O SE H
4 University of Michigan Occupational Safety & Environmental Health Campus Safety Services Building Occupational Safety &
1239 Kipke Drive, Ann Arbor, MI 48109-1010 Environmental Health Phone: 734 647-1143
- Fax: 734 763-1185 July 13, 2012 Document Control Desk U.S. Nuclear' Regulatory Commission Two White Flint North 11545 Rockville Pike (Mail Code: 03H8)
Rockville, Maryland 20852-2738 RE:
Ford Nuclear Reactor - Technical Specification Amendment Request Decommissioning Plan - Revised Section 4.0 (Final Status Survey)
Docket 50-2 1 License R-28 Licensing Branch:
The University of Michigan (U-M) is requesting an amendment to the Ford Nuclear Reactor (FNR) Decommissioning Plan that was submitted to the Commission in a correspondence dated January 10, 2006. Appendix E ('Derived DCGL for C-14 in Subsurface Soil') in Section 4.0
('Final Status Survey') of the Decommissioning Plan has been revised in accordance with recent discussions with the Nuclear Regulatory Commission (NRC) - Decommissioning Branch staff (Ted Smith / FNR Project Manager).
A copy of the most recently revised Appendix E of the Final Status Survey (FSS) Plan is enclosed with this correspondence and the specific changes to the FSS Plan are noted below.
Changes Made to the Final Status Survey Plan - (Revised Appendix E / Derived DCGL for C-14 in Subsurface Soil at the FNR)
Enclosed is the revised version of the C-14 DCGL subsurface soil development document (Appendix E in FSS Plan), incorporating minor changes in response to questions and comments from the NRC in May / June 2012.
The changes in Appendix E of the FSS Plan include the following:
1.0 Revised cover page to Appendix E indicating the date of revision (June 28, 2012) 2.0 Indication of the RESRAD User's Manual under 'Comments; in Table 3, Page 49 as the source of inhalation rates (m3/y), and 3.0 Addition of the 'Industrial Worker Al' scenario in Appendix A of Appendix E in the FSS
- Plan.
2 RESRAD COMPUTER RUNS In addition to the revisions to Appendix E of the FSS Plan, please find enclosed the RESRAD Computer Runs for the Derived DCGL for C-14 in Subsurface Soil at the FNR facility (Appendix A in Appendix E / Version 6.5). As noted in #3 above, this computer run includes the addition of the 'Industrial Worker Al' scenario.
N Thank you for your time, effort, and consideration with respect to this FNR license (R-28) amendment. Please do not hesitate to contact me at OSEH / Radiation Safety Service [(734) 647-2251] should you have any questions or comments regarding the revised Final Status Survey Plan. We look forward to your approval so we can initiate the final status survey of the FNR facility.
Sincerely, Mark L. Driscoll Director / Radiation Safety Officer Radiation Safety Service / OSEH MLD/TGA/mId NRCFNRR-28AmendmentD&DFSSPlanSec4AppEO71312.doc cc:
Terry Alexander, Executive Director, OCS Mark Banaszak Holl, Associate Vice President, OVPR Robert Blackburn, Manager, Laboratory Operations, MMPP Theodore Smith, FNR Project Manager, NRC Headquarters (Mailstop T-8F5)
Jeremy Tapp, Health Physicist, NRC Region III FNR Decommissioning File
June 2012 Appendix E Derived Concentration Guideline Level for C-14 in Subsurface Soil at the Former Ford Nuclear Reactor Site University of Michigan Ann Arbor, Michigan Prepared by DeNuke Contracting Services, Inc.
Oak Ridge, Tennessee Revision A June 28, 2012 40
June 2012 Derived Concentration Guideline Levels for Subsurface Soil at the Former Ford Nuclear Reactor Site
1.0 INTRODUCTION
The Ford Nuclear Reactor (FNR) at the University of Michigan, in Ann Arbor, MI, is being decommissioned. The decommissioning activities are described in University of Michigan Decommissioning Plan for the Ford Nuclear Reactor; Chapter 4 of that Decommissioning Plan describes the Final Status Survey Plan for demonstrating that the decommissioning has been effective in satisfying Nuclear Regulatory Commission (NRC) criteria for termination of the license and to permit unrestricted future use of the facility. NRC Default Screening Values have been selected as radiological criteria for the building surfaces and surface soil. Sampling to date has indicated residual concentrations of radionuclides are typically within their respective Default Screening Values.
However, there is one small region of subsurface soil, containing concentrations of C-14, potentially slightly greater than the Default Screening Value for C-14 of 11.6 pCi/ g. This location is in the vicinity of the foundation drain around the perimeter of the FNR building. C-14 has not been identified at other locations in the FNR, and the source of this contaminant is not known. The volume of potentially contaminated subsurface soil is this location is estimated to be less than 50 m 3; for calculation purposes, 50 m3 was the assumed volume. This document describes the development of a Derived Concentration Guideline Limit (DCGL) for C-14 in subsurface soil associated with the FNR foundation drain.
DCGL calculations were based on a dose limit of 25 mrem/y for likely future land use scenarios.
Calculations were performed, based on deterministic analysis, for a time period out to 1000 years, using RESRAD, Version 6.5. The most restrictive DCGL for the various scenarios and time periods was selected for C-14 in the subsurface soil.
2.0 SCENARIO DESCRIPTION It is assumed that the University will have institutional control of this site for a period of 100 years, and in the immediate future, after deconammissioning is completed, that the former FNR facility will be used by the University primarily as offices, classrooms, and laboratories. After the institutional control period ends, the land could be rezoned for industrial, recreational, or residential use. Three scenarios (A-industrial worker on site, B-building occupancy for educational purposes, and C-off-site resident) were considered for current use conditions. The contamination is limited to a small volume (<50 m 3) of subsurface soil, located beneath approximately 5 m of clean cover and about 4 m above the saturated zone; contaminated soil is at least 500 m from the nearest off-site residential area; and surrounding off-site areas are urban and subsistence farming is not currently a potential land use. The off-site resident scenario was therefore not considered of potential significance and was not evaluated further. Another two scenarios (D-subsistence farming and E-recreational use) were evaluated for the period following institutional control.
Scenario A (current on-site industrial worker) assumes that certain outdoor work activities will result in removing clean overburden, exposing the contaminated soil. Workers would perform maintenance and construction operations on the surface of the exposed contaminated soil for a period of 3 months (500 hr/yr or 0.0571 yr), after which the clean overburden would be replaced. The worker would also be exposed annually for 3 months (0.0571 yr) during renovation activities inside the building. The 41
June 2012 worker will not ingest contaminated water, plant, fish, meat, or milk obtained from the site. Direct exposure is to an individual, immediately on the other side of the building wall/floor from the contaminated soil, and the calculation assumed uncovered soil. Because radiological decay would result in slightly lower doses for the industrial use scenario after 100 years of institutional control than for the same scenario during the first 100 years, that scenario was not evaluated beyond the 100 year time period.
Scenario B (building occupant) assumes presence in the building 2000 hr/yr (0.2283 yr). The occupant would be potentially exposed to external radiation from covered contaminated soil. Exposure to airborne contamination and internal radiation from ingestion of water, plants, meat, milk, and fish, impacted by the contaminated soil are not considered potential exposure pathways.
Scenario D (future subsistence farmer) assumes residential use of the site after the institutional control period. The resident farmer would be exposed to direct radiation and to internal radiation from inhalation of contaminated dust, and ingestion of water, plants, meat, milk, and fish and incidental ingestion of soil. All water used by the resident farmer for drinking, irrigation, and household use would be drawn from a deep well, adjacent to the former FNR facility. Nearby surface water sources and shallow wells are not considered adequate to sustain a subsistence farmer. Two versions of this scenario were considered-one with the clean soil cover in place and one with the clean sol cover removed (intrusion) thus exposing the contaminated soil. Because the intrusion scenario would not occur until after the 100 year institutional control period, intrusion was assumed to occur at the 100 year point and the 1, 3, 10 and 30 year times were considered starting at that point in time. Because of the relatively long half life of C-14 no radiological decay was considered to have occurred prior to discontinuation of institutional control.
Scenario E (future recreational use) assumes that an individual camps on the site two weeks per year and engages in recreational activities, such as biking and hiking. During that time drinking water would be drawn from a surface water pond that captures run-off from the site and fish would be obtained from that pond. The recreationist does not ingest plants, meat, or milk obtained from the site.
3.0 PATHWAYS AND KEY PARAMETERS Potential radiation doses resulting from multiple exposure pathways are considered in this analysis for all exposure scenarios. These pathways include:
(1) direct exposure to external radiation from contaminated soil material, (2) internal radiation from inhalation of contaminated dust, (3) internal radiation from incidental ingestion of on-site soil, (4) internal radiation from ingestion of plant foods grown in the contaminated area and irrigated with an on-site water source, 42
June 2012 (5) internal radiation from ingestion of meat from livestock raised on site and fed with fodder grown in the contaminated area and irrigated with water drawn from an on-site well or pond (the water ingested by livestock is also drawn from an on-site water source),
(6) internal radiation from ingestion of milk from livestock raised onsite and fed with fodder grown in the contaminated area and irrigated with on-site well water or pond water (the water ingested by milk cows is also drawn from on-site water source),
(7) internal radiation from ingestion of fish from a pond located down nearby the contaminated
- area, (8) internal radiation from drinking water from a deep well, (9) internal radiation from drinking water from an on-site water source (pond water),
(10) internal radiation from ingestion of plant foods grown off-site and irrigated with contaminated well water, (11) internal radiation from ingestion of meat from livestock raised off-site and fed with fodder grown off-site but irrigated with contaminated well water (the water ingested by livestock is also drawn from a deep well, (12) internal radiation from ingestion of milk from livestock raised off-site and fed with fodder grown off-site but irrigated with contaminated well water (the water ingested by milk cow is also drawn from the well), and (13) ingestion of fish from an off-site surface water source.
Table 1 summarizes the applicable exposure pathways for all scenarios and Table 2 lists the key parameters for the applicable exposure pathways. With exception of dimensions, cover depth, exposure time, and a few scenario-specific parameters, RESRAD Default values have been used for these calculations. Table 3 contains a list of parameters. Although they may be listed in Table 3, some parameters are not used in the calculations because the applicable pathway has been suppressed.
43
June 2012 Table 1 Summary of Applicable Exposure Pathways for Different Scenarios Considered for Former Ford Nuclear Reactor Facility Exposure Pathway Applicable Pathways Current Use Future Use Scenario Aa Scenario Bb Scenario DC Scenario Ed Direct external gamma exposure Yes Yes Yes Yes Inhalation of dust Yes*
No Yes Yes Ingestion of soil Yes*
No Yes Yes Ingestion of plant foods grown onsite No No Yes No Ingestion of meat from livestock raised No No Yes No onsite Ingestion of milk from livestock raised No No Yes No onsite Ingestion of fish from an on-site pond No No Yes Yes Ingestion of water from a down gradient No No Yes No deep well Ingestion of water from a nearby surface No No Yes Yes water source Ingestion of plant foods grown offsite No No No No Ingestion of meat from livestock raised No No No No offsite Ingestion of milk from livestock raised No No No No offsite Ingestion of fish from surface water No No No No source offsite a Industrial Worker b Building Occupant C Subsistence Farmer d Recreationist
- Phase Al (cover removed) only.
Table 2 List of Key Parameters for Applicable Exposure Pathways Exposure Pathway Key Parameters Direct external gamma exposure Time fraction spent on-site and external gamma shielding factor Inhalation of dust Inhalation rate, time fraction spent on-site, mass loading for inhalation, and indoor dust filtration factor Ingestion of soil Soil ingestion rate and time spent on-site Ingestion of plant foods grown on-site Plant transfer factor, plant ingestion rate, surface water dilution factor, and release rate from the source Ingestion of meat from livestock raised Plant transfer factor, meat transfer factor, meat ingestion rate, water dilution on-site factor, and release rate from the source Ingestion of milk from livestock raised Plant transfer factor, milk transfer factor, milk ingestion rate, surface water on-site dilution factor, and release rate from the source Ingestion of fish from a nearby pond Fish bioaccumulation factor, aquatic food contaminated fraction, surface water dilution factor, and release rate from the source 44
June 2012 Ingestion of water from a Water ingestion rate, infiltration rate, Kd values (or leach rate) for downgradient well contaminants, and hydrogeological parameters for the site Ingestion of water from a nearby Water ingestion rate, surface water dilution factor, and release rate from the surface water source source Ingestion of plant foods grown off-site Plant transfer factor, plant ingestion rate, surface water dilution factor, and release rate from the source Ingestion of meat from livestock raised Plant transfer factor, meat transfer factor, meat ingestion rate, surface water off-site dilution factor, and release rate from the source Ingestion of milk from livestock raised Plant transfer factor, milk transfer factor, milk ingestion rate, surface water off-site dilution factor, and release rate from the source Ingestion of fish from surface water Fish bioaccumulation factor, aquatic food contaminated fraction, surface source off-site v'ater dilution factor, and release rate from the source 45
June 2012 Table 3. Parameter Values Used for Deterministic Analysis of Different Scenarios Current Use Scenarios Future Use Scenarios Input Parameters A: Industrial B: Building D: Subsistence E: Recreationist Comments worker Occupant farmer Title Title Scenario Scenario Scenario Scenario Scenario Definition dependent dependent dependent dependent ICRP-60 methodology based DCFs Dose factor library ICRP-60 ICRP-60 ICRP-60 ICRP-60 (external from FGR-12 and internal from ICRP-72 and FRG-11 (C-14))
Cut-off Half Life (180 d or 30 d) 30 d 30 d 30 d 30 d RESRAD default Number of Points (32, 64, 128, 256, 512, 32 32 32 32 RESRAD default 1024)
Linear Spacing/Log Spacing Log Spacing Log Spacing Log Spacing Log Spacing RESRAD default Maximum No of Points for Dose 17 17
- 17.
17 RESRAD default Maximum No of Points for Risk 1
1 1
1 Use line draw character (yes/ no)
Yes yes yes yes RESRAD default Find peak pathway dose (yes/no)
Yes yes yes yes Save all files after each run (yes/no)
Yes yes yes yes Time integrated probabilistic risk No no no no Dose-to-source ratio (DSR) is calculated (yes/no)
Calculation Parameters Basic radiation dose limit (mrem/year) 25 25 25 25 Not used in DSR calculation Times for calculation (years) 0, 1, 3, 10, 30, 0,1, 3, 10, 30, 0, 3, 10, 30, 0100,300,1000 100, 300,1000 100, 300,1000 100, 300, 1000 0, 100, 300, 1000 Source Nuclide concentration (pCi/g) 1 1
1 1
Dose-source ratios calculated Transport Factors Distribution coefficient for zones Cont.; 1 Cont.; 1 Cont.; 1 Cont.; 1 (cm 3/g)
Unsat/; NA Unsat/; NA Unsat/; 1 Unsat/; 1 Number of unsaturated zones NA NA 1
1 RESRAD default Time since placement of material (y) 0 0
0 0
RESRAD default 46
June 2012 Current Use Scenarios Future Use Scenarios Input Parameters A: Industrial B: Building D: Subsistence E: Recreationist Comments worker Occupant farmer Groundwater concentration (pCi/L) 0 0
0 0
RESRAD default Leach rate (l/y) 0 0
0 0
RESRAD default Solubility limit (mol/L) 0 0
0 0
RESRAD default Use plant/soil ration (check box)
No No No No RESRAD default Transfer Factors Plant transfer factor (wet-plant weight concentration pCi/g / dry soil weight 5.5 5.5 5.5 5.5 RESRAD Default concentration pCi/g)
Meat transfer factor (concentration in 0.031 0.031 RESRAD Default meat pCi/g / rate of intake pCi/d) 0.031 0.031 Milk transfer factor (concentration in 0.012 0.012 0.012 0.012 RESRAD Default milk pCi/ L / rate of intake pCi/ d)
Fish transfer factor (concentration in fish 50,000 50,000 50,000 50,000 RESRAD Default pCi/Kg / concentration in water pCi/L)
Crustacea transfer factor (concentration in Crustacea pCi/Kg / concentration in 9100 9100 9100 9100 RESRAD Default water pCi/L)
Contaminated Zone Parameters Area of Contaminated Zone (M 2 )
50 50 50 50 Characterization survey results Thickness of Contaminated Zone (m) 1 1
1 1
Characterization survey results Length Parallel to Aquifer Flow (m) 100 100 100 100 RESRAD default Does the initial contamination penetrate No No No No RESRAD default the water table?
Cover and Contaminated Zone Hydrological Data Cover Depth (m)
A1;0 5
Al; 5
Characterization survey results A2; 5 A2; 5 Density of Cover Material (g/cm3)
Al; NA 1.5 Al; NA 1.5 RESRAD Default A2; 1.5 A2; 1.5 Cover Erosion Rate (m/y)
NA 0.001 NA 0
RESRAD Default 47
June 2012 Current Use Scenarios Future Use Scenarios A: Industrial B: Building D: Subsistence Input Parameters worker Occupant farmer E: Recreationist Comments Density of Primary Contaminated Zone 1.5 1.5 1.5 1.5 RESRAD Default (g/cm3)
Contaminated Zone Erosion Rate (m/y) 0.001 0.001 0.001 0.001 RESRAD Default Contaminated Zone Total Porosity 0.4 0.4 0.4 0.4 RESRAD Default Contaminated Zone Field Capacity 0.2 0.2 0.2 0.2 RESRAD default Contaminated Zone Hydraulic cond.
10 10 10 10 RESRAD Default (m/y)
Contaminated Zone b Parameter 5.3 5.3 5.3 5.3 RESRAD Default Humidity in Air (g/m 3)
NA NA NA NA Used only for H-3 Evapotranspiration Coefficient 0.5 0.5 0.5 0.5 RESRAD Default Wind Speed (m/s) 2.0 2.0 2.0 2.0 RESRAD Default Precipitation rate (m/y) 1.0 1.0 1.0 1.0 RESRAD Default Irrigation rate (m/y) 0.2 0.2 0.2 0.2 RESRAD Default Irrigation mode (Overhead/Ditch)
Overhead Overhead Overhead Overhead RESRAD default Runoff coefficient 0.2 0.2 0.2 0.2 RESRAD Default Watershed area for nearby stream or NA NA 1000000 1000000 RESRAD default pond (M 2)
Accuracy for water/soil computation NA NA 0.001 0.001 RESRAD default Saturated Zone Hydrological Data Density of saturated zone (g/cm 3)
NA NA 1.5 1.5 RESRAD Default Saturated zone effective porosity NA NA 0.2 0.2 RESRAD Default Saturated zone total porosity NA NA 0.4 0.4 RESRAD Default Saturated zone field capacity NA NA 0.2 0.2 RESRAD Default Saturated zone hydraulic conductivity NA NA 100 100 RESRAD Default (m/y)
Saturated zone b parameter NA NA 5.3 5.3 RESRAD Default Saturated zone hydraulic Gradient NA NA 0.02 0.02 RESRAD Default Water table drop rate (m/y)
NA NA 0.001 0.001 RESRAD default 48
June 2012 Current Use Scenarios Future Use Scenarios Input Parameters A: Industrial B: Building D: Subsistence E: Recreationist Comments worker Occupant farmer Well pump intake depth (m below water NA NA 10 10 RESRAD Default table)
Model for water transportation Non-(nondispersion / mass-balance)
NA NA dispersion Non-dispersion RESRAD default Well pumping rate (m3/y)
NA NA 250 250 RESRAD default Unsaturated zone parameters Thickness of unsaturated zone (in)
NA NA 4
4 RESRAD Default Density of unsaturated zone (g/cm3)
NA NA 1.5 1.5 RESRAD Default Unsaturated zone effective porosity NA NA 0.2 0.2 RESRAD Default Unsaturated zone total porosity NA NA 0.4 0.4 RESRAD Default Unsaturated zone field capacity NA NA 0.2 0.2 RESRAD default Unsaturated zone hydraulic NA NA 10 10 RESRAD Default conductivity (m/y)
Unsaturated zone b parameter NA NA 5.3 5.3 RESRAD Default Occupancy, Inhalation, and External Gamma Parameters Inhalation rate (m3/y) 11,400 NA 8400 14,000 Scenario-specific; RESRAD User's Manual Mass loading for inhalation (g/m 3) 1E-4 NA 1E-4 1E-4 RESRAD default Exposure duration (y) 25 30 30 30 Not used in DSR calculations Indoor dust filtration factor NA NA 0.4 0.4 RESRAD default External gamma shielding factorAl; A0 0.7 A1; 0 NA RESRAD default IndoortimefractionA2; 0.7 A2; 0.7 Indoor time fraction Al; 0.0571 0.2285 0.6833 0
Scenario-specific
_A2; 0.0571 Outdoorntime fraction A; 0.0571 0
0.0833 0.0384 Scenario-specific Shape of contaminated zone Circular circular circular circular Characterization survey results (circular/ noncircular)____________________________________
Ingestion Pathway Dietary Data Fruit, vegetable and grain consumption NA NA 160 NA RESRAD default 49
June 2012 Current Use Scenarios Future Use Scenarios Input Parameters A: Industrial B: Building D: Subsistence E: Recreationist Comments worker Occupant farmer (kg/y)
Leafy vegetable consumption (kg/y)
NA NA 14 NA RESRAD default Milk consumption (L/y)
NA NA 92 NA RESRAD default RESRAD default and scenario-specific Meat and poultry consumption (kg/y)
NA NA 63 NA for recreationa se for recreational use RESRAD default and scenario-specific Fish consumption (kg/y)
NA NA 5.4 NA frrcetoa s
for recreational use Other sea food consumption (kg/y)
NA NA 0.9 0
RESRAD default; Rec. scenario specific.
