IOWA ELECTRIC LIGHT AND POWER COMPANY DUANE ARNOLD ENERGY CENTER Reactor Containment Building Integrated Leakage Rate Test Types A, B, and C Periodic Test September 1993 9401120159 931220 2
PDR ADOCK 05000331 P
PDR 460
TABLE OF CONTENTS SECTION 1.0 1.1 1.2 2.0 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 4.0 4.1 4.2 4.3 TITLE Table of Contents List of Attachments References PURPOSE General Data Technical Data TYPE A TEST
SUMMARY
TYPE A TEST RESULTS Type A Test Data Analysis and Interpretation Instrumentation System Temperature Stabilization As Left Containment Type A Test As Found Containment Type A Test Verification Test Reduced Data LOCAL LEAKAGE RATE TESTS (Type B and C)
Leakage Penalties Added to Type A Leakage Water Level Corrections Total Corrections i
PAGE i
a 1
1 1
2 4
4 4
5 5
6 6
7 7
8 8
9 9
ATTACHMENT S1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 LIST OF ATTACHMENTS TITLE Table A - Test Setup Data Table B - Dry Bulb Temperature Sensor Readings Table C - Dew Point Temperature Sensor Readings Table D - Pressure Sensor Readings Table 4 - Containment Temperature Stability Parameters Table 4a - Containment Mass Point Leakage Stability Table 2 - Type A Test Leakage and Error Parameters Table 3 - Verification Test Parameters ILRT Instrumentation List ILRT Temperature Detector Locations ILRT Dewpoint Temperature Sensor Locations Graph - Containment Stabilization Containment Air Mass Graph - Containment Stabilization Mass Point Sliding Graph - Type A Test Total Time Leakage Rate and UCL Graph - Verification Test Total Time Leakage Rate Table 1 - ILRT Containment Air Mass Calculation Parameters 1993 Local Leakage Rate Test Data 1992 Local Leakage Rate Test Data Drywell Airlock Test Data Mid-cycle LLRT Data Since RFO-10 Ui
REFERENCES
- 1.
10CFR Part 50, Appendix J, Primary Reactor Containment Leakage Testing for Water Cooled Power Reactors, January 1, 1993.
- 2.
STP No. 47A002, Primary Containment Integrated Leakage Rate Test, Duane Arnold Energy Center, Surveillance Test Procedure.
- 3.
ANSI N45.4, American National Standard, Leakage-Rate Testing of Containment Structures for Nuclear Reactors, March 16, 1972.
- 4.
ANSI/ANS-56.8, Containment System Leakage Testing Requirements, January 20, 1987.
- 5.
Bechtel Corporation's Testing Criteria for Integrated Leakage Rate Testing of Primary Containment Structures for Nuclear Power Plants, BN-TOP-1, Revision 1, November 1, 1972.
- 6.
STP No. 47A003, Containment Leak Tightness Test - Type B Penetrations, Duane Arnold Energy Center, Surveillance Test Procedure.
- 7.
STP No. 47A004, Airlock Local Leak Rate Test, Duane Arnold Energy Center, Surveillance Test Procedure.
- 8.
STP No. 47A005, Containment Isolation Valve Leak Tightness Test - Type C Penetrations, Duane Arnold Energy Center, Surveillance Test Procedure.
- 9.
IE Information Notice No. 85-71: Containment Integrated Leak Rate Tests, August 22, 1985.
Xi
Iowa Electric Light & Power Duane Arnold Energy Center September, 1993 ILRT/LLRT Results 1.0 PURPOSE The purpose of this report is to present a description and analysis of the September 1993, Periodic Type A Primary Containment Integrated Leakage Rate Test (ILRT) and a summary of the Periodic Types B and C Local Leakage Rate Tests (LLRT's) conducted at Duane Arnold Energy Center (DAEC).
Duane Arnold Energy Center is operated by the Iowa Electric Light and Power Company. Plant specific information and technical data is contained below.
This report has been submitted to the United States Nuclear Regulatory Commission in accordance with the requirements of 10CFR50, Appendix J,Section V, Paragraphs B1 and B3. The form and content of this report is presented in accordance with ANSI/ANS 56-8, "Containment System Leakage Testing Requirements".
1.1 General Data Operator Iowa Electric Light and Power Plant Duane Arnold Energy Center Location Palo, Iowa Containment Type Mark I, BWR-4 Docket Number 50-331 Operating License No.
DPR-49 Date Test Completed September 20, 1993 1.2 Technical Data Containment Net Free Air Volume 230,000 cubic feet Design Pressure 56 psig Calculated Peak Accident Pressure 43 psig Containment Design Temperature 281 oF Page 1
Iowa Electric Light & Power Duane Arnold Energy Center September, 1993 ILRT/LLRT Results 2.0 TYPE A TEST
SUMMARY
, Table A - Test Setup Data contains the instrumentation and associated volume fractions list for all of the ILRT instruments. Attachments 2, 3, and 4 provide the raw data input tables for Dry Bulb Temperature, Dew Point Temperature and Pressure readings respectively.
2.1 Pressurization 2.2 Stabilization 2.3 Type A Test Containment pressurization was begun at approximately 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> on September 19, 1993. Pressurization rate was approximately 6.0 psi/hour. Investigations of all accessible penetrations were performed throughout the pressurization and Type A test. No leaks were identified.
Final containment test pressure was achieved at 0250 hours0.00289 days <br />0.0694 hours <br />4.133598e-4 weeks <br />9.5125e-5 months <br /> on September 20, 1993.
Containment stabilization was begun at approximately 0300 on Sepember 20, 1993. Pressure, temperature, and dew point data were recorded at 5 minute intervals during stabilization. The temperature and leakage stablilization criteria of ANSI/ANS 56-8 were met and the containment was declared stable at 0730 on September 20, 1993. Attachment 5, Containment Temperature Stability Parameters and Attachment 6, Containment Mass Point Leakage Stability provide the containment stability parameters.
The start of the Type A test was declared at 0745 on September 20, 1993. Pressure, temperature and dew point data were recorded at 15 minute intervals throughout the Type A test. The test proceeded without incident and was successfully completed at 1545 on September 20, 1993 with a Total Time Upper Confidence Limit (UCL-TT) of 0.15356 percent/day and Mass Point Upper Confidence Limit of 0.08282 percent per day.
Both Total Time and Mass Point leakage rates were below the 0.75La acceptance criteria. The Type A Test leakage and error parameters are depicted in tabular form in Attachment 7, Type A Test Leakage and Error Parameters.
Page 2
Iowa Electric Light & Power Duane Arnold Energy Center September, 1993 ILRT/LLRT Results 2.4 Verification Test 2.5 Depressurization The superimposed leakage verification test was started at 1630 hours0.0189 days <br />0.453 hours <br />0.0027 weeks <br />6.20215e-4 months <br /> on September 20, 1993. A one-hour stabilization period was implemented in accordance with BN-TOP-1. The test was successfully completed at 2130 hours0.0247 days <br />0.592 hours <br />0.00352 weeks <br />8.10465e-4 months <br /> on September 20, 1993. Attachment 8, Verification Test Parameters provides the upper and lower limits as well as the composite leakage for the verification test period.
After performing a radiological survey, the containment was depressurized over a period of approximately 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />.
NOTE No repairs or adjustments were made to the containment boundary either during the conduct of the Type A test or the Superimposed Leakage Verification test.
Page 3
Iowa Electric Light & Power Duane Arnold Energy Center September, 1993 ILRT/LLRT Results 3.0 TYPE A TEST RESULTS 3.1 Type A Test Data 3.1.1 Test Method: Absolute Method 3.1.2 Data Analysis Technique: Total time analysis method in accordance with BN-TOP-1, "Testing Criteria for Integrated Leakage Rate Testing of Primary Containment Structures for Nuclear Power Plants", Revision 1, November, 1972.
3.1.3 Test Pressure:
Between 44.0 psig and 45.0 psig.
3.1.4 Maximum Allowable Leakage Rate 0.75La (%/24 hours):
1.5 %/day 3.1.5 Calculated Leakage Rate Upper Confidence Limit (UCL):
0.15356 %/day 3.1.6 Measured Leakage Rate (Lam):
0.08080 %/day 3.2 Analysis and Interpretation 3.2.1 Acceptance Criteria: Based on Duane Arnold Technical Specification, the primary containment overall integrated leakage rate shall be maintained less than or equal to 0.75 La, where La is 2.0 % by weight of the containment air per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> at Pa, 43.0 psig. 10CFR50 Appendix J,Section III A.5.b, requires that the measured/calculated leakage rate shall be less than.75 La, or 1.5
%/day as determined by the Type A test. This is interpreted to mean that the upper confidence limit (UCL) on the measured leakage rate, including all Type B and C corrections, penalties, and other leakage additions, shall be less than the above acceptance criteria. Further, a verification test using the calibrated superimposed leakage method shall be performed and satisfy the following condition:
(Lo + Lam - 0.25 La) 5 Lc 5 (Lo + Lam + 0.25 La) where; Lo = Superimposed Leakage rate which is between 75% and 125% of La, Lam = Last valid Type A measured/calculated leakage rate, Lc = Composite leakage rate as measured by the data acquisition system during the verification test, La = Maximum allowable leakage rate at pressure Pac.
Page 4
Iowa Electric Light & Power Duane Arnold Energy Center September, 1993 ILRT/LLRT Results 3.3 Instrumentation System The test instrumentation system consisted of: (1) a microprocessor controlled data acquisition system (DAS); (2) fifteen drybulb resistance temperature detectors; (3) six dewpoint temperature sensors; and (4) two precision pressure gauges. Prior to containment pressurization, the calculated instrumentation system Instrument Selection Guide (ISG) was 0.034 %/day for an assumed eight hour test duration (refer to Attachment 1, Test Setup Data). This value was well below the required value of 0.5 %/day (0.25La). For testing purposes, the precision pressure gauge connected to the drywell was used.
After pressurizing the containment, and during temperature stabilization, it was determined that the Torus atmosphere was saturated and the dewcells located in the torus were reading higher than the drybulb temperature. It was decided, therefore to use the torus drybulb temperature sensors associated with these dewcells as the measure of dew point temperature. The ISG calculation was not affected.
The instrumentation system configuration at the beginning and end of the test was:
Drybulb RTD Sensors:
15 Dewpoint Temperature Sensors 6
Precision Pressure Manometers 1
Mass Flow Meters 1, ILRT Instrumentation List provides a description of instrument identification numbers and locations. Attachments 10 and 11 provide the Temperature and Dewpoint Sensor Zone locations respectively.
3.4 Temperature Stabilization The temperature stabilizaton period was begun after reaching a containment pressure of 58.98 psia. The containment atmosphere was allowed to stabilize for approximately 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> and 30 minutes. The latest rate of drybulb temperature change over the last hour of the stabilization was 0.012 oF. The average rate of change over the last four hours of the stabilization period was 0.106 oF, indicating a very stable containment atmosphere. This difference of 0.094 oF met the ANSI/ANS 56.8 requirement for temperature stabilization.
Further, the Containment Air Mass versus Time plot, Attachment 12 and the Mass Point Sliding Leakage Plot, Attachment 13 indicated a linear relationship confirming containment atmosphere stability.
Page 5
Iowa Electric Light & Power Duane Arnold Energy Center September, 1993 ILRT/LLRT Results 3.5 As Left Containment Type A Test The Type A Test was begun at 0745 hours0.00862 days <br />0.207 hours <br />0.00123 weeks <br />2.834725e-4 months <br /> on September 20, 1993. Based on the Total Time Analysis Method, the test was declared over at 1545 hours0.0179 days <br />0.429 hours <br />0.00255 weeks <br />5.878725e-4 months <br /> on September 20, 1993. The following summarizes the as left containment test results:
3.5.1 Type B and C Pre Test Penalty Leakage for penetrations not vented/drained 3.5.2 Type B and C Pre Test Penalty Leakage for penetrations isolated during the test 3.5.3 Water Level Corrections 3.5.4 Total Time UCL 0.04550 %/day 0.00000 %/day 0.05506 %/day 0.15356 %/day Total Time Acceptance = 3.5.1+3.5.2+3.5.3+3.5.4 5 0.75La
= 0.25412 %/day : 1.50 %/day 4 illustrates the Total Time calculated leakage rate and associated upper confidence limit over the test interval. Based on the above data, it was concluded that the as left containment leakage rate was stable, well below the acceptance criteria, and therefore the containment may be declared operable in accordance with the plant Technical Specifications.
3.6 As Found Containment Type A Test As suggested by Reference 9, the Type A Test results should be compensated for the "as found" vs. "as left" leakages for all penetrations if Type B and C repairs and adjustments are made prior to the Type A Test. This correction was equal to 0.2567 %/day. The following summarizes the as found containment results:
3.6.1 As Left Total Time Leakage Rate 3.6.2 As Found vs. as Left Leakage Correction 0.25412 %/day 0.2567 %/day Total Time Acceptance = 3.6.1 + 3.6.2 5 0.75 La
= 0.51082 %/day : 1.5 %/day Based on the above test results, it was concluded that the as found containment leakage rate was well below the acceptance criteria.
Page 6
Iowa Electric Light & Power Duane Arnold Energy Center September, 1993 ILRT/LLRT Results 3.7 Verification Test The superimposed leakage verification test was started at 1630 hours0.0189 days <br />0.453 hours <br />0.0027 weeks <br />6.20215e-4 months <br /> on September 20, 1993.The superimposed leakage rate was 12.2 SCFM. A one hour stabilization period was implemented in accordance with BN-TOP-1. The test was completed at 2130 hours0.0247 days <br />0.592 hours <br />0.00352 weeks <br />8.10465e-4 months <br /> on September 20, 1993. The following summarizes the verification test results:
3.7.1 Superimposed Leakage Rate (Lo) 1.97640 %/day 3.7.3 Composite Leakage Rate Total Time (Lc) 2.05236 %/day 3.7.5 Type A Test Leakage Rate Total Time (Lam) 0.08080 %/day The Superimposed Leakage Verification is acceptable provided Lc falls within the following ranges:
(Lam + Lo - 0.25La) s Lc : (Lam + Lo + 0.25La) 3.7.6 Total Time Acceptance (0.08080 + 1.97640 - 0.5) 5 2.05236 5 (0.08080 + 1.97640 + 0.5)
(1.55720) 5 2.05236 5 (2.55720) 5 illustrates the verification test Total Time Composite Leakage Rate with respect to the upper and lower limits as a function of time. Based on the above data, it was concluded that the composite leakage rate was stable, well within the limits of the test, and therefore, the Type A Test instrumentation system was considered to be verified functional throughout the Type A Test.
3.8 Reduced Data 6, ILRT Containment Air Mass Calculation Parameters, contains the reduced variables and mass calculations for the Type A Test. These values were determined from the raw data inputs.
Page 7
Iowa Electric Light & Power Duane Arnold Energy Center September, 1993 ILRT/LLRT Results 4.0 LOCAL LEAKAGE RATE TESTS (Types B and C)
The Local Leakage Rate Tests (LLRT) of containment isolation valves and other containment penetrations were conducted as required by the methods described in Duane Arnold Surveillance Test Procedures.
In accordance with 10CFR50 Appendix J, Paragraph V.B., data for the Local Leakage Rate Tests are summarized in Attachments 17 and 18 of this report.
The combined as-left leakage for all penetrations and valves subject to Type B and C tests in 1992 and 1993 were below the acceptance criteria of less than 0.60 La.
