ML12020A097
ML12020A097 | |
Person / Time | |
---|---|
Site: | Plum Brook |
Issue date: | 01/18/2012 |
From: | Mann B US National Aeronautics & Space Admin (NASA) |
To: | NRC/FSME |
References | |
Download: ML12020A097 (65) | |
Text
Plum Brook Reactor Facility Final Status Survey Report Primary Pump House (Building 1134)
Revision 0 Appendix B Survey Unit Maps and Tables Showing Measurement Locations and Results
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 2 of 45 Index of Primary Pump House Survey Unit Maps and Tables of Coordinates Survey Description Page Number Unit Number of Pages PH-I-1 Room I- Floor, Ceiling, Platform, Hatchways 4 1 PH 2 Room 1- Walls 5 1 PH 3 Room 2- Floor, Ceiling, Platform, Hatchways 6 I PH 4 Room 2- Walls 7 1 PH 5 Room 3- Floor, Ceiling, Platform, Hatchways 8 1 PH 6 Room 3- Walls 9 1 PH 7 Room 4- Floor Section 1 10 1 PH 8 Room 4- Floor Section 2 11 1 PH 9 Room 4- West & North Walls 12 1 PH 10 Room 4- East & South Walls 13 1 PH 11 Room 4- West Ceiling & Hatchway 14 1 PH 12 Room 4- East Ceiling & Hatchway 15 1 PH 13 Room 5 - Floor, Ceiling, & Hatchway 16 1 PH 14 Room 5 - Walls 17 1 PH 15 Room 6 - Floor, Ceiling, & Hatchway 18 1 PH 16 Room 6 - Walls 19 1 PH 17 Room 7 & 8 - Floor Section 1 20 1 PH 18 Room 7 & 8 - Floor Section 2 21 1 PH 19 Room 7 & 8 - Floor Section 3 22 1 PH 20 Room 8 Sump 23 1 PH 21 Room 7 & 8 - Wall Section 1 & West Stairs 24 1 PH 22 Room 7 & 8 - Wall Section 2 25 1 PH 23 Room 7 & 8 - Wall Section 3 & East Stairs 26 1 PH 24 Room 7 & 8 - Wall Section 4 27 1 PH 25 Room 7 & 8 - Wall Section 5 28 1 PH 26 Room 7 & 8 - Wall Section 6 29 1 PH 27 Room 7 & 8 - Platforms 30 1 PH 28 Room 7 & 8 - Ceiling Section 1 31 1 PH 29 Room 7 & 8 - Ceiling Section 2 32 1 PH-1-30 Room 3 Soil 33 1 PH-2-1 Roof Section #1 34 1 PH-2-2 Roof Section #2 35 1 PH-2-3 Roof Section #3 36 1 PH-2-4 Roof Section #4 37 1 PH-2-5 Roof Section #5 38 1 PH-2-6 Roof Section #6 39 1 PH-2-7 South Wall - Lower 40 1 PH-2-8 South Wall - Upper 41 1 PH-2-9 East Wall - Lower 42 1 PH-2-10 East Wall - Upper 43 1 PH-2-11 North Wall - Lower 44 1 PH-2-12 North Wall - Upper 45 1
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 3 of 45 Appendix B Note:
- 1. Occasionally negative values of individual measurements appear in the tables in this appendix. In accordance with PBRF FSS/Characterization procedures, each measurement result in dpm/100-cm 2 is obtained by taking a shielded measurement and an unshielded measurement at each location established in the survey design. The shield is of sufficient thickness to completely attenuate (absorb) the most energetic beta from PBRF residual surface contamination (Sr/Y-90). The net activity is then determined as:
Net activity in dpm/I00-cm 2 = (Unshielded cpm - Shielded cpm): Where:
E, (A/100)
Unshielded cpm is the detector response including contributions from radiation entering the detector sensitive face (open area) and from ambient radiation (mostly gammas) entering the detector from all directions.
Shielded cpm is the detector response with the shield in place between the detector sensitive face and the surface being investigated. The shield eliminates beta particles from the surface under investigation and the detector response is due only to ambient radiation that enters the detector (from all directions).
(Unshielded cpm - Shielded cpm) is the net cpm due to activity, mostly beta particles entering the detector from the surface under investigation. Note that the net cpm includes contributions from residual contamination that may be present and from naturally occurring beta emitters in the material. This natural background component is considered to be small and is neglected, i. e., this background contribution is not subtracted in determining net cpm.
Detector efficiency, Et, dpm/cpm for the detector, is the product of the detector efficiency and the surface efficiency. A typical value of E, for the Ludlum 44-116 detector, the detector of choice for FSS systematic measurements in structures, is approximately 15% (0.15).
A/100 is the factor to convert dpm per detector area to dpm/1 00-cm 2, where A is the detector open area in cm 2. The open area of the Ludlum 44-116 is 100 cm2, so the (A/100) factor is unity in this case.
