screened in Soil Screened in Bedrock Multiple Screened Intervals w/ Depth 6000 836 294 Average activity of Cs 137 (pCi/L) for each screened interval.

37 508 250 194 4

526 207 49 20 Average activity of Co 60 (pCi/L) for each screened interval.

Average activity of Ni 63 (pCi/L) for each screened interval.

3 Transient Distillate Tank Valve Leak in Unit 1 Fuel Storage Building - 3/07/2009 G

4 Footing Drain Active Storm Drain Catch Basin Abandoned Storm Drain Ambient "Watertable" Contours for Q4 2008 (11/11/2008) 1 1

Groundwater elevation for each screened interval at time of low river tide for Q4 2008 (11/11/2008).

1 1

^

Transient Spill from Temporary R.O. Skid Piping -

Entered MW-32 Vault and MH 11/21/2009 5

Notes:

1. Groundwater contours drawn from Q4 2008 groundwater data to show groundwater conditions used for recalibration of the Precipitation Mass Balance Model (see Q2 2009 LTM Report). These contours developed from limited data recorded on 11/11/2008. Actual elevations may vary from conditions shown and the actual distribution of piezometric heads is likely more complex than indicated.

Data Notes:

1. Average Cesium, Cobalt, and Nickel activity values are yearly rolling arithmetic averages of the current and preceeding three quarters' data.

Only values greater than the MDC are used in this average, thus adding a degree of conservatism to the subsequent dose computations.

2. Storm or foundation drain sampling locations, for which investigation levels are not applicable.
3. Historically elevated Tritium levels in MW-42-49 obsrved during Q1 2009 were consistent with leakage visually identified on 03/07/2009 (and terminated immediately thereafter) from the waste distillate tank valves located within the Unit 1 fuel storage building. Elevated tritium levels not seen in MW-53; therefore, this transient leakage was likely to have been generally confined to, and contained by, the Unit 1 North Curtain Drain.
4. Historically elevated Tritium levels in MW-45-42 observed during Q2 2009 were consistent with an increased activity observed in Unit 3 Manhole A2. This release was initially detected in a storm drain sample collected 03/25/2009 under the 80-10 Effluents Program. This Tritium peak dissipated prior to samples taken during the subsequent quarter. Additionally, transient Tritium peaks have been recently detected in MH-A2 from Q3 2010 to Q3 2011. These increases are consistent with elevated Tritium levels in MW-41-40, MW-46 and B-1. Based on investigations initiated in, and ongoing since, 2009 and the more recent sampling of the Unit 3 Fuel Storage Building (FSB) roof drains, it has been concluded that these increases in storm drain and monitoring well Tritium activity are due to condensation of SFP evaporation on the FSB roof (Washout) when the exhaust fan is not operating, which then enters the roof drains and discharges directly into MH-A2 during rainfall events. As such, Entergy placed the FSB vent fan back in service on 7-21-2011 and the Tritium activity in MH-A2 returned to baseline conditions within 2 weeks.
5. Elevated levels of Tritium detected in MH-9 and MH-10a during routine 80-10 Effluents Program sampling on 1/15/2010 appears to have originated from a November 21, 2009 transient leak in temporary RWST / R.O. skid connection hoses, which flowed into MH-9. It also appears that this release entered the well vault for MW-32, and may have penetrated the well casings and entered the subsurface around the monitoring installation.
6. Elevated levels of Tritium initially detected in U1-CSS, MW-39, MW-46, MW-54, MW-56 and MW-57 during the Q2-2011 sampling event appear to have originated from a Q2 2011 sample sink overflow and subsequent floor flooding in a Unit 1 Chemical Systems Building sample room on the 53 elevation.

General Notes:

1. Base map was developed from an untitled electronic file provided by Badey and Watson Surveying and Engineering, P.C., Dated 2/3/06; CAD file name : "GZA.dwg".

© 2012 - GZA GeoEnvironmental, Inc. \\\\gzanor\\Jobs\\17,000-18,999\\17869\\17869-91.MG\\Figures\\GIS\\MXD Documents\\2011-comb\\12-08-30 F08 Q4 2011 Rolling Average Cesium, Cobalt, and Nickel Activity Map 17869-92_final.mxd, 9/18/2012, 8:26:47 AM, jennifer.pisani 09-18-2012 Sample Sink Overflow - Unit 1 Chemical Systems Building Q2 2011 6

Unit 3 SFP Evap. Washout to MH-A2 - 3/25/09 XX X X

Localized Transient Releases (Surface Spills and Washout)

(initial)

Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1

Quarter 2 Post Quarter 2

Quarter 3 Post Quarter 3

Quarter 4 Post Quarter 4 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 MW-30-69 ND ND ND ND ND NA ND NA positive ND MW-54-37 ND NA ND ND ND NA ND NA positive ND MW-30-84 ND ND ND ND ND NA ND NA positive ND MW-54-58 ND NA ND ND ND NA ND NA positive ND MW-31-49 ND ND ND NA ND NA ND NA positive ND MW-54-123 ND NA ND ND ND NA ND NA positive ND MW-31-63 ND ND ND NA ND NA ND NA positive ND MW-54-144 ND NA ND ND ND NA ND NA positive ND MW-31-85 ND ND ND NA ND NA ND NA positive ND MW-54-173 ND NA ND ND ND NA ND NA positive ND MW-32-48 NA NA NA NA NA NA NA NA positive NA MW-54-190 ND NA ND ND ND NA ND NA positive ND MW-32-59 ND ND ND NA ND NA ND NA positive ND MW-55-24 ND NA NA NA ND NA ND NA positive ND MW-32-85 ND ND ND NA ND NA ND NA positive ND MW-55-35 ND NA NA NA ND NA ND NA positive ND MW-32-149 ND ND ND NA ND NA ND NA positive ND MW-55-54 ND NA NA NA ND NA ND NA positive ND MW-32-173 ND ND ND NA ND NA ND NA positive ND MW-56-53 NA NA ND ND NA ND ND NA positive ND MW-32-190 ND ND ND NA ND NA ND NA positive ND MW-56-83 NA NA ND ND NA ND ND NA positive ND MW-33 NA NA NA NA NA NA NA NA positive NA MW-57-11 NA NA ND ND NA ND NA NA positive ND MW-35 NA NA NA NA NA NA NA NA positive NA MW-57-20 NA NA ND ND NA ND NA NA positive ND MW-36-24 ND NA ND NA ND NA ND NA positive ND MW-57-45 NA NA ND ND NA ND NA NA positive ND MW-36-41 ND NA ND NA ND NA ND NA positive ND MW-58-26 NA NA ND ND NA ND ND NA positive ND MW-36-52 ND NA ND NA ND NA ND NA positive ND MW-58-65 NA NA ND ND NA ND ND NA positive ND MW-37-22 ND NA ND NA ND NA ND NA positive ND MW-59-32 NA NA NA ND NA ND NA NA ND MW-37-32 ND NA ND NA ND NA ND NA positive ND MW-59-45 NA NA NA ND NA ND NA NA ND MW-37-40 ND NA ND NA ND NA ND NA positive ND MW-59-68 NA NA NA ND NA ND NA NA ND MW-37-57 ND NA ND NA ND NA ND NA positive ND MW-60-35 ND NA ND NA ND NA ND NA positive ND MW-39-67 NA NA ND ND NA ND ND NA positive ND MW-60-53 ND NA ND NA ND NA ND NA positive ND MW-39-84 NA NA ND ND NA ND ND NA positive ND MW-60-72 ND NA ND NA ND NA ND NA positive ND MW-39-102 NA NA 4.48E+01 ND NA ND ND NA positive 4.48E+01 MW-60-135 ND NA ND NA ND NA ND NA positive ND MW-39-124 NA NA 9.13E+00 ND NA ND ND NA positive 9.13E+00 MW-60-154 ND NA ND NA ND NA ND NA positive ND MW-39-183 NA NA ND ND NA ND ND NA positive ND MW-60-176 ND NA ND NA ND NA ND NA positive ND MW-39-195 NA NA ND ND NA ND ND NA positive ND MW-62-18 ND NA ND ND ND NA ND NA positive ND MW-40-27 ND NA ND NA NA NA ND NA positive ND MW-62-37 ND NA ND ND ND NA ND NA positive ND MW-40-46 ND NA ND NA NA NA ND NA positive ND MW-62-53 ND NA ND ND ND NA ND NA positive ND MW-40-81 ND NA ND NA NA NA ND NA positive ND MW-62-71 ND NA ND ND ND NA ND NA positive ND MW-40-100 2.46E+01***

NA ND NA NA NA ND NA positive ND MW-62-92 ND NA ND ND ND NA ND NA positive ND MW-40-127 5.07E+01***

NA ND NA NA NA ND NA positive ND MW-62-138 ND NA ND ND ND NA ND NA positive ND MW-40-162 ND NA ND NA NA NA ND NA positive ND MW-62-182 ND NA ND ND ND NA ND NA positive ND MW-41-40 ND NA ND ND ND NA ND NA positive ND MW-63-18 ND NA ND ND ND NA ND NA positive ND MW-41-63 ND NA ND ND ND NA ND NA positive ND MW-63-34 ND NA ND ND ND NA ND NA positive ND MW-42-49 3.30E+04 NA 2.15E+04 NA 1.57E+04 NA 3.03E+03 NA 6.58E+04 1.83E+04 MW-63-50 ND NA ND ND ND NA ND NA positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-93 ND NA ND ND ND NA ND NA positive ND MW-43-28 ND NA ND NA ND NA ND NA positive ND MW-63-112 ND NA ND ND ND NA ND NA positive ND MW-43-62 ND NA ND NA ND NA ND NA positive ND MW-63-121 ND NA ND ND ND NA ND NA positive ND MW-44-66 ND NA ND ND ND NA ND NA positive ND MW-63-163 ND NA ND ND ND NA ND NA positive ND MW-44-102 ND NA ND ND ND NA ND NA positive ND MW-63-174 ND NA ND ND ND NA ND NA positive ND MW-45-42 ND NA ND ND NA ND ND NA positive ND MW-65-48 NA NA NA ND NA NA NA NA ND MW-45-61 ND NA ND ND NA ND ND NA positive ND MW-65-80 NA NA NA ND NA NA NA NA ND MW-46 ND NA ND ND ND NA ND NA positive ND MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-47-56 NA NA NA ND NA ND ND NA ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-47-80 NA NA NA ND NA ND ND NA ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND ND ND NA ND NA positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND ND ND NA ND NA positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-51-40 ND NA ND NA ND NA ND NA positive ND MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-79 ND NA ND NA ND NA ND NA positive ND MW-107 NA NA ND NA NA NA NA NA positive ND MW-51-104 ND NA ND NA ND NA ND NA positive ND MW-108 NA NA NA ND NA ND NA NA ND MW-51-135 ND NA ND NA ND NA ND NA positive ND MW-109 NA NA NA ND NA ND NA NA ND MW-51-163 ND NA ND NA ND NA ND NA positive ND MW-111 NA NA NA NA NA NA ND NA 1.36E+01 ND MW-51-189 3.77E+01***

NA ND NA ND NA ND NA positive ND U3-3 NA NA NA ND NA ND NA NA ND MW-52-11 NA NA ND ND NA NA NA NA positive ND U3-4D ND NA ND ND ND NA ND NA positive ND MW-52-18 NA NA ND ND NA NA NA NA positive ND U3-4S NA NA ND ND ND NA ND NA positive ND MW-52-48 NA NA ND ND NA NA NA NA positive ND U3-T1 ND NA ND NA ND NA ND NA positive ND MW-52-64 NA NA ND ND NA NA NA NA positive ND U3-T2 ND NA ND ND ND NA ND NA positive ND MW-52-122 NA NA 3.48E+01 ND NA NA NA NA positive 3.48E+01 U1-CSS NA NA ND ND NA NA ND NA positive ND MW-52-162 NA NA ND ND NA NA NA NA positive ND U1-NCD NA NA NA NA 4.77E+03 NA 5.92E+03_7.73E+03 NA 6.14E+03 MW-52-181 NA NA 6.46E+01 ND NA NA NA NA positive 6.46E+01 U1-SFDS NA NA NA NA 9.23E+00 NA ND_ND NA 9.23E+00 MW-53-82 ND NA ND NA ND NA ND NA positive ND I-2 NA NA NA NA ND NA ND NA positive ND MW-53-120 ND NA ND NA ND NA ND NA positive ND LAF-002 NA NA ND NA NA NA ND NA positive ND B-1 2.15E+01 NA 2.05E+01 NA 1.51E+01 NA NA NA 1.90E+01 B-6 ND NA ND ND ND NA ND NA ND MH-5 VCFD ND NA ND ND****

ND_ND_ND ND_ND ND_ND NA ND Well ID Cesium Results (pCi/L)

Investigation Level Rolling Annual Average Notes:

6) **** Four Post-Q2 2011 MH-5 VCFD samples were collected. All four samples were ND for Cs-137.
2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.
4) ** Indicates 2011 I.L. not computed for this well due to absence of 2010 data.

Cesium Results (pCi/L)

Rolling Annual Average Well ID

1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.