4.1 Leakage Penalties added to Type A Leakage In accordance with 10CFR50 Appendix J,Section III A.1.d, certain systems penetrating the containment boundary were not vented and drained. In order to compute the appropriate Type A Test penalty to be applied to the upper confidence limit, an analysis of each affected penetration was performed based on minimum pathway leakage through each penetration. Based on this analysis, a total pretest penalty leakage of 0.04550 %/day was assigned. The following table summarizes this analysis:
Penetration Number Leakage SCCM Description Feedwater Feedwater Core Spray Core Spray Drywell Floor Sump Drywell Cooling Inlet Drywell Cooling Inlet Drywell Cooling Outlet Drywell Cooling Outlet CRD Return Jet Pump Sample Jet Pump Sample Recirc Loop Sample Drywell Equipment Sump RBCCW Outlet RBCCW Inlet TOTAL 29 249 20 7
603 594 1847 3287 901 54 33 14 6
162 55 152 8013 SCCM (0.04550 %/day)
Page 8 X 9A X 9B X 16A X 16B X 19 X 23A X 23B X 24A X 24B X 36 X 40C X 40D X 41 X 48 X 54 X 55
Iowa Electric Light & Power Duane Arnold Energy Center September, 1993 ILRT/LLRT Results 4.2 Water Level Corrections The following water level corrections were assigned for the Type A Test:
Description ft3 Reactor Vessel
-18.744 Drywell Equipment Sump
+60.825 Drywell Floor Sump
+0.134 Torus Water Level 0.0 TOTAL 42.215 ft3 (0.05506 %/day) 4.3 Total Corrections 0.10056 %/day Page 9
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 1 UESC G100 VERSION 3.1 PAGE 1 TABLE A TEST SETUP DATA DRY BULB DEW POINT PRESSURE SENSOR SENSOR VOLUME SENSOR SENSOR VOLUME SENSOR SENSOR VOLUME NUMBER NAME FRACTION NUMBER NAME FRACTION NUMBER NAME FRACTION ME4326A ME4326B ME4326C ME4326D ME4326E ME4326F 0.110000 0.197000 0.136000 0.108000 0.224500 0.224500 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 1
2 3
PI-4368A 1.000000 PI-4368B 0.000000 0.000000 TOTAL 1.000000 0.112200 0.112300 0.112200 0.112300 0.055000 0.055000 0.065000 0.066000 0.055000 0.055000 0.040000 0.027000 0.066000 0.030000 0.037000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 0.000000 DRY BULB SYSTEM SENSITIVITY (eT)
DRY BULB SENSOR ACCURACY (ET)
= 0.01000000
= 0.100 TOTAL 1.000000 DEW POINT SYSTEM SENSITIVITY (epv) = 0.01000000 DEW POINT SENSOR ACCURACY (Ep ) = 0.500 PRESSURE SYSTEM SENSITIVITY (ep)
PRESSURE SENSOR ACCURACY (EP)
= 0.00050000
= 0.001 MAXIMUM ALLOWABLE LEAKAGE RATE, La (% per day) = 2.000 PEAK CONTAINMENT INTERNAL PRESSURE, Pac (psia) = 57.700 VERIFICATION FLOW CONVERSION FACTOR (% per day/SCFM) = 0.16200 TE4328A TE4328B TE4328C TE4328D TE4328E TE4328F TE4328G TE4328H TE4328J TE4328K TE4328L TE4328M TE4328N TE4328P TE4328Q 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 TOTAL 1.000000
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 2 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 1
TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
DATA SENSOR NUMBER SET REAL TIME 1
2 3
4 5
6 1 09/19/93:17:57:00 77.78900 77.74300 77.54300 77.65500 74.88300 74.82000 2 09/19/93:18:12:00 78.73100 78.64400 78.53800 78.70200 75.29600 74.96000 3 09/19/93:18:27:00 79.41500 79.48800 79.35100 79.50100 75.65200 75.54300 4 09/19/93:18:42:00 79.73000 79.83400 79.67700 79.82600 75.82600 75.78200 5 09/19/93:18:57:00 79.95600 80.07400 79.90500 80.02000 75.96700 75.52300 6 09/19/93:19:12:00 80.35700 80.47400 80.33700 80.37700 76.23900 75.53400 7 09/19/93:19:27:00 80.55200 80.68000 80.50000 80.59400 76.46800 75.70600 8 09/19/93:19:42:00 81.61400 81.73000 81.65900 81.69500 77.01000 76.46200 9 09/19/93:19:57:00 82.20100 82.39100 82.25500 82.33200 77.31400 76.86200 10 09/19/93:20:12:00 82.48200 82.64000 82.57000 82.62500 77.50900 76.85300 11 09/19/93:20:27:00 82.68900 82.88900 82.79800 82.88500 77.67200 77.05900 12 09/19/93:20:42:00 82.87400 83.06400 82.98200 83.01400 77.91000 77.02500 13 09/19/93:20:57:00 83.03300 83.21100 83.12900 83.16100 78.00300 77.22600 14 09/19/93:21:12:00 83.14400 83.33300 83.29700 83.28500 78.13900 77.33900 15 09/19/93:21:27:00 83.29600 83.42100 83.36200 83.38200 78.20300 77.47000 16 09/19/93:21:42:00 83.40500 83.55000 83.47100 83.49900 78.33500 77.79300 17 09/19/93:21:57:00 83.52500 83.63600 83.63200 83.56500 78.43200 77.97800 18 09/19/93:22:12:00 83.61100 83.71300 83.69700 83.67300 78.53000 78.21500 19 09/19/93:22:27:00 83.68800 83.76800 83.79500 83.75900 78.65900 78.32400 20 09/19/93:22:42:00 83.77400 83.86500 83.88100 83.85600 78.76800 78.44100 21 09/19/93:22:57:00 83.82900 83.92000 83.92600 83.93300 78.89900 78.62700 22 09/19/93:23:12:00 83.89400 83.97400 84.00100 83.96500 79.02900 78.73500 23 09/19/93:23:27:00 83.99200 84.06000 84.12100 84.10500 79.16900 79.03800 24 09/19/93:23:42:00 84.17500 84.25500 84.33800 84.29000 79.38700 79.11200 25 09/19/93:23:57:00 84.27300 84.34300 84.40200 84.38700 79.48500 79.30700 26 09/20/93:00:12:00 84.36100 84.41800 84.46800 84.45200 79.64800 79.61000 27 09/20/93:00:27:00 84.40400 84.47200 84.51100 84.52700 79.74600 79.71800 28 09/20/93:00:42:00 84.43600 84.49500 84.55300 84.56100 79.90900 79.76100 29 09/20/93:00:57:00 84.47900 84.52600 84.57600 84.58100 80.02900 79.92400 30 09/20/93:01:12:00 84.51300 84.56900 84.64200 84.63500 80.14700 80.11800 31 09/20/93:01:27:00 84.53400 84.59200 84.65100 84.65800 80.22400 80.14100 32 09/20/93:01:42:00 84.54500 84.59200 84.66200 84.66700 80.32200 80.30300 33 09/20/93:01:57:00 84.02300 84.07100 84.02400 84.04100 80.11600 80.19500 34 09/20/93:02:12:00 83.68800 83.73600 83.68600 83.71600 80.17000 80.17200 35 09/20/93:02:27:00 83.25300 83.29000 83.18800 83.21900 80.12700 79.94600 36 09/20/93:02:42:00 82.84000 82.88900 82.76400 82.80800 80.12700 79.79500 37 09/20/93:02:50:35 82.71800 82.74400 82.62000 82.66400 80.18800 79.79000 38 09/20/93:03:00:00 82.33000 82.32600 82.22300 82.26900 80.03800 79.61000 39 09/20/93:03:05:00 82.11500 82.13100 81.98600 82.06300 79.98600 79.53500 40 09/20/93:03:10:00 81.92000 81.96800 81.81100 81.90100 79.96400 79.51200
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 2
TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER REAL TIME 7
8 9
10 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 09/19/93:17:57:00 09/19/93:18:12:00 09/19/93:18:27:00 09/19/93:18:42:00 09/19/93:18:57:00 09/19/93:19:12:00 09/19/93:19:27:00 09/19/93:19:42:00 09/19/93:19:57:00 09/19/93:20:12:00 09/19/93:20:27:00 09/19/93:20:42:00 09/19/93:20:57:00 09/19/93:21:12:00 09/19/93:21:27:00 09/19/93:21:42:00 09/19/93:21:57:00 09/19/93:22:12:00 09/19/93:22:27:00 09/19/93:22:42:00 09/19/93:22:57:00 09/19/93:23:12:00 09/19/93:23:27:00 09/19/93:23:42:00 09/19/93:23:57:00 09/20/93:00:12:00 09/20/93:00:27:00 09/20/93:00:42:00 09/20/93:00:57:00 09/20/93:01:12:00 09/20/93:01:27:00 09/20/93:01:42:00 09/20/93:01:57:00 09/20/93:02:12:00 09/20/93:02:27:00 09/20/93:02:42:00 09/20/93:02:50:35 09/20/93:03:00:00 09/20/93:03:05:00 09/20/93:03:10:00 77.59800 78.27800 78.53800 78.61500 78.82100 79.03600 79.16700 79.88100 80.15000 80.34700 80.51900 80.67100 80.88300 80.99600 81.15900 81.31100 81.47100 81.61400 81.73100 81.87400 82.00300 82.14300 82.31700 82.52300 82.64100 82.78300 82.91200 83.04400 83.17300 83.31300 83.43300 83.57300 83.35600 83.39000 83.21600 83.19500 83.20000 82.97800 82.94400 82.90100 77.47000 77.91400 78.20900 78.36900 78.53300 78.84800 79.12000 79.73900 80.03100 80.40100 80.61600 80.81100 81.00400 81.22400 81.39800 81.57300 81.78900 81.98400 82.12700 82.29000 82.49400 82.64600 82.86400 83.05900 83.27700 83.42900 83.56900 83.74400 83.88400 84.04800 84.18900 84.34100 84.09100 84.11400 83.99300 83.98200 84.01200 83.85300 83.79800 83.77600 78.98700 79.35500 79.72400 79.99300 80.13500 80.40400 80.36100 81.21600 81.41000 81.70400 81.88700 82.11600 82.30600 82.57900 82.71000 82.86200 83.01300 83.26200 83.40200 83.57700 83.71700 83.90000 84.09700 84.30300 84.55100 84.73500 84.92900 85.10300 85.24400 85.41800 85.61200 85.77500 85.65500 85.60100 85.48100 85.47200 85.51100 85.40700 85.38400 85.37300 78.98600 79.25600 79.54700 79.69800 79.90300 80.09700 80.27000 80.65800 81.00500 81.30700 81.57600 81.80300 82.01500 82.24500 82.42800 82.64400 82.82900 83.02300 83.18600 83.26000 83.41100 83.61700 83.77900 84.05000 84.26400 84.44900 84.64300 84.82600 85.03100 85.20500 85.44100 85.61500 85.48400 85.52700 85.47300 85.51800 85.55700 85.44100 85.43000 85.44100 DATA SET 11 12 101.33000 101.83000 102.21000 102.39000 102.63000 102.88000 103.23000 103.80000 104.24000 104.54000 104.86000 105.08000 105.31000 105.49000 105.81000 106.02000 106.28000 106.45000 106.75000 106.93000 107.11000 107.35000 107.50000 107.76000 107.97000 108.01000 108.24000 108.46000 108.54000 108.80000 108.94000 108.96000 108.95000 109.13000 109.15000 109.22000 109.26000 109.31000 109.25000 109.37000 73.51300 73.96700 74.34400 74.50700 74.78900 75.03800 75.06900 75.67500 75.84900 75.96600 76.11800 76.30300 76.45000 76.57200 76.73500 76.84300 77.01700 77.18900 77.34000 77.52600 77.66600 77.83800 78.06600 78.24900 78.41200 78.58600 78.74900 78.92000 79.08300 79.25700 79.40900 79.56900 79.40900 79.50600 79.38600 79.38600 79.41300 79.24600 79.21200 79.21200 12
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 3
TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER REAL TIME 13 14 09/19/93:17:57:00 09/19/93:18:12:00 09/19/93:18:27:00 09/19/93:18:42:00 09/19/93:18:57:00 09/19/93:19:12:00 09/19/93:19:27:00 09/19/93:19:42:00 09/19/93:19:57:00 09/19/93:20:12:00 09/19/93:20:27:00 09/19/93:20:42:00 09/19/93:20:57:00 09/19/93:21:12:00 09/19/93:21:27:00 09/19/93:21:42:00 09/19/93:21:57:00 09/19/93:22:12:00 09/19/93:22:27:00 09/19/93:22:42:00 09/19/93:22:57:00 09/19/93:23:12:00 09/19/93:23:27:00 09/19/93:23:42:00 09/19/93:23:57:00 09/20/93:00:12:00 09/20/93:00:27:00 09/20/93:00:42:00 09/20/93:00:57:00 09/20/93:01:12:00 09/20/93:01:27:00 09/20/93:01:42:00 09/20/93:01:57:00 09/20/93:02:12:00 09/20/93:02:27:00 09/20/93:02:42:00 09/20/93:02:50:35 09/20/93:03:00:00 09/20/93:03:05:00 09/20/93:03:10:00 77.69000 78.23500 78.65800 78.91900 79.12500 79.36600 79.57300 80.22500 80.56100 80.82200 81.04000 81.23600 81.43800 81.57200 81.71500 81.88800 82.02000 82.21500 82.34500 82.47600 82.60600 82.73800 82.89000 83.11700 83.27000 83.42200 83.56300 83.68300 83.84700 83.97700 84.05400 84.19500 83.95600 83.93300 83.76100 83.69500 83.70200 83.53100 83.47600 83.44500 84.65100 84.95400 85.29900 85.55900 85.86200 86.19700 86.48800 87.04200 87.53900 88.04800 88.41400 88.86000 89.33200 89.70300 90.12600 90.49500 90.90400 91.35000 91.68500 92.08500 92.55100 92.96300 93.34300 93.65500 94.06700 94.59900 95.00000 95.42300 95.72600 96.05000 96.38800 96.69100 96.86300 97.01500 97.17800 97.37300 97.49900 97.51500 97.55800 97.64400 95.85900 96.25200 96.53400 96.82700 97.23000 97.41600 97.85100 98.54900 98.94000 99.31100 99.58100 99.99500 100.25000 100.57000 100.94000 101.25000 101.55000 101.73000 102.03000 102.24000 102.53000 102.88000 103.17000 103.41000 103.46000 103.83000 104.02000 104.19000 104.35000 104.65000 104.88000 105.10000 105.01000 105.12000 105.21000 105.33000 105.37000 105.37000 105.30000 105.31000 DATA SET 16 17 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 18 18
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 4
TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER REAL TIME 1
2 3
4 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 A
80 09/20/93:03:15:00 09/20/93:03:20:00 09/20/93:03:25:00 09/20/93:03:30:00 09/20/93:03:35:00 09/20/93:03:40:00 09/20/93:03:45:00 09/20/93:03:50:00 09/20/93:03:55:00 09/20/93:04:00:00 09/20/93:04:05:00 09/20/93:04:10:00 09/20/93:04:15:00 09/20/93:04:20:00 09/20/93:04:25:00 09/20/93:04:30:00 09/20/93:04:35:00 09/20/93:04:40:00 09/20/93:04:45:00 09/20/93:04:50:00 09/20/93:04:55:00 09/20/93:05:00:00 09/20/93:05:05:00 09/20/93:05:10:00 09/20/93:05:15:00 09/20/93:05:20:00 09/20/93:05:25:00 09/20/93:05:30:00 09/20/93:05:35:00 09/20/93:05:40:00 09/20/93:05:45:00 09/20/93:05:50:00 09/20/93:05:55:00 09/20/93:06:00:00 09/20/93:06:05:00 09/20/93:06:10:00 09/20/93:06:15:00 09/20/93:06:20:00 09/20/93:06:25:00 09/20/93:06:30:00 DATA SET 5
6 81.76600 81.64800 81.52800 81.43100 81.33400 81.26300 81.18800 81.11600 81.04100 80.98700 80.91000 80.85500 80.79200 80.72600 80.68300 80.62900 80.57500 80.52700 80.47300 80.42300 80.36800 80.32500 80.28200 80.23900 80.19400 80.15100 80.11900 80.07600 80.03300 80.01000 79.96700 79.93300 79.90200 79.87000 79.82700 79.81100 79.77900 79.73900 79.70700 79.68400 81.81600 81.68700 81.57900 81.48100 81.38400 81.30300 81.22800 81.14400 81.05800 81.00400 80.93800 80.87500 80.80900 80.75500 80.70000 80.64600 80.59200 80.54400 80.50100 80.46300 80.40900 80.35400 80.32300 80.27700 80.22500 80.19100 80.14800 80.11700 80.08300 80.04000 80.00800 79.97400 79.95400 79.91100 79.88800 79.86300 79.82900 79.80200 79.76800 79.74800 81.67100 81.56200 81.46500 81.35600 81.28100 81.20000 81.11400 81.04100 80.96700 80.90100 80.84700 80.77200 80.71800 80.65200 80.60900 80.56600 80.51200 80.46400 80.41000 80.36900 80.31700 80.27200 80.22900 80.18600 80.15400 80.11100 80.06600 80.02300 79.98000 79.95900 79.92500 79.88200 79.86000 79.82800 79.79700 79.76900 79.73800 79.69900 79.66500 79.64500 81.76100 81.64100 81.54400 81.42400 81.33800 81.25900 81.17100 81.09000 81.01300 80.95000 80.89600 80.83100 80.75400 80.70200 80.64800 80.59400 80.55100 80.50100 80.44900 80.40800 80.35400 80.30000 80.26800 80.23700 80.20300 80.14900 80.11700 80.07400 80.04300 80.00900 79.96600 79.93400 79.89200 79.86900 79.84600 79.81000 79.77900 79.74900 79.71800 79.68600 79.98600 79.95200 79.96400 79.95200 79.92000 79.90500 79.89300 79.86600 79.87700 79.87700 79.84300 79.85500 79.86600 79.85500 79.82300 79.84300 79.84300 79.86100 79.83900 79.82300 79.84300 79.84300 79.82300 79.82300 79.82300 79.83200 79.84300 79.82300 79.85500 79.87700 79.86600 79.88600 79.88600 79.89800 79.92000 79.92700 79.93600 79.96400 79.96400 79.97500 79.49200 79.48100 79.48100 79.46900 79.45800 79.45400 79.46500 79.44900 79.45800 79.44900 79.44900 79.43800 79.43800 79.43800 79.42600 79.42600 79.43800 79.44500 79.43300 79.42600 79.53500 79.49200 79.42600 79.46900 79.48100 79.42600 79.46900 79.55500 79.50100 79.49200 79.46900 79.57800 79.55500 79.45800 79.45800 79.43300 79.47600 79.39500 79.41500 79.39500