Negative values of net activity occur when the measured shielded cpm is greater than the measured unshielded cpm at a location. This most often occurs in survey units where residual contamination levels are low, near background, and the ambient background is also low. Thus, the random variability of low level count rates will result in occasional measurement pairs where the recorded shielded count rate exceeds the unshielded count rate.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 4 of 45 Survey Unit PH-1-1 1 - Floor, Ceiling, Platform and Hatchways SM-ig If~
I I 1 I =
-Li LI II I 13 a
PH-1-1 AREA: PPH Room #1 - Floor, Ceiling, Platform and Hatchways Measurement Locations and results Location /
X Co-ord (im) Y Co-ord (m) dpml1 00-cm 2 Type Notes 2.2 2.2 SM-1 862 Systematic N/A 0.1 0.3 SM-2 382 Systematic N/A 2.7 0.3 SM-3 763 Systematic N/A 0.2 2.5 SM-4 493 Systematic N/A 1.5 1.0 SM-5 789 Systematic N/A 0.7 Edge SM-6 1487 Systematic N/A 0.2 3.3 SM-7 882 Systematic N/A 2.8 3.3 SM-8 1250 Systematic N/A 0.8 Edge SM-9 1099 Systematic N/A 0.2 Edge SM-10 711 Systematic N/A 0.5 Edge SM-11 730 Systematic N/A Sample measurements are taken from the southwest or lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 5 of 45 Survey Unit PH-1-2 Room 1 - Walls
- gigSM-I0
- ZZZZZZK SM[I PH-1-2 AREA: PPH Room #1 - Walls Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpml/00-cm 2 Type Notes 1.1 0.8 SM-1 1342 Systematic N/A 0.4 0.8 SM-2 1112 Systematic N/A 3.4 0.8 SM-3 803 Systematic N/A 2.0 0.8 SM-4 658 Systematic N/A 1.3 0.8 SM-5 711 Systematic N/A Edge 0.8 SM-6 809 Systematic N/A 2.6 3.4 SM-7 1007 Systematic N/A 1.9 3.4 SM-8 849 Systematic N/A 0.5 3.4 SM-9 638 Systematic N/A 3.5 3.4 SM-10 691 Systematic N/A 2.8 3.4 SM-1l 500 Systematic N/A Sample measurements are taken from the lower left hand corner of the wall surface on which they lie.
Plum 'Erook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 6 of 45 Room 2 - Fhi or, ýC m and Hatch 1~i~
C
- 1ii~ i~i:i PH-1-3 AREA: PPH Room #2 - Floor, Ceiling, Platform and Hatch Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpn/1 00-cm 2 Type Notes 0.7 0.8 SM-1 762 Systematic N/A 3.3 0.8 SM-2 1224 Systematic N/A 2.0 3.1 SM-3 1077 Systematic N/A 2.4 2.0 SM-4 958 Systematic N/A 0.3 1.1 SM-5 1378 Systematic N/A 1.8 0.7 SM-6 1895 Systematic N/A 0.1 2.9 SM-7 441 Systematic N/A 0.5 2.9 SM-8 1552 Systematic N/A Edge Edge SM-9 1322 Systematic N/A 0.1 Edge SM-10 1098 Systematic N/A 0.8 Edge SM-1 1 769 Systematic N/A Sample measurements are taken from the southwest or lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 7 of 45 Survey Unit PH-1-4 Room 2 - Walls 0
PH-1-4 AREA: PPH Room #2- Walls Measurement Locations and results Location /
X Co-ord (in) Y Co-ord (m) DPM/IOOcm2 Type Notes 0.0 0.4 SM-1 1118 Systematic N/A 3.0 0.4 SM-2 1217 Systematic N/A 2.3 0.4 SM-3 1020 Systematic N/A 0.9 0.4 SM-4 941 Systematic N/A 0.3 0.4 SM-5 842 Systematic N/A 3.2 0.4 SM-6 1039 Systematic N/A 1.5 3.0 SM-7 1046 Systematic N/A 0.8 3.0 SM-8 757 Systematic N/A 3.8 3.0 SM-9 829 Systematic N/A 2.4 3.0 SM-1 0 796 Systematic N/A 1.8 3.0 SM-11 796 Systematic N/A Sample measurements are taken trom the lower left corner of the surtace on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 8 of 45 Survey Unit PH-1-5 Room 3 - Floor, Ceiling, Platform and Hatch 0
0 SMM 0
0 F--1 E]
2 E]i L PH-1-5 AREA: PPH Room #3 - Floor, Ceiling, Platform and Hatch Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpn/I100-cim 2 Type Notes Edge 1.4 SM-1 881 Systematic N/A Edge 1.1 SM-2 615 Systematic N/A 1.3 0.2 SM-3 1063 Systematic N/A 3.7 0.2 SM-4 888 Systematic N/A 1.8 Edge SM-5 573 Systematic N/A 0.5 Edge SM-6 1357 Systematic N/A 1.8 1.8 SM-7 2364 Systematic N/A 1.8 1.8 SM-8 3622 Systematic N/A Edge 1.2 SM-9 825 Systematic N/A 2.5 1.2 SM-10 1147 Systematic N/A 1.3 3.3 SM-11 1042 Systematic N/A Sampie measurements are taken Trom me southwest or lower iert corner or me surrace on wnicn they rest.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 9 of 45 Survey Unit PH-1-6 Room 3 - Walls FSjj: SM 0