Soil ingestion (g/y)
Al; 36.5 NA 36.5 36.5 RESRAD default Soil
__ingestion_(g/y)_A2; 0
RESRAD default and scenario specific Drinking water intake (L/y)
NA NA 510 19.6 for Recreation se for Recreation use Drinking water contaminated fraction NA NA 1
1 RESRAD default and for offsite receptor scenario water is not contaminated Household water contaminated fraction NA NA NA NA RESRAD default Livestock water contaminated fraction NA NA 1
NA RESRAD default Irrigation water contaminated fraction NA NA 1
NA RESRAD default Aquatic food contaminated fraction NA NA 0.5 0.5 Distribution from NUREG/CR-6697 Plant food contaminated fraction NA NA
-1 NA Calculated by RESRAD from area factor Meat contaminated fraction NA NA
-1 NA Scenario specific Milk contaminated fraction NA NA
-1 NA Calculated by RESRAD from area factor Ingestion Pathway, Nondietary Data Livestock fodder intake for meat (kg/ d) NA NA 68 NA RESRAD default or scenario specific Livestock fodder intake for milk (kg/d) NA NA 55 NA RESRAD default Livestock water intake for meat (L/ d)
NA NA 50 NA Or scenario specific Livestock water intake for milk (L/d)
NA NA 160 NA RESRAD default Livestock intake of soil for meat (kg/d) NA NA 0.5 NA RESRAD default Livestock intake of soil for milk (kg/ d)
NA NA 0.5 NA RESRAD default Mass loading for foliar deposition NA NA 0.0001 NA RESRAD default (g/m3)
I I
I I
50
June 2012 Current Use Scenarios Future Use Scenarios Input Parameters A: Industrial B: Building D: Subsistence E: Recreationist Comments worker Occupant farmer Depth of soil mixing layer (m) 0.15 NA 0.15 NA RESRAD default Depth of roots (m)
NA NA 0.9 NA RESRAD default Drinking water fraction from NA NA 1
NA Scenario specific groundwater Source Household water fraction from NA NA NA NA Scenario specific groundwater Source RESRAD default for Resident Farmer Livestockwater fraction from and 0 for Recreational Use Scenario groundwater Source because surface water is used by livestock Irrigation water fraction from NA NA 1
NA RESRAD default groundwater Source Plant Factors Wet weight crop yield for non-leafy NA NA 0.7 NA RESRAD default vegetables (kg/m 2)
Length of growing season for non-leafy NA NA 0.17 NA RESRAD default vegetables (y)
Translocation factor for non-leafy NA NA 0.1 NA RESRAD default vegetables Weathering removal constant (1/y)
NA NA 20 NA Distribution from NUREG/CR-6697 Wet foliar interception fraction for non-NA NA 0.25 NA RESRAD default leafy vegetables Dry foliar interception fraction or non-NA NA 0.25 NA RESRAD default leafy vegetables Wet weight crop yield for leafy NA NA 1.5 NA RESRAD default vegetables (kg/m 2)
Length of growing season for leafy NA NA 0.25 NA RESRAD default vegetables (y)
Translocation factor for leafy vegetables NA NA 1
NA RESRAD default Wet foliar interception fraction for leafy NA NA 0.25 NA RESRAD default 51
June 2012 Current Use Scenarios Future Use Scenarios Input Parameters A: Industrial B: Building D: Subsistence E: Recreationist Comments worker Occupant farmer vegetables Dry foliar interception fraction for leafy NA NA 0.25 NA RESRAD default vegetables Wet weight crop yield for fodder NA NA 1.1 NA RESRAD default (kg/m2) 1.1_NA RESRADdefault Length of growing season for fodder (y) NA NA 0.08 NA RESRAD default Translocation factor for fodder NA NA 1
NA RESRAD default Wet foliar interception fraction for NA NA 0.25 NA RESRAD default fodder NANA 0.25 NA RESRADdefault Dry foliar interception fraction for NA NA 0.25 NA RESRAD default fodder NANA 0.25_
NA RESRADdefault Storage-Times-Before-Use Data Storage time for fruits, non-leafy 14 NA 14 NA RESRAD default vegetables and grain (d)
Storage time for leafy vegetables (d) 1 NA 1
NA RESRAD default Storage time for milk (d) 1 NA 1
NA RESRAD default RESRAD default for Resident Farmer Storage time for meat (d) 20 NA 20 NA and scenario specific for Recreational Use RESRAD default and scenario specific Storage time for fish (d) 7 NA 7
0 frRcetoa s
for Recreational use Storage time for crustacea and mollusks 70 RESRAD default and scenario specific (d) for Recreational use RESRAD default for Resident Farmer Storage time for well water (d) 3 NA 1
NA and not required for Recreational Use RESRAD default for Resident Farmer Storage tim e for surface w ater (d) 1 NA 1
NA a d 0 for RereationalmUs and 0 for Recreational Use RESRAD default for Resident Farmer Storage time for livestock fodder (d) 45 NA 45 NA and scenario specific for Recreational Use 52
June 2012 Current Use Scenarios Future Use Scenarios Input Parameters A: Industrial B: Building D: Subsistence E: Recreationist Comments worker Occupant farmer Radon Data NA NA NA NA Radon not a potential contaminant Carbon-14 Data C-12 concentration in local water, g/cm 3 2E-5 2E-5 2E-5 2E-5 RESRAD default C-12 concentration in contaminated soil, 0.03 0.03 0.03 0.03 RESRAD default g/g Fraction of vegetation carbon absorbed 0.02 0.02 0.02 0.02 RESRAD default from soil Fraction of vegetation carbon absorbed 0.98 0.98 0.98 0.98 RESRAD default from air Thickness of evasion layer of C-14 in 0.3 0.3 0.3 0.3 RESRAD default soil, m C-14 evasion flux rate from soil, sec-1 7E-7 7E-7 7E-7 7E-7 RESRAD default C-12 evasion flux rate from soil, sec-1 1E-10 1E-10 1E-10 IE-10 RESRAD default Grain fraction in beef cattle feed 0.8 0.8 0.8 0.8 RESRAD default Grain fraction in milk cow feed 0.2 0.2 0.2 0.2 RESRAD default NA indicates not applicable to scenario.
53
June 2012 3.0 RESULTS OF CALCULATIONS Printouts of computer runs for the exposure scenarios are attached as an appendix to this report. Dose estimates for I pCi/g (at t = 0) of C-14 soil contamination are summarized in Table 5. Values less than 1E-02 mrem/pCi/g would result in DCGL values greater than 2500 p/ Ci/ g; that value is therefore used as a lower dose bound.
Table 4 Annual Dose from 1 pCi/g of C-14 for Evaluated Scenarios Time (yr)
Dose (mrem)
Industrial Building Subsistence Recreationist Worker*
Occupant Farmer 5m Om Cover Cover 0
<1E-02
<1E-02 NA NA NA 1
<1E-02
<1E-02 NA NA NA 3
<1E-02
<1E-02 NA NA NA 10
<1E-02
<1E-02 NA NA NA 30
<1E-02
<1E-02 NA NA NA 100 NA NA
<1E-02
<1E-02
<1E-02 300 NA NA
<1E-02
<1E-02
<1E-02 1000 NA NA
<1E-02
<1E-02
<1E-02
- Sum of dose from indoor and outdoor activities Estimated annual dosed from all of the scenarios evaluated were less than 1E-02 mrem/y for a 1 pCi/g concentration of C-14. The concentration of C-14 in subsurface soil would therefore have to exceed 2500 pCi/g to deliver an annual dose of 25 mrem, based on any of these four scenarios.. That concentration is therefore selected as the subsurface soil DCGL for residual C-14 at the FNR site. Criteria for other subsurface soil concentrations of other radionuclides, associated with the former FNR operations, will be the conservative Default Screening Values for surface soil.
54
APPENDIX A Printouts of RESRAD Computer Runs 16
- RESRAD, Version 6.5 T-s Limit = 30 days 05/04/2012 12:28 Page Summary :JUMC14_rOa_5m File
- C:\\RESPADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_ROAOM.RAD
(-I-r cý )
Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
Site-Specific Parameter Summary..........................
Summary of Pathway Selections.............................
Contaminated Zone and Total Dose Summary.................
Total Dose Components Time D.O O0E+00.....................................
Time = 1.000E+00....................................
Time = 3.O O E+00.....................................
Time = 1.000E+01....................................
Time = 3.OOOE+01....................................
Time = 1 ODDE+02....................................
Time = 3.DOO E+02.....................................
Time = 1.000E+03.
Dose/Source Ratios Summed Over All Pathways..............
Single Radionuclide Soil Guidelines......................
Dose Per Nuclide Summed Over All Pathways................
Soil Concentration Per Nuclide............................
2 3
7 8
9 10 12 13 14 15 16 17 17 18 18 0--4 J-Iýs Al
RESRAD, Version 6.5 T1 Limit = 30 days 05/04/2012 12:28 Page 2
Summary : UMC14_r~a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_ROAOM.RAD Dose Conversion Factor (and Related) Parameter Summary
-Dose Library:
FGR 12 & FGR ii Menu Parameter A-I DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-1 C-14 (Source: FGR 12)
B-i Dose conversion factors for inhalation, mrem/pCi:
B-I C-14(p)
(Class: ORGANIC)
B-1 C-14(g)
(Class: C02)
D-1 Dose conversion factors for ingestion, mrrem/pCi:
D-I C-14 Current j Base value#
Case*
1.345E-05 1.345E-05 2.090E-06 2.090E-06 2.350E-08 2.35GB-CS I2-090E-06 2.090E-06 5.500E+00 5.500E+00 3.100E-02 I3.10OC-02 1.200E-02 1.200E-02 I5.OOCE+C4 5.OCCE+/-C4 9,100E+03 9.100E4-03 Parameter Name DCFI(
1)
DCF2(
1)
CI4GInhDCF DCF3(
1)
RTF(
1,l)
RTF(
1,2)
RTF(
1,3)
BIOFAC(
1I BIOFAC (
I, D-34 D-34 D-34 D-34 D-5 D-5 D-5 Food C-14 C-14 C-14 transfer factors:
plant/soil concentration ratio, dimensionless beef/livestock-intake ratio, (pCi/kg)/(pCi/d) milk/livestock-intake ratio, (pCi/L)/(pCi/d)
Bioaccumulation factors, fresh water, L/kg:
, fish C714
, crustacea and mollusks
,1)
,2)
- For DCFl(xxx) only, factors are for infinite depth & area.
See
- Base Case means Default.Lib w/o Associate Nuclide contributions.
ETFG table in Ground Pathway of Detailed Report.
- RESRAD, Version 6.5 T11 Limit = 30 days 05/04/2012 12:28 Page 3
Summary : UMC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\IWCl4_ROAOM.RAD Site-Specific Parameter Summary Menu Parameter I
R011 R011 R011 R011 R011 R011 R011 R011 R011 R011 R011 R011 R011 R011 R011 R012 R012 R013 R013 R013 R013 1(013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R013 R014 R014 R014 k014 R014 R014 R014 R014 R014 R014 R014 Area of contaminated zone (m**2)
Thickness of contaminated zone (m)
Fraction of contamination that is submerged Length parallel to aquifer flow (m)
Basic radiation dose limit (mrem/yr)
Time since placement of material (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Times for calculations (yr)
Initial principal radionuclide (pCi/g):
C-14 Concentration in groundwater (pCi/L) :
C-14 Cover depth (m)
Density of cover material (g/cm**3)
Cover depth erosion rate (m/yr)
Density of contaminated zone (g/cm**3)
Contaminated zone erosion rate (m/yr)
Contaminated zone total porosity Contaminated zone field capacity Contaminated zone hydraulic conductivity (m/yr)
Contaminated zone b parameter.
Average annual wind speed (m/sec)
Humidity in air (g/m**3)
Evapotranspiration coefficient Precipitation (m/yr)
Irrigation )m/yr)
Irrigation mode Runoff coefficient Watershed area for nearby stream or pond (m**2)
Accuracy for water/soil computations Density of saturated zone (g/cm**3)
Saturated zone total porosity Saturated zone effective porosity Saturated zone field capacity Saturated zone hydraulic conductivity (m/yr)
Saturated zone hydraulic gradient Saturated zone b parameter Water table drop rate (m/yr)
Well pump intake depth (m below'water table)
Model: Nondispersion (ND) or Mass-Balance (MB)
Well pumping rate (m**3/yr)
-I-User Input I
- 5. 00OE+01 1.OOOE+00 0.OOOE+00 I not used j 2.500E+01 0.OOOE+00 1.000E+00 3.OOOE+00 1.000E+01 3.000E+01 1.OOOE+02 3.00OE+02 1.000E+03 not used not used 1.000E+00 not used 0.000E+00 not used not used 1.500E+00 1.000E-03 4.OOOE-01 2.000E-01 1.000E+01 5.300E+00 2.000E+00 not used 5.00DE-01 1.000E+00 2.000E-01 overhead 2.000E-01 not used not used not used not used not used not used not used not used not used not used not used not used not used Default 1.000E+04 2.000E+00 0.000E+00
.1.0005+02 3.000E+01 0.000E+00 1.OOOE+00 3.000E+00 1.000E+01 3.000E+01 1.000+E02 3.000E+02 1.000E+03 0.000E+00 0.000E+00 0.00 0E+00 0.000E+00 0.000E+00 1.500E+00 1.000E-03 1.500E+00 1.000E-03 4.000E-01 2.000E-01 1.000E+01 5.300E+00 2.000E+00 8.000E+00 5.000E-01 1.000E+00 2.000E-01 overhead 2.000E-01 1.000E+06 1.000E-03 1.500E+00 4.000E-01 2.000E-01 2.0005-01 1.000E+02 2.000E-02 5.300E+00 1.000E-03 1.000E+01 ND.
2.500E+02 Used by RESRAD (If different from user input)
Parameter Name AREA 4 THICKO SUBMFRACT LCZPAQ BRDL TI T( 2)
T( 3)
T( 4)
T( 5)
T(
6)
T(
7)
T(
8)
T(
9)
T(10)
Sl(1)
Wl(
1)
COVERO DENSCV VCV L DENSCZ VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA EPS DENSAQ TPSZ EPSZ FCSZ HCSZ HGWT BSZ VWT DWIBWT MODEL UW
- RESRAD, Version 6.5 T1 Limit = 30 days 05/04/2012 12:28 Page 4
Summary : UMC14_r0a_5m File
": C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCI4_ROA OM.RAD Site-Specific Parameter Summary (continued)
Menu Parameter R015 R015 R015 R015 R015 R015 R015 R015 R016 R016 R016 R016 R016 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R0a7 R017 R017 R017 R017 R017 R017 R017 Number Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
of unsaturated zone strata zone 1, thickness (m) zone 1, soil density (g/cm**3) zone 1, total porosity zone 1, effective porosity zone 1, field capacity zone 1, soil-specific b parameter zone 1, hydraulic conductivity (m Distribution coefficients for C-14 Contaminated zone (cm**3/g)
Unsaturated zone 1 (cm**3/g)
Saturated zone (cm**3/g)
Leach rate (/yr)
Solubility constant Inhalation rate (m**3/yr)
Mass loading for inhalation (g/m**3)
Exposure duration Shielding factor, inhalation Shielding factor, external gamma Fraction of time spent indoors Fraction of time spent outdoors (on site Shape factor flag, external gamma Radii of shape factor array (used if FS Outer annular radius. (m),
ring 1:
User Input not used not used not used not used not used not used not used a/yr) not used 1.000E+0(
not used not used 0.000E+0(
0.000E+0(
1.140E+04 1.000E-04 2.500E+0]
4.000E-0O 7.DOOE-0]
5.710E-02 5.710E-0D 1.000E+0[
not used not used not used not used not used not used not used not used not used not used not used Inot used i
2 0
Default 1
4.0OOE+00 1.500E+00 4.OOOE--01 2.OOOE-01 2.OOOE-01
- 5. 300E+00 1.OO0E+01 0.0OOE+00 0.000E+00 0.0O0E+00 0.000E+00 0.OO0E+00 8.400E+03 1, 00 E-04 3.D0E+01 4.0OE-01 7.OOE-01 5 00. E-01 2.500E-01 1 0.0E+00 5.000E+01 7.071E+01 0.OOOE+00 O. OOOE+O0 0.0OOE+00 0.OO0E+D 00
- 0. 0O0E+00 0.OO0E+00 0.000E+00 0.000DE+00
- 0. 000E+00 0.000E+00 2.746E-01 not used
>0 shows circular AREA.
Used by RESRAD I
Parameter (If different from user input)
Name
-NS H(l)
-- DENSUZ(1)
TPUZ(1)
EPUZ(1)
FCUZ(1)
BUZ(1)
HCUZ(1)
DCNUCC(
DCNUCU(
DCNUCS(
ALEACH(
SOLUBK(
INHALR MLINH ED SHF3 SHFI FIND FOTD FS 1) 1)
1) 1)
Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer annular annular annular annular annular annular annular annular annular annular annular radius radius radius radius radius radius radius radius radius radius radius (n),
(in),
(in),
(in),
(in),
(In)
(m),
(in),
(i),
(in),
ring ring ring ring ring ring ring ring ring ring ring 2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
RADSHAPE) 1)
RADSHAPE(
2)
RADSHAPE) 3)
RADSHAPE) 4)
RAD SHAPE) 5)
HADSHAPE) 6)
RADSHAPE( 7)
RADSHAPE) 8)
RADSHAPE) 9)
RADSHAPE (10)
HADSHAPE(ll)
RADSHAPE (12)
RESRAD, Version 6.5 Th Limit = 30 days 05/04/2012 12:28 Page 5
Summary : UM C14_r~a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWC14_RDADM.RAD Site-Specific Parameter Summary (continued)
Parameter R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R018 R018 R018 R018 R018 R018 R018 R018 R018 RD18 R018 R018 R018 R018 R018 R018 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R19B R19B R19B R19B R19B R19B 1-I.
Fractions Ring 1
Ring 2
Ring 3
Ring 4
Ring 5
Ring 6
Ring 7
Ring 8
Ring 9
Ring 10 Ring 11 Ring 12 of annular areas within AREA:
Fruits, vegetables and grain consumption (kg/yr)
Leafy vegetable consumption (kg/yr)
Milk consumption (L/yr)
Meat and poultry consumption (kg/yr)
Fish consumption (kg/yr)
Other seafood consumption (kg/yr)
Soil ingestion rate (g/yr)
Drinking water intake (L/yr)
Contamination fraction of drinking water Contamination fraction of household water Contamination fraction of livestock water Contamination fraction of irrigation water Contamination fraction of aquatic food Contamination fraction of plant food Contamination fraction of meat Contamination fraction of milk Livestock fodder intake for meat (kg/day)
Livestock fodder intake for milk (kg/day)
Livestock water intake for meat (L/day)
Livestock water intake for milk (L/day)
Livestock soil Intake (kg/day)
Mass loading for foliar deposition (g/m**3)
Depth of soil mixing layer (m)
Depth of roots (m)
Drinking water fraction from ground water Household water fraction from ground water Livestock water fraction from ground water Irrigation fraction from ground water Wet weight crop yield for Non-Leafy (kg/m**2)
Wet weight crop yield for Leafy (kg/m**2)
Wet weight crop yield for Fodder (kg/m**2)
Growing Season for Non-Leafy (years)
Growing Season for Leafy' (years)
Growing Season for Fodder (years)
User Input not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used 0.000E+00 not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used 1.500E-01 not used not used not used not used not used not used not used not used not used not used not used Default I 100OE+00 2.732E-01 0.000E+00 S0.000E+00 0.D0E+00 0.00 E+00 0.0005+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 1.600E+02 1.400E+01 9.200E+01 6.3005+01 5 5.4005+00 9 9.000-01 3.650E+01 5.100E+02 1.000E+00 I
2.000E+00 1.000E+00 1.0005+00 5 5.000E-01 1-I
-i I-I 6.800E+01 5 5.500E+01 5 5.000E+01 1.600F+02 5.000E-01 1.000E-04 1.500E-01 9.0D0E-01 S1.DO0DE+D0 1.000E+00 1.000E+00 1.000E+00 7.000E-01 1.500E+00 1.100E+00 1.700E-01 I-2.500E-01 I 8.000E-02
+
Used by RESRAD (If different from user inpu Parameter t)
Name FRACA(
1)
FRACA(
2)
FRACA(
3)
FRACA(
4)
FRACA(
5)
FRACA(
6)
FRACA(
7)
FRACA(
8 )
FRACA(
9)
FRACA(10)
FRACA(1I)
FRACA(12)
DIET(l)
DIET(2)
DIET(3)
DIET1(4)
DIET(5)
DIET(6)
SOIL DWI FDW FHHW FLW FIRW FR9 FPLANT FMEAT FMILK LFI5 LFI6 LWI5 LWI6 LSI MLFD DM DROOT FGWDW FGWHH FGWLW FGWIR Yv(1)
YV(2)
YV(3)
TE(1)
TE(2)
TE(3)
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:28 Page 6
Summary : UMC14_r0a_5m File
- C:\\RESPADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWC14_R0AOM.RAD Site-Specific Parameter Summary (continued)
Menu Parameter R19B R19B R19B R19B R19B R19B R19B R1 9B
£14 C14 C14 C14
£14 C14
£14 C14 C14 STOP S TOR STOP STOR STOP STOP STOP STOR STOP STOP R021 R021 R021 R021 R021 RD21 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 Translocation Factor for Non-Leafy Translocation Factor for Leafy Translocation Factor for Fodder Dry Foliar Interception Fraction for Non-Leafy Dry Foliar Interception Fraction for Leafy Dry Foliar Interception Fraction for Fodder Wet Foliar Interception Fraction for Non-Leafy Wet Foliar Interception Fraction for Leafy Wet Foliar Interception Fraction for Fodder Weathering Removal Constant for Vegetation C-12 concentration in water (g/cm**3)
C-12 concentration in contaminated soil (g/g)
Fraction of vegetation carbon from soil Fraction of vegetation carbon from air C-14 evasion layer thickness in soil (m)
C-14 evasion flux rate from soil (1/sec)
C-12 evasion flux rate from soil (1/sec)
Fraction of grain in beef cattle feed Fraction of grain in milk cow feed Storage times of contaminated foodstuffs (days)
Fruits, non-leafy vegetables, and grain Leafy vegetables Milk Meat and poultry Fish Crustacea and mollusks Well water Surface water Livestock fodder Thickness of building foundation (m)
Bulk density of building foundation (g/cm**3)
Total porosity of the cover material Total porosity of the building foundation Volumetric water content of thecover material Volumetric water content of the foundation Diffusion coefficient for radon gas (m/sec):
in cover material in foundation material in contaminated zone soil Radon vertical dimension of mixing (m)
Average building air exchange rate (1/hr)
Height of the building (room)
(m)
Building interior area factor Building depth below ground surface (m)
Emanating power of Rn-222 gas Emanating power of Rn-220 gas nUo not not not not not not not not not not 2.00 3.00 2.00 9.80 3.01 7.00 1.00 8.00 2.00 1.40 1.00 1.00 2.00 7.00 7.00 1.00 1.00 4.50 not not not not not not not not not not not not not not not not ser nput' Default used 1.000E-01 used 1.OOOE+00 used 1.OOOE+00 used 2.500E-01 used 2.500E-01 used 2.500E-01 used 2.500E-01 used 2.500E-01 used 2.500E-01 used 2.OOOE+01 0OE-05 2.0OOE-05 O0E-02 3.000E-02 0OE-02 2.0OOE-02 0OE-01 9.800E-01 OOE-01 3.OOOE-01 OOE-07 7.OO0E-07 OOE-10 1.OO0E-10 oE-01l 8.00O0-01 0DE-01 2,000E-01 0OE+01 1.400E+01 00E+00 1.OOOE+00 00E+00 1.OO0E+00 00E+01 2.OOE+01 00E+00 7,000E+00 O0E+00 7.000E+00 JOE+00 1.000E+00 00E+00 1.000E+00 0OE+01 4.500E+01 used 1.500E-01 used 2.400E+00 used 4.ODE-01 used 1.000E-01 used 5.DOE-02 used 3.OOOE-02
'used 2.0OOE-06 used 3.OOOE-07 used 2.000E-06 used 2.OOOE+00 used 5.000E-01 used 2.500E+00 used 0.OOOE+00 used 1-1.000E+00 used 2.500E-01 used 1.500E-01 32 Used by RESRAD (If different from user input)
Par
'N TIV(
TIV(
TIV(
RDRY RDRY RDRY RWET RWET RWET WLAM C12W C12C CSOI CAIR DMC EVSN REVS AVFG AVFG STOR STOR STOR STOR STOR STOR STOR STOR STOR FLOO DENS TPCV TPFL PH20 PH20 DIFC DIFF DIFC HMIX REXG HRM FAI DMFL EMAN.