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 5
TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER REAL TIME 09/20/93:03:15:00 09/20/93:03:20:00 09/20/93:03:25:00 09/20/93:03:30:00 09/20/93:03:35:00 09/20/93:03:40:00 09/20/93:03:45:00 09/20/93:03:50:00 09/20/93:03:55:00 09/20/93:04:00:00 09/20/93:04:05:00 09/20/93:04:10:00 09/20/93:04:15:00 09/20/93:04:20:00 09/20/93:04:25:00 09/20/93:04:30:00 09/20/93:04:35:00 09/20/93:04:40:00 09/20/93:04:45:00 09/20/93:04:50:00 09/20/93:04:55:00 09/20/93:05:00:00 09/20/93:05:05:00 09/20/93:05:10:00 09/20/93:05:15:00 09/20/93:05:20:00 09/20/93:05:25:00 09/20/93:05:30:00 09/20/93:05:35:00 09/20/93:05:40:00 09/20/93:05:45:00 09/20/93:05:50:00 09/20/93:05:55:00 09/20/93:06:00:00 09/20/93:06:05:00 09/20/93:06:10:00 09/20/93:06:15:00 09/20/93:06:20:00 09/20/93:06:25:00 09/20/93:06:30:00 7
8 82.88100 82.88100 82.88100 82.88100 82.88100 82.87600 82.88700 82.88100 82.89200 82.89200 82.88100 82.88100 82.89200 82.89200 82.91200 82.91200 82.92400 82.93000 82.94200 82.93500 82.94400 82.94400 82.95500 82.97800 82.98900 82.98900 83.01000 83.02100 83.03200 83.04400 83.05300 83.06400 83.06400 83.09800 83.09800 83.11400 83.13600 83.14100 83.15000 83.16100 83.75500 83.74400 83.73200 83.73200 83.73200 83.75100 83.73900 83.73200 83.73200 83.74400 83.77600 83.77600 83.76700 83.76700 83.77600 83.78700 83.79800 83.81600 83.81600 83.81000 83.83000 83.84100 83.86400 83.87300 83.88400 83.90700 83.91900 83.92800 83.95000 83.97300 83.99300 84.01600 84.03700 84.03700 84.05900 84.08600 84.09800 84.10200 84.12500 84.14500 9
85.38400 85.39500 85.40700 85.40700 85.41800 85.43400 85.45600 85.47200 85.50400 85.50400 85.51500 85.54700 85.59000 85.59000 85.62400 85.63300 85.66700 85.69400 85.70500 85.69800 85.76400 85.76400 85.79600 85.83000 85.85000 85.88200 85.91600 85.93600 85.97000 86.00200 86.02400 86.04500 86.07900 86.11000 86.11000 86.13700 86.17100 86.19600 86.23000 86.25100 DATA SET 10 85.44100 85.45300 85.47300 85.47300 85.50700 85.52300 85.53400 85.55000 85.56100 85.58100 85.59300 85.61500 85.63500 85.64700 85.65800 85.70100 85.70100 85.72800 85.75100 85.76600 85.77500 85.79800 85.80900 85.85200 85.88400 85.88400 85.92600 85.94900 85.98100 86.00300 86.02600 86.04600 86.07800 86.12300 86.12300 86.16100 86.18100 86.19700 86.22000 86.24000 11 109.42000 109.42000 109.47000 109.48000 109.60000 109.63000 109.64000 109.62000 109.69000 109.84000 109.83000 109.90000 109.91000 109.86000 109.93000 109.94000 110.08000 110.00000 110.05000 110.04000 110.07000 110.07000 110.13000 110.16000 110.29000 110.36000 110.44000 110.55000 110.59000 110.67000 110.86000 110.80000 110.94000 110.96000 111.11000 111.19000 111.22000 111.28000 111.27000 111.33000 12 79.22300 79.21200 79.20300 79.20300 79.22300 79.21000 79.18700 79.20300 79.22300 79.24600 79.24600 79.23500 79.24600 79.25700 79.26600 79.27800 79.27800 79.28500 79.29600 79.31200 79.31200 79.31200 79.32100 79.34300 79.35500 79.35500 79.36400 79.37500 79.39800 79.39800 79.39800 79.41800 79.41800 79.44100 79.45200 79.44700 79.50200 79.48400 79.50600 79.51500
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 6
TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER REAL TIME 09/20/93:03:15:00 09/20/93:03:20:00 09/20/93:03:25:00 09/20/93:03:30:00 09/20/93:03:35:00 09/20/93:03:40:00 09/20/93:03:45:00 09/20/93:03:50:00 09/20/93:03:55:00 09/20/93:04:00:00 09/20/93:04:05:00 09/20/93:04:10:00 09/20/93:04:15:00 09/20/93:04:20:00 09/20/93:04:25:00 09/20/93:04:30:00 09/20/93:04:35:00 09/20/93:04:40:00 09/20/93:04:45:00 09/20/93:04:50:00 09/20/93:04:55:00 09/20/93:05:00:00 09/20/93:05:05:00 09/20/93:05:10:00 09/20/93:05:15:00 09/20/93:05:20:00 09/20/93:05:25:00 09/20/93:05:30:00 09/20/93:05:35:00 09/20/93:05:40:00 09/20/93:05:45:00 09/20/93:05:50:00 09/20/93:05:55:00 09/20/93:06:00:00 09/20/93:06:05:00 09/20/93:06:10:00 09/20/93:06:15:00 09/20/93:06:20:00 09/20/93:06:25:00 09/20/93:06:30:00 13 83.43300 83.41100 83.40100 83.39000 83.39000 83.39700 83.38600 83.39000 83.37900 83.39000 83.40100 83.40100 83.41100 83.41100 83.41100 83.41100 83.42200 83.42900 83.44000 83.43300 83.44500 83.46500 83.47600 83.47600 83.49900 83.49900 83.52000 83.53100 83.55400 83.57400 83.57400 83.59700 83.60800 83.60800 83.62900 83.65800 83.65800 83.67200 83.68300 83.70600 14 97.63300 97.71000 97.75300 97.82800 97.87300 97.98600 98.02000 98.05600 98.09900 98.14200 98.19700 98.27400 98.30600 98.31700 98.39200 98.45700 98.46900 98.53000 98.57300 98.62000 98.65200 98.64100 98.71800 98.74900 98.83800 98.91300 98.97800 99.04400 99.15000 99.20500 99.29300 99.31400 99.43400 99.46500 99.54200 99.62400 99.69000 99.73700 99.83400 99.82300 15 105.42000 105.43000 105.46000 105.41000 105.57000 105.57000 105.65000 105.68000 105.69000 105.69000 105.77000 105.90000 105.88000 105.91000 105.91000 106.01000 106.09000 106.10000 106.14000 106.20000 106.14000 106.25000 106.26000 106.28000 106.35000 106.45000 106.53000 106.60000 106.64000 106.69000 106.82000 106.89000 106.95000 107.04000 107.04000 107.13000 107.23000 107.26000 107.34000 107.37000 DATA SET 16 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 17 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 18 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 7
TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER 3
4 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 AM 120 09/20/93:06:35:00 09/20/93:06:40:00 09/20/93:06:45:00 09/20/93:06:50:00 09/20/93:06:55:00 09/20/93:07:00:00 09/20/93:07:05:00 09/20/93:07:15:00 09/20/93:07:30:00 09/20/93:07:45:00 09/20/93:08:00:00 09/20/93:08:15:00 09/20/93:08:30:00 09/20/93:08:45:00 09/20/93:09:00:00 09/20/93:09:15:00 09/20/93:09:30:00 09/20/93:09:45:00 09/20/93:10:00:00 09/20/93:10:15:00 09/20/93:10:30:00 09/20/93:10:45:00 09/20/93:11:00:00 09/20/93:11:15:00 09/20/93:11:30:00 09/20/93:11:45:00 09/20/93:12:00:00 09/20/93:12:15:00 09/20/93:12:30:00 09/20/93:12:45:00 09/20/93:13:00:00 09/20/93:13:15:00 09/20/93:13:30:00 09/20/93:13:45:00 09/20/93:14:00:00 09/20/93:14:15:00 09/20/93:14:30:00 09/20/93:14:45:00 09/20/93:15:00:00 09/20/93:15:15:00 DATA SET REAL TTMR 1
2 79.66400 79.63000 79.61000 79.58200 79.55100 79.53300 79.50100 79.44600 79.40300 79.32600 79.28300 79.22900 79.17500 79.13200 79.07700 79.03400 79.01400 78.96900 78.94800 78.91600 78.88200 78.85100 78.81700 78.80800 78.77400 78.75300 78.73800 78.71000 78.68300 78.68300 78.66100 78.64500 78.62200 78.61100 78.59000 78.57900 78.56800 78.55900 78.53600 78.53600 79.72500 79.69300 79.68200 79.64600 79.63500 79.59600 79.56400 79.51900 79.45600 79.40200 79.34700 79.29300 79.23900 79.18400 79.14100 79.08700 79.05500 79.01000 78.95600 78.93500 78.90400 78.87000 78.83800 78.80400 78.77300 78.75200 78.73600 78.70700 78.68200 78.67100 78.66000 78.64400 78.62100 78.59800 78.59800 78.57800 78.56700 78.54600 78.54600 78.53500 79.62200 79.59100 79.55700 79.54300 79.53200 79.49300 79.47100 79.42800 79.36200 79.29900 79.24400 79.19000 79.13600 79.09300 79.03800 78.99500 78.94100 78.90700 78.87500 78.84100 78.81000 78.78900 78.74400 78.72400 78.70100 78.68100 78.66500 78.63800 78.59900 78.59900 78.57900 78.56100 78.53800 78.52900 78.50700 78.49500 78.48600 78.47500 78.46400 78.45200 79.66400 79.63200 79.62100 79.58500 79.56200 79.53500 79.50100 79.45800 79.39300 79.33000 79.27500 79.22100 79.17800 79.12400 79.08100 79.03600 78.99300 78.95100 78.92800 78.88500 78.86500 78.84200 78.81100 78.78800 78.75600 78.74500 78.72000 78.69100 78.67500 78.66600 78.65500 78.62600 78.60500 78.59400 78.57400 78.55100 78.54000 78.52800 78.51900 78.50800 79.99500 79.97500 80.00700 80.02500 80.02500 80.02900 80.03800 80.05000 80.07200 80.11600 80.15900 80.20200 80.23600 80.25600 80.29900 80.32200 80.35400 80.39700 80.43100 80.45100 80.49700 80.52900 80.56000 80.59400 80.61500 80.65800 80.69900 80.72400 80.76200 80.79600 80.81700 80.85300 80.88700 80.91900 80.94200 80.98500 81.00500 81.06000 81.08200 81.10500 79.48100 79.44900 79.45800 79.45400 79.43300 79.45800 79.43800 79.48100 79.53500 79.57800 79.64300 79.68600 79.71800 79.75200 79.78400 79.80600 79.83800 79.85800 79.89200 79.92400 79.94600 79.97800 80.01000 80.04300 80.07500 80.10900 80.15900 80.18400 80.21300 80.25600 80.28800 80.31500 80.34600 80.38900 80.41200 80.44400 80.47500 80.50900 80.52900 80.57200 SET REAL TIME i
2 3
4 5
5 6
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 8
TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER REAL TIME 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 7
09/20/93:06:35:00 09/20/93:06:40:00 09/20/93:06:45:00 09/20/93:06:50:00 09/20/93:06:55:00 09/20/93:07:00:00 09/20/93:07:05:00 09/20/93:07:15:00 09/20/93:07:30:00 09/20/93:07:45:00 09/20/93:08:00:00 09/20/93:08:15:00 09/20/93:08:30:00 09/20/93:08:45:00 09/20/93:09:00:00 09/20/93:09:15:00 09/20/93:09:30:00 09/20/93:09:45:00 09/20/93:10:00:00 09/20/93:10:15:00 09/20/93:10:30:00 09/20/93:10:45:00 09/20/93:11:00:00 09/20/93:11:15:00 09/20/93:11:30:00 09/20/93:11:45:00 09/20/93:12:00:00 09/20/93:12:15:00 09/20/93:12:30:00 09/20/93:12:45:00 09/20/93:13:00:00 09/20/93:13:15:00 09/20/93:13:30:00 09/20/93:13:45:00 09/20/93:14:00:00 09/20/93:14:15:00 09/20/93:14:30:00 09/20/93:14:45:00 09/20/93:15:00:00 09/20/93:15:15:00 8
83.18400 83.18400 83.20400 83.22200 83.23400 83.23800 83.24900 83.27000 83.31300 83.36700 83.40100 83.44400 83.47600 83.51900 83.56200 83.59600 83.65000 83.69300 83.71300 83.76800 83.81100 83.84500 83.88800 83.93100 83.97400 84.01700 84.05700 84.08200 84.13200 84.17500 84.21800 84.24500 84.27700 84.32000 84.36500 84.39700 84.44000 84.47100 84.50500 84.53700 9
84.15700 84.16800 84.17700 84.20700 84.22900 84.22300 84.23200 84.26600 84.32000 84.34100 84.40600 84.43800 84.47200 84.52700 84.57000 84.61300 84.65600 84.69900 84.74200 84.77600 84.81900 84.87400 84.89400 84.94900 84.99200 85.03700 85.09600 85.13500 85.15100 85.22800 85.27100 85.30700 85.35000 85.38400 85.41600 85.45900 85.51400 85.55700 85.57900 85.63400 DATA SET 86.26200 86.29400 86.31600 86.34300 86.37700 86.40200 86.40200 86.44500 86.52200 86.58800 86.65100 86.72800 86.79400 86.85700 86.92300 86.98800 87.05200 87.09700 87.16000 87.22600 87.29100 87.34600 87.40900 87.46300 87.51800 87.58300 87.65600 87.70300 87.76400 87.82800 87.90500 87.94100 87.99500 88.06100 88.12400 88.19000 88.23300 88.29900 88.35300 88.40700 10 86.26300 86.28300 86.30600 86.33300 86.34400 86.37100 86.40300 86.45700 86.52200 86.57600 86.64000 86.72800 86.80200 86.85600 86.93300 86.98700 87.05000 87.11600 87.19200 87.25600 87.32100 87.37500 87.44100 87.49500 87.55800 87.60100 87.67300 87.73200 87.79300 87.86700 87.90100 87.96900 88.02300 88.07700 88.15400 88.20800 88.25100 88.31400 88.38000 88.44500 11 111.43000 111.47000 111.54000 111.55000 111.63000 111.68000 111.72000 111.81000 112.04000 112.11000 112.22000 112.35000 112.44000 112.66000 112.73000 112.89000 113.01000 113.12000 113.10000 113.17000 113.38000 113.50000 113.57000 113.51000 113.73000 113.75000 113.87000 113.89000 114.02000 114.08000 114.10000 114.23000 114.24000 114.42000 114.47000 114.58000 114.70000 114.70000 114.73000 114.81000 19 79.52600 79.51500 79.52600 79.54500 79.56500 79.59200 79.59200 79.61500 79.62400 79.68900 79.72100 79.75500 79.78700 79.80900 79.84100 79.87200 79.89500 79.91800 79.96100 79.98100 80.01500 80.04700 80.05800 80.10100 80.12300 80.13200 80.18200 80.24100 80.27000 80.32500 80.34500 80.39300 80.43600 80.46900 80.50100 80.52400 80.56700 80.57800 80.59800 80.64100 12
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 9
TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER REAL TIME 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 13 09/20/93:06:35:00 09/20/93:06:40:00 09/20/93:06:45:00 09/20/93:06:50:00 09/20/93:06:55:00 09/20/93:07:00:00 09/20/93:07:05:00 09/20/93:07:15:00 09/20/93:07:30:00 09/20/93:07:45:00 09/20/93:08:00:00 09/20/93:08:15:00 09/20/93:08:30:00 09/20/93:08:45:00 09/20/93:09:00:00 09/20/93:09:15:00 09/20/93:09:30:00 09/20/93:09:45:00 09/20/93:10:00:00 09/20/93:10:15:00 09/20/93:10:30:00 09/20/93:10:45:00 09/20/93:11:00:00 09/20/93:11:15:00 09/20/93:11:30:00 09/20/93:11:45:00 09/20/93:12:00:00 09/20/93:12:15:00 09/20/93:12:30:00 09/20/93:12:45:00 09/20/93:13:00:00 09/20/93:13:15:00 09/20/93:13:30:00 09/20/93:13:45:00 09/20/93:14:00:00 09/20/93:14:15:00 09/20/93:14:30:00 09/20/93:14:45:00 09/20/93:15:00:00 09/20/93:15:15:00 14 83.72700 83.73800 83.73800 83.75600 83.77600 83.78100 83.79200 83.82400 83.87900 83.91300 83.96500 84.01100 84.05400 84.08600 84.14000 84.17200 84.21800 84.24900 84.29300 84.34700 84.37900 84.43300 84.46800 84.51100 84.55400 84.59700 84.64700 84.67400 84.71300 84.75600 84.79900 84.83600 84.88100 84.92400 84.95600 85.00000 85.04300 85.08800 85.12000 85.17500 99.90000 99.97500 100.02000 100.06000 100.10000 100.25000 100.24000 100.36000 100.50000 100.65000 100.85000 100.94000 101.13000 101.22000 101.36000 101.50000 101.62000 101.83000 101.89000 102.01000 102.12000 102.22000 102.33000 102.42000 102.59000 102.68000 102.79000 102.89000 103.01000 103.10000 103.16000 103.28000 103.37000 103.48000 103.60000 103.68000 103.76000 103.85000 103.99000 104.09000 DATA SET 16 17 107.45000 107.45000 107.50000 107.53000 107.64000 107.68000 107.72000 107.84000 107.93000 108.15000 108.23000 108.39000 108.48000 108.68000 108.80000 108.91000 109.02000 109.07000 109.18000 109.27000 109.47000 109.53000 109.60000 109.67000 109.76000 109.86000 109.92000 110.07000 110.10000 110.25000 110.30000 110.37000 110.42000 110.55000 110.58000 110.66000 110.77000 110.77000 110.85000 110.94000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000
.0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 10 TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
DATA sw aa TTM1!