00 PH-1-6 AREA: PPH Room #3 - Walls Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpmll 00-cm 2 Type Notes 0.1 1.2 SM-1 1250 Systematic N/A 3.2 1.2 SM-2 1467 Systematic N/A 2.5 1.2 SM-3 1796 Systematic N/A 1.2 1.2 SM-4 1980 Systematic N/A 0.5 1.2 SM-5 4849 Systematic N/A 3.6 1.2 SM-6 1270 Systematic N/A 1.6 3.8 SM-7 2592 Systematic N/A 1.0 3.8 SM-8 1592 Systematic N/A 4.0 3.8 SM-9 1118 Systematic N/A 2.7 3.8 SM-10 1730 Systematic N/A 2.1 3.8 SM-11 1526 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 10 of 45 Survey Unit PH-1-7 Room 4 - Floor Section #1 0 0 0
0a 0 00e 0o 0
o
--- 16 --
I II II PH-1-7 AREA: PPH Room #4 - Floor Section #1 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpmll 00-cm 2 Type Notes 4.1 0.6 SM-1 796 Systematic N/A 6.8 0.6 SM-2 1000 Systematic N/A 9.6 0.6 SM-3 1118 Systematic N/A 2.7 3.0 SM-4 888 Systematic N/A 5.5 3.0 SM-5 539 Systematic N/A 8.2 3.0 SM-6 822 Systematic N/A 0.6 1.7 SM-7 368 Systematic N/A 0.5 1.7 SM-8 724 Systematic N/A 1.1 1.7 SM-9 513 Systematic N/A 1.0 1.7 SM-10 711 Systematic N/A 0.5 0.7 SM-11 -204 Systematic N/A Sample measurements are taken from the southwest or lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 11 of 45 Survey Unit PH-1-8 Room 4 - Floor Section #2 LIII -77 W
0 0
CýO 0 a (Z)
LII4 0 EZZI rzz~
OSM0 EZI0 PH-1-8 AREA: PPH Room #4 - Floor Section #2 Measurement Locations and results Location I X Co-ord m) YCo-ord (m) dpm/1OO-cm 2 Type Notes 1.5 0.1 SM-1 638 Systematic N/A 4.2 0.1 SM-2 717 Systematic N/A 7.0 0.1 SM-3 862 Systematic N/A 9.7 0.1 SM-4 697 Systematic N/A 0.1 2.5 SM-5 678 Systematic N/A 2.8 2.5 SM-6 1000 Systematic N/A 5.6 2.5 SM-7 1013 Systematic N/A 8.4 2.5 SM-8 592 Systematic N/A 1.5 4.9 SM-9 882 Systematic N/A 4.2 4.9 SM-10 1013 Systematic N/A 7.0 4.9 SM-11 664 Systematic N/A 9.7 4.9 SM-12 1072 Systematic N/A Sample measurements are taken from the southwest corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 12 of 45 Survey Unit PH-1-9 Room 4 - West and North Walls U E 0
D [11111 PH-1-9 AREA: PPH Room #4 - West and North Walls Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 1.3 0.7 SM-1 1797 Systematic N/A 4.6 0.7 SM-2 1147 Systematic N/A 7.8 0.7 SM-3 699 Systematic N/A 4.2 0.7 SM-4 790 Systematic N/A 7.4 0.7 SM-5 776 Systematic N/A 3.0 3.5 SM-6 1175 Systematic N/A 6.2 3.5 SM-7 755 Systematic N/A 9.4 3.5 SM-8 657 Systematic N/A 2.6 3.5 SM-9 629 Systematic N/A 5.8 3.5 SM-10 636 Systematic N/A 9.0 3.5 SM-11 1021 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 13 of 45 Survey Unit PH-I-10 Room 4 - East and South Walls -
D D--
PH-I-10 AREA: PPH Room #4 - East and South Walls Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (mi) dpm/1 00-cm 2 Type Notes 0.9 1.6 SM-1 608 Systematic N/A 4.0 1.6 SM-2 601 Systematic N/A 7.1 1.6 SM-3 678 Systematic N/A 0.2 1.6 SM-4 972 Systematic N/A 9.6 1.6 SM-5 566 Systematic N/A 2.4 4.3 SM-6 741 Systematic N/A 5.6 4.3 SM-7 797 Systematic N/A 8.7 4.3 SM-8 608 Systematic N/A 1.8 4.3 SM-9 832 Systematic N/A 5.0 4.3 SM-10 832 Systematic N/A 8.1 4.3 SM-11 727 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 14 of 45 Survey Unit PH-I-I 1 Room 4 - West Ceiling and Hatchway D *ffu D
PH-1-11 AREA: PPH Room #4 - West Ceiling and Hatchway Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpml/00-cm 2 Type Notes 0.3 0.2 SM-1 928 Systematic N/A 1.1 0.2 SM-2 507 Systematic N/A 0.7 0.2 SM-3 638 Systematic N/A 1.1 1.9 SM-4 803 Systematic N/A 3.5 1.9 SM-5 566 Systematic N/A 2.3 4.0 SM-6 809 Systematic N/A 4.8 4.0 SM-7 362 Systematic N/A 1.1 6.1 SM-8 658 Systematic N/A 3.5 6.1 SM-9 651 Systematic N/A 2.3 8.2 SM-10 776 Systematic N/A 4.8 8.2 SM-11 862 Systematic N/A Sample measurements are taken from the southwest or lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 15 of 45 Survey Unit PH-1 -12 Room 4 - East Ceiling and Hatchway LzIzJI
- NgA 1Is U
- kgg U
- M *K=
PH-1-12 AREA: PPH Room #4 - East Ceiling and Hatchway Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.4 Edge SM-1 1469 Systematic N/A 0.9 1.6 SM-2 853 Systematic N/A 3.2 1.6 SM-3 734 Systematic N/A 2.0 3.6 SM-4 734 Systematic N/A 4.4 3.6 SM-5 594 Systematic N/A 0.9 5.7 SM-6 692 Systematic N/A 3.2 5.7 SM-7 804 Systematic N/A 2.0 7.7 SM-8 392 Systematic N/A 4.4 7.7 SM-9 965 Systematic N/A 0.9 9.7 SM-10 713 Systematic N/A 3.2 9.7 SM-11 371 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they rest (SM-1) or from the southwest corner of the survey unit (SM-2 to SM-1 1).