EMAN.
NPTS ameter ame 1) 2)
3)
(1)
(2)
(3)
(1)
(2)
(3)
TR Z
L N
4 5
_T (1)
_T (2)
_T (3)
T (4)
T(5)
_T (6)
T (7)
_T(8)
T (9)
R1 FL CV FL V
L Z
A(1)
A (2)
TITL Number of graphical time points
- RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:28 Page 7
Summary : UMC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_R0A _OM.RAD Site-Specific Parameter Summary (continued)
Menu I User i
Input I
Used by RESRAD I
Parameter Default I (If different from user input) I Name Parameter t
t TITL j Maximum number of integration points for dose 17 LYMAX TITL Maximum number of integration points for risk 257 KYMAX Summary of Pathway Selections Pathway User Selection 1 --
external gamma active 2 --
inhalation (w/o radon) active 3 --
plant ingestion suppressed 4 --
meat ingestion suppressed 5 --
milk ingestion suppressed 6 --
aquatic foods suppressed 7 --
drinking water suppressed 8 --
soil ingestion active 9 --
radon suppressed Find peak pathway doses active
RESRAD, Version 6.5 Ti Limit =30 days 05/04/2012 12:28 Page 8
Sumnmary : CMC14 rOa 5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCI4 ROA 0M.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area:
Thickness:
Cover Depth:
50.00 square meters 1.00 meters 0.00 meters C-14 1.0O0E+00 Total Dose TDOSE(t),
mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t)
= Fraction of Basic Dose Limit Received at Time (t) t (years):
0.000E+00 1.000E+00 3.OODE+00 1.000E+01 3.000E+01 1.000E+02 3.ODOE+02 1.000E+03 TDOSE(t):
1.379E-06 1.363E-09 1.280E-15 0.000E+00 0.000E+00 0.ODOE+00 0.000E+00 0.000E+00 M(t) :
5.516E-08 5,452E-11 5.120E-17 D.DD0E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Maximum TDOSE(t):
1.379E-06 mrem/yr at t = 0.000E+00 years
RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:28 Page 9
Summary :UM _C14_rOa_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_R0A_0M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 1.449E-07 0.1051 Total 1.449E-07 0.1051 Inhalation Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
1.234E-06 0.8949 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 1.234E-06 0.8949 0.000E+00 0.0000 0.000E+00 0.0000 0.0OOE+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.000E+00 0.0C O.O00E+00.
O.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000.
0.000E+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 1.379E-06 1.OC 1.379E-06 1.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T;1 Limit = 30 days 05/04/2012 12:28 Page 10 Summary : UM C14_rOa_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_R0AOM.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 1.433E-10 0.1051 Total 1.433E-10 0.1051 Inhalation mrem/yr fract.
1.220E-09 0.8949 1.220E-09 0.8949 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
O.O00E+00 0.0000 O.O00E+00 0.0000 O.O00E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.0008+00 0.0000 Soil mrem/yr frac 0.000E+00 O.OC 0.OOOE+00 O.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000+E00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 1.363E-09 1.OC 1.363E-09 1,OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:28 Page 11 Summary UM C14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCI4_ROA_0M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOOE+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 1.345E-160.1051 Total 1.345E-16 0.1051 Inhalation mrem/yr fract.
1.145E-15 0.8949 1.145E-15 0.8949 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Plant Meat mrem/yr fract.
mrem/yr fract.
O.O00E+00 0.0000 O.O00E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.0OOE+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC 0.OOOE+00 O.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOOE+00 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.OOOE+00 0.0000 Total 0.OOOE+00 0.0000 Fish mrem/yr fract.
0.OOOE+00 0.0000 O.OOOE+00 0.0000 Radon mrem/yr fract."
O.OOOE+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Meat mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 1.280E-15 l.OC 1.280E-15 1.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 Tl.s Limit = 30 days 05/04/2012 12:28 Page 12 Summary UMC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_RCAOM.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Inhalation Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.0C Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fradt.
C-14 0.OOOE+00 0M0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:28 Page 13 Summary :UMC14_r0a_5m File.
C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCI4_R0AOM.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Inhalation Radon Plant Meat mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.000E+00 O.OC 0.000E+00 0.0C Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.OOE+00 0.0000 Total 0.OOOE+00 0.0000 Fish mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 O.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0,0C 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T's Limit = 30 days 05/04/2012 12:28 Page 14 Summary : UM Cl4rOea_5m File
- C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\Cl4\\IWCI4 ROA 0M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OO0E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OO0E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr. frac 0.000E+00 0.OC 0.000E+00 0.0C Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOE+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Total 0.OOOE+00 0.0000 0.OOOE+00 0-.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0.OC 0.O00E+00 D.OC
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 T,ý Limit = 30 days 05/04/2012 12:28 Page 15 Sunsary UM C14_r~a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWC14_RoAOM.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t
= 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.o000E+00 0.0000 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.O0OE+00 0.0000 Plant Meat mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000
-Milk mrem/yr fract.
O.OOOE+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC O.OOOE+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t 3.OOOE+02 years Water Dependent Pathways Water Fish Radio-Nuclide C-14 Total mrem/yr
- fract, 0.000E+00 0.0000 0.OOOE+00 0.0000 "mrem/yr fract.
0.OOOE+00 0.0000 0.O0OE+00 0.0000 Radon Plant mrem/yr fract.
mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Meat mrem/yr fract.
0.OOOE+00.0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 All Pathways mrema/yr frac 0.OOOE+00 Oýoc 0.OOOE+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 Týi Limit = 30 days 05/04/2012 12:28 Page 16 Summary :UMC14_rOa_5m File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCI4 ROA OM.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0,0000 Total 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0O000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.0C Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.OOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.0OOE+00 0.0000 Radio-Nuclide C-14 Total All Pathways mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.DC
- Sum of all water independent and dependent pathways,
RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:28 Page 17 Summary :
MC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_ROAOM.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)
(i)
(j)
Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 C-14 C-14 1.000E+00 1.379E-06 1.363E-09 1.28DE-15 6.718E-37 0.000E+00 0.000E+00 0.000E+00 0.000E+00 The DSR includes contributions from associated (half-life s 30 days) daughters.
Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i)(
t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 C-14 1.813E+07 1.834E+10
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- At specific activity limit Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 0.000E+00 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)
(i)
(pCi/g)
(years)
(pCi/g)
(pCi/g)
C-14 1.000E+00 0.000E+00 1.379E-06 1.813E+07 1,379E-06 1.813E+07
RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:28 Page 18 Summary UM C14_rOa_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_R0A_0M.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
DOSE(j,t),
mrem/yr (j)
(i) t= 0.OOOE+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 C-14 C-14 1.000E+00 1.379E-06 1.363E-09 1.280E-15 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
S(j,t), pCi/g (j)
(i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.OOOE+03 C-14 C-14 1.000E+00 1.000E+00 9.905E-04 9.335E-10 4.967E-31 0.000E+00 0.000E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
RESCALC.EXE execution time =
132.18 seconds
RESRAD, Version 6.5 T'. Limit = 30 days 05/04/2012 12:39 Page Summary UM C14_r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_RDA_5M.RAD Table of Contents Part I:
Mixture Sums *and Single Radionuclide Guidelines C
T-rz )
Dose Conversion Factor (and Related) Parameter Summary...
Site-Specific Parameter Summary..........................
Summary of Pathway Selections.............................
Contaminated Zone and Total Dose Summary.................
Total Dose Components.
Time = 0.OOOE+00.
Tim e = 1.000E+00 Tim e = 3.OOOE+00.
Time = 1.OOOE+01....................................
Time = 3.000E+01....................................
Time = 1.OOOE+02.
Tim e = 3.000E+02....................................
Time = 1.000E+03.
Dose/Source Ratios Summed Over All Pathways..............
Single Radionuclide Soil Guidelines......................
Dose PerNuclide Summed Over All Pathways................
Soil Concentration Per Nuclide............................
2 3
7 8
9 10 11 12 13 14 15 16 17 17 18 18 c,. e~~ 2 /
RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:39 Page 2
Summary UM C14 rOa 5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCI4_ROA_5M.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 12 & FGR 11 Menu Parameter A-I A-i B-I B-1 B-i DCF's for external ground radiation, (mrem/yr)/(pCi/g)
C-14 (Source: FGR 12)
Dose conversion factors for inhalation, mrem/pCi:
C-14(p)
(Class: ORGANIC)
C-14(g)
(Class: C02)
Dose conversion factors for ingestion, mrem/pCi:
C-14 Current Value#
1.345E-05 2.090E-06 2.350E-08 1.2.090E-06 I 5o500E+00 3.100E-02 1.200E-02 5.OOOE+04 9.100E+03 Base Parameter Case*
Name 1.345E-05 DCF(
.1) 2.090E-06 DCF2(
1) 2.350E-08 CI4GInhDCF 2.090E-06 DCF3(
1) 5.500E+00 RTF(
1,I) 3.100E-02 RTF(
1,2) 1.200E-02 RTF(
1,3) 5.000E+04 BIOFAC(
1, 9.100E+03 BIOFAC(
1, D-34 D-34 D-34 D-34 D-5 D-5 D-5 Food C-14 C-14 C-14 transfer factors:
plant/soil concentration ratio, dimensionless beef/livestock-intake ratio, (pCi/kg)/(pCi/d) milk/livestock-intake ratio, (pCi/L)/(pCi/d)
Bioaccumulation factors, fresh water, L/kg:
, fish C-14
, crustacea and mollusks 1) 2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See
- Base Case means Default.Lib w/o Associate Nuclide contributions.
ETFG table in Ground Pathway of Detailed Report.
- RESRAD, Version 6.5 TV Limit = 30 days 05/04/2012 12:39 Page 3
Summary UMC14_r0a_Sm File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_ROA_5M.RAD Site-Specific Parameter Summary User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input)'
Name R011 Area of contaminated zone (m**2) 5.OO0E+01 1.000E+04 AREA R011 Thickness of contaminated zone (m) 1.000E+00 2.0OOE+00 THICKO R011 Fraction of contamination that is submerged 0.000E+00 0.000E+00 SUBMFRACT R011 Length parallel to aquifer flow (m) not used 1.OOOE+02 LCZPAQ R011 Basic radiation dose limit (mrem/yr) j 2.500E+01 3.OOOE+01 BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 TI R011 Times for calculations (yr) 1.0OOE+00 1.000E+00
[ T( 2)
R011 Times for calculations (yr) 3.000E+00 3.OOOE+00 T( 3)
R01i" Times for calculations (yr) 1.000E+01 1.000E+01 T( 4)
R011 Times for calculations (yr) 3.O0OE+01 3.000E+01 T(5)
R011 Times for calculations (yr) 1.000E+02 1.OOOE+02 T( 6)
R011 Times for calculations (yr) 3.OOOE+02 3.000E+02 T(
7)
ROl1 Times for calculations (yr) 1.000E+03 I.000E+03 T(
9)
R011 Times for calculations (yr) not used O.OOOE+00 T(
9)
R011 Times for calculations (yr) not used O.OOOE+00 T(10)
I I
.I R012 Initial principal radionuclide (pCi/g):
C-14 1.OOOE+00 0.000E+00 SI(1)
R012 Concentration in groundwater (pCi/L):
C-14 not used 0.000E+00 Wl(
1)
R013 Cover depth (m) 5.000E+00 0.000E+00 COVERD R013 Density of cover material (g/cm**3) 1.500E+00 1.500E+00 DENSCV R013 Cover depth erosion rate (m/yr) 1.000E-03 1.0005-03 VCV R013 Density of contaminated zone (g/cm**3) 1.500E+00 1,500E+00 DENSCZ R013 Contaminated zone erosion rate (m/yr) 1.000E-03 1.000E-03 VCZ R013 Contaminated zone total porosity 4.000E-01 4.000E-01 TPCZ R013 Contaminated zone field capacity 2.000E-01 2.000E-01 FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 1.000E+01 1.000E+01 HCCZ R013 Contaminated zone b parameter 5.300E+00 5.300E+00 BCZ R013 Average annual wind speed (m/sec) 2.000E+00 2.000E+00 WIND R013 Humidity in air (g/m**3) not used 8.000E+00 HUMID R013 Evapotranspiration coefficient 5.OOE-01 5.000E-01 EVAPTR R013 Precipitation (m/yr) 1.000E+00 1.000E+00 PRECIP R013 Irrigation (m/yr) 2.000E-01 2.000E-01 RI R013 Irrigation mode overhead overhead IDTCH R013 Runoff coefficient 2.000E-01 2.000E-01 RUNOFF R013 Watershed area for nearby stream or pond (m**2) not used 1.000E+06 WAREA R013 Accuracy for water/soil computations not used 1.000E-03 EPS R014 Density of saturated zone (g/cm**3) not used 1.500E+00 DENSAQ R014 Saturated zone total porosity not used 4.000E-01 TPSZ R014 Saturated zone effective porosity not used 2.000E-01 EPSZ R014 Saturated zone field capacity not used 2.OOOE-01 FCSZ R014 Saturated zone hydraulic conductivity (m/yr) not used 1.000E+02 HCSZ R014 Saturated zone hydraulic gradient not used 2.OOOE-02 HGWT R014 Saturated zone b parameter not used 5.300E+00 BSZ R014 Water table drop rate (m/yr) not used 1.000E-03 VWT R014 Well pump intake depth (m below water table) not used 1.000E+01 DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) not used ND MODEL R014 Well pumping rate (m**3/yr) not used 2.500E+02 UW
RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:39 Page 4
Summary :UMC14_ra_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWC14 RCA 5M.RAD Site-Specific Parameter Summary (continued)
Menu R015 R015 R015 R015 R015 R015 R015 R015 R016 R016 R016 R016 R016 R016 R017 R017 R017 R017 R017 R017 R017 R017 R017 Parameter Number of unsaturated zone strata Unsat. zone 1, thickness (m)
Unsat. zone 1, soil density (g/cm**3)
Unsat. zone 1, total porosity Unsat. zone 1, effective porosity Unsat. zone 1, field capacity Unsat. zone 1, soil-specific b parameter Unsat. zone 1, hydraulic conductivity (m/yr)
Distribution coefficients for C-14 Contaminated zone (cm**3/g)
Unsaturated zone 1 (cm**3/g)
Saturated zone (cm**3/g)
Leach rate (/yr)
Solubility constant Inhalation rate (m**3/yr)
Mass loading for inhalation (g/m**3)
Exposure duration Shielding factor, inhalation Shielding factor, external gamma Fraction of time spent indoors Fraction of time spent outdoors (on site)
Shape factor flag, external gamma Radii of shape factor array (used if FS = -1):
User Input not used not used not used not used not used not used not used not used 1.000E+00 not used not used 0.00OE+00
- 0. OOOE+00 1,140E+04 1.OOOE-04 2.500E+01 4.OOOE-01 7.OOOE-01 5.710E-02 5.710E-02 1.OOOE+00 1
"4 2
2 50 0
0 0
0
]
]
Default 4.OOOE+00 1.500E+00 O*QOE-01 2.000E-01 C..OOE-01 5.300E+00 000E+01 DO.OE+00
.OOOE#00
'.000E+00
.OOOE+00 OOOE+00
.400E+03
.OOOE-04
.OOOE+01
.000E-01 O.0O0E-01
.000E-01
.500E-01
.OOOE+00 Used by RESRAD (If different from user input)
NS H(1)
DENSUZ (i)
TPUZ (1)
EPUZ (1)
FCUZ (1)
BUZ (1)
HCUZ (1)
Parameter Name 8
1 3
4 7
5 2
1 2.746E-01 not used
>0 shows circular AREA.
DCNUCC(
DCNUCU(
DCNUCS(
ALEACH(
SOLUBK(
INHALR MLINH ED SHF3 SHFI FIND FOTD FS 1) 1)
1) 1)
R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 Outer annular radius Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer annular annular annular annular annular annular annular annular annular annular annular radius radius radius radius radius radius radius radius radius radius radius (in),
(in),
(in),
(in),
(in),
(in),
(in),
(in),
ring ring ring ring ring ring ring ring ring ring ring ring 1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
not used not used not used not used not used not used not used not used not used not used not used not used
- 5. OOOE+01
- 7. 071E+01 0O.000E+00
- 0. OOE+00 0.000E+00 0.000E+00 0. 000E+00 0.000E+00
- 0. OOOE+00 0. 000E+00
- 0. 0OOE+00 0.000E+00 RAD SHAPE(
1)
RAD SHAPE) 2)
RADSHAPE(
3)
RADSHAPE(
4)
RADSHAPE) 5)
RAD SHAPE(
6)
RADSHAPE) 7)
PAD SHAPE) 8)
RADSHAPE) 9)
HADSHAPE(l0)
RAD_SHAPE(ll)
RADSHAPE(12)
- RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:39 Page 5
Summary UMNC14_r~a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CT4\\IWCI4_ROA 5M.RAD Site-Specific Parameter Summary (continued)
ParamReter R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R019 KRG19 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 Ri9B R19B R19B R19B R19B Fractions Ring 1
Ring.
2 Ring 3
Ring 4
Ring 5
Ring 6
Ring 7
Ring 8
Ring 9
Ring T0 Ring 11 Ring 12 of annular areas within AREA:
Fruits, vegetables and grain consumption (kg/yr)
Leafy vegetable consumption (kg/yr)
Milk consumption (L/yr)
Meat and poultry consumption (kg/yr)
Fish consumption (kg/yr)
Other seafood consumption (kg/yr)
Soil ingestion rate (g/yr)
Drinking water intake (L/yr)
Contamination fraction of drinking water Contamination fraction of household water Contamination fraction of livestock water Contamination fraction of irrigation water Contamination fraction of aquatic food Contamination fraction of plant food Contamination fraction of meat Contamination fraction of milk Livestock fodder intake for meat (kg/day)
Livestock fodder intake for milk (kg/day)
Livestock water intake for meat (L/day)
Livestock water intake for milk (L/day)
Livestock soil intake (kg/day)
Mass loading for foliar deposition (g/m**3)
Depth of soil mixing layer (m)
Depth of roots (m)
Drinking water fraction from ground water Household water fraction from ground water Livestock water fraction from ground water Irrigation fraction from ground water Wet weight crop yield for Non-Leafy (kg/m**2)
Wet weight crop yield for Leafy (kg/m**2)
Wet weight crop yield for Fodder (kg/m**2)
Growing Season for Non-Leafy (years)
Growing Season for Leafy (years) no no no nc no no no no nc no no no no no no no no no 0.
no no no no no no no no no no no no no no no 1.
