ML12089A517
| ML12089A517 | |
| Person / Time | |
|---|---|
| Site: | Indian Point |
| Issue date: | 05/24/2011 |
| From: | Vogle R Entergy Corp |
| To: | Atomic Safety and Licensing Board Panel |
| SECY RAS | |
| Shared Package | |
| ML12089A514 | List: |
| References | |
| RAS 22118, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01, nxp IP-EP-410, Rev 7 | |
| Download: ML12089A517 (11) | |
Text
ENT000278 Submitted: March 29, 2012 Enlergy IPEC NON-QUALITY RELATED IP-EP-410 Revision 7 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page 1
of 11 Protective Action Recommendations Prepared by:
Print Name Print Name Approval:
Brian Sullivan Dale Effective Date: June 30, 2011 IP-EP-410 (PAR) R7.doc Enlergy IPEC NON-QUALITY RELATED IP-EP-410 Revision 7 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page 1
of 11 Protective Action Recommendations Prepared by:
Print Name Print Name Approval:
Brian Sullivan Dale Effective Date: June 30, 2011 IP-EP-410 (PAR) R7.doc
Enlergy",
IPEC NON-QUALITY RELATED IP-EP-410 Revision 7 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page
~
of 11 Table of Contents 1.0 PURPOSE..................................................................................................................................... 3 2.0 REFERENCES............................................................................................................................. 3 3.0 DEFINITIONS............................................................................................................................... 3 4.0 RESPONSiBILITIES.................................................................................................................... 3 5.0 DETAILS........................................................................................................................................ 3 5. 1 NUE. ALERT. SITE AREA EMERGENCy.............................................................................. 3 5.2 GENERAL EMERGENCY...................................................................................................... 3 6.0 INTERFACES............................................................................................................................... 4 7.0 RECORDS..................................................................................................................................... 4 8.0 REQUIREMENTS AND COMMITMENT CROSS-REFERENCE.......................................... 4 9.0 ATIACHMENTS........................................................................................................................... 4 9.1 FLOWCHART FOR GENERAL EMERGENCY PROTECTIVE ACTION DECISIONS..................... 5 9.2 STABILITY CATEGORY - DOWNWIND KEYHOLE SECTOR C ORRELATION TABLE................. 6 9.3 EPA PROTECTIVE ACTION GUiDELINES............................................................................... 7 9.4 OVERLAY SELECTION FLOW CHART.................................................................................... 8 9.5 BASIS FOR SECTOR SELECTION IN PAR DETERMINATION.......................................... 9 9.6 OVERLAY STABILITY CATEGORY-D OWNWIND KEYHOLE SECTOR CORRELATION TABLE.. 1 0 9.7 PROTECTIVE ACTION RECOMMENDATION DETERMINATION.............................................. 1 1
IPEC NON~aUALITV RELATED IP~EP-410 Revision 7
-=-BnLergy.
EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page
~
of 11 PROTECTIVE ACTION RECOMMENDATIONS 1.0 PURPOSE To prescribe the responsibilities and methods for determining recommended protective actions for New York State and County authorities.
2.0 REFERENCES
EPA Protective Action Guidelines 3.0 DEFINITIONS Protective Action Recommendations (PARs) - Specific recommendations made by the Emergency Director to the local authorities in accordance with Emergency Plan procedures based on Protection Action Guidelines.
4.0 RESPONSIBILITIES 4.1 The Shift Manager is responsible for evaluating accident conditions, classifying the accident, and recommending protective actions to offsite authorities during the initial phases of the accident. The Emergency Director assumes these responsibilities when he takes control of the emergency response from the Shift Manager. The Radiological Assessment Coordinator will assist the Emergency Director with protective action recommendations.
4.2 The decision to initiate any protective actions is solely the responsibility of the local authorities.
5.0 DETAILS 5.1 NUE. Alert. Site Area Emergency Recommend no protective actions be taken.
5.2 General Emergency 5.2.1 The initial protective action recommendation should be made within 15 minutes of the GENERAL EMERGENCY declaration.
5.2.2 Protective Action Recommendations (PARs) shall be made in accordance with Attachment 9.1. Downwind Sectors are identified on Attachment 9.2.
