GNRO-2012/00093, License Renewal Application 2012 Annual Update

From kanterella
(Redirected from ML12229A582)
Jump to navigation Jump to search
License Renewal Application 2012 Annual Update
ML12229A582
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 08/15/2012
From: Mike Perito
Entergy Operations
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
GNRO-2012/00093
Download: ML12229A582 (18)


Text

  • .~~~.Entergy GNRO-2012/00093 August 15, 2012 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Entergy Operations, Inc.

P. O. Box 756 Port Gibson. MS 39150 Michael Perito Vice President. Operations Grand Gulf Nuclear Station Tel. (601) 437~409

SUBJECT:

REFERENCE:

Dear Sir or Madam:

License Renewal Application 2012 Annual Update Grand Gulf Nuclear Station, Unit 1 Docket No. 50-416 License No. NPF-29 Letter to Nuclear Regulatory Commission, "License Renewal Application Grand Gulf Nuclear Station, Unit 1," dated October 28, 2011 (GNRO-2011/00093)

The purpose of this letter is to provide the Nuclear Regulatory Commission (NRC) an annual update to the referenced Grand Gulf Nuclear Station (GGNS) License Renewal Application (LRA), in accordance with 10 CFR 54.21 (b). During NRC review of the GGNS LRA, GGNS is required by 10 CFR 54.21 (b) to provide an annual report of changes to the GGNS current licensing basis (CLB) that materially affects the contents of the GGNS LRA, including the Final Safety Analysis Report supplement. GGNS has completed the annual CLB review and is providing, in the Attachment, the changes to the LRA required by this review This letter contains no new commitments. If you have any questions or require additional information, please contact Christina L. Perino at 601-437-6299.

I declare under penalty of perjury that the foregoing is true and correct. Executed on the 15th day of August, 2012.

MP/jas

Attachment:

(see next page)

GNRO-2012/00093 Page 2 of 2

Attachment:

CLB Changes to LRA cc: with Attachment Mr. John P. Boska, Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0-8-C2 Washington, DC 20555 cc: without Attachment Mr. Elmo E. Collins, Jr.

Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 U.S. Nuclear Regulatory Commission ATTN: Mr. A. Wang, NRRlDORL Mail Stop OWFN/8 G14 11555 Rockville Pike Rockville, MD 20852-2378 U.S. Nuclear Regulatory Commission ATTN: Mr. Nathaniel Ferrer NRRlDLR Mail Stop OWFNI 11 F1 11555 Rockville Pike Rockville, MD 20852-2378 NRC Senior Resident Inspector Grand Gulf Nuclear Station Port Gibson, MS 39150

Attachment GNRO-2012100093 CLB Changes to LRA

Attachment to GNRO-2012/00093 Page 1 of 15 The following changes are required for the Grand Gulf Nuclear Station (GGNS) License Renewal Application (LRA) in accordance with 10 CFR 54.21 (b) as a result of current license basis changes that have occurred at GGNS since the submittal of the license renewal application. This includes changes made during the recent extended power uprate outage. Changes are shown with strikethroughs for deletions and underlines for additions.

Table 2.3.3-6 Fuel Pool Cooling and Cleanup System Components Subject to Aging Management Review Component Type Intended Function Bolting Pressure boundary Diffuser Pressure boundary Flow element Pressure boundary

!=Ieat eKel=laRger (BeRRet)

Pressl:IFe B91:1RElary

!=Ieat eKel=laRger (sI=I911)

Pressl:Ire B91:1RElary

!=Ieat eKel=laRger (tl:lBe sl=Ieets)

Pressl:Ire B91:1RElary

!=Ieat eKel=laRger (tl:lBes)

Pressl:Ire B91:1RElary

!=Ieat traRsfer Heat exchanger (end covers)

Pressure boundary Heat exchanger (plates)

Pressure boundarv Heat transfer Neutron absorber Neutron absorption

en

~

s

~

~

~

<.J)

<.J)

<.J) 0z J!E ;

~ ;

~

~

~

~

~

~

~

.as ea-1-....