Investigation Level

5) *** The Q1 2011 MW-40-100, MW-40-127 and MW-51-189 Cs-137 results were verified by re-analysis. However, based on the available chemistry and Site hydrogeologic data, these values do not appear to be representative of the groundwater conditions at these sampling intervals.

shaded value Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 MW-30-69 ND ND ND ND ND NA ND NA positive ND MW-54-37 ND NA ND ND ND NA ND NA positive ND MW-30-84 ND ND ND ND ND NA ND NA positive ND MW-54-58 ND NA ND ND ND NA ND NA positive ND MW-31-49 ND ND ND NA ND NA ND NA positive ND MW-54-123 ND NA ND ND ND NA ND NA positive ND MW-31-63 ND ND ND NA ND NA ND NA positive ND MW-54-144 ND NA ND ND ND NA ND NA positive ND MW-31-85 ND ND ND NA ND NA ND NA positive ND MW-54-173 ND NA ND ND ND NA ND NA positive ND MW-32-48 NA NA NA NA NA NA NA NA positive NA MW-54-190 ND NA ND ND ND NA ND NA positive ND MW-32-59 ND ND ND NA ND NA ND NA positive ND MW-55-24 ND NA NA NA ND NA ND NA positive ND MW-32-85 ND ND ND NA ND NA ND NA positive ND MW-55-35 ND NA NA NA ND NA ND NA positive ND MW-32-149 ND ND ND NA ND NA ND NA positive ND MW-55-54 ND NA NA NA ND NA ND NA positive ND MW-32-173 ND ND ND NA ND NA ND NA positive ND MW-56-53 ND NA ND ND NA ND ND NA positive ND MW-32-190 ND ND ND NA ND NA ND NA positive ND MW-56-83 ND NA ND ND NA ND ND NA positive ND MW-33 NA NA NA NA NA NA NA NA positive NA MW-57-11 ND NA ND ND NA ND NA NA positive ND MW-35 NA NA NA NA NA NA NA NA positive NA MW-57-20 ND NA ND ND NA ND NA NA positive ND MW-36-24 ND NA ND NA ND NA ND NA positive ND MW-57-45 ND NA ND ND NA ND NA NA positive ND MW-36-41 ND NA ND NA ND NA ND NA positive ND MW-58-26 ND NA ND ND NA ND ND NA positive ND MW-36-52 ND NA ND NA ND NA ND NA positive ND MW-58-65 ND NA ND ND NA ND ND NA positive ND MW-37-22 ND NA ND NA ND NA ND NA positive ND MW-59-32 NA NA NA ND NA ND NA NA ND MW-37-32 ND NA ND NA ND NA ND NA positive ND MW-59-45 NA NA NA ND NA ND NA NA ND MW-37-40 ND NA ND NA ND NA ND NA positive ND MW-59-68 NA NA NA ND NA ND NA NA ND MW-37-57 ND NA ND NA ND NA ND NA positive ND MW-60-35 ND NA ND NA ND NA ND NA positive ND MW-39-67 ND NA ND ND NA ND ND NA positive ND MW-60-53 ND NA ND NA ND NA ND NA positive ND MW-39-84 ND NA ND ND NA ND ND NA positive ND MW-60-72 ND NA ND NA ND NA ND NA positive ND MW-39-102 ND NA ND ND NA ND ND NA positive ND MW-60-135 ND NA ND NA ND NA ND NA positive ND MW-39-124 ND NA ND ND NA ND ND NA positive ND MW-60-154 ND NA ND NA ND NA ND NA positive ND MW-39-183 ND NA ND ND NA ND ND NA positive ND MW-60-176 ND NA ND ND ND NA ND NA positive ND MW-39-195 ND NA ND ND NA ND ND NA positive ND MW-62-18 ND NA ND ND ND NA ND NA positive ND MW-40-27 ND NA ND NA NA NA ND NA positive ND MW-62-37 ND NA ND ND ND NA ND NA positive ND MW-40-46 ND NA ND NA NA NA ND NA positive ND MW-62-53 ND NA ND ND ND NA ND NA positive ND MW-40-81 ND NA ND NA NA NA ND NA positive ND MW-62-71 ND NA ND ND ND NA ND NA positive ND MW-40-100 ND NA ND NA NA NA ND NA positive ND MW-62-92 ND NA ND ND ND NA ND NA positive ND MW-40-127 ND NA ND NA NA NA ND NA positive ND MW-62-138 ND NA ND ND ND NA ND NA positive ND MW-40-162 ND NA ND NA NA NA ND NA positive ND MW-62-182 ND NA ND ND ND NA ND NA positive ND MW-41-40 ND NA ND ND ND NA ND NA positive ND MW-63-18 ND NA ND ND ND NA ND NA positive ND MW-41-63 ND NA ND ND ND NA ND NA positive ND MW-63-34 ND NA ND ND ND NA ND NA positive ND MW-42-49 ND NA ND NA ND NA ND NA positive ND MW-63-50 ND NA ND ND ND NA ND NA positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-93 ND NA ND ND ND NA ND NA positive ND MW-43-28 ND NA ND NA ND NA ND NA positive ND MW-63-112 ND NA ND ND ND NA ND NA positive ND MW-43-62 ND NA ND NA ND NA ND NA positive ND MW-63-121 ND NA ND ND ND NA ND NA positive ND MW-44-66 ND NA ND ND ND NA ND NA positive ND MW-63-163 ND NA ND ND ND NA ND NA positive ND MW-44-102 ND NA ND ND ND NA ND NA positive ND MW-63-174 ND NA ND ND ND NA ND NA positive ND MW-45-42 ND NA ND ND NA ND ND NA positive ND MW-65-48 NA NA NA ND NA NA NA NA ND MW-45-61 ND NA ND ND NA ND ND NA positive ND MW-65-80 NA NA NA ND NA NA NA NA ND MW-46 ND NA ND ND ND NA ND NA positive ND MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-47-56 NA NA NA ND NA ND ND NA ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-47-80 NA NA NA ND NA ND ND NA ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND ND ND NA ND NA positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND ND ND NA ND NA positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-51-40 ND NA ND NA ND NA ND NA positive ND MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-79 ND NA ND NA ND NA ND NA positive ND MW-107 ND NA ND NA NA NA NA NA positive ND MW-51-104 ND NA ND NA ND NA ND NA positive ND MW-108 NA NA NA ND NA ND NA NA ND MW-51-135 ND NA ND NA ND NA ND NA positive ND MW-109 NA NA NA ND NA ND NA NA ND MW-51-163 ND NA ND NA ND NA ND NA positive ND MW-111 ND NA NA ND NA NA ND NA positive ND MW-51-189 ND NA ND NA ND NA ND NA positive ND U3-3 NA NA NA ND NA ND NA NA ND MW-52-11 ND NA ND ND NA NA NA NA positive ND U3-4D ND NA ND ND ND NA ND NA positive ND MW-52-18 ND NA ND ND NA NA NA NA positive ND U3-4S ND NA ND ND ND NA ND NA positive ND MW-52-48 ND NA ND ND NA NA NA NA positive ND U3-T1 ND NA ND NA ND NA ND NA positive ND MW-52-64 ND NA ND ND NA NA NA NA positive ND U3-T2 ND NA ND ND ND NA ND NA positive ND MW-52-122 ND NA ND ND NA NA NA NA positive ND U1-CSS ND NA ND ND NA NA ND NA positive ND MW-52-162 ND NA ND ND NA NA NA NA positive ND U1-NCD ND NA NA NA ND NA ND_ND NA ND MW-52-181 ND NA ND ND NA NA NA NA positive ND U1-SFDS ND NA NA NA ND NA ND_ND NA ND MW-53-82 ND NA ND NA ND NA ND NA positive ND I-2 ND NA NA NA ND NA ND NA positive ND MW-53-120 ND NA ND NA ND NA ND NA positive ND LAF-002 ND NA ND NA NA NA ND NA positive ND B-1 ND NA ND NA ND NA NA NA ND B-6 ND NA ND ND ND NA ND NA ND MH-5 VCFD ND NA ND ND***

ND_ND_ND ND_ND ND_ND NA ND Investigation Level Cobalt Results (pCi/L)

Rolling Annual Average

1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.

Well ID Cobalt Results (pCi/L)

Investigation Level Rolling Annual Average Notes:

6) *** Four Post-Q2 2011 MH-5 VCFD samples were collected. All four samples were ND for Co-60.
2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.
4) ** Indicates 2011 I.L. not computed for this well due to absence of 2010 data.

Well ID shaded value Well ID Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 Quarter 1 Post Quarter 1 Quarter 2 Post Quarter 2 Quarter 3 Post Quarter 3 Quarter 4 Post Quarter 4 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 2011 MW-30-69 NA NA NA NA NA NA NA NA positive NA MW-54-37 ND NA ND ND ND NA ND NA positive ND MW-30-84 NA NA NA NA NA NA NA NA positive NA MW-54-58 ND NA ND ND ND NA ND NA positive ND MW-31-49 NA NA NA NA NA NA NA NA positive NA MW-54-123 ND NA ND ND ND NA ND NA positive ND MW-31-63 NA NA NA NA NA NA NA NA positive NA MW-54-144 ND NA ND ND ND NA ND NA positive ND MW-31-85 NA NA NA NA NA NA NA NA positive NA MW-54-173 ND NA ND ND ND NA ND NA positive ND MW-32-48 NA NA NA NA NA NA NA NA positive NA MW-54-190 ND NA ND ND ND NA ND NA positive ND MW-32-59 NA NA NA NA NA NA NA NA positive NA MW-55-24 ND NA NA NA ND NA ND NA positive ND MW-32-85 NA NA NA NA NA NA NA NA positive NA MW-55-35 ND NA NA NA ND NA ND NA positive ND MW-32-149 NA NA NA NA NA NA NA NA positive NA MW-55-54 ND NA NA NA ND NA ND NA positive ND MW-32-173 NA NA NA NA NA NA NA NA positive NA MW-56-53 NA NA NA ND NA NA ND NA positive ND MW-32-190 NA NA NA NA NA NA NA NA positive NA MW-56-83 NA NA NA ND NA NA ND NA positive ND MW-33 NA NA NA NA NA NA NA NA positive NA MW-57-11 NA NA ND ND NA ND NA NA positive ND MW-35 NA NA NA NA NA NA NA NA positive NA MW-57-20 NA NA ND ND NA ND NA NA positive ND MW-36-24 NA NA NA NA NA NA NA NA positive NA MW-57-45 NA NA ND ND NA ND NA NA positive ND MW-36-41 NA NA NA NA NA NA NA NA positive NA MW-58-26 NA NA NA ND NA NA NA NA positive ND MW-36-52 NA NA NA NA NA NA NA NA positive NA MW-58-65 NA NA NA ND NA NA NA NA positive ND MW-37-22 NA NA NA NA NA NA NA NA positive NA MW-59-32 NA NA NA ND NA ND NA NA ND MW-37-32 NA NA NA NA NA NA NA NA positive NA MW-59-45 NA NA NA ND NA ND NA NA ND MW-37-40 NA NA NA NA NA NA NA NA positive NA MW-59-68 NA NA NA ND NA ND NA NA ND MW-37-57 NA NA NA NA NA NA NA NA positive NA MW-60-35 ND NA ND NA NA NA NA NA positive ND MW-39-67 NA NA NA NA NA NA NA NA positive NA MW-60-53 ND NA ND NA NA NA NA NA positive ND MW-39-84 NA NA NA NA NA NA NA NA positive NA MW-60-72 ND NA ND NA NA NA NA NA positive ND MW-39-102 NA NA NA NA NA NA NA NA positive NA MW-60-135 ND NA ND NA NA NA NA NA positive ND MW-39-124 NA NA NA NA NA NA NA NA positive NA MW-60-154 ND NA ND NA NA NA NA NA positive ND MW-39-183 NA NA NA NA NA NA NA NA positive NA MW-60-176 ND NA ND NA NA NA NA NA positive ND MW-39-195 NA NA NA NA NA NA NA NA positive NA MW-62-18 NA NA NA ND NA NA NA NA positive ND MW-40-27 NA NA NA NA NA NA NA NA positive NA MW-62-37 NA NA NA ND NA NA NA NA positive ND MW-40-46 NA NA NA NA NA NA NA NA positive NA MW-62-53 NA NA NA ND NA NA NA NA positive ND MW-40-81 NA NA NA NA NA NA NA NA positive NA MW-62-71 NA NA NA ND NA NA NA NA positive ND MW-40-100 NA NA NA NA NA NA NA NA positive NA MW-62-92 NA NA NA ND NA NA NA NA positive ND MW-40-127 NA NA NA NA NA NA NA NA positive NA MW-62-138 NA NA NA ND NA NA NA NA positive ND MW-40-162 NA NA NA NA NA NA NA NA positive NA MW-62-182 NA NA NA ND NA NA NA NA positive ND MW-41-40 NA NA NA NA NA NA NA NA positive NA MW-63-18 NA NA NA ND NA NA NA NA positive ND MW-41-63 NA NA NA NA NA NA NA NA positive NA MW-63-34 NA NA NA ND NA NA NA NA positive ND MW-42-49 3.02E+02 NA 1.90E+02 NA 2.80E+02 NA 5.77E+01 NA 6.74E+02 2.07E+02 MW-63-50 NA NA NA ND NA NA NA NA positive ND MW-42-78 ND NA ND NA ND NA ND NA positive ND MW-63-93 NA NA NA ND NA NA NA NA positive ND MW-43-28 NA NA NA NA NA NA NA NA positive NA MW-63-112 NA NA NA ND NA NA NA NA positive ND MW-43-62 NA NA NA NA NA NA NA NA positive NA MW-63-121 NA NA NA ND NA NA NA NA positive ND MW-44-66 NA NA NA NA NA NA NA NA positive NA MW-63-163 NA NA NA ND NA NA NA NA positive ND MW-44-102 NA NA NA NA NA NA NA NA positive NA MW-63-174 NA NA NA ND NA NA NA NA positive ND MW-45-42 NA NA NA NA NA NA NA NA positive NA MW-65-48 NA NA NA ND NA NA NA NA ND MW-45-61 NA NA NA NA NA NA NA NA positive NA MW-65-80 NA NA NA ND NA NA NA NA ND MW-46 NA NA NA NA NA NA NA NA positive NA MW-66-21 ND NA ND NA ND NA ND NA positive ND MW-47-56 NA NA NA ND NA ND ND NA ND MW-66-36 ND NA ND NA ND NA ND NA positive ND MW-47-80 NA NA NA ND NA ND ND NA ND MW-67-39 ND NA ND NA ND NA ND NA positive ND MW-49-26 ND NA ND NA ND NA ND NA positive ND MW-67-105 ND NA ND NA ND NA ND NA positive ND MW-49-42 ND NA ND NA ND NA ND NA positive ND MW-67-173 ND NA ND NA ND NA ND NA positive ND MW-49-65 ND NA ND NA ND NA ND NA positive ND MW-67-219 ND NA ND NA ND NA ND NA positive ND MW-50-42 ND NA ND ND ND NA ND NA positive ND MW-67-276 ND NA ND NA ND NA ND NA positive ND MW-50-66 ND NA ND ND ND NA ND NA positive ND MW-67-323 ND NA ND NA ND NA ND NA positive ND MW-51-40 NA NA NA NA NA NA NA NA positive NA MW-67-340 ND NA ND NA ND NA ND NA positive ND MW-51-79 NA NA NA NA NA NA NA NA positive NA MW-107 NA NA NA NA NA NA NA NA positive NA MW-51-104 NA NA NA NA NA NA NA NA positive NA MW-108 NA NA NA ND NA ND NA NA ND MW-51-135 NA NA NA NA NA NA NA NA positive NA MW-109 NA NA NA ND NA ND NA NA ND MW-51-163 NA NA NA NA NA NA NA NA positive NA MW-111 NA NA NA NA NA NA NA NA positive NA MW-51-189 NA NA NA NA NA NA NA NA positive NA U3-3 NA NA NA NA NA NA NA NA NA MW-52-11 NA NA NA NA NA NA NA NA positive NA U3-4D NA NA NA NA NA NA NA NA positive NA MW-52-18 NA NA NA NA NA NA NA NA positive NA U3-4S NA NA NA NA NA NA NA NA positive NA MW-52-48 NA NA NA NA NA NA NA NA positive NA U3-T1 NA NA NA NA NA NA NA NA positive NA MW-52-64 NA NA NA NA NA NA NA NA positive NA U3-T2 NA NA NA NA NA NA NA NA positive NA MW-52-122 NA NA NA NA NA NA NA NA positive NA U1-CSS NA NA ND ND NA NA ND NA positive ND MW-52-162 NA NA NA NA NA NA NA NA positive NA U1-NCD NA NA NA NA 1.14E+02 NA 1.36E+02_1.96E+02 NA 1.49E+02 MW-52-181 NA NA NA NA NA NA NA NA positive NA U1-SFDS NA NA NA NA ND NA 2.06E+01_ND NA 2.06E+01 MW-53-82 ND NA ND NA ND NA ND NA positive ND I-2 NA NA NA NA NA NA NA NA positive NA MW-53-120 ND NA ND NA 1.45E+01 NA ND NA positive 1.45E+01 LAF-002 NA NA ND NA NA NA ND NA positive ND B-1 NA NA NA NA NA NA NA NA NA B-6 NA NA NA NA NA NA NA NA NA MH-5 VCFD NA NA NA NA NA NA NA NA NA Investigation Level Nickel Results (pCi/L)