5.2.3 Downwind sectors in Attachment 9.2 are determined using MIDAS wind fields. If MIDAS is unavailable, the isopleth overlays may be used as backup (Use Attachments 9.4 and 9.6 to support isopleth and sector selection) NOTE: Due to the wind field origin change between MIDAS and the isopleth overlays there is a difference in the down-valley plume shape. When using the overlays as a substitute for MIDAS, down-valley PARs may be different by one sector.
e IPEC NON-QUALITY RELATED IP-EP-410 Revision 7
= Entergy.
EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page 01 11 5.2.4 The initial PAR shall be made in the first GENERAL EMERGENCY notification to the State/Counties. All subsequent, Part I notifications shall include the latest PAR.
5.2.5 Re-evaluate the PARs based on the following: (Attachment 9.7)
Changes in Wind Direction or Speed Dose Assessment - (When release duration is NOT able to be estimated, use four hours as a default value),
Field Data EPA PAGs - Attachment 9.3 Plant Conditions 5.2.6 As protective action recommendations change, ensure appropriate steps are taken to protect the onsite population.
5.2.7 IF dose projections indicate an EPA PAG wilt be exceeded beyond 10 miles THEN send field teams to confirm projections and discuss possible protective actions with offsite officials if projections prove possible.
6.0 INTERFACES 6.1 Evacuation Travel Time Estimates 6.2 IP-EP-310, Dose Assessment 6.3 State of New York KI Policy Paper 6.4 IP-EP-420, Use of Potassium Iodide by Indian Point Personnel during an Emergency 7.0 RECORDS NONE 8.0 REQUIREMENTS AND COMMITMENT CROSS-REFERENCE NONE 9.0 ATTACHMENTS 9.1 Flowchart for General Emergency Protective Action Decisions 9.2 Stability Category - Downwind Keyhole Sector Correlation Table 9.3 EPA Protective Action Guidelines 9.4 Overlay Selection Flow Chart 9.5 Basis for Sector Selection in PAR Determination 9.6 Overlay Stability Category-Downwind Keyhole Sector Correlation Table 9.7 Protective Action Recommendation Determination
e IPEC NoM-OuALITY RELATED IP-EP-410 Revision 7
-=-Entergy.
EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page
§ of 11.1 FLOWCHART FOR GENERAL EMERGENCY PROTECTIVE ACTION DECISIONS Sheet 1 of 1 General Emergency Decfarect
- Recommend EVACUATION and.Impl~ntatlon of the KI Plan fot 2 Mile Radlua and 2-6 Miles Downw"'d Sectors and advise remainder of EPZ population to golndoora and latan to EAS.
(Attachment 9.2)
Continue Asa_ament ba.ed on:
Wind Speedl Direction Dose Ass_sment FleidDaIa EPA PAGa III Plant Conditions (Attachment 9.7)
NO Recommend EVACUATION and Implementation of the KI Plan for 5 Mile Radll.- and 5-10 Miles Downwind Sectors (see notes) and advise remainder of EPZ popuatlon to go Indoors and listen to EAS. (Attac:hment 9.2)
NO Recommend EVACUATION and Implementation of the KI Plan for entire 10 mile radius A radiological release'.
underway:ot.,tldpated (wlthln1S 1'11... ) which Is of ahort duration <<1 hr)
YES Recommend SHELTER and Implenwntatlon of the KI PI.,
for2 Mile Radua and 2--6 mles downwind Sectors and advise remainder of EPZpopulation to go Indoors and listen to EAS.
(Attachment 9.2)
Notes:
(1) Reterto Attachment 9.3 for details on EPA P AGs.
(2) IF an EPA PAG Is exceeded or expected to be exceeded beyond 10 miles THEN.
consider the need for PARs beyond 10 miles and discuss possible actons with State.
(3) IF recommended Sectors change THEN add new Sectors to new PAR. DO NOT subtract any Sector in which actions have previously been recommended.