no no no no no no no no no no User Input Default ot used 1.GG0E+00 ot used 2.732E-01 ot used O.OGOE+00 ot used O.D00E+00
)t used G0.000E+00
)t used O.0O0E+00 t used 0.000E+00 t used 0.00GE+00 t used 0.0OGE+00
)t used O.000E+00
)t used O.GOE+00 t used O.000E+00 t used 1.600E+02
)t used 1.400E+01 t used 9.200E+01
)t used 6.300E+01
)t used 5.400E+00
)t used 9.OOE-01 G00E+00 3.650E+01 t used 5.100E+02
)t used 1.OGOEf00
,t used 1.GG0E+00
,t used 1.000E+00
>t used 1.OG0E+00
)t used 5.OOE-01
,t used 1-1
)t used 1-1
)t used 1-1 t used 6.800E+01 t used 5.500E+01
)t used 5.OO0E+01
)t used 1.600E+02
)t used 5.000E-01
,t used 1.000E-04 500E-01
.1.500E-01 t used 9.0O0E-01 t used 1.0OGE+00 t used 1.OOGE+00 t used 1.0OGE+00 t used 1.GO0E+00 it used 7.000E-01
't used 1.500E+00 t used 1.100E+00 t used j.700E-01
- t used 2.500E-01 Used by RESRAD (If different from user input)
FRACA 1)
FRACA 2)
FRACA 3)
FRACA 4)
FRACA 5)
FRACA 6)
FRACA 7)
FRACA 5
8)
FRACA 95)
FRACA(10)
FRACA (11)
FRACA(12)
DIET (1)
DIET (2)
DIET (3)
DIET (4)
DIET (5)
DIET (6)
SOIL DWI FDW FHHW FLW FIRW FR9 FPLANT FMEAT FMILK LFI5 LFI6 LWI5 LWI6 LSI MLFD DM DROOT FGWDW FGWHH FGWLW FGWIR YV (1)
YV (2)
YV (3)
TE (1)
TE (2)
Parameter Ne R19B I Growing Season for Fodder (years) not used 8.OOE-02 I ITE (3)
- RESRAD, Version 6.5 T;7s Limit = 30 days 05/04/2012 12:39 Page 6
Summary UMNC14_r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\IWCl4_RCA_5M.RAD Site-Specific Parameter Summary (continued)
Menu Parameter RI9B Translocation Factor for Non-Leafy R19B Translocation Factor for nLeafy RI9B Translocation Factor for Fodder R19B Dry Foliar Interception Fraction for Non-Leafy R19B Dry Foliar Interception Fraction for Leafy R19B Dry Foliar Interception Fraction for Fodder R19B Wet Foliar Interception Fraction for Non-Leafy R19B Wet Foliar Interception Fraction for Leafy R19B Wet Foliar Interception Fraction for Fodder RI9B Weathering Removal Constant for Vegetation C14 C-12 concentration in water (g/cm**.3)
C14 C-12 concentration in contaminated soil (g/g)
C14 Fraction of vegetation carbon from soil C14 Fraction of vegetation carbon from air C14 C-14 evasion layer thickness in soil (m)
C14 C-14 evasion flux rate from soil (1/sec)
C14 C-12 evasion flux rate from soil (I/sec)
C14 Fraction of grain in beef cattle feed C14 Fraction of grain in milk cow feed STOR Storage times of contaminated foodstuffs (days)
STOR Fruits, non-leafy vegetables, and grain STOR Leafy vegetables STOR Milk STOR Meat and poultry STOR Fish STOR Crustacea and mollusks STOR Well water STOR Surface water STOR Livestock fodder R021 Thickness of building foundation (m)
R021 Bulk density of building foundation (g/cm**3)
R021 Total porosity of the cover material R021 Total porosity of the building foundation R021 Volumetric water content of the cover material R021 Volumetric water content of the foundation R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material R021 in foundation material R021 in contaminated zone soil R021 Radon vertical dimension of mixing (m)
R021 Average building air exchange rate (1/hr)
R021 Height of the building (room)
(m)
R021 Building interior area factor R021 Building depth below ground surface (m)
R021 Emanating power of Rn-222 gas R021 Emanating power of Rn-220 gas TITL Number of graphical time points
-4
- 1
- 1 User Input Default not used 1.000E-01 not used I 1.000E+00 not used 1.000E+00 not used 2.500E-01 not used 2.500E-01 not used 2.500E-01 not used 2.500E-01 not used 2.500E-01 not used 2.500E-01 not used 2.000E+01 2.000E-05 2OOOE-05 3.000E-02 3.000E-02 2.000E-02 2.000E-02 9,800E-01 9.800E-01 3.000E-01 3OOOE-01 7.OOOE-07 7.OOOE-07 1.000E-10 1.OOE-10 8.000E-01 8.OOOE-01 2.OOOE-01 2.OOOE-01 1.400E+01 1.400E+01 1.000E+00 1.000E+00 1.000E+00 1.000E+00 2.000E+01 2.OOOE+01 7.OOOE+00 7.000E+00 7.000E+00 7.000E+00 1.OOOE+00 1.000E+00 1.000E+00 1.000E+00 4.500E+01 4.500E+01 not used 1.500E-01 not used 2.400E+00 not used 4.000E-01 not used 1.OO0E-01 not used 5.OOOE-02 not used 3.OOOE-02 not used 2.000E-06 not used 3.000E-07 not used 2.000CE-06 not used 2.000E+00 not used 5.OOE-01 not used 2.500E+00 not used 0.000E+00 not used 1-.000E+00 not used 2.500E-01 not used 1.500E-01 32 Used by RESRAD (If different from user input)
Parameter Name TIV(1)
TIV(2)
TIV(3)
RDRY (1)
RDRY(2)
RDRY(3)
RWET(i)
RWET(2)
RWET(3)
WLAM C12WTR C12CZ CSOIL CAIR DMC EVSN REVSN AVFG4 AVFG5 STOR T(i)
STORPT(2)
STOR T(3)
STORPT(4)
STOR T(5)
STOR T(6)
STOR T(7)
STORP_T(8)
STORPT(9)
FLOORI DENSFL TPCV TPFL PH20CV PH2OFL DIFCV DIFFL DIFCZ HMIX REXG HRM FAI DMFL EMANA(l)
EMANA(2)
NPTS
- RESRAD, Version 6.5 T*i Limit = 30 days 05/04/2012 12:39 Page 7
Summary UMC14_rOa_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_ROA_5M.RAD Site-Specific Parameter Summary (continued)
User I
Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) L Name I
I TITL Maximum number of integration points for dose j
17 j
I LYMAX TITL Maximum number of integration points for risk 257 j
j KYMAX Summary of Pathway Selections Pathway User Selection I --
external gamma active 2 --
inhalation (w/o radon)l active 3 --
plant ingestion suppressed 4 --
meat ingestion suppressed 5 --
milk ingestion suppressed 6 --
aquatic foods suppressed 7 --
drinking water suppressed 8 --
soil ingestion active 9 --
radon suppressed Find peak pathway doses active
RESRAD, Version 6.5 T, Limit = 30 days 05/04/2612 12:39 Page 8
Summary IUMC14_tra_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWC14 ROA 5M.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g C-14 1.OGOE+00 Area:
Thickness:
Cover Depth:
50.00 square meters 1.00 meters 5.00 meters Total Dose TDOSE(t),
mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t)
= Fraction of Basic Dose Limit Received at Time (t) t (years):
0.DOOE+00 1.OO0E+00 3.OOOE+00 1.OO0E+01 3.O0DE+01 1.OODE+02 3.000E+02 1.000E+03 TDOSE(t):
0.000E+00 0.000E+00 0.000E+00 0o.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 M(t):
0.000E+00 0.000E+00 0.000E+00 D.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Maximum TDOSE(t):
0.000E+00 mrem/yr at t = 0.005E+00 years
- RESRAD, Version 6.5 T1s Limit = 30 days 05/04/2012 12:39 Page 9
Summary : UMC14_r~a_5m File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWC14 R0A 5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t
= 0.O0OE+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 Total 0.OOOE+00 0.0000 0.OOOE+00 0,0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Milk Soil mrem/yr
- fract, mrem/yr frac 0.000E+00 0.0000 0.'000E+00 0.OC 0.OOOE+00 0.0000 0.OOOE+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.OOOE+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Total 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5.
Ti Limit = 30 days 05/04/2012 12:39 Page 10 Summary iUMC14_r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\IWC14_ROA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Radio-Nuclide C-14 Total Ground Inhalation Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.OOOE+00 0*0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Soil mrem/yr frac 0.OOOE+00 O.OC O.OooE+00 O.OC Water Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.OOOE+00 0.0000 Fish mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.OC 0.OOOE+00 0.OC
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:39 Page 11 Summary UM'CI4_rOea5m File
- C:\\RESRA*DFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\IWCl4_R0A_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Meat Milk Soil mrem/yr fract.
mrem/yr fract.
mrem/yr frac 0.000E+00 0.0000 0.00OE+00 0.0000 0.000E+00 0.0C 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOOE+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OOOE+00 0.0000 0,OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+O0 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T;Limsit = 30 days 05/04/2012 12:39 Page 12 Summary : UM C14"r0a_5m File
- C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWC14 RDA 5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0,OOOE+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0,000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.OC 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Dependent Pathways Radio-Nuclide C-14 Total Water mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Fish mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 O.OOOE+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.0C 0.0OOE+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:39 Page 13 Summary UMC14_rOa.5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCl4_ROA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Radio-Nuclide C-14 Total Ground mrem/yr fract.
6.000E+00 0.0000 0.OOOE+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.0OOE+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t
= 3.000E+01 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.OOOE+00 0.0000 Total 0.OOOE+00 0.0000 Fish mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 O.O00E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0.OC 0.OOOE+00 0.0C
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:39 Page 14 Summary UM C14_rOa 5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWC14 R0A 5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mremiyr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 O.000E+00 0.0000 0.000E+00 0.0000 mrem/yr frac 0.000E+00 0.0C 0.000E+00 0.0C Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total O.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.OC 0.OOOE+00 0.OC
- Sum of all water independent and dependent pathways.
PRSRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:39 Page 15 Summary :UM _C14 rOa 5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCI4 ROA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.000E+00 0.0c 0.000E+00 0.0C Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.0C 0.000E+00 0.OC
- Sum of all water-independent and dependent pathways.
RESRAD, Version 6.5 T; Limit = 30 days 05/04/2012 12:39 Page 16 Summary : UMC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWCI4 R0A 5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+03 years Water Independent Pathways (Inhalation excludes radon)
Radio-Nuclide C-14 Total Ground mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract."
0.OOOE+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
O.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.OOE+00 0.0C 0.oo0E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+03 years Water Dependent Pathways Radio-Nuclide C-14 Total Water mrem/yr fract.
0.OOOE+00 0.0000 O.O00E+00 0.0000 Fish mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.0C O.OOOE+00 0.OC
- Sumn of all water independent and dependent pathways.
RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:39 Page 17 Surmnary UMC14_r~a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\IWC14_RCA 5M.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)
Wi)
(j)
Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 C-14 C-14 1.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 The DSR includes contributions from associated (half-life
- 30 days) daughters.
Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 C-14
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- At specific activity limit Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 0.000E+00 years Nuclide Initial tmuin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)
Wi)
(pCi/g)
(years)
(pCi/g)
(pCi/g)
C-14 1.OOOE+00 0.000E+00 0.000E+00 *4.455E+12 O.OOOE+00 "4.455E+12
- At specific activity limit
RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:42 Page 1
Summary : Building Occupant C14_rCa_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOCl4_R0A_5M.RAD Table of Contents Part I:
Mixture Sums and Single Radionuclide Guidelines CV-7 R)
Dose Conversion Factor (and Related) Parameter Summary...
Site-Specific Parameter Summary..........................
Summary of Pathway Selections......
Contaminated Zone and Total Dose Summary.................
Total Dose Components Time = O.000E+00....................................
Time = 1.OOOE+00......................................
Time 3.OOOE+00 Time 1.000E+01 Time = 3.000E+01 Time = 1.00DE+02.
Time = 3.OO E+02....................................
Time = 1.000E+03....................................
Dose/Source Ratios Summed Over All Pathways..............
Single Radionuclide Soil Guidelines......................
Dose Per Nuclide Summed Over All Pathways................
Soil Concentration Per Nuclide...........................
2 3
7 8
9 10 11 12 13 14 15 16 17 17 18 18 65hvt4 (I (
OPUz V
- o
RESRAD, Version 6.5 Th Limit = 30 days 05/04/2012 12:42 Page 2
Summary : Building OccupantC14_r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOCI4_ROA'5M.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 12 & FGR 11 Menu Parameter i
B-I B-I B-I DCF's for external ground radiation, (mrem/yr)/(pCi/g)
C-14 (Source: FGR 12)
Dose conversion factors for inhalation, mrem/pCi:
C-14(p)
(Class: ORGANIC)
C-14(g)
(Class: C02)
Dose conversion factors for ingestion, mrem/pCi:
C-14 Food transfer factors:
, plant/soil concentration ratio, dimensionless C-14
, beef/livestock-intake ratio, (pCi/kg)/(pCi/d)
, milk/livestock-intake ratio, (pCi/L)/(pCi/d)
Current Value#
1.345E-05 2.090E-06 2.350E-08 2.090E-06 5.500E+00 3.100E-02 1.200E-02 5.000E+04 9.100E+03 Base Parameter Case*
Name 1.345E-05 DCFI(
1) 2.090E-06 DCF2(
1) 2.350E-08 CI4GInhDCF 2.090E-06 DCF3(
1) 5.500E+00 RTF(
1,1) 3.100E-02 RTF(
1,2) 1.200E-02 RTF(
1,3) 5.000E+04 BIOFAC(
1, 9.100E+03 BIOFAC(
1, D-34 D-34 D-34 D-34 D-5 D-5 D-5 Bioaccumulation factors, fresh water, L/kg:
, fish C-14
, crustacea and mollusks 1) 2)
- For DCFl(xxx) only, factors are for infinite depth & area.
See
- Base Case means Default.Lib w/o Associate Nuclide contributions.
ETFG table in Ground Pathway of Detailed Report.
- RESRAD, Version 6.5 T's Limit = 30 days 05/04/2012 12:42 Page 3
Summary Building OccupantC14 r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOCl4_ROA_5M.RAD Site-Specific Parameter Summary Menu Parameter I
R011 Area of contaminated zone (m**2)
R011 Thickness of contaminated zone (m)
R011 Fraction of contamination that is submerged R011 Length parallel to aquifer flow (m)'
R011 Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
C-14 R012 Concentration in groundwater (pCi/L):
C-14 R013 Cover depth (m)
R013 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013 Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 Irrigation mode R013 Runoff coefficient R013 Watershed area for nearby stream or pond (m**2)
R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m/yr)
R014 Saturated zone hydraulic gradient R014 Saturated zone b parameter R014 Water table drop rate (m/yr)
R014 Well pump intake depth (m below water table)
R014 Model: Nondispersion (ND) or Mass-Balance (MB)
R014 Well pumping rate (m**3/yr)
User Input Default 5.000E+01 1.OOOE+04 1.000E+00 2.OOOE+00 0.000E+O0 0.000E+00 not used 1.000E+02 2.500E+01 3.000E+01 0.OOOE+00 0.000E+00 1.000E+00 1.000E+00 3.000E+00 3.000E+00 1.000E+01 1.000E+01" 3.000E+01 3.000E+01 1.000E+02 1.000E+02 3.000E+02 3.0005+02 1.000E+03 1.000E+03 not used 0.000E+00 not used I10.000E+00 1.000E+00 0.000E+00 not used 0.000E+00 5.000E+00 0.O00E+00 1.500E+00 1.500E+00 1.000E-03 1.000E-03 1.500E+00 1.500E+00 1.000E-03 1.000E-03 4.000E-0-1 4.OOOE-01 2.000E-01 2.000E-01 1.000E+01 I1.000E+01 5.300E+00 5.300F+00 2.000E+00 2.000E+00 not used 8.000E+00 5.OOOE-01 5.OOE-01 1.000E+00 1.000E+00 2.000E-01 2.000E-01 overhead overhead 2.0005-01 2.OOOE-01 not used 1.000E+06 not used 1.000E-03 not used 1.500E+00 not used 4.OOOE-01 not used 2.OOOE-01 not used 2.000E-01 not used 1.0005+02 not used 2.000E-02 not used 5.300E+00 not used 1,000E-03 not used 1.000E+01 not used ND not used 2.500E+02 Used by RESRAD (If different from user input)
Param Nam AREA THICKO SUBMFRJ LCZPAQ BRDL TI T(
2)
T)(3)
T(
4)
T(
5)
T(
6)
T(
7)
T( 8)
T(
9)
T(10)
Sl(1)
W1( 1)
COVERO DENSCV VCV DENSCZ VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA EPS DENSAQ TPSZ EPSZ FCSZ HCSZ HGWT BSZ VWT DWIBWT MODEL UW eter e
ACT
- RESRAD, Version 6.5 T11 Limit = 30 days 05/04/2012 12:42 Page 4
Summary : Building OccupantC14_r0a_5m File
- C:\\RESPADFAMILY\\RESPAD\\6.5\\USERFILES\\UM\\Cl4\\BOCI4_R0A_5M..PAD Site-Specific Parameter Summary (continued)
Menu R015 R015
'RO15 R015 R015 R015 R015 R015 R016 R016 R016 R016 R016 R016 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 Parameter Number Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
of unsaturated zone strata zone 1, thickness (m) zone 1, soil density (g/cm**3) zone 1, total porosity zone 1, effective porosity zone 1, field capacity zone 1, soil-specific.b parameter zone 1, hydraulic conductivity (m/yr)
Distribution coefficients for C-14 Contaminated zone (cm**3/g)
Unsaturated zone 1 (cm**3/g}
Saturated zone (cm**3/g)
Leach rate (/yr)
Solubility constant Inhalation rate (m**3/yr)
Mass loading for inhalation (g/m**3)
Exposure duration Shieiding factor, inhalation Shielding factor, external gamma Fraction of time spent indoors Fraction of time spent outdoors (on site)
Shape factor flag, external gamma Radii of shape factor array (used if FS =
Outer annular radius (m),
ring 1:
Outer annular radius (m),
ring 2:
Outer annular radius (m),
ring 3:
Outer annular radius (m),
ring 4:
Outer annular radius (m),
ring 5:
Outer annular radius (m),
ring 6:
Outer annular radius (m),
ring 7:
Outer annular radius (m),
ring 8:
Outer annular radius (m),
ring 9:
Outer annular radius (m),
ring 10:
Outer annular radius (m),
ring 11:
Outer annular radius (m),
ring 12:
User Input not used not used not used not used not used not used not used not used 1.000E+00 not used not used 0.000E+00 0.000E+00 not used not used 3.000E+01 not used 7.OOE-01 2.285E-01 0.00OE+00 1.00OE+00 not used not used not used not used not used not used not used not used not used not used not used not used
)
Default 1
4.000E+00 1.500E+00 4.00OE-01 2.OOOE-01 2.000E-01 5.300E+00 1.OOOE+01
- 0. 000E+00
- 0. 000E+00
- 0. 000E+00 0.OOOE+00 0.000E+00 8.400E+03 1.OODE-04 3.000E+01 4.OOOE-01 7.OOOE-01 5.000E-01
- 2. 50DE-01
- 1. 000E+00
- 5. 00OE+01 7.071E+01 0.OOO0E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0O00E+00 0.OOOE+00 Used by RESRAD (If different from user input)
Parameter Name 2.746E-01 not used
>0 shows circular AREA.
DCNUCC(
DCNUCU(
DCNUCS(
ALEACH(
SOLUBK(
1) 1,1) 1)*
1) 1)
NS H(1)
DENSUZ(1)
TPUZ (1)
EPUZ (1)
FCUz (1)
BUZ (1)
HCUZ (1)
-1)
INHALR MLINH ED SHF3 SHF1 FIND FOTD FS RADSHAPE) 1)
RAD SHAPE(
2)
RAD SHAPE(
3)
RAD_SHAPE(
4)
PAD SHAPE(
5)
PAD_SHAPE(
6)
RAD_SHAPE(
7)
PAD_SHAPE(
8)
RADSHAPE) 9)
PAD_SHAPE(10)
PAD_SHAPE(i1)
PAD_SHAPE(12)
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:42 Page 5
Summary : Building OccupantC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOCI4_RCA_5M.RAD Site-Specific Parameter Summary (continued)
Menu Parameter R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R018 R018 R018 R018 R018 R018 R01B R018 R018 R018 R018 R018 R018 R018 R018 R018 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 RO19 Fractions Ring I
Ring 2
Ring 3
Ring '4 Ring 5
Ring 6
Ring 7
Ring 8
Ring 9
Ring 10 Ring 11 Ring 12 of annular areas within AREA:
Fruits, vegetables and grain consumption (kg/yr)
Leafy vegetable consumption (kg/yr)
Milk consumption (L/yr)
Meat and poultry consumption (kg/yr)
Fish consumption (kg/yr)
Other seafood consumption (kg/yr)
Soil ingestion rate (g/yr)
Drinking water intake (L/yr)
Contamination fraction of drinking water Contamination fraction of household water Contamination fraction of livestock water Contamination fraction of irrigation water Contamination fraction of aquatic food Contamination fraction of plant food Contamination fraction of meat Contamination fraction of milk Livestock fodder intake for meat (kg/day)
Livestock fodder intake for milk (kg/day)
Livestock water. intake for meat (L/day)
Livestock water intake for milk (L/day)
Livestock soil intake (kg/day)
Mass loading for foliar deposition (g/m**3)
Depth of soil mixing layer (m)
Depth of roots (m)
Drinking water fraction from ground water Household water fraction from ground water Livestock water fraction from ground water Irrigation fraction from ground water Wet weight crop yield for Non-Leafy (kg/m**2)
Wet weight crop yield for Leafy (kg/m**2)
Wet weight crop yield for Fodder (kg/m**2)
Growing Season for Non-Leafy (years)
Growing Season for Leafy (years)
Growing Season for Fodder (years)
User Input Default not used 1.j00E+00 not used 2.,732E-01 not used 0.000E+00 not used 0.C00E+00 not used j.D00E+00 not used C.000E+00 not used 0.000E+00 not used 0.000E+00 not used 0.000E+00 not used 0.000+00 not used 0.000F+00 not used 0.000E+00 not used 1.600E+02 not used 1.400E+01 not used 9.200E+01 not used 6.300E+01 not used 5.400E+00 not used 9.C000-01 not used 3.650E+01 not used 5.100E+02 not used 1.000E+00 not used 1.000E+00 not used I1.000E+00 not used 1.005E+00 not used 5.C00E-01 not used 1-1 not used 1-1 not used
-1 not used 6.800E+01 not used 5.500E+01 not used 5.OD0E+01 not used 1.600E+02 not used 5.00DE-01 not used 1.000E-04 not used 1.500E-01 not used 9.000E-01 not used 1.000E+00 not used 1.000E+00 not used 1.000E+00 not used 1.000E+00 not used 7.000E-01 not used 1.500E+00 not used j 1.100E+00 not used 1.70DE-01 not used j 2.500E-01 not used 8.000E-02
-F
- 1 Used by RESRAD (If different from user input)
Parameter Name FRACA(
1)
FRACA(
2)
FRACA(
3)
FRACA(
4)
FRACA(
5)
FRACA(
6)
FRACA) 7)
FRACA(
8)
FRACA(
9)
FRACA(10)
FRACA(Ii)
FRACA(12)
DIET(l)
DIET(2)
DIET(3)
DIET (4)
DIET(5)
DIET(6)
SOIL DWI FDW FHHW FLW FIRW FR9 FPLANT FMEAT FMILK LFI5 LFI6 LWI5 LWI6 LSI MLFD DM DROOT FGWDW FGWHH FGWLW FGWIR YV(1)
YV(2)
YV(3)
TE(1)
TES(2)
TES(3)
- RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:42 Page 6
Summary Building OccupantC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOCl4_ROA_5M.RAD Site-Specific Parameter Summary (continued)
Menu R19B R19B R19B R.19B R19B
-R1gB R19B R.19B R19B R19B C14 C14 C14 C14 C14 C14 C14 C14 C14 STOR STOR STOR STOR STOR STOR STOR STOR STOR STOR R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 TITL Parameter Translocation Factor for Non-Leafy Translocation Factor for Leafy Translocation Factor for Fodder Dry Foliar Interception Fraction for Non-Leafy Dry Foliar Interception Fraction for Leafy Dry Foliar Interception Fraction for Fodder Wet Foliar Interception Fraction for Non-Leafy Wet Foliar Interception Fraction for Leafy Wet Foliar Interception Fraction for Fodder Weathering Removal Constant for Vegetation C-12 concentration in water (g/cm**3)
C-12 concentration in contaminated soil (g/g)
Fraction of vegetation carbon from soil Fraction of vegetation carbon from air C-14 evasion layer thickness in soil (m)
C-14 evasion flux rate from soil (1/sec)
C-12 evasion, flux rate from soil (1/sec)
Fraction of grain in beef cattle feed Fraction of grain in milk cow feed Storage times of contaminated foodstuffs (days):
Fruits, non-leafy vegetables, and grain Leafy vegetables Milk Meat and poultry Fish Crustacea and mollusks Well water Surface water Livestock fodder Thickness of building foundation (m)
Bulk density of building foundation (g/cm**3)
Total porosity of the cover material Total porosity of the building foundation Volumetric water content of the cover material Volumetric water content of the foundation Diffusion coefficient for radon gas (m/sec):
.in cover material in foundation material in contaminated zone soil Radon vertical dimension of mixing (m)
Average building air exchange rate (i/hr)
Height of the building (room)
(m)
Building interior area factor Building depth below ground surface (m)
Emanating power of Rn-222 gas Emanating power of Rn-220 gas Number of graphical time points User Input not used not used not used not used not used not used not used not used not used not used 2.OOOE-05 3.000E-02 2.00OE-02 9.800E-01 3.000E-01 7.00OE-07 1.00OR-10 8.000E-01 2.OOOE-01 1.400E+01 1.OOOE+00 1.OOOE+00 2.OOOE+01 7.OOOE+00 7.000E+00 1.OOOE+00 1.OOOE+00 4.500E+01 not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used not used 32 Default 1.0ODE-01 1.OOOE+00 1.000E+00 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.00 OE+01 2.00 OE-05 3.00 OE-02
- 2. 00OE-02 9.800E-01 3.000E-01
- 7. 000E-07 1.000E-10 8.000E-01 2.000E-01 1.400E+01 1.OOOE-+00 1.000E-+00 2.000E-+01 7.OOOE+00 7.OOOE+00 1.OOOE+00 1.OOOE+00
- 4. 500E+01 l.500E-0l 2.400E+00 4 4.OOOE-01 1.OOE-01 5 5.000E-02 3 3.000E-02 2 2.00OE-06
- 3. 00OE-07 2 2.00OE-06 2.O00E+00 5.00OE-01 2 2.SOOE+00 0 0.OO0E+00
-1.OO0E+00 2.500E-01 1.500E-01 Used by RESRAD (If different from user input)
Parameter Name TIV(1)
TIV(2)
TIV(3)
RDRY (1)
RDRY(2)
RDRY (3)
RWET (1)
RWET(2)
RWET (3)
WLAM C12WTR C12CZ CSOIL CAIR DMC EVSN REVSN AVFG4 AVFG5 STOR T(1)
STORPT(2)
STOR T(3)
STORP_T(4)
STOR T(5)
STORP_T(6)
STORP.T(7)
STOR T(8)
STOP._T(9)
FLOOR1 DENSFL TPCV TPFL PH2OCV PH2OFL DIFCV DIFFL DIFCZ HMIX REXG HRM FAI DMFL EMANA (1)
EMANA(2)
NPTS
- RESRAD, Version 6.5-T*i Limit =.30 days 05/04/2012 12:42 Page 7
Summary : Building OccupantC14_r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOCI4_R0A_5M.RAD Site-Specific Parameter Summary (continued)
Menu I
User Input I
Used by RESRAD Default (If different from user input)
Parameter Name Parameter i
I i
TITL Maximum number of integration points for dose 17 I
LYMAX TITL Maximum number of integration points for'risk 257 j
I KYMAX Summary of Pathway Selections Pathway I
User Selection 1 --
external gamma active 2 --
inhalation (w/o radon)l suppressed 3 --
plant ingestion suppressed 4 --
meat ingestion suppressed 5 --
milk ingestion suppressed 6 --
aquatic foods suppressed 7 --
drinking water suppressed 8 --
soil ingestion suppressed 9 --
radon suppressed Find peak pathway doses active
RESRAD, Version 6.5 T1 Limit = 30 days 05/04/2012 12:42 Page 8
Summary : Building Occupant C14_rOa_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOCI4_R0A_5M.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area:
Thickness:
Cover Depth:
50.00 square meters 1.00 meters 5.00 meters C-14
- 1. OOOE+00 Total Dose TDOSE(t),
mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years):
0.000E+00 1.000E+00 3.OOOE+00 1.000E+01 3.000E+01 1.000E+02 3.OOOE+02 1.000E+03 TDOSE(t):
0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 M(t) :
0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 Maximum TDOSE(t):
0.000E+00 mrem/yr at t = 0.000E+00 years
RESRAD, Version 6.5 T, Limit = 30 days 05/04/2012 12:42 Page 9
Summary : Building Occupant C14_r0ae5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\BOCI4_ROA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual.Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.OOOE+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 O.OOE+00 0.0000 Total 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Plant Meat mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t
= 0.000E+00 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Fish mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
O.O00E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.OC 0.OOOE+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 Tle Limit = 30 days 05/04/2012 12:42 Page 10 Summary Building OccupantC14_r0a_5m File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOC14 R0A 5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.'oOOE+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.6000 Radon mrem/yr fract.