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 16 of 45 Survey Unit PH-1 -13 Room 5 - Floor, Ceiling, Platform and Hatch D
0 CSO SM-1 1~iJ PH-1-13 AREA: PPH Room #6 - Floor, Ceiling, Platform and Hatch Measurement Locations and results Location /
X Co-ord (m) Y Co-ord im) dpm/100-cm2 Type Notes 0.2 0.2 SM-1 706 Systematic N/A 2.2 0.2 SM-2 629 Systematic N/A 4.3 0.2 SM-3 937 Systematic N/A 1.2 1.9 SM-4 608 Systematic N/A 3.3 1.9 SM-5 741 Systematic N/A 1.5 1.6 SM-6 476 Systematic N/A 3.6 1.6 SM-7 825 Systematic N/A 0.5 3.4 SM-8 818 Systematic N/A 2.6 3.4 SM-9 713 Systematic N/A Edge 0.9 SM-1 0 594 Systematic N/A 0.1 1.6 SM-11 42 Systematic N/A Sample measurements are taken from the southwest corner of the surface on which they lie, except for SM-1 1, which is measured from the lower left corner of the sump surface as shown on the map, with its left edge being the north line of the sump.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 17 of 45 Survey Unit PH-1-14 Room 5 - Walls PH-1-14 AREA: PPH Room #6 -Walls Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/100-cm 2 Type Notes 1.7 0.4 SM-1 1070 Systematic N/A 1.4 0.4 SM-2 816 Systematic N/A 1.4 0.4 SM-3 711 Systematic N/A 2.2 0.4 SM-4 895 Systematic N/A 1.3 0.4 SM-5 1190 Systematic N/A 4.1 0.4 SM-6 704 Systematic N/A 0.3 2.9 SM-7 664 Systematic N/A 0.1 2.9 SM-8 796 Systematic N/A 0.7 2.9 SM-9 658 Systematic N/A 3.5 2.9 SM-10 1040 Systematic N/A 2.7 2.9 SM-1l 645 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 18 of 45 Survey Unit PH-1 -15 Room 6 - Floor, Ceiling, Platform and Hatch 2o I
DI I I 1ii~ *Eii7~
I DI I I I Lii D 0 lkii PH-1-15 AREA: PPH Room #6 - Floor, Ceiling, Platform and Hatch Measurement Locations and results Location I X Co-ord (m) Y Co-ord (m) dpmnl100-cim 2 Type Notes 1.4 0.3 SM-1 706 Systematic N/A 3.7 0.3 SM-2 825 Systematic N/A 0.2 2.3 SM-3 965 Systematic N/A 2.5 2.3 SM-4 958 Systematic N/A 3.7 4.3 SM-5 797 Systematic N/A 1.2 1.4 SM-6 1570 Systematic N/A 3.6 1.4 SM-7 958 Systematic N/A 0.1 3.5 SM-8 385 Systematic N/A 2.4 3.5 SM-9 965 Systematic N/A 1.2 5.5 SM-10 1170 Systematic N/A 3.6 5.5 SM-11 937 Systematic N/A Sample measurements are taken from the southwest corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 19 of 45 Survey Unit PH-1-16 Room 6 - Walls 0
0 0
o o 0
0 PH-1-16 AREA: PPH Room #6- Walls Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 2.5 0.2 SM-1 1520 Systematic N/A 0.8 0.2 SM-2 1980 Systematic N/A 0.2 0.2 SM-3 1030 Systematic N/A 4.1 0.2 SM-4 1480 Systematic N/A 2.4 0.2 SM-5 1250 Systematic N/A 0.6 3.5 SM-6 1100 Systematic N/A 4.4 3.5 SM-7 1130 Systematic N/A 2.7 3.5 SM-8 849 Systematic N/A 2.2 3.5 SM-9 8100 Systematic N/A 0.5 3.5 SM-10 1550 Systematic N/A 4.3 3.5 SM-11 1380 Systematic N/A Sample measurements are taken from the lower left corner of the surface on which they lie.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 20 of 45 Survey Unit PH-1-17 Room 7/8 - Floor Section #1 El r-Q 0 me* 0 ON Measure from this point PH-1-17*
AREA: PPH Room #718 - Floor Section #1 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.4 0.9 SM-1 70 Systematic N/A 3.6 0.9 SM-2 500 Systematic N/A 6.8 0.9 SM-3 394 Systematic N/A 9.9 0.9 SM-4 423 Systematic N/A 13.1 0.9 SM-5 120 Systematic N/A 16.3 0.9 SM-6 627 Systematic N/A 2.0 3.6 SM-7 472 Systematic N/A 5.2 3.6 SM-8 415 Systematic N/A 8.4 3.6 SM-9 268 Systematic N/A 11.5 3.6 SM-10 556 Systematic N/A 14.7 3.6 SM-11 310 Systematic N/A All of the sample measurements are taken from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 21 of 45 Survey Unit PH-1-18 Room 7/8 - Floor Section #2 000 a ~.0 0 I
0 a I I The 3 circles show the approximate location of irregularly shaped openings in the floor surface, which were made by overlapping 8" core bores. The rectangles represent the edges of the opening. *E990 D
C2 Measure from this point PH-1-18*
AREA: PPH Room #718 - Floor Section #2 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (ml) dpm/100-cm 2 Type Notes 2.0 1.3 SM-1 451 Systematic N/A 4.2 1.3 SM-2 423 Systematic N/A 0.9 3.2 SM-3 599 Systematic N/A 3.1 3.2 SM-4 563 Systematic N/A 2.0 5.1 SM-5 746 Systematic N/A 4.2 5.1 SM-6 606 Systematic N/A 0.9 7.0 SM-7 789 Systematic N/A 3.1 7.0 SM-8 775 Systematic N/A
-0.2 8.9 SM-9 648 Systematic N/A 2.0 8.9 SM-10 472 Systematic N/A 4.2 8.9 SM-1 1 599 Systematic N/A All of the sample measurements are taken from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 22 of 45 Survey Unit PH-1 -19 Room 7/8 - Floor Section #3 D)
- ffga tgIl The 3 circles show the approximate 0 location of irregularly shaped openings in the floor surface, which were made by overlapping 8" core bores. The rectangles represent the edges of the dli" opening.