3)
  • Indicates storm or foundation drain sampling locations, for which investigation levels are not applicable.

Rolling Annual Average

1) Only results greater than the MDC are reported herein. ND therefore indicates that the analytical result was below the MDC and typically also below the standard deviation threshold of three times 1 sigma. The rolling average is calculated using only results greater than the MDC. Given that ND represents real groundwater sampling results where the radionuclide activity level is either positive but very low and unquantifiable, or not detectable above background, its exclusion results in a high bias to the average and thus adds a measure of conservatism to the subsequent dose computations.
2) A shaded value indicates that the reported activity exceeds the Investigation Level (I.L.) that was applicable at the time of sampling. NA indicates that data is not available for this time period.
4) ** Indicates 2011 I.L. not computed for this well due to absence of 2010 data.

Well ID Nickel Results (pCi/L)

Investigation Level Rolling Annual Average Notes:

shaded value

FINAL QUARTERLY LONG-TERM GROUNDWATER MONITORING REPORT Q1 THROUGH Q4 2011 (REPORT NO. 13)

APPENDIX A: LIMITATIONS

HYDROGEOLOGICAL LIMITATIONS

1.

The conclusions and recommendations submitted in this report are based in part upon the radiological, chemical and physical data from water analyses. These data were obtained from specific sampling locations at specific times. The full nature and extent of variations in the data between these specific locations and times are not known. The conditions existing between these specific locations and times have only been inferred using interpolation and extrapolation based on judgment.

2.

The subsurface profiles described in the text and presented in the report figures are intended to convey anticipated trends in subsurface conditions. The conditions shown are approximate and generalized and were developed, in part, based on judgment. For specific information at specific locations, refer to the individual subsurface investigation logs.

3.

Water level readings (piezometric pressures) have been made in the specific borings, monitoring wells, and Waterloo installations at times and under conditions stated. These data have been reviewed and interpretations have been made in the text and on the figures of this report. However, it must be noted that temporal and spatial fluctuations in the level of the groundwater may occur due to variations in rainfall and other factors different from those prevailing at the time and location measurements were made.

4.

Where quantitative laboratory testing has been conducted by an outside laboratory, GZA has relied upon the validity of the data provided, and has not conducted an independent laboratory evaluation of the reliability of these data.

5.

Radiological and chemical analyses have been performed for specific parameters during the course of this study, as summarized in the text. Additional constituents not searched for may be present in soil and groundwater at the site.

6.

Variations in the types and concentrations of contaminants and variations in their flow paths may occur due to seasonal water table fluctuations, past and current plant operational practices, the passage of time, and other factors. Should additional data (water analyses, water elevations, subsurface deposits, plant construction and operation, etc.) become available in the future, these data should be reviewed by GZA, and the conclusions and recommendations presented herein modified accordingly.

7.

This monitoring report was developed by GZA GeoEnvironmental Inc for the exclusive of Entergy Nuclear Northeast (Entergy) at the Indian Point Energy Center. Any use of data or information provided in the report, by parties other than Entergy, is prohibitated without the prior written permission of Entergy and GZA.

J:\\17,000-18,999\\17869\\161619-00.MG\\WORK\\LTM_Report\\TABLES and APPENDICES\\Appendix A - Limitations_5_1_08.docIPEC Page 1 of 1 Print Date: 4/29/2008

FINAL QUARTERLY LONG-TERM GROUNDWATER MONITORING REPORT Q1 THROUGH Q4 2011 (REPORT NO. 13)

APPENDIX B: 2011 TRANSDUCER INSTALLATION LOGS

FINAL QUARTERLY LONG-TERM GROUNDWATER MONITORING REPORT Q1 THROUGH Q4 2011 (REPORT NO. 13)

APPENDIX B: Q1-2011 TRANSDUCER INSTALLATION LOGS

Client WELL ID I-2n 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 41.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 80.92 DATE 3/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 82.23 SERIAL NUMBER 16587 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 54.48 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

41.00 FT CONNECTOR GROUND ELEVATION:

80.92 FT M.S.L.

CASING ELEVATION:

82.23 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

1.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:49 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

27.75 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

27.750 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

82.23 FT M.S.L.

DEPTH TO WATER:

27.75 FT REFERENCE ELEVATION:

=

54.48 FT M.S.L.

TEST NAME:

I-2n PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:49 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

I-2n TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-36-24 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 54.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 11.799 DATE 3/7/11 PSI CAPACITY 30 CASING ELEVATION (FT) 11.598 SERIAL NUMBER 5376 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 7.54 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

24.00 FT CONNECTOR GROUND ELEVATION:

11.799 FT M.S.L.

CASING ELEVATION:

11.598 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.201 FT GROUND FT SURFACE TIME OF MEASUREMENT:

13:30 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

4.06 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

4.060 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

11.598 FT M.S.L.

DEPTH TO WATER:

4.06 FT REFERENCE ELEVATION:

=

7.538 FT M.S.L.

TEST NAME:

MW-36-24 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:30 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-36-24 Transducer was pulled out last quarter after Unit 2 transformer explosion released electrolytic fluid (oil) and 14' of product was found in MW-36 Wells.

Transducer was reinstalled on 3/7/11.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-41-40 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 64.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 54.87 DATE 2/14/11 PSI CAPACITY 30 CASING ELEVATION (FT) 54.13 SERIAL NUMBER 6321 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 33.00 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.00 FT CONNECTOR GROUND ELEVATION:

54.87 FT M.S.L.

CASING ELEVATION:

54.13 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.74 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:07 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

21.13 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

21.130 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

54.13 FT M.S.L.

DEPTH TO WATER:

21.13 FT REFERENCE ELEVATION:

=

33.00 FT M.S.L.

TEST NAME:

MW-41-40 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:07 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-41-40 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW42-78 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 80.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 69.714 DATE 3/4/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.524 SERIAL NUMBER 16626 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 36.93 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

78.00 FT CONNECTOR GROUND ELEVATION:

69.71 FT M.S.L.

CASING ELEVATION:

69.52 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.19 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:02 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

32.59 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

32.590 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.524 FT M.S.L.

DEPTH TO WATER:

32.59 FT REFERENCE ELEVATION:

=

36.934 FT M.S.L.

TEST NAME:

MW42-78 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:02 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-42-78 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-43-28 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 63.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 48.760 DATE 2/15/11 PSI CAPACITY 30 CASING ELEVATION (FT) 48.021 SERIAL NUMBER 11331 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 33.09 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

28.00 FT CONNECTOR GROUND ELEVATION:

48.760 FT M.S.L.

CASING ELEVATION:

48.021 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.739 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:22 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

14.93 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

14.930 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

48.021 FT M.S.L.

DEPTH TO WATER:

14.93 FT REFERENCE ELEVATION:

=

33.091 FT M.S.L.

TEST NAME:

MW-43-28 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:22 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-43-28 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-43-28 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 63.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 48.760 DATE 3/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 48.021 SERIAL NUMBER 11331 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 33.76 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

28.00 FT CONNECTOR GROUND ELEVATION:

48.760 FT M.S.L.

CASING ELEVATION:

48.021 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.739 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:29 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

14.26 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

14.260 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

48.021 FT M.S.L.

DEPTH TO WATER:

14.26 FT REFERENCE ELEVATION:

=

33.761 FT M.S.L.

TEST NAME:

MW-43-28 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:29 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-43-28 Transducer off by 18.357'.

Reset Transducer.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-50-66 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 67.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.92 DATE 2/25/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.61 SERIAL NUMBER 14459 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 4.76 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

65.75 FT CONNECTOR GROUND ELEVATION:

14.92 FT M.S.L.

CASING ELEVATION:

14.61 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:02 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

9.85 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

9.850 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.614 FT M.S.L.

DEPTH TO WATER:

9.85 FT REFERENCE ELEVATION:

=

4.764 FT M.S.L.

TEST NAME:

MW-50-66 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:02 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-50-66 Could not connect upon arrival. Replaced batteries.

No test running to extract data, extracted "abandoned" test, added new test.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-53-120 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 124.70 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 70.260 DATE 3/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 70.190 SERIAL NUMBER 6097 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 12.04 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

120.00 FT CONNECTOR GROUND ELEVATION:

70.260 FT M.S.L.

CASING ELEVATION:

70.190 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.07 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:06 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

58.15 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

58.150 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

70.190 FT M.S.L.

DEPTH TO WATER:

58.15 FT REFERENCE ELEVATION:

=

12.04 FT M.S.L.

TEST NAME:

MW53-120 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:06 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-53-120 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-55-24 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 77.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 18.25 DATE 2/3/11 PSI CAPACITY 30 CASING ELEVATION (FT) 17.77 SERIAL NUMBER 13988 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 6.96 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

24.00 FT CONNECTOR GROUND ELEVATION:

18.25 FT M.S.L.

CASING ELEVATION:

17.77 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.48 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:00 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

10.81 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

10.81 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

17.77 FT M.S.L.

DEPTH TO WATER:

10.81 FT REFERENCE ELEVATION:

=

6.96 FT M.S.L.

TEST NAME:

MW-55-24 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:00 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-55-24 Data off by 0.969'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-55-24 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 77.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 18.25 DATE 3/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 17.77 SERIAL NUMBER 13988 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 9.01 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

24.00 FT CONNECTOR GROUND ELEVATION:

18.25 FT M.S.L.

CASING ELEVATION:

17.77 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.48 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:50 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

8.76 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

8.76 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

17.77 FT M.S.L.

DEPTH TO WATER:

8.76 FT REFERENCE ELEVATION:

=

9.01 FT M.S.L.

TEST NAME:

MW-55-24 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:50 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-55-24 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-55-35 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 77.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 18.25 DATE PSI CAPACITY 30 CASING ELEVATION (FT) 17.77 SERIAL NUMBER CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 8.54 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

35.00 FT CONNECTOR GROUND ELEVATION:

18.25 FT M.S.L.

CASING ELEVATION:

17.77 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.48 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

12:04 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

9.23 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

9.23 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

17.77 FT M.S.L.

DEPTH TO WATER:

9.23 FT REFERENCE ELEVATION:

=

8.54 FT M.S.L.

TEST NAME:

MW-55-35 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

12:04 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-55-35 Unable to connect upon arrival. Replace batteries and tried again but unable to connect.