O.000E+00 0.0000 0.OOOE+00 0.0000 Plant Meat mrem/yr fract.
mrem/yr fract.
0,000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Milk "mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.000E+00 0.0C 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t
= 1.OOOE+00 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.O0OE+00 0.0000 Fish mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000+E00 0.0000 Meat mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0,0000 All Pathways mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:42 Page 11 Summary Building Occupant C14_r~a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOCl4_RCA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.CCCE+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OC0E+00 0.000C 0.OCOE+00 0.000C 0.OCOE+00 0.000C 0.OCOE+00 0.000C 0.0CCE+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.COE+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.OCOE+00 0.0C 0.000E+00 C.0C Total.Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOE+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OOOE+00 0.0000 0.OOCE+00 0.0000 0.OCOE+00 0.0000 0.OOCE+00 0.0000 0.COOE+00 0.0000 0.OO0E+00 0:0000 Total 0.C00E+00 0.0000 0.OO0E+00 0.0000 0.000E+00 0.0000 0.OOE+00 0.0000 O.0OOE+00 0.0000 0.0OOE+00 0.0000 All Pathways mrem/yr frac 0.000E+00 C.0C 0.O0OE+00 0.OC
- Sun of all water independent and dependent pathways.
RESRAD, Version 6.5 T1 Limit = 30 days 05/04/2012 12:42 Page 12 Summary Building Occupant C14_r0a_5m File C:\\RESRADOFAMILY\\RESRAD\\6.SVUSERFILES\\UM\\CI4\\BOCl4_ROA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and As mrem/yr and Fraction of Total Dose At t = 1.OOOE+01. years Water Independent Pathways (Inhalation excludes radon)
Pathways (p)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.OOOE+00 0.0000 Total 0.OOOE+00 0.0000 Inhalation Radon Plant Meat mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.OOOE+00 Q.OC 0.OOOE+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+01 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.OOOE+00 0.0000 Total 0.OOOE+00 0.0000 Fish mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
O.OOOE+00 0.0000 O.OOOE+00 0.0000 Meat mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0,0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0.0C 0.000E+00 0.0C
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T1 Limit = 30 days 05/04/2012 12:42 Page 13 Summary : Building Occupant C14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOC14_ROA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.O0OE+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Meat mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.O00E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.OC 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Dependent Pathways Radio-Nuclide C-14 Total Water mrem/yr fract.
O.O00E+00 0.0000 0.000E+00 0.0000 Fish mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T1 Limit = 30 days 05/04/2012 12:42 Page 14 Summary Building Occupant C14_r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOCI4_R0A_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As m-rem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
. mrem/yr fract.
mrem/yr "fract.
C-14 0.OOOE+00 0.0000 0.00OE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOE+00 0.0000 Total 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr-fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.00DE+00 0.0C 0.OOOE+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.0OOE+02 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Fish Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.O0OE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0.0C 0.000E+00 0.0C
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 Tl Limit = 30 days 05/04/2012 12:42 Page 15 Suimmary : Building Occupant CI4_r0a_5m File
- C:\\RESRPAD_FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\BOCI4_R0A_5M.PAD Total Dose Contributions.TDOSE(i,p,t) for Individual Radionuclideý (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Fish Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.QOOO 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 T*i Limit = 30 days 05/04/2012 12:42 Page 16 Summary Building Occupant C14_r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOC14 R0A 5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As nrem/yr and Fraction of Total Dose At t
= 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC 0.OOOE+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 All Pathways, mrem/yr frac 0.OOE+00 o.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T11 Limit = 30 days 05/04/2012 12:42 Page.
17 Summary Building Occupant C14_r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\Cl4\\BOCI4_R0A 5M.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)
Wi)
(j)
Fraction 0.000E+00 1.OOOE+00 3.000E+00 1.OOOE+01 3.000E+01 1.OOOE+02 3.000E+02 1.OOOE+03 C-14 C-14 1.000E+00 0.000E+00 0.000E+00 0.000E+00 0.O0OE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 The DSR includes contributions from associated (half-life
- 30 days) daughters.
Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i) t=.0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 C-14
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- 4.455E+12
- At specific activity limit Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 0.OOOE+00 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)
(i)
(pCi/g)
(years)
(pCi/g)
(pCi/g)
C-14 1.000E+00 0.000E+00 0.000E+00 *4.455E+12 0.O0OE+00 *4.455E+12
- At specific activity limit
- RESRAD, Version 6.5 T1 Limit = 30 days 05/04/2012 12:42 Page.18 Summary Building Occupant C14_r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\BOC14_ROA_5M.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
DOSE(j,t),
mrem/yr (j)
(i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 C-14 C-14 1.000E+00, 0.OOOE+00 0.000E+00 0.OOOE+00 o.oooE+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
1.000E+02 3.000E+02 1.000E+03 0.000E+00 0.000E+00 0.000E+00 Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
S(j,t), pCi/g (j)
(i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 C-14 C-14 1.OOOE+00 1.000E+00 7.598E-01 4.386E-01 6.412E-02 2.636E-04 1.174E-12 1.617E-36 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
RESCALC.EXE execution time =
8.58 seconds
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:56 Page 1
Summary Subsistence FarmerC14 r0a 0m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\Cl4\\SFCI4_RCAOM.RAD Table of Contents Part I:
Mixture Sums and Single Radionuclide Guidelines K')
Dose Conversion Factor (and Related) Parameter Summary...
Site-Specific Parameter Summary...........................
Summary of Pathway Selections.............................
Contaminated Zone and Total Dose Summary.................
Total Dose Components Time = 0.000E+00....................................
Time = 1.000E+00....................................
Time = 3.000E+00 Time = 1.000E+01 Time = 3.000E+01 Time = 1.000E+02 Time 3.000E+02 Time 1.000E+03......................................
Dose/Source Ratios Summed Over All Pathways..............
Single Radionuclide Soil Guidelines......................
Dose Per Nuclide Summed Over All Pathways................
Soil Concentration Per Nuclide............................
2 3
7 8
9 10 11 12 13 14 15 16 17 17 18 18 0-19 0
VA,
- 0. (o
RESRAD, Version 6.5 T'1 Limit = 30 days 05/04/2012 12:56 Page 2
Summary : Subsistence FarmerC14_r0a Cm File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\SFCI4_RCACM.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 12 & FGR 11 Menu Parameter A-I DCF's for external ground radiation, (mrem/yr)/(pCi/g)
A-I C-14 (Source: FGR 12)
B-I Dose conversion factors for inhalation, mrem/pCi:
B-I C-14(p)
(Class: ORGANIC)
B-I C-14(g)
(Class: C02)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 C-14 Current Value#
1.345E-05 2.09CE-06 2.350E-08 2.090E-06 5.500E+00 3.100E-02 1.200E-02 5.000E+04 9.100E+03 Base Parameter Case*
Name 1.345E-05 DCF1(
1) 2.090E-06 DCF2(
1) 2.350E-08 Cl4GInhDCF 2.090E-06 DCF3(
1) 5.500E+00 RTF(
1,1) 3.100E-02 RTF(
1,2) 1.200E-02 RTF(
1,3) 5.000E+04 BIOFAC(
1,1) 9.100E+03 BIOFAC(
1,2)
D-34 D-34 D-34 D-34 D-5 D-5 D-5 Food transfer factors:
, plant/soil concentration ratio, dimensionless C-14
, beef/livestock-intake ratio, (pCi/kg)/(pCi/d)
, milk/livestock-intake ratio, (pCi/L)/(pCi/d)
Bioaccumulation factors, fresh water, L/kg:
, crustacea and mollusks
- For DCFi(xxx) only, factors are for infinite depth & area.
See ETFG table in
- Base Case means Default.Lib w/o Associate Nuclide contributions.
Ground Pathway of Detailed Report.
- RESRAD, Version 6.5 T11i Limit = 30 days 05/04/2012 12:56 Page 3
Summary : Subsistence Farmer C14 r0a Om File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCl4 ROA OM.RAD Site-Specific Parameter Summary Menu Parameter i
i R011 Area of contaminated zone (m**2)
R011 Thickness of contaminated zone (m)
R011 Fraction of contamination that is submerged R011 Length parallel to aquifer flow (m)
R011 Basic radiation dose limit (mrem/yr)
R011 Time since placement of material (yr)
R011 Times for calculations (yr)
R01 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R01 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R011 Times for calculations (yr)
R012 Initial principal radionuclide (pCi/g):
C-14 R012 Concentration in groundwater (pCi/L):
C-14 R013 Cover depth (m)
R013 Density of cover material (g/cm**3)
R013 Cover depth erosion rate (m/yr)
R013 Density of contaminated zone (g/cm**3)
R013 Contaminated zone erosion rate (m/yr)
R013 Contaminated zone total porosity R013 Contaminated zone field capacity R013 Contaminated zone hydraulic conductivity (m/yr)
R013 Contaminated zone b parameter R013 Average annual wind speed (m/sec)
R013 Humidity in air (g/m**3)
R013-Evapotranspiration coefficient R013 Precipitation (m/yr)
R013 Irrigation (m/yr)
R013 Irrigation mode R013 Runoff coefficient R013 Watershed area for nearby stream or pond (m**2)
R013 Accuracy for water/soil computations R014 Density of saturated zone (g/cm**3)
R014 Saturated zone total porosity R014 Saturated zone effective porosity R014 Saturated zone field capacity R014 Saturated zone hydraulic conductivity (m/yr)
R014 Saturated zone hydraulic gradient R014 Saturated zone.b parameter R014 Water table drop rate (m/yr)
R014 Well pump intake depth (m below water table)
R014 Model: Nondispersion (ND) or Mass-Balance (MB)
R014 Well pumping rate (m**3/yr)
User Input S.OOOE+01 1.000E+00 0.OOOE+00 1.OOOE+02 2.500E+01 0.000E+00 1.O000E+00 3.000E+00 1.000E+01 3.OOOE+01 1.OOOE+02 3.OOOE+02 1.OOOE+03 not used not used 1.000E+00 not used 0.000E+00 notused not used 1.500E+00 1.OOOE-03 4.OOOE-01 2.000E-01 1.000E+01 5.300E+00 2.OOOE+00 not used 5.00E-01I 1.000E+00 2.000E-01 overhead 2.000E-01 1.000E+06 1.000E-03 1.500E+00 4.OOOE-01 2.0OOE-01 2.000E-01 1.000E+02 2.000E-02 5.300E+00 1.000E-03 1.O00E+01 ND I
2.500E+02 Default
- 1. OOOE+04 2.00E+00 O.O000E+00
- 1. OOOE+02
- 3. OOOE+01
- 0. 000E+00
- 1. OOOE+00
- 3. 00 0E+0O I 000E+Ol 3.000E+Ol
- 1. OOOE+02
- 3. O0OE÷02
- 0. OOOE+03 0.000E+00 0.000OE+00 0.0 OOE+0O
- 0. OOOE+00
- 1. 500E+00
- 1. OOOE-03
- 1. 500E+/-00 I. O0E-03 4.OOOE-01
- 2. OOOE-01 l.OOD0E+Ol
- 5. 300E+O00 2.OOOE+OO S. OOOE+00 5.O0.0E-01 I. 000E+00
- 2. OOOE-01 overhead 2.000E-Ol 1.000E+06 1.OOOE-03 1.500E+00 4.O0DE-01 2.O00E-01 2.OOOE-O1 1.OOOE+02 2.OOOE-02I 5.300E--00 1.OOOF-03 I 1.DOOE+0l ND 2.500E+02 Used by RESRAD (If different from user input)
Parameter Name AREA THICKO SUBMFRACT LCZPAQ BRDL TI T(
2)
T(
3)
T(
4)
T(
5)
T(
6)
T(
7)
T(
8)
T(
9)
T(10)
WI( 1)
COVERO DENSCV VCV DENSCZ VCZ TPCZ FCCZ HCCZ BCZ WIND HUMID EVAPTR PRECIP RI IDITCH RUNOFF WAREA EPS DENSAQ TPSZ EPSZ'_
FCSZ HCSZ HGWT BSZ VWT DWIBWT MODEL UW
- RESRAD, Summary File Version 6.5 Tli Limit = 30 days 05/04/2012 12:56 Page 4
Subsistence Farmer C14 r0a 0m C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC4 _ROA OM.RAD Site-Specific Parameter Summary (continued)
User Input Default Used by RESRAD (If different from user input)
Parameter Name Menu Parameter I
I I
R015 R015 R015 R015 R015 R015 R015 R015 R016 R016 R016 R016 R016 R016 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 Number Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
of unsaturated zone strata zone 1, thickness (m) zone 1, soil density (g/cm**3) zone 1, total porosity zone 1, effective porosity zone 1, field capacity zone 1, soil-specific b parameter zone 1, hydraulic conductivity (m/yr)
Distribution coefficients for C-14 Contaminated zone (cm**3/g)
Unsaturated zone 1 (cm**3/g)
Saturated zone (cm**3/g)
Leach rate (/yr)
Solubility constant Inhalation rate (m**3/yr)
Mass loading for inhalation (g/m**3)
Exposure duration Shielding factor, inhalation Shielding factor, external gamma Fraction of time spent indoors Fraction of time spent outdoors (on site)
Shape factor flag, external gamma Radii of shape factor array (used if FS = -1):
1
- 4. OOOE+00
- 1. 500E+00
- 4. OOOE-01 2.OOOE-01 2.OOOE-01
- 5. 300E+00 1.OOOE+01
- 1. OOOE+00
- 1. OOOE+00
- 5. OOOE+00 0. OOOE+00 0. OOOE+00 8.400E+03
- 1. O00E-04
- 3. OOOE+01
- 4. OOOE-01 7. OOOE-01
- 1. OOOE+00 1
4 OOOE+/-OO I 500E+00 4 OOOE-01 2 OOOE-01 2 OOOE-01 5 300E+00
- 1. OOOE+0l
- 0. 00 OE+OO 0.OO00E+00O
- 0. 00OE+0O 0 OOOE+OO 0 OOOE+00 8 400E+03 1 OOOE-04 3 000E+01 4 OOOE-01 7.OOOE-0l 5. OOOE-01 2.500E-01 1.OOOE+00
- 5. OOOE+01 7.O071E+01 0.OOOE+O0 S.
OOOE+OO
- 0. OOOE+OO 0.00 OE+00 0.OOOE+00 0.00 OE+O0
- 0. 000OE+O0 0.0 OOE+OO 0.OOOE+00 0;O~OOE+O0 2.746E-01 not used
>0 shows circular AREA.
NS H(1)
DENSUZ (1)
TPUZ (1)
EPUZ (1)
FCUZ (1)
BUZ (1)
HCUZ (1)
DCNUCC) 1)
DCNUCU(
1,I)
DCNUCS(
1)
ALEACH(
1)
SOLUBK) 1)
INHALR MLINH ED SHF3 SHFI FIND FOTD FS PADSHAPE(
1.)
