ML121800341

From kanterella
Jump to navigation Jump to search

Handouts at the June 29, 2012 NFPA 805 Meeting at the Hq - Item 4
ML121800341
Person / Time
Site: Arkansas Nuclear 
Issue date: 06/28/2012
From: David Bice
Plant Licensing Branch IV
To: Kalyanam N
Plant Licensing Branch IV
Kalyanam N, NRR/DLPM, 415-1480
Shared Package
ML121800304 List:
References
TAC ME8282
Download: ML121800341 (3)


Text

Response to Item #4 The revised sensitivity analysis CDF increased from 4.27E-05/yr to 6.03E-05/yr LERF increased from 8.34E-07/yr to 1.28E-06/yr Total change:

CDF = 1.76E-5/yr LERF = 4.46E-7/yr Table 1 Comparison of LAR Table W-2 Results with Sensitivity Analysis Results Base Analysis Results (/yr)

(LAR Table W-2)

Sensitivity Results (/yr)

Difference in Results (/yr)

Area Area Description Fire Area CDF Fire Area LERF Fire Area CDF Fire Area LERF CDF LERF B-3 Fire Zones 2091-BB, 2112-BB and 2183-J (electrical penetration rooms) 4.13E-07 1.32E-08 6.68E-07 2.14E-08 2.55E-07 8.20E-09 B-4 Fire Zone 2154-E (CEDM equipment room) 3.26E-06 3.61E-08 5.63E-06 6.22E-08 2.37E-06 2.61E-08 HH Fire Zones 2063-DD, 2072-R, 2073-DD, 2096-M, 2106-R, and 2107-N (sample room, VCT room, 2B-62 room, 2B-63 room, degasifier vacuum pump room, and corridor) 2.82E-06 3.70E-08 3.11E-06 4.66E-08 2.90E-07 9.60E-09 II Fire Zone 2101-AA (north switchgear 2A-3 room) 2.90E-06 9.31E-08 4.10E-06 1.32E-07 1.20E-06 3.89E-08 JJ Fire Zone 2109-U (corridor) 2.70E-06 7.97E-08 1.06E-05 3.11E-07 7.90E-06 2.31E-07 MM Fire Zones 2099-W and 2103-V (west DC equipment room and west battery room) 3.28E-06 7.85E-08 7.36E-06 1.76E-07 4.08E-06 9.75E-08 SS Fire Zones 2097-X, 2100-Z and 2102-Y (east DC equipment room, south switchgear room and east battery room) 2.81E-06 7.43E-08 4.36E-06 1.10E-07 1.55E-06 3.57E-08

The scenarios that require further evaluation to determine whether they screen in the HGL/MCA screening or if they have additional impact upon the CDF/LERF calculations are listed in Table 2.

Table 2 Scenarios that Require Further Evaluation in Sensitivity Analysis Zone Scenario Description Area 2007-LL Base scenario AA 2014-LL Base scenario B-6 2026-Y Base scenario B-1 2033-K Base scenario NN-North 2073-DD-D 2C-115 HH 2097-X Base scenario - Severe Fire SS 2099-W Base scenario - Severe Fire MM 2108-S Base scenario TT 2109-U-D 2Y-1 JJ 2109-U-E 2Y-2 JJ 2111-T-C 2C-410 EE-U 2136-I-B 2C-330 G

2136-I-F 2B-64 G

2137-I-B 2B-61 G

2137-I-C 2C-333 G

2137-I-D 2C-181 G

2150-C Base scenario - Severe Fire G

2151-A Base scenario B-2 2153-A Base scenario B-2 2154-E-B 2C-71, 2C-70; 2C-73, 2C-72 B-4 2154-E-C 2C-80, 2C-409 B-4 2172-ZZ Base scenario B-2 2177-YY Base scenario B-2 2183-J-B 2C-384 B-3 2183-J-C 2C-183 B-3 2200-MM-AH 2C-27A, 2C-27B B-2 2200-MM-AI 2C-301 B-2 2200-MM-BA 2B-25 B-2

Table 2 Scenarios that Require Further Evaluation in Sensitivity Analysis Zone Scenario Description Area 2200-MM-BP Service Air Compressor 2C-3 B-2 2200-MM-C 2A-1 B-2 2200-MM-D 2A-2 B-2 2200-MM-F 2B-22 B-2 2200-MM-G 2B-32 B-2 2200-MM-H 2B-42 B-2 2200-MM-K 2H-1, 2H-2 B-2 2200-MM-L 2P-2A, 2P-2B, 2P-2C, 2P-2D B-2 2200-MM-Q 2B-26 B-2 2200-MM-R 2B-35 B-2 2200-MM-S 2X-23, 2B-3, 2X-24, 2B-4 B-2 2200-MM-T 2B-11 B-2 2200-MM-U 2B-12 B-2 2200-MM-V 2B-21 B-2 2201-B Base scenario B-2 2223-KK Base scenario B-2 2225-WW Base scenario B-2 2231-TT Base scenario B-2 2242-OO Base scenario B-2 2243-NN Base scenario B-2