Byron StatIon aOCM Revision 7 Change Summary Matrix Page 1 of3 Administrative Changes -Determination A Technical Changes (Carbon-14)
-Determination B (old) (new) Determination Description of Change No. Rev. Rev. ldenllfler page page No. No. 1 Page Page A Q\anged K. value reference from Table 4-27 to Table 4-28 11.4-2 11.4-2 Sect Sect 4.2.1. 4.2.1.
1 1 Page Page A Changed and value references from Table 4-27 to Table 4-11.4-3 11.4-3 28 Sect Sect 4.2.1. 4.2.1. 2 2 Page Page A Changed M. value reference from Table 4-27 to Table 4-28 11.4-5 11.4-5 Sect Sect 4.2.2. 4.2.2. 1 1 4 Page Page A Changed N.value reference from Table 4-27 to Table 4-28 11.4-8 11.4-8 Sect Sect 4.2.2. 4.2.2. 2 2 5 Page Page A Changed value reference from Table 4-27 to Table 4-28 11.4-8 11.4-8 Sect Sect 4.2.2. 4.2.2.
3 3 Page Page B Inserted equation 4-12a to Calculate Carbon-14 Dose via 11.4-14 11.4-14 Vegetation Pathway to 11.4-15 t7 Page Page B Inserted equation 4-148 to Calculate C&rbon*14 Dose via MHk 11.4-16 11.4-17 Pathway Page Page B Inserted Equation 4-168 to Calculate C&rbon-14 Dose via Meat 11.4-17 11.4-19 Pathway Page Page B Inserted C&rbon-14 Into Table 4-7, Ground Plane Dose Factors 11.4-24 11.4-26 10 Page Page B Inserted C&rbon-14lnto Table 4-9, Adult Inhalation Dose Factors 11.4-29 11.4-31 11 Page Page B Inserted Catbon-14 into Table 4-10, Teen Inhalation Dose 11.4-31 11.4-33 Factors Byron StatIon OOCM Revlalon 7 Change Summary Matrix Page 2 013 Administrative Changes -Determination A Technical Changes (Carbon-14)
-Determination B 12 Page Page Inserted C8rb0n-14 into Table 4-11. Child Inhalation Dose 11.4-33 11.4-35 B Factors 13 Page Page Inserted C&rbon*14 i1to Table 4-12. Infant Inhalation Dose 11.4-35 11.4-37 B Factors 14 Page Page Inserted C&rbc)n.141nto Table 4-13. Adult Vegetation Dose 11.4-37 11.4-39 B Factors 15 Page Page Inserted C&rbon*14 into Table 4*14. Teen Vegetation Dose 11.4-39 11.4-41 B Fac:tora 16 Page Page 11.4-41 11.4-43 B Inserted C&rbc)n.14 into Table 4-15. Child Vegetation Dose Factors 17 Page Page 11.4-43 11.4-45 B Inserted Carbon*14 Into Table 4-18. Adult Grass-COW*MUk Dose Factors 18 Page Page 11.4-45 11.4-47 B Inserted Carbon-14 Into Table 4-17. Teen Graas-Cow-Milk Dose Factors 19 Page Page 11.4-47 11.4-49 B Inserted Carbon-14lnto Table 4-18. Child Grass-COW-Milk Dose Factors rzo Page Page B Inserted C8rb0n-14 into Tabte 4-19. Infant Grass-Cow-Mllk Dose 11.4-49 11.4-51 Factors 21 Page Page B Inserted C&rbon-14 Into Table 4-20. Adult Grass-Goat*Milk Dose 11.4-51 11.4-53 Factors 22 Page Page B Inserted Carbon-14 into Table 4-21. Teen Grass-Goat-Milk Dose 11.4-53 11.4-55 Factors Page Page B Inserted Carbon-14 Into Table 4-22. Child Grass-Goat-Mllk Dose 11.4-55 11.4-57 Factors 124 Page Page B Inserted C8rb0n*14 Into Table 4-23. Infant Grass-Goat-MUk Dose 11.4-57 11.4-59 Factors and Corrected TItle 125 Page Page Inserted C8rb0n-14 Into Table 4-24 Adult Grass-Cow-Meat Dose 11.4-59 11.4-81 B Factors and Corrected Table Number 126 Page Page B ln8ened Catbon-14lnto Table 4-25. Teen Grass-COW-Meat Dose 11.4-81 11.4-63 Factors and Corrected Table Nwnber 127 Page Page B Inserted C&rbon*14 Into Table 4*28. Child Graaa-Cow-Meat Dose 11.4-63 11.4-85 Factors and Corrected Table Number 128 Page Page A Changed mislabeled Table 4-23. Adult Grass-Cow-Meat Dose 11.4-59 11.4-61 Factors. to Table 4-24 to to 11.4-60 11.4-62 Page Page A Changed mislabeled Table 4-24. Teen Grass-COW-Meat Dose 11.4-81 11.4-63 Factors. to Table 4-25 to to 11.4-62 11.4-84 Byron Station ODCM Revision 7 Change Summary Matrix Page 3013 Administrative Changes -Determination A Technical Changes (Carbon-14)
-Determination B Page Page A Changed mislabeled Table 4-25. Child Grass-Cow-Meat Dose 11.4-63 11.4-65 Factors. to Table 4-26 to to 11.4-64 11.4-68 31 Page Page A Changed mislabeled Table 4-26. Byron Station Characteristics.
11.4-65 11.4-67 to Table 4-27 32 Page Page A Changed mislabeled Table 4-27. Dose Factors for Noble Gases. 11.4-66 11.4-66 to Table 4-28 33 Page Page A Removed duplicated infonnation (distance.
direction and sedor) 116-2 II 6-2 that Is also contained In Table 6-2 To To Added "upstream control" identifier to BY -34 sediment sample Page Page location II 6-9 116-8 Changed Milk sample location BY-18 to BV-1&-1 to reflect new Table Table location 6-1 6-1 Page Page A Changed location on map of BY*201-1 to accurately reflect real 116-12 116-13 location FIgure Figure Changed location on map of BY *2a1*2. 208-2. 1. 209-4. 6-3 6-3 215-1, 215-4 to reflect relocation of these TLOs 3s Page Page A Moved BV*34 sediment location to accurately reflect the current 116-13 116-14 location (upstream of plant dlsc:t1arge)
Figure Figure Changed Milk sample location BY-18 to BV-1&-1 to reflect new 6-4 6-4 location 36 Page Page A Updated distance.
direction and sector designations based on 116-15 II 6-15 higher accuracy measurements with current technology To To Changed table to reflect new vent stack release point Page Page coordinates 116-17 II 6-19 Changed latitude and longitude conventions Table Table Added column for distance in miles 6-2 6-2 Added column for compass direction Changed sector location of BY-22 from F to G Changed sector location of BY*34 from M to P Changed Milk sample location BV-18 to BY* 1 &-1 to reflect new location Changed locations of BV-207*2.
208-2. 209-1. 209-4.215-1.
215-4 to reflect relocation of these TLDs