Text
November 10, 2011 l\\1r. Jeremy Tapp U. S. Nuclear Regulatory Commission Region III 2443 Warrenville Road Lisle, IL 60532-4351 ORISE CONTRACT NO. DE-AC05-060R23100
SUBJECT:
LETTER REPORT FOR ANALYTICAL RESULTS FOR EIGHT SOIL SAMPLES AND ONE WATER SAMPLE FROM NASA PLUM BROOK, SANDUSKY, OHIO
[INSPECTION REPORT NOS. 05000030/2012-001; 05000185/2012-001]
(RFTA NO.12-001)
DCN: 5159-LR-01-0
Dear Mr. Tapp:
The Oak Ridge Institute for Science and Education (aRISE) received eight soil samples and one water sample on October 24, 2011 from NASA Plum Brook in Sandusky, Ohio. The samples were analyzed according to the NRC 303 form supplied with the samples. The sample identification numbers are presented in Table 1. The gamma spectroscopy results for cobalt-60 and cesium-137 are presented in Table 2. Strontium-90 and tritium results are presented in Tables 3 and 4, respectively. The pertinent procedure references are included with the data tables.
aRISE's Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request.
My contact information is listed below. You may also contact Dale Condra at 865.241.3242 with any questions or comments.
Sincerely,
!f~,~i:7 Laboratory WPI:RDC:bj Enclosures c:
T. Carter, NRC/FSME/DWMEP T-8F5 S. Nesmith, NRC/FSME/PBPA/TWFN 8A23 File 5159 Electronic:
S. Roberts, ORISE T. Vitkus, ORISE RECEIVED NOV 1 7 2011 Voice: 865.576.9184 Fax: 865.241.3248 E-mail: Wade.Ivey@orau.org P.O. Box 117 I Oak Ridge. TN 37831 I www.onse.orau.gov
TABLE 1 SAMPLE IDENTIFICATION.
AND COLLECTION DATA NASA PLUM BROOK SANDUSKY, OHIO ORISE Sample ID NRC Region III SampleID Collection Date Collection Time 5159S0001 NPB-11-1-01 10/18/2011 10:35 5159S0002
~-PB-11-1-02 10/18/2011 10:55 5159S0003 NPB-11-1-03 10/18/2011 12:35 5159S0004 NPB-11-1-04 10/18/2011 12:45 5159S0005 NPB-11-1-05 10/18/2011 16:05 5159S0006 NPB-11-1-06 10/19/2011 10:20 5159S0007 NPB-11-1-07 10/19/2011 12:15 5159S0008 NPB-11-1-08 10/20/2011 11:35 5159WOO01 NPB-11-1-09 10/18/2011 16:20 NASA Plum Brook 5159-LR-OI-0
TABLE 2 CONCENTRATIONS OF SELECTED GAMMA EMMITTING RADIONUCLIDES IN SOIL SAMPLES BY GAMMA SPECTROSCOPY CP1, REVISION 17 NASA PLUM BROOK SANDUSKY, OHIO ORISE Sample ID NRC Region III SampleID Radionuclide Concentrations, TPUs a
, and MDCsb (PCilg)
Cs-137 Co-60 5159S0001 NPB-II-I-01 0.22 +/- 0.04,
0.05 0.03 +/- 0.06, 0.10 5159S0002 NPB-I1-1-02 0.03 +/- 0.01,
0.03 O.OOc +/- 0.05, 0.07 5159S0003 NPB-I1-1-03 0.02 +/- 0.01,
0.03
-0.05 +/- 0.05, 0.07 5159S0004 NPB-II-1-04 1.75 +/- 0.14,
0.05 0.03 +/- 0.01
, 0.06 5159S0005 NPB-I1-1-05 0.32 +/- 0.04, 0.04 0.03 +/- 0.05, 0.09 5159S0006 NPB-II-I-06 0.13 +/- 0.02, 0.03 0.02 +/- 0.04, 0.07 5159S0007 NPB-I1-1-07 2.76 +/- 0.21,
0.06 0.11 +/- 0.03
, 0.05 5159S0008 NPB-II-I-08 0.13 +/- 0.02,
0.03 0.01 +/- 0.04, 0.07
- Uncertainties represent the 95% confidence level, based on total propagated uncertainties.
bThe MDCs appear after the commas.
'Zero values are due to rounding or sample and background having equal counts.
NASA Plum Brook 5159-LR-OI-0
TABLE 3 CONCENTRATIONS OF TOTAL STRONTIUM IN SOIL SAMPLES BY TOTAL DISSOLUTION AP4, REVISION 15 NASA PLUM BROOK SANDUSKY, OHIO ORISE Sample ID NRC Region III Sample ID Total Sr Concentrations, TPUs a
, and MDCs b
(PCi/g) 5159S0001 NPB-ll-l-0l 0.04 +/- 0.20, 0.36 5159S0002 NPB-ll-1-02 0.19
+ 0.20, 0.34 5159S0003 NPB-11-1-03 0.22 +/- 0.22, 0.37 5159S0004 NPB-l1-1-04 0.24 +/- 0.22, 0.36 5159S0005 NPB-11-1-05 0.24 +/- 0.21, 0.35 5159SOO06 NPB-ll-l-06 0.10 +/- 0.20, 0.36 5159S0007 NPB-l1-1-07 0.29 +/- 0.23, 0.38 5159S0008 NPB-ll-l-08 0.37
+ 0.25 0040
'Uncertainties represent the 95% confidence level, based on total propagated uncertainties.
bThe MDCs appear after the commas.
NASA Plum Brook 51S9-LR-Ot-O
TABLE 4 CONCENTRATION OF TRITIUM IN A WATER SAMPLE BY DISTILLATION AP2, REVISION 17; CP4 REVISION 4 NASA PLUM BROOK SANDUSKY, OHIO Tritium ORISE SampieID NRC Region III SampieID Concentration, TPUa,
and MDCb (PCi/L) 5159WOO01 NPB-11-1-09
-40 +/- 160 282 aUncertainty represents the 95% confidence level, based on total propagated uncertainties.
bThe MDe appears after the comma.
NASA Plumb Brook 5159-LR-OI-0