I E

~B

~

c

~B

~

~

~

~

T T

T CJcP

~

~

~

~

~

~

~

~

w=

a::....

~C)

(

(

(

(

Zco

~

~

§

§

~

j1

. I~

~

" Ig " Ig

~

!J 55 en J

i

(

1 I;1 I

i

" 5 I mEE

( 3 Is

( c 15 15 ((~I

( 3 e

cP ea

.- m"

(

(

i

{

11

(

(

meam Cel:!

i i c

c c

C ea~

1 1

I 1

4 ( I

(,

I 3Ie:

I

~

~

~

~ me e

cP f f

=.- E w.~

cP m~m

'(

'(

'(

'(

'(

e i ea e

lb l

l ma:: ea C

(

c

(

(

(

-u t

~~

~~

r:-

~:

~r:-

~~

11:-

~r:-

~v

~

e

~Ii

'v

~l:-

cP

(

c c

i E

c i

i i

i i

e

~IJ 0

i E

j

.s; e

.?

~

>0 W

<~

en I

I I

I I

Q,

~

i i Ji e

i jJ jJ jJ jJ j jJ II I

(3 cP

'0 1;

Ct) e 0) ea 0

m 0

.5 I I

~

'0 ia If If IfIf If If Jf if T""

0

'0:0=

0

(.)

e u C\\I

'0 cP e I0

-~

0

.Eu.

et

~

z

'ii

(!)

~

.91.0 U. -

~

D

'I 1

~

~

cD e

Il T""

I CP I J i

1 t I I I I e_

N al 0)0 C"i EC\\I C"i Q,>o I

I I

I

..c EI-1

(,)0)

J!

0 11 1

1 1

1 cae:>>

.a

(.)

~

l

~

~

~

~

=::ca ea j

j j

<<0..

I-

...J

Attachment to GNRO-2012/00093 Page 3 of 15 Table 3.3.2-6: Fuel Pool Cooling and Cleanup System Component Intended Aging Effect Aging NUREG-Table Material Environment Requiring Management Type Function Management Programs 1801 Item 1 Item Notes Heat exchanger Pressure Carbon steel Air - indoor [ext]

Loss of material External Surfaces VII.I.A-77 3.3.1-78 A-(end cover) boundary Monitoring Heat exchanger Pressure Carbon steel Treated water [int]

Loss of material Water Chemistry VII.E3.AP-106 3.3.1-21 C,301 (end cover) boundary Control -BWR Water Chemistry Heat exchanger Pressure Carbon steel Treated water [int]

Loss of material Control - Closed VII.A4.AP-189 3.3.1-46 A-(end cover) boundary Treated Water Systems Heat exchanger Pressure Stainless Air - indoor [ext]

None None VII.J.AP-123 3.3.1-120 C

(plates) boundary steel Heat exchanger Heat transfer Stainless Treated water [int]

Fouling Water Chemistry VII.A4.AP-139 3.3.1-17 C

(plates) steel Control -BWR Heat exchanger Pressure Stainless Treated water [int]

Loss of material Water Chemistry VII.A4.AP-111 3.3.1-25 A,301 (plates) boundary steel Control -BWR Water Chemistry Heat exchanger Heat transfer Stainless Treated water [int]

Fouling Control - Closed VII.C2.AP-188 3.3.1-50 Q

(plates) steel Treated Water Systems Water Chemistry Heat exchanger Pressure Stainless Treated water [int]

Loss of material Control - Closed VII.C2.A-52 3.3.1-49 Q

(plates) boundary steel Treated Water Systems

Attachment to GNRO-2012/00093 Page 4 of 15 Table 2.3.3-8 Component Cooling Water System Components SUbject to Aging Management Review Component Type Intended Function Bolting Pressure boundary Flow element Pressure boundary Piping Pressure boundary Strainer Housing Pressure boundary Strainer Filtration Tubing Pressure boundary Valve body Pressure boundary