0
--Iiul 1ý ý L' Measure from this point PH-1-19*
AREA: PPH Room #7/8 - Floor Section #3 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (mn dpm/1 00-cm 2 Type Notes 0.5 1.0 SM-1 346 Systematic N/A 2.6 1.0 SM-2 804 Systematic N/A 3.6 2.8 SM-3 889 Systematic N/A 0.5 4.6 SM-4 837 Systematic N/A 2.6 4.6 SM-5 915 Systematic N/A 1.5 6.5 SM-6 281 Systematic N/A 3.6 6.5 SM-7 320 Systematic N/A 0.5 8.3 SM-8 856 Systematic N/A 2.6 8.3 SM-9 1013 Systematic N/A 1.5 10.1 SM-10 412 Systematic N/A 3.6 10.1 SM-11 641 Systematic N/A All of the sample measurements are taken from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 23 of 45 Survey Unit PH-1-20 Room 8 - Sump N
t North-South Line SM_
Measure from this point North Line PH-1-20*
AREA: PPH Room #8 - Sump Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpml 00-cm 2 Type Notes 2.4 0.9 SM-1 556 Systematic N/A 4.8 0.9 SM-2 477 Systematic N/A 0.1 0.1 SM-3 654 Systematic N/A 0.7 0.5 SM-4 1033 Systematic N/A 3.2 0.5 SM-5 1176 Systematic N/A 0.1 0.5 SM-6 1183 Systematic N/A 1.0 2.6 SM-7 1020 Systematic N/A 2.3 2.6 SM-8 353 Systematic N/A 1.6 0.05 SM-9 647 Systematic N/A 4.0 0.05 SM-10 856 Systematic N/A 6.4 0.05 SM-1 1 601 Systematic N/A All of the sample measurements, except SM-3, are taken from the lower left corner, as shown on the folded out map, of the surface on which they rest. SM-3 is measured from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 24 of 45 Survey Unit PH-1-21 Room 7/8 - Wall Section #1 4L. I Measure SM -2 & 6 'I from this point Measure SM -3, 4, 7 & 8 0 from this point
/
Measure SM -5, 10, & 11 from this point LEIZI I EIIII Measure SM-9 from this point C-Jý Z-O Measure SM-1 from this point PH-1-21 AREA: PPH Room #7/8 - Wall Section 1 Measurement Locations and results Location i X Co-ord (m) Y Co-ord (m) dpm/1 00-cm2 Type Notes 0.05 0.3 SM-1 899 Systematic N/A 0.4 0.3 SM-2 532 Systematic N/A 2.3 0.3 SM-3 842 Systematic N/A 5.3 0.3 SM-4 646 Systematic N/A 2.1 1.5 SM-5 1010 Systematic N/A 1.9 2.8 SM-6 810 Systematic N/A 0.8 2.8 SM-7 835 Systematic N/A 3.8 2.8 SM-8 -146 Systematic N/A 0.1 4.1 SM-9 911 Systematic N/A 0.7 5.4 SM-10 487 Systematic N/A 2.1 6.6 SM-11 589 Systematic N/A
- All of the sample measurements are taken from the points shown on the map
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 25 of 45 Survey Unit PH-1-22 Room 7/8 - Wall Section #2 1,-Il TT~Tt SM MeasureSM-6, 7 & llfrom this point.
Measure SM-3, 4 & 8 Measure SM-I, 2,5,9 & 10 from this point.
from this point.
PH-1 -22 AREA: PPH Room #7/8 - Wall Section 2 Measurement Locations and results Location I X Co-ord (m) Y Co-ord (m) dpm/100-cm 2 Type Notes 0.5 0.5 SM-1 620 Systematic N/A 3.7 0.5 SM-2 646 Systematic N/A 1.6 3.2 SM-3 494 Systematic N/A 4.7 3.2 SM-4 690 Systematic N/A 2.1 3.2 SM-5 95 Systematic N/A 0.1 2.0 SM-6 652 Systematic N/A 3.3 2.0 SM-7 823 Systematic N/A 3.1 5.9 SM-8 13 Systematic N/A 0.5 5.9 SM-9 1050 Systematic N/A 3.7 5.9 SM-10 703 Systematic N/A 1.7 4.7 SM-11 703 Systematic N/A
- All of the sample measurements are taken from the points shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 26 of 45 Survey Unit PH-1-23 Room 7/8 - Wall Section #3 Measure SM -3, 7, 8, & 9 Measure SM -4, 5, 6, 10, from this point. & 11 from this point.
IIHIIII Measure SM -1 & 2 from this point.
PH-1-23 AREA: PPH Rooms #718 - Wall Section 3 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.6 0.5 SM-1 620 Systematic N/A 3.6 0.5 SM-2 506 Systematic N/A 6.0 0.8 SM-3 544 Systematic N/A 0.9 0.8 SM-4 690 Systematic N/A 4.0 0.8 SM-5 759 Systematic N/A 7.0 0.8 SM-6 563 Systematic N/A 1.4 3.4 SM-7 513 Systematic N/A 4.5 3.4 SM-8 620 Systematic N/A 7.5 3.4 SM-9 861 Systematic N/A 2.4 3.4 SM-10 108 Systematic N/A 5.5 3.4 SM-11 -57 Systematic N/A
- All of the sample measurements are taken from the points shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 27 of 45 Survey Unit PH-1-24 Room 7/8 - Wall Section #4 4
FSM4 SM-I