(4) After Initial PAR, evaluate new PARS using Attachment 9.7
~ Entergyll!i IPEC NON-QUALITY RELATED IP-EP-410 Revision 7 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page
§ -.2 Stability Category - Downwind Keyhole Sector Correlation Table Sheet 1 of 1 TABLE I - MIDAS Up-Valley Plumes Up-Valley Plumes (wind speeQ ~ 4 m/sec and wind direction from 102°.209°)
Pasquil Stability Categories Sectors affected A, S 16, 1,2,. 3,4 C, D,E, F,G 16, 1, 2, 3 TABLE II - MIDAS Down-Valley Plumes Down-Valley Plumes (wind speed ~ 4 m/sec and wind direction from 349°-101°)
Pasquill Stability Categories Sectors affected A.S 7, 8,9, 10, 11 C, D, E,F,G 7, 8,9, 10 TABLE 111-MIDAS Cross-Valley Plumes Cross-Valley (wind speed> 4 m/sec OR wind direction from 210°-348°)
of 11 Wind Direct Center Pasquil Stability Categories A & S Pasquil Stability Categories CoG From (deg)
Sector No Sectors affected Sectors affected 169 - 190 1 N 15, 16,1,2, 3 16,1,2 191 - 213 2 NNE 16, 1, 2, 3, 4 1,2,3 214 - 235 3NE 1, 2,3, 4,5 2, 3, 4 236 - 258 4 ENE 2,3, 4,5,6 3,4,5 259 - 280 5E 3,4, 5,6,7 4,5,6 281 - 303 6 ESE 4,5, 6,7,8 5,6,7 304 - 325 7 SE 5.6, 7. 8.9 6, 7, 8 326 - 348 8 SSE 6, 7. 8, 9. 10
- 7. 8. 9 349 - 010 9S 7, 8, 9. 10, 11 8, 9, 10 011 - 033 10 SSW 8, 9, 10, 11. 12 9, 10. 11 034 - 055 11 SW
- 9. 10.11, 12, 13 10, 11. 12 056 - 078 12 WSW 10, 11, 12,13,14 11, 12, 13 079 - 100 13W 11,12,1 3. 14, 15 12, 13. 14 101 - 123 14 WNW 12, 13. 14. 15, 16 13, 14. 15 124 - 145 15 NW 13, 14,1 5, 16. 1 14, 15. 16 146 - 168 16 NNW
- 14. 15, 16, 1, 2 15, 16, 1
f/)Entergy/l}
IPEC NON-QUALITY RELATED IP-EP-410 Revision 7 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page
- 1.
of 11
--.3 EPA PROTECTIVE ACTION GUIDELINES Sheet 1 of 1 Recommended protective actions to reduce whole body and thyroid dose from exposure to a gaseous plume.
PROJECTED DOSE (REM)
TO THE POPULATION Whole Body (TEDE)
Thyroid (CDE)
Whole Body (TED E)
Thyroid (CDE)
< 1
<5
~5 RECOMMENDED ACTIONS (a)
No planned actions. (b)
State may issue an advisory to seek shelter and await further instructions.
Monitor environmental radiation levels Evacuate unless constraints make it impractical; then shelter. Monitor environmental radiation levels.
Control access.
COMMENTS Previously recommended protective actions may be reconsidered or terminated.
If constraints exist, special consideration should be given for evacuation of children and pregnant women.
GUIDANCE ON DOSE LIMITS FOR WORKERS PERFORMING EMERGENCY SERVICES (REM)
Whole Body (TEDE):
10 25
> 25 Protecting valuable property Lifesaving or protection of large populations Lifesaving or protection of large population Lower dose not practicable.
Lower dose not practicable.
Only on a voluntary basis to persons fully aware of the risks involved.
TEDE-Total Effective Dose Equivalent: Sum of external effective dose equivalent and committed effective dose equivalent to nonpregnant adults from exposure and intake during an emergency situation. Workers performing services during emergencies should limit dose to the lens of the eye to three times the listed value and doses to any organ (including skin and body extremities) to ten times the listed value.
CDE-Committed dose equivalent (to the Thyroid).
(a)
These actions are recommended for planning purposes. Protective action decisions at the time of the incident must take existing conditions into consideration.
(b)
At the time of the incident, officials may implement low-impact protective actions in keeping with the principle of maintaining radiation exposures as low as reasonably achievable (ALARA)
e IPEC NON-QUAUTY RELATED IP-EP-410 Revision 7 Entergy.
EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page
§ of 11.4 OVERLAY SELECTION FLOW CHART(lSOPLETHS for HAND CALC)
Sheet 1 of 1 I
OBTAIN METEOROLOGICAL DATA I
I I
RECORD WIND DIRECTION I
J I
RECORD WIND SPEED I
I I
RECORD PASQUILL STABILITY CLASS I
I I
WIND SPEED So 4 m/s WIND SPEED> 4 m/s I
I WIND DIRECTION WIND DIRECTION WIND DIRECTION 340°.
101 ° 102°* 209° 210 0.
339° I
I USE DOWN VALLEY USE UP VALLEY OVERLAY USE CROSS VALLEY OVERLAY GROUND OR GROUND OR ELEV.
OVERLAY GROUND OR ELEV.
(Yellow)
ELEV.
(Blue)
(Red)
I I
PLACE OVERLAY OVER ALIGN OVERLAY ALONG PLANT ORIENTATION POINT (1)
WIND DIRECTION 1 Plant Orientation Point
- a.
Using down valley overlay (Blue) align horizontal axis on 90 0
- 270 0 line with plume extending south.
r--
- b. Using up valley overlay (Yellow) align horizontal axis on 90° - 270 0 line with plume extending north.
fIJ Entergy8 IPEC NON..QUALITY RELATED IP-EP-410 Revision 7 EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page
~
of 11 Attachment 9.5 Basis for Sector Selection in PAR Determination Sheet 1 of 1 The Sectors provided in the Protective Action Recommendations (PARs) in this procedure are based on the following determinations:
When the conditions support Up-Valley Plumes (wind speed. ~ 4 m/sec and wind direction from 102°-209°) and either Pasquil Category A or B is in effect, the MIDAS display and appropriate overlay were viewed on the map and the affected Sectors were determined (Affected Sectors are any Sector that the Isopleth Lines touch beyond 2 miles). This was determined to be Sectors 16, 1,2, 3 and 4.
When the conditions support Up-Valley Plumes (wind speed. ~ 4 m/sec and wind direction from 102°-209°) and either Pasquil Category C, 0, E, F or G is in effect, the MIDAS display and appropriate overlay were placed on the map and the affected Sectors were determined.
(Affected Sectors are any Sector that the Isopleth Lines touch beyond 2 miles). This was determined to be Sectors 16, 1, 2 and 3.
When the conditions support Down-Valley Plumes (wind speed.~ 4 m/sec and wind direction from (349-101 for MIDAS and 340°-101° for overlay) and either Pasquil Category A or B is in effect, the appropriate overlay was placed on the map and the affected Sectors were determined. (Affected Sectors are any Sector that the Isopleth Lines touch beyond 2 miles).
This was determined to be Sectors 7, 8, 9, 10 and 11.
When the conditions support Down-Valley Plumes (wind speed. ~ 4 m/sec and wind direction from 349-101 for MIDAS and 340°-101° for overlay) and either Pasquil Category C, 0, E, For G is in effect, the appropriate MIDAS display or overlay was placed on the map and the affected Sectors were determined. (Affected Sectors are any Sector that the Isopleth Lines touch beyond 2 miles). This was determined to be Sectors 7,8,9 and 10.
When the conditions support Cross-Valley Plumes (wind speed. > 4 m/sec OR wind direction from 210°-348 for MIDAS and 210-339° for overlay) and either Pasquil Category A or B is in effect, the appropriate MIDAS display or overlay was placed on the map and the affected Sectors were determined. (Affected Sectors are any Sector that the Isopleth Lines touch beyond 2 miles).
This was determined to be the Sector in which the Plume Centerline lays and 2 Sectors on either side of the centerline Sector.
When the conditions support Cross-Valley Plumes (wind speed. > 4 m/sec OR wind direction from 210°-348 for MIDAS and 210 - 339 for overlay) and either Pasquil Category C, 0, E, F and G is in effect, the appropriate overlay was placed on the map and the affected Sectors were determined. (Affected Sectors are any Sector that the Isopleth Lines touch beyond 2 miles). This was determined to be the Sector in which the Plume Centerline lays and 1 Sector on either side of the centerline Sector.