RADSHAPE) 2)
RADSHAPE(
3)
RADSHAPE(
4)
RADSHAPE) 5)
PADSHAPE) 6)
RADSHAPE) 7)
RAD_SHAPE) 8)
RADSHAPE) 9)
RADSHAPE(i0)
RADSHAPE(ll)
RAD_SHAPE(12)
Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer annular annular annular annular annular annular annular annular annular annular annular annular radius radius radius radius radius radius radius radius radius radius radius radius (n),
(m),
(mn),
(in),
(in),
(in),
(ms),
(in),
(in),
(in),
Wm)
(m),
ring ring ring ring ring ring ring ring ring ring ring ring I:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
not not not not not not not not not not not not used used used used used used used used used used used used
RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:56 Page 5
Summary : Subsistence FarmerCT4_r0a_0m File
- C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCT4_ROAOM.RAD Site-Specific Parameter Summary (continued)
Parameter R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R018 R01S R018 R01O R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R19B R19B R19B R19B R19B R19B Fractions Ring 1
Ring 2
Ring 3
Ring 4
Ring 5
Ring 6
Ring 7
Ring 8
Ring 9
Ring T0 Ring 11 Ring 12 of annular areas within AREA:
Fruits, vegetables and'grain consumption (kg/yr)
Leafy vegetable consumption (kg/yr)
Milk consumption (L/yr)
Meat and poultry consumption (kg/yr)
Fish consumption (kg/yr)
Other seafood consumption (kg/yr)
Soil ingestion rate (g/yr)
Drinking water intake (L/yr)
Contamination fraction of drinking water Contamination fraction of household water Contamination fraction of livestock water Contamination fraction of irrigation water Contamination fraction of aquatic food Contamination fraction of plant food Contamination fraction of meat Contamination fraction of milk Livestock fodder intake for meat (kg/day)
Livestock fodder intake for milk (kg/day)
Livestock water intake for meat (L/day)
Livestock water intake for milk (L/day)
Livestock soil intake (kg/day)
Mass loading for foliar deposition (g/m**3)
Depth of soil mixing layer (m)
Depth of roots (m)
Drinking water fraction from ground water Household water fraction from ground water Livestock water fraction from ground water Irrigation fraction from ground water Wet weight crop yield for Non-Leafy (kg/m**2)
Wet weight crop yield for Leafy (kg/m**2)
Wet weight crop yield for Fodder (kg/m**2)
Growing Season for Non-Leafy (years)
Growing Season for Leafy (years)
Growing Season for Fodder (years) user Input not used not used not used not used not used not used not used not used not used not used not used not used 1.600E+02 1.400E+01 9.200E+01 6.300E+01 5.400E+00 9.OOOE-01 3.650E+01 5.100E+02 1.00OE+00 not used 1.00OE+00 1.000E+00 5.OOOE-01 1-i 1-i 1-i 6.800E+01 5.500E+01 5.DOOE+01 1.600E+02 5.000E-01 1.OOOE-04 1.500E-01 9.OOOE-01 1.000E+00 not used 1.00OE+00 1.OOOE+00 7.OOOE-01 1.500E+00 1.100E+00 1.700E-01 2.500E-01 8.000E-02 Default 1.000E+00 2.732E-01 0.OOOEE+00
- 0. OOOE+00 0.00 E+00
- 0. 00OE+00
- 0. 000E+O0 0 O.OOE+00 0 O.OOE+00
- 0. 000E+00 0.OOOE+OO
- 0. 000E+00
- 0. 000E+00
- 1. 600E+02
- 1. 400E+01
- 9. 200E+01 6.300E+01 5.400E+00 9 DOOE-01
- 3. 650E+01
- 5. 100E+02
- 1. 00OE+00
- 1. 000E+00 1.OOOE+00
- 1. OOOE+00 5.OOOE-01
-i 1-I 1-i
- 6. 800E+01
- 5. 500E+01 5.000E+01 1.600E+02 5.OOOE-O0 1.OOOE-04 1.500E-01 9.OOOE-01 1.OOOE+00 L 1.OOOE+00 1.OOOE+00 1.OOOE+00 7.OOOE-01 1.500E+00 1.100E+00 1.700E-01 2.500E-01 8.OOOE-02 Used by RESRAD (If different from user input)
Parameter Name FRACA(
1)
FRACA(
2)
FRACA(
3)
FRACA) 4)
FRACA(
5)
FRACA) 6)
FRACA(
7)
FRACA(
8)
FRACA(
9)
FRACA(10)
FRACA(II)
FRACA(12)
DIET (1)
DIET(2)
DIET(3)
DIET(4)
DIET(5)
DIET(6)
SOIL DWI FDW FHHW FLW FIRW FR9 FPLANT FMEAT FMILK LFI5 LFI6 LWI5 LWI6 LSI MLFD DM DROOT FGWDW FGWHH FGWLW FGWIR YV(l)
YV(2)
YV(3)
TE(l)
TE(2)
TE(3) 0.250E-01 0.250E-02 0.250E-02
RFSRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:56 Page 6
Summary Subsistence FarmerC14_rOaOm File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC14_ROA_0M.RAD Site-Specific Parameter Summary (continued)
Menu Parameter R19B R19B R19B R19B R19B R19B R19B R19B R19B C14 C14 C14 C14 C14 C14 C14 C14 C14 STOR STOR STOR STOR STOR STOR STOR TOPR STOR STOR R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 R021 Translocation Factor for Non-Leafy Translocation Factor for Leafy Translocation Factor for Fodder Dry Foliar Interception Fraction for Non-Leafy Dry Foliar Interception Fraction for Leafy Dry Foliar Interception Fraction for Fodder Wet Foliar Interception Fraction for Non-Leafy Wet Foliar Interception Fraction for Leafy Wet Foliar Interception Fraction for Fodder Weathering Removal Constant for Vegetation C-12 concentration in water (g/cm**3)
C-12 concentration in contaminated soil (g/g)
Fraction of vegetation carbon from soil Fraction of vegetation carbon from air C-14 evasion layer thickness in soil (m),
C-14 evasion flux rate from soil (1/sec)
Cý12 evasion flux rate from soil (1/sec)
Fraction of grain in beef cattle feed Fraction of grain in milk cow feed Storage times of contaminated foodstuffs (days):
Fruits, non-leafy vegetables, and grain Leafy vegetables Milk Meat and poultry Fish Crustacea and mollusks, Well water Surface water Livestock fodder Thickness of building foundation (m)
Bulk density of building foundation (g/cm**3)
Total porosity of the cover material Total porosity of the building foundation Volumetric water content of the cover material Volumetric water content of the foundation Diffusion coefficient for radon gas (m/sec):
in cover material.
in foundation material in contaminated zone soil Radon vertical dimension of mixing (m)
Average building air exchange rate (1/hr)
Height of the building (room)
(m)
Building interior area factor Building depth below ground surface (m)
Emanating power of Rn-222 gas Emanating power of Rn-220 gas I.
I.
User Input Default 1.000E-01 1.OOOE-01 1.000E+00 1.OOOE+00 1.000E+00 1.OOOE+00 2.500E-01 2.50OE-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.500E-01 2.OOOE+01 2.OOOE+01 2.OOOE-05 2.OOOE-05 3.OOOE-02 3.OOOE-02 2.OOOE-02 2.000E-02 9.800E-01 9.800E-01 3.OOOE-01 3.000E-01 7.OOOE-07 7.000E-07 1.000E-10 1.OOOE-10 8.00CE-01 8.000E-01 2.000E-01 2.OOOE-01 1.400E+01 1.400E+01 1.OOOE+00 1.0005+00 1.000E+00 1.0005+00 2.OOOE+01 2.OOOE+01 7.000E+00 7.OOOE+00 7.000E+00 7.000E+00 1.OOOE+00 1.000E+00 1.000E+00 1.OOOE+00 4.500E+01 4.500E+01 not used 1.500E-01 not used 2.400E+00 not used 4.OOOE-01 not used 1.000E-01 not used 5.000E-02 not used 3.000E-02 not used 2.OOOE-06 not used 3.OOOE-07 not used 2.000E-06 not used 2.000E+00 not used 5.000E-01 not used 2.500E+00 not used 0.000E+00 not used I.-1.000E+00 not used 2.500E-01 not used I 1.500E-01 32 I
Used by RESRAD Par (If different from user input)
N TIV(
TIV(
- -TIV(
-RDRY RDRY RDRY
-RWET
-RWET RWET WLAM C12W C12C CSOI CAIR DMC EVSN REVS AVFG AVFG STOR STOP STOR STOR STOR STOR STOR.
STOR.
STOR FLOO0 DENS:
TPCV TPFL
-- PH20(
PH20]
DIFC*
DIFF]
DIFC
-MIX
---REXG
-HRM FAI DMFL EMANI EMANI NPTS ameter ame 1) 2)
3)
(1)
(2)
(3)
(1)
(2)
(3)
TTR Z
L N
4 5
T (1)
T(2)
T (3)
T (4)
T (5)
T (6)
T(7)
_T (8)
T (9)
R1 FL CV FL V
~(2)
.TITL I Number of graphical time points
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:56 Page 7
Summary Subsistence FarmerC14_r~aOm File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\SFCl4_R0AOM.RAD Site-Specific Parameter Summary (continued)
User I
I Used by RESRAD Parameter Input I
Default I (If different from user input)
Name Parameter L M n
TITL Maximum number of integration points for dose 217 j
LYMAX TITL Maximum *number of integration points for risk I
257 I
I IKYMAX I
I Summary of Pathway Selections Pathway User Selection 1 --
external gamma active 2 --
inhalation (w/o radon) active 3 --
plant ingestion active 4 --
meat ingestion active 5 --
milk ingestion active 6 --
aquatic foods active 7 --
drinking water active 8 --
soil ingestion active 9 --
radon suppressed Find peak pathway doses active
- RE8RAD, Version 6.5 ThLimit = 30 days 05/04/2012 12:56 Page 8
Summary : Subsistence FarmerC14_r0a_0m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\SFC14 RCA CM.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area:
Thickness:
Cover Depth:
50.00 square meters 1.00 meters 0.00 meters C-14
- 1. 000E+00 Total Dose TDOSE(t),
mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years):
0.000E+00 1.00IE+00 3.C00E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.0OCE+03 TDOSE(t):
2.137E-03 2.547E-06 2.395E-12 8.669E-05 8.632E-05 0.OO0E+00 C.0OOE+00 0.000E+00 M(t):
8.549E-05 1.019E-07 9.579E-14 3.468E-06 3.453E-06 C.C0CE+00 0.C00E+00 0.000E+00 Maximum TDOSE(t):
2.137E-03 mrem/yr at t = O.000E+00 years
RESRAD, Version 6.5 T1/2 Limit ='30 days 05/04/2012 12:56 Page 9
Summary : Subsistence FarmerC14_r0a 0m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCl4 RCA _M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0,000E+00 years Water Independent Pathways (Inhalation excludes radon)
Radio-Nuclide C-14 Total Ground mrem/yr fract.
8.386E-07 0.0004 8.386E-07 0.0004 Inhalation mrem/yr fract.
6.099E-06 0.0029 6.099E-06 0.0029 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
2.023E-03 0.9467 2.023E-03 0.9467 Meat mrem/yr fract.
7.941E-05 0.0372 7.941E-05 0.0372 Milk mrem/yr fract.
2.722E-05 0.0127 2.722E-05 0.0127 Soil mrem/yr frac 4.227E-07 C.0C 4.227E-07 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Dependent Pathways Water Fish Radon Plant Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OCCE+00 0.0000 0.000E+00 C.0000 0.0C0E+00 0.000C 0.C00E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Meat Milk mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 2.137E-03 1.0C 2.137E-03 1.0C
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:56 Page 10 Summary : Subsistence Farmer C14 r~a Om File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCI4 ROA 0M-RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and As mrem/yr and Fraction of Total Dose At t = 1.OOOE+00 years, Pathways (p)
Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide C-14 Total mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
8.290E-10 0.0003 6.029E-09 0,0024 0.DOOE+00 0.0000 2.353E-06 0.9239 1.437E-07 0.0564 8.290E-10 0.0003 6.029E-09 0.0024 0.OOOE+00 0.0000 2.353E-06 0.9239 1.437E-07 0.0564 mrem/yr fract.
mrem/yr frac 4.274E-08 0.0168 4.274E-08 0.0168 4.178E-10 D.OC 4.17BE-10O0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.OO0E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 2.547E-06 1.OC 2.547E-06 1.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:56 Page 11 Summary Subsistence Farmer C14_r0a_Om File C:\\RESRADFAOMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\SFC14_ROAOMRAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 7.784E-16 0.0003 Total 7.784E-16 0.0003 Inhalation mrem/yr fract.
5.661E-15 0.0024 5.661E-15 0.0024 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
2.212E-12 0.9237 2.212E-12 0,9237 Meat mrem/yr fract.
1.356E-13 0.0566 1.356E-13 0.0566 Milk mrem/yr fract.
4.026E-14 0.0168 4.026E-14 0.0168 Soil mrem/yr frac 3.923E-16 0.OC 3.923E-16 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+00 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Fish mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 O.O00E+00 0.0000 Plant
.mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 2.395E-12 1.OC 2.395E-12 1.OC
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:56 Page 12 Summary Subsistence FarmerC14 r0aeOm File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCl4_ROAOM.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.00OE+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Inhalation Radon Plant Meat mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.OOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.O0OE+00 0.0000 0.000E+00 0.0000 Milk Soil mrem/yr fract.
mrem/yr frac 0.OOOE+00 0.0000 "0.OOOE+00 0.0000 O.000E+00 0.OC O.O00E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000+E01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 6.453E-05 0.7444 2.200E-05 0.2537 0o.000E+00 0.0000 1.137E-07 0.0013 1.164E-08 0.0001 3.943E-08 0.0005 Total 6.453E-05 0.7444 2.200E-05 0.2537 0.000E+00 0.0000 1.137E-07 0.0013 1.164E-08 0.0001 3.943E-08 0.0005 All Pathways mrem/yr frac 8.669E-05 1.OC 8.669E-05 1.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:56 Page 13 Summary
- Subsistence FarmerC14_r0a_0m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC14_R0A OM.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radio-Nuclide mrem/yr fract.
mrem/yr fract.
C-14 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.000E+00 0.0C 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOOE+01 years Water Dependent Pathways Water Fish Radon Plant Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 6.425E-05 0.7443 2.190E-05 0.2538 0.000E+00 0.0000 1.132E-07 0.0013 Total 6.425E-05 0.7443 2.190E-05 0.2538 0.000E+00 0.0000 1.132E-07 0.0013 Meat mrem/yr fract.
1.159E-08 0.0001 1.159E-08 0.0001 Milk mrem/yr fract.
3.926E-08 0.0005 3.926E-08 0.0005 All Pathways mrem/yr frac 8.632E-05 1.0C 8.632E-05 1.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 Ts Limit = 30 days 05/04/2012 12:56. Page 14 Summary : Subsistence Farmer C14 r~a 0m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC14_RCA_0M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.COCE+00 0.0000 Total 0.000E+00 0.0000 Inhalation Radon Plant mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
O.CCCE+00 0.0000 C.000E+00 0.0000 C.0C0E+00 0.0000 0.000E+00 0.0000 C.00CE+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
C.000E+00 0.0000 0.00E+00 0.0000 Soil mrem/yr frac 0.000E+00 C.0C 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.0O0E+00 0.0000 0.CC0E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac O.O00E+00 C.OC O.O00E+00 C.OC
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:56 Page 15 Summary Subsistence FarmerC14_r0a_Om File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCl4_ROA_OM.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide C-14 Total mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr frac 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOOE+02 years Water Dependent Pathways 0.OOOE+00 0.OC 0.OOOE+00 0.OC Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.0O0E+00 0.0000 Total 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0.0C 0.OOOE+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T, Limit = 30 days 05/04/2012 12:56 Page 16 Summary Subsistence Farmer C14 r0a Om File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\Cl4\\SFCI4_R0A 0M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)
Radio-Nuclide C-14 Total Ground Inhalation Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t
= 1.OOOE+03 years Water Dependent Pathways Water Fish Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.OO0E+00 0.0C 0.000E+00 0.OC Radio-Nuclide C-14 Total All Pathways mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC
- Sum, of all water independent and dependent pathways.
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:56 Page 17 Summary : Subsistence Farmer C14 r0a 0m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC14_R0A 0M.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in'Years (mrem/yr)/(pCi/g)
(i)
(j)
Fraction 0.000E+00 1.OOOE+00 3.000E+00 1.000E+01 3.OOOE+01 1.000E+02 3.000E+02 1.000E+03 C-14 C-14 1.000E+00 2.137E-03 2.547E-06 2.395E-12 8.669E-05 8.632E-05 7.006E-45 0.000E+00 0.000E+00 The DSR includes contributions from associated (half-life
- 30 days) daughters.
Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit 2.500E+01 mrem/yr Nuclide Wi) t= 0.000E+00 1.000E+00 C-14 1.170E+04 9.815E+06
- At specific activity limit
- 3. 000E+00
- 4. 455E+12
- 1. 000E+01
- 2. 884E+05
- 3. 000E+01
- 2. 896E+05 1.000E+02 3.OO0E+02 1.000E+03
- 4.455E+12
- 4.455E+12
- 4.455E+12 Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose = 0.000E+00 years Nuclide Initial Wi)
(pCi/g)
C-14 1.000E+00 tmin (years)
- 0. 000E+00 DSR(i,tmin) G(i,tmin) DSR(i,tmax)
(pCi/g) 2.137E-03 1.170E+04 2.137E-03 G6(i, tmax)
(pCi/g)
- 1. 170E+04
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:56 Page 18 Summary Subsistence Farmer C14 r~a 0m File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC14 R0A 0M.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
DOSE(j,t),
mrem/yr (j)
(i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.O0OE+03 C-14 C-14 1.000E+00 2.137E-03 2.547E-06 2.395E-12 8.669E-05 8.632E-05 0.000E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
S(j,t), pCi/g (j)
(i) t= 0.000E+00 1.000E+00 3.O00E+00 1.O00E+01 3.00E+01 1.000E+02 3.000E+02 1.000E+03 C-14 C-14 1.000E+00 1.0O0E+00 9.905E-04 9.335E-10 4.967E-31 0.C00E+00 0.0C0E+00 0.000E+00 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
RESCALC.EXE execution time = 1051.29 seconds
DOSE: C-14, Component Pathways 0)
L.
E 7,OOE-O5 6.OOE-05 5,0OE-05 4,OOE-05 3.00E.-05 2,OOE-05 I.OOE-05 O.OOE+01 1
10 100 Years 1000 External
-Ar-Plant (Water Independent)
Inhalation 3
Meat (Water Independent)
Radon (Water Independent)
--)K-Milk (Water Independent)
Soil Ingest Drinking Water 0-Fish Radon (Water Dependent)
Milk (Water Dependent)
J Plant (Water Dependent)
-A-- Meat (Water Dependent)
CARESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C1 4\\SFC1 4_ROA_0M.RAD 05/0412012 12:56 GRAPHICS.ASC
- RESRAD, Version 6.5 TV' Limit = 30 days 05/04/2012 12:51 Page I
Summary
- Subsistence FarmerC14 r0b_5m File C:\\RESPADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCI4_ROC_5M.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
Site-Specific Parameter Summary..........................
Summary of Pathway Selections Contaminated Zone and Total Dose Summary.................
Total Dose Components Time = 0.000E+00.....................................
Time = 1.000E+00 Time = 3.000E+00 Time = 1.000E+01....................................
Time = 3.000E+01 Time = 1.000E+02 Time = 3.OOOE+02 Time = 1.000E+03.
Dose/Source Ratios Summed Over All Pathways...............
Single Radionuclide Soil Guidelines......................
Dose Per Nuclide Summed Over All Pathways................
Soil Concentration Per Nuclide...........................
2 3
7 8
9 10 11 12 13 14 15 16 17 17 18 18 ytA
RESRAD, Version 6.5 T;1 Limit ý 30 days 05/04/2012 12:51 Page 2
Summary Subsistence FarmerC14_rOb_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCI4_ROC_5M.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 12 & FGR 11 Menu Parameter i
i B-1 B-1 B-1 D71 D-1 D-34 D-34 D-34 D-34 D-5 D-5 D-5 DCF's for external ground radiation, (mrem/yr)/(pCi/g)
C-14 (Source: FGR 12)
Dose conversion factors for inhalation, mrem/pCi:
C-14(p)
(Class: ORGANIC)
C-14(g)
(Class: C02)
Dose conversion factors for ingestion, mrem/pCi:
C-14 Food transfer factors:
, plant/soil concentration ratio, dimensionless C-14
, beef/livestock-intake ratio, (pCi/kg)/(pCi/d)
, milk/livestock-intake ratio, (pCi/L)/(pCi/d)
Current Value#
1.345E-05 2.090E-06 2.350E-08 2.090E-06 5.500E+00 3.100E-02 1.200E-02 5.000E+04 9.100E+03
.Base Parameter Case*
Name 1.345E-05 DCFI(
1) 2.090E-06 DCF2(
1) 2.350E-08 CI4GInhDCF 2.090E-06 DCF3(
1) 5.500E+00 RTF(
1,1) 3.100E-02 RTF(
1,2) 1.200E-02 RTF(
1,3) 5.000E+04 BIOFAC(
1I 9.100E+03 BIOFAC(
I Bioaccumulation factors, fresh water, L/kg:
, fish C-14
, crustacea and mollusks
,1)
,2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See
- Base Case means Default.Lib w/o Associate Nuclide contributions.
ETFG table in Ground Pathway of Detailed Report.
- RESRAD, Version 6.5 THj Limit = 30 days 05/04/2012 12:51 Page 3
Summary : Subsistence Farmer C14 rOb_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\SFC14_ROC_5M.RAD Site-Specific Parameter Summary User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input)
Name R011 Area of contaminated zone (m**2) 5.000E+01 1.OOOE+04 AREA R011 Thickness of contaminated zone (m) 1.OOOE+00 2.000E+00 THICKO R011 Fraction of contamination that is submerged 0.000E+00 0.OOOE+00 SUBMFRACT R011 Length parallel to aquifer flow (m) 1.000E+02 1.OOOE+02 LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 3.000E+01 BRDL R011 Time since placement of material (yr) 0.000+E00 0.000E+00 TI R011 Times for calculations (yr) 1.000E+00 1.000E+00
-TT(
2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 T(
3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 T(4)
R011 Times for calculations (yr) 3.O00E+01 3.000E+01 T(
5)
R011 Times for calculations (yr) 1.000E+02 1.OOOE+02
-TT(
6)
R011 Times for calculations (yr) 3.0O0E+02 3.000E+02 T(
7)
R011 Times for calculations (yr)
.o000E+03 1.000E+03 T(
8)
R011 Times for calculations (yr) not used 0.000E+00 T(9)
R011 Times for calculations (yr) not used 0.000E+00 T(10)
R012 Initial principal radionuclide (pCi/g):
C-14 1.000E+00 0.OOOE+00 Sl(l)
R012 Concentration in groundwater (pCi/L) :
C-14 not used 0.000E+00 Wl(I 1)
R013 Cover depth (m) 5.OOOE+00 0.000E+00 COVERO R013 Density of cover material (g/cm**3) 1.500E+00 1.500E+00 DENSCV R013 Cover depth erosion rate (m/yr) 1.000E-03 1.000E-03 VCV R013 Density of contaminated zone (g/cm**3) 1.500E+00 1.500E+00 DENSCZ R013 Contaminated zone erosion rate (m/yr) 1.000E-03 1.000E-03 VCZ R013 Contaminated zone total porosity 4.OOOE-01 4.000E-01 TPCZ R013 Contaminated zone field capacity 2.000E-01 2.000E-01 FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 1.000E+01 1.OOOE+01 HCCZ R013 Contaminated zone b parameter 5.300E+00 5.300E+00 BCZ R013 Average annual wind speed (m/sec) 2.000E+00 2.000E+00 WIND R013 Humidity in air (g/m**3) not used-8.000E+00 HUMID R013 Evapotranspiration coefficient 5.000E-01 5.000E-01 EVAPTR R013 Precipitation (m/yr) 1.000E+00 1.000E+00 PRECIP R013 Irrigation (m/yr) 2.OOOE-01 2.000E-01 RI R013 Irrigation mode overhead overhead IDITCH R013 Runoff coefficient 2.000E-01 2.000E-01 RUNOFF R013 Watershed area for nearby stream or pond (m**2) 1.000E+06 1.OOOE+06 WAREA R013 Accuracy for water/soil computations 1.OOOE-03 1.OOOE-03 EPS R014 Density of saturated zone (g/cm**3) 1.500E+00 1.500E+00 DENSAQ R014 Saturated zone total porosity 4.000OE-01 4.000E-01 TPSZ R014 Saturated zone effective porosity 2.000E-01 2.OOOE-01 EPSZ R014 Saturated zone fieldcapacity 2.000E-01 2.000E-01 FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 1.000E+02 1.000E+02 HCSZ R014 Saturated zone hydraulic gradient 2.OOOE-02 2.OOOE-02 HGWT R014 Saturated zone b parameter 5.300E+00 5.300E+00 BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 VWT R014 Well pump intake depth (m below water table)-
1.000E+01 1.000E+01....
DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB)
ND ND MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 UW I
~~I
RESRAD, Version 6.5 T11 Limit = 30 days 05/04/2012 12:51 Page 4
Summary Subsistence Farmer C14 rOb 5m File
- C:\\RESPAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC14_ROC_5M.RAD Site-Specific Parameter Summary (continued)
Parameter R015 R015 R015 R015 R015 R015 R015 R015 R016 R016 R016 R016 R016 R016 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 Number Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
of unsaturated zone strata zone 1, thickness (m) zone 1, soil density (g/cm**3) zone 1, total porosity zone 1, effective porosity zone 1, field capacity zone 1, soil-specific b parameter zone 1, hydraulic conductivity (m/yr)
Distribution coefficients for C-14 Contaminated zone (cm**3/g)
Unsaturated zone 1 (cm**3/g)
Saturated zone (cm**3/g)
Leach rate (/yr)
Solubility constant Inhalation rate (m**3/yr)
Mass loading for inhalation (g/m**3)
Exposure duration Shielding factor, inhalation Shielding factor, external gamma Fraction of time spent indoors Fraction of time spent outdoors (on site)
Shape factor flag, external gamma Radii of shape factor array (used if FS = -1):
1 4.
4.
2.
2.
5.
1.
1*.
1.
5.
0.
0.
8.
1.
3.
4.
7.
6.
8.
1.
User Input
.000E+00
.500E+00
.O0E-01 000E-01
.OOE-01 300E+00 OOOE+01 OOOE+00 000E+00 000E+00 000E+00 000E+00 400E+03 000E-04 OOOE+01 0OOE-01 000E-01 833E-01 330E-02 000E+00 2
2 1
0 0
0 0
0 8
1 3
4 7
5 2
1 Default 4.OOOE+00 1.500E+00 4,000E-01
.000E-01 2.000E-01 5.300E+00 10006+01
).OOOE+00 0.000E+00 0.OOOE+00 0.000E+00
.000E+00
.400E+03 1000E-04
.000E+01
.000E-01 000E-01
.000E-01
.500E-01 OOOE+00 Used by RESRAD (If different from user input) 2.746E-01 not used
>0 shows circular AREA.
Parameter Name NS H(1)
DENSUZ(1)
TPUZ(1)
EPUZ(1)
FCUZ(1)
BUZ(1)
HCUZ(1)
DCNUCC(
1)
DCNUCU(
1,1 DCNUCS(
1)
ALEACH(
1)
SOLUBK(
1)
INHALR MLINH ED SHF3 SHF1 FIND FOTD FS
[)
Outer annular radius Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer annular annular annular annular annular annular annular annular annular annular annular radius radius radius radius radius radius radius radius radius radius radius (in),
(in),
(in),
(in),
(i),
(in),
(in),
(in),
(in),
ring ring ring ring ring ring ring ring ring ring ring ring 1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
not used not used not used not used not used not used not used not used not used not used not used not used 5.000E+01 7.071E+01 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.006E+00 0O006E+00 0,000E+00 0.006E+00 0.O00E+00 0.O00E+00 RAD SHAPE(
1)
RAD SHAPE(
2)
RAD_SHAPE(
3)
RADSHAPE(
4)
RADSHAPE(
5)
RAD SHAPE(
6)
RAD SHAPE(
7)
RAD SHAPE(
8)
RAD SHAPE(
9)
RAD SHAPE (10)
RAD SHAPE(11)
RADSHAPE(12)
- RESPAD, Summary File Version 6.5 Ti Limit = 30 days 05/04/2012 12:51 Page 5
Subsistence Farmer C14 rOb 5m C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\SFC14_R0C_5M.RAD Site-Specific Parameter Summary (continued)
Menu R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R018 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R019 R19B R19B R19B R19B R19B R19B Parameter Fractions Ring 1
Ring 2
Ring 3
Ring 4
Ring 5
Ring 6
Ring 7
Ring 8
Ring 9
Ring 10 Ring 11 Ring 12 of annular areas within AREA:
Fruits, vegetables and grain consumption (kg/yr)
Leafy vegetable consumption (kg/yr)
Milk consumption (L/yr)
Meat and poultry consumption (kg/yr)
Fish consumption (kg/yr)
Other seafood consumption (kg/yr)
Soil ingestion rate (g/yr)
Drinking water intake (L/yr)
Contamination fraction of drinking water Contamination fraction of household water Contamination fraction of livestock water Contamination fraction of irrigation water Contamination fraction of aquatic food Contamination fraction of plant food Contamination fraction of meat Contamination fraction of milk Livestock fodder intake for meat (kg/day)
Livestock fodder intake for milk (kg/day)
Livestock water intake for meat (L/day)
Livestock water intake for milk (L/day)
Livestock soil intake (kg/day)
Mass loading for foliar deposition (g/m**3)
Depth of soil mixing layer (m)
Depth of roots (m)
Drinking water fraction from ground water Household water fraction from ground water Livestock water fraction from ground water Irrigation fractibn from ground water Wet weight crop yield for Non-Leafy (kg/m**2)
Wet weight crop yield for Leafy (kg/m**2)
Wet weight crop yield for Fodder (kg/m**2)
Growing Season for Non-Leafy (years)
Growing Season for Leafy (years).
Growing Season for Fodder (years)
User Input not used not used not used not used not used not used not used not used not used not used not used not used 1.600E+02 1.400E+01 9.200E+01 6.300E+01 5.400E+00 9.OD0E-01 3.650E+01 5.100E+02 1.000E+00 not used 1.OOOE+00 1.OOOE+00 5.OOOE-01 j-1 1-i I-i 6.800E+01 5.500E+01 5.000E+01 1.600E+02 5.000E-01 1.000E-04 1.500E-01 9.000E-01 1.000E+00 not used 1.000E+00 1.000E+00 7.000E-01 1.500E+00 1.100E+00 1.700E-01 2.500E-01 8.000E-02 1-2 0
0 0
0 0
0 0
0 0
0 9
6 5
5 5
9 7
2
-I
-I
-I 6C 5C 1~
16 13 15 1-16 j2 8s Default (If 1.OOOE+00
.732E-01
.OOOE+00
).O00E+O0 3.000E+00 3.000E+00
'.000E+00
'.000E+00
'.000+00I 3.000E+00
.OOOE+00
.*.OE+00
.600E+02
.400E+01
.200E+01
.300E+01
.400E+00
- .000E-01
.650E+01 3.100E+02
.400E+00
.000E+00
- .000E+00
.OOOE+00
.OOOE-01
.800E+01 5.500E+01 5.00E+01
- .600E+02
. 000E-01
. 000E-04
.500E-01
'.000E-01
.000E+00
.000E+00
.000E+00
.000E+00
.000E-01
.500E+00
.100E+00
.700E-01
.500E-01
.000E-02 Used by RESRAD different from user input) 0.250E-01
- 0. 250E-02 0.250E-02 Parameter Name FRACA) 1)
FRACA) 2)
FRACA(
3)
FRACA) 4)
FRACA) 5)
FR.ACA) 6)
FRACA) 7)
FRACA) 8)
FRACA) 9)
FRACA(10)
FRACA(lI)
FRACA(12)
DIET(l)
DIET(2)
DIET (3)
DIET(4)
DIET(5)
DIET(6)
SOIL DWI FDW FHHW FLW FIRW FR9 FPLANT FMEAT FMILK LFI5 LFI6 LWI5 LWI6 LSI MLFD DM DROOT FGWDW FGWHH FGWLW FGWIR YV(1)
YV(2)
YV(3)
TE 1i)
TE(2)
TE(3)
RESRAD, Version 6.5 T1 Limit = 30 days 05/04/2012 12:51 Page 6
Summary Subsistence FarmerC14_rOb_5m File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\SFCI4_ROC_5M.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter menu Parameter Input Default (If different from user input)
Name R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 TIV(l)
R19B Translocation Factor for Leafy 1.OOOE+00 1.000E+00 TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 2.500E-01 2.500E-01 RDRY(l)
R19B Dry Foliar Interception Fraction for Leafy 2.500E-01 2.500E-01 RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 2.500E-01 2.500E-01 RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 2.500E-01 2.500E-01 RWET(l)
R19B Wet Foliar Interception Fraction for Leafy 2.500E-01 2.500E-01 RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 2.500E-01 2.500E-01 RWET(3)
R19B Weathering Removal Constant for Vegetation 2.000E+01 2.OOOE+01 WLAM C14 C-12 concentration in water (g/cm**3) 2.OOOE-05 2.OOOE-05 j--
C12WTR C14 C-12 concentration in contaminated soil (g/g) 3.000E-02 3.OOOE-02 C12CZ C14 Fraction of vegetation carbon from soil 2.000E-02 2.OOOE-02 CSOIL C14 Fraction of vegetation carbon from air 9.800E-01 9.800E-01 CAIR C14 C-14 evasion layer thickness in soil (m) 3.OOOE-01 I.3.O0OE-01 I DMC C14 C-14 evasion flux rate from soil (1/sec) 7.0OOE-07 7.000E-07 EVSN C14 C-12 evasion flux rate from soil (1/sec) 1.000E-10 1.000E-10 REVSN C14 Fraction of grain in beef cattle feed 8.000E-01 8.000E-01 AVFG4 C14 Fraction of grain in milk cow feed 2.000E-01 2.000E-01 AVFG5 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 STOR T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 STORT(2)
STOR Milk 1.000E+00 1.000E+00 STORPT(3)
STOR Meat and poultry 2.000E+01 2.000E+01 STOR T(4)
STOR Fish 7.000E+00 7.000E+00 STORT(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 STORT(7)
STOR Surface water 1.000E+00 1.000E+00 STORT(8)
STOR Livestock fodder 4.500E+01 4.500E+01 STORT(9)
R021 Thickness of building foundation (m) not used 1.500E-01 FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 DENSFL R021 Total porosity of the cover material not used 4.000E-01 TPCV R021 Total porosity of the building foundation not used 1.000E-01 TPFL R021 Volumetric water content of the cover material not used 5.000E-02 PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 PH20FL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 DIFCV R021 in foundation material not used 3.000E-07 DIFFL R021 in contaminated zone soil not used 2.000E-06 DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 M---
NIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 REXG R021 Height of the building (room)
(m) not used 2.500E+00 HRM R021 Building interior area factor not used 0.000E+00 FAI R021 Building depth below ground surface (m) not used 1-1.000E+00 I---
DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-Oi EMANA(2)
TITL Number of graphical time points 32 NPTS
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:51 Page 7
Summary Subsistence FarmerC14_rOb_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCI4_ROC_5M.RAD Site-Specific Parameter Summary (continued)
I I
User Used by RESRAD Parameter Menu Parameter I
Input I Default (If different from user input) I Name I
I II
.TITL Maximum number of integration points for dose 17 LYMAX TITL Maximum number of integration points for risk 257
[ KYMAX Summary of Pathway Selections Pathway User Selection 1 --
external gamma active 2 --
inhalation (w/o radon)l active 3 -- plant ingestion active 4 --
meat ingestion active 5 --
milk ingestion active 6 --
aquatic foods active 7 --
drinking water active 8 --
soil ingestion active 9 --
radon suppressed
- Find peak pathway doses active
- RESRAD, Version 6.5 Tl Limit = 30 days 05/.04/2012 12:51 Page 8
Summary
- Subsistence Farmer C14 rOb 5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC14_R0C_5M.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area:
Thickness:
Cover Depth:
50.00 square meters 1.00 meters 5.00 meters C-14
- 1. 000E+00 Total Dose TDOSE(t),
mrem/yr Basic Radiation Dose Limit ý 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years):
0.OOOE+00 1.OOOE+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.OOOE+02 1.000E+03 TDOSE(t):
0.000E+00 0.OOOE+00 0.000E+00 1.249E-03 2.163E-03 5.420E-05 1.142E-28 0.000E+00 M(t):
0.000E+00 0.000E+00 0.000E+00 4.997E-05 8.653E-05 2.168E-06 4.569E-30 0.000E+00 Maximum TDOSE(t):
2.165E-03 mrem/yr-at t
=
35.22 +/- 0.07 years Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.522E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
Nuclide C-14 01000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.522E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
Nuclide C-14 1.611E-03 0.7443 5.494E-04 0.2538 0.000E+00 0.0000 2.839E-06 0.0013 2.907E-07 0.0001 9.847E-07 0.0005 Total 1.611E-03 0.7443 5.494E-04 0.2538 0.OOOE+00 0.0000 2.839E-06 0.0013 2.907E-07 0.0001 9.847E-07 0.0005 All Pathways mrem/yr frac 2.165E-03 1.OC 2.165E-03 1.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 Ti, Limit = 30 days 05/04/2012 12:51 Page 9
Surmmary Subsistence Farmer C14_rOb_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\SFC14_ROC_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Radio-Nuclide C-14 Total Ground mrem/yr fract.
0.OOOE+00 0.0000 O.OOOE+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 O.O00E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.0005+00 0.OC 0.0005+0O 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.OOOE+00 years Water Dependent Pathways Water Fish Radio-Nuclide mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.OOOE+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 O.O00E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:51 Page 10 Summary Subsistence Farmer C14 rOb Sm File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\SFC14_ROC_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Meat mrem/yr fract.
0.OOOE+00 0.0000 0.OOE+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.OC 0.OOOE+00 0.0C Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+00 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.OOOE+00 0.0000 Total 0.OOOE+00 0.0000 Fish mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 0.0005+00 0.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T11Limit = 30. days 05/04/2012 12:51 Page 11 Summary : Subsistence FanmerC14_rOb_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCI4_ROC_
5M.RAD.
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOE+00 years Water Independent Pathways (Inhalation excludes radon)
Ground gadio-Nuclide C-14 Total mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.0c Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t
= 3.000E+00 years Water Dependent Pathways Water Fish Radio-Nuclide mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr
- fract, 0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.0C 0.000E+00 0.0C
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T*i Limit = 30 days 05/04/2012 12:51 Page 12 Summary : Subsistence Farmer C14_rOb_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC14_ROC_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.OOOE+00 0.0000 Total 0.OOOE+00 0.0000 Inhalation mrem/yr fract.
0.00OE+00 0.0000 O.O00E+O0 0.0000 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
O.OOOE+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.O00E+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.0C 0.000E+00 0.0C Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr andFraction of Total Dose At t = 1.OOOE+01 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 9.307E-04 0.7450 Total 9.307E-04 0.7450 Fish mrem/yr fract.
3.162E-04 0.2531 3.162E-04 0.2531 Radon mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
1.627E-06 0.0013 1.627E-06 0.0013 Meat mrem/yr fract.
1.655E-07 0.0001 1.655E-07 0.0001 Milk mrem/yr fract.
5.682E-07 0.0005 5.682E-07 0.0005 All Pathways mrem/yr frac 1.249E-03 1.0C 1.249E-03 1.OC
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:51 Page 13 Summary Subsistence FarmerC14_rOb_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCl4_R0C_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Radios Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total D.OOOE+00 0.0000 Inhalation Radon Plant Meat mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Milk Soil
-mrem/yr fract.
mrem/yr frac 0.000E+00 0.0000 0.OOOE+00 0.OC 0.OOOE+00 0.0000 0.000E+00 o.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOOE+01 years Water Dependent Pathways Radio-Nuclide C-14 Total Water mrem/yr fract.
1.610E-03 0.7443 1.610E-03 0.7443 Fish mrem/yr fract.
5.489F-04 0.2538 5.489E-04 0.2538 Radon Plant Meat mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.OOOE+00 0.0000 2.837E-06 0.0013 2.905E-07 0.0001 0.OOOE+00 0.0000 2.837E-06 0.0013 2.905E-07 0.0001 Milk mrem/yr fract.
9.839E-07 0.0005 9.839E-07 0.0005 All Pathways mrem/yr frac 2.163E-03 1.OC 2.163E-03 l.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:51 Page 14 Summary Subsistence Farmer C14_rOb _m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\Cl4\\SFCI4_ROC_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Milk Radio-Nuclide C-14 Total rrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.000E+00 0.0C 0.OOOE+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
C-14 4.030E-05 0.7435 1.380E-05 0.2546 0.OOOE+00 0.0000 7.174E-08 0.0013 7.407E-09 0.0001 2.465E-08 0.0005 Total 4.030E-05 0.7435 1.380E-05 0.2546 0.OOOE+00 0.0000 7.174E-08 0.0013 7.407E-09 0.0001 2.465E-08 0.0005 All Pathways mrem/yr frac 5.420E-05 1.0C 5.420E-05 1.0C
- Sun of all water independent and dependent pathways.
- RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:51 Page 15 Summary Subsistence FarmerCl4.rOb_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFC14_ROC_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t 3.OOOE+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Plant mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Meat Milk mrem/yr fract.
mrem/yr fract.
0.OOOE+00 0.0000 0.OO0E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.OC 0.OOOE+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOOE+02 years Water Dependent Pathways Water Fish Radio-Nuclide C-14 Total mrem/yr fract.
mrem/yr fract.
8.508E-29 0.7449 2.914E-29 0.2551 8.508E-29 0.7449 2.914E-29 0.2551 Radon Plant mrem/yr fract.
mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 Meat mrem/yr
- 0. OOOE+00
- 0. OOOE+00 fract.
0.0000 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 1.142E-28 1.OC 1.142E-28 1.OC
- Sum of-all water independent and dependent pathways.
RESRAD, Version 6.5 TV Limit = 30 days 05/04/2012 12:51 Page 16 Summary SubsistenceFarmer C14_rOb_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCI4_ROC_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.0005+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.00OE+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.OC 0.000E+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Pathways (p)
Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 0.0005+00 0.0000 Total 0.000E+00 0.0000 Fish mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 O.O00E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 0.000E+00 0.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T5 Limit = 30 days 05/04/2012 12:51 Page 17 Summary : Subsistence FarmerC14_r0b_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCl4_ROC_5M.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)
(i)
(j)
Fraction 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 l.000E+02 3.000E+02 1.D00E+03 C-14 C-14 1.000E+00 0.000E+00 0.000E+00 0.000E+00 1.249E-03 2.163E-03 5.420E-05 1.144E-28 0.000E+00 The DSR includes contributions from associated (half-life
- 30 days) daughters.
Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit = 2.500E+01 mrem/yr Nuclide (i)
C-14 t= 0.000E+00
- 4 455E+12 l.000E+00 3.000E+00 l.000E+01 3.000E+01
- 4.455E+12
- 4.455E+12 2.001E+04 1.156E+04 1.000E+02 3.0OOE+02 1.ODDE+D3 4.612E+05
'*4.455E+12 *4.455E+12
- At specific activity limit Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose =
35.22 +/- 0.07 years Nuclide Initial (i)
(pCi/g)
C-14 1.000E+00 tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax)
(years)
(pCi/g) 35.22 +/- 0.07 2.165E-03 1.155E+04 2.165E-03 G (i, tmax)
(pCi/g)
- 1. 155E+04
- RESRAD, Version 6.5 T'i Limit = 30 days 05/04/2012 12:51 Page 18 Summary Subsistence FarmerC14_rOb_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\SFCl4_ROC_5M.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
DOSE(j,t),
mrem/yr (j)
(i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 C-14 C-14 1.000E+00 0.000E+00 0.000E+00 0.000E+00 1.249E-03 2.163E-03 5.420E-05 1.142E-28 0.000E+00 THFý(i) is the thread fraction of the parent nuclide.
Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
S(j,t), pCi/g (j)
(i) t= 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.OOOE+01 1.000E+02 3.000E+02 1.000E+03 C-14 C-14 1.000E+00 1.000E+00 7.598E-01 4.386E-01 6.412E-02 2.636E-04 1.174E-12 1.617E-36 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
RESCALC.EXE execution time =
218.51 seconds
RESRAD, Version 6.5 Ts Limit = 30 days 05/04/2012.12:49 Page Summary Recre d14 r0a 5m File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\RECl4_R0A 5M.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary...
Site-Specific Parameter Summary...........................
Summary of Pathway Selections.............................
Contaminated Zone and Total Dose Summary.................
Total Dose Components Time = 0.000E+00 Time = 1.000E+02 Tim e = 3.000E+02 Time = 1.000E+03....................................
Dose/Source Ratios Summed Over All Pathways..............
Single Radionuclide Soil Guidelines......................
Dose Per Nuclide Summed Over All Pathways.................
Soil Concentration Per Nuclide...........................
L)~-~-
2 3
7 8
9 10 11 12 13 13 14 14 01 1)L (D [
ý_
O.
0 rc
- RESRAD, Version 6.5 Tl Limit = 30 days 05/04/2012 12:49 Page 2
Summary RecreC14'r0a_5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\REC14_ROA_5M.RAD Dose Conversion Factor (and Related) Parameter Summary Dose Library: FGR 12 & FGR 11 menu Parameter A-I A-I B-I B-1 B-I DCF's for external ground radiation, (mrem/yr)/(pCi/g)
C-14 (Source: FGR 12)
Dose conversion factors for inhalation, mrem/pCi:
C-14(p)
(Class: ORGANIC)
C-14(g)
(Class: C02)
Dose conversion factors for ingestion, mrem/pCi:
C-14 Current Value#
1.345E-05 2.090E-06 2.350E-08 2.090E-06 5.500E+00 3.100E-02
'i.200E-02 I.
5.OOOE+04 9.100E+03 Base Parameter Case*
Name 1.345E-05 DCFI(
1) 2.09OE-06 DCF2(
1) 2.350E-08 CI4GInhDCF 2.090E-06 DCF3(
1) 5.500E+00 RTF(
1,1) 3.100E-02 RTF(
1,3) 5.OOOE+04 BIOFAC(
1, 9.100E+03 BIOFAC(
1, D-34 D-34 D-34 D-34 D-5 D-5 D-5 Food C-14 C-14 C-14 transfer factors:
", plant/soil concentration ratio, dimensionless beef/livestock-intake ratio, (pCi/kg)/(pCi/d) milk/livestock-intake ratio, (pCi/L)/(pCi/d)
Bioaccumulation factors, fresh water, L/kg:
, fish C-14
, crustacea and mollusks 1) 2)
- For DCF1(xxx) only, factors are for infinite depth & area.
See
- Base Case means Default.Lib w/o Associate Nuclide contributions.
ETFG table in Ground Pathway of Detailed Report.