- .1-I. - 1 1' SM-ý PH-1-24 AREA: PPH Rooms #718 - Wall Section 4 Measurement Locations and results Location I X Co-ord (m) Y Co-ord (m) dpmll 00-cm2 Type Notes 1.5 0.7 SM-1 690 Systematic N/A 4.2 0.7 SM-2 671 Systematic N/A 2.7 0.7 SM-3 576 Systematic N/A 0.1 3.0 SM-4 905 Systematic N/A 2.8 3.0 SM-5 842 Systematic N/A 1.3 3.0 SM-6 975 Systematic N/A 4.0 3.0 SM-7 665 Systematic N/A 0.27 1.8 SM-8 734 Systematic N/A 0.27 1.8 SM-9 791 Systematic N/A 0.22 1.8 SM-10 759 Systematic N/A 0.23 1.8 SM-11 411 Systematic N/A II ofTthe sample measurements are taKen rrom me lower left corner OT me surface on wnicn they rest.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 28 of 45 Survey Unit PH-1-25 Room 7/8 - Wall Section #5
.00.a m
0 D 0 oý PH-1-26 AREA: PPH Rooms #718 - Wall Section 6 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.3 1.5 SM-1 972 Systematic N/A 3.4 1.5 SM-2 738 Systematic N/A 6.6 1.5 SM-3 681 Systematic N/A 9.7 1.5 SM-4 816 Systematic N/A 12.8 1.5 SM-5 674 Systematic N/A 16.0 1.5 SM-6 660 Systematic N/A 1.9 4.2 SM-7 560 Systematic N/A 5.0 4.2 SM-8 631 Systematic N/A 8.1 4.2 SM-9 596 Systematic N/A 11.3 4.2 SM-10 844 Systematic N/A 14.4 4.2 SM-11 525 Systematic N/A
- All of the sample measurements are taken from the lower left corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 29 of 45 Survey Unit PH-1-26 Room 7/8 - Wall Section #6
. 4" was~ 1 4, 0 0 0
,%..,.* '4....-l i 0 B Ia Zý SM-I PH-1-26 AREA: PPH Rooms #718 - Wall Section 6 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 1.5 0.4 SM-1 613 Systematic N/A 5.1 0.4 SM-2 655 Systematic N/A 8.7 0.4 SM-3 655 Systematic N/A 12.3 0.4 SM-4 655 Systematic N/A 3.3 3.5 SM-5 475 Systematic N/A 6.9 3.5 SM-6 614 Systematic N/A 10.5 3.5 SM-7 715 Systematic N/A 14.1 3.5 SM-8 734 Systematic N/A 1.5 6.6 SM-9 437 Systematic N/A 5.1 6.6 SM-10 1040 Systematic N/A 8.7 6.6 SM-11 835 Systematic N/A 12.3 6.6 SM-12 873 Systematic N/A
- All of the sample measurements are taken from the lower left corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 30 of 45 Survey Unit PH-1-27 Room 7 - Motor Platforms ISI I I-sm- QSMSM Li U USM-I ra 4J-W I Ismad
,Lk---flj PH-1-27 AREA: PPH Room #7 - Motor Platforms Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpml 00-cm 2 Type Notes 0.2 0.7 SM-1 404 Systematic N/A 0.5 0.7 SM-2 589 Systematic N/A 1.2 0.7 SM-3 582 Systematic N/A 2.0 0.7 SM-4 674 Systematic N/A 2.1 3.4 SM-5 773 Systematic N/A 2.8 3.4 SM-6 447 Systematic N/A 0.4 3.4 SM-7 355 Systematic N/A 0.1 1.7 SM-8 956 Systematic N/A 0.3 1.7 SM-9 1059 Systematic N/A 0.05 0.7 SM-10 625 Systematic N/A 0.05 1.1 SM-1 1 1070 Systematic N/A
- All of the sample measurements are taken from the lower left comer of the surface on which they rest (as shown on the map).
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 31 of 45 Survey Unit PH-1-28 Rooms 7/8 - Ceiling Section #1 0 =
r Measure SM-Il from this point 1 ~
1~i~o
-. 44 "1
I 1ii~
-~
IN3 a 4.* -
"ý 0 4..~!
IaLOI-II .1 E]
~SM~
T Measure SM-I thru 10 from this point E~Z1 L~2 PH-1-28 AREA: PPH Rooms #7/8 - Ceiling Section 1 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/ 00-cm 2 Type Notes 3.0 0.4 SM-1 823 Systematic N/A 7.0 0.4 SM-2 500 Systematic N/A 11.1 0.4 SM-3 987 Systematic N/A 15.2 0.4 SM-4 538 Systematic N/A 0.9 4.0 SM-5 1220 Systematic N/A 5.0 4.0 SM-6 987 Systematic N/A 9.1 4.0 SM-7 873 Systematic N/A 13.2 4.0 SM-8 994 Systematic N/A 17.2 4.0 SM-9 797 Systematic N/A 21.3 4.0 SM-10 728 Systematic N/A 0.1 2.7 SM-11 722 Systematic N/A
- All of the sample measurements are taken from the points shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 32 of 45 Survey Unit PH-1-29 Rooms 7/8 - Ceiling Section #2 M-11
- all 0
,IED Measure from this point PH-1-29*
AREA: PPH Rooms #718 - Ceiling Section 2 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.3 0.8 SM-i 441 Systematic N/A 3.4 0.8 SM-2 654 Systematic N/A 1.9 3.4 SM-3 684 Systematic N/A 0.3 6.0 SM-4 368 Systematic N/A 3.4 6.0 SM-5 493 Systematic N/A 1.9 8.7 SM-6 324 Systematic N/A 0.3 11.3 SM-7 456 Systematic N/A 3.4 11.3 SM-8 581 Systematic N/A 1.9 13.9 SM-9 868 Systematic N/A 0.3 16.5 SM-10 522 Systematic N/A 3.4 16.5 SM-11 632 Systematic N/A
- All of the sample measurements are taken from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 33 of 45 Survey Unit PH-1-30 Rooms 3 - Soil
%E,*I =,
PH-I-30*
AREA: PPH Rooms #3 -Soil Measurement Locations and results X Co-ord (m) Y Co-ord (m) Location Type Notes 0.1 0.4 SM-1 Systematic N/A 1.2 0.4 SM-2 Systematic N/A 2.3 0.4 SM-3 Systematic N/A 3.4 0.4 SM-4 Systematic N/A 0.7 1.3 SM-5 Systematic N/A 1.8 1.3 SM-6 Systematic N/A 2.9 1.3 SM-7 Systematic N/A 0.1 2.3 SM-8 Systematic N/A 1.2 2.3 SM-9 Systematic N/A 2.3 2.3 SM-10 Systematic N/A 3.4 2.3 SM-11 Systematic N/A