Attachment to GNRO-2012/00093 Page 5 of 15 Table 3.3.2-8:

Component Cooling Water System Component Intended Aging Effect Aging NUREG-Table 1 Type Function Material Environment Requiring Management 1801 Item Item Notes Management Program Strainer Pressure Carbon steel Air-indoor Loss of material External Surfaces VII.I.A-77 3.3.1-78 A

housing boundary (ext)

Monitoring Water Chemistry Strainer Pressure Carbon steel Treated water Loss of material Control - Closed VII.C2.AP-202 3.3.1-45 A

housing boundary (int)

Treated Water Systems Water Chemistry Strainer Filtration Stainless steel Treated water Loss of material Control - Closed VII.C2.A-52 3.3.1-49 A

(int)

Treated Water Systems Water Chemistry Strainer Filtration Stainless steel Treated water Loss of material Control - Closed VII.C2.A-52 3.3.1-49 A

(ext)

Treated Water Systems

Attachment to GNRO-2012/00093 Page 6 of 15 Table 3.3.2-7:

Standby Service Water System Component Intended Aging Effect Aging NUREG-Table 1 Type Function Material Environment Requiring Management 1801 Item Item Notes Management Program Piping Pressure Stainless steel Condensation Loss of material External Surfaces G

boundary (ext)

Monitoring Piping Pressure Stainless steel Raw water (ext)

Loss of material Service Water VII.C1.A-54 3.3.1-40 A

boundary Integrity Piping Pressure Stainless steel Raw water (int)

Loss of material Service Water VII.C1.A-54 3.3.1-40 A

boundary Integrity Piping Pressure Stainless steel Soil (ext)

Loss of material Buried Piping and G

boundary Tanks Inspection Table 2.4-2 Water Control Structures Components SUbject to Aging Management Review Intended Function1 Cooling tower drift eliminators Heat sink Support for Criterion (a)(2) equipment

Attachment to GNRO-2012/00093 Page 7 of 15 Table 3.5.2-2 Water Control Structures Summary of Aging Management Evaluation Table 3.5.2-2:

Water Control Structures Structure Aging Effect Aging and/or Intended NUREG-Table 1 Component or Function Material Environment Requiring Management 1801 Item Item Notes Commodity Management Program Cooling tower drift HS,SNS Stainless Steel Exposed to fluid Loss of material Structures III.A8.T-23 3.5.1-52 g

eliminators environment monitorina

Attachment to GNRO-2012/00093 Page 8 of 15 Table 2.3.1-3 Reactor Coolant Pressure Boundary Components SUbject to Aging Management Review Component Type Intended Function Thermowell Pressure boundary TheFFReweli (ReR Class 1)

PFesslolFe gelolRElaFY

Attachment to GNRO-2012100093 Page 9 of 15 Table 3.1.2-3 Reactor Coolant Pressure Boundary Summary of Aging Management Evaluation Table 3.1.2-3:

Reactor Coolant Pressure Boundary Aging Effect Aging I

NUREG-I Table I

Notes Component Intended Material Environment Requiring Management 1801 Item 1 Item Type Function Management Program Air iREl99r Ex-terRal S...rlases I V.E.E 44 I 3.2.1 4Q I G;--143 Tl:lerm9well (R9R Press...re b9SS 9t material CarB9R steel (ext)

M9Rit9riRg Class 1)

B9...RElary Tl:lerm9well (R9R Press...re TreateEl water b9SS 9f material WaterCl:lemistry IIV.C1.RP 1581 3.1.179 I A;-+O+

CarB9R steel

{fAt}

C9Rtr91 iWR Class 1)

B9"'RElary Table 2.3.4-2-13 Seal Oil System Nonsafety-Related Components Affecting Safety-Related Systems Components SUbject to Aging Management Review Component Type Intended Function(s)1 Bolting Pressure boundary Filter housing Pressure boundary Heat e*sl:laRger (B9RRet)

