UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION III
2443 WARRENVILLE ROAD, SUITE 210
LISLE, IL 60532-4352
July 27, 2012
Mr. Barry Allen
Site Vice President
FirstEnergy Nuclear Operating Company
Davis-Besse Nuclear Power Station
5501 North State Route 2, Mail Stop A-DB-3080
Oak Harbor, OH 43449-9760
SUBJECT: DAVIS-BESSE NUCLEAR POWER STATION - NOTIFICATION OF A
TEMPORARY INSTRUCTION 2515/177 INSPECTION AND A REQUEST FOR
INFORMATION 05000346/2012005 (DRS)
Dear Mr. Allen:
On October 15, 2012, the U. S. Nuclear Regulatory Commission (NRC) will begin the on-site
portion of the Gas Accumulation Management in Emergency Core Cooling, Decay Heat
Removal, and Containment Spray Systems Temporary Instruction at your Davis-Besse Nuclear
Power Station. This inspection will be performed in accordance with the NRC Temporary
Instruction (TI) 2515/177.
In order to minimize the inspections impact on the site and to ensure a productive inspection,
we have enclosed a request for information needed for the inspection. The documents have
been divided into three groups.
- The first group lists information necessary for our initial inspection scoping activities.
This information should be available to the inspector no later than August 20, 2012.
By August 31, 2012, the inspector will communicate the initial selected samples.
- The second group is needed to support our in-office preparation activities. This set of
documents should be available at the Regional Office no later than September 28, 2012.
This information should be separated by information request number, especially if provided
electronically (e.g., folder with the information request number). During the in-office
preparation activities, the inspectors may identify additional information needed to support
the inspection. The lead inspector will provide a list of the additional information needed
during the week of October 1, 2012.
- The last group includes the additional information above as well as plant specific reference
material. This information should be available to the inspectors on October 15, 2012. It is
also requested that corrective action documents and/or questions developed during the
inspection be provided to the inspector as the documents are generated.
It is important that these documents be as complete as possible, in order to minimize the
number of documents requested during the preparation week or during the on-site inspection.
If no activities were accomplished associated with a specific request, then provide a statement
indicating that the request is not applicable.
Mr. Allen -2-
The inspector for this inspection is Mr. Larry J. Jones Jr. Please send the information
electronically to the following e-mail address larry.jones@nrc.gov. A hard-copy with the
required information is also an acceptable option.
This letter does not contain new or amended information collection requirements subject to the
Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection
requirements were approved by the Office of Management and Budget, control number 3150-
0011. The NRC may not conduct or sponsor, and a person is not required to respond to, a
request for information or an information collection requirement unless the requesting document
displays a currently valid Office of Management and Budget control number.
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its
enclosure will be available electronically for public inspection in the NRC Public Document
Room or from the Publicly Available Records Systems (PARS) component of NRCs document
system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-
rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA by A. Dunlop Acting For/
Ann Marie Stone, Chief
Engineering Branch 2
Division of Reactor Safety
Docket No. 50-346
License No. NPF-3
Enclosure: TEMPORARY INSTRUCTION 2515/177 INSPECTION AND A REQUEST FOR
INFORMATION
cc w/encl: Distribution via ListServ'
TEMPORARY INSTRUCTION 2515/177 REQUEST FOR INFORMATION
Inspection Report: 05000346/2012005(DRS)
Inspection Dates: October 15 - 19, 2012, and October 29 - November 2, 2010
Inspection Procedure: Temporary Instruction (TI) 2515/177, Management of Gas
Accumulation in Emergency Core Cooling, Decay Heat Removal,
and Containment Spray Systems
Lead Inspector: Larry J. Jones Jr.
(630) 829-9864
larry.jones@nrc.gov
Team Member: Andrew Dunlop
(630) 829-9726
andrew.dunlop@nrc.gov
I. Information Requested by August 20, 2012
1. Copy of the station response to Generic Letter (GL) 2008-01 and any supplemental
reports.
2. Copies of all the requests for additional information (RAIs) and the associated
responses.
3. List of corrective action program documents (with a short description) associated
with GL 2008-01, voids in piping, gas intrusion events, and pressure transients for
the previous three years that affected the subject systems (i.e., emergency core
cooling, decay heat removal, and containment spray systems).
4. List of the suction piping sections identified as susceptible to gas accumulation (the
list should identify the corresponding system).
5. List of the discharge piping sections identified as susceptible to gas accumulation
(the list should identify the corresponding system).
6. List of changes (with a short description and tracking number) to the Updated
Safety Analysis Report (USAR), Technical Specifications, Technical Specification
Bases, and Technical Requirement Manual associated with the resolution of
7. List of calculations associated with GL 2008-01 (with a short description of the
calculation and the change), including calculations that have been changed or
created in response to GL 2008-01.
1 Enclosure
TEMPORARY INSTRUCTION 2515/177 REQUEST FOR INFORMATION
II. Information Requested By September 28, 2012
1. Copies of program documents and procedures developed to implement the
resolution of GL 2008-01.
2. Copies of the selected corrective action program documents.
3. Copies of the selected licensing and design basis document changes.
4. Copies of the selected calculations.
5. List of commitments (with a description) created in response to GL 2008-01.
6. List of actions completed in response to GL 2008-01.
7. List of outstanding actions that will be completed in response to GL 2008-01 and the
completion schedule (include the documents that are tracking their completion such
as work orders or corrective action documents).
8. Copies of all the corrective actions identified in the nine-month response and
supplemental reports.
