NG-11-0350, 10 CFR 50.46 Annual Report of Changes in Peak Cladding Temperature

From kanterella
(Redirected from ML112730041)
Jump to navigation Jump to search
10 CFR 50.46 Annual Report of Changes in Peak Cladding Temperature
ML112730041
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 09/30/2011
From: Wells P
NextEra Energy Duane Arnold
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
NG-11-0350
Download: ML112730041 (2)


Text

NEXTera M ENERGY~

/ DUANE """'"

ARNOLD September 30,2011 NG-11-0350 10 CFR 50.46(a)(3)(ii)

U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Duane Arnold Energy Center Docket 50-331 License No. DPR-49 10 CFR 50.46 Annual Report of Changes in Peak Cladding Temperature for the Duane Arnold Energy Center

References:

1) Letter from C. Costanzo (NextEra Energy Duane Arnold) to USNRC, "10 CFR 50.46 Annual Report of Changes in Peak Cladding Temperature for the Duane Arnold Energy Center," NG-10-0480, dated September 30,2010.
2) Letterfrom P. Wells (NextEra Energy Duane Arnold) to USNRC, "10 CFR 50.4630-Day Special Report of Changes in Peak Cladding Temperature for the Duane Arnold Energy Center," NG-11-0289, dated August 18, 2011.

In accordance with 10 CFR 50.46(a)(3)(ii), NextEra Energy Duane Arnold, LLC (hereafter NextEra Energy Duane Arnold) hereby provides the annual report regarding the changes in the calculated peak cladding temperature (PCT) of the GE14 fuel currently utilized at the Duane Arnold Energy Center (DAEC). This report covers the period from the last annual report (Reference 1) through August 31, 2011.

Our fuel vendor has notified NextEra Energy Duane Arnold that no changes or errors in the current Loss-of-Coolant Accident analysis methodology have occurred subsequent to those reported in Reference 2. Enclosed is a historical summary of previously reported errors.

Pe ells Vice President, Duane Arnold Energy Center NextEra Energy Duane Arnold, LLC Enclosure NextEra Energy Duane Arnold, LLC, 3277 DAEC Road, Palo, IA 52324

Enclosure to NG-11-0350 September 30, 2011 10 CFR 50.46 ANNUAL REPORT for DAEC - 2011 Peak Cladding Temperature(1)

Last Acceptable Model Results(2): 1510°F Previously Reported Errors and Changes:

2001 - 2010(3): +65°F New Errors and Changes(3): +50°F Analysis of Record Results: 1625°F (1) Licensing Basis PCT (LBPCT), as defined in NEDE-23785-1-P-A, The GESTR-LOCA and SAFER Models for the Evaluation of the Loss-of-Coolant Accident:

Volume III - SAFER/GESTR Application Methodology, February 1985.

(2) General Electric Report, Safety Analysis Report for Duane Arnold Energy Center Extended Power Uprate, NEDC-32980P, Revision 1, April 2001.

(3) Evaluations of each reported error have concluded that re-analysis was not required.