ML112630673

From kanterella
Jump to navigation Jump to search

Email, NRC Staff Questions, Loss-of-Coolant Accident Frequency Analysis, Resolution Approach for Risk-Informed GSI-191, Assessment of Debris Accumulation on Pressurized-Water Reactor (PWR) Sump Performance.
ML112630673
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 09/20/2011
From: Balwant Singal
Plant Licensing Branch IV
To: Paul J
South Texas
Singal, Balwant, 415-3016, NRR/DORL/LPL4
Shared Package
ML112630671 List:
References
TAC ME5358, TAC ME5359, GSI-191
Download: ML112630673 (1)


Text

From: Singal, Balwant Sent: Tuesday, September 20, 2011 4:05 PM To: Paul, Jamie Cc: Grantom, Carl; Bailey, Stewart; Tregoning, Robert; Tsao, John; Thadani, Mohan

Subject:

U. S. Nuclear Regulatory Commission (NRC) Staff Questions - Topic of Loss-of-Coolant Accident (LOCA) Frequency Analysis - Risk-Informed Approach to GSAI-191, TACs ME5358 and ME5359 Attachments: Questions Associated with LOCA Frequency Analysis.docx Jamie:

Based on our discussions this morning attached are the NRC staff questions on the topic of LOCA Frequency Analysis for the proposed Risk-Informed Approach for resolution to GSI-191 issues The NRC staff expects that STP Nuclear Operating Company will address these questions during the forthcoming presentation during the conference call public meeting on October 3, 2011. Please let me know if you have questions.

I will be out-of-office next week. Please call my backup Project Manager, Mohan Thadani at 301-415-1476 during my absence.

Thanks.

Balwant K. Singal Senior Project Manager (Comanche Peak and STP)

Nuclear Regulatory Commission Division of Operating Reactor Licensing Balwant.Singal@nrc.gov Tel: (301) 415-3016 Fax: (301) 415-1222