Checked cable connection: loose connection. Tried ten cable connection and was able to connect.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-62-18 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 38.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.69 DATE 2/24/11 PSI CAPACITY 30 CASING ELEVATION (FT) 12.81 SERIAL NUMBER 4859 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION 1.21 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

18.00 FT CONNECTOR GROUND ELEVATION:

14.69 FT M.S.L.

CASING ELEVATION:

12.81 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.88 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:35 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

11.60 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

11.600 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

12.81 FT M.S.L.

DEPTH TO WATER:

11.60 FT REFERENCE ELEVATION:

=

1.21 FT M.S.L.

TEST NAME:

MW-62-18 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:35 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-62-18 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID OUT-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 8.20 DATE 3/3/11 PSI CAPACITY 30 CASING ELEVATION (FT) 11.89 SERIAL NUMBER 16044 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 1.88 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

8.20 FT M.S.L.

CASING ELEVATION:

11.89 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.69 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

14:06 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

10.01 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

10.010 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

11.891 FT M.S.L.

DEPTH TO WATER:

10.010 FT REFERENCE ELEVATION:

=

1.881 FT M.S.L.

TEST NAME:

OUT-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

14:06 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

OUT-1 Organic material growing on transducer and cable.

Cleaned organic material off transducer.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U3-C1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

NA DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.003 DATE 3/911 PSI CAPACITY 30 CASING ELEVATION (FT) 18.060 SERIAL NUMBER 5548 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 4.79 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

NA FT CONNECTOR GROUND ELEVATION:

15.003 FT M.S.L.

CASING ELEVATION:

18.060 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.057 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

14:34 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

13.27 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

13.270 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.060 FT M.S.L.

DEPTH TO WATER:

13.27 FT REFERENCE ELEVATION:

=

4.790 FT M.S.L.

TEST NAME:

U3-C1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

14:34 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-C1 Unable to connect upon arrival. Replace batteries and tried again.

Able to connect to transducer.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U3-C1-2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

NA DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.003 DATE 3/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.060 SERIAL NUMBER 11949 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 4.78 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

NA FT CONNECTOR GROUND ELEVATION:

15.003 FT M.S.L.

CASING ELEVATION:

18.060 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.057 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

13.28 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

13.280 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.060 FT M.S.L.

DEPTH TO WATER:

13.28 FT REFERENCE ELEVATION:

=

4.780 FT M.S.L.

TEST NAME:

U3-C1-2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

14:18 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-C1-2 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID U3-4D 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 27.25 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.849 DATE 2/17/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.519 SERIAL NUMBER 14301 CASING DIAMETER (INCH) 4 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 4.21 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

27.25 FT CONNECTOR GROUND ELEVATION:

14.849 FT M.S.L.

CASING ELEVATION:

14.519 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.330 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

9:48 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

10.31 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

10.310 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.519 FT M.S.L.

DEPTH TO WATER:

10.31 FT REFERENCE ELEVATION:

=

4.209 FT M.S.L.

TEST NAME:

U3-4D PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

12:15 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-4D TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

FINAL QUARTERLY LONG-TERM GROUNDWATER MONITORING REPORT Q1 THROUGH Q4 2011 (REPORT NO. 13)

APPENDIX B: Q2-2011 TRANSDUCER INSTALLATION LOGS

Client WELL ID HR-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 16642 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 1.57 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

15:07 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

16.93 FT ACTUAL DEPTH:

+

41.314 FT THEORETICAL CABLE LENGTH:

=

58.244 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

16.93 FT REFERENCE ELEVATION:

=

1.57 FT M.S.L.

TEST NAME:

HR-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

15:07 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 Replaced transducer; moved from MW-57-45.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID I-2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 41.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 80.92 DATE 5/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 82.23 SERIAL NUMBER 11998 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 53.02 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.40 FT CONNECTOR GROUND ELEVATION:

80.92 FT M.S.L.

CASING ELEVATION:

82.23 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

1.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:15 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

29.21 FT ACTUAL DEPTH:

+

9.816 FT THEORETICAL CABLE LENGTH:

=

39.026 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

82.23 FT M.S.L.

DEPTH TO WATER:

29.21 FT REFERENCE ELEVATION:

=

53.02 FT M.S.L.

TEST NAME:

I-2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:15 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

I-2 Replaced batteries.

DTB =40.40' TOC.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID I-2n 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 41.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 80.92 DATE 5/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 82.23 SERIAL NUMBER 16587 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 53.02 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.40 FT CONNECTOR GROUND ELEVATION:

80.92 FT M.S.L.

CASING ELEVATION:

82.23 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

1.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:15 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

29.21 FT ACTUAL DEPTH:

+

9.816 FT THEORETICAL CABLE LENGTH:

=

39.026 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

82.23 FT M.S.L.

DEPTH TO WATER:

29.21 FT REFERENCE ELEVATION:

=

53.02 FT M.S.L.

TEST NAME:

I-2n PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:25 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

I-2n Replaced batteries.

DTB =40.40' TOC.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-36-24 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 54.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 11.799 DATE 4/28/11 PSI CAPACITY 30 CASING ELEVATION (FT) 11.598 SERIAL NUMBER 5376 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 7.26 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

24.00 FT CONNECTOR GROUND ELEVATION:

11.799 FT M.S.L.

CASING ELEVATION:

11.598 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.201 FT GROUND FT SURFACE TIME OF MEASUREMENT:

13:04 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

4.34 FT ACTUAL DEPTH:

+

13.785 FT THEORETICAL CABLE LENGTH:

=

18.125 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

11.598 FT M.S.L.

DEPTH TO WATER:

4.34 FT REFERENCE ELEVATION:

=

7.258 FT M.S.L.

TEST NAME:

MW-36-24 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:09 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-36-24 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-36-24 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 54.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 11.799 DATE 5/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 11.598 SERIAL NUMBER 5376 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 7.50 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

24.00 FT CONNECTOR GROUND ELEVATION:

11.799 FT M.S.L.

CASING ELEVATION:

11.598 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.201 FT GROUND FT SURFACE TIME OF MEASUREMENT:

11:24 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

4.10 FT ACTUAL DEPTH:

+

15.227 FT THEORETICAL CABLE LENGTH:

=

19.327 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

11.598 FT M.S.L.

DEPTH TO WATER:

4.10 FT REFERENCE ELEVATION:

=

7.498 FT M.S.L.

TEST NAME:

MW-36-24 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:24 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-36-24 DTB = 24.22.

Replaced batteries.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-37-22 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 57.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.021 DATE 5/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.852 SERIAL NUMBER 6753 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT)

  • 5.89 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

22.00 FT CONNECTOR GROUND ELEVATION:

15.021 FT M.S.L.

CASING ELEVATION:

14.852 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.17 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:22 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

8.96 FT ACTUAL DEPTH:

+

12.91 FT THEORETICAL CABLE LENGTH:

=

21.87 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.852

  • FT M.S.L.

DEPTH TO WATER:

8.96 FT REFERENCE ELEVATION:

=

5.892

  • FT M.S.L.

TEST NAME:

MW37-22 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:22 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-37-22 DTB = 22.21' TOC.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-37-32 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 57.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.021 DATE 5/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.791 SERIAL NUMBER 6100 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 5.86 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

32.00 FT CONNECTOR GROUND ELEVATION:

15.021 FT M.S.L.

CASING ELEVATION:

14.791 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.230 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:30 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

8.93 FT ACTUAL DEPTH:

+

15.593 FT THEORETICAL CABLE LENGTH:

=

24.523 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.791 FT M.S.L.

DEPTH TO WATER:

8.93 FT REFERENCE ELEVATION:

=

5.861 FT M.S.L.

TEST NAME:

MW-37-32 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:30 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-37-32 DTB = 31.99' TOC.

Replaced Batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-37-40 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 57.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.021 DATE 5/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.852 SERIAL NUMBER 2280 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT)

  • 7.81 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.00 FT CONNECTOR GROUND ELEVATION:

15.021 FT M.S.L.

CASING ELEVATION:

14.852 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.169 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:53 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

7.04

  • FT ACTUAL DEPTH:

+

32.392 FT THEORETICAL CABLE LENGTH:

=

39.432 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.852 FT M.S.L.

DEPTH TO WATER:

7.04

  • FT REFERENCE ELEVATION:

=

7.812

  • FT M.S.L.

TEST NAME:

MW-37-40 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:53 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-37-40 DTB = 41.20' TOC.

Replaced batteries.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-37-57 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 57.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.021 DATE 5/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.788 SERIAL NUMBER 11802 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 7.04 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

56.50 FT CONNECTOR GROUND ELEVATION:

15.021 FT M.S.L.

CASING ELEVATION:

14.788 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.233 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:03 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

7.75 FT ACTUAL DEPTH:

+

42.879 FT THEORETICAL CABLE LENGTH:

=

50.629 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.788 FT M.S.L.

DEPTH TO WATER:

7.75 FT REFERENCE ELEVATION:

=

7.038 FT M.S.L.

TEST NAME:

MW-37-57 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:03 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-37-57 DTB = 56.44' TOC.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-38 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 40.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.342 DATE 5/11/11 PSI CAPACITY 30 CASING ELEVATION (FT) 13.999 SERIAL NUMBER 4386 CASING DIAMETER (INCH) 4 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 4.28 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

39.02 FT CONNECTOR GROUND ELEVATION:

14.342 FT M.S.L.

CASING ELEVATION:

13.999 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.34 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:38 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

9.71 FT ACTUAL DEPTH:

+

28.229 FT THEORETICAL CABLE LENGTH:

=

37.939 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

13.990 FT M.S.L.

DEPTH TO WATER:

9.71 FT REFERENCE ELEVATION:

=

4.280 FT M.S.L.

TEST NAME:

MW-38 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:42 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-38 Batteries dead upon arrival; some moisture on dead batteries but still working.

Replaced batteries and able to connect; downloaded data.

DTB = 39.45'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-41-40 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 64.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 54.87 DATE 4/20/11 PSI CAPACITY 30 CASING ELEVATION (FT) 54.13 SERIAL NUMBER 6321 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 34.61 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.00 FT CONNECTOR GROUND ELEVATION:

54.87 FT M.S.L.

CASING ELEVATION:

54.13 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.74 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:33 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

19.52 FT ACTUAL DEPTH:

+

65.433 FT THEORETICAL CABLE LENGTH:

=

84.953 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

54.13 FT M.S.L.

DEPTH TO WATER:

19.52 FT REFERENCE ELEVATION:

=

34.61 FT M.S.L.

TEST NAME:

MW-41-40 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:48 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-41-40 Transducer off by 3.752'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-41-40 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 64.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 54.87 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 54.13 SERIAL NUMBER 6321 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 32.61 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.00 FT CONNECTOR GROUND ELEVATION:

54.87 FT M.S.L.

CASING ELEVATION:

54.13 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.74 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:32 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

21.52 FT ACTUAL DEPTH:

+

64.212 FT THEORETICAL CABLE LENGTH:

=

85.732 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

54.13 FT M.S.L.

DEPTH TO WATER:

21.52 FT REFERENCE ELEVATION:

=

32.61 FT M.S.L.

TEST NAME:

MW-41-40 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:36 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-41-40 DTB = 40.89'.

Transducer off by -1.238.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-41-63 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 64.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 54.87 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 54.13 SERIAL NUMBER 5977 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 29.00 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

63.00 FT CONNECTOR GROUND ELEVATION:

54.87 FT M.S.L.

CASING ELEVATION:

54.13 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.74 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:48 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

25.13 FT ACTUAL DEPTH:

+

16.158 FT THEORETICAL CABLE LENGTH:

=

41.288 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

54.13 FT M.S.L.

DEPTH TO WATER:

25.13 FT REFERENCE ELEVATION:

=

29.00 FT M.S.L.

TEST NAME:

MW-41-63 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:51 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-41-63 DTB = 62.29.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW42-78 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 80.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 69.714 DATE 4/21/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.524 SERIAL NUMBER 16626 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 37.08 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

78.00 FT CONNECTOR GROUND ELEVATION:

69.71 FT M.S.L.

CASING ELEVATION:

69.52 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.19 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

12:47 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

32.44 FT ACTUAL DEPTH:

+

45.180 FT THEORETICAL CABLE LENGTH:

=

77.620 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.524 FT M.S.L.

DEPTH TO WATER:

32.44 FT REFERENCE ELEVATION:

=

37.084 FT M.S.L.

TEST NAME:

MW42-78 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

12:51 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-42-78 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW42-78 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 80.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 69.714 DATE 5/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.524 SERIAL NUMBER 16626 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 36.23 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

78.00 FT CONNECTOR GROUND ELEVATION:

69.71 FT M.S.L.

CASING ELEVATION:

69.52 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.19 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

14:50 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

33.29 FT ACTUAL DEPTH:

+

44.047 FT THEORETICAL CABLE LENGTH:

=

77.337 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.524 FT M.S.L.