Press...re B9...RElary Heat e*sl:laRger (sl:lell)

Press...re B9...RElary Heat exchanger (end covers)

Pressure boundary Heat exchanger (plates)

Pressure boundary

Attachment to GNRO-2012/00093 Page 10 of 15 Table 3.4.2-2-13 Seal Oil System Nonsafety-Related Components Affecting Safety-Related Systems Summary of Aging Management Evaluation Table 3.4.2-2-13: Seal Oil System, Nonsafety-Related Components Affecting Safety-Related Systems Component Intended Aging Effect Aging Management NUREG-1801 Material Environment Requiring Table 1 Item Notes Type Function Management Programs Item Weat PFeSSI::lr:e

.6,iF iRd99F

~xteFRal Sl::IrlaGes eXGRaRgeF CaF99R steel b9ss 9' mateFial VIII.H.S 29 3.4.1 34 A

991::1RdaFy (ext)

M9Rit9FiRg WateF CRemistl)'

Weat Pr:eSS1::1Fe Tr:eated wateF C9RtF91 CI9sed eXGRaRgeF CaF99R steel b9ss 9f mateFial VIII.E.S 23 3.4.1 25 G

991::1RdaFy

~

TFeated WateF (99RRet)

~

Weat PFeSSI::IFe A"

iRd99F

~xteFRal Sl::IrlaGes eXGRaRgeF CaF99R steel rolF b9ss 9' mateFial VIIIH.S 29 3.4.1 34 A

991::1RdaFy (ext)

M9Rit9FiRg

~

Weat PFeSSI::IFe eXGRaRgeF CaF99R steel bl::lge 9il (iRt) b9SS 9' mateFial Oil ARalysis VIII.A.SP 29 3.4.1 40

~

991::1RdaFy fsRem Heat Pressure Air - indoor External Surfaces exchanger boundary Carbon steel

[ext]

Loss of material Monitoring VIII.H.S-29 3.4.1-34 A

(end cover)

Heat Pressure exchanger boundary Carbon steel Lube oil (int)

Loss of material Oil Analysis VIII.A.SP-91 3.4.1-40 C,402 lend cover)

Heat Water Chemistry Pressure Treated water Control - Closed exchanger boundary Carbon steel

[int]

Loss of material Treated Water VIII.E.S-23 3.4.1-25 C

(end cover)

Svstems Heat Pressure Stainless Air - indoor exchanger boundary steel

[ext]

None None VIII.I.SP-12 3.4.1-58 Q

(Dlates)

Attachment to GNRO-2012/00093 Page 11 of 15 h"able 3.4.2-2-13: Seal Oil System, Nonsafety-Related Components Affecting Safety-Related Systems Component Intended Aging Effect Aging Management NUREG-1801 Material Environment Requiring Table 1 Item Notes Type Function Management Programs Item Heat Pressure Stainless exchanger boundary steel Lube oil (int)

Loss of material Oil Analysis VIII.G.SP-79 3.4.1-44 C,402 7DiateS\\

Heat Water Chemistry Pressure Stainless Treated water Control - Closed exchanger boundary steel

[int]

Loss of material Treated Water VIII.E.S-25 3.4.1-26 C

(plates)

Systems Carben steel Pump casing Pressure Gray cast Lube oil (int)

Loss of material Oil Analysis VIlI.A.SP-91 3.4.1-40 C,402 boundary iron Carben steel Pump casing Pressure Gray cast Air-indoor Loss of material External Surfaces VIII.H.S-29 3.4.1-34 A

boundary iron (ext)

Monitoring

Attachment to GNRO-2012/00093 Page 12 of 15 Table 2.3.3-19-19 Plant Service Water System Nonsafety-Related Components Affecting Safety-Related Systems Components SUbject to Aging Management Review Component Type Intended Function1 Bolting Pressure boundary Ejector Pressure boundary Flow element Pressure boundary Piping Pressure boundary Pump Pressure Boundary Sight glass Pressure Boundary Strainer housing Pressure boundary Tank Pressure boundary Thermowell Pressure boundary Tubing Pressure boundary Valve body Pressure boundary