SENSOR NUMBER 1
3 4A 121 09/20/93:15:30:00 78.51300 122 09/20/93:15:45:00 78.52000 123 09/20/93:16:00:00 78.49300 124 09/20/93:16:15:00 78.49300 125 09/20/93:16:30:00 78.45900 126 09/20/93:16:45:00 78.45000 127 09/20/93:17:00:00 78.43900 128 09/20/93:17:15:00 78.42700 129 09/20/93:17:30:00 78.41600 130 09/20/93:17:45:00 78.40700 131 09/20/93:18:00:00 78.39600 132 09/20/93:18:15:00 78.39600 133 09/20/93:18:30:00 78.37300 134 09/20/93:18:45:00 78.38000 135 09/20/93:19:00:00 78.36200 136 09/20/93:19:15:00 78.35300 137 09/20/93:19:30:00 78.34100 138 09/20/93:19:45:00 78.34100 139 09/20/93:20:00:00 78.33000 140 09/20/93:20:15:00 78.32500 141 09/20/93:20:30:00 78.31900 142 09/20/93:20:45:00 78.31400 143 09/20/93:21:00:00 78.30500 144 09/20/93:21:15:00 78.29800 145 09/20/93:21:30:00 78.27600 78.51200 78.43200 78.50800 78.42700 78.49200 78.40900 78.49200 78.39800 78.45800 78.37800 78.44700 78.36600 78.42600 78.34400 78.41500 78.33200 78.40400 78.32300 78.39500 78.32300 78.38300 78.30100 78.37200 78.28900 78.36100 78.28000 78.35600 78.27600 78.34100 78.25800 78.32900 78.25800 78.32900 78.24600 78.30700 78.24600 78.30700 78.23500 78.30200 78.23000 78.29500 78.21500 78.29300 78.21000 78.28200 78.19900 78.27500 78.19200 78.27500 78.18100 78.48600 81.13700 80.59500 78.49200 81.19800 80.63300 78.47400 81.21200 80.66000 78.45400 81.23400 80.69200 78.44300 81.25700 80.71500 78.42000 81.30000 80.73500 78.41100 81.32100 80.76900 78.40000 81.36400 80.80100 78.38900 81.40900 80.82300 78.37700 81.43000 80.85500 78.36800 81.46400 80.87500 78.35700 81.48400 80.90900 78.34600 81.51600 80.94100 78.34100 81.55700 80.97900 78.33400 81.58200 80.99500 78.32300 81.60400 81.02700 78.31400 81.64700 81.06100 78.31400 81.67900 81.08100 78.30300 81.70200 81.10400 78.29800 81.74100 81.14200 78.29200 81.75600 81.16900 78.28700 81.81800 81.19600 78.27600 81.82700 81.23000 78.26000 81.86500 81.25500 78.26000 81.89700 81.27800 SET REAL TIME 1
2 3
4 rl rl 2
5 6
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 11 TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER REWAL. TIME 7
A 9
TO0 09/20/93:15:30:00 09/20/93:15:45:00 09/20/93:16:00:00 09/20/93:16:15:00 09/20/93:16:30:00 09/20/93:16:45:00 09/20/93:17:00:00 09/20/93:17:15:00 09/20/93:17:30:00 09/20/93:17:45:00 09/20/93:18:00:00 09/20/93:18:15:00 09/20/93:18:30:00 09/20/93:18:45:00 09/20/93:19:00:00 09/20/93:19:15:00 09/20/93:19:30:00 09/20/93:19:45:00 09/20/93:20:00:00 09/20/93:20:15:00 09/20/93:20:30:00 09/20/93:20:45:00 09/20/93:21:00:00 09/20/93:21:15:00 09/20/93:21:30:00 84.58000 84.62100 84.66800 84.70000 84.72300 84.75400 84.78600 84.82000 84.86300 84.89500 84.92900 84.98100 85.00300 85.03300 85.06900 85.08900 85.13200 85.16600 85.19800 85.22700 85.26400 85.29100 85.33600 85.36100 85.41500 85.67700 85.72700 85.77500 85.78600 85.84000 85.87200 85.90600 85.94900 85.98100 86.02400 86.05800 86.10100 86.15600 86.19500 86.23100 86.27400 86.30800 86.34000 86.39400 86.43300 86.46000 86.52100 86.55300 86.58900 86.62300 88.46200 88.52300 88.57900 88.63400 88.68800 88.74200 88.79700 88.84000 88.91700 88.96000 89.01400 89.06800 89.13400 89.19300 89.22000 89.29500 89.34000 89.40300 89.44600 89.50800 89.55500 89.61600 89.65900 89.70700 89.76100 88.48800 88.56000 88.61700 88.66200 88.72500 88.77900 88.83300 88.88700 88.94200 88.99600 89.06100 89.11500 89.17000 89.24000 89.28700 89.35300 89.39500 89.45000 89.50400 89.57600 89.61200 89.67300 89.73600 89.77500 89.82900 114.85000 114.90000 114.99000 115.09000 115.15000 115.24000 115.36000 115.33000 115.47000 115.47000 115.56000 115.61000 115.70000 115.74000 115.84000 115.84000 115.94000 116.03000 116.03000 116.20000 116.17000 116.22000 116.29000 116.40000 116.42000 DATA SE.T 11 12 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 80.69600 80.71400 80.75000 80.77300 80.76100 80.80400 80.83600 80.84700 80.87000 80.89000 80.93500 80.94400 80.99900 81.03900 81.07600 81.10700 81.14100 81.15000 81.18400 81.21100 81.22700 81.29700 81.28800 81.33600 81.36700 SET REAL TIME 7
8 9
io
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 2 UESC G100 VERSION 3.1 PAGE 12 TABLE B DRY BULB TEMPERATURE SENSOR READINGS (DEG F)
SENSOR NUMBER 15 16 09/20/93:15:30:00 09/20/93:15:45:00 09/20/93:16:00:00 09/20/93:16:15:00 09/20/93:16:30:00 09/20/93:16:45:00 09/20/93:17:00:00 09/20/93:17:15:00 09/20/93:17:30:00 09/20/93:17:45:00 09/20/93:18:00:00 09/20/93:18:15:00 09/20/93:18:30:00 09/20/93:18:45:00 09/20/93:19:00:00 09/20/93:19:15:00 09/20/93:19:30:00 09/20/93:19:45:00 09/20/93:20:00:00 09/20/93:20:15:00 09/20/93:20:30:00 09/20/93:20:45:00 09/20/93:21:00:00 09/20/93:21:15:00 09/20/93:21:30:00 85.17500 85.23600 85.27200 85.29500 85.34700 85.37000 85.40200 85.44700 85.47900 85.52200 85.56600 85.60000 85.62000 85.67000 85.69800 85.74100 85.77300 85.80400 85.83800 85.88900 85.91400 85.96400 85.98600 86.01100 86.05700 104.15000 104.20000 104.35000 104.36000 104.46000 104.61000 104.61000 104.72000 104.85000 104.96000 104.99000 105.09000 105.13000 105.21000 105.39000 105.46000 105.53000 105.54000 105.61000 105.77000 105.81000 105.88000 105.92000 106.00000 106.21000 111.03000 111.09000 111.21000 111.22000 111.26000 111.42000 111.42000 111.51000 111.62000 111.64000 111.75000 111.78000 111.87000 111.90000 112.02000 112.06000 112.06000 112.19000 112.26000 112.28000 112.29000 112.46000 112.48000 112.49000 112.62000 DATA SET EEALT.TMRE 14 17 18 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 SET REAL TIME 14 1 -5 16 17 iR
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 3 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 1
TABLE C DEW POINT TEMPERATURE SENSOR READINGS (DEG F)
DATA SENSOR NUMBER SET REAL TIME 1
2 3
4 5
6 1 09/19/93:17:57:00 71.69300 69.68700 71.61800 71.76700 77.78900 77.54300 2 09/19/93:18:12:00 72.05300 70.54700 70.31500 71.98500 78.73100 78.53800 3 09/19/93:18:27:00 71.99900 70.58800 67.91500 72.27100 79.41500 79.35100 4 09/19/93:18:42:00 71.82200 70.24700 66.84000 72.06700 79.73000 79.67700 5 09/19/93:18:57:00 71.60400 69.86500 68.53100 71.65200 79.95600 79.90500 6 09/19/93:19:12:00 71.43400 69.72100 67.29900 71.45400 80.35700 80.33700 7 09/19/93:19:27:00 71.17500 69.36600 67.23700 71.26300 80.55200 80.50000 8 09/19/93:19:42:00 71.27000 69.30400 64.96300 71.69300 81.61400 81.65900 9 09/19/93:19:57:00 71.03200 69.10600 64.42900 71.39300 82.20100 82.25500 10 09/19/93:20:12:00 70.65000 68.70900 63.39600 70.91600 82.48200 82.57000 11 09/19/93:20:27:00 70.47900 68.50400 64.46300 70.59500 82.68900 82.79800 12 09/19/93:20:42:00 70.38400 68.26400 64.29200 70.40400 82.87400 82.98200 13 09/19/93:20:57:00 70.19300 68.14100 63.79300 70.34300 83.03300 83.12900 14 09/19/93:21:12:00 69.98100 67.99100 64.49100 70.22000 83.14400 83.29700 15 09/19/93:21:27:00 70.03500 67.98400 64.61400 70.02200 83.29600 83.36200 16 09/19/93:21:42:00 70.09000 67.84000 63.51900 70.00100 83.40500 83.47100 17 09/19/93:21:57:00 69.93300 67.85400 63.23900 70.18600 83.52500 83.63200 18 09/19/93:22:12:00 70.10400 67.79900 62.64400 70.08300 83.61100 83.69700 19 09/19/93:22:27:00 70.00800 67.99100 63.24600 69.87800 83.68800 83.79500 20 09/19/93:22:42:00 70.12400 68.10000 63.55300 70.21300 83.77400 83.88100 21 09/19/93:22:57:00 70.13100 68.27100 62.27300 70.01500 83.82900 83.92600 22 09/19/93:23:12:00 70.51300 68.51800 63.55300 70.12400 83.89400 84.00100 23 09/19/93:23:27:00 70.21300 68.56500 64.53900 70.37300 83.99200 84.12100 24 09/19/93:23:42:00 70.72500 68.64800 64.27200 70.66300 84.17500 84.33800 25 09/19/93:23:57:00 70.73900 68.97600 64.56600 71.19500 84.27300 84.40200 26 09/20/93:00:12:00 70.95700 69.20900 64.81900 72.14800 84.36100 84.46800 27 09/20/93:00:27:00 71.19500 69.66700 64.89500 72.21600 84.40400 84.51100 28 09/20/93:00:42:00 71.49500 69.46800 64.53900 72.42700 84.43600 84.55300 29 09/20/93:00:57:00 71.71300 69.88500 65.98400 72.85500 84.47900 84.57600 30 09/20/93:01:12:00 72.22300 69.88500 65.86700 73.00400 84.51300 84.64200 31 09/20/93:01:27:00 72.06700 70.32900 65.61400 72.64500 84.53400 84.65100 32 09/20/93:01:42:00 72.38000 70.54700 66.12100 73.32300 84.54500 84.66200 33 09/20/93:01:57:00 72.17600 70.27400 67.06600 72.91600 84.02300 84.02400 34 09/20/93:02:12:00 72.09400 70.44500 67.72400 72.79400 83.68800 83.68600 35 09/20/93:02:27:00 72.00600 70.21300 67.94900 72.50200 83.25300 83.18800 36 09/20/93:02:42:00 71.82200 70.26100 69.72100 72.69200 82.84000 82.76400 37 09/20/93:02:50:35 72.01900 70.15800 69.79000 73.01800 82.71800 82.62000 38 09/20/93:03:00:00 71.91700 69.90600 71.77400 72.22300 82.33000 82.22300 39 09/20/93:03:05:00 71.91000 70.22300 71.30400 72.93000 82.11500 81.98600 40 09/20/93:03:10:00 71.91000 70.34300 71.20900 72.76000 81.92000 81.81100
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 3 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 2 TABLE C DEW POINT TEMPERATURE SENSOR READINGS (DEG F)
DATA SENSOR NUMBER SET REAL TIME 1
2 3
4 5
6 41 09/20/93:03:15:00 71.85600 69.85800 71.89700 72.66500 81.76600 81.67100 42 09/20/93:03:20:00 71.85600 70.19300 72.19600 72.66500 81.64800 81.56200 43 09/20/93:03:25:00 71.83600 70.03500 72.17600 72.27800 81.52800 81.46500 44 09/20/93:03:30:00 71.78800 70.20600 72.57700 72.79400 81.43100 81.35600 45 09/20/93:03:35:00 71.98500 69.79600 72.68500 72.66500 81.33400 81.28100 46 09/20/93:03:40:00 71.99900 69.75500 72.81400 72.95000 81.26300 81.20000 47 09/20/93:03:45:00 71.93100 70.08300 72.93600 72.76700 81.18800 81.11400 48 09/20/93:03:50:00 72.14200 69.94000 72.70600 72.07400 81.11600 81.04100 49 09/20/93:03:55:00 72.14200 70.09000 72.77400 72.90300 81.04100 80.96700 50 09/20/93:04:00:00 72.23700 70.04900 72.59700 72.80800 80.98700 80.90100 51 09/20/93:04:05:00 72.21600 70.18600 72.83500 73.01100 80.91000 80.84700 52 09/20/93:04:10:00 72.23700 70.26100 72.74600 72.43400 80.85500 80.77200 53 09/20/93:04:15:00 72.50900 70.45900 72.91600 73.18700 80.79200 80.71800 54 09/20/93:04:20:00 72.36600 70.20600 72.95000 72.54900 80.72600 80.65200 55 09/20/93:04:25:00 72.46100 70.54700 72.79400 73.07200 80.68300 80.60900 56 09/20/93:04:30:00 72.50200 70.49300 72.73300 72.84800 80.62900 80.56600 57 09/20/93:04:35:00 72.61700 70.53400 72.86900 73.25500 80.57500 80.51200 58 09/20/93:04:40:00 72.70600 70.54700 72.80800 72.98400 80.52700 80.46400 59 09/20/93:04:45:00 72.70600 70.54700 72.80800 72.98400 80.47300 80.41000 60 09/20/93:04:50:00 72.67200 70.36300 72.82800 72.61100 80.42300 80.36900 61 09/20/93:04:55:00 72.71900 70.50700 72.71900 73.54000 80.36800 80.31700 62 09/20/93:05:00:00 72.74600 70.30200 72.90900 73.24200 80.32500 80.27200 63 09/20/93:05:05:00 72.89600 70.90200 72.95000 73.62800 80.28200 80.22900 64 09/20/93:05:10:00 72.88200 71.10000 72.23500 73.35700 80.23900 80.18600 65 09/20/93:05:15:00 72.91600 70.79300 72.90300 73.09900 80.19400 80.15400 66 09/20/93:05:20:00 72.86900 70.34300 72.96400 73.23500 80.15100 80.11100 67 09/20/93:05:25:00 72.99100 70.63600 72.76700 73.39800 80.11900 80.06600 68 09/20/93:05:30:00 73.00400 70.96400 73.15400 73.81100 80.07600 80.02300 69 09/20/93:05:35:00 72.98400 70.73900 72.98400 73.54000 80.03300 79.98000 70 09/20/93:05:40:00 73.01800 70.79300 73.16000 73.77000 80.01000 79.95900 71 09/20/93:05:45:00 73.14000 71.10700 73.16000 73.77000 79.96700 79.92500 72 09/20/93:05:50:00 73.09300 71.03200 73.28200 73.48600 79.93300 79.88200 73 09/20/93:05:55:00 73.14700 71.25000 73.35000 73.30000 79.90200 79.86000 74 09/20/93:06:00:00 73.12600 71.25000 73.38400 73.85800 79.87000 79.82800 75 09/20/93:06:05:00 73.24200 71.01100 73.17400 73.84500 79.82700 79.79700 76 09/20/93:06:10:00 73.22800 71.02500 73.23200 73.98000 79.81100 79.76900 77 09/20/93:06:15:00 73.22800 71.17500 73.35700 73.91900 79.77900 79.73800 78 09/20/93:06:20:00 73.30300 71.06600 73.24800 73.91200 79.73900 79.69900 79 09/20/93:06:25:00 73.38400 71.11400 73.36400 74.33800 79.70700 79.66500 80 09/20/93:06:30:00 73.44500 71.35200 73.47200 74.09500 79.68400 79.64500
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 3 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 3
TABLE C DEW POINT TEMPERATURE SENSOR READINGS (DEG F)
DATA SENSOR NUMBER SET REAL TIME 1
2 3
4 5