DEPTH TO WATER:

33.29 FT REFERENCE ELEVATION:

=

36.234 FT M.S.L.

TEST NAME:

MW42-78 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

14:54 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-42-78 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-43-28 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 63.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 48.760 DATE 4/21/11 PSI CAPACITY 30 CASING ELEVATION (FT) 48.021 SERIAL NUMBER 11331 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 33.45 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

28.00 FT CONNECTOR GROUND ELEVATION:

48.760 FT M.S.L.

CASING ELEVATION:

48.021 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.739 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:33 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

14.57 FT ACTUAL DEPTH:

+

17.996 FT THEORETICAL CABLE LENGTH:

=

32.566 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

48.021 FT M.S.L.

DEPTH TO WATER:

14.57 FT REFERENCE ELEVATION:

=

33.451 FT M.S.L.

TEST NAME:

MW-43-28 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:33 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-43-28 Transducer was off by 7.639'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-43-28 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 63.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 48.760 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 48.021 SERIAL NUMBER 11331 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 32.77 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

28.00 FT CONNECTOR GROUND ELEVATION:

48.760 FT M.S.L.

CASING ELEVATION:

48.021 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.739 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

15:25 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

15.25 FT ACTUAL DEPTH:

+

36.522 FT THEORETICAL CABLE LENGTH:

=

51.772 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

48.021 FT M.S.L.

DEPTH TO WATER:

15.25 FT REFERENCE ELEVATION:

=

32.771 FT M.S.L.

TEST NAME:

MW-43-28 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

15:25 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-43-28 DTB = 28.38'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-43-62 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 63.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 48.761 DATE 4/21/11 PSI CAPACITY 30 CASING ELEVATION (FT) 47.821 SERIAL NUMBER 16236 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 32.54 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

63.00 FT CONNECTOR GROUND ELEVATION:

48.761 FT M.S.L.

CASING ELEVATION:

47.821 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.940 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:49 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

15.28 FT ACTUAL DEPTH:

+

37.184 FT THEORETICAL CABLE LENGTH:

=

52.464 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

47.821 FT M.S.L.

DEPTH TO WATER:

15.28 FT REFERENCE ELEVATION:

=

32.541 FT M.S.L.

TEST NAME:

MW-43-62 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:50 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-43-62 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-43-62 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 63.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 48.761 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 47.821 SERIAL NUMBER 16236 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 32.17 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

63.00 FT CONNECTOR GROUND ELEVATION:

48.761 FT M.S.L.

CASING ELEVATION:

47.821 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.940 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

14:30 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

15.65 FT ACTUAL DEPTH:

+

36.682 FT THEORETICAL CABLE LENGTH:

=

52.332 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

47.821 FT M.S.L.

DEPTH TO WATER:

15.65 FT REFERENCE ELEVATION:

=

32.171 FT M.S.L.

TEST NAME:

MW-43-62 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

14:30 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-43-62 DTB = 62.98'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-44-67 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 105.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 93.52 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 93.02 SERIAL NUMBER 16108 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 33.66 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

67.00 FT CONNECTOR GROUND ELEVATION:

93.52 FT M.S.L.

CASING ELEVATION:

93.02 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

0.50 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:44 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

59.36 FT ACTUAL DEPTH:

+

33.620 FT THEORETICAL CABLE LENGTH:

=

92.980 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

93.02 FT M.S.L.

DEPTH TO WATER:

59.36 FT REFERENCE ELEVATION:

=

33.66 FT M.S.L.

TEST NAME:

MW-44-67 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:44 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-44-67 DTB = 66.50'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-44-102 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 102.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 93.52 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 93.09 SERIAL NUMBER 15940 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 26.48 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

102.00 FT CONNECTOR GROUND ELEVATION:

93.52 FT M.S.L.

CASING ELEVATION:

93.09 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.43 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:23 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

66.61 FT ACTUAL DEPTH:

+

32.025 FT THEORETICAL CABLE LENGTH:

=

98.635 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

93.09 FT M.S.L.

DEPTH TO WATER:

66.61 FT REFERENCE ELEVATION:

=

26.48 FT M.S.L.

TEST NAME:

MW-44-102 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:23 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-44-102 DTB = 102.16'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-45-42 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 65.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 53.66 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 53.20 SERIAL NUMBER 6082 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 29.83 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

42.00 FT CONNECTOR GROUND ELEVATION:

53.66 FT M.S.L.

CASING ELEVATION:

53.20 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.46 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

12:43 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

23.37 FT ACTUAL DEPTH:

+

17.557 FT THEORETICAL CABLE LENGTH:

=

40.927 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

53.20 FT M.S.L.

DEPTH TO WATER:

23.37 FT REFERENCE ELEVATION:

=

29.83 FT M.S.L.

TEST NAME:

MW-45-42 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

12:45 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-45-42 DTB = 41.83'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-45-61 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 67.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 53.662 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 53.217 SERIAL NUMBER 16930 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 29.34 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

61.00 FT CONNECTOR GROUND ELEVATION:

53.662 FT M.S.L.

CASING ELEVATION:

53.217 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.45 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

12:57 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

23.880 FT ACTUAL DEPTH:

+

41.338 FT THEORETICAL CABLE LENGTH:

=

65.218 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

53.217 FT M.S.L.

DEPTH TO WATER:

23.88 FT REFERENCE ELEVATION:

=

29.337 FT M.S.L.

TEST NAME:

MW-45-61 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:00 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-45-61 DTB = 61.23'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-46 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 30.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 18.08 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 16.97 SERIAL NUMBER 4424 CASING DIAMETER (INCH) 4 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 12.72 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

29.82 FT CONNECTOR GROUND ELEVATION:

18.08 FT M.S.L.

CASING ELEVATION:

16.97 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

DISTANCE FROM CASING TO GROUND (+ OR -):

-1.11 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:50 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

4.25 FT ACTUAL DEPTH:

+

12.71 FT THEORETICAL CABLE LENGTH:

=

16.96 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

16.97 FT M.S.L.

DEPTH TO WATER:

4.25 FT REFERENCE ELEVATION:

=

12.72 FT M.S.L.

TEST NAME:

MW-46 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:50 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-46 DTB = 29.54' TOC.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-47-80 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 80.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 70.32 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.742 SERIAL NUMBER 9445 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 24.83 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

80.00 FT CONNECTOR GROUND ELEVATION:

70.32 FT M.S.L.

CASING ELEVATION:

69.742 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.58 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

08:58 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

44.91 FT ACTUAL DEPTH:

+

6.141 FT THEORETICAL CABLE LENGTH:

=

51.051 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.742 FT M.S.L.

DEPTH TO WATER:

44.91 FT REFERENCE ELEVATION:

=

24.832 FT M.S.L.

TEST NAME:

MW-47-80 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

08:58 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-47-80 DTB = 80.15'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-49-26 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 26.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.650 DATE 5/11/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.171 SERIAL NUMBER 11948 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 2.17 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

26.00 FT CONNECTOR GROUND ELEVATION:

14.650 FT M.S.L.

CASING ELEVATION:

14.171 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.48 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:06 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

12.00 FT ACTUAL DEPTH:

+

12.525 FT THEORETICAL CABLE LENGTH:

=

24.525 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.17 FT M.S.L.

DEPTH TO WATER:

12.00 FT REFERENCE ELEVATION:

=

2.17 FT M.S.L.

TEST NAME:

MW-49-26 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:06 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-49-26 DTB = 25.96'.

Replaced Batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW49-42 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 66.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.650 DATE 5/11/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.223 SERIAL NUMBER 5395 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 2.16 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

66.00 FT CONNECTOR GROUND ELEVATION:

14.650 FT M.S.L.

CASING ELEVATION:

14.223 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.43 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:35 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

12.06 FT ACTUAL DEPTH:

+

15.450 FT THEORETICAL CABLE LENGTH:

=

27.510 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.223 FT M.S.L.

DEPTH TO WATER:

12.06 FT REFERENCE ELEVATION:

=

2.163 FT M.S.L.

TEST NAME:

MW49-42 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:35 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-49-42 DTB = 42.03'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-49-65 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 66.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.650 DATE 5/11/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.457 SERIAL NUMBER 15847 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 2.34 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

65.50 FT CONNECTOR GROUND ELEVATION:

14.650 FT M.S.L.

CASING ELEVATION:

14.457 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.19 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:23 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

12.12 FT ACTUAL DEPTH:

+

13.78 FT THEORETICAL CABLE LENGTH:

=

25.90 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.457 FT M.S.L.

DEPTH TO WATER:

12.12 FT REFERENCE ELEVATION:

=

2.337 FT M.S.L.

TEST NAME:

MW-49-65 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:23 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-49-65 DTB = 65.56'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-50-66 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 67.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.92 DATE 5/3/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.61 SERIAL NUMBER 14459 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 4.72 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

65.75 FT CONNECTOR GROUND ELEVATION:

14.92 FT M.S.L.

CASING ELEVATION:

14.61 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:58 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

9.89 FT ACTUAL DEPTH:

+

89.503 FT THEORETICAL CABLE LENGTH:

=

99.393 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.614 FT M.S.L.

DEPTH TO WATER:

9.89 FT REFERENCE ELEVATION:

=

4.724 FT M.S.L.

TEST NAME:

MW-50-66 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:59 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-50-66 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-50-66 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 67.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.92 DATE 5/16/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.61 SERIAL NUMBER 14459 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 5.48 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

65.75 FT CONNECTOR GROUND ELEVATION:

14.92 FT M.S.L.

CASING ELEVATION:

14.61 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:48 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

9.13 FT ACTUAL DEPTH:

+

89.892 FT THEORETICAL CABLE LENGTH:

=

99.022 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.614 FT M.S.L.

DEPTH TO WATER:

9.13 FT REFERENCE ELEVATION:

=

5.484 FT M.S.L.

TEST NAME:

MW-50-66 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:48 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-50-66 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS DTB = 65.74' TOC.

Replaced batteries.

Client WELL ID MW-52-11 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 12.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 16.77 DATE 5/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 16.28 SERIAL NUMBER 14150 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 8.13 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

11.00 FT CONNECTOR GROUND ELEVATION:

16.77 FT M.S.L.

CASING ELEVATION:

16.28 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.49 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:23 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

8.15 FT ACTUAL DEPTH:

+

1.748 FT THEORETICAL CABLE LENGTH:

=

9.90 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

16.28 FT M.S.L.

DEPTH TO WATER:

8.15 FT REFERENCE ELEVATION:

=

8.13 FT M.S.L.

TEST NAME:

MW-52-12 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:23 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-52-11 Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-53-82 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 124.70 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 70.26 DATE 5/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.93 SERIAL NUMBER 11897 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 11.01 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

82.00 FT CONNECTOR GROUND ELEVATION:

70.26 FT M.S.L.

CASING ELEVATION:

69.93 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.33 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:35 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

58.92 FT ACTUAL DEPTH:

+

22.828 FT THEORETICAL CABLE LENGTH:

=

81.748 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.93 FT M.S.L.

DEPTH TO WATER:

58.92 FT REFERENCE ELEVATION:

=

11.01 FT M.S.L.

TEST NAME:

MW-53-82 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:35 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-53-82 DTB = 82.91'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-53-120 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 124.70 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 70.260 DATE 5/9/11 PSI CAPACITY 30 CASING ELEVATION (FT) 70.190 SERIAL NUMBER 6097 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 10.61 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

120.00 FT CONNECTOR GROUND ELEVATION:

70.260 FT M.S.L.

CASING ELEVATION:

70.190 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.07 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:12 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

59.58 FT ACTUAL DEPTH:

+

57.803 FT THEORETICAL CABLE LENGTH:

=

117.383 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

70.190 FT M.S.L.

DEPTH TO WATER:

59.58 FT REFERENCE ELEVATION:

=

10.61 FT M.S.L.

TEST NAME:

MW53-120 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:12 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-53-120 DTB = 119.25' TOC/

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-56-53 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 88.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 70.26 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.32 SERIAL NUMBER 16499 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 24.16 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

53.00 FT CONNECTOR GROUND ELEVATION:

70.26 FT M.S.L.

CASING ELEVATION:

69.32 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.94 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:19 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

45.16 FT ACTUAL DEPTH:

+

-18.867 FT THEORETICAL CABLE LENGTH:

=

26.293 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.32 FT M.S.L.

DEPTH TO WATER:

45.16 FT REFERENCE ELEVATION:

=

24.16 FT M.S.L.

TEST NAME:

MW-56-53 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:20 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-56-53 DTB = 53.48; unable to connect prior to replacing batteries.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-56-83 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 88.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 70.258 DATE 4/27/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.207 SERIAL NUMBER 16394 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 25.78 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

83.00 FT CONNECTOR GROUND ELEVATION:

70.258 FT M.S.L.

CASING ELEVATION:

69.207 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.05 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:40 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

43.43 FT ACTUAL DEPTH:

+

40.079 FT THEORETICAL CABLE LENGTH:

=

83.509 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.207 FT M.S.L.

DEPTH TO WATER:

43.43 FT REFERENCE ELEVATION:

=

25.777 FT M.S.L.

TEST NAME:

MW-56-83 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:43 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-56-83 Transducer was off by -5.158' before resetting.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-56-83 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 88.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 70.258 DATE 5/10/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.207 SERIAL NUMBER 16394 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 23.35 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

83.00 FT CONNECTOR GROUND ELEVATION:

70.258 FT M.S.L.

CASING ELEVATION:

69.207 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.05 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:44 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

45.86 FT ACTUAL DEPTH:

+

37.667 FT THEORETICAL CABLE LENGTH:

=

83.527 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.207 FT M.S.L.

DEPTH TO WATER:

45.86 FT REFERENCE ELEVATION:

=

23.347 FT M.S.L.

TEST NAME:

MW-56-83 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:04 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-56-83 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS DTB = 82.93'.

Replaced batteries.

Client WELL ID MW-57-11 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 46.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.98 DATE 5/16/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.73 SERIAL NUMBER 16389 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 10.33 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

11.00 FT CONNECTOR GROUND ELEVATION:

14.98 FT M.S.L.

CASING ELEVATION:

14.73 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.25 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:11 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

4.40 FT ACTUAL DEPTH:

+

39.946 FT THEORETICAL CABLE LENGTH:

=

44.346 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.73 FT M.S.L.