- RESRAD, Version 6.5 T's Limit = 30 days 05/04/2012 12:49 Page 3
Summary RecreC14_rOa_5m File C:\\RESPADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\REC14_R0A_5M.RAD Site-Specific Parameter Summary User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input)
Name RR011 Area of contaminated zone (m**2) 5.000E+01 1.000E+04 AREA R011 Thickness of contaminated zone (m) 1.000E+00 2.OOOE+00 THICKO R011 Fraction of contamination that is submerged 0.000E+00 I0.OOE+00 SUBMFRACT R011 Length parallel to aquifer flow (m) 1.000E+02 1.000E+02 LCZPAQ R01l Basic radiation dose limit (mrem/yr) 2.500E+01 3.000E+01 BRDL R011 Time since placement of material (yr) 0.000E+00 0.OOOE+00 TI R011 Times for calculations (yr) 1.000E+02 1.000E+00 T( 2)
P011 Times for calculations (yr) 3.000E+02 3.000E+00 T
3)
R011 Times for calculations (yr) 1.000E+03 1.000E+01 T( 4)
R011 Times for calculations (yr) not used 3.000E+01 T( 5)
R011 Times for calculations (yr) not used 1.000E+02 T( 6)
R011 Times for calculations (yr) not used 3.00QE+02 T( 7)
R011 Times for calculations (yr) not used 1.OOOE+03 T
8)
R011 Times for calculations (yr),
not used 0.OOOE+00 T( 9)
R011 Times for calculations (yr) not used 0.000E+00 T(10)
R012 Initial principal radionuclide (pCi/g):
C-14 1.OOOE+00 0.000E+00 Sl(1)
R012 Concentration in groundwater (pCi/L) :
C-14 not used 0.OOOE+00 W(
1)
A013 Cover depth (m) 5.OOOE+00 0.OOOE+00 COVERO R013 Density of cover material (g/cm**3) 1.500E+00 1.500E+00 DENSCV R013 Cover depth erosion rate (m/yr) 1.000E-03 1.OOOE-03 VCV R013 Density of contaminated zone (g/cm**3).
1.500E+00 1.500E+00 DENSCZ R013 Contaminated zone erosion rate (m/yr) 1.000E-03 1.OOOE-03 VCZ R013 Contaminated zone total porosity 4.OOOE-01 4.OOOE-01 TPCZ R013 Contaminated zone field capacity 2.OOOE-01 2.000E-01 FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 1.000E+01 1.000E+01 HCCZ R013 Contaminated zone b parameter 5.300E+00 5.300+00 0
BCZ R013 Average annual wind speed (m/sec) 2.OOOE+00 2.OOOE+00 WIND R013 Humidity in air (g/m**3) not used 8.000E+00 HUMID R013 Evapotranspiration coefficient 5.000E-01 5.000E-0f EVAPTR R013 Precipitation (m/yr) 1.OOOE+00 1.000E+00 PRECIP R013 Irrigation (m/yr)
I 2.0O0E-01 I2.OOB-01 I RI R013 Irrigation mode overhead overhead IDITCH R013 Runoff coefficient 2.000E-01 2.OO0E-01 RUNOFF R013 Watershed area for nearby stream or pond (m**2) 1.OOOE+06 1.OOOE+06 WAREA R013 Accuracy for water/soil computations 1.000E-03 1.0O0E-03 EPS R014 Density of saturated zone (g/cm**3) 1.500E+00 1.500E+00 DENSAQ R014 Saturated zone total porosity 4.OOOE-01 4.OOE-01 TPSZ R014 Saturated zone effective porosity 2.OOOE-01 2.00DE-01 EPSZ R014 Saturated zone field capacity 2.000E-01 2.000E-01 FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 1.OOOE+02 1.000E+02 HCSZ R014 Saturated zone hydraulic gradient 2.OOOE-02 2.OOE-02 HGWT R014 Saturated zone b parameter 5.300E+00 5.300E+00 BSZ R014 Water table drop rate (m/yr)
I 1.OOOE-03 1.000E-03 VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.OOOE+01 DWIBWT R014 Model: Nondispersion (ND) or'Mass-Balance (MB)
ND ND MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 UW
- RESRAD, Version 6.5 T-Limit = 30 days 05/04/2012 12:49 Page 4
Summary Recre-C14_r0a_5m File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\REC14_R0A_5M.RAD Site-Specific Parameter Summary (continued)
Menu Parameter R015 R015 R015 R015 R015 R015 R015 R015 R016 R016 R016 R016 R016 R016 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 R017 Number Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
Unsat.
of unsaturated zone strata zone 1, thickness (m) zone 1, soil density (g/em**3) zone 1, total porosity zone 1, effective porosity zone 1, field capacity zone 1, soil-specific b parameter zone 1, hydraulic conductivity (m/y Distribution coefficients for C-14 Contaminated zone (cm**3/g)
Unsaturated zone 1 (cm**3/g)
Saturated zone (cm**3/g)
Leach rate (/yr)
Solubility constant Inhalation rate (m**3/yr)
Mass loading for inhalation (g/m**3)
Exposure duration Shielding factor, inhalation Shielding factor, external gamma Fraction of time spent indoors Fraction of time spent outdoors (on site)
Shape factor flag, external gamma Radii of shape factor, array (used if FS =
User Input 1
4.000E+I 1.500E+
4.000E-I
- 2. 000F-2.000E-c 5.300E+(
r) 1.DOOE+(
1.OD0E+(
1.000E+(
- 5. 000E+(
0.0 ODE+(
0.00 0E+(
1.400E+(
1.000E-(
3.00 OE+(
- 4. 000E-(
7.000E-(
0.0D0E+(
3.840E-(
1.DODE+(
-1) :
00 00 01 01 01 00 01 00 00 00 00 00 04 04 01 01 01 00 02 00 4
1 4
2 2
5 1
0 0
0 0
0 3
4 7
5 2
1 Default 4.D0E+00 L.500E+00 4ODOE-01 2.000E-01
.000E-01 5.300E+00 1.00E+0i O.O00E+O0 0.00E+00 0.000E+00 0.OOE+00 0.00E+00
.400E+03 O.O0OE-04
.000E+01 ODOE-01 DO7E-01
.O0E-01
.500E-01 1.00DE+00 Used by RESRAD (If different from user input.)
2.746E-01 not used
>0 shows circular AREA.
Parameter Name NS H(1)
DENSUZ (1)
TPUZ (1)
EPUZ(1)
FCUZ (1)
BUZ)()
HCUZ(1)
DCNUCC(
1)
DCNUCU(
1, DCNUCS(
1)
ALEACH(
1)
SOLUBK(
1)
INHALR MLINH ED SHF3 SHFI FIND FOTD FS 1)
Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer Outer annular annular annular annular annular annular annular annular annular annular annular radius radius radius radius radius radius radius radius radius radius radius Cm),
Cm),
(in),
(in),
(in),
(in),
(W)
(i)
(W)
(i)
(i) ring ring ring ring ring ring ring ring ring ring ring 1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
not used not used not used not used not used not used not used not used not used not used not used not used 5.000E+01 7.071E+01 0.000E+00 0.OOOE+00 0.OO0E+00 0.OOOE+00
- 0. DODE+00 0.000E+00
- 0. 00OE+00 0.DOOE+00 0.000E+00 O. O0E+DO RADSHAPE(
1)
RADSHAPE(
2)
RADSHAPE) 3)
RADSHAPE) 4)
PADSHAPE(
5)
RAD SHAPE(
6)
RADSHAPE) 7)
PAD SHAPE(
8)
RADSHAPE) 9)
RADSHAPE (10)
RADSHAPE (11)
PADSHAPE(12)
R017 I Outer annular radius (m),
ring 12:
RESRAD, Version 6.5 TIs Limit = 30 days 05/04/2012 12:49 Page 5
Summary RecreC14_r~a_5m File C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILESSUM\\C14\\REC14_RCA_5M.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input)
Name R017 Fractions of annular areas within AREA:
R017 Ring 1
not used 1.000E+00 FRACA(
1)
R017 Ring 2
not used 2.732E-01 FRACA(
2)
R017
-Ring 3
not used 0.000E+00 FRACA(
3)
R017 Ring 4
not used 0.000E+00 FRACA(
4)
R017 Ring 5
not used 0.000E+00 FRACA(
5)
R017 Ring 6
not used 0.000E+00 FRACA(
6)
R017 Ring 7
not used 0.000E+00 FRACA(
7)
R017 Ring 8
not used 0.000E+00 FRACA(
8)
R017 Ring 9
not used 0.000E+00 FRACA(
9)
R017 Ring 10 not used 0.000E+00 FRACA(10)
R017 Ring 11 not used 0.000E+00 FRACA(l1)
R017 Ring 12 not used 0.000E+00 FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) not used 1.600E+02 DIET(l)
R018 Leafy vegetable consumption (kg/yr) not used 1.400F+01 DIET(2)
R018 Milk consumption (L/yr) not used 9.200E+01 DIET(3)
R018 Meat and poultry consumption (kg/yr) not used 6.300E+01 DIET(4)
R018 Fish consumption (kg/yr) 0.000E+00 5.400E+00 DIET(5)
R018 Other seafood consumption (kg/yr) 0.000E+00 9.000E-01 DIET(6)
R018 Soil ingestion rate (g/yr) 3.650E+01 3.650E+01 SOIL R018 Drinking water intake (L/yr) 1.960E+01 5.100E+02 DWI R018 Contamination fraction of drinking water 1.000E+00 1.0006+00 FDW R018 Contamination fraction of household water not used 1.000E+00 FHHW R018 Contamination fraction of livestock water not used 1.000E+00 FLW R018 Contamination fraction of irrigation water not used 1.000E+00 FIRW R018 Contamination fraction of aquatic food 5.000E-01 5.000E-01 FR9 R018 Contamination fraction of plant food not used 1-1 FPLANT R018 Contamination fraction of meat not used
-1 FMEAT R018 Contamination fraction of milk not used 1-1 FMILK R019 Livestock fodder intake for meat (kg/day) not used 6.800E+01 LF15 R019 Livestock fodder intake for milk (kg/day) not used 5.500E+01 LF16 R019 Livestock water intake for meat (L/day) not used 5.500E+01 LWI5 R019 Livestock water intake for milk (L/day) not used 1.600E+02 LWI6 R019 Livestock soil intake (kg/day) not used 5.0006-01 LSI R019 Mass loading for foliar deposition (g/m**3) not used 1.000E-04 MLFD R019 Depth of soil mixing layer (m) 1.500E-01 1.500E-01 DM R019 Depth of roots (m) not used 9.000E-01 DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 FGWDW R019 Household water fraction from ground water not used 1.000E+00 FGWHH R019 Livestock water fraction from ground water not used 1.000E+00 FGWLW R019 Irrigation fraction from ground water not used 1.000E+00 FGWIR R19B Wetweight crop yield for Non-Leafy (kg/m**2) not used 7.0006-01.
I YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) not used 1.500E+00 YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) not used 1.100E+00 YV(3)
R19B Growing Season for Non-Leafy (years) not used 1.700E-01 TE(1)
R19B Growing Season for Leafy (years) not used 2.500E-01 TE(2)
R19B Growing Season for Fodder (years) not used 8.000E-02 TE(3)
- RESRAD, Version 6.5 T'i Limit = 30 days 05/04/2012 12:49 Page 6
Summary RecreC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\REC14_R0A_5M.RAD Site-Specific Parameter Summary (continued)
User Used by RESRAD Parameter Menu Parameter Input Default I (If different from user input)
Name R19B jTranslocation Factor for Non-Leafy not used l.0E-01 TIV(l)
R19B Translocation Factor for Leafy not used 1.000E-00 TIV(2)
RI9B Translocation Factor for Fodder not used 1.OOOE+00 TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy not used 2.500E-01 RDRY(l)
R19B Dry Foliar Interception Fraction for Leafy not used 2.500E-01 RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder not used 2.500E-01 RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy not used 2.500E-01 RWET(l)
R19B Wet Foliar Interception Fraction for Leafy not used 2.500E-01 RWET(2)
R19B Wet Foliar Interception Fraction for Fodder not used 2.500E-01 RWET(3)
R19B Weathering Removal Constant for Vegetation not used 2.000E+01 WLAM C14 C-12 concentration in water (g/cm**3) 2.000E-05 2.00DE-05 CI2WTR C14 C-12 concentration in contaminated soil (g/g) 3.000E-02 3.OOOE-02 C12CZ C14 Fraction of vegetation carbon from soil 2.000E-02 2.OOOE-02 CSOIL C14 Fraction of vegetation carbon from air 9.800E-01 9.800E-01 CAIR C14 C-14 evasion layer thickness in soil (m) 3.000E-01 3.000E-01 DMC C14 C-14 evasion flux rate from soil (1/sec) 7.OOOE-07 7,000E-07 EVSN C14 C-12 evasion flux rate from soil (1/sec) 1.000E-10 1.000E-10 REVSN C14 Fraction of grain in beef cattle feed 8.000E-01 8.000E-01 AVFG4 C14 Fraction of grain in milk cow feed 2.000E-01 2.000E-01 AVFG5 STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 STOR T(l)
STOR Leafy vegetables 1.000E+00 1.000E+00 STOR.T(2)
STOR Milk 1.0005+00 1.000E+00 STOR T(3)
STOR Meat and poultry 2.000E+01 I 2.000E+01 STORIT(4)
STOR Fish 7.000E+00 7.OOOE+00 STORPT(5)
STOR Crustacea and mollusks 7.OOOE+00 7.000E+00 STORPT(6)
STOR Well water 1.000E+00 1.000E+00 STORPT(7)
STOR Surface water 1.000E+00 1.000E+00 STORT(8)
STOR Livestock fodder 4.500E+01 4.500E+01 STORPT(9)
R021 Thickness of building foundation (m) not used I1.500E-01 FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 DENSFL R021 Total porosity of the cover material not used 4.OOOE-01 TPCV R021 Total porosity of the building foundation not used 1.000OE-01 TPFL R021 Volumetric water content of the cover material not used 5.000E-02 PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 2---
P2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 DIFCV R021 in foundation material not used 3.OO0E-07 DIFFL R021 in contaminated zone soil not used 2.000E-06 DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 MMIX R021 Average building air exchange rate (I/hr) not used 5<000E-01 REXG R021 Height of the building (room)
(m) not used 2.500E+00 HRM R021 Building interior area factor not used O.OOOE+00 FAI R021 Building depth below ground surface (m)
I not used 1-1.000E+00 I DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 I---
MANA(2)
TITL Number of graphical time points 32 NPTS
- RESRAD, Version 6.5 Tli Limit = 30 days 05/04/2012 12:49 Page 7
Summary :RecreC14_r~a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\REC14_RCA_5M.RAD Site-Specific Parameter Summary (continued)
Menu User I
Input I Default I
Used by RESRAD I (If different from user input)
Parameter Name Parameter
]
I i
n o
TITL Maximum number of integration points for dose 217 f
LYMAX TITL Maximum number of integration points for risk 257 YMA Summary of Pathway Selections Pathway User Selection 1 --
external gamma active 2
inhalation (w/o radon) active 3 -- plant ingestion suppressed 4
meat ingestion suppressed 5 -- milk ingestion suppressed 6 --
aquatic foods active 7 -- drinking water active 8
soil ingestion active 9
radon suppressed Find peak pathway doses active
RESRAD, Version 6.5 T'a Limit = 30 days*
05/04/2012 12:49 Page 8
Sununary : RecreC14_r0a_5m File
- C:\\RESRAD FAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\RE C14 ROA 5M.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area:
Thickness:
Cover Depth:
50.00 square meters 1.00 meters 5.00 meters C-14 I.O00E+00 Total Dose TDOSE(t),
mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t)
= Fraction of Basic Dose Limit Received at Time (t) t (years) :
0.000E+00 1.OOOE+02 3.000E+02 1.000E+03 TDOSE(t) :
0.000E+00 1.549E-06 3.270E-30 0.000E+00 M(t):
0.OOE+00
'6.195E-08 1.308E-31 0.000E+00 Maximum TDOSE(t):
6.193E-05 mrem/yr at t =
35.24 +/- 0.07 years Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.524E+01 years Water Independent Pathways (Inhalation excludes radon)
Ground Inhalation Radon Plant Meat Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
Nuclide C-14 0.00OE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 0.DOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.OC O.00E+00 o.oC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t
= 3.524E+01 years Water Dependent Pathways Water Fish Radon Plant Meat Radio-Nuclide mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
Nuclide C-14 6.193E-05 1.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Total 6.193E-05 1.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 Milk All Pathways mrem/yr fract.
mrem/yr frac 0.000E+00 0.0000 0.000E+00 0.0000 6.193E-05 1,OC 6.193E-05 1.0C
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 Ti Limit = 30 days 05/04/2012 12:49 Page 9
Summary Recre C14 r0a 5m File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\RECl4_RCA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.'0ooE+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.00OE+00 0.0000 Meat mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Soil mrem/yr frac O.O00E+00 0.OC 0.OOOE+00 O.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and As mrem/yr and Fraction of Total Dose At t = 0.OOOE+00 years Pathways (p)
Water Dependent Pathways Water Fish Radio-Nuclide mrem/yr fract.
mrem/yr fract.
C-14 0.000E+00 0.0000 0.OOOE+00 0.0000 Total 0.000E+00 0.0000 0.000E+00 0.0000 Radon mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.000E+00 0.0000.
0.OOOE+00 0.0000 All Pathways mrem/yr frac O.OOOE+00 O.OC 0.000E+00 0.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 VT Limit = 30 days 05/04/2012 12:49 Page 10 Sumitary RecreC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\C14\\REC14_,ROA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Ground Radio-Nuclide mrem/yr fract.
C-14 0.000E+00 0.0000 Total 0.OOOE+00 0.0000 Inhalation Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 o.o0oo 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.OC 0.OOOE+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+02 years Water Dependent Pathways Water Radio-Nuclide mrem/yr fract.
C-14 1.549E-06 1.0000 Total 1.549E-06 1.0000 Fish Radon Plant Meat Milk mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 1.549E-06 1.C 1.549E-06 1.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T;s Limit 30 days 05/04/2012 12:49 Page 11 Summary Recre C14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\REC14_RCA_5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.000E+02 years Water Independent Pathways (Inhalation excludes radon)
Radio-Nuclide C-14 Total Ground Inhalation Radon Plant Meat rsrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.0C 0.OOOE+00 0.OC Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 3.OOOE+02 years Water Dependent Pathways Water Fish Radon Plant Meat Milk All Pathways Radio-Nuclide C-14 Total inrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr fract.
mrem/yr frac 3.270E-30 1.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 3.270E-30 1.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 0.OOOE+00 0.0000 3.270E-30 1.OC 3.270E-30 1.OC
- Sum of all water independent and dependent pathways.
- RESRAD, Version 6.5 T; Limit = 30 days 05/04/2012 12:49 Page 12 Summary RecreC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\RE_
C14 R0A 5M.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.000E+03 years Water Independent Pathways (Inhalation excludes radon)
Radio-Nuclide C-14 Total Ground mrem/yr fract.
0.OOOE+00 0.0000 0.000E+00 0.0000 Inhalation mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Radon Plant Meat mrem/yr fract.
mrem/yr fract.
msrem/yr fract.
0.000E+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.OOOE+00 0.0000 0.000E+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Soil mrem/yr frac 0.OOOE+00 0.OC 0.OOOE+00 0.0C Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.OOOE+03 years WaterDependent Pathways Radio-Nuclide C-14 Total Water mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Fish mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Radon mrem/yr fract.
O.OOOE+00 0.0000 O.OOOE+00 0.0000 Plant mrem/yr fract.
0.000E+00 0.0000 0.000E+00 0.0000 Meat mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 Milk mrem/yr fract.
0.OOOE+00 0.0000 0.OOOE+00 0.0000 All Pathways mrem/yr frac 0.OOOE+00 0.OC 0.000E+00 0.0C
- Sum of all water independent and dependent pathways.
RESRAD, Version 6.5 T1 Limit = 30 days 05/04/2012 12:49 Page 13 Summary. : RecreC14_r0a_5m File
- C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\REC14_R0A_5M.RAD Dose/Source Ratios Summed Over All Pathways Parent and Progeny Principal Radionuclide Contributions Indicated Parent Product Thread DSR(j,t) At Time in Years (mrem/yr)/(pCi/g)
(i)
(j)
Fraction 0.000E+00 1.000E+02 3.000E+02.1.000E+03 C-14 C-14 1.000E+00 0.000E+00 1.549E-06 3.270E-30 0.000E+00 The DSR includes contributions from associated (half-life
- 30 days) daughters.
Single Radionuclide Soil Guidelines G(i,t) in pCi/g Basic Radiation Dose Limit 2.500E+01 mrem/yr Nuclide (i) t= 0.000E+00 1.000E+02 3.000E+02 1.000E+03 C-14
- 4.455E+12 1.614E+07
- 4.455E+12
- 4.455E+12
- At specific activity limit Summed Dose/Source Ratios DSR(i,t) in (mrem/yr)/(pCi/g) and Single Radionuclide Soil Guidelines G(i,t) in pCi/g at tmin = time of minimum single radionuclide soil guideline and at tmax = time of maximum total dose =
35.24 +/- 0.07 years Nuclide Initial tmin DSR(i,tmin) G(i,tmin) DSR(i,tmax) G(i,tmax)
(i)
(pCi/g)
(years)
(pCi/g)
(pCi/g)
C-14 1.000E+00 35.24 +/- 0.07 6.193E-05 4.037E+05 6.193E-05 4.037E+05
RESRAD, Version 6.5 T1/2 Limit = 30 days 05/04/2012 12:49 Page 14 Summary : RecreC14_r0a_Sm File C:\\RESRADFAMILY\\RESRAD\\6.5\\USERFILES\\UM\\CI4\\REC14_R0A_5M.RAD Individual Nuclide Dose Summed Over All Pathways Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
DOSE(j,t),
mrem/yr (j)
(i) t= 0.000E+00 1.000E+0273.000E+02 1.000E+03 C-14 C-14 1.000E+00 0.000E+00 1.549E-06 3.270E-30 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
Individual Nuclide Soil Concentration Parent Nuclide and Branch Fraction Indicated Nuclide Parent THF(i)
S(j,t), pCi/g (j)
(i) t= 0.000E+00 1.000E+02 3.000E+02 1.000E+03 C-14 C-14 1.000E+00 1.000E+00 1.174E-12 1.617E-36 0.000E+00 THF(i) is the thread fraction of the parent nuclide.
RESCALC.EXE execution time 45.47 seconds