IJ/I) Entergy.
IPEC NON-QuALITY RELATED EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE.6 For Use as Backup ONLY IP-EP-410 Revision 7 Page 10 of 11 Overlay Stability Category - Downwind Keyhole Sector Correlation Table Sheet 1 of 1 T ABLE I OVERLAY U V II PI
,p-1 a ey umes Up-Valley Plumes (wind speed. S 4 m/sec and wind direction from 102°-209")
Pasquil Stability Categories Sectors affected A, B 16,1,2,3,4 C, D,E,F,G 16,1,2, 3 TABLE II OVERLAY 0 own-V II PI umes a ey Down-Valley Plumes (wind speed s4 m/sec and wind direction from 340°-101°)
Pasquilf Stability Categories Sectors affected A,B 7,8,9.10,11 C.D,E,F,G 7, 8,9, 10 TABLE 111-o VERLAY c P
ross-Valley *. Iumes Cross-Valley (wind speed > 4 m/sec OR wind direction from 210°-339")
Wind Direct Center Pasquil Stability Categories A & B Pasquil Stability Categories CoG From (deg)
Sector No Sectors affected Sectors affected 169 - 190 1 N 15,16,1,2,3 16,1,2 191 *213 2 NNE 16, 1, 2,3, 4 1, 2,3 214*235 3NE 1,2,3,4,5 2,3,4 236*258 4 ENE 2, 3,4,5,6 3,4,5 259*280 5E 3, 4,5, 6,7 4,5,6 281 - 303 6 ESE 4, 5,6,7, 8 5,6,7 304 - 325 7SE 5,6,7, 8,9 6, 7, 8 326
- 348 8 SSE 6, 7, 8, 9,10 7, 8, 9 349* 010 9S 7, 8,9,10, 11 8,9, 10 011 *033 10 SSW 8, 9, 10, 11, 12 9, 10. 11 034 - 055 11 SW 9,10,11,12,13 10,11,12 056 - 078 12WSW 10,11, 12, 13,14 11, 12, 13 079 -100 13W 11, 12,13, 14,15 12, 13, 14 101 - 123 14WNW 12,13, 14, 15, 16 13, 14, 15 124 - 145 15NW
- 13. 14, 15, 16, 1 14,15, 16 146 - 168 16NNW 14, 15, 16,1, 2 15,16,1
IPEC NON-QUAUTY RELATED IP-EP-410 Revision 7
-= Entergy.
EMERGENCY PLAN PROCEDURE IMPLEMENTING PROCEDURES REFERENCE USE Page 11 of 11.7 Protective Action Recommendation Determination Assessment Guidance Page 1 of 1 General Emergency Declared (Initial Declaration)
Recommend the predefined plant condition PAR in accordance with Meteoroloaicalln1ormatlon General Emergency Continues and new PAR is being considered based on a wind shift or for any other reason NOTE 1 NOTE 2 Does a potential loss of the containment fission product barrier exist and containment source term indicatesPAGs could be exceeded in the new area if a release were to start?
c$
Does the radiological assessment show EPA PAGs will be rl YES /--
exceeded in the new area based on an actual release that is occurrina?
c$
Are plant conditions understood that could impact or cause Recommend a PAR additional core damage (e.g., stableandlor magnitude of source for the new sector(s) term, core recovered, coolable geometry?
or area(s) based on I
dose assessment I YES I results only y
Is the radiological release pathway understood (filtered, non-filtered, monitored, unmonitored with little or no potential for release rate to increase, little or no potential for RCS leak to increase)?
I I YES I I YES OR NlA If available, does off-site radiological data support the protective action recommendation methodoloGv based on dose assessment?
r H
YES I
~
~
No NOTE 1: For PARs issued from the Control Room: Subsequent PARs are based on an extension of the initial default PAR to the new sectors and modified for other areas farther downwind based on dose assessment results as necessary.
NOTE 2: Do not use this flow chart when there is NO LOSS or POTENTIAL LOSS of the containment barrier.
Base any subsequent PARs on dose assessment using the new conditions for the area of interest.