DEPTH TO WATER:

4.40 FT REFERENCE ELEVATION:

=

10.33 FT M.S.L.

TEST NAME:

MW-57-11 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:11 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-57-11 DTB = 11.06' TOC.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-58-26 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 72.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.57 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.23 SERIAL NUMBER 3114 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 7.17 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

26.00 FT CONNECTOR GROUND ELEVATION:

14.57 FT M.S.L.

CASING ELEVATION:

14.23 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.34 FT GROUND FT SURFACE TIME OF MEASUREMENT:

13:11 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

7.06 FT ACTUAL DEPTH:

+

17.937 FT THEORETICAL CABLE LENGTH:

=

24.997 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.23 FT M.S.L.

DEPTH TO WATER:

7.06 FT REFERENCE ELEVATION:

=

7.17 FT M.S.L.

TEST NAME:

MW-58-26 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:11 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-58-26 DTB = 25.93'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-58-65 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 72.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.57 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.25 SERIAL NUMBER 5619 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 6.96 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

65.00 FT CONNECTOR GROUND ELEVATION:

14.57 FT M.S.L.

CASING ELEVATION:

14.25 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.32 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:38 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

7.29 FT ACTUAL DEPTH:

+

6.966 FT THEORETICAL CABLE LENGTH:

=

14.256 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.25 FT M.S.L.

DEPTH TO WATER:

7.29 FT REFERENCE ELEVATION:

=

6.96 FT M.S.L.

TEST NAME:

MW-58-65 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:38 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-58-65 DTB = 64.67'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-62-18 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 38.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.69 DATE 4/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 12.81 SERIAL NUMBER 4859 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION 2.90 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

18.00 FT CONNECTOR GROUND ELEVATION:

14.69 FT M.S.L.

CASING ELEVATION:

12.81 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.88 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

9.91 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

9.910 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

12.81 FT M.S.L.

DEPTH TO WATER:

9.91 FT REFERENCE ELEVATION:

=

2.90 FT M.S.L.

TEST NAME:

MW-62-18 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:58 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-62-18 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-62-18 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 38.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.69 DATE 5/11/11 PSI CAPACITY 30 CASING ELEVATION (FT) 12.81 SERIAL NUMBER 4859 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION 0.88 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

18.00 FT CONNECTOR GROUND ELEVATION:

14.69 FT M.S.L.

CASING ELEVATION:

12.81 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.88 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

14:18 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

11.93 FT ACTUAL DEPTH:

+

4.511 FT THEORETICAL CABLE LENGTH:

=

16.441 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

12.81 FT M.S.L.

DEPTH TO WATER:

11.93 FT REFERENCE ELEVATION:

=

0.88 FT M.S.L.

TEST NAME:

MW-62-18 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

14:18 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-62-18 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS DTB = 17.3' TOC.

Replaced batteries.

Client WELL ID MW-62-37 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 38.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.69 DATE 5/11/11 PSI CAPACITY 30 CASING ELEVATION (FT) 12.81 SERIAL NUMBER 5441 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION

  • 1.44 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

38.00 FT CONNECTOR GROUND ELEVATION:

14.69 FT M.S.L.

CASING ELEVATION:

12.81 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.88 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:54 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

11.37 FT ACTUAL DEPTH:

+

11.259 FT THEORETICAL CABLE LENGTH:

=

22.629 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

12.81 FT M.S.L.

DEPTH TO WATER:

11.37 FT REFERENCE ELEVATION:

=

1.44 FT M.S.L.

TEST NAME:

MW-62-37 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:54 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-62-37 DTB = 36.02'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-63-18 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 35.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.18 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 13.06 SERIAL NUMBER 16104 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION 2.68 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

18.00 FT CONNECTOR GROUND ELEVATION:

14.18 FT M.S.L.

CASING ELEVATION:

13.06 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.12 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:03 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

10.38 FT ACTUAL DEPTH:

+

6.816 FT THEORETICAL CABLE LENGTH:

=

17.196 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

13.06 FT M.S.L.

DEPTH TO WATER:

10.38 FT REFERENCE ELEVATION:

=

2.68 FT M.S.L.

TEST NAME:

MW-63-18 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:03 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-63-18 DTB = 17.50' TOC.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-63-35 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 35.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.18 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 13.06 SERIAL NUMBER 5359 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION 2.62 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

34.00 FT CONNECTOR GROUND ELEVATION:

14.18 FT M.S.L.

CASING ELEVATION:

13.06 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.12 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:19 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

10.44 FT ACTUAL DEPTH:

+

14.226 FT THEORETICAL CABLE LENGTH:

=

24.666 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

13.06 FT M.S.L.

DEPTH TO WATER:

10.44 FT REFERENCE ELEVATION:

=

2.62 FT M.S.L.

TEST NAME:

MW-63-34 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:19 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-63-35 DTB = 34.05' TOC.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-66-21 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 37.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.122 DATE 5/11/11 PSI CAPACITY 30 CASING ELEVATION (FT) 13.407 SERIAL NUMBER 15849 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 1.52 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

21.00 FT CONNECTOR GROUND ELEVATION:

14.122 FT M.S.L.

CASING ELEVATION:

13.407 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.72 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

12:07 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

11.89 FT ACTUAL DEPTH:

+

8.673 FT THEORETICAL CABLE LENGTH:

=

20.56 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

13.407 FT M.S.L.

DEPTH TO WATER:

11.89 FT REFERENCE ELEVATION:

=

1.517 FT M.S.L.

TEST NAME:

MW-66-21 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

12:07 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-66-21 DTB = 20.85'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-66-36 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 37.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.122 DATE 5/11/11 PSI CAPACITY 30 CASING ELEVATION (FT) 13.364 SERIAL NUMBER 11840 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 1.72 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

36.00 FT CONNECTOR GROUND ELEVATION:

14.122 FT M.S.L.

CASING ELEVATION:

13.364 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.76 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

11:35 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

11.64 FT ACTUAL DEPTH:

+

12.733 FT THEORETICAL CABLE LENGTH:

=

24.37 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

13.364 FT M.S.L.

DEPTH TO WATER:

11.64 FT REFERENCE ELEVATION:

=

1.724 FT M.S.L.

TEST NAME:

MW-66-36 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:35 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-66-36 DTB = 36.24'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-107 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 37.90 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 140.061 DATE 5/2/11 PSI CAPACITY 30 CASING ELEVATION (FT) 142.757 SERIAL NUMBER 5746 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 120.78 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

37.90 FT CONNECTOR GROUND ELEVATION:

140.061 FT M.S.L.

CASING ELEVATION:

142.757 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

2.696 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

08:07 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

21.98 FT ACTUAL DEPTH:

+

-6.703 FT THEORETICAL CABLE LENGTH:

=

15.277 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

142.757 FT M.S.L.

DEPTH TO WATER:

21.98 FT REFERENCE ELEVATION:

=

120.777 FT M.S.L.

TEST NAME:

MW-107 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

08:14 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-107 Transducer off by +26.549' actual depth was -6.703 after resetting transducer.

Note: rechecked calculations and still same result; bad transducer?

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-107 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 37.90 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 140.061 DATE 5/17/11 PSI CAPACITY 30 CASING ELEVATION (FT) 142.757 SERIAL NUMBER 5746 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 120.82 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

37.90 FT CONNECTOR GROUND ELEVATION:

140.061 FT M.S.L.

CASING ELEVATION:

142.757 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

2.696 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:43 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

21.94 FT ACTUAL DEPTH:

+

-6.700 FT THEORETICAL CABLE LENGTH:

=

15.240 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

142.757 FT M.S.L.

DEPTH TO WATER:

21.94 FT REFERENCE ELEVATION:

=

120.817 FT M.S.L.

TEST NAME:

MW-107 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:43 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-107 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS DTB = 38.29'; TOC.

Replaced batteries.

Client WELL ID MW-108 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 11.90 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.48 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.23 SERIAL NUMBER 20738 CASING DIAMETER (INCH) 4 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 9.44 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

11.60 FT CONNECTOR GROUND ELEVATION:

14.48 FT M.S.L.

CASING ELEVATION:

14.23 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.25 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

4.79 FT ACTUAL DEPTH:

+

6.390 FT THEORETICAL CABLE LENGTH:

=

11.18 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.23 FT M.S.L.

DEPTH TO WATER:

4.79 FT REFERENCE ELEVATION:

=

9.44 FT M.S.L.

TEST NAME:

MW-108 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-108 DTB = 11.36'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID OUT-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 8.20 DATE 5/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 11.89 SERIAL NUMBER 16044 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 5.45 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

8.20 FT M.S.L.

CASING ELEVATION:

11.89 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.69 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:08 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

6.44 FT ACTUAL DEPTH:

+

49.557 FT THEORETICAL CABLE LENGTH:

=

55.997 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

11.891 FT M.S.L.

DEPTH TO WATER:

6.440 FT REFERENCE ELEVATION:

=

5.451 FT M.S.L.

TEST NAME:

OUT-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:08 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

OUT-1 Replaced batteries.

Little organic build up on transducer.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U1CSS 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

NA DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.088 DATE 5/4/11 PSI CAPACITY 30 CASING ELEVATION (FT) 20.073 SERIAL NUMBER 13911 CASING DIAMETER (INCH) 4 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 18.63 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

NA FT CONNECTOR GROUND ELEVATION:

15.088 FT M.S.L.

CASING ELEVATION:

20.073 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

4.985 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:48 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

1.44 FT ACTUAL DEPTH:

+

12.735 FT THEORETICAL CABLE LENGTH:

=

14.175 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

20.073 FT M.S.L.

DEPTH TO WATER:

1.44 FT REFERENCE ELEVATION:

=

18.633 FT M.S.L.

TEST NAME:

U1CSS PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:56 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U1CSS TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U1CSS 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

NA DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.088 DATE 5/16/11 PSI CAPACITY 30 CASING ELEVATION (FT) 20.073 SERIAL NUMBER 13911 CASING DIAMETER (INCH) 4 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 14.37 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

NA FT CONNECTOR GROUND ELEVATION:

15.088 FT M.S.L.

CASING ELEVATION:

20.073 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

4.985 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:35 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

5.70 FT ACTUAL DEPTH:

+

8.481 FT THEORETICAL CABLE LENGTH:

=

14.181 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

20.073 FT M.S.L.

DEPTH TO WATER:

5.70 FT REFERENCE ELEVATION:

=

14.373 FT M.S.L.

TEST NAME:

U1CSS PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:35 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U1CSS TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS DTB = 15.05'.

Replaced batteries.

Client WELL ID U3-C1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

NA DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.003 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.060 SERIAL NUMBER 5548 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 3.62 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

NA FT CONNECTOR GROUND ELEVATION:

15.003 FT M.S.L.

CASING ELEVATION:

18.060 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.057 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:55 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

14.44 FT ACTUAL DEPTH:

+

14.931 FT THEORETICAL CABLE LENGTH:

=

29.371 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.060 FT M.S.L.

DEPTH TO WATER:

14.44 FT REFERENCE ELEVATION:

=

3.620 FT M.S.L.

TEST NAME:

U3-C1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:55 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-C1 DTB =

Replaced batteries.

Some organic build up on transducer.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U3-C1-2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

NA DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.003 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.060 SERIAL NUMBER 11949 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 3.53 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

NA FT CONNECTOR GROUND ELEVATION:

15.003 FT M.S.L.

CASING ELEVATION:

18.060 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.057 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:05 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

14.53 FT ACTUAL DEPTH:

+

-15.643 FT THEORETICAL CABLE LENGTH:

=

-1.113 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.060 FT M.S.L.

DEPTH TO WATER:

14.53 FT REFERENCE ELEVATION:

=

3.530 FT M.S.L.

TEST NAME:

U3-C1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:05 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-C1 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS Replaced batteries.

Some organic build up on transducer.

Client WELL ID U3-3 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 14.15 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.849 DATE 5/17/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.599 SERIAL NUMBER 4318 CASING DIAMETER (INCH) 6 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 7.92 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

14.15 FT CONNECTOR GROUND ELEVATION:

14.849 FT M.S.L.

CASING ELEVATION:

14.599 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.250 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:31 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

6.68 FT ACTUAL DEPTH:

+

10.041 FT THEORETICAL CABLE LENGTH:

=

16.721 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.599 FT M.S.L.

DEPTH TO WATER:

6.68 FT REFERENCE ELEVATION:

=

7.919 FT M.S.L.

TEST NAME:

U3-3 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:31 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U-3-3 DTB = 14.30'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U3-4D 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 27.25 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.849 DATE 5/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.519 SERIAL NUMBER 14301 CASING DIAMETER (INCH) 4 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 5.00 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

27.25 FT CONNECTOR GROUND ELEVATION:

14.849 FT M.S.L.

CASING ELEVATION:

14.519 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.330 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:25 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

9.52 FT ACTUAL DEPTH:

+

51.911 FT THEORETICAL CABLE LENGTH:

=

61.431 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.519 FT M.S.L.

DEPTH TO WATER:

9.52 FT REFERENCE ELEVATION:

=

4.999 FT M.S.L.

TEST NAME:

U3-4D PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:25 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-4D DTB = 26.85'.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U3-T1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 2.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 3.267 DATE 5/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 8.518 SERIAL NUMBER 3062 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 5.26 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

2.00 FT CONNECTOR GROUND ELEVATION:

3.267 FT M.S.L.

CASING ELEVATION:

8.518 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

5.251 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:55 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

3.26 FT ACTUAL DEPTH:

+

3.758 FT THEORETICAL CABLE LENGTH:

=

7.018 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

8.518 FT M.S.L.

DEPTH TO WATER:

3.26 FT REFERENCE ELEVATION:

=

5.258 FT M.S.L.

TEST NAME:

U3-T1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:55 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U-3-T1 DTB = 6.88' TOC.