6 81 09/20/93:06:35:00 73.43100 71.40700 73.52600 74.07400 79.66400 79.62200 82 09/20/93:06:40:00 73.45200 71.28400 73.52600 74.09500 79.63000 79.59100 83 09/20/93:06:45:00 73.45200 71.28400 73.52600 74.09500 79.61000 79.55700 84 09/20/93:06:50:00 73.46500 71.44100 73.56700 74.02000 79.58200 79.54300 85 09/20/93:06:55:00 73.58700 71.22900 73.48600 73.54000 79.55100 79.53200 86 09/20/93:07:00:00 73.55300 71.48200 73.58100 73.98700 79.53300 79.49300 87 09/20/93:07:05:00 73.59400 71.42700 72.56700 74.46000 79.50100 79.47100 88 09/20/93:07:15:00 73.72300 71.50900 73.68900 74.14200 79.44600 79.42800 89 09/20/93:07:30:00 73.82400 71.66500 73.96600 74.01400 79.40300 79.36200 90 09/20/93:07:45:00 73.84500 71.65900 73.87200 74.34500 79.32600 79.29900 91 09/20/93:08:00:00 74.02000 71.80200 74.25000 74.66900 79.28300 79.24400 92 09/20/93:08:15:00 74.06100 72.14800 74.29100 74.22300 79.22900 79.19000 93 09/20/93:08:30:00 74.23000 72.25000 74.31100 74.80400 79.17500 79.13600 94 09/20/93:08:45:00 74.28400 72.31800 74.58100 74.65500 79.13200 79.09300 95 09/20/93:09:00:00 74.34500 72.46800 74.49300 74.52000 79.07700 79.03800 96 09/20/93:09:15:00 74.41200 72.38000 74.59500 75.33600 79.03400 78.99500 97 09/20/93:09:30:00 74.60100 72.52900 74.55400 75.34300 79.01400 78.94100 98 09/20/93:09:45:00 74.59500 72.37300 74.62800 74.96600 78.96900 78.90700 99 09/20/93:10:00:00 74.72300 72.76000 74.74300 74.94500 78.94800 78.87500 100 09/20/93:10:15:00 74.80400 72.71900 74.85100 75.34900 78.91600 78.84100 101 09/20/93:10:30:00 74.87800 73.07200 74.89800 75.41700 78.88200 78.81000 102 09/20/93:10:45:00 74.95900 73.03800 75.03300 75.57800 78.85100 78.78900 103 09/20/93:11:00:00 75.11400 72.88900 74.97900 75.62500 78.81700 78.74400 104 09/20/93:11:15:00 75.16100 73.40400 75.06700 76.10200 78.80800 78.72400 105 09/20/93:11:30:00 75.23500 73.32300 75.08700 76.16900 78.77400 78.70100 106 09/20/93:11:45:00 75.36300 73.00400 75.22200 75.71300 78.75300 78.68100 107 09/20/93:12:00:00 75.45000 73.62800 75.26200 75.91400 78.73800 78.66500 108 09/20/93:12:15:00 75.52400 73.52000 75.30900 76.14900 78.71000 78.63800 109 09/20/93:12:30:00 75.57800 73.35700 75.40300 76.28300 78.68300 78.59900 110 09/20/93:12:45:00 75.65200 73.33700 75.58500 75.90100 78.68300 78.59900 111 09/20/93:13:00:00 75.71300 73.83800 75.53800 76.31000 78.66100 78.57900 112 09/20/93:13:15:00 75.80700 73.77000 75.60500 76.49100 78.64500 78.56100 113 09/20/93:13:30:00 75.83300 73.67500 75.72600 76.67800 78.62200 78.53800 114 09/20/93:13:45:00 75.98100 73.79700 75.76600 76.23600 78.61100 78.52900 115 09/20/93:14:00:00 75.98800 74.08100 75.87400 76.57100 78.59000 78.50700 116 09/20/93:14:15:00 76.08900 73.97300 75.89400 76.53100 78.57900 78.49500 117 09/20/93:14:30:00 76.19600 74.25700 76.02800 76.93900 78.56800 78.48600 118 09/20/93:14:45:00 76.23600 74.08800 76.02100 77.14600 78.55900 78.47500 119 09/20/93:15:00:00 76.35700 74.18900 76.17600 77.26600 78.53600 78.46400 120 09/20/93:15:15:00 76.35700 74.31800 76.19600 77.78600 78.53600 78.45200
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 3 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 4
TABLE C DEW POINT TEMPERATURE SENSOR READINGS (DEG F)
DATA SENSOR NUMBER SET REAL TIME 1
2 3
4 5
6 121 09/20/93:15:30:00 76.41700 74.62800 76.27000 77.17300 78.51300 78.43200 122 09/20/93:15:45:00 76.63100 74.43900 76.31700 76.89900 78.52000 78.42700 123 09/20/93:16:00:00 76.61100 74.55400 76.45700 77.00600 78.49300 78.40900 124 09/20/93:16:15:00 76.70500 74.52000 76.57100 77.24600 78.49300 78.39800 125 09/20/93:16:30:00 76.71800 74.75700 76.48400 77.55300 78.45900 78.37800 126 09/20/93:16:45:00 76.79900 74.57400 76.67800 77.54600 78.45000 78.36600 127 09/20/93:17:00:00 76.95900 74.55400 76.65100 77.17300 78.43900 78.34400 128 09/20/93:17:15:00 76.95200 75.06700 76.81200 77.87900 78.42700 78.33200 129 09/20/93:17:30:00 77.01200 74.66900 76.85900 77.48600 78.41600 78.32300 130 09/20/93:17:45:00 77.10600 75.24200 76.93900 78.25100 78.40700 78.32300 131 09/20/93:18:00:00 77.12600 74.94500 76.97900 77.79900 78.39600 78.30100 132 09/20/93:18:15:00 77.16600 75.08700 76.99900 77.90600 78.39600 78.28900 133 09/20/93:18:30:00 77.22600 75.24800 77.07900 77.91900 78.37300 78.28000 134 09/20/93:18:45:00 77.27300 75.48400 77.17900 78.47700 78.38000 78.27600 135 09/20/93:19:00:00 77.33300 75.14100 77.28600 78.44300 78.36200 78.25800 136 09/20/93:19:15:00 77.45300 75.24200 77.31300 78.26400 78.35300 78.25800 137 09/20/93:19:30:00 77.51300 75.61200 77.36600 78.54900 78.34100 78.24600 138 09/20/93:19:45:00 77.52600 75.39700 77.42600 77.84600 78.34100 78.24600 139 09/20/93:20:00:00 77.56600 75.51800 77.48600 78.20500 78.33000 78.23500 140 09/20/93:20:15:00 77.67900 75.91400 77.58600 78.27800 78.32500 78.23000 141 09/20/93:20:30:00 77.76600 75.73900 77.67300 78.05800 78.31900 78.21500 142 09/20/93:20:45:00 77.79200 76.02800 77.73900 78.00500 78.31400 78.21000 143 09/20/93:21:00:00 77.85200 75.72600 77.63300 78.36400 78.30500 78.19900 144 09/20/93:21:15:00 77.89200 75.94800 77.77300 78.67500 78.29800 78.19200 145 09/20/93:21:30:00 77.92500 76.02800 77.77900 78.68900 78.27600 78.18100
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 4 UESC G100 VERSION 3.1 PAGE 1
TABLE D PRESSURE SENSOR READINGS SENSOR NUMBER 2
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 09/19/93:17:57:00 09/19/93:18:12:00 09/19/93:18:27:00 09/19/93:18:42:00 09/19/93:18:57:00 09/19/93:19:12:00 09/19/93:19:27:00 09/19/93:19:42:00 09/19/93:19:57:00 09/19/93:20:12:00 09/19/93:20:27:00 09/19/93:20:42:00 09/19/93:20:57:00 09/19/93:21:12:00 09/19/93:21:27:00 09/19/93:21:42:00 09/19/93:21:57:00 09/19/93:22:12:00 09/19/93:22:27:00 09/19/93:22:42:00 09/19/93:22:57:00 09/19/93:23:12:00 09/19/93:23:27:00 09/19/93:23:42:00 09/19/93:23:57:00 09/20/93:00:12:00 09/20/93:00:27:00 09/20/93:00:42:00 09/20/93:00:57:00 09/20/93:01:12:00 09/20/93:01:27:00 09/20/93:01:42:00 09/20/93:01:57:00 09/20/93:02:12:00 09/20/93:02:27:00 09/20/93:02:42:00 09/20/93:02:50:35 09/20/93:03:00:00 09/20/93:03:05:00 09/20/93:03:10:00 DATA SET REAL TIME 1
3 14.39600 14.86200 15.47400 16.10900 16.78500 17.57300 18.35800 19.66700 21.14300 22.61900 24.09600 25.56800 27.04500 28.51700 29.98800 31.45800 32.93800 34.41700 35.89100 37.37700 38.84800 40.33100 41.84700 43.47800 45.09300 46.70700 48.30200 49.88000 51.45400 53.03600 54.72000 56.12700 56.99400 57.84800 58.35600 58.77200 59.01700 58.98300 58.97400 58.96700 14.38700 14.85700 15.46700 16.10300 16.78000 17.56300 18.34800 19.65400 21.13500 22.60700 24.08200 25.56600 27.03800 28.50400 29.97900 31.45300 32.92700 34.40600 35.88200 37.36800 38.83600 40.31900 41.84100 43.46300 45.07400 46.69500 48.29000 49.87000 51.44500 53.02500 54.57500 56.11500 56.98000 57.83500 58.34200 58.75900 59.01400 58.96900 58.96000 58.95300 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 4 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 2
TABLE D PRESSURE SENSOR READINGS DATA SENSOR NUMBER SET REAL TIME 1
2 3
41 09/20/93:03:15:00 58.96100 58.94700 0.00000 42 09/20/93:03:20:00 58.95700 58.94200 0.00000 43 09/20/93:03:25:00 58.95300 58.93800 0.00000 44 09/20/93:03:30:00 58.94900 58.93500 0.00000 45 09/20/93:03:35:00 58.94600 58.93200 0.00000 46 09/20/93:03:40:00 58.94300 58.92900 0.00000 47 09/20/93:03:45:00 58.94000 58.92600 0.00000 48 09/20/93:03:50:00 58.93700 58.92300 0.00000 49 09/20/93:03:55:00 58.93500 58.92100 0.00000 50 09/20/93:04:00:00 58.93300 58.91800 0.00000 51 09/20/93:04:05:00 58.93100 58.91700 0.00000 52 09/20/93:04:10:00 58.92900 58.91400 0.00000 53 09/20/93:04:15:00 58.92700 58.91200 0.00000 54 09/20/93:04:20:00 58.92500 58.91000 0.00000 55 09/20/93:04:25:00 58.92300 58.90800 0.00000 56 09/20/93:04:30:00 58.92100 58.90600 0.00000 57 09/20/93:04:35:00 58.91900 58.90400 0.00000 58 09/20/93:04:40:00 58.91700 58.90300 0.00000 59 09/20/93:04:45:00 58.91500 58.90100 0.00000 60 09/20/93:04:50:00 58.91400 58.89900 0.00000 61 09/20/93:04:55:00 58.91300 58.89900 0.00000 62 09/20/93:05:00:00 58.91200 58.89800 0.00000 63 09/20/93:05:05:00 58.91200 58.89700 0.00000 64 09/20/93:05:10:00 58.91100 58.89700 0.00000 65 09/20/93:05:15:00 58.91100 58.89800 0.00000 66 09/20/93:05:20:00 58.91100 58.89700 0.00000 67 09/20/93:05:25:00 58.91100 58.89700 0.00000 68 09/20/93:05:30:00 58.91100 58.89600 0.00000 69 09/20/93:05:35:00 58.91100 58.89600 0.00000 70 09/20/93:05:40:00 58.91000 58.89600 0.00000 71 09/20/93:05:45:00 58.91000 58.89600 0.00000 72 09/20/93:05:50:00 58.91000 58.89600 0.00000 73 09/20/93:05:55:00 58.91000 58.89600 0.00000 74 09/20/93:06:00:00 58.91000 58.89600 0.00000 75 09/20/93:06:05:00 58.91000 58.89600 0.00000 76 09/20/93:06:10:00 58.91000 58.89500 0.00000 77 09/20/93:06:15:00 58.90900 58.89500 0.00000 78 09/20/93:06:20:00 58.90900 58.89500 0.00000 79 09/20/93:06:25:00 58.90900 58.89500 0.00000 80 09/20/93:06:30:00 58.90900 58.89500 0.00000
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 4 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 3
TABLE D PRESSURE SENSOR READINGS DATA SENSOR NUMBER SET REAL TIME 1
2 3
81 09/20/93:06:35:00 58.90900 58.89500 0.00000 82 09/20/93:06:40:00 58.90900 58.89500 0.00000 83 09/20/93:06:45:00 58.91000 58.89500 0.00000 84 09/20/93:06:50:00 58.91000 58.89600 0.00000 85 09/20/93:06:55:00 58.91000 58.89600 0.00000 86 09/20/93:07:00:00 58.91000 58.89600 0.00000 87 09/20/93:07:05:00 58.91000 58.89600 0.00000 88 09/20/93:07:15:00 58.91100 58.89600 0.00000 89 09/20/93:07:30:00 58.91100 58.89700 0.00000 90 09/20/93:07:45:00 58.91200 58.89800 0.00000 91 09/20/93:08:00:00 58.91300 58.89900 0.00000 92 09/20/93:08:15:00 58.91400 58.90000 0.00000 93 09/20/93:08:30:00 58.91600 58.90100 0.00000 94 09/20/93:08:45:00 58.91700 58.90300 0.00000 95 09/20/93:09:00:00 58.91800 58.90400 0.00000 96 09/20/93:09:15:00 58.92000 58.90600 0.00000 97 09/20/93:09:30:00 58.92100 58.90700 0.00000 98 09/20/93:09:45:00 58.92300 58.90900 0.00000 99 09/20/93:10:00:00 58.92400 58.91000 0.00000 100 09/20/93:10:15:00 58.92600 58.91200 0.00000 101 09/20/93:10:30:00 58.92700 58.91300 0.00000 102 09/20/93:10:45:00 58.92900 58.91500 0.00000 103 09/20/93:11:00:00 58.93100 58.91700 0.00000 104 09/20/93:11:15:00 58.93300 58.91900 0.00000 105 09/20/93:11:30:00 58.93500 58.92100 0.00000 106 09/20/93:11:45:00 58.93700 58.92200 0.00000 107 09/20/93:12:00:00 58.93800 58.92400 0.00000 108 09/20/93:12:15:00 58.94000 58.92600 0.00000 109 09/20/93:12:30:00 58.94200 58.92800 0.00000 110 09/20/93:12:45:00 58.94400 58.93000 0.00000 111 09/20/93:13:00:00 58.94600 58.93200 0.00000 112 09/20/93:13:15:00 58.94800 58.93400 0.00000 113 09/20/93:13:30:00 58.95000 58.93600 0.00000 114 09/20/93:13:45:00 58.95200 58.93800 0.00000 115 09/20/93:14:00:00 58.95400 58.94000 0.00000 116 09/20/93:14:15:00 58.95700 58.94200 0.00000 117 09/20/93:14:30:00 58.95900 58.94500 0.00000 118 09/20/93:14:45:00 58.96100 58.94700 0.00000 119 09/20/93:15:00:00 58.96300 58.94900 0.00000 120 09/20/93:15:15:00 58.96500 58.95100 0.00000
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 4 UESC G100 VERSION 3.1 PAGE 4
TABLE D PRESSURE SENSOR READINGS SENSOR NUMBER 2
121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 09/20/93:15:30:00 09/20/93:15:45:00 09/20/93:16:00:00 09/20/93:16:15:00 09/20/93:16:30:00 09/20/93:16:45:00 09/20/93:17:00:00 09/20/93:17:15:00 09/20/93:17:30:00 09/20/93:17:45:00 09/20/93:18:00:00 09/20/93:18:15:00 09/20/93:18:30:00 09/20/93:18:45:00 09/20/93:19:00:00 09/20/93:19:15:00 09/20/93:19:30:00 09/20/93:19:45:00 09/20/93:20:00:00 09/20/93:20:15:00 09/20/93:20:30:00 09/20/93:20:45:00 09/20/93:21:00:00 09/20/93:21:15:00 09/20/93:21:30:00 DATA SET REAL TIME 1
3 58.96700 58.96900 58.97200 58.97100 58.96100 58.95000 58.94000 58.93100 58.92100 58.91100 58.90100 58.89100 58.88100 58.87200 58.86200 58.85100 58.84200 58.83200 58.82200 58.81300 58.80300 58.79300 58.78300 58.77300 58.76300 58.95300 58.95500 58.95800 58.95700 58.94600 58.93600 58.92600 58.91700 58.90700 58.89600 58.88700 58.87700 58.86700 58.85800 58.84800 58.83700 58.82800 58.81800 58.80800 58.80500 58.78900 58.77900 58.76900 58.75900 58.74900 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 5 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 1
TABLE 4 CONTAINMENT TEMPERATURE STABILITY PARAMETERS TIME TEMPERATURE MASS POINT TOTAL TIME DATA ELAPSED AVG Tstab Lam UCL Lam UCL SET REAL (HRS)
(F)
(F/HR) (%/DAY)
(%/DAY)
(%/DAY)
(%/DAY) 51 09/20/93:03:00:00 0.00 84.810
-0.790 0.0000 0.0000 0.0000 0.0000 S2 09/20/93:03:05:00 0.08 84.691
-0.867
-2.1742 0.0000
-2.1742 0.0000 S3 09/20/93:03:10:00 0.17 84.610
-0.875
-1.7312 0.0000 -1.7393 0.0000 S4 09/20/93:03:15:00 0.25 84.546
-0.908 -1.5026
-0.9966
-1.5220 -0.7855 SS 09/20/93:03:20:00 0.33 84.491
-0.877
-1.2790
-0.8878
-1.2927
-0.9184 S6 09/20/93:03:25:00 0.42 84.448 -0.834
-1.1891
-0.9348
-1.2574
-0.6489 S7 09/20/93:03:30:00 0.50 84.399
-0.722
-1.0345
-0.7862
-1.0533
-0.5914 S8 09/20/93:03:35:00 0.58 84.370
-0.682
-0.9480 -0.7437
-1.0127
-0.4965 S9 09/20/93:03:40:00 0.67 84.341 -0.642
-0.8397
-0.6463
-0.8795
-0.3927 SlO 09/20/93:03:45:00 0.75 84.309
-0.557
-0.7476
-0.5665
-0.7980 -0.3128 Sl 09/20/93:03:50:00 0.83 84.274 -0.529
-0.7277
-0.5802
-0.8606
-0.2280 S12 09/20/93:03:55:00 0.92 84.247
-0.545
-0.6773
-0.5453
-0.7565
-0.1543 513 09/20/93:04:00:00 1.00 84.229
-0.325
-0.6376
-0.5197
-0.7263 -0.1049 S14 09/20/93:04:05:00 1.08 84.206 -0.228
-0.5920
-0.4811
-0.6634
-0.0597 S15 09/20/93:04:10:00 1.17 84.189 -0.166
-0.5600
-0.4592
-0.6521
-0.0064 S16 09/20/93:04:15:00 1.25 84.165
-0.074
-0.5097
-0.4082
-0.5584 0.0327 S17 09/20/93:04:20:00 1.33 84.138
-0.045
-0.4970
-0.4069
-0.6250 0.0668 518 09/20/93:04:25:00 1.42 84.122
-0.021
-0.4636
-0.3772
-0.5359 0.1083 S19 09/20/93:04:30:00 1.50 84.110 0.061
-0.4348
-0.3525
-0.5139 0.1368 S20 09/20/93:04:35:00 1.58 84.099 0.075
-0.3956
-0.3119
-0.4425 0.1670 S21 09/20/93:04:40:00 1.67 84.083 0.084 -0.3636
-0.2817
-0.4294 0.2037 S22 09/20/93:04:45:00 1.75 84.066 0.144 -0.3366
-0.2576
-0.4138 0.2295 S23 09/20/93:04:50:00 1.83 84.048 0.158 -0.3252
-0.2523
-0.4488 0.2521 S24 09/20/93:04:55:00 1.92 84.037 0.169
-0.3066
-0.2376
-0.4009 0.2812 S25 09/20/93:05:00:00 2.00 84.019 0.213
-0.2980
-0.2340
-0.4232 0.2995 526 09/20/93:05:05:00 2.08 84.008 0.219
-0.2841
-0.2235
-0.3846 0.3173 S27 09/20/93:05:10:00 2.17 84.001 0.223
-0.2755
-0.2189
-0.3930 0.3395 S28 09/20/93:05:15:00 2.25 83.999 0.292
-0.2682
-0.2152
-0.3860 0.3533 S29 09/20/93:05:20:00 2.33 83.988 0.302
-0.2689
-0.2197
-0.4168 0.3649 S30 09/20/93:05:25:00 2.42 83.989 0.309
-0.2652
-0.2192
-0.3882 0.3812 S31 09/20/93:05:30:00 2.50 83.988 0.360 -0.2549
-0.2107