9. List (with a short description) of gas intrusion mechanisms that apply to the plant
and the affected system locations (e.g., identify the source, conditions, and
expected void locations).
10. Design basis documents of the subject systems.
11. Design basis documents of keep-full systems of the subject systems.
12. Copies of the construction code pages of the subject systems that discuss
waterhammer or flow-induced dynamic loading. Also, include the associated
Design Specification pages.
13. Provide the following description for the pumps of the subject systems: (1) flowrate
at best efficiency point; (2) maximum and minimum flowrate during accident
conditions and shutdown cooling; (3) number of pump stages; (4) if a pump is multi-
stage, indicate if the shaft is stiff or flexible (include the basis for this determination);
(5) pump head required to meet operability requirements; and (6) un-degraded
pump head.
14. (As applicable) Copies of self-assessments associated with the implementation of
the GL 2008-01 program and the associated corrective action program documents
(include the attachments, if any).
15. Copies of corrective action program implementing procedures.
16. Copies of the operability determination procedures.
2 Enclosure
TEMPORARY INSTRUCTION 2515/177 REQUEST FOR INFORMATION
17. Electronic copies of piping and instrumentation diagrams (P&IDs) of the subject
systems.
18. If available, electronic copies of the current Technical Specifications, Technical
Specifications Basis, Updated Safety Analysis Report, and Technical Report
Manual.
III. Information to be Provided to the Inspector on October 15, 2012. Please Provide
Hard Copies (e.g., paper records) of the Following Documents.
1. Copies of surveillance procedures associated with the resolution of GL 2008-01 and
the results of the last two surveillances for the subject systems.
2. Copies of the modification packages for hardware modifications as part of the
resolution of GL 2008-01.
3. Copies of procedures use for detecting and determining void volumes.
4. Copies of procedures use for filling and venting.
5. Copies of surveillance procedures that establish flow at the subject systems (e.g.,
surveillances where the pumps are operated)
6. Subject systems walkdown work documents associated with the resolution of
GL 2008-01 and the results of these walkdowns.
7. Copies of the engineering evaluations performed for all identified voids.
8. Provide a list of all piping locations that are currently voided and their associated
evaluation.
9. Copies of trends of periodic gas accumulation monitoring results (e.g., venting,
UTs).
10. Copy of the design change review checklist.
11. Copies of training documents that ensure that personnel are aware of gas-related
concerns. Include the scheduled or attendance list of training that was already
conducted.
12. Copy of the void transport analysis.
13. Basis for the void acceptance criteria (e.g., calculation). If applicable, provide the
justification for any deviation from the void acceptance criteria established by the
Office of Nuclear Reactor Regulations (NRR).
14. Basis for horizontal pipe acceptance criteria (e.g., calculation).
3 Enclosure
TEMPORARY INSTRUCTION 2515/177 REQUEST FOR INFORMATION
15. If applicable, provide a list of inaccessible locations where plant walkdowns of the
subject systems have not been completed. Include an explanation of why each
area is considered inaccessible.
16. Hardcopies of isometric drawings of the subject systems (11X17) or similar size is
preferred if legible).
17. Hardcopies of piping and instrumentation diagrams (P&IDs) of the subject systems
(11X17) or similar size is preferred if legible).
The inspector for this inspection is Mr. Larry J. Jones Jr. If there are questions about the
material requested, or the inspection, please call Mr. Larry J. Jones Jr. at (630) 829-6894.
4 Enclosure
Mr. Allen -2-
The inspector for this inspection is Mr. Larry J. Jones Jr. Please send the information
electronically to the following e-mail address larry.jones@nrc.gov. A hard-copy with the
required information is also an acceptable option.
This letter does not contain new or amended information collection requirements subject to the
Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection
requirements were approved by the Office of Management and Budget, control number 3150-
0011. The NRC may not conduct or sponsor, and a person is not required to respond to, a
request for information or an information collection requirement unless the requesting document
displays a currently valid Office of Management and Budget control number.
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its
enclosure will be available electronically for public inspection in the NRC Public Document
Room or from the Publicly Available Records Systems (PARS) component of NRCs document
system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-
rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA by A. Dunlop Acting For/
Ann Marie Stone, Chief
Engineering Branch 2
Division of Reactor Safety
Docket No. 50-346
License No. NPF-3
Enclosure: TEMPORARY INSTRUCTION 2515/177 INSPECTION AND A REQUEST FOR
INFORMATION
cc w/encl: Distribution via ListServ'
DISTRIBUTION:
See next page
DOCUMENT NAME: G:\DRSIII\DRS\Work in Progress\Ltr 072712 Davis Besse TI 177 RFI LJJ.docx
Publicly Available Non-Publicly Available Sensitive Non-Sensitive
To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy
OFFICE RIII RIII
NAME LJones:ls ADunlop ADunlop for AMStone
DATE 07/27/12 07/27/12 07/27/12
OFFICIAL RECORD COPY
Letter to Mr. Barry Allen from Ms. Ann Marie Stone dated July 27, 2012.
SUBJECT: DAVIS-BESSE NUCLEAR POWER STATION - NOTIFICATION OF A
TEMPORARY INSTRUCTION 2515/177 INSPECTION AND A REQUEST FOR
INFORMATION 05000346/2012005 (DRS)
DISTRIBUTION:
RidsNrrDorlLpl3-2 Resource
RidsNrrPMDavisBesse Resource
RidsNrrDirsIrib Resource
Chuck Casto
Cynthia Pederson
DRPIII
DRSIII
Patricia Buckley