Replaced batteries.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U3-T2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 2.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 3.259 DATE 5/6/11 PSI CAPACITY 30 CASING ELEVATION (FT) 8.512 SERIAL NUMBER 16240 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 2.20 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

2.00 FT CONNECTOR GROUND ELEVATION:

3.259 FT M.S.L.

CASING ELEVATION:

8.512 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

5.253 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:05 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

6.31 FT ACTUAL DEPTH:

+

2.866 FT THEORETICAL CABLE LENGTH:

=

9.176 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

8.512 FT M.S.L.

DEPTH TO WATER:

6.31 FT REFERENCE ELEVATION:

=

2.202 FT M.S.L.

TEST NAME:

U3-T2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:09 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-T2 Transducer was off by -2.583'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U3-T2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 2.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 3.259 DATE 5/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 8.512 SERIAL NUMBER 16240 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 5.43 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

2.00 FT CONNECTOR GROUND ELEVATION:

3.259 FT M.S.L.

CASING ELEVATION:

8.512 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

5.253 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:42 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

3.08 FT ACTUAL DEPTH:

+

3.602 FT THEORETICAL CABLE LENGTH:

=

6.682 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

8.512 FT M.S.L.

DEPTH TO WATER:

3.08 FT REFERENCE ELEVATION:

=

5.432 FT M.S.L.

TEST NAME:

U3-T2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:42 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-T2 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS DTB = 6.81' TOC.

Replaced batteries.

FINAL QUARTERLY LONG-TERM GROUNDWATER MONITORING REPORT Q1 THROUGH Q4 2011 (REPORT NO. 13)

APPENDIX B: Q3-2011 TRANSDUCER INSTALLATION LOGS

Client WELL ID HR-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 8/17/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 16642 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT)

-0.31 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

08:25 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

18.81 FT ACTUAL DEPTH:

+

45.400 FT THEORETICAL CABLE LENGTH:

=

64.210 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

18.81 FT REFERENCE ELEVATION:

=

-0.31 FT M.S.L.

TEST NAME:

HR-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

08:25 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 Off by 6.121'; heavy organic build up on transducer.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID HR-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 8/19/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 16642 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 2.96 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

15:26 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

15.54 FT ACTUAL DEPTH:

+

39.953

  • FT THEORETICAL CABLE LENGTH:

=

55.493 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

15.54 FT REFERENCE ELEVATION:

=

2.96 FT M.S.L.

TEST NAME:

HR-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

15:26 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 Transducer set at ~21' from TOC.

  • Most likely transducer is a non-venting transducer installed on a venting cable. Actual depth is erroneous.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID HR-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 8/23/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 16642 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 0.78 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

09:03 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

17.72 FT ACTUAL DEPTH:

+

37.295

  • FT THEORETICAL CABLE LENGTH:

=

55.015 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

17.72 FT REFERENCE ELEVATION:

=

0.78 FT M.S.L.

TEST NAME:

HR-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:03 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID HR-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 9/6/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 16642 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 0.27 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

10:42 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

18.23 FT ACTUAL DEPTH:

+

38.522

  • FT THEORETICAL CABLE LENGTH:

=

56.752 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

18.23 FT REFERENCE ELEVATION:

=

0.27 FT M.S.L.

TEST NAME:

HR-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:42 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 Extended drop pipe PVC casing by 5'. Total length = 24.25' TOC.

Transducer reading off by 1.79' prior to lengthening drop pipe and reinstallation.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID HR-1 #2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 8/22/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 2280 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 0.28 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

08:58 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

18.22 FT ACTUAL DEPTH:

+

3.195

  • FT THEORETICAL CABLE LENGTH:

=

21.415 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

18.22 FT REFERENCE ELEVATION:

=

0.28 FT M.S.L.

TEST NAME:

HR-1 #2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

08:58 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 #2 Installed transducer at 22' from TOC.

Pulled transducer from MW-37-40 for installation at HR-1 #2.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID HR-1 #2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 8/23/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 2280 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 0.62 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

09:13 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

17.88 FT ACTUAL DEPTH:

+

1.666

  • FT THEORETICAL CABLE LENGTH:

=

19.546 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

17.88 FT REFERENCE ELEVATION:

=

0.62 FT M.S.L.

TEST NAME:

HR-1 #2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:13 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 #2 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID HR-1 #2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 9/6/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 2280 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 0.29 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

10:37 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

18.21 FT ACTUAL DEPTH:

+

3.321

  • FT THEORETICAL CABLE LENGTH:

=

21.531 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

18.21 FT REFERENCE ELEVATION:

=

0.29 FT M.S.L.

TEST NAME:

HR-1 #2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:37 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 #2 Extended drop pipe PVC casing by 5'. Total length = 24.25' TOC.

Transducer reading off by 2.423' prior to lengthening drop pipe and reinstallation.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-36-24 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 54.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 11.799 DATE 8/16/11 PSI CAPACITY 30 CASING ELEVATION (FT) 11.598 SERIAL NUMBER 5376 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 8.12 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

24.00 FT CONNECTOR GROUND ELEVATION:

11.799 FT M.S.L.

CASING ELEVATION:

11.598 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.201 FT GROUND FT SURFACE TIME OF MEASUREMENT:

11:42 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

3.48 FT ACTUAL DEPTH:

+

21.376 FT THEORETICAL CABLE LENGTH:

=

24.856 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

11.598 FT M.S.L.

DEPTH TO WATER:

3.48 FT REFERENCE ELEVATION:

=

8.118 FT M.S.L.

TEST NAME:

MW-36-24 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:44 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-36-24 Transducer off by -5.50'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-37-40 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 57.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.021 DATE 8/16/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.852 SERIAL NUMBER 2280 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT)

  • 7.07 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.00 FT CONNECTOR GROUND ELEVATION:

15.021 FT M.S.L.

CASING ELEVATION:

14.852 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.169 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:11 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

7.78

  • FT ACTUAL DEPTH:

+

31.909 FT THEORETICAL CABLE LENGTH:

=

39.691 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.852 FT M.S.L.

DEPTH TO WATER:

7.78

  • FT REFERENCE ELEVATION:

=

7.070

  • FT M.S.L.

TEST NAME:

MW-37-40 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:11 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-37-40 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-41-40 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 64.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 54.87 DATE 7/15/11 PSI CAPACITY 30 CASING ELEVATION (FT) 54.13 SERIAL NUMBER 6321 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 33.13 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.00 FT CONNECTOR GROUND ELEVATION:

54.87 FT M.S.L.

CASING ELEVATION:

54.13 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.74 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:40 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

21.00 FT ACTUAL DEPTH:

+

68.874 FT THEORETICAL CABLE LENGTH:

=

89.874 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

54.13 FT M.S.L.

DEPTH TO WATER:

21.00 FT REFERENCE ELEVATION:

=

33.13 FT M.S.L.

TEST NAME:

MW-41-40 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:40 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-41-40 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-41-40 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 64.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 54.87 DATE 8/4/11 PSI CAPACITY 30 CASING ELEVATION (FT) 54.13 SERIAL NUMBER 6321 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 33.48 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.00 FT CONNECTOR GROUND ELEVATION:

54.87 FT M.S.L.

CASING ELEVATION:

54.13 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.74 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:15 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

20.65 FT ACTUAL DEPTH:

+

70.491 FT THEORETICAL CABLE LENGTH:

=

91.141 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

54.13 FT M.S.L.

DEPTH TO WATER:

20.65 FT REFERENCE ELEVATION:

=

33.48 FT M.S.L.

TEST NAME:

MW-41-40 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:21 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-41-40 Transducer off by -1.273'.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID MW-43-28 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 63.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 48.760 DATE 8/4/11 PSI CAPACITY 30 CASING ELEVATION (FT) 48.021 SERIAL NUMBER 11331 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 48.02 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

28.00 FT CONNECTOR GROUND ELEVATION:

48.760 FT M.S.L.

CASING ELEVATION:

48.021 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.739 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

0.000 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

48.021 FT M.S.L.

DEPTH TO WATER:

0.00 FT REFERENCE ELEVATION:

=

48.021 FT M.S.L.

TEST NAME:

MW-43-28 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-43-28 Off by 26.92', last reset transducer was off by 7.639'.

Pulled transducer out of service. Data progressively off.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-43-62 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 63.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 48.761 DATE 8/4/11 PSI CAPACITY 30 CASING ELEVATION (FT) 47.821 SERIAL NUMBER 16236 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 31.34 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

63.00 FT CONNECTOR GROUND ELEVATION:

48.761 FT M.S.L.

CASING ELEVATION:

47.821 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.940 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:11 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

16.48 FT ACTUAL DEPTH:

+

36.213 FT THEORETICAL CABLE LENGTH:

=

52.693 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

47.821 FT M.S.L.

DEPTH TO WATER:

16.48 FT REFERENCE ELEVATION:

=

31.341 FT M.S.L.

TEST NAME:

MW-43-62 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:11 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-43-62 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-44-102 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 102.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 93.52 DATE 8/22/11 PSI CAPACITY 30 CASING ELEVATION (FT) 93.09 SERIAL NUMBER 15940 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 31.70 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

102.00 FT CONNECTOR GROUND ELEVATION:

93.52 FT M.S.L.

CASING ELEVATION:

93.09 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.43 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:35 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

61.39 FT ACTUAL DEPTH:

+

37.369 FT THEORETICAL CABLE LENGTH:

=

98.759 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

93.09 FT M.S.L.

DEPTH TO WATER:

61.39 FT REFERENCE ELEVATION:

=

31.70 FT M.S.L.

TEST NAME:

MW-44-102 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:36 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-44-102 Transducer off by +2.532'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-46 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 30.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 18.08 DATE 7/13/11 PSI CAPACITY 30 CASING ELEVATION (FT) 16.97 SERIAL NUMBER 4424 CASING DIAMETER (INCH) 4 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 13.19 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

29.82 FT CONNECTOR GROUND ELEVATION:

18.08 FT M.S.L.

CASING ELEVATION:

16.97 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

DISTANCE FROM CASING TO GROUND (+ OR -):

-1.11 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:20 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

3.78 FT ACTUAL DEPTH:

+

23.99 FT THEORETICAL CABLE LENGTH:

=

27.77 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

16.97 FT M.S.L.

DEPTH TO WATER:

3.78 FT REFERENCE ELEVATION:

=

13.19 FT M.S.L.

TEST NAME:

MW-46 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:20 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-46 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-50-66 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 67.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.92 DATE 9/6/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.61 SERIAL NUMBER 14459 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 10.65 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

65.75 FT CONNECTOR GROUND ELEVATION:

14.92 FT M.S.L.

CASING ELEVATION:

14.61 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:47 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

3.964 FT ACTUAL DEPTH:

+

88.667 FT THEORETICAL CABLE LENGTH:

=

92.631 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.614 FT M.S.L.

DEPTH TO WATER:

3.96 FT REFERENCE ELEVATION:

=

10.650 FT M.S.L.

TEST NAME:

MW-50-66 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:47 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-50-66 Transducer reading off by 0.314'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-55-54 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 77.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 18.25 DATE 8/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 17.77 SERIAL NUMBER CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 9.27 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

54.00 FT CONNECTOR GROUND ELEVATION:

18.25 FT M.S.L.

CASING ELEVATION:

17.77 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.48 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:46 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

8.50 FT ACTUAL DEPTH:

+

41.092 FT THEORETICAL CABLE LENGTH:

=

49.59 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

17.77 FT M.S.L.

DEPTH TO WATER:

8.50 FT REFERENCE ELEVATION:

=

9.27 FT M.S.L.

TEST NAME:

MW-55-54 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:46 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-55-54 TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-56-53 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 88.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 70.26 DATE 7/6/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.32 SERIAL NUMBER 16437 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 23.61 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

53.00 FT CONNECTOR GROUND ELEVATION:

70.26 FT M.S.L.

CASING ELEVATION:

69.32 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.94 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:48 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

45.71 FT ACTUAL DEPTH:

+

39.640 FT THEORETICAL CABLE LENGTH:

=

85.350 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.32 FT M.S.L.

DEPTH TO WATER:

45.71 FT REFERENCE ELEVATION:

=

23.61 FT M.S.L.

TEST NAME:

MW-56-53 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:00 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-56-53 Reinstalled spare transducer to remedie issues (Serial #16437).

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-57-11 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 46.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.98 DATE 8/19/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.73 SERIAL NUMBER 16389 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 12.06 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

11.00 FT CONNECTOR GROUND ELEVATION:

14.98 FT M.S.L.

CASING ELEVATION:

14.73 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.25 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

08:54 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

2.67 FT ACTUAL DEPTH:

+

41.952 FT THEORETICAL CABLE LENGTH:

=

44.622 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.73 FT M.S.L.

DEPTH TO WATER:

2.67 FT REFERENCE ELEVATION:

=

12.06 FT M.S.L.

TEST NAME:

MW-57-11 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

08:54 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-57-11 Off by -0.314.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-62-37 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 38.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.69 DATE 8/4/11 PSI CAPACITY 30 CASING ELEVATION (FT) 12.81 SERIAL NUMBER 5441 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION

  • 2.42 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

38.00 FT CONNECTOR GROUND ELEVATION:

14.69 FT M.S.L.

CASING ELEVATION:

12.81 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.88 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

12:02 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

10.39 FT ACTUAL DEPTH:

+

12.238 FT THEORETICAL CABLE LENGTH:

=

22.628 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

12.81 FT M.S.L.

DEPTH TO WATER:

10.39 FT REFERENCE ELEVATION:

=

2.42 FT M.S.L.

TEST NAME:

MW-62-37 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

12:02 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-62-37 Reset clock on transducer.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID OUT-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 8.20 DATE 8/31/11 PSI CAPACITY 30 CASING ELEVATION (FT) 11.89 SERIAL NUMBER 16044 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 6.68 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

8.20 FT M.S.L.

CASING ELEVATION:

11.89 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.69 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:24 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

5.21 FT ACTUAL DEPTH:

+

49.486 FT THEORETICAL CABLE LENGTH:

=

54.696 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

11.891 FT M.S.L.

DEPTH TO WATER:

5.210 FT REFERENCE ELEVATION:

=

6.681 FT M.S.L.

TEST NAME:

OUT-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:24 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

OUT-1 Transducer off by 0.645'; transducer original set at 18.3' from TOC.