-0.3441 0.3917 S32 09/20/93:05:35:00 2.58 83.983 0.358 -0.2513
-0.2097
-0.3688 0.4005 S33 09/20/93:05:40:00 2.67 83.983 0.364 -0.2422
-0.2022
-0.3296 0.4146 S34 09/20/93:05:45:00 2.75 83.982 0.421 -0.2316
-0.1926
-0.3091 0.4234 S35 09/20/93:05:50:00 2.83 83.980 0.428 -0.2239
-0.1864
-0.3139 0.4313 S36 09/20/93:05:55:00 2.92 83.982 0.429
-0.2150
-0.1786
-0.2960 0.4436 S37 09/20/93:06:00:00 3.00 83.974 0.377 -0.2069
-0.1716
-0.2902 0.4507 S38 09/20/93:06:05:00 3.08 83.972 0.379
-0.2019
-0.1682
-0.3007 0.4569 539 09/20/93:06:10:00 3.17 83.976 0.380 -0.1958
-0.1632
-0.2848 0.4670 S40 09/20/93:06:15:00 3.25 83.977 0.368 -0.1870
-0.1550
-0.2585 0.4733 S41 09/20/93:06:20:00 3.33. 83.966 0.363 -0.1821
-0.1512
-0.2748 0.4786 Temperature Stabilization Criteria =
.5 0F/HR
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 5 UESC G100 VERSION 3.1 PAGE 2
TABLE 4 CONTAINMENT TEMPERATURE STABILITY PARAMETERS TIME TEMPERATURE MASS POINT TOTAL TIME DATA ELAPSED AVG Tstab Lam UCL Lam UCL SET REAL (HRS)
(F)
(F/HR) (%/DAY)
(%/DAY) (%/DAY)
(%/DAY) 09/20/93:06:25:00 09/20/93:06:30:00 09/20/93:06:35:00 09/20/93:06:40:00 09/20/93:06:45:00 09/20/93:06:50:00 09/20/93:06:55:00 09/20/93:07:00:00 09/20/93:07:05:00 09/20/93:07:15:00 09/20/93:07:30:00 3.42 3.50 3.58 3.67 3.75 3.83 3.92 4.00 4.08 4.25 4.50 83.964 83.962 83.972 83.962 83.966 83.964 83.968 83.967 83.959 83.963 83.974 0.352 0.303 0.309 0.295 0.266 0.260 0.254 0.204 0.170 0.132 0.094
-0.1759
-0.1697
-0.1621
-0.1572
-0.1535
-0.1498
-0.1474
-0.1433
-0.1422
-0.1391
-0.1331
-0.1459
-0.1405
-0.1333
-0.1292
-0.1266
-0.1238
-0.1223
-0.1190
-0.1189
-0.1165
-0.1109
-0.2590
-0.2506
-0.2315
-0.2435
-0.2468
-0.2406
-0.2454
-0.2277
-0.2474
-0.2249
-0.1967 0.4876 0.4926 0.4979 0.5057 0.5094 0.5131 0.5193 0.5225 0.5248 0.5529 0.6003 Temperature Stabilization Criteria =
.5 oF/HR S42 S43 S44 S45 S46 S47 S48 S49 S50 S51 S52
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 6 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 1
TABLE 4A CONTAINMENT MASS POINT LEAKAGE STABILITY TIME TOTAL SLIDING DATA ELAPSED Lam UCL
.25*La L2H L1H L2H-L1HI SET REAL (HRS)
(%/DAY)
(%/DAY) (%/DAY)
(%/DAY)
(%/DAY) (%/DAY)
Sl 09/20/93:03:00:00 0.00 0.0000 0.0000 0.5000 0.0000 0.0000 0.0000 S2 09/20/93:03:05:00 0.08 -2.1742 0.0000 0.5000 0.0000 0.0000 0.0000 S3 09/20/93:03:10:00 0.17
-1.7312 0.0000 0.5000 0.0000 0.0000 0.0000 S4 09/20/93:03:15:00 0.25
-1.5026
-0.9966 0.5000 0.0000 0.0000 0.0000 S5 09/20/93:03:20:00 0.33
-1.2790
-0.8878 0.5000 0.0000 0.0000 0.0000 S6 09/20/93:03:25:00 0.42
-1.1891
-0.9348 0.5000 0.0000 0.0000 0.0000 S7 09/20/93:03:30:00 0.50
-1.0345
-0.7862 0.5000 0.0000 0.0000 0.0000 S8 09/20/93:03:35:00 0.58 -0.9480
-0.7437 0.5000 0.0000 0.0000 0.0000 S9 09/20/93:03:40:00 0.67
-0.8397
-0.6463 0.5000 0.0000 0.0000 0.0000 S1O 09/20/93:03:45:00 0.75
-0.7476
-0.5665 0.5000 0.0000 0.0000 0.0000 Sl 09/20/93:03:50:00 0.83
-0.7277
-0.5802 0.5000 0.0000 0.0000 0.0000 S12 09/20/93:03:55:00 0.92
-0.6773
-0.5453 0.5000 0.0000 0.0000 0.0000 513 09/20/93:04:00:00 1.00
-0.6376
-0.5197 0.5000 0.0000 0.0000 0.0000 514 09/20/93:04:05:00 1.08
-0.5920
-0.4811 0.5000 0.0000 0.0000 0.0000 S15 09/20/93:04:10:00 1.17
-0.5600
-0.4592 0.5000 0.0000 0.0000 0.0000 S16 09/20/93:04:15:00 1.25
-0.5097
-0.4082 0.5000 0.0000 0.0000 0.0000 517 09/20/93:04:20:00 1.33
-0.4970
-0.4069 0.5000 0.0000 0.0000 0.0000 S18 09/20/93:04:25:00 1.42
-0.4636
-0.3772 0.5000 0.0000 0.0000 0.0000 519 09/20/93:04:30:00 1.50
-0.4348
-0.3525 0.5000 0.0000 0.0000 0.0000 520 09/20/93:04:35:00 1.58
-0.3956
-0.3119 0.5000 0.0000 0.0000 0.0000 521 09/20/93:04:40:00 1.67
-0.3636
-0.2817 0.5000 0.0000 0.0000 0.0000 S22 09/20/93:04:45:00 1.75
-0.3366
-0.2576 0.5000 0.0000 0.0000 0.0000 S23 09/20/93:04:50:00 1.83
-0.3252
-0.2523 0.5000 0.0000 0.0000 0.0000 S24 09/20/93:04:55:00 1.92
-0.3066
-0.2376 0.5000 0.0000 0.0000 0.0000 S25 09/20/93:05:00:00 2.00
-0.2980
-0.2340 0.5000 0.0000 0.0000 0.0000 S26 09/20/93:05:05:00 2.08
-0.2841
-0.2235 0.5000
-0.2450 -0.0689 0.1761 S27 09/20/93:05:10:00 2.17
-0.2755
-0.2189 0.5000
-0.2110 -0.0831 0.1280 S28 09/20/93:05:15:00 2.25
-0.2682
-0.2152 0.5000
-0.1873 -0.1156 0.0717 S29 09/20/93:05:20:00 2.33
-0.2689
-0.2197 0.5000
-0.1798 -0.1519 0.0279 S30 09/20/93:05:25:00 2.42
-0.2652
-0.2192 0.5000
-0.1688 -0.2198 0.0510 S31 09/20/93:05:30:00 2.50
-0.2549
-0.2107 0.5000
-0.1565 -0.2158 0.0593 S32 09/20/93:05:35:00 2.58
-0.2513
-0.2097 0.5000
-0.1512 -0.2467 0.0955 S33 09/20/93:05:40:00 2.67
-0.2422
-0.2022 0.5000
-0.1412 -0.2038 0.0626 S34 09/20/93:05:45:00 2.75
-0.2316
-0.1926 0.5000
-0.1254 -0.1454 0.0200 S35 09/20/93:05:50:00 2.83
-0.2239
-0.1864 0.5000
-0.1127 -0.0971 0.0155 S36 09/20/93:05:55:00 2.92
-0.2150
-0.1786 0.5000
-0.1084 -0.0730 0.0354 S37 09/20/93:06:00:00 3.00
-0.2069
-0.1716 0.5000
-0.1013 -0.0249 0.0763 S38 09/20/93:06:05:00 3.08
-0.2019
-0.1682 0.5000
-0.1024 -0.0275 0.0748 S39 09/20/93:06:10:00 3.17
-0.1958
-0.1632 0.5000
-0.0978 0.0061 0.1039 S40 09/20/93:06:15:00 3.25
-0.1870
-0.1550 0.5000
-0.0901 0.0465 0.1366 S41 09/20/93:06:20:00 3.33
-0.1821
-0.1512 0.5000
-0.0823 0.0494 0.1317 Leakage Stabilization Criteria = IL2H-L1HI <=.25La
INTEGRATED LEAK RATE TEST RESULTS 10/18/93 RUN ID 82323315 ATTACHMENT 6 UESC G100 VERSION 3.1 PAGE 2
TABLE 4A CONTAINMENT MASS POINT LEAKAGE STABILITY TIME TOTAL SLIDING DATA ELAPSED Lam UCL
.25*La L2H L1H IL2H-L1H SET REAL (HRS)
(%IDAY)
(%/DAY)
(%/DAY)
(%/DAY)
(%/DAY) (%/DAY)
S42 09/20/93:06:25:00 S43 09/20/93:06:30:00 S44 09/20/93:06:35:00 S45 09/20/93:06:40:00 S46 09/20/93:06:45:00 S47 09/20/93:06:50:00 S48 09/20/93:06:55:00 S49 09/20/93:07:00:00 S50 09/20/93:07:05:00 S51 09/20/93:07:15:00 S52 09/20/93:07:30:00 3.42
-0.1759
-0.1459 0.5000
-0.0852 3.50 -0.1697
-0.1405 0.5000
-0.0782 3.58 -0.1621
-0.1333 0.5000
-0.0660 3.67
-0.1572
-0.1292 0.5000
-0.0518 3.75
-0.1535
-0.1266 0.5000
-0.0415 3.83
-0.1498
-0.1238 0.5000
-0.0297 3.92
-0.1474
-0.1223 0.5000
-0.0322 4.00 -0.1433
-0.1190 0.5000
-0.0215 4.08 -0.1422
-0.1189 0.5000
-0.0297 4.25
-0.1391
-0.1165 0.5000
-0.0217 4.50 -0.1331
-0.1109 0.5000
-0.0325 Leakage Stabilization Criteria = IL2H-L1H
<=.25La 0.0194 0.0022 0.0361
-0.0191
-0. 0197
-0.0496
-0.0431
-0.0752
-0.1209
-0.0683 0.1046 0.0803 0.1021 0.0518 0.0224 0.0100 0.0174 0.0216 0.0455 0.0992 0.0358
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 7 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 1
TABLE 2 TYPE A TEST LEAKAGE AND ERROR PARAMETERS TIME MASS POINT TOTAL TIME DATA ELAPSED Lam UCL Lam LS FIT UCL SET REAL (HRS)
(%DAY)
(%/DAY)
(%/DAY)
(%/DAY)
(%/DAY)
Al 09/20/93:07:45:00 0.00 0.00000 0.00000 0.00000 0.00000 0.00000 A2 09/20/93:08:00:00 0.25 0.32110 0.00000 0.32110 0.00000 0.00000 A3 09/20/93:08:15:00 0.50 0.17949 0.00000 0.17949 0.17949 0.00000 A4 09/20/93:08:30:00 0.75 0.11047 0.26958 0.11853 0.10509 0.42406 A5 09/20/93:08:45:00 1.00 0.09926 0.17434 0.11976 0.08497 0.33901 A6 09/20/93:09:00:00 1.25 0.07896 0.13000 0.09173 0.06243 0.25316 A7 09/20/93:09:15:00 1.50 0.06426 0.10242 0.07801 0.04590 0.20948 A8 09/20/93:09:30:00 1.75 0.06671 0.09428 0.09075 0.04411 0.20421 A9 09/20/93:09:45:00 2.00 0.04109 0.07600 0.03756 0.02220 0.16159 A10 09/20/93:10:00:00 2.25 0.03786 0.06541 0.05793 0.01660 0.15145 All 09/20/93:10:15:00 2.50 0.03547 0.05779 0.05456 0.01252 0.14373 A12 09/20/93:10:30:00 2.75 0.04955 0.07310 0.08936 0.02145 0.16109 A13 09/20/93:10:45:00 3.00 0.05725 0.07852 0.08399 0.02704 0.16735 A14 09/20/93:11:00:00 3.25 0.05339 0.07190 0.05851 0.02471 0.15920 A15 09/20/93:11:15:00 3.50 0.05682 0.07313 0.07511 0.02758 0.16001 A16 09/20/93:11:30:00 3.75 0.05801 0.07224 0.07054 0.02904 0.15842 A17 09/20/93:11:45:00 4.00 0.05305 0.06652 0.05138 0.02611 0.15055 A18 09/20/93:12:00:00 4.25 0.06000 0.07382 0.08642 0.03153 0.15622 A19 09/20/93:12:15:00 4.50 0.06236 0.07490 0.07576 0.03398 0.15659 A20 09/20/93:12:30:00 4.75 0.06177 0.07303 0.06653 0.03438 0.15397 A21 09/20/93:12:45:00 5.00 0.06308 0.07333 0.07306 0.03607 0.15346 A22 09/20/93:13:00:00 5.25 0.06631 0.07613 0.08156 0.03913 0.15515 A23 09/20/93:13:15:00 5.50 0.06846 0.07766 0.07962 0.04150 0.15582 A24 09/20/93:13:30:00 5.75 0.06866 0.07708 0.07278 0.04251 0.15458 A25 09/20/93:13:45:00 6.00 0.06944 0.07720 0.07542 0.04388 0.15399 A26 09/20/93:14:00:00 6.25 0.07123 0.07860 0.08072 0.04594 0.15450 A27 09/20/93:14:15:00 6.50 0.07072 0.07755 0.07099 0.04638 0.15284 A28 09/20/93:14:30:00 6.75 0.07263 0.07924 0.08258 0.04846 0.15356 A29 09/20/93:14:45:00 7.00 0.07321 0.07938 0.07728 0.04961 0.15306 A30 09/20/93:15:00:00 7.25 0.07406 0.07987 0.07911 0.05092 0.15285 A31 09/20/93:15:15:00 7.50 0.07627 0.08211 0.08732 0.05317 0.15403 A32 09/20/93:15:30:00 7.75 0.07698 0.08249 0.08064 0.05438 0.15381 A33 09/20/93:15:45:00 8.00 0.07761 0.08282 0.08080 0.05552 0.15356 Leakage Criteria.75La = 1.5000 %/DAY
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 8 UESC G100 10/21/93 VERSION 3.1.1 RUN ID 38538189 PAGE 1
TABLE 3 VERIFICATION TEST PARAMETERS MASS POINT TOTAL TIME DATA REAL Lo LIMIT < Lc
< LIMIT LIMIT <
Lc
< LIMIT SET TIME
(%/DAY)
(%/DAY) (%/DAY) (%/DAY)
(%/DAY) (%/DAY) (%/DAY)
Vi 09/20/93:16:30:00 1.97640 0.00000 0.00000 0.00000 0.00000 0.00000 0.00000 V2 09/20/93:16:45:00 1.97640 0.00000 2.18821 0.00000 0.00000 2.18822 0.00000 V3 09/20/93:17:00:00 1.97640 0.00000 1.98298 0.00000 0.00000 1.98297 0.00000 V4 09/20/93:17:15:00 1.97640 1.55401 2.05387 2.55401 1.55720 2.08454 2.55720 V5 09/20/93:17:30:00 1.97640 1.55401 2.01863 2.55401 1.55720 2.01509 2.55720 V6 09/20/93:17:45:00 1.97640 1.55401 2.07671 2.55401 1.55720 2.11123 2.55720 V7 09/20/93:18:00:00 1.97640 1.55401 2.05778 2.55401 1.55720 2.04375 2.55720 V8 09/20/93:18:15:00 1.97640 1.55401 2.05288 2.55401 1.55720 2.05088 2.55720 V9 09/20/93:18:30:00 1.97640 1.55401 2.05311 2.55401 1.55720 2.05583 2.55720 V10 09/20/93:18:45:00 1.97640 1.55401 2.06287 2.55401 1.55720 2.07519 2.55720 V11 09/20/93:19:00:00 1.97640 1.55401 2.05795 2.55401 1.55720 2.05141 2.55720 V12 09/20/93:19:15:00 1.97640 1.55401 2.05911 2.55401 1.55720 2.06147 2.55720 V13 09/20/93:19:30:00 1.97640 1.55401 2.06112 2.55401 1.55720 2.06458 2.55720 V14 09/20/93:19:45:00 1.97640 1.55401 2.05293 2.55401 1.55720 2.03884 2.55720 V15 09/20/93:20:00:00 1.97640 1.55401 2.04938 2.55401 1.55720 2.04491 2.55720 V16 09/20/93:20:15:00 1.97640 1.55401 2.05188 2.55401 1.55720 2.05998 2.55720 V17 09/20/93:20:30:00 1.97640 1.55401 2.04671 2.55401 1.55720 2.03746 2.55720 V18 09/20/93:20:45:00 1.97640 1.55401 2.04795 2.55401 1.55720 2.05439 2.55720 V19 09/20/93:21:00:00 1.97640 1.55401 2.04488 2.55401 1.55720 2.04005 2.55720 V20 09/20/93:21:15:00 1.97640 1.55401 2.04484 2.55401 1.55720 2.04844 2.55720 V21 09/20/93:21:30:00 1.97640 1.55401 2.04588 2.55401 1.55720 2.05236 2.55720 ILRT INSTRUMENTATION LIST III.ILRT Sensor Locations EQUIP ID RTD DW/T AZIMUTH DISTANCE ELEV.
ZONE FRACTIONS FROM CENTER TE4328A. TI T
270 55 735 T
0.1122 TE4328B T2 T
0 55 735 T
0.1123 TE4328C T3 T
90 55 735 T
0.1122 TE4328D T4 T
180 55 735 T
0.1123 TE4328E T5 DW 45 20 749 VII 0.055 TE4328F T6 DW 225 20 750 VII 0.055 TE4328G T7 DW 90 23 764 VI 0.065 TE4328H T8 DW 330 23 766 VI 0.066 TE4328J T9 DW 0
18 784 V
0.055 TE4328K T1O D
180 18 784 V
0.055 TE4328L T11 DW 20 15 828 I&II 0.040 TE4328M T12 DW 30 5
750 VIII 0.027 TE4328N T13+
DW 210 23 766 VI 0.066 TE4328P T14+
DW 270 15 802 IV 0.030 TE4328Q T15+
DW 180 15 817 III 0.037 TOTAL 1.000 Dewpoint ME4326A Ml+
DW 0
20 780 V
0.110 ME43268 M2+
DW 90 23 765 VI 0.197 ME4326C M3+
DW 225 20 750 VII, VII) 0.136 ME4326D M4+
DW 180 15 817 IIIIII 0.108 ME4326E MS+
T 270 55 735 T
0.2245 ME4326F M6+
T 90 55 735 T
0.2245 TOTAL 1.000
+ Temporary RTD and/or dewpoint sensors.
Vent header is included in torus volume when determining volume fractions.
0 ILRT INSTRUMENTATION IIRT TEMPERATURE DETECTOR LOCATIONS NOTES:
1 ZONE BOUNDARIES ARE APPROXIMATE, REFERENCE DAEC CAc. c.A-M1-.
. RTD ELEVATIONS AND AZIMUTH POSITIONS ARE APPROXIMATE 1
ILRT INSTRUMENTATION ILRT DEWPOINT TEMPERATURE SENSOR LOCATIONS 8
EL 74290 27D EL NOTES:
L ZONE 8OUNDARIES ARE APPROXIMATE, REFERENCE DAEC CALC CAvtL-at-c
& DEWPOINT TEMPERATURE SENSOR ELEYATIONS AND. AZIMUTH POSITIONS ARE APPROXIMATE
0 4
UESC G100 ILRT Results CONTAINMENT AIR MASS
~ -.
~
d I ~-4
-4 1..............
t...............
I.....
I.
I 2
3 4
DATASET DATE TIME Tdry Ptot Pvap Tdew Tstab 66800 66700 66600 66500 66400 66300 66200 66100 66000 S52
=
09/20/93 07:
30:
00 83.974
=
- 58.
911
-0.4437
=
75.934 0.094 66766
=
-0.0683
-0.0325 0.0358
-0. 1331
=
-0.1109 5
ELAPSED TIME (HOURS)
CONTAINMENT STABILIZATION L
/L2-L 1/
UESC G100 ILRT Results MASS POINT SLIDING LEAKAGE VS.25La
-/L2H-UIH/
---. 5La I
I 0
1
./......
2 3
4 DATASET DATE TIME S52 09/20/93 07:
30:
00 Tdry -
83.974 Ptot
=
58.911 Pvap 0.4437 Tdew =
75.934 Tstab 0.094 P
E R
C E
N T
p E
R D
A Y
0.590 0.490 0. 390 0.290
- 0. 190 0.090 010 I
5 ELAPSED TIME (HOURS)
CONTAINMENT STABILIZATION 66766
=
-0.0683
-0.0325 0.0358
-0.1331
=
/L2-L1/
UESC G100 ILRT Results TOTAL TIME LEAKAGE RATE AND UCL VS.75La Lam UCL
..............L.............
P E
R C
E N
T P
E R
D A
Y DATASET DATE TIME A33 09/20/93 15: 45: 00 Tdry 84.508 Ptot =
58.969 Rvap m 0.4594 Tdew
=
77.013 Tstab
-0.004 1. 700 1. 500 1. 300 1.100 0. 900 0. 700 0. 500 0. 300
- 0. 100 100 1
2 3
4 5
6 7
ELAPSED TIME (HOURS)
TYPE A TEST 8
9 10 N............
S C,
0 AIRMASS MR Lam MR UCL TT Lam TT LSQ TT UCL 0
a..............................
m..............