- All of the sample measurements are taken from the southwest corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 34 of 45 Survey Unit PH-2-1 Roof - Section #1 F-I I-1 LI I--- I---T -
0 *M 0 *R o E I*I LI El 111ýn) 0 rn PH-2-1*
AREA: PPH Roof - Section #1 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm2 Type Notes 1.1 1.1 SM-1 281 Systematic N/A 7.6 1.1 SM-2 706 Systematic N/A 10.8 1.1 SM-3 144 Systematic N/A 14.0 1.1 SM-4 118 Systematic N/A 17.2 1.1 SM-5 137 Systematic N/A 2.7 3.9 SM-6 948 Systematic N/A 6.0 3.9 SM-7 497 Systematic N/A 9.2 3.9 SM-8 843 Systematic N/A 12.4 3.9 SM-9 680 Systematic N/A 15.6 3.9 SM-10 817 Systematic N/A 18.8 3.9 SM-11 654 Systematic N/A
- All of the sample measurements are taken from the southwest corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 35 of 45 Survey Unit PH-2-2 Roof - Section #2 PH-2-2*
AREA: PPH Roof - Section #2 Measurement Locations and results Location I X Co-ord (m) Co-ord (m) dpmll00-cm 2 Type Notes 1.2 0.4 SM-1 131 Systematic N/A 4.5 0.4 SM-2 752 Systematic N/A 2.9 3.2 SM-3 26 Systematic N/A 1.2 6.0 SM-4 412 Systematic N/A 4.5 6.0 SM-5 837 Systematic N/A 2.9 8.8 SM-6 137 Systematic N/A 1.2 11.6 SM-7 124 Systematic N/A 4.5 11.6 SM-8 1301 Systematic N/A 2.9 14.3 SM-9 418 Systematic N/A 1.2 17.1 SM-10 52 Systematic N/A 4.5 17.1 SM-11 974 Systematic N/A
- All of the sample measurements are taken from the southwest corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 36 of 45 Survey Unit PH-2-3 Roof - Section #3 PH-2-3*
AREA: PPH Roof - Section #3 Measurement Locations and results Location I X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.5 0.6 SM-1 566 Systematic N/A 3.2 0.6 SM-2 401 Systematic N/A 6.0 0.6 SM-3 1059 Systematic N/A 8.7 0.6 SM-4 888 Systematic N/A 0.5 5.3 SM-5 809 Systematic N/A 3.2 5.3 SM-6 816 Systematic N/A 8.7 5.3 SM-7 1382 Systematic N/A 1.9 7.7 SM-8 612 Systematic N/A 4.6 7.7 SM-9 520 Systematic N/A 7.3 7.7 SM-10 941 Systematic N/A 0.2 0.05 SM-1 1 1842 Systematic N/A
- Sample measurements are from the southwest corner of the survey unit, except SM-11, which is measured from the point shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 37 of 45 Survey Unit PH-2-4 Roof - Section #4 0 0 0 PH-2-4*
AREA: PPH Roof - Section #4 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 0.8 0.25 SM-1 980 Systematic N/A 0.3 Center SM-2 678 Systematic N/A 0.0 0.3 SM-3 2862 Systematic N/A Edge 1.4 SM-4 974 Systematic N/A 3.5 1.4 SM-5 1020 Systematic N/A 7.0 1.4 SM-6 914 Systematic N/A 5.3 4.4 SM-7 1145 Systematic N/A 8.8 4.4 SM-8 671 Systematic N/A Edge 7.4 SM-9 572 Systematic N/A 3.5 7.4 SM-10 316 Systematic N/A 7.0 7.4 SM-11 586 Systematic N/A
- Sample points 1, 2, & 3 are measured from the points shown on the map. The remaining samples are measured from the southwest corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 38 of 45 Survey Unit PH-2-5 Roof - Section #5
'SMa1 a *30 oEllF PH-2-5*
AREA: PPH Roof - Section #6 Measurement Locations and results Location I X Co-ord (m) Co-ord rm) dpm/100-cm 2 Type Notes 1.2 1.5 SM-1 191 Systematic N/A 4.3 1.5 SM-2 796 Systematic N/A 7.5 1.5 SM-3 -125 Systematic N/A 5.9 4.2 SM-4 586 Systematic N/A 9.0 4.2 SM-5 895 Systematic N/A 1.2 6.9 SM-6 322 Systematic N/A 4.3 6.9 SM-7 7 Systematic N/A 7.5 6.9 SM-8 507 Systematic N/A 2.8 9.7 SM-9 230 Systematic N/A 5.9 9.7 SM-10 757 Systematic N/A 9.0 9.7 SM-11 770 Systematic N/A
- All of the sample measurements are taken from the southwest corner of the survey unit.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 39 of 45 Survey Unit PH-2-6 Roof - Section #6 D
D nZZ PH-2-6*
AREA: PPH Roof - Section #6 Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/100-cm 2 Type Notes 0.6 Center SM-1 850 Systematic N/A
-7.1 -0.1 SM-2 1170 Systematic N/A
-4.0 -0.1 SM-3 902 Systematic N/A
-0.9 -0.1 SM-4 804 Systematic N/A
-8.6 2.6 SM-5 856 Systematic N/A
-5.5 2.6 SM-6 804 Systematic N/A
-2.4 2.6 SM-7 1105 Systematic N/A
-7.1 5.3 SM-8 739 Systematic N/A
-0.9 5.3 SM-9 529 Systematic N/A
-8.6 7.9 SM-10 725 Systematic N/A
-2.4 7.9 SM-11 418 Systematic N/A
- Sample measurements are from the points shown on the map.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 40 of 45 Survey Unit PH-2-7 Primary Pump House Exterior - Lower South Wall PH-2-7*