PVC drop pip = 13.8'; transducer reinstalled at 17.25' from TOC.

Some organic build up on transducer.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID TIW-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 77.50 DATE 7/11/11 PSI CAPACITY 30 CASING ELEVATION (FT) 76.583 SERIAL NUMBER 11998 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 49.99 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

25.59 FT CONNECTOR GROUND ELEVATION:

77.50 FT M.S.L.

CASING ELEVATION:

76.583 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

-0.917 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:19 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

26.59 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

26.590 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

76.583 FT M.S.L.

DEPTH TO WATER:

26.59 FT REFERENCE ELEVATION:

=

49.993 FT M.S.L.

TEST NAME:

TIW-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:19 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

TIW-1 Transducer installed. All measurements are from TOC.

TOC is 11" below ground surface. Casing elevation calculated using known ground elevation of 77.50' and measured distance.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID TIW-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 77.50 DATE 9/8/11 PSI CAPACITY 30 CASING ELEVATION (FT) 76.583 SERIAL NUMBER 11998 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 50.48 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

25.59 FT CONNECTOR GROUND ELEVATION:

77.50 FT M.S.L.

CASING ELEVATION:

76.583 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

-0.917 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:05 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

26.10 FT ACTUAL DEPTH:

+

0.080 FT THEORETICAL CABLE LENGTH:

=

26.180 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

76.583 FT M.S.L.

DEPTH TO WATER:

26.10 FT REFERENCE ELEVATION:

=

50.483 FT M.S.L.

TEST NAME:

TIW-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:05 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

TIW-1 Transducer reading off by 0.48'.

Well dry.

Some condensation accumulating on vault lid and dripping into vault.

TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS

Client WELL ID I-2n 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 41.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 80.92 DATE 8/12/11 PSI CAPACITY 30 CASING ELEVATION (FT) 82.230 SERIAL NUMBER 16587 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 54.26 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

41.00 FT CONNECTOR GROUND ELEVATION:

80.92 FT M.S.L.

CASING ELEVATION:

82.230 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

1.310 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:05 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

27.97 FT ACTUAL DEPTH:

+

44.812 FT THEORETICAL CABLE LENGTH:

=

72.782 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

82.230 FT M.S.L.

DEPTH TO WATER:

27.97 FT REFERENCE ELEVATION:

=

54.260 FT M.S.L.

TEST NAME:

I-2n PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:03 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

I-2n TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS Transducer off by +0.860.

FINAL QUARTERLY LONG-TERM GROUNDWATER MONITORING REPORT Q1 THROUGH Q4 2011 (REPORT NO. 13)

APPENDIX B: Q4-2011 TRANSDUCER INSTALLATION LOGS

Client WELL ID HR-1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 12/15/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 16642 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 3.90 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

13:35 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

14.60 FT ACTUAL DEPTH:

+

-20.912 FT THEORETICAL CABLE LENGTH:

=

-6.312 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

14.60 FT REFERENCE ELEVATION:

=

3.90 FT M.S.L.

TEST NAME:

HR-1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:35 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 Transducer reading serverly off. Off by 63.017'.

Transducer reading surface at -59.121'. Consider replacement of transducer.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID HR-1 #2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.99 DATE 12/15/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.50 SERIAL NUMBER 2280 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 3.90 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

FT CONNECTOR GROUND ELEVATION:

14.99 FT M.S.L.

CASING ELEVATION:

18.50 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.50 FT GROUND MEASURED CABLE LENGTH FT SURFACE TIME OF MEASUREMENT:

13:25 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

14.60 FT ACTUAL DEPTH:

+

7.245 FT THEORETICAL CABLE LENGTH:

=

21.845 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.50 FT M.S.L.

DEPTH TO WATER:

14.60 FT REFERENCE ELEVATION:

=

3.896 FT M.S.L.

TEST NAME:

HR-1 #2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:26 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

HR-1 #2 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS Transducer reading off by 0.359'. No organic build up observed on transducer.

Client WELL ID MW-41-40 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 64.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 54.87 DATE 11/28/11 PSI CAPACITY 30 CASING ELEVATION (FT) 54.13 SERIAL NUMBER 6329 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 33.53 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

40.00 FT CONNECTOR GROUND ELEVATION:

54.87 FT M.S.L.

CASING ELEVATION:

54.13 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.74 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

12:35 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

20.60 FT ACTUAL DEPTH:

+

77.960 FT THEORETICAL CABLE LENGTH:

=

98.560 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

54.13 FT M.S.L.

DEPTH TO WATER:

20.60 FT REFERENCE ELEVATION:

=

33.53 FT M.S.L.

TEST NAME:

MW-41-40 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

12:35 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-41-40 Transducer reading off by 5.495'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-44-102 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 102.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 93.52 DATE 12/1/11 PSI CAPACITY 30 CASING ELEVATION (FT) 93.09 SERIAL NUMBER 15940 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 28.65 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

102.00 FT CONNECTOR GROUND ELEVATION:

93.52 FT M.S.L.

CASING ELEVATION:

93.09 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.43 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:11 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

64.44 FT ACTUAL DEPTH:

+

34.247 FT THEORETICAL CABLE LENGTH:

=

98.687 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

93.09 FT M.S.L.

DEPTH TO WATER:

64.44 FT REFERENCE ELEVATION:

=

28.65 FT M.S.L.

TEST NAME:

MW-44-102 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:12 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-44-102 Transducer reading was off by 16.738'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW49-42 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 66.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.650 DATE 11/4/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.223 SERIAL NUMBER 5395 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 1.86 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

66.00 FT CONNECTOR GROUND ELEVATION:

14.650 FT M.S.L.

CASING ELEVATION:

14.223 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.43 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

10:09 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

12.36 FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

12.360 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.223 FT M.S.L.

DEPTH TO WATER:

12.36 FT REFERENCE ELEVATION:

=

1.863 FT M.S.L.

TEST NAME:

MW49-42 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

10:09 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-49-42 Transducer off by 0.459'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-50-66 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 67.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 14.92 DATE 10/27/11 PSI CAPACITY 30 CASING ELEVATION (FT) 14.61 SERIAL NUMBER 14459 CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 4.66 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

65.75 FT CONNECTOR GROUND ELEVATION:

14.92 FT M.S.L.

CASING ELEVATION:

14.61 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-0.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:35 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

9.95 FT ACTUAL DEPTH:

+

89.024 FT THEORETICAL CABLE LENGTH:

=

98.974 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

14.614 FT M.S.L.

DEPTH TO WATER:

9.95 FT REFERENCE ELEVATION:

=

4.664 FT M.S.L.

TEST NAME:

MW-50-66 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:35 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-50-66 Transducer reading off by 0.345'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID MW-56-83 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 88.50 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 70.258 DATE 10/31/11 PSI CAPACITY 30 CASING ELEVATION (FT) 69.207 SERIAL NUMBER CASING DIAMETER (INCH) 1 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 27.89 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

83.00 FT CONNECTOR GROUND ELEVATION:

70.258 FT M.S.L.

CASING ELEVATION:

69.207 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

below DISTANCE FROM CASING TO GROUND (+ OR -):

-1.05 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

11:03 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

41.32 FT ACTUAL DEPTH:

+

42.584 FT THEORETICAL CABLE LENGTH:

=

83.904 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

69.207 FT M.S.L.

DEPTH TO WATER:

41.32 FT REFERENCE ELEVATION:

=

27.887 FT M.S.L.

TEST NAME:

MW-56-83 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

11:13 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

MW-56-83 Non-vented transducer.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID I-2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 41.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 80.92 DATE 12/08/11 PSI CAPACITY 30 CASING ELEVATION (FT) 82.23 SERIAL NUMBER 16587 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 52.81 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

41.00 FT CONNECTOR GROUND ELEVATION:

80.92 FT M.S.L.

CASING ELEVATION:

82.23 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

1.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

13:48 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

29.42 FT ACTUAL DEPTH:

+

43.501 FT THEORETICAL CABLE LENGTH:

=

72.921 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

82.23 FT M.S.L.

DEPTH TO WATER:

29.42 FT REFERENCE ELEVATION:

=

52.81 FT M.S.L.

TEST NAME:

I-2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

13:48 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

I-2 Transducer reading off by 1.142'.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID I-2n 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT) 41.00 DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 80.92 DATE 11/18/11 PSI CAPACITY 30 CASING ELEVATION (FT) 82.23 SERIAL NUMBER 16587 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 49.91 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

41.00 FT CONNECTOR GROUND ELEVATION:

80.92 FT M.S.L.

CASING ELEVATION:

82.23 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

1.31 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

14:50 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

32.32 FT ACTUAL DEPTH:

+

41.737 FT THEORETICAL CABLE LENGTH:

=

74.057 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

82.23 FT M.S.L.

DEPTH TO WATER:

32.32 FT REFERENCE ELEVATION:

=

49.91 FT M.S.L.

TEST NAME:

I-2n PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

14:50 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

I-2n TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS Tansducer reading off by 1.23'.

Client WELL ID U3-C1 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

NA DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.003 DATE 12/16/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.060 SERIAL NUMBER 5548 CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 18.06 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

NA FT CONNECTOR GROUND ELEVATION:

15.003 FT M.S.L.

CASING ELEVATION:

18.060 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.057 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

FT ACTUAL DEPTH:

+

FT THEORETICAL CABLE LENGTH:

=

0.000 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.060 FT M.S.L.

DEPTH TO WATER:

0.00 FT REFERENCE ELEVATION:

=

18.060 FT M.S.L.

TEST NAME:

U3-C1 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-C1 No connection upon arrival. Replaced batteries. Noticed break in cable sheathing. By passed transducer cable and connected directly to transducer to download data. Most recent test was abended. Previous two tests were abended, three consecutive tests have been abended and batteries were replaced all three times. Pulled transducer due to draining of batteries frequently.

TRANSDUCER INSTALLATION LOG SCIENTISTS AND ENGINEERS GZA GEOENVIRONMENTAL OF NEW YORK Entergy

Client WELL ID U3-C1-2 440 NINTH AVENUE, 18th FLOOR SHEET 1 of 1 NEW YORK, NEW YORK 10001 Indian Point Energy Center FILE NO.

01.0017869.92 PROJECT LOCATION Indian Point MANUFACTURER In-Situ FINAL BORING DEPTH (FT)

NA DATUM NGVD 29 MAKE MiniTroll GROUND ELEVATION (FT) 15.003 DATE 12/16/11 PSI CAPACITY 30 CASING ELEVATION (FT) 18.060 SERIAL NUMBER CASING DIAMETER (INCH) 2 C. Benmergui STATIC GROUNDWATER TABLE ELEVATION (FT) 0.97 GZA ENGINEER S. Lee ELEVATION OF MEASURING POINT - DEPTH TO WATER = REFERENCE ELEVATION (WATER TABLE ELEVATION)

DEPTH TO WATER + ACTUAL DEPTH = CABLE LENGTH (if transducer is functioning properly)

CABLE DEPTH TO BOTTOM:

NA FT CONNECTOR GROUND ELEVATION:

15.003 FT M.S.L.

CASING ELEVATION:

18.060 FT M.S.L.

CASING ABOVE (+) OR BELOW (-) GROUND:

above DISTANCE FROM CASING TO GROUND (+ OR -):

3.057 FT GROUND MEASURED CABLE LENGTH:

FT SURFACE TIME OF MEASUREMENT:

09:20 HRS MEASUREMENT TAKEN FROM:

TOC WATER TABLE DEPTH TO WATER:

17.09 FT ACTUAL DEPTH:

+

32.973 FT THEORETICAL CABLE LENGTH:

=

50.063 FT HAVE CLOCKS BEEN SYNCHRONIZED?

check IS TRANSDUCER SET TO TAKE "SURFACE" READINGS?

check CABLE ELEVATION OF MEASURING POINT:

18.060 FT M.S.L.

DEPTH TO WATER:

17.09 FT REFERENCE ELEVATION:

=

0.970 FT M.S.L.

TEST NAME:

U3-C1-2 PRESSURE LOGGING INTERVAL:

20 MIN TRANSDUCER TEST START TIME:

09:20 HRS SENSOR WELL BOTTOM LEGEND:

DTW - DEPTH TO WATER DTB - DEPTH TO BOTTOM OF WELL AD - ACTUAL DEPTH OF TRANSDUCER UNDER WATER CL - CABLE LENGTH FROM SENSOR TO GROUND SURFACE/ TOP OF CASING NOTES:

GZA WELL ID :

U3-C1-2 TRANSDUCER INSTALLATION LOG GZA GEOENVIRONMENTAL OF NEW YORK Entergy SCIENTISTS AND ENGINEERS Transducer severely off. Transducer reading surface at -26.448' CB.

Transducer off by 27.458'.

FINAL QUARTERLY LONG-TERM GROUNDWATER MONITORING REPORT Q1 THROUGH Q4 2011 (REPORT NO. 13)

APPENDIX C: 2011 CHAINS OF CUSTODY

FINAL QUARTERLY LONG-TERM GROUNDWATER MONITORING REPORT Q1 THROUGH Q4 2011 (REPORT NO. 13)

APPENDIX C: Q1-2011 CHAINS OF CUSTODY