66749 0.0776 0.0828 0. 0808 0. 0555 0. 1536 I
UESC G100 ILRT Results TOTAL TIME LEAKAGE RATE VS VERIFICATION LIMITS DATASET V21 DATE
= 09/20/93 TIME 21:
30:
00 Tdry -
84.953 Ptot
=
58.763 Pvap 0.4711 Tdew =
77.750 Tstab
-0.007 P
E R
C E
N T
P E
R 0
A y
TT Lam
=
2.0524 TT LSq 2.0407 TT UCL
=
2.1306 0
1 2
3 4
5 6
7 8
9 10 ELAPSED TIME (HOURS)
VERIFICATION TEST z
ft MP UCL 2.900 2.400 1. 900 1.400 0.900 0.400 100 AIRMASS 66446 MP Lam
=
2.0459 2. 0545
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 16 10/18/93 RUN ID 82323315 UESC G100 VERSION 3.1 PAGE 1
TABLE 1 ILRT CONTAINMENT AIR.MASS CALCULATION PARAMETERS TIME PRESSURE TEMPERATURE MASS DATA ELAPSED TOTAL VAPOR DRY BULB DEW POINT AIR SET REAL (HRS)
(PSIA) (PSIA)
(DEG F)
(DEG F)
(LBM) 1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
'Aslk 41 09/19/93:17:57:00 09/19/93:18:12:00 09/19/93:18:27:00 09/19/93:18:42:00 09/19/93:18:57:00 09/19/93:19:12:00 09/19/93:19:27:00 09/19/93:19:42:00 09/19/93:19:57:00 09/19/93:20:12:00 09/19/93:20:27:00 09/19/93:20:42:00 09/19/93:20:57:00 09/19/93:21:12:00 09/19/93:21:27:00 09/19/93:21:42:00 09/19/93:21:57:00 09/19/93:22:12:00 09/19/93:22:27:00 09/19/93:22:42:00 09/19/93:22:57:00 09/19/93:23:12:00 09/19/93:23:27:00 09/19/93:23:42:00 09/19/93:23:57:00 09/20/93:00:12:00 09/20/93:00:27:00 09/20/93:00:42:00 09/20/93:00:57:00 09/20/93:01:12:00 09/20/93:01:27:00 09/20/93:01:42:00 09/20/93:01:57:00 09/20/93:02:12:00 09/20/93:02:27:00 09/20/93:02:42:00 09/20/93:02:50:35 09/20/93:03:00:00 09/20/93:03:05:00 09/20/93:03:10:00 09/20/93:03:15:00 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00 5.25 5.50 5.75 6.00 6.25 6.50 6.75 7.00 7.25 7.50 7.75 8.00 8.25 8.50 8.75 8.89 9.05 9.13 9.22 9.30 14.396 14.862 15.474 16.109 16.785 17.573 18.358 19.667 21.143 22.619 24.096 25.568 27.045 28.517 29.988 31.458 32.938 34.417 35.891 37.377 38.848 40.331 41.847 43.478 45.093 46.707 48.302 49.880 51.454 53.036 54.720 56.127 56.994 57.848 58.356 58.772 59.017 58.983 58.974 58.967 58.961 0.4152 0.4223 0.4229 0.4213 0.4241 0.4233 0.4227 0.4261 0.4275 0.4249 0.4270 0.4267 0.4260 0.4273 0.4280 0.4262 0.4267 0.4259 0.4278 0.4300 0.4280 0.4324 0.4352 0.4374 0.4404 0.4439 0.4461 0.4459 0.4512 0.4523 0.4524 0.4557 0.4520 0.4513 0.4474 0.4483 0.4481 0.4473 0.4469 0.4456 0.4444 79.147 79.815 80.367 80.623 80.813 81.117 81.313 82.156 82.613 82.881 83.109 83.299 83.480 83.644 83.791 83.955 84.108 84.255 84.382 84.509 84.634 84.760 84.924 85.128 85.268 85.411 85.527 85.632 85.731 85.852 85.940 86.027 85.685 85.555 85.293 85.106 85.060 84.810 84.691 84.610 84.546 73.977 74.468 74.510 74.399 74.587 74.538 74.491 74.725 74.821 74.642 74.791 74.772 74.721 74.813 74.861 74.737 74.767 74.717 74.843 74.994 74.856 75.164 75.350 75.507 75.707 75.949 76.102 76.087 76.451 76.530 76.533 76.758 76.506 76.456 76.190 76.253 76.239 76.186 76.158 76.068 75.984 16108.2 16616.3 17302.1 18025.4 18792.4 19687.3 20581.8 22045.6 23715.2 25395.3 27071.5 28745.4 30424.8 32096.0 33766.9 35437.5 37116.7 38795.5 40466.3 42149.6 43820.0 45495.8 47207.1 49045.4 50869.4 52690.2 54492.6 56278.9 58054.3 59840.3 61746.8 63333.9 64364.7 65353.2 65967.8 66463.5 66748.5 66741.3 66746.1 66749.5 66751.9
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 16 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 2 TABLE 1 ILRT CONTAINMENT AIR MASS CALCULATION PARAMETERS TIME PRESSURE TEMPERATURE MASS DATA ELAPSED TOTAL VAPOR DRY BULB DEW POINT AIR SET REAL (HRS)
(PSIA)
(PSIA)
(DEG F)
(DEG F)
(LBM) 42 09/20/93:03:20:00 9.38 58.957 0.4452 84.491 76.039 66753.1 43 09/20/93:03:25:00 9.47 58.953 0.4434 84.448 75.913 66756.0 44 09/20/93:03:30:00 9.55 58.949 0.4447 84.399 76.005 66755.9 45 09/20/93:03:35:00 9.63 58.946 0.4433 84.370 75.908 66757.6 46 09/20/93:03:40:00 9.72 58.943 0.4434 84.341 75.916 66757.7 47 09/20/93:03:45:00 9.80 58.940 0.4437 84.309 75.934 66757.9 48 09/20/93:03:50:00 9.88 58.937 0.4416 84.274 75.790 66761.1 49 09/20/93:03:55:00 9.97 58.935 0.4430 84.247 75.885 66760.6 50 09/20/93:04:00:00 10.05 58.933 0.4421 84.229 75.826 66761.5 51 09/20/93:04:05:00 10.13 58.931 0.4428 84.206 75.876 66761.2 52 09/20/93:04:10:00 10.22 58.929 0.4416 84.189 75.789 66762.5 53 09/20/93:04:15:00 10.30 58.927 0.4437 84.165 75.936 66760.7 54 09/20/93:04:20:00 10.38 58.925 0.4414 84.138 75.777 66764.4 55 09/20/93:04:25:00 10.47 58.923 0.4427 84.122 75.870 66762.4 56 09/20/93:04:30:00 10.55 58.921 0.4419 84.110 75.810 66762.7 57 09/20/93:04:35:00 10.63 58.919 0.4427 84.099 75.869 66760.7 58 09/20/93:04:40:00 10.72 58.917 0.4420 84.083 75.822 66761.2 59 09/20/93:04:45:00 10.80 58.915 0.4417 84.066 75.798 66761.4 60 09/20/93:04:50:00 10.88 58.914 0.4403 84.048 75.700 66764.1 61 09/20/93:04:55:00 10.97 58.913 0.4416 84.037 75.795 66762.7 62 09/20/93:05:00:00 11.05 58.912 0.4407 84.019 75.731 66764.8 63 09/20/93:05:05:00 11.13 58.912 0.4431 84.008 75.894 66763.5 64 09/20/93:05:10:00 11.22 58.911 0.4415 84.001 75.786 66765.0 65 09/20/93:05:15:00 11.30 58.911 0.4413 83.999 75.775 66765.4 66 09/20/93:05:20:00 11.38 58.911 0.4400 83.988 75.684 66768.3 67 09/20/93:05:25:00 11.47 58.911 0.4407 83.989 75.729 66767.4 68 09/20/93:05:30:00 11.55 58.911 0.4428 83.988 75.873 66765.2 69 09/20/93:05:35:00 11.63 58.911 0.4411 83.983 75.755 66767.7 70 09/20/93:05:40:00 11.72 58.910 0.4418 83.983 75.808 66765.8 71 09/20/93:05:45:00 11.80 58.910 0.4427 83.982 75.866 66764.9 72 09/20/93:05:50:00 11.88 58.910 0.4419 83.980 75.815 66766.0 73 09/20/93:05:55:00 11.97 58.910 0.4423 83.982 75.841 66765.3 74 09/20/93:06:00:00 12.05 58.910 0.4430 83.974 75.889 66765.5 75 09/20/93:06:05:00 12.13 58.910 0.4418 83.972 75.808 66767.0 76 09/20/93:06:10:00 12.22 58.910 0.4420 83.976 75.822 66766.4 77 09/20/93:06:15:00 12.30 58.909 0.4424 83.977 75.848 66764.6 78 09/20/93:06:20:00 12.38 58.909 0.4417 83.966 75.801 66766.7 79 09/20/93:06:25:00 12.47 58.909 0.4427 83.964 75.867 66765.9 80 09/20/93:06:30:00 12.55 58.909 0.4432 83.962 75.899 66765.7 81 09/20/93:06:35:00 12.63 58.909 0.4432 83.972 75.904 66764.3 82 09/20/93:06:40:00 12.72 58.909 0.4427 83.962 75.870 66766.1
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 16 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 3
TABLE 1 ILRT CONTAINMENT AIR MASS CALCULATION PARAMETERS TIME PRESSURE TEMPERATURE MASS DATA ELAPSED TOTAL VAPOR DRY BULB DEW POINT AIR SET REAL (HRS)
(PSIA) (PSIA)
(DEG F)
(DEG F)
(LBM) 83 09/20/93:06:45:00 12.80 58.910 0.4426 83.966 75.857 66767.0 84 09/20/93:06:50:00 12.88 58.910 0.4428 83.964 75.878 66766.9 85 09/20/93:06:55:00 12.97 58.910 0.4414 83.968 75.777 66768.0 86 09/20/93:07:00:00 13.05 58.910 0.4428 83.967 75.872 66766.6 87 09/20/93:07:05:00 13.13 58.910 0.4412 83.959 75.766 66769.3 88 09/20/93:07:15:00 13.30 58.911 0.4431 83.963 75.893 66767.9 89 09/20/93:07:30:00 13.55 58.911 0.4437 83.974 75.934 66765.9 90 09/20/93:07:45:00 13.80 58.912 0.4436 83.979 75.927 66766.5 91 09/20/93:08:00:00 14.05 58.913 0.4452 83.991 76.039 66764.3 92 09/20/93:08:15:00 14.30 58.914 0.4453 84.002 76.045 66764.0 93 09/20/93:08:30:00 14.55 58.916 0.4464 84.010 76.124 66764.0 94 09/20/93:08:45:00 14.80 58.917 0.4467 84.023 76.145 66763.2 95 09/20/93:09:00:00 15.05 58.918 0.4465 84.033 76.130 66763.3 96 09/20/93:09:15:00 15.30 58.920 0.4476 84.043 76.203 66763.3 97 09/20/93:09:30:00 15.55 58.921 0.4480 84.058 76.232 66762.1 98 09/20/93:09:45:00 15.80 58.923 0.4468 84.068 76.152 66764.4 99 09/20/93:10:00:00 16.05 58.924 0.4482 84.077 76.244 66762.9 100 09/20/93:10:15:00 16.30 58.926 0.4488 84.091 76.288 66762.7 101 09/20/93:10:30:00 16.55 58.927 0.4499 84.115 76.365 66759.7 102 09/20/93:10:45:00 16.80 58.929 0.4503 84.131 76.391 66759.5 103 09/20/93:11:00:00 17.05 58.931 0.4499 84.140 76.359 66761.2 104 09/20/93:11:15:00 17.30 58.933 0.4522 84.153 76.522 66759.2 105 09/20/93:11:30:00 17.55 58.935 0.4521 84.174 76.512 66759.2 106 09/20/93:11:45:00 17.80 58.937 0.4508 84.191 76.423 66760.8 107 09/20/93:12:00:00 18.05 58.938 0.4530 84.216 76.576 66756.3 108 09/20/93:12:15:00 18.30 58.940 0.4531 84.228 76.582 66757.0 109 09/20/93:12:30:00 18.55 58.942 0.4529 84.243 76.568 66757.7 110 09/20/93:12:45:00 18.80 58.944 0.4527 84.274 76.556 66756.4 111 09/20/93:13:00:00 19.05 58.946 0.4547 84.289 76.690 66754.6 112 09/20/93:13:15:00 19.30 58.948 0.4549 84.307 76.708 66754.3 113 09/20/93:13:30:00 19.55 58.950 0.4551 84.320 76.718 66754.9 114 09/20/93:13:45:00 19.80 58.952 0.4550 84.347 76.712 66753.9 115 09/20/93:14:00:00 20.05 58.954 0.4564 84.364 76.809 66752.5 116 09/20/93:14:15:00 20.30 58.957 0.4562 84.385 76.793 66753.7 117 09/20/93:14:30:00 20.55 58.959 0.4580 84.408 76.918 66751.0 118 09/20/93:14:45:00 20.80 58.961 0.4578 84.425 76.906 66751.5 119 09/20/93:15:00:00 21.05 58.963 0.4587 84.443 76.966 66750.6 120 09/20/93:15:15:00 21.30 58.965 0.4599 84.468 77.047 66748.3 121 09/20/93:15:30:00 21.55 58.967 0.4600 84.480 77.049 66749.1 122 09/20/93:15:45:00 21.80 58.969 0.4594 84.508 77.013 66748.5 123 09/20/93:16:00:00 22.05 58.972 0.4600 84.529 77.054 66748.7
INTEGRATED LEAK RATE TEST RESULTS ATTACHMENT 16 UESC G100 10/18/93 VERSION 3.1 RUN ID 82323315 PAGE 4
TABLE 1 ILRT CONTAINMENT AIR MASS CALCULATION PARAMETERS TIME PRESSURE TEMPERATURE MASS DATA ELAPSED TOTAL VAPOR DRY BULB DEW POINT AIR SET REAL (HRS)
(PSIA) (PSIA)
(DEG F)
(DEG F)
(LBM) 124 09/20/93:16:15:00 22.30 58.971 0.4607 84.543 77.096 66745.1 125 09/20/93:16:30:00 22.55 58.961 0.4616 84.555 77.154 66731.2 126 09/20/93:16:45:00 22.80 58.950 0.4615 84.577 77.147 66716.0 127 09/20/93:17:00:00 23.05 58.940 0.4609 84.591 77.110 66703.6 128 09/20/93:17:15:00 23.30 58.931 0.4640 84.608 77.303 66687.7 129 09/20/93:17:30:00 23.55 58.921 0.4622 84.634 77.190 66675.1 130 09/20/93:17:45:00 23.80 58.911 0.4656 84.651 77.405 66657.8 131 09/20/93:18:00:00 24.05 58.901 0.4639 84.671 77.298 66645.9 132 09/20/93:18:15:00 24.30 58.891 0.4646 84.690 77.342 66631.4 133 09/20/93:18:30:00 24.55 58.881 0.4653 84.709 77.385 66616.8 134 09/20/93:18:45:00 24.80 58.872 0.4673 84.733 77.512 66601.3 135 09/20/93:19:00:00 25.05 58.862 0.4664 84.753 77.453 66588.6 136 09/20/93:19:15:00 25.30 58.851 0.4666 84.771 77.469 66573.5 137 09/20/93:19:30:00 25.55 58.842 0.4684 84.790 77.581 66559.0 138 09/20/93:19:45:00 25.80 58.832 0.4667 84.811 77.472 66546.9 139 09/20/93:20:00:00 26.05 58.822 0.4678 84.828 77.542 66532.2 140 09/20/93:20:15:00 26.30 58.813 0.4695 84.857 77.652 66516.4 141 09/20/93:20:30:00 26.55 58.803 0.4689 84.867 77.611 66504.6 142 09/20/93:20:45:00 26.80 58.793 0.4699 84.897 77.671 66488.4 143 09/20/93:21:00:00 27.05 58.783 0.4693 84.910 77.638 66475.9 144 09/20/93:21:15:00 27.30 58.773 0.4709 84.928 77.736 66460.6 145 09/20/93:21:30:00 27.55 58.763 0.4711 84.953 77.750 66445.8
ATTACHMENT TYPE B 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM) 0 Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage TESTABLE X-1 X-2 X-4 X-6 X-35A X-35B X-35C X-35D X-53 X-58A X-58B GASKETS Personnel Lock Equip Door Equipment Access Hatch Drywell Head Access Hatch CRD Removal Hatch TIP Drive TIP Drive TIP Drive TIP Purge Line Spare Drywell Head Stabilizer Access Port Stabilizer Access Port 8
10 11 1642
.12 20 15 24 5
16 20 15 8
5 11 5
12 20 15 24 5
11 20 15 8/04/93 9/15/93 8/12/93 9/09/93 8/12/93 8/11/93 8/11/93 8/11/93 7/28/93 9/17/93 8/13/93 8/13/93 C,
z
-I I-.
ATTACHMENT TYPE B 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage TESTABLE GASKETS X-58C Stabilizer Access Port X-58D Stabilizer Access Port X-58E Stabilizer Access Port X-58F Stabilizer Access Port X-58G Stabilizer Access Port X-58H Stabilizer Access Port N-200A South Torus Access Hatch N-200B North Torus Access Hatch ELECTRICAL PENETRATIONS Combined X-100E,F,&G, X-103, X-104A,B Combined X-100B,C, X-104C,D Combined X-101C, X-105D, X-106C Combined X-101A, X-105B, X-106A N-230B Vacuum Breaker Cables 17 17 9
30 19 18 5
5 7
10 14 5
5 17 8/13/93 17 9
30 19 18 5
145 7
10 14 5
5 8/13/93 8/13/93 8/13/93 8/13/93 8/13/93 9/24/93 9/23/93 7/28/93 7/30/93 7/28/93 7/28/93 7/29/93 C-,
z
-I
is ATTACHMENT TYPE B 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage FLANGE O-RINGS X-25 Drywell Purge Outlet CV-4302 X-26 Drywell Purge Outlet CV-4307 N-205 Torus Purge Outlet CV-4300 N-213A South Torus Drain Line Flange N-213B North Torus Drain Line Flange N-220 Torus Purge Supply CV-4308 N-231 RB/Torus Vacuum Breaker CV-4304 N-231 RB/Torus Vacuum Breaker CV-4305 N-217 CS Discharge Relief, PSV-2109 N-218 CS Discharge Relief, PSV-2129 VALVE BONNETS X-39A Drywell Spray, MO-2000 N-211B Torus Spray, MO-2006 X-39B Drywell Spray, MO-1902 5
5 5
5 5
5 5
105 10 33 162 217 306 162 217 306 9/17/93 8/24/93 9/07/93 8/05/93 7/30/93 8/24/93 9/07/93 9/09/93 9/14/93 9/11/93 Replaced 0-Ring Replaced 0-Ring Replaced O-Ring Replaced Replaced Replaced O-Ring O-Ring O-Ring 8/26/93 8/26/93 9/14/93 N-211A Torus Spray, MO-1933 N
>n 17 17 9/14/93
ATTACHMENT TYPE B 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage EXPANSION X-7A X-7B X-7C X-7D X-9A X-9B X-10 X-11 X-12 X-13A X-13B X-15 X-16A X-16B BELLOWS Main Steam Line Main Steam Line Main Steam Line Main Steam Line Reactor Feedwater Reactor Feedwater RCIC Steam Supply HPCI Steam Supply RHR Shutdown Cooling Supply A RHR LPCI Inject B RHR LPCI Inject RWCU Supply A Core Spray Discharge B Core Spray Discharge 115 104 483 63 21 548 24 29 18 5
5 5
5 19 115 104 483 63 21 548 24 29 18 5
5 5
5 19 8/03/93 8/03/93 8/02/93 8/03/93 8/01/93 8/02/93 8/01/93 8/01/93 7/30/93 7/30/93 7/30/93 8/05/93 8/04/93 7/30/93 z
0s ATTACHMENT TYPE B 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage EXPANSION X-17 N-201A N-201C N-201B N-201D N-201E N-201G N-201F N-201H N-213A N-213A N-213B N-213B BELLOWS RHR Head Spray Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer South Torus Inbd Drain Line South Torus Outbd Drain Line North Torus Inbd Drain Line North Torus Outbd Drain Line 57 10 7
92 5
5 68 5
5 5
5 5
5 57 10 7
92 5
5 68 5
5 5
5 5
5 7/31/93 7/29/93 7/29/93 7/29/93 7/29/93 7/29/93 7/29/93 7/29/93 7/29/93 8/05/93 8/05/93 8/05/93 8/05/93 C.,
z
-4
0 ATTACHMENT TYPE B 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage SHAFT STEM SEALS X-26 Drywell Purge Supply, CV-4307 5
6 8/24/93 N-220 Torus Purge Supply, CV-4308 5
6 8/24/93 TOTAL TYPE B 4439 3067
ATTACHMENT TYPE C 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 7A Main Steam CV-4412 CV-4413 MO-8401A 7B Main Steam CV-4415 CV-4416 MO-8401B 7C Main Steam CV-4418 CV-4419 MO-8401C 7D Main Steam CV-4420 CV-4421 MO-8401D 5428 10520 400 4226 4226 16 2756 2756 198 5428 57773 15 10920 5428 5428 1672 5428 77 4242 2954 57788 4226 2756 5428 4226 4999 16 2756 580 198 5428 344 5015 2756 5428 4226 1749 Replaced seat, disc, and operator.
Rebuilt operator.
Repacked valve.
778 Repacked valve.
359 Machined seat, bore, replaced disc, oper.
15 8
Steam Drain 9A Feedwater MO-4423 MO-4424 V-14-03 MO-4441 MO-2312 155 110 366 86 155 366 110 86 155 186 366 29 186 366 155 29 Overhauled operator, repacked.
Rebuilt operator.
Overhauled operator.
z
ATTACHMENT TYPE C 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 9B 10 10 11 11 15 16A 16B 19 V-14-01 MO-2740 MO-2512 MO-4442 CV-2410 CV-2411 MO-2400 MO-2401 MO-2238 MO-2239 CV-2211 CV-2212 MO-2700 MO-2701 MO-2117 MO-2115 MO-2137 MO-2135 CV-3704 CV-3705 1685 209 1685 209 1685 1685 2249 249 Overhauled operator.
Rebuilt operator.
Feedwater RCIC Cond Rtn RCIC Steam HPCI Steam HPCI Cond Rtn RWCU Core Spray Core Spray Drywell Drain 209 2186 332 8
1096 23 30 28290 156 282 302 7
19 20 5
25640 209 156 923 1182 332 302 7
8 19 1028 20 23 7
30 2462 603 209 1182 332 8
1028 23 30 2462 156 923 302 7
19 20 7
603 Overhauled operator.
Overhauled operator.