AREA: PPH Exterior - Lower South Wall Measurement Locations and results Location I X Co-ord (m) Y Co-ord (im) dpm/100-cm2 Type Notes 13.2 -0.6 SM-1 1307 Systematic N/A 15.6 -0.6 SM-2 510 Systematic N/A 17.9 -0.6 SM-3 2784 Systematic N/A 0.2 1.4 SM-4 745 Systematic N/A 2.6 1.4 SM-5 889 Systematic N/A 9.7 1.4 SM-6 451 Systematic N/A 12.0 1.4 SM-7 386 Systematic N/A 14.4 1.4 SM-8 556 Systematic N/A 16.7 1.4 SM-9 549 Systematic N/A 19.1 1.4 SM-10 392 Systematic N/A 21.5 1.4 SM-11 190 Systematic N/A Sample measurements are from me lower left corner OT me wall surface on wnich tney rest.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 41 of 45 Survey Unit PH-2-8 Primary Pump House Exterior - Upper South Wall PH-2-8*
AREA: PPH Exterior - Upper South Wall Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpmll 00-cm 2 Type Notes 0.6 2.3 SM-1 447 Systematic N/A 8.7 2.3 SM-2 368 Systematic N/A 12.8 2.3 SM-3 408 Systematic N/A 16.9 2.3 SM-4 612 Systematic N/A 21.0 2.3 SM-5 711 Systematic N/A 2.6 5.8 SM-6 336 Systematic N/A 6.7 5.8 SM-7 743 Systematic N/A 10.8 5.8 SM-8 526 Systematic N/A 14.9 5.8 SM-9 1125 Systematic N/A 18.9 5.8 SM-10 507 Systematic N/A 23.0 5.8 SM-11 737 Systematic N/A
- Sample measurements are from the lower left corner of the wall surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 42 of 45 Survey Unit PH-2-9 Primary Pump House Exterior - Lower East Wall 4 4. 4 4 4 4 +
- Eilj *hiia *R, W 09 Oku1 .lii~I *ffE PH-2-9*
AREA: PPH Exterior - Lower East Wall Measurement Locations and results Location I X Co-ord (m) Y Co-ord (m) dpmllOO-cm 2 Type Notes 1.6 1.0 SM-1 732 Systematic N/A 3.4 1.0 SM-2 373 Systematic N/A 5.1 1.0 SM-3 222 Systematic N/A 6.9 1.0 SM-4 144 Systematic N/A 8.7 1.0 SM-5 405 Systematic N/A 10.5 1.0 SM-6 209 Systematic N/A 12.3 1.0 SM-7 248 Systematic N/A 14.1 1.0 SM-8 373 Systematic N/A 15.9 1.0 SM-9 477 Systematic N/A 17.7 1.0 SM-10 464 Systematic N/A 21.3 1.0 SM-11 314 Systematic N/A
- Sample measurements are from the lower left corner of the wall surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 43 of 45 Survey Unit PH-2-10 Primary Pump House Exterior - Upper East Wall
__* Ao -~
--- Eta PH-2-10*
AREA: PPH Exterior - Upper East Wall Measurement Locations and results Location /
X Co-ord (m) YCo-ord (m) dpm/100-cm 2 Type Notes 2.4 2.1 SM-1 -92 Systematic N/A 6.2 2.1 SM-2 132 Systematic N/A 10.1 2.1 SM-3 -151 Systematic N/A 14.0 2.1 SM-4 750 Systematic N/A 17.8 2.1 SM-5 559 Systematic N/A 21.7 2.1 SM-6 507 Systematic N/A 0.4 5.5 SM-7 500 Systematic N/A 4.3 5.5 SM-8 789 Systematic N/A 8.2 5.5 SM-9 539 Systematic N/A 12.0 5.5 SM-10 809 Systematic N/A 15.9 5.5 SM-1 1 803 Systematic N/A 19.8 5.5 SM-12 507 Systematic N/A
- Sample measurements are from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 44 of 45 Survey Unit PH-2-11 Primary Pump House Exterior - Lower North Wall MW I W- I 1 PH-2-11*
AREA: PPH Exterior - Lower North Wall Measurement Locations and results Location I X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 1.3 0.5 SM-1 601 Systematic N/A 0.3 Edge SM-2 843 Systematic N/A 1.1 1.2 SM-3 948 Systematic N/A 3.5 1.2 SM-4 641 Systematic N/A 5.9 1.2 SM-5 595 Systematic N/A 8.4 1.2 SM-6 614 Systematic N/A 10.8 1.2 SM-7 314 Systematic N/A 13.3 1.2 SM-8 150 Systematic N/A 15.7 1.2 SM-9 778 Systematic N/A 18.1 1.2 SM-10 72 Systematic N/A 20.6 1.2 SM-11 39 Systematic N/A
- Sample measurements are from the lower left corner of the surface on which they rest.
Plum Brook Reactor Facility FSSR, Attachment 13 Appendix B Rev. 0, Page 45 of 45 Survey Unit PH-2-12 Primary Pump House Exterior - Upper North Wall PH-2-12*
AREA: PPH Exterior - Upper North Wall Measurement Locations and results Location /
X Co-ord (m) Y Co-ord (m) dpm/1 00-cm 2 Type Notes 2.3 2.2 SM-1 461 Systematic N/A 6.5 2.2 SM-2 224 Systematic N/A 10.8 2.2 SM-3 645 Systematic N/A 15.0 2.2 SM-4 368 Systematic N/A 19.2 2.2 SM-5 539 Systematic N/A 0.2 5.8 SM-6 289 Systematic N/A 4.4 5.8 SM-7 1270 Systematic N/A 8.6 5.8 SM-8 1026 Systematic N/A 12.9 5.8 SM-9 1086 Systematic N/A 17.1 5.8 SM-10 691 Systematic N/A 21.3 5.8 SM-11 546 Systematic N/A
- Sample measurements are from the lower left corner of the wall surface on which they rest.