Attachment to GNRO-2012/00093 Page 13 of 15 Table 3.3.2-19-19 Plant Service Water System Nonsafety-Related Components Affecting Safety-Related Systems Summary of Aging Management Evaluation Table 3.3.2-19-19:

Plant Service Water System [10 CFR 54.4(a)(2)]

Component Intended Aging Effect Aging NUREG-Table 1 Type Function Material Environment Requiring Management 1801 Item Item Notes Management Program Piping Pressure Stainless steel Condensation Loss of material External Surfaces G

Monitoring boundary (ext)

Piping Pressure Stainless steel Raw water (int)

Loss of material Service Water VII.C1.A-54 3.3.1-40

~

boundary Integrity Pump casing Pressure Stainless steel Raw water (int)

Loss of material Service Water VII.C1.A-54 3.3.1-40

~

boundary Integrity Pump casing Pressure Stainless steel Condensation Loss of material External Surfaces G

boundary (ext)

Monitoring Sight glass Pressure Stainless steel Raw water (int)

Loss of material Service Water VII.C1.A-54 3.3.1-40

~

boundary Integritv Sight glass Pressure Stainless steel Condensation Loss of material External Surfaces G

boundary (ext)

Monitoring Change in Internal Surfaces Pressure in Miscellaneous Sight glass Plastic Raw water (int) material E

boundary Piping and Ducting properties Components Pressure Condensation Change in External Surfaces Sight glass Plastic material E

boundary (ext)

Monitoring properties Tank Pressure Carbon steel Raw water (int)

Loss of material Service Water VII.C1.AP-183 3.3.1-38

~

boundary Integrity

Attachment to GNRO-2012/00093 Page 14 of 15 Table 3.3.2-19-19:

Plant Service Water System [10 CFR 54.4(a)(2)]

Component.

Intended Aging Effect Aging NUREG-Table 1 Type Function Material Environment Requiring Management 1801 Item Item Notes Management Program Tank Pressure Carbon steel Condensation Loss of material External Surfaces VII.I.A-81 3.3.1-78 A

boundary (ext)

Monitoring Valve body Pressure Stainless steel Condensation Loss of material External Surfaces G

boundarv (ext)

Monitoring Valve body Pressure Stainless steel Raw water (int)

Loss of material Service Water VII.C1.A-54 3.3.1-40 A

boundary Integrity

Attachment to GNRO-2012/00093 Page 15 of 15 Section 2.3.4.2 Condensate Cleanup The purpose of the condensate cleanup system (system code N22) is to maintain the required purity of feedwater flowing to the reactor. Normally, demineralizers are in operation processing full condensate flow. The condensate cleanup system consists of eight units of deep-bed-type demineralizers (with two units as spares) that operate in parallel, and thFss pFsooat filtsFs (with ons unit as spam) a condensate full flow filtration system used for startup. The system also includes the associated piping, ultrasonic resin cleaner, the advanced resin cleaning subsystem, and all necessary valves, instrumentation and controls.

Table 3.4.2-2-4 Condensate Cleanup System Nonsafety-Related Components Affecting Safety-Related Systems Summary of Aging Management Evaluation Table 3.4.2-2-4:

Condensate Cleanup System, Nonsafety-Related Components Affecting Safety-Related Systems Component Intended Aging Effect Aging NUREG-Table 1 Type Function Material Environment Requiring Management 1801 Item Item Notes Management Program Flow element Pressure Stainless steel Air - indoor (ext)

None None VIII.I.SP-12 3.4.1-58 A

boundary Flow element Pressure Stainless steel Treated water Loss of material Water Chemistry VIII.E.SP-87 3.4.1-16 A, 401 boundary (int)

Control - BWR