Mid-cycle replaced stem, repacked.
Overhauled operator.
Repacked valve.
Replaced valve.
Replaced valve.
209 156 282 2186 332 302 7
8 19 1096 20 23 5
30 25640 28290 3C M
ATTACHMENT TYPE C 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 20 21 22 &
229A 23A 23B 24A 24B 25 32 29 11 713 244 463 594 1847 3287 901 252 32 11 957 Demin Water V-09-1 11 V-09-065 Service Air V-30-287 Blind Flange N2 Comp Disch V-43-214 CV-4371C CV-4371A DW Cool Supply CV-5718A V-57-077 DW Cool Supply CV-5718B V-57-078 DW Cool Return CV-5704A V-57-075 DW Cool Return CV-5704B V-57-076 DW Purge Out CV-4302 CV-4303 CV-4310 29 6
463 594 1847 3287 901 176 32 29 11 713 244 463 594 1847 3287 901 79 32 11 957 594 1847 3287 901 129 29 6
463 594 1847 3287 901 90 50 Replaced T-seal, overhauled operator.
Replaced T-seal, overhauled operator.
594 1847 3287 901 302
-)
50
ATTACHMENT TYPE C 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR DW Purge Sup CV-4306 282 282 141 205 205 103 CV-4307 CV-4308 Replaced T-seal, overhauled operator.
Replaced T-seal, overhauled operator.
Replaced T-seal, overhauled operator.
26&
DW & Torus M/UCV-4311 220 CV-4312 CV-4313 32 DN2 Comp Suc 32E Recirc A Seal 32F Recirc B Seal CV-4378A CV-4378B V-17-096 CV-1804A V-17-083 CV-1804B 35A TIP Check check 35B TIP Ball 35C TIP Ball ball ball 4394 2334 357 172 49 39 4008 172 13 389 46 5
4394 2691 172 4008 172 49 39 13 389 389 46 46 5
5 4394 2334 357 172 49 39 572 172 13 389 45 6
4394 2691 172 49 572 39 Repaired seating surfaces, rebuilt bonnet, repacked.
172 13 389 389 45 45 6
6 5
5 5
5 5
5 26 &
220 C-)
R
-4 35D TIP Ball ball
ATTACHMENT TYPE C 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR CRD Return CAD Supply CAD Supply Jet Pump Samp Jet Pump Samp Recirc Sample SBLC CAM Return V-17-053 V-17-052 SV-4332A SV-4332B SV-4331A SV-4331B SV-4594A SV-4595A SV-4594B SV-4595B CV-4639 CV-4640 V-26-009 V-26-008 SV-8105B 36 39A 39B 40D 40C 41 42 46F 48 50B 54 277 265 7
132 152 19 14 33 89 3027 33 532 5000 33 20 279 162 9
9 277 265 152 19 89 3027 5000 33 279 9
54 7
132 14 33 33 532 20 162 9
54 277 265 7
132 152 19 14 33 89 947 6
532 5000 33 20 279 162 9
9 277 265 152 19 89 947 5000 33 279 9
54 7
132 14 33 6
532 20 162 9
Replaced packing.
Rebuilt operator.
SV-8106B DW Drain Disch CV-3728 CV-3729 CAM Supply SV-8101A SV-8102A M
ATTACHMENT TYPE C 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 50D CAM Supply 50E CAM Supply 54 RBCCW Return 55 RBCCW Supply 56C CAM Supply 56D CAM Supply 205 Torus Exh Out 211A CAD Supply 211B CAD Supply SV-8105A SV-8106A SV-8103A SV-8104A MO-4841A MO-4841B SV-8101B SV-8102B SV-8103B SV-8104B CV-4300 CV-4301 CV-4357 CV-4309 SV-4333A SV-4333B SV-4334A 5
5 5
5 121 303 22 25 25 22 765 7930 96 98 5
5 5
5 121 303 25 25 8695 98 23 23 121 303 22 22 765 96 5
5 5
5 55 152 22 25 25 22 8560 496 96 98 19 SV-4334B 19 5
5 5
5 55 152 25 55 152 22 25 22 9056 4776 Repaired operator.
Repaired operator.
Ci Replaced T-seal, rebuilt operator.
Replaced T-seal, rebuilt operator.
Replaced valve.
98 96 23 23 19 19
0s 0
ATTACHMENT TYPE C 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 212 212 214 214 219 233 536 167 13082 704 506 617 403 10 18 55 50 48 7
5 5
5 233 536 13082 704 617 RCIC Exhaust V-24-008 V-24-023 RCIC Ex Vac BkrV-24-046 V-24-047 HPCI Exhaust V-22-017 V-22-016 HPCI Ex Vac BkrV-22-063 V-22-064 HPCI/RCIC ExhMO-2290B MO-2290A HPCI Cond Ret V-22-022 V-22-021 CAM Supply SV-8107A SV-8108A CAM Supply SV-8109A SV-8110A CAM Return SV-8109B SV-8110B CAM Supply SV-8107B SV-8108B 117 167 6541 506 403 220 536 167 628 895 506 157 160 30 18 55 50 48 7
5 5
5 5
18 48 5
5 220 536 628 895 160 30 55 50 7
5 110 167 314 506 157 15 18 48 5
5 Rebuilt valve.
Inspected internals.
Inspected internals.
Replaced packing.
Replaced packing, repaired operator.
Inspected internals.
Inspected internals.
10 55 50 7
5 222 229B 229C 229F 229G
-I C-,
=
z m z
-I I-.
0 ATTACHMENT TYPE C 1993 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 229H Pass Sam Ret SV-8772A SV-8772B 231 Vacuum BreakerCV-4304 20 19 989 20 989 19 495 20 20 19 19 17 17 9
V-43-169 231 Vacuum BreakerCV-4305 118 118 59 73 73 37 V-43-168 Replaced T-seal, rebuilt operator.
Replaced T-seal, rebuilt operator.
TOTAL TYPE C C-)
M z
162564 66097 59081 27670
01 ATTACHMENT TYPE B 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage TESTABLE X-1 X-2 X-4 X-6 X-35A X-35B X-35C X-35D X-53 X-58A X-58B GASKETS Personnel Lock Equip Door Equipment Access Hatch Drywell Head Access Hatch CRD Removal Hatch TIP Drive TIP Drive TIP Drive TIP Purge Line Spare Drywell Head Stabilizer Access Port Stabilizer Access Port 0
0 0
0 0
0 0
0 0
21 11032 0
0 0
0 2645 0
0 0
0 0
0 86 0
2/28/92 4/18/92 4/16/92 4/18/92 3/09/92 3/09/92 3/09/92 3/09/92 2/28/92 4/16/92 4/08/92 3/17/92 C-,
co
ATTACHMENT TYPE B 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage TESTABLE GASKETS X-58C Stabilizer Access Port 0
0 3/17/92 X-58D Stabilizer Access Port 0
0 3/17/92 X-58E Stabilizer Access Port 0
0 3/16/92 X-58F Stabilizer Access Port 0
0 3/16/92 X-58G Stabilizer Access Port 0
0 3/16/92 X-58H Stabilizer Access Port 0
0 3/16/92 N-200A South Torus Access Hatch 0
102 3/19/92 N-200B North Torus Access Hatch 0
0 4/11/92 ELECTRICAL PENETRATIONS X-100B Neutron Monitoring 103 0
3/06/92 X-100C Neutron Monitoring 103 0
3/06/92 X-100E Neutron Monitoring 0
0 3/13/92 X-100F Neutron Monitoring 0
0 3/14/92 X-100G RPV Vibration Monitoring 0
0 3/12/92
ATTACHMENT TYPE B 1992 LOCAL LEAKAGE RATE TEST DATA
.(SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage X-101A Recirc Pump Power 0
0 3/13/92 X-101C Recirc Pump Power 103 103 3/09/92 X-103 Thermocouples 0
0 3/14/92 X-104A CRD Rod Position Indication 0
0 3/14/92 X-104B CRD Rod Position Indication 0
0 3/14/92 co X-104C CRD Rod Position Indication 103 103 3/06/92 X-104D CRD Rod Position Indication 103 103 3/06/92 X-105B Power and Control 0
0 3/13/92 X-105D Power and Control 20 20 3/09/92 X-106A Power and Control 0
0 3/13/92 X-106C Power and Control 0
0 3/09/92 N-230B Vacuum Breaker Cables 17 17 3/06/92 SHAFT STEM SEALS X-26 Drywell Purge Supply, CV-4307 17 17 3/01/92 N-220 Torus Purge Supply, CV-4308 102 102 3/01/92
ATTACHMENT TYPE B 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage FLANGE O-RINGS X-25 Drywell Purge Outlet CV-4302 17 17 2/29/92 X-26 Drywell Purge Outlet CV-4307 0
0 3/01/92 N-205 Torus Purge Outlet CV-4300 681 681 2/29/92 N-213A South Torus Drain Line Flange 102 102 3/14/92 N-213B North Torus Drain Line Flange 92 92 3/02/92 N-220 Torus Purge Supply CV-4308 102 102 3/01/92 N-231 RB/Torus Vacuum Breaker CV-4304 0
0 3/04/92 N-231 RB/Torus Vacuum Breaker CV-4305 17 17 3/17/92 VALVE BONNETS X-39A Drywell Spray, MO-2000 103 103 3/09/92 N-211B Torus Spray, MO-2006 102 102 3/06/92 X-39B Drywell Spray, MO-1902 710 710 3/16/92 N-211A Torus Spray, MO-1933 102 102 3/16/92
0 ATTACHMENT TYPE B 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage EXPANSION X-7A X-7B X-7C X-7D X-9A X-9B X-10 X-11 X-12 X-13A X-13B X-15 X-16A X-16B BELLOWS Main Steam Line Main Steam Line Main Steam Line Main Steam Line Reactor Feedwater Reactor Feedwater RCIC Steam Supply HPCI Steam Supply RHR Shutdown Cooling Supply A RHR LPCI Inject B RHR LPCI Inject RWCU Supply A Core Spray Discharge B Core Spray Discharge 115 90 29 33 61 45 126 17 0
0 72 102 102 0
115 0
29 33 61 45 0
17 0
0 0
0 102 0
-I 00 3/06/92 4/07/92 3/06/92 3/06/92 3/06/92 3/06/92 4/07/92 3/06/92 3/05/92 4/07/92 4/07/92 4/09/92 3/13/92 4/07/92
0 ATTACHMENT TYPE B 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage EXPANSION X-17 N-201A N-201B N-201C N-201D N-201E N-201G N-201F N-201H N-213A N-213A N-213B N-213B BELLOWS RHR Head Spray Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer Drywell to Torus Downcomer South Torus Inbd Drain Line South Torus Outbd Drain Line North Torus Inbd Drain Line North Torus Outbd Drain Line 102 92 92 92 92 92 92 102 102 102 16 102 102 102 92 92 92 92 92 92 0
0 102 16 0
3/14/92 3/02/92 3/02/92 3/02/92 3/02/92 3/02/92 3/02/92 4/08/92 4/08/92 3/14/92 3/14/92 4/08/92 0
4/08/92 15724 6500
-I I', co TOTAL TYPE B
ATTACHMENT TYPE C 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 7A Main Steam CV-4412 CV-4413 7B Main Steam CV-4415 CV-4416 7C Main Steam CV-4418 CV-4419 7D Main Steam CV-4420 CV-4421 29898 5774 1198 1198 29898 1198 5073 5073 5774 1198 1247 1247 8051 8051 554 554 1198 1198 188 188 2548 2548 554 1198 554 Machined seat, bore.
Machined seat, bore, replaced stem, disc.
1198 188 188 32 2548 32 Machined seat, bore, replaced stem, disc.
Replaced stem.
Machined seat, bore, replaced stem, disc.
2548 8
Steam Drain 9A Feedwater MO-4423 MO-4424 V-14-03 MO-4441 MO-2312 718 705 718 718 6917 705 718 6917 0
705 705 0
1115 1115 1013 1013 Removed operator, rebuilt valve.
Overhauled operator.
C-,,
ATTACHMENT TYPE C 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 9B Feedwater 10 RCIC Cond Rtn 10 RCIC Steam 11 HPCI Steam V-14-01 MO-2740 MO-2512 MO-4442 CV-2410 CV-2411 MO-2400 MO-2401 MO-2238 MO-2239 11 HPCI Cond Rtn CV-2211 CV-2212 15 RWCU MO-2700 MO-2701 16A Core Spray MO-2117 MO-2115 16B Core Spray MO-2137 MO-2135 19 Drywell Drain CV-3704 CV-3705 408217 408217 2043 102 102 102 92 2137 2137 750 360 101 102 590 2299 102 102 54 710 17 687 750 2043 102 92 360 102 101 2299 102 710 687 590 102 54 17 507 1221 507 1221 102 102 Removed operator, rebuilt valve.
Overhauled operator.
102 102 1100 2645 1100 2645 750 360 101 102 2128 2299 62 106 54 163 17 603 750 Replaced packing, Overhauled operator.
Overhauled operator.
360 102 101 2299 2128 106 163 Overhauled operator.
62 54 Overhauled operator.
687 17 z
ATTACHMENT TYPE C 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 20 21 22 &
229A 23A 23B 24A 24B 25 102 102 0
1368 662 662 2289 713 92 1175 662 102 0
2030 Demin Water V-09-1 11 V-09-065 Service Air V-30-287 Blind Flange N2 Comp Disch V-43-214 CV-4371C CV-4371A DW Cool Supply CV-5718A V-57-077 DW Cool Supply CV-5718B V-57-078 DW Cool Return CV-5704A V-57-075 DW Cool Return CV-5704B V-57-076 DW Purge Out CV-4302 CV-4303 CV-4310 102 0
662 102 102 0
1368 662 662 2289 713 92 1175 662 2289 713 92 1175 399 68 2289 713 92 1175 730 102 0
2030 2289 713 92 1175 730 102 0
662 2289 713 92 1175 399 I
00 68
ATTACHMENT TYPE C 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 26 &
220 DW Purge Sup CV-4306 CV-4307 CV-4308 2634 2634 1317 2634 2634 1317 26&
DW & Torus M/UCV-4311 220 32 DN2 Comp Suc 32E Recirc A Seal 32F Recirc B Seal CV-4312 CV-4313 CV-4378A CV-4378B V-17-096 CV-1804A V-17-083 CV-1804B 35A TIP Check check 35B TIP Ball 35C TIP Ball ball ball 6917 1459 369 86 17 123 112 86 481 710 43 0
6917 1828 86 17 123 481 710 112 86 710 43 43 0
0 0
0 0
0 0
0 6917 1828 86 17 123 117 6917 1459 369 86 17 123 112 86 481 710 45 0
2:
481 86 710 710 45 45 0
0 35D TIP Ball ball
ATTACHMENT TYPE C 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR CRD Return CAD Supply CAD Supply Jet Pump Samp Jet Pump Samp, Recirc Sample SBLC CAM Return V-17-053 V-17-052 SV-4332A SV-4332B SV-4331A SV-4331B SV-4594A SV-4595A SV-4594B SV-4595B CV-4640 CV-4639 V-26-009 V-26-008 SV-8105B SV-8106B 36 39A 39B 40D 40C 41 42 46F 48 50B 479 112 684 681 684 166 102 102 94 0
26 573 3039 102 102 102 102 0
0 479 684 684 102 94 26 3039 102 102 0
112 681 166 102 0
13 573 102 102 0
479 112 684 681 684 166 102 102 94 0
26 18 573 3039 102 102 102 102 0
0 479 684 684 102 94 26 3039 102 102 0
112 681 166 102 0
18 573 102 102 0
--I
=
0 z CO, Rebuilt operator DW Drain Disch CV-3728 CV-3729 CAM Supply SV-8101A SV-8102A
ATTACHMENT TYPE C 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 50D CAM Supply SV-8105A SV-8106A 50E CAM Supply SV-8103A SV-8104A 54 RBCCW Return MO-4841A 55 RBCCW Supply MO-4841B 56C CAM Supply SV-8101B SV-8102B 56D CAM Supply SV-8103B SV-8104B 205 Torus Exh Out CV-4300 CV-4301 CV-4357 CV-4309 211A CAD Supply SV-4333A SV-4333B 211B CAD Supply SV-4334A SV-4334B 0
0 0
0 687 684 0
0 132 137 684 8647 77 75 507 92 0
0 0
0 687 684 0
137 9331 77 507 687 684 0
132 684 75 92 0
0 0
0 88 700 0
0 132 137 0
8647 77 75 507 92 0
0 0
0 88 700 0
88 700 0
Repaired operator.
Repaired operator.
137 132 8647 0
Installed hard pipe vent.
77 75 507 92 MI M
M
0 ATTACHMENT TYPE C 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM) 09 Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 212 212 214 214 219 53 540 402 6523 1064 916 710 659 9290 0
0 31 31 0
17 17 0
53 540 6523 1064 710 RCIC Exhaust V-24-008 V-24-023 RCIC Ex Vac BkrV-24-046 V-24-047 HPCI Exhaust V-22-017 V-22-016 HPCI Ex Vac BkrV-22-063 V-22-064 HPCI/RCIC ExhMO-2290B MO-2290A HPCI Cond Ret V-22-022 V-22-021 CAM Supply SV-8107A SV-8108A CAM Supply SV-8109A SV-81 10A CAM Return SV-8109B SV-8110B CAM Supply SV-8107B SV-8108B 27 402 3262 916 659 53 540 175 6523 1064 916 710 659 461 0
0 31 31 0
17 17 0
4645 0
31 0
0 53 540 6523 1064 710 461 0
31 17 17 27 175 3262 916 659 231 0
31 0
0 Inspected internals.
Inspected internals.
Rebuilt.
9290 0
31 17 17 222 229B 229C 229F 229G
-c.
CO
ATTACHMENT TYPE C 1992 LOCAL LEAKAGE RATE TEST DATA (SCCM)
Pen System Name Equipment As-Found As-Found As-Found As-Left As-Left As-Left Remarks No.
Leakage MXPLR MNPLR Leakage MXPLR MNPLR 229H Pass Sam Ret SV-8772A SV-8772B 231 Vacuum BreakerCV-4304 V-43-169 231 Vacuum BreakerCV-4305 TOTAL TYPE C 92 92 659 0
92 659 0
520817 92 330 0
39764 92 92 659 0
92 659 0
58145 92 330 0
25624 co
ATTACHMENT DRYWELL AIRLOCK TEST DATA (SCCM)
Pen System Name As-Found As-Left Date Remarks No.
Leakage Leakage TESTABLE GASKETS X-1 Personnel Airlock 9722 8413 6540 6049 8869 6413 9722 8413 6540 6049 8869 6413 09/20/90 12/14/90 06/29/91 04/22/92 01/28/93 09/19/93
=
z rri
MID-CYCLE LOCAL LEAKAGE ATTACHMENT RATE TESTING DATA FOR (SCCM)
TESTING SINCE RFO-10 Pen System Name Equipment As-Found As-Left Date Remarks No.
Leakage Leakage Main Steam Feedwater HPCI Steam CV4418 CV4419 V14-003 M02239 40592 610 295 0
6/29/91 Replaced disc Machined seat 610 6/24/91 295 6/27/91 16 8/20/92 Replaced stem Repacked 0
7C 9